B09_Amd10_-_QR55_Attach_Drawing_00-C8_27_Jan2026_0010.pdf
PDF 238 KB Posted
- Solicitation number
- 140P2025R0082
About this file
This is a technical drawing sheet for site fencing details related to a Water and Wastewater System Rehabilitation project at Death Valley National Park. The drawing, numbered C8.27 (Sheet 00 of 348-513), was designed by E. Anderson, technically reviewed by M. Whelehon, and dated January 17, 2025, with reference to PMIS/PKG No. 178069.
The drawing provides detailed specifications for three types of fencing installations: general chain link fence, swing gates, and pedestrian gates. The chain link fence specifications include 10-foot maximum post spacing with line posts spaced at typical intervals, 3/8-inch diameter truss rods, 7-gauge tension wire, 11-gauge wire fasteners, 9-gauge hog rings, and tension bands with stretcher bars. Posts are set in 12-inch diameter Class B concrete bases positioned 3 feet 6 inches below ground line. Line brace sections are required at 400-foot maximum intervals with 20-foot spans. The swing gate and pedestrian gate designs specify fork latches, hinges, drop rods, and similar structural components. General fence notes reference Specification Section 32 31 13 for additional fencing requirements including vinyl coating for environmental color matching, with the exception that proposed fencing at the wastewater treatment lagoons shall match existing fencing rather than environment color-matched vinyl.
View the file
Other files
Show 40 more
Latest 50 of 109 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
OF
TITLE OF SHEET
SITE FENCING
DETAILS
178069
348 513
E. ANDERSON
E. ANDERSON
M. WHELEHON
1.17.2025
DEATH VALLEY
NATIONAL PARK
318717 00-
C8.27
12"Ø CONCRETE BASE
1/2 3/2
6 1 3:4
5 L
AU
RE
L.O
TT
EY F
:\7
4.0 5 D
EV
A
W
AT
ER
A
ND
W
AS
TE
W
AT
ER
S
YS
TE
M
RE
HA
B\
DR
AW
IN
GS
\D W
G\
CI
VI
L\5
S
HE
ET
P
RO
DU
CT
IO
N\ 3_
DE
VA
F C
W _E
RO
SI
ON
C
ON
TR
OL
G
RA
DI
NG
.D
W G
NTS
A
C8.27
SITE FENCING AND GATE
FINISHED GRADE
HINGE (TYP.)
DROP ROD
LATCH
STRAIN POST
(TYP.)
TENSION BARS
STRETCHER BAR
AT EACH SIDE
VARIES
5' MAX
(TYP.)
6" MAX
1'
2.
5"
M
AX
20' LINE BRACE SECTION REQUIRED
AT 400' MAX INTERVALS
TOP RAIL (TYP.) LINE BRACE
POST & CENTER
POST (TYP.)
8" Ø TRUSS ROD
7 GA TENSION
WIRE
6" (T
YP
FINISHED GRADE
TENSION BAND &
STRETCHER BAR
LINE POST (TYP.)
2.
5"
M
AX
11 GA WIRE
FASTENERS
10' MAX POST SPACING
7 GA TENSION WIRE
8" Ø TRUSS ROD
FERRULE
END
POST
9 GA HOG
RINGS
BRACE RAIL
(TYP.)
TENSION BAND
12"Ø CLASS B CONCRETE
BASE - 3'-6" BELOW
GROUND LINE (TYP)
6'
3'
CHAIN LINK FENCE
SWING GATE PEDESTRIAN GATE
12"Ø CONCRETE BASE
FINISHED GRADE
HINGE (TYP.)
6" MAX
FORK LATCH
4'
6'
8" Ø TRUSS ROD
GENERAL FENCE NOTES:
1. SEE SPECIFICATION SECTION 32 31 13 FOR ADDITIONAL FENCING REQUIREMENTS INCLUDING VINYL
COATING FOR ENVIRONMENT COLOR MATCHING.
2. PROPOSED FENCING AT THE WASTEWATER TREATMENT LAGOONS IS TO MATCH EXISTING FENCING, AS
OPPOSED TO ENVIRONMENT COLOR MATCH VINYL.
| Sheets and Views |
| Fence Detail |
File details come from the government source that posted it. Updated .