B09_Amd8_-_Drawing_01-C1_29_Jan2026_0008.pdf

PDF 214 KB Posted

Attached to
DEVA 318717 - Rehab Furnace & Cow Creeks WTP/WWTP
Solicitation number
140P2025R0082
Issued by

About this file

This is a technical plan and profile drawing for the Furnace Creek Water infrastructure project at Death Valley National Park in California. The drawing depicts the South Alignment of an 8-inch HDPE DR 11 water main installation along Death Valley Scenic Byway (CA SR-190) near Greenland Boulevard. The plan view shows the horizontal layout of the proposed water main with multiple utility crossings and appurtenances, while the profile view illustrates the vertical alignment and depth of the pipeline installation with a minimum cover of 2.50 feet.

The drawing includes detailed specifications for eight major components along the alignment: two 8-inch gate valves (at stations FW 173+04.41 and FW 173+24.85), an air release valve (at station FW 172+23.47), a 90-degree bend (at station FW 172+26.47), an 8-inch by 8-inch tee (at station FW 173+08.33), a blowoff valve (at station FW 173+14.92), another 90-degree bend (at station FW 173+17.84), and two existing irrigation line crossings (at stations FW 174+39.81 and FW 174+49.81). The alignment also accommodates two existing underground telephone line crossings at stations FW 174+77.90 and FW 174+99.83. The drawing was prepared by L. Graef, technically reviewed by M. Whelehon, and dated January 17, 2025, as Sheet 54 of 513 in the overall project documentation (PMIS/PKG No. 143 178069, Drawing No. C1.29).

View the file

Other files

File Type Posted
B09_Amd11_-_B08_Attach3_-_WD_CA20260020_Mod2_0011.pdf PDF
Sol_140P2025R0082_Amd_0011.pdf PDF
B09_Amd10_-_QR55_Attach_Drawing_01-C4_42_Jan2026_0010.pdf PDF
B09_Amd10_-_QR55_Attach_Drawing_01-C4_38_Jan2026_0010.pdf PDF
B09_Amd10_-_QR55_Attach_Drawing_01-C4_40_Jan2026_0010.pdf PDF
B09_Amd10_QR_Tracker_-_DEVA_318717_Final_0010.xlsx XLSX spreadsheet
B09_Amd10_-_QR55_Attach_Drawing_01-C4_39_Jan2026_0010.pdf PDF
B09_Amd10_-_QR55_Attach_Drawing_00-C8_27_Jan2026_0010.pdf PDF
B09_Amd10_-_QR86_Attach_Drawing_C1_40_0010.pdf PDF
B09_Amd10_-_Drawing_G1_22_0010.pdf PDF
B09_Amd10_-_QR86_Attach_Drawing_C1_40B_0010.pdf PDF
Sol_140P2025R0082_Amd_0010.pdf PDF
B09_Amd10_-_B08_Attach4_-_DetailedContractPriceSchedule_0010.xlsx XLSX spreadsheet
B09_Amd10_-_Drawing_G1_2_0010.pdf PDF
B09_Amd10_-_Drawing_Coversheet_00_DEVA_318717_Jan2026x_0010.pdf PDF
B09_Amd10_-_Drawing_G1_21_0010.pdf PDF
Sol_140P2025R0082_Amd_0009.pdf PDF
B09_Amd8_-_Drawing_02-C5_29_Jan2026_0008.pdf PDF
B09_Amd8_-_Spec_33_14_19_-_VALVES___HYDRANTS_FOR_WATER_UTILITY_SERVICE_0008.pdf PDF
B09_Amd8_-_Drawing_02-G1_16_Dec2025_0008.pdf PDF
B09_Amd8_-_Spec_08_33_22_-_ALUMINUM_ROLLING_OVERHEAD_DOORS_0008.pdf PDF
B09_Amd8_-_QR22_Attach_Drawing_00-C7_1_Jan2026_0008.pdf PDF
B09_Amd8_-_Drawing_02-C5_25_Jan2026_0008.pdf PDF
B09_Amd8_-_Drawing_00-C8_30_Dec2025_0008.pdf PDF
B09_Amd8_-_Drawing_01-C4_42_Jan2026_0008.pdf PDF
B09_Amd8_-_Drawing_01-C3_1_Dec2025_0008.pdf PDF
B09_Amd8_-_Drawing_00-C3_20_Dec2025_0008.pdf PDF
B09_Amd8_-_Spec_33_32_00_-_WASTEWATER_PUMPING_STATIONS_0008.pdf PDF
B09_Amd8_-_Spec_33_31_11_-_GRAVITY_SEWER_PIPELINE___MANHOLE_INSTALLATION_0008.pdf PDF
B09_Amd8_QR_Tracker_-_DEVA_318717_0008.xlsx XLSX spreadsheet
B09_Amd8_-_Drawing_Coversheet_00_DEVA_318717_Jan2026_0008.pdf PDF
Sol_140P2025R0082_Amd_0008.pdf PDF
B09_Amd8_-_Drawing_01-C1_31_Jan2026_0008.pdf PDF
B09_Amd8_-_Drawing_02-C6_7_Jan2026_0008.pdf PDF
B09_Amd8_-_Drawing_00-C3_15_Dec2025_0008.pdf PDF
B09_Amd8_-_Drawing_00-G1_2_Jan2026_0008.pdf PDF
B09_Amd8_-_Drawing_02-C7_5_Dec2025_0008.pdf PDF
B09_Amd8_-_Spec_33_11_13_-_POTABLE_WATER_SUPPLY_WELLS_0008.pdf PDF
B09_Amd8_-_Drawing_00-C3_18_Dec2025_0008.pdf PDF
B09_Amd8_-_Drawing_02-C5_33_Jan2026_0008.pdf PDF
B09_Amd8_-_Drawing_01-C1_42_Jan2026_0008.pdf PDF
B09_Amd8_-_QR56_Attach_Drawing_02-C2_20_Dec2025_0008.pdf PDF
B09_Amd8_-_Spec_33_31_05_-_MANHOLE_LINING___REHABILITATION_0008.pdf PDF
B09_Amd8_-_Drawing_01-G1_15_Jan2026_0008.pdf PDF
B09_Amd8_-_QR56_Attach_Drawing_02-C2_18_Dec2025_0008.pdf PDF
B09_Amd8_-_Drawing_01-C1_67_Jan2026_0008.pdf PDF
B09_Amd8_-_Spec_46_33_11_-_CHEMICAL_FEED_-_LIQUID_SYSTEMS_0008.pdf PDF
B09_Amd8_-_Drawing_02-C2_22_Jan2026_0008.pdf PDF
B09_Amd8_-_Drawing_02-X1_2_Jan2026_0008.pdf PDF
B09_Amd8_-_QR22_Attach_Drawing_02-C5_64_Jan2026_0008.pdf PDF
Show 40 more

Latest 50 of 109 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

E W

(B

E W

(B

E W

(B

E W

(B

E W

(B

E W

(B

E W

(B

E W

(B

E W

(B

T

T

E

IR

R (D

E

IR

R (D

E

IR

R (D

E

IR

R (D

E

IR

R (D

E

IR

R (D

E

IR

R (D

E

IR

R (D

E

IR

R (D

E

IR

R (D

E

IR

R (D

E

IR

R (D

E

IR

R (D

E

IR

R (D

U

G T(

B

U G

T( B

U G

T( B

U G

T( B

U G

T( B

UGT(B)

UGT(B)

T

TT

FO(D)

FO(D)

FO(D)

FO(D)

FO(D)

8'' HDPE TEE

STA:FW 173+08.33

UNDERGROUND TELEPHONE

LINE CROSSING

STA:FW 174+77.90

UNDERGROUND TELEPHONE

LINE CROSSING

STA:FW 174+99.83

90 DEG. BEND

STA:FW 173+17.84

BLOWOFF VALVE

STA:FW 173+14.92

90 DEG. BEND

STA:FW 172+26.47

-169

-168

-1

-1

-166

-166

-166

-1

-164

8'' GATE VALVE

STA:FW 173+24.85

8'' GATE VALVE

STA:FW 171+00.00

W 8''

W 8''

W 8''

W 8''

W 8''

W 8''

W 8''

W 8''

W 8''

W 8''

W 8''

W 8''

ARV

W

GV

GV

GV

FO(D)

FO(D)

FO(D)

FO(D)

FO(D)

WS

WS

WS

WS

G V

FW 169+00

FW 170+00

FW 171+00

FW 172+00

F W

173+

FW 174+00

FW 175+00

FW 176+00

AIR RELEASE VALVE

STA:FW 172+23.47

EXISTING IRRIGATION

LINE CROSSING

STA: FW 174+39.81

EXISTING IRRIGATION

LINE CROSSING

STA: FW 174+49.81

8'' GATE VALVE

STA:FW 173+04.41

-190

-180

-170

-160

-150

-140

-130

-120

-190

-180

-170

-160

-150

-140

-130

-120

FW 170+00

-1 .2

-1

.7

-1 .2

-1

.4

-1 .1

-1

.2

-1 .8

-1

.0

-1 .5

-1

.8

FW 171+00

-1 .4

-1

.6

-1 .2

-1

.3

-1 .8

-1

.1

-1 .0

-1

.9

-1 .7

-1

.7

FW 172+00

-1 .4

-1

.5

-1 .3

-1

.2

-1 .5

-1

.3

-1 .6

-1

.6

-1 .7

-1

.8

FW 173+00

-1 .1

-1

.1

-1 .4

-1

.3

-1 .1

-1

.1

-1 .7

-1

.8

-1 .3

-1

.6

FW 174+00

-1 .7

-1

.4

-1 .5

-1

.2

-1 .1

-1

.0

-1 .6

-1

.8

-1 .6

-1

.6

FW 175+00

-1 .9

-1

.3

S T

A :F

W

.8

T

.O .P

E

L E

V

.3

G A

T E

V A

L V

E

S T

A

F W

.4

T .O

.P

E L

E V

.3

A

IR

R E

L E

A S

E V

A L

V E

S T

A

F W

.4

T .O

.P

E L

E V

.2

D E

G

B E

N D

S T

A :F

W

.3

T

.O .P

E

L E

V

.3

X

T

E E

S T

A :F

W

.9

T

.O .P

E

L E

V

.4

B L

O W

O F

F V

A L

V E

S T

A :F

W

.8

T

.O .P

E

L E

V

.3

D E

G

B E

N D

S T

A

F W

.8

T .O

.P

E L

E V

.9

E X

IS

T

IN

G

I R

R

IG

A T

IO

N

L

IN

E C

R O

S S

IN

G

S T

A

F W

.9

T .O

.P

E L

E V

.1

E X

IS

T

IN

G

U N

D E

R G

R O

U N

D T

E L

E P

H O

N E

L

IN

E C

R O

S S

IN

G

S T

A

F W

.8

T .O

.P

E L

E V

.9

E X

IS

T

IN

G

U N

D E

R G

R O

U N

D T

E L

E P

H O

N E

L

IN

E C

R O

S S

IN

G

S T

A

F W

.8

T .O

.P

E L

E V

.9

E X

IS

T

IN

G

I R

R

IG

A T

IO

N

L

IN

E C

R O

S S

IN

G

S T

A :F

W

.0

T

.O .P

E

L E

V

.7

G A

T E

V A

L V

E

S T

A :F

W

.4

T

.O .P

E

L E

V

.2

G A

T E

V A

L V

E

FO(D)

FO(D)

F W

501+00

F W

502+00

TIE INTO EXISTING VALVE

DATE:

DESIGNED:

TECH. REVIEW:

SUB SHEET NO.

PMIS/PKG NO.

DRAWING NO.

SHEET

OF

TITLE OF SHEET

FURNACE CREEK WATER

PLAN & PROFILE

SOUTH ALIGNMENT

178069

54 513

L. GRAEF

L. GRAEF

M. WHELEHON

1.17.2025

DEATH VALLEY

NATIONAL PARK

318717 01-

C1.29

HORIZ.

VERT.

PLAN

PROFILE 20 0 20 40

SCALE OF FEET

10 0 10 20

KEY MAP

NTS

APPROXIMATE EXISTING

GROUND SURFACE

EXISTING

UNDERGROUND

TELEPHONE LINE

SEE SHEET C1.67

EDGE OF

PAVEMENT

3.24' COVER

(MIN. COVER = 2.50')

DISTURBANCE

LIMIT 50'

EXISTING WATER MAIN

S E

E S

H E

E T

C 1.

S E

E S

H E

E T

C 1.

D C3.12

POTENTIAL DISTURBANCE

AREA. LOCATION FOR

40'X20'X6' HDD BORE PIT

SUNSET CAMPGROUND

ROAD

G R

E E

N

LA

N D

B

LV

D

DEATH VALLEY SCENIC

BYWAY, CA SR-190

8'' HDPE DR 11

WATER MAIN

8'' HDPE DR 11

WATER MAIN

A C3.12

A C3.15

D C3.15

PROTECT TREE IN PLACE

(TYP. ALL TREES WITHIN

DISTURBANCE LIMIT

UNLESS CALLED OUT ON

SHEET X1.0)

B C3.15

A C3.12

A C3.12

AutoCAD SHX Text 1/7/26 14:02 LAUREL.OTTEY F:\7194.05 DEVA WATER AND WASTEWATER SYSTEM REHAB\DRAWINGS\DWG\CIVIL\5 SHEET PRODUCTION\4_DEVA FC W_SOUTH

Kelly.Kero Cloud

Kelly.Kero Text Box

Kelly.Kero PolyLine

Sheets and Views
54 P&P - (7)

File details come from the government source that posted it. Updated .