A154_-_FINISH_SCHEDULE_0009.pdf
PDF 795 KB Posted
- Attached to
- NAMA 216042 - Lincoln Memorial Rehabilitation
- Solicitation number
- 140P2022R0046
About this file
This document is a finish schedule for the Lincoln Memorial Rehabilitation project. It provides specifications for flooring, wall, door, and ceiling finishes for various rooms in the utility level, exhibit level, and chamber level. Key areas include the south and north mechanical rooms, elevator machine rooms, electrical rooms, toilet facilities, exhibit and retail spaces, offices, corridors, stairwells, and the statuary chamber. Finish materials include concrete, terrazzo, polished concrete, wallcoverings, painted gypsum board, and acoustic wall panels. The schedule also references related architectural drawings covering floor plans, reflected ceiling plans, elevations, and details.
The associated federal contract opportunity is a solicitation for the NAMA 216042 Lincoln Memorial Rehabilitation project issued by the National Park Service National Office. The opportunity involves rehabilitation work at the Lincoln Memorial Undercroft. The solicitation number is 140P2022R0046.
View the file
Other files
Show 40 more
Latest 50 of 171 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF
132917
NAMA-216042
SEAL
B
IM
L in c o ln
M e m o ri a l U n d e rc ro ft L in c o ln
M e m o ri a l_ A rc h U n d e rc ro ft .r v t
QE
QE
A154
FINISH SCHEDULE
LINCOLN MEMORIAL REHABILITATION
NATIONAL MALL AND MEMORIAL PARKS
QE
5/13/2022 187
FINISH SCHEDULE
ROOM NUMBER ROOM NAME
FLOOR
BASE
WALLS DOOR
CEILING COMMENTSFIELD NORTH EAST SOUTH WEST DOOR FRAME
UTILITY LEVEL
001 SOUTH MECHANICAL CONC-2 NONE PT-3 PT-3 PT-3 PT-3 PT-1
003 SOUTH ELEVATOR MACHINE ROOM CONC-2 NONE PT-3 PT-3 PT-3 PT-3 PT-1
005 SOUTH ELEVATOR VESTIBULE CONC-2 NONE PT-3 PT-3 PT-3 PT-3 PT-1
006 MAIN ELECTRICAL CONC-2 NONE PT-3 PT-3 PT-3 PT-3 PT-1
006A LIGHTING INVERTER CONC-2 NONE PT-3 PT-3 PT-3 PT-3 PT-1
007 FIRE PUMP CONC-2 NONE PT-3 PT-3 PT-3 PT-3 PT-1
008 NORTH ELEVATOR VESTIBULE CONC-2 NONE PT-3 PT-3 PT-3 PT-3 PT-1
009 NORTH ELEVATOR MACHINE ROOM CONC-2 NONE PT-3 PT-3 PT-3 PT-3 PT-1
011 NORTH MECHANICAL CONC-2 NONE PT-3 PT-3 PT-3 PT-3 PT-1
013 NPS STORAGE RFT-1 RB-1 PT-3 PT-3 PT-3 PT-3 PT-1
015 NPS / RETAIL IT RFT-1 RB-1 PT-3 PT-3 PT-3 PT-3 PT-1
017 EXHIBIT IT / AV RFT-1 RB-1 PT-3 PT-3 PT-3 PT-3 PT-1
019 IT ROOM RFT-1 RB-1 PT-3 PT-3 PT-3 PT-3 PT-1
020 TELECOM CONC-2 NONE PT-3 PT-3 PT-3 PT-3 PT-1
ST1.0 STAIR 1 CONC-2 NONE PT-3 PT-3 PT-3 PT-3 PT-1
STAIR LANDING 1
301 STORAGE
MEZZANINE
154 BOH ACCESS EXIST / CONC-2 NONE EXIST EXIST PT-5 EXIST EXIST
EXHIBIT LEVEL
100 SOUTH VESTIBULE PCT-1 SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV SEE INT. ELEV. AP-1
101 FIRE CONTROL ROOM CONC-2 NONE PT-3 PT-3 PT-3 PT-3 PT-1
102 SOUTH ELEVATOR LOBBY PCT-1 SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV SEE INT. ELEV. AP-1
104 SOUTH SALLY PORT EXIT PCT-1 SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV SEE INT. ELEV. AP-1
110 SERVICES CORRIDOR PCT-1 SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV SEE INT. ELEV. AP-3
110A VESTIBULE PCT-1 SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV SEE INT. ELEV. AP-1
111 WOMEN'S VESTIBULE CT-1 CT-5 CT-2 CT-2 CT-2 CT-2 PT-1
112 WOMEN'S TOILETS CT-1 SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV SEE INT. ELEV. PT-1
113 JANITOR CT-1 CT-5 CT-2 CT-2 CT-2 CT-2 PT-1
114 MEN'S VESTIBULE CT-1 CT-5 CT-2 CT-2 CT-2 CT-2 PT-1
115 MEN'S RESTROOM CT-1 SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV SEE INT. ELEV. PT-1
116 JANITOR CT-1 CT-5 CT-2 CT-2 CT-2 CT-2 PT-1
117 UNISEX TOILET CT-1 SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV SEE INT. ELEV. PT-1
118 FAMILY TOILET CT-1 CT-5 CT-2 CT-2 CT-2 CT-2 PT-1
119 FAMILY TOILET CT-1 CT-5 CT-2 CT-2 CT-2 CT-2 PT-1
120 EXHIBIT SPINE PCT-1 SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV SEE INT. ELEV. WSC-1
121 NORTH EXHIBIT PCT-1 SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV SEE INT. ELEV. WSC-1
122 IMMERSIVE FORUM PCT-1 SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV SEE INT. ELEV. AP-2 , WSC-1
123 SOUTH EXHIBIT PCT-1 SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV SEE INT. ELEV. WSC-1
130 RETAIL PCT-1 SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV SEE INT. ELEV. AP-2
131 RETAIL STORAGE RFT-1 RB-1 PT-3 PT-3 PT-3 PT-3 ACP -1
132 RETAIL OFFICE RFT-1 RB-1 PT-3 PT-3 PT-3 PT-3 ACP -1
140 NORTH VESTIBULE PCT-1 SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV SEE INT. ELEV. AP-1
141 PRE-SCREENING PCT-1 SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV SEE INT. ELEV. AP-1
142 POST SCREENING PCT-1 SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV SEE INT. ELEV. AP-1
143 EXHIBIT SALLY PORT PCT-1 SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV SEE INT. ELEV. AP-1
144 WORK ROOM RFT-1 RB-1 PT-3 PT-3 PT-3 PT-3 ACP -1 PROVIDE BASE ON NEW WALLS ONLY. DO NOT ADD BASE TO EXISTING CONCRETE COLUMNS.
144A STORAGE RFT-1 RB-1 PT-3 PT-3 PT-3 PT-3 ACP -1 PROVIDE BASE ON NEW WALLS ONLY. DO NOT ADD BASE TO EXISTING CONCRETE COLUMNS.
145 NORTH ELEVATOR LOBBY PCT-1 SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV SEE INT. ELEV. AP-1
146 NORTH SALLY PORT EXIT PCT-1 SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV. SEE INT. ELEV SEE INT. ELEV. AP-1
151 OFFICE RFT-1 RB-1 PT-3 PT-3 PT-3 PT-3 ACP-2
153 CORR RT-1 RB-1 PT-3 PT-3 PT-3 PT-3 GWB-1 PROVIDE BASE ON NEW WALLS ONLY. DO NOT ADD BASE TO EXISTING CONCRETE COLUMNS.
ST1.1 STAIR 1 CONC-2 NONE PT-3 PT-3 PT-3 PT-3 PT-1
CHAMBER
200 STATUARY CHAMBER NIC NIC NIC NIC NIC NIC NIC
201 NPS WORKROOM EXIST STONE EXIST STONE PT-4 PT-4 PT-4 PT-4 PT-5
201A TOILET EXIST STONE EXIST STONE PT-4 PT-4 PT-4 PT-4 PT-5
201B STORAGE
203 USPP EXIST VCT EXIST
PAINTED
PT-4 PT-4 PT-4 PT-4 PT-5
203A TOILET EXIST STONE EXIST STONE PT-4 PT-4 PT-4 PT-4 PT-5
204 NORTH ELEVATOR VESTIBULE ST-1 ST-1 PT-4 PT-4 PT-4 PT-4 PT-5
205 GREEN ROOM ST-1 ST-1 PT-4 PT-4 PT-4 PT-4 PT-5
206 JANITOR'S CLOSET CT-3 CT-3 CT-4 CT-4 CT-4 CT-4 PT-1
207 SOUTH ELEVATOR VESTIBULE EXIST STONE EXIST STONE PT-4 PT-4 PT-4 PT-4 PT-5
B1
B1
B1
B1
B1
B2
NO. REVISION DATE BY
B1 BID ADDENDUM 2 6/24/2022 QE
B2 BID ADDENDUM 3 7/1/2022
B2
B2B2
B2
B2
B2
B2
SEAL
| Sheets |
| A30 - UTILITY LEVEL RCP |
| A31 - EXHIBIT LEVEL RCP |
| A51 - NORTH & SOUTH ELEVATIONS |
| A82 - INTERIOR ELEVATIONS - ELEVATORS |
| A99 - CHAMBER LEVEL - ENLARGED PLANS |
| A100 - EXHIBIT LEVEL - ENLARGED RCP - ENTRY VESTIBULES |
| A101 - EXHIBIT LEVEL - ENLARGED RCP - SCREENING |
| A102 - EXHIBIT LEVEL - ENLARGED RCP - NORTH EXHIBIT |
| A103 - EXHIBIT LEVEL - ENLARGED RCP - CENTRAL EXHIBIT |
| A104 - EXHIBIT LEVEL - ENLARGED RCP - SOUTH EXHIBIT |
| A105 - EXHIBIT LEVEL - ENLARGED RCP - RETAIL |
| A106 - EXHIBIT LEVEL - ENLARGED RCP - NORTH EXIT AND BREAK ROOM |
| A107 - EXHIBIT LEVEL - ENLARGED RCP - TOILET |
| A108 - EXHIBIT LEVEL - ENLARGED RCP - UNISTRUT FRAME |
| A127 - INTERIOR ELEVATIONS - WOMEN'S & MEN'S TOILETS |
| A128 - INTERIOR ELEVATIONS - FAMILY & UNISEX TOILETS |
| A153 - MATERIAL SCHEDULE |
| A154 - FINISH SCHEDULE |
| G10 - TEMPORARY PROTECTION - INTERIOR - UTILITY LEVEL |
| G11 - TEMPORARY PROTECTION - INTERIOR - EXHIBIT LEVEL |
File details come from the government source that posted it. Updated .