B09_Amd8_-_Drawing_00-C3_18_Dec2025_0008.pdf

PDF 156 KB Posted

Attached to
DEVA 318717 - Rehab Furnace & Cow Creeks WTP/WWTP
Solicitation number
140P2025R0082
Issued by

About this file

This is a technical drawing specification sheet for water infrastructure details at Death Valley National Park, specifically the Water and Wastewater System Rehabilitation project. The drawing (Sheet C3.18, Drawing 178069) provides detailed specifications for valve and valve box tracer wire installations, duckbill check valve assemblies, and water meter valve configurations.

The valve and valve box tracer wire details specify a plan and section view configuration utilizing blue and red tracer wires with 1.5 LB 12 GA magnesium ground rods, PVC tape, three-way connectors, and two-terminal switchable access points for locating HDPE water main infrastructure. The duckbill check valve detail includes a ROMAC coupler on existing pipe with metal serrated gaskets, split backup retaining ring, and stainless steel 24-mesh screen, with notes requiring riprap restoration and ensuring drain outlets maintain 18 inches minimum above grade. The water meter valve detail specifies a configuration with 4-inch gate valves, Badger MAG meter, pressure gauges, sample taps, and ductile iron fittings meeting ANSI/AWWA standards C110/A21.10 and C115/A21.15, with interior coating meeting NSF-61 standards and exterior 2-part epoxy coating. The assembly includes a Shelterworks clamshell enclosure or approved equal with 3/4-inch crushed gravel drainage base one foot below the enclosure bottom.

View the file

Other files

File Type Posted
B09_Amd11_-_B08_Attach3_-_WD_CA20260020_Mod2_0011.pdf PDF
Sol_140P2025R0082_Amd_0011.pdf PDF
B09_Amd10_-_QR55_Attach_Drawing_01-C4_42_Jan2026_0010.pdf PDF
B09_Amd10_-_QR55_Attach_Drawing_01-C4_38_Jan2026_0010.pdf PDF
B09_Amd10_-_QR55_Attach_Drawing_01-C4_40_Jan2026_0010.pdf PDF
B09_Amd10_QR_Tracker_-_DEVA_318717_Final_0010.xlsx XLSX spreadsheet
B09_Amd10_-_QR55_Attach_Drawing_01-C4_39_Jan2026_0010.pdf PDF
B09_Amd10_-_QR55_Attach_Drawing_00-C8_27_Jan2026_0010.pdf PDF
B09_Amd10_-_QR86_Attach_Drawing_C1_40_0010.pdf PDF
B09_Amd10_-_Drawing_G1_22_0010.pdf PDF
B09_Amd10_-_QR86_Attach_Drawing_C1_40B_0010.pdf PDF
Sol_140P2025R0082_Amd_0010.pdf PDF
B09_Amd10_-_B08_Attach4_-_DetailedContractPriceSchedule_0010.xlsx XLSX spreadsheet
B09_Amd10_-_Drawing_G1_2_0010.pdf PDF
B09_Amd10_-_Drawing_Coversheet_00_DEVA_318717_Jan2026x_0010.pdf PDF
B09_Amd10_-_Drawing_G1_21_0010.pdf PDF
Sol_140P2025R0082_Amd_0009.pdf PDF
B09_Amd8_-_Drawing_02-C5_29_Jan2026_0008.pdf PDF
B09_Amd8_-_Spec_33_14_19_-_VALVES___HYDRANTS_FOR_WATER_UTILITY_SERVICE_0008.pdf PDF
B09_Amd8_-_Drawing_02-G1_16_Dec2025_0008.pdf PDF
B09_Amd8_-_Spec_08_33_22_-_ALUMINUM_ROLLING_OVERHEAD_DOORS_0008.pdf PDF
B09_Amd8_-_Drawing_01-C1_29_Jan2026_0008.pdf PDF
B09_Amd8_-_QR22_Attach_Drawing_00-C7_1_Jan2026_0008.pdf PDF
B09_Amd8_-_Drawing_02-C5_25_Jan2026_0008.pdf PDF
B09_Amd8_-_Drawing_00-C8_30_Dec2025_0008.pdf PDF
B09_Amd8_-_Drawing_01-C4_42_Jan2026_0008.pdf PDF
B09_Amd8_-_Drawing_01-C3_1_Dec2025_0008.pdf PDF
B09_Amd8_-_Drawing_00-C3_20_Dec2025_0008.pdf PDF
B09_Amd8_-_Spec_33_32_00_-_WASTEWATER_PUMPING_STATIONS_0008.pdf PDF
B09_Amd8_-_Spec_33_31_11_-_GRAVITY_SEWER_PIPELINE___MANHOLE_INSTALLATION_0008.pdf PDF
B09_Amd8_QR_Tracker_-_DEVA_318717_0008.xlsx XLSX spreadsheet
B09_Amd8_-_Drawing_Coversheet_00_DEVA_318717_Jan2026_0008.pdf PDF
Sol_140P2025R0082_Amd_0008.pdf PDF
B09_Amd8_-_Drawing_01-C1_31_Jan2026_0008.pdf PDF
B09_Amd8_-_Drawing_02-C6_7_Jan2026_0008.pdf PDF
B09_Amd8_-_Drawing_00-C3_15_Dec2025_0008.pdf PDF
B09_Amd8_-_Drawing_00-G1_2_Jan2026_0008.pdf PDF
B09_Amd8_-_Drawing_02-C7_5_Dec2025_0008.pdf PDF
B09_Amd8_-_Spec_33_11_13_-_POTABLE_WATER_SUPPLY_WELLS_0008.pdf PDF
B09_Amd8_-_Drawing_02-C5_33_Jan2026_0008.pdf PDF
B09_Amd8_-_Drawing_01-C1_42_Jan2026_0008.pdf PDF
B09_Amd8_-_QR56_Attach_Drawing_02-C2_20_Dec2025_0008.pdf PDF
B09_Amd8_-_Spec_33_31_05_-_MANHOLE_LINING___REHABILITATION_0008.pdf PDF
B09_Amd8_-_Drawing_01-G1_15_Jan2026_0008.pdf PDF
B09_Amd8_-_QR56_Attach_Drawing_02-C2_18_Dec2025_0008.pdf PDF
B09_Amd8_-_Drawing_01-C1_67_Jan2026_0008.pdf PDF
B09_Amd8_-_Spec_46_33_11_-_CHEMICAL_FEED_-_LIQUID_SYSTEMS_0008.pdf PDF
B09_Amd8_-_Drawing_02-C2_22_Jan2026_0008.pdf PDF
B09_Amd8_-_Drawing_02-X1_2_Jan2026_0008.pdf PDF
B09_Amd8_-_QR22_Attach_Drawing_02-C5_64_Jan2026_0008.pdf PDF
Show 40 more

Latest 50 of 109 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

8-12"

/17 /25

:38

K

EL

LY

.K

ER

O F

:\7

4.0 5 D

EV

A

W

AT

ER

A

ND

W

AS

TE

W

AT

ER

S

YS

TE

M

RE

HA

B\

DR

AW

IN

GS

\D W

G\

CI

VI

L\5

S

HE

ET

P

RO

DU

CT

IO

N\ 5_

DE

VA

W _W

W D

ET

AI

LS

W

.D W

G

DATE:

DESIGNED:

TECH. REVIEW:

SUB SHEET NO.

PMIS/PKG NO.

DRAWING NO.

SHEET

OF

TITLE OF SHEET

WATER DETAILS 143

178069

172 513

DJ&A

DJ&A

M. WHELEHON

1.17.2025

DEATH VALLEY

NATIONAL PARK

318717 00-

C3.18

NTS

C3.18

VALVE & VALVE BOX TRACER WIRE PLAN VIEW

FINISHED

GRADE

TWO-TERMINAL

SWITCHABLE

ACCESS

POINT

COIL UP TO 3' OF

EXTRA BLUE WIRE IN

ACCESS POINT

TRACER WIRE, BLUE

GROUND ROD

TRACER WIRE,

RED

1.5 LB 12 GA MAGNESIUM

GROUND ROD

VALVE

BOX

PVC

TAPE

THREE-WAY

CONNECTOR

HDPE WATER

MAIN

1.5 LB 12 GA MAGNESIUM

GROUND ROD

PVC

TAPE

TWO-TERMINAL SWITCHABLE

ACCESS POINT

GROUND ROD

TRACER WIRE,

RED

TRACER

WIRE,

BLUE

NOTES:

TBD

VALVE

BOX

LID

NTS

C3.18

VALVE & VALVE BOX TRACER WIRE PLAN VIEW

NTS

C3.18

VALVE & VALVE BOX TRACER WIRE SECTION VIEW

ROMAC

COUPLER ON

EXISTING PIPE GASKET

METAL SERRATED

GASKET

SPLIT BACKUP

RETAINING RING

DUCKBILL CHECK VALVE

STAINLESS STEEL

24-MESH SCREEN

CHECK VALVE NOTES:

1. RESTORE RIPRAP AT OUTLET LOCATION AS NEEDED

2. ENSURE DRAIN OUTLETS ARE 18" MINIMUM ABOVE GRADE.

NTS

A

C3.18

DUCKBILL CHECK VALVE DETAIL

23' - 78"

2'

1"

WATER METER NOTES:

1. FITTINGS ARE DUCTILE IRON IN ACCORDANCE WIT

HANSI/AWWA C110/A21.10. FLANGES ARE ANSI CLASS 125,

B16.1.

2. 3" PIPE AND LARGER ARE DUCTILE IRON IN ACCORDANCE

WITH ANSI/AWWA C115/A21.15. FLANGES ARE ANSI CLASS

125, B16.1.

3. DUCTILE IRON PIPE & FITTINGS INTERIOR COATING MEETS

THE REQUIREMENT OF NSF-61 STANDARD. EXTERIOR

COATING TO BE A 2-PART EPOXY.

SAMPLE TAP

4'' GATE VALVE

PRESSURE GAUGE 4'' BADGER MAG METER

4'' GATE VALVE

PIPE SUPPORTS

TYP.

SHELTERWORKS CLAMSHELL

ASSEMBLY OR APPROVED

EQUAL

4'' GATE VALVE

4'' GATE VALVE

4'' CRUSHED GRAVEL

1-FOOT BELOW BOTTOM

OF ENCLOSURE TO

ALLOW FOR DRAINAGE

PRESSURE GAUGE 4'' BADGER MAG METER

4'' DI BLIND

FLANGE ON

TEE

SAMPLE TAP

SHELTERWORKS

CLAMSHELL ASSEMBLY

OR APPROVED EQUAL

NTS

B

C3.18

WATER METER VALVE DETAIL1

Sheets and Views
Water Details 7

File details come from the government source that posted it. Updated .