This is a technical plan and profile drawing for wastewater infrastructure at Death Valley National Park. The document shows the Cow Creek Wastewater system serving the Coyote Loop area, with sheet C5.33 depicting gravity sewer line design and layout.

The project includes installation of approximately 370 linear feet of 8-inch PVC SDR 35 sanitary sewer pipe at varying slopes (0.41% to 1.40%), four new sanitary sewer manholes (SSMH-CC-166, SSMH-CC-172, SSMH-CC-173, and SSMH-CC-174), and an 80-linear-foot 4-inch SDR 35 sanitary sewer service line with minimum 2% slope. The gravity line extends from stations CS 200+82.31 through CS 205+67.55, with pipe invert elevations ranging from 168.38 to 171.66 feet and rim elevations from 176.33 to 183.57 feet. The system accommodates proposed water service crossings at stations CS 202+76.27 and CS 203+14.64, a proposed water main crossing at CS 203+82.49, an existing water main crossing at CS 204+00.61, and an existing sewer main crossing at CS 205+67.55. Additional infrastructure includes a proposed Coyote Loop lift station building (referenced on architectural sheets) with minimum 3-foot cover depth, replacement of existing cleanouts, and a 50-foot disturbance limit. The drawing was designed and technically reviewed by T. Francis and M. Whelehon, dated January 17, 2025, under PMIS/PKG 178069.

View the file

Other files

File Type Posted
B09_Amd11_-_B08_Attach3_-_WD_CA20260020_Mod2_0011.pdf PDF
Sol_140P2025R0082_Amd_0011.pdf PDF
B09_Amd10_-_QR55_Attach_Drawing_01-C4_42_Jan2026_0010.pdf PDF
B09_Amd10_-_QR55_Attach_Drawing_01-C4_38_Jan2026_0010.pdf PDF
B09_Amd10_-_QR55_Attach_Drawing_01-C4_40_Jan2026_0010.pdf PDF
B09_Amd10_QR_Tracker_-_DEVA_318717_Final_0010.xlsx XLSX spreadsheet
B09_Amd10_-_QR55_Attach_Drawing_01-C4_39_Jan2026_0010.pdf PDF
B09_Amd10_-_QR55_Attach_Drawing_00-C8_27_Jan2026_0010.pdf PDF
B09_Amd10_-_QR86_Attach_Drawing_C1_40_0010.pdf PDF
B09_Amd10_-_Drawing_G1_22_0010.pdf PDF
B09_Amd10_-_QR86_Attach_Drawing_C1_40B_0010.pdf PDF
Sol_140P2025R0082_Amd_0010.pdf PDF
B09_Amd10_-_B08_Attach4_-_DetailedContractPriceSchedule_0010.xlsx XLSX spreadsheet
B09_Amd10_-_Drawing_G1_2_0010.pdf PDF
B09_Amd10_-_Drawing_Coversheet_00_DEVA_318717_Jan2026x_0010.pdf PDF
B09_Amd10_-_Drawing_G1_21_0010.pdf PDF
Sol_140P2025R0082_Amd_0009.pdf PDF
B09_Amd8_-_Drawing_02-C5_29_Jan2026_0008.pdf PDF
B09_Amd8_-_Spec_33_14_19_-_VALVES___HYDRANTS_FOR_WATER_UTILITY_SERVICE_0008.pdf PDF
B09_Amd8_-_Drawing_02-G1_16_Dec2025_0008.pdf PDF
B09_Amd8_-_Spec_08_33_22_-_ALUMINUM_ROLLING_OVERHEAD_DOORS_0008.pdf PDF
B09_Amd8_-_Drawing_01-C1_29_Jan2026_0008.pdf PDF
B09_Amd8_-_QR22_Attach_Drawing_00-C7_1_Jan2026_0008.pdf PDF
B09_Amd8_-_Drawing_02-C5_25_Jan2026_0008.pdf PDF
B09_Amd8_-_Drawing_00-C8_30_Dec2025_0008.pdf PDF
B09_Amd8_-_Drawing_01-C4_42_Jan2026_0008.pdf PDF
B09_Amd8_-_Drawing_01-C3_1_Dec2025_0008.pdf PDF
B09_Amd8_-_Drawing_00-C3_20_Dec2025_0008.pdf PDF
B09_Amd8_-_Spec_33_32_00_-_WASTEWATER_PUMPING_STATIONS_0008.pdf PDF
B09_Amd8_-_Spec_33_31_11_-_GRAVITY_SEWER_PIPELINE___MANHOLE_INSTALLATION_0008.pdf PDF
B09_Amd8_QR_Tracker_-_DEVA_318717_0008.xlsx XLSX spreadsheet
B09_Amd8_-_Drawing_Coversheet_00_DEVA_318717_Jan2026_0008.pdf PDF
Sol_140P2025R0082_Amd_0008.pdf PDF
B09_Amd8_-_Drawing_01-C1_31_Jan2026_0008.pdf PDF
B09_Amd8_-_Drawing_02-C6_7_Jan2026_0008.pdf PDF
B09_Amd8_-_Drawing_00-C3_15_Dec2025_0008.pdf PDF
B09_Amd8_-_Drawing_00-G1_2_Jan2026_0008.pdf PDF
B09_Amd8_-_Drawing_02-C7_5_Dec2025_0008.pdf PDF
B09_Amd8_-_Spec_33_11_13_-_POTABLE_WATER_SUPPLY_WELLS_0008.pdf PDF
B09_Amd8_-_Drawing_00-C3_18_Dec2025_0008.pdf PDF
B09_Amd8_-_Drawing_01-C1_42_Jan2026_0008.pdf PDF
B09_Amd8_-_QR56_Attach_Drawing_02-C2_20_Dec2025_0008.pdf PDF
B09_Amd8_-_Spec_33_31_05_-_MANHOLE_LINING___REHABILITATION_0008.pdf PDF
B09_Amd8_-_Drawing_01-G1_15_Jan2026_0008.pdf PDF
B09_Amd8_-_QR56_Attach_Drawing_02-C2_18_Dec2025_0008.pdf PDF
B09_Amd8_-_Drawing_01-C1_67_Jan2026_0008.pdf PDF
B09_Amd8_-_Spec_46_33_11_-_CHEMICAL_FEED_-_LIQUID_SYSTEMS_0008.pdf PDF
B09_Amd8_-_Drawing_02-C2_22_Jan2026_0008.pdf PDF
B09_Amd8_-_Drawing_02-X1_2_Jan2026_0008.pdf PDF
B09_Amd8_-_QR22_Attach_Drawing_02-C5_64_Jan2026_0008.pdf PDF
Show 40 more

Latest 50 of 109 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ES(B)

ES(B)

ES(B)

ES(B)

ES(B)

ES(B)

ES(B)

ES(B)

ES

(B

ES

(B

ES

(B

ES

(B

ES

(B

ES

(B

ES

(B

ES

(B

ES

(B

ES

(B

ES

(B

ES

(B

ES

(B

ES

(B

ES

(B

ES

(B

ES

(B

ES

(B

ES(B)

ES(B)

ES(B)

ES(B)

ES(B)

ES

(B

M H

S

S

S

ES(B)

ES(B)

ES(B)

ES(B)

ES

(B

ES

(B

ES(B)

ES(B)

ES(B)

ES(B)

ES(D)

ES(D)

U G

P( B)

UG

P(

B)

U G

P( B)

U G

P( B)

UG

P(

B)

UG

P(

B)

UG

P(

B)

U G

P( B)

UG

P(

B)

UG

P(

B)

ES(D)

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

AC

AC

AC

AC

AC

AC

AC

IC

V

IC

V

UB

UB

UB

AC

AC

E

E

EM

D

YH

UG

P(

B)

UG

P(

B)

UG

P(

B)

U G

P( B)

U G

P( B)

U G

P( B)

UGP(B)

UGP(B)

EW

(B

EW

(B

EW

(B

EW

(B

EW

(B

EW

(B

EW

(B

EW

(B

EW

(B

EW

(B

EW(B)

EW(B)

EW(B)

EW(B)

EW(B)

EW(B)

EW

(B)

EW

(B)

EW

(B)

EW

(B)

EW

(B)

EW

(B)

EW

(B)

EW(B

EW(B

EW

(B

EW

(B

UGP(B)

UGP(B

)W M

T

T

D

YH

E

EM

E T

W V

W V

W V

W V

EW(B)

EW(B)

EW(B)

COYOTE LO

OP

SK

YL

IN

E

DR

IV

E

CCQ335

CCQ336

CCQ34

C C

Q

C C

Q

C al

Tr an s

C al

Tr an s

UGP(B)

UG

P(

B)

UG

P(

B)

UGP(B

UGP(B)

UGP(

B)

WS

WS

WS

W

W

W

W

W 6''

W 6''

W 6''

W 6''

W 6''

W 6'

W 6'

W 6'

FS

W S

W S

W S

W S

W S

W S

W S

W S

W S

W S

W S

WS

WS

WSGV

WS

WS

WS

WS

GV

WS

WS

WS

GV

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

CS 200+00

CS

+0

CS

+0

CS 203+00

CS 204+00

CS 205+00

CS 211+00

185 185

SS

SS

SS

SS

SS

S

S

CIPP

CIPP

SSMH-CC-150

STA = CS 200+00.00

RIM = 176.06

E 8" INV. IN = 170.98

SE 8" INV. IN = 166.34

W 8" INV. OUT = 170.82

SSMH-CC-173

STA = CS 202+02.91

RIM = 183.57

S 8" INV. IN = 170.28

W 8" INV. OUT = 170.17

SSMH-CC-166

STA = CS 204+52.02

RIM = 178.76

SW 8" INV. IN = 171.66

N 8" INV. OUT = 171.56

SSMH-CC-172

STA = CS 203+22.40

RIM = 181.30

S 8" INV. IN = 170.87

N 8" INV. OUT = 170.77

SSMH-CC-174

STA = CS 200+82.31

RIM = 176.33

E 8" INV. IN = 168.48

NW 8" INV. OUT = 168.38

EXISTING WATER MAIN CROSSING

STA: CS 200+20.64

PROPOSED WATER MAIN CROSSING

STA: CS 200+22.40

UNDERGROUND

POWER CROSSING

STA: CS 200+27.64

PROPOSED WATER SERVICE CROSSING

STA: CS 202+76.27

PROPOSED WATER SERVICE CROSSING

STA: CS 203+14.64

PROPOSED WATER MAIN CROSSING

STA: CS 203+82.49

EXISTING WATER MAIN CROSSING

STA: CS 204+00.61

EXISTING SEWER MAIN CROSSING

STA: CS 205+67.55

SEWER SERVICE CONNECTION

STA: CS 201+11.09

SEWER SERVICE CONNECTION

STA: CS 205+20.52

CS 200+00

6.

0.

6.

0.

5.

1.

5.

1.

6.

2.

CS 201+00

6.

2.

7.

2.

6.

2.

6.

2.

0.

2.

CS 202+00

3.

2.

4.

2.

5.

2.

5.

2.

5.

2.

CS 203+00

4.

2.

1.

2.

1.

2.

1.

2.

1.

2.

CS 204+00

0.

2.

0.

2.

9.

2.

8.

2.

7.

2.

CS 205+00

7.

2.

82' OF 8" PVC SDR 35 @ 2.47% 121' OF 8" PVC SDR 35 @ 1.40% 119' OF 8" PVC SDR 35 @ 0.41% 130' OF 8" PVC SDR 35 @ 0.53%

SS

M

H -C

C -1

ST

A

C S

4+

.0

R

IM

.7

N

" I N

V.

O

U T

1.

SW

" I N

V.

IN

.6

SS

M

H -C

C -1

ST

A

C S

3+

.4

R

IM

.3

N

" I N

V.

O

U T

0.

S 8"

IN

V.

IN

.8

SS

M

H -C

C -1

ST

A

C S

2+

.9

R

IM

.5

W

" I N

V.

O

U T

0.

S 8"

IN

V.

IN

.2

SS

M

H -C

C -1

ST

A

C S

0+

.0

R

IM

.0

W

" I N

V.

O

U T

0.

E 8"

IN

V.

IN

.9

SE

" I N

V.

IN

.3

EX

IS

TI

N

G W

AT

ER

M

AI

N C

R O

SS

IN

G

ST

A:

C

S

0+

.6

T.

O

.P . E

LE

V:

2.

PR

O

PO

SE

D W

AT

ER

M

AI

N C

R O

SS

IN

G

ST

A:

C

S

0+

.4

T.

O

.P . E

LE

V:

7.

U N

D

ER

G R

O U

N D

PO

W

ER

C

R O

SS

IN

G

ST

A:

C

S

0+

.6

T.

O

.P . E

LE

V:

7.

PR

O

PO

SE

D W

AT

ER

SE

R

VI

C

E C

R O

SS

IN

G

ST

A:

C

S

2+

.2

T.

O

.P . E

LE

V:

1.

PR

O

PO

SE

D W

AT

ER

M

AI

N C

R O

SS

IN

G

ST

A:

C

S

3+

.4

T.

O

.P . E

LE

V:

2.

EX

IS

TI

N

G W

AT

ER

M

AI

N C

R O

SS

IN

G

ST

A:

C

S

4+

.6

T.

O

.P . E

LE

V:

1.

PR

O

PO

SE

D W

AT

ER

SE

R

VI

C

E C

R O

SS

IN

G

ST

A:

C

S

3+

.6

T.

O

.P . E

LE

V:

1.

SS

M

H -C

C -1

ST

A

C S

0+

.3

R

IM

.3

N W

" I

N V.

O U

T

8.

E

8"

IN

V.

IN

.4

SE

W

ER

SE

R

VI

C E

C O

N N

EC

TI

O N

ST

A:

C S

1+

.0

T.

O .P

. E

LE

V:

9.

SKYLINE DRIVE

COYOTE LOOP

C O

YO

TE LO

O P

C O

YO

TE LO

O P

C O

YO

TE

L O

O P

SKYLINE DRIVE

SKYLINE DRIVE

OLD GHOST ROAD

OLD GHOST ROAD

OLD GHOST ROAD

OLD GHOST ROAD

NEVARES DRIVE

SK

YL

IN

E

DRIV

E

O

LD

G H

O

ST

R O

AD

SKYLIN

E DRIVE

ACCESS ROAD

AC

CE

SS

R

O

AD

SKYLINE DRIVE

SKYLINE DRIVE

C O

YO

TE LO

O P

SKYLINE DRIVE SKYLINE DRIVE

NEVARES DRIVE

OLD GHOST ROAD

CC

Q

C C

Q

C C

Q

C C

Q

C C

Q

C C

Q

C

C Q

C C

Q

CC

Q

NHA

CHP

CCQ139

CCQ138

CCQ140

CCQ205

CCQ206

CCQ214

CCQ323

CCQ209

CalTrans

CalTrans

CCQ123

CCQ121

CCQ122

CCQ359

CCQ126

CCQ127

CCQ210

TEACHERAGE

CCQ213

CC69

CCQ128

CCQ129 CCQ358

CCQ328

CCQ329

CCQ33

C C

Q

CCQ357

CCQ110

CCQ211

CCQ212

CCQ68

CCQ1

CCQ324

CCQ34

CC

Q2

CCQ220

CalTrans

CalTrans

CalTrans

PRV

ARV

ARV

ARV

AR

V

GV

GV

GV

GV

GV

GV

GV

GV

GV

GV

GV

GV

BV

ARV

GV

GV

GV

GV

GV

GV

GV

GV

GV

GV

GV

GV GV

GV

GV

GV

GV

GV

GV

GV

GV

GV

ARV

GV

DATE:

DESIGNED:

TECH. REVIEW:

SUB SHEET NO.

PMIS/PKG NO.

DRAWING NO.

SHEET

OF

TITLE OF SHEET

COW CREEK WASTEWATER

PLAN & PROFILE

COYOTE LOOP GRAVITY

178069

254 513

T. FRANCIS

T. FRANCIS

M. WHELEHON

1.17.2025

DEATH VALLEY

NATIONAL PARK

318717 02-

C5.33

HORIZ.

VERT.

PLAN

PROFILE 20 0 20 40

SCALE OF FEET

10 0 10 20

KEY MAP

NTS

APPROXIMATE EXISTING

GROUND SURFACE

COYOTE LOOP

SEE SHEET C5.26

PROPOSED COYOTE LOOP

LIFT STATION BUILDING, SEE

ARCHITECTURAL SHEETS

REPLACE EXISTING CLEANOUT

DISTURBANCE

LIMIT 50'

PROTECT TREE IN PLACE

(TYP. ALL TREES WITHIN

DISTURBANCE LIMIT UNLESS

CALLED OUT ON SHEET X1.1)

5.02' COVER

(MIN. COVER = 3.00')

B C3.15

D C3.12

SEE SHEET C5.34

REMOVE TREE,

SEE SHEET X1.1

95 LF 4" SDR 35 SANITARY

SEWER SERVICE MIN. 2% SLOPE

80 LF 4" SDR 35 SANITARY

SEWER SERVICE MIN. 2% SLOPE

REHABILITATE

MANHOLE

INSTALL NEW

MANHOLE

INSTALL NEW

MANHOLE

INSTALL NEW

MANHOLE

INSTALL NEW

MANHOLE

C C7.0

D C7.0

Sheets and Views
Sheet - (38)