A104_-_EXHIBIT_LEVEL_-_ENLARGED_RCP_-_SOUTH_EXHIBIT_0009.pdf
PDF 977 KB Posted
- Attached to
- NAMA 216042 - Lincoln Memorial Rehabilitation
- Solicitation number
- 140P2022R0046
About this file
This document includes construction drawings and specifications for the Lincoln Memorial Rehabilitation project. The drawings depict reflected ceiling plans, details, elevations, schedules, and notes for renovations to the exhibit level ceilings, lighting, acoustical treatments, security equipment, and toilet areas within the Lincoln Memorial Undercroft. Relevant construction materials, finishes, and equipment are specified. Temporary protection plans are also included for interior work on the utility and exhibit levels.
The related federal contract opportunity is a solicitation for the NAMA 216042 Lincoln Memorial Rehabilitation project being conducted by the National Park Service National Office. The project involves rehabilitation of the Lincoln Memorial Undercroft area. The response due date and award date are not provided in the available information.
View the file
Other files
Show 40 more
Latest 50 of 171 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C
PA FS
E X
C
6 7
J
K
ELEVATOR
ELV1
SOUTH
EXHIBIT
21' - 10 7/8" AFF 21' - 8 3/4" AFF
22' - 7" AFF
EXPOSED
09.05
26.01
26.01
E Q
E Q
EQ EQ
/2
16'-4 1/4" ± 16'-4 3/4" ±
A104
28.06
28.04
27.01
E Q
E Q
02.99
02.99
4'-1 1/2" 8" 9'-1 1/2" 8" 9'-1 1/2" 8" 9'-1 1/2" 8" 9'-1 1/2"
A104
A104
02.99
02.99
02.99
02.9902.99
A104
B1
1. REFER TO A153 AND A154 FOR MATERIALS AND FINISHES
SCHEDULES
AP-2
ACOUSTIC
PLASTER
GWB- 1
GYPSUM BOARD
ACP-1
ACOUSTICAL
CEILING
PANEL
AP-1
ACOUSTIC
PLASTER
AP-3
ACOUSTIC
PLASTER
E Q
U A
L
E Q
U A
L
R E
F E
R T
O C
E
IL
IN
G
P L
A N
PANEL MOUNTED DEVICE
REFER TO MEP DRAWINGS
AND SECURITY FOR DEVICES
PENDANT MOUNTED LIGHT
FIXTURE - CENTER IN OPENING
WOOD DOWELED CEILING
GRILLE - 2 MEMBER PER LINEAR
FOOT
SLOT DIFFUSER - REFER TO
MECHANICAL AND CEILING
PLANS
CROSSPIECE BACKER BY
CEILING GRILLE
MANUFACTURER
CLR
8" 1'-0"
A105
HATCH OF UNISTRUCT FRAME
ABOVE - REFER TO A108
E Q
U A
L
C
L R
E Q
U A
L
R E
F E
R T
O C
E
IL
IN
G
P L A
N
PANEL MOUNTED DEVICE
REFER TO MEP
DRAWINGS AND SECURITY
FOR DEVICES
PENDANT MOUNTED LIGHT
FIXURE - CENTER IN OPENING
WOOD DOWELED CEILING
GRILLE - 2 MEMBERS PER
LINEAR FOOT
CROSSPIECE BACKER
CEILING GRILLE
MANUFACTURER
HATCH OF UNISTRUCT FRAME
ABOVE - REFER TO A108
CLR
8" 1'-0"
16 GA. STEEL PANEL (PTD)
WITH COUNTER SUNK
SCREWS TO DRYWALL
GRID SYSTEM
A105
SOUTH
EXHIBIT
SERVICES
CORRIDOR
CONC COLUMN,
EXIST. TO REMAIN
EXISTING CONCRETE ARCH
3-5/8" METAL STUD TO UNDERSIDE
OF SLAB ABOVE - BRACE AT 32" OC
WOOD SLAT CEILING GILLE ON
SUSPENDED CEILING GRID
CEILING MOUNTED SIGNAGE (NIC)
ACOUSTIC PLASTER
CEILING
3/4" PLYWOOD STOP AT TOP OF
CONCRETE ARCH
TONGUE & GROOVE WOOD
PANELING (WD-1) STOP AT TOP
OF CONCRETE ARCH
UNISTRUCT FRAME
SECURED TO CONCRETE
ABOVE WITH 2" ACOUSTICAL
PANELS - REFER TO A108
48' - 10 7/8"
/2
/2
CONCRETE SLAB,
EXISTING TO REMAIN
ACOUSTICAL BOARD
ADHESIVE
1" THICK ACOUSTIC
PLASTER CEILING
BOARD
1/8" ACOUSTIC
CEILING PLASTER
EXISTING ARCH TO
REMAIN
PRESSURE TREATED
WOOD BLOCKING
6" MTL STUD
1/2" GWB
C CHANNEL
DOWN LIGHT FIXTURE
CEILING MOUNTED EXIT SIGN
FIRE ALARM SPEAKER STROBE
FIXED DOME CAMERA
FIXED MULTI IMAGER
EX
FS
C
C
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF
LEGEND
GENERAL NOTES
KEY NOTES
132917
NAMA-216042
SEAL
B
IM
L in c o ln
M e m o ri a l U n d e rc ro ft L in c o ln
M e m o ri a l_ A rc h U n d e rc ro ft .r v t
QE
QE
A104
EXHIBIT LEVEL -
ENLARGED RCP - SOUTH
EXHIBIT
LINCOLN MEMORIAL REHABILITATION
NATIONAL MALL AND MEMORIAL PARKS
QE
5/13/2022 152
SCALE OF FEET
4 840
SCALE A
02.24 CONCRETE SLAB, EXISTING TO REMAIN
02.79 CONC COLUMN, EXIST. TO REMAIN
02.99 EXISTING ARCH TO REMAIN
06.11 PRESSURE TREATED WOOD BLOCKING
09.03 1/2" GWB
09.05 SUSPENDED ACOUSTIC WOOD SLAT CEILING
09.11 6" MTL STUD
09.22 ACOUSTICAL BOARD ADHESIVE
09.23 1" THICK ACOUSTIC PLASTER CEILING BOARD
09.24 1/8" ACOUSTIC CEILING PLASTER
09.25 C CHANNEL
26.01 LIGHT FIXTURE. SEE ELECTRICAL DWGS.
27.01 PUBLIC ADDRESS SPEAKER. SEE SECURITY DWGS.
28.04 FIRE ALARM SPEAKER/STROBE. SEE FIRE DETECTION
DWGS.
28.06 CAMERA. SEE SECURITY DWGS.
99.02 ACOUSTIC PLASTER CEILING
SCALE AA104A42
1 EXHIBIT LEVEL - ENLARGED REFLECTED CEILING PLAN - SOUTH EXHIBIT
SCALE OF FEET
1 30 1 2
SCALE B
SCALE BA104A103
4 CEILING PLAN DETAIL
SCALE BA104A104
3 CEILING PLAN DETAIL
SCALE CA104A104
2 WOOD SLAT CEILING - TRANSITION DTL
SCALE CA104A104
5 ACOUSTIC PLASTER (AP-2) DETAIL - TYP
SCALE OF FEET
12 126 0
SCALE C
NO. REVISION DATE BY
B1 BID ADDENDUM 3 7/1/2022
SEAL
| Sheets |
| A30 - UTILITY LEVEL RCP |
| A31 - EXHIBIT LEVEL RCP |
| A51 - NORTH & SOUTH ELEVATIONS |
| A82 - INTERIOR ELEVATIONS - ELEVATORS |
| A99 - CHAMBER LEVEL - ENLARGED PLANS |
| A100 - EXHIBIT LEVEL - ENLARGED RCP - ENTRY VESTIBULES |
| A101 - EXHIBIT LEVEL - ENLARGED RCP - SCREENING |
| A102 - EXHIBIT LEVEL - ENLARGED RCP - NORTH EXHIBIT |
| A103 - EXHIBIT LEVEL - ENLARGED RCP - CENTRAL EXHIBIT |
| A104 - EXHIBIT LEVEL - ENLARGED RCP - SOUTH EXHIBIT |
| A105 - EXHIBIT LEVEL - ENLARGED RCP - RETAIL |
| A106 - EXHIBIT LEVEL - ENLARGED RCP - NORTH EXIT AND BREAK ROOM |
| A107 - EXHIBIT LEVEL - ENLARGED RCP - TOILET |
| A108 - EXHIBIT LEVEL - ENLARGED RCP - UNISTRUT FRAME |
| A127 - INTERIOR ELEVATIONS - WOMEN'S & MEN'S TOILETS |
| A128 - INTERIOR ELEVATIONS - FAMILY & UNISEX TOILETS |
| A153 - MATERIAL SCHEDULE |
| A154 - FINISH SCHEDULE |
| G10 - TEMPORARY PROTECTION - INTERIOR - UTILITY LEVEL |
| G11 - TEMPORARY PROTECTION - INTERIOR - EXHIBIT LEVEL |