G11_-_TEMPORARY_PROTECTION_-_INTERIOR_-_EXHIBIT_LEVEL_0009.pdf
PDF 880 KB Posted
- Attached to
- NAMA 216042 - Lincoln Memorial Rehabilitation
- Solicitation number
- 140P2022R0046
About this file
This document provides plans and specifications for temporary interior protection during rehabilitation work at the Lincoln Memorial in Washington, D.C. The project involves providing protective measures to historic fabric and surfaces throughout construction, including temporary vertical access, barriers around work areas, and covering or shielding exposed walls, columns, stairways and other features. Contractors must coordinate daily access and limits of work with the owner and Park Police to minimize disturbance. All protective materials must be non-staining and non-friable as specified. Related solicitation number 140P2022R0046 from the Department of the Interior National Park Service concerns the NAMA 216042 Lincoln Memorial Undercroft rehabilitation project and seeks contractors to implement the temporary interior protection plans depicted and ensure public access is maintained throughout.
View the file
Other files
Show 40 more
Latest 50 of 171 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 3 4 6 7 8 9 10 12 13 14 15 16 17 18
B
C
D
G
H
L
M
E
F
J
K
N
O
P
A
02.72
02.75
02.76 02.76
02.75
:TYP.
02.112
:TYP.
02.112
EXISTING BEAMS BELOW
STAIRS (TYP)
B1
1. PUBLIC ACCESS TO THE MEMORIAL VIA THE MAIN STAIR (MIN.
40'-0" WIDE) AND THE TEMPORARY VERTICAL ACCESS MUST
BE PROVIDED THROUGHOUT THE DURATION OF THE WORK.
CONTRACTOR IS RESPONSIBLE FOR MAINTENANCE OF THE
TEMPORARY LIFT.
2. CONCEPTUAL INITIAL LIMIT OF WORK AREA IS SHOWN.
CONTRACTOR TO MEET WITH THE OWNER AND US PARK
POLICE TO DEFINE AND ADJUST THE LIMITS OF
CONSTRUCTION ACCESS TO THE TERRACE AND MAIN STAIR
AT VARIOUS STAGES OF THE WORK.
3. NO EQUIPMENT, MATERIALS OR OTHER CONSTRUCTION
RELATED ITEMS SHALL BE PLACED OR LEANED AGAINST THE
EXISTING WALLS AND COLUMNS.
4. DAILY CONSTRUCTION ACCESS SHALL BE LIMITED TO THE
PATHWAYS SHOWN TO LIMIT THE AMOUNT OF DISTURBANCE
TO THE EXISTING TERRAIN.
5. TEMPORARY PROTECTION MUST BE PROVIDED AT ALL POINTS
OF CONTACT WITH HISTORIC FABRIC. CONTRACTOR TO USE
NON-STAINING AND NON-FRIABLE MATERIALS FOR
TEMPORARY PROTECTION. SEE SPECIFICATIONS.
OWNER PROVIDED AND INSTALLED
PROTECTION OF HISTORIC GRAFFITI (NIC)
EXTENT OF PROTECTION FOR EXISTING
RAISED TERRACE WALLS AND STYLOBATE.
CONSTRUCTION AREA PATHWAY. AREA TO BE
COVERED WITH GRAVEL & GEO-TEXTILE FABRIC
AREA OF RAISED TERRACE CONSTRUCTION ACCESS
WALL / COLUMN PROTECTION TO A HEIGHT
OF 8'-0" ABOVE GRADE LEVEL
WALL / COLUMN PROTECTION FULL HEIGHT
ABOVE GRADE LEVEL
LEGEND
CHAINLINK FENCE
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF
GENERAL NOTES
132917
NAMA-216042
SEAL
KEY NOTES
B
IM
L in c o ln
M e m o ri a l U n d e rc ro ft L in c o ln
M e m o ri a l_ A rc h U n d e rc ro ft .r v t
QE
QE
G11
TEMPORARY
PROTECTION - INTERIOR -
EXHIBIT LEVEL
LINCOLN MEMORIAL REHABILITATION
NATIONAL MALL AND MEMORIAL PARKS
QE
5/13/2022 14
SCALE AG11
1 EXHIBIT - INTERIOR PROTECTION PLAN
02.72 EXISTING GRANITE COPING AND WALL. PROVIDE
PROTECTION THROUGH OUT CONSTRUCTION. SEE G
SHEETS
02.75 EXISTING GRANITE STAIR WALL. PROVIDE PROTECTION.
02.76 PROTECTION OF ADJACENT EXISTING GRANITE WALL MUST
REMAIN IN PLACE DURING ENLARGEMENT OF EXISTING
DOOR OPENINGS.
02.112 WALL AND COLUMN PROTECTION. EXTEND FULL HEIGHT
ABOVE GRADE. SEE SPECIFICATIONS.
SCALE OF FEET
16 32160
SCALE A
NO. REVISION DATE BY
B1 BID ADDENDUM 3 7/1/2022
SEAL
| Sheets |
| A30 - UTILITY LEVEL RCP |
| A31 - EXHIBIT LEVEL RCP |
| A51 - NORTH & SOUTH ELEVATIONS |
| A82 - INTERIOR ELEVATIONS - ELEVATORS |
| A99 - CHAMBER LEVEL - ENLARGED PLANS |
| A100 - EXHIBIT LEVEL - ENLARGED RCP - ENTRY VESTIBULES |
| A101 - EXHIBIT LEVEL - ENLARGED RCP - SCREENING |
| A102 - EXHIBIT LEVEL - ENLARGED RCP - NORTH EXHIBIT |
| A103 - EXHIBIT LEVEL - ENLARGED RCP - CENTRAL EXHIBIT |
| A104 - EXHIBIT LEVEL - ENLARGED RCP - SOUTH EXHIBIT |
| A105 - EXHIBIT LEVEL - ENLARGED RCP - RETAIL |
| A106 - EXHIBIT LEVEL - ENLARGED RCP - NORTH EXIT AND BREAK ROOM |
| A107 - EXHIBIT LEVEL - ENLARGED RCP - TOILET |
| A108 - EXHIBIT LEVEL - ENLARGED RCP - UNISTRUT FRAME |
| A127 - INTERIOR ELEVATIONS - WOMEN'S & MEN'S TOILETS |
| A128 - INTERIOR ELEVATIONS - FAMILY & UNISEX TOILETS |
| A153 - MATERIAL SCHEDULE |
| A154 - FINISH SCHEDULE |
| G10 - TEMPORARY PROTECTION - INTERIOR - UTILITY LEVEL |
| G11 - TEMPORARY PROTECTION - INTERIOR - EXHIBIT LEVEL |
File details come from the government source that posted it. Updated .