G10_-_TEMPORARY_PROTECTION_-_INTERIOR_-_UTILITY_LEVEL_0009.pdf
PDF 874 KB Posted
- Attached to
- NAMA 216042 - Lincoln Memorial Rehabilitation
- Solicitation number
- 140P2022R0046
About this file
This document provides plans for temporary interior protection at the Lincoln Memorial during a rehabilitation project. The project involves installing temporary protection at access points, along primary construction pathways, and around historic walls, columns, and other structures to prevent damage during work. Protection such as chain link fencing, gravel bases, vapor barriers, and panels extending to full height will be put in place. The contractor must coordinate daily access routes and work areas with the owner and ensure public access to the memorial is maintained throughout. Special precautions are also noted for culturally protected areas and locations containing historic graffiti.
View the file
Other files
Show 40 more
Latest 50 of 171 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 3 4 6 7 8 9 10 12 13 14 15 16 17 18
B
C
D
G
H
L
M
E
F
J
K
N
O
P
A
02.5202.5202.5202.5202.52 02.5202.5202.52
02.5202.5202.52 02.5202.52
02.52
02.53
02.53
CONSTRUCTION ACCESS SHAFT
WITH PRE-CAST ROOF. OPTION
TO DEMOLISH VAULT AND
CONSTUCT RAMP. COORDINATE
WITH OWNER.
EXISTING OPENING
TO THE CHAMBER
UNDERCROFT
V
IF
VIF
11'-11" ±
EXISTING OVERHEAD COILING DOOR TO
APPROACHWAY UNDERCROFT. NO ACCESS
ALLOWED UNLESS PRE-APPROVED BY USPP OR
NAMA. THE DOOR REMAINS OPEN TO PROVIDE
CIRCULATION OF AREA INTO THE
APPROACHWAY UNDERCROFT. PROVIDE
CHAINLINK FENCING WITH MAN DOOR IN FRONT
OF OPENING TO SECURE AREA.
APPROACHWAY
UNDERCROFT
MAIN STAIR
UNDERCROFT
CHAMBER
UNDERCROFT
RAISED
TERRACE
UNDERCROFT
02.17
02.17
02.17
02.17
02.17
EDGE OF
EXISTING
MEZZANINE
ABOVE
:TYP.
02.111
:TYP.
02.112
02.153
02.153
02.153
RAISED TERRACE
UNDERCROFT
RAISED
TERRACE
UNDERCROFT
02.53
02.53
02.152
02.52
02.52 02.52
02.52
02.52
02.52
B1
B1
8' - 0"
8' - 0"
1. PUBLIC ACCESS TO THE MEMORIAL VIA THE MAIN STAIR (MIN.
40'-0" WIDE) AND THE TEMPORARY VERTICAL ACCESS MUST
BE PROVIDED THROUGHOUT THE DURATION OF THE WORK.
CONTRACTOR IS RESPONSIBLE FOR MAINTENANCE OF THE
TEMPORARY LIFT.
2. CONCEPTUAL INITIAL LIMIT OF WORK AREA IS SHOWN.
CONTRACTOR TO MEET WITH THE OWNER AND US PARK
POLICE TO DEFINE AND ADJUST THE LIMITS OF
CONSTRUCTION ACCESS TO THE TERRACE AND MAIN STAIR
AT VARIOUS STAGES OF THE WORK.
3. NO EQUIPMENT, MATERIALS OR OTHER CONSTRUCTION
RELATED ITEMS SHALL BE PLACED OR LEANED AGAINST THE
EXISTING WALLS AND COLUMNS.
4. DAILY CONSTRUCTION ACCESS SHALL BE LIMITED TO THE
PATHWAYS SHOWN TO LIMIT THE AMOUNT OF DISTURBANCE
TO THE EXISTING TERRAIN.
5. TEMPORARY PROTECTION MUST BE PROVIDED AT ALL POINTS
OF CONTACT WITH HISTORIC FABRIC. CONTRACTOR TO USE
NON-STAINING AND NON-FRIABLE MATERIALS FOR
TEMPORARY PROTECTION. SEE SPECIFICATIONS.
OWNER PROVIDED AND INSTALLED
PROTECTION OF HISTORIC GRAFFITI (NIC)
EXTENT OF PROTECTION FOR EXISTING
RAISED TERRACE WALLS AND STYLOBATE.
CONSTRUCTION AREA PATHWAY. AREA TO BE
COVERED WITH GRAVEL & GEO-TEXTILE FABRIC
AREA OF RAISED TERRACE CONSTRUCTION ACCESS
WALL / COLUMN PROTECTION TO A HEIGHT
OF 8'-0" ABOVE GRADE LEVEL
WALL / COLUMN PROTECTION FULL HEIGHT
ABOVE GRADE LEVEL
LEGEND
CHAINLINK FENCE
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF
GENERAL NOTES
132917
NAMA-216042
SEAL
KEY NOTES
B
IM
L in c o ln
M e m o ri a l U n d e rc ro ft L in c o ln
M e m o ri a l_ A rc h U n d e rc ro ft .r v t
QE
QE
G10
TEMPORARY
PROTECTION - INTERIOR -
UTILITY LEVEL
LINCOLN MEMORIAL REHABILITATION
NATIONAL MALL AND MEMORIAL PARKS
QE
5/13/2022 13
SCALE AG10
1 UTILITY LEVEL - INTERIOR PROTECTION PLAN
02.17 CULTURALLY PROTECTED SOIL LANDSCAPE. PRIMARY
CONSTRUCTION ACCESS PATHWAY. PROVIDE 6MM VAPOR
BARRIER BELOW GEO-TEXTILE FABRIC WITH 4" OF
AGGREGATE BASE
02.52 OWNER PROVIDED AND INSTALLED PROTECTION OF
HISTORIC GRAFFITI. COORDINATE PROTECTION OF NEARBY
COLUMN SURFACES WITH NAMA'S ARCHITECTURAL
CONSERVATOR
02.53 PRESERVATION ZONE. CONSTRUCTION ACCESS IS LIMITED
TO WORK OCCURRING WITHIN THE ZONE. CARE SHOULD BE
TAKEN TO LIMIT THE AMOUNT OF DISTURBANCE IN THIS
AREA.
02.111 WALL AND COLUMN PROTECTION. EXTEND TO A HEIGHT
8'-0" ABOVE GRADE. SEE SPECIFICATIONS.
02.112 WALL AND COLUMN PROTECTION. EXTEND FULL HEIGHT
ABOVE GRADE. SEE SPECIFICATIONS.
02.152 EXIST SUMP PUMP TO REMAIN. IF ACCESS HATCH IS USED
DURING CONSTRUCTION, COORDINATE PROTECTION OF
SUMP PUMP WITH OWNER
02.153 TEMPORARY PROTECTION CHAIN LINK FENCE WITH
CONCRETE BLOCK BASE. OFFSET FROM HISTORIC
STRUCTURE MIN OF 12 INCHES.
SCALE OF FEET
16 32160
SCALE A
NO. REVISION DATE BY
B1 BID ADDENDUM 3 7/1/2022
| Sheets |
| A30 - UTILITY LEVEL RCP |
| A31 - EXHIBIT LEVEL RCP |
| A51 - NORTH & SOUTH ELEVATIONS |
| A82 - INTERIOR ELEVATIONS - ELEVATORS |
| A99 - CHAMBER LEVEL - ENLARGED PLANS |
| A100 - EXHIBIT LEVEL - ENLARGED RCP - ENTRY VESTIBULES |
| A101 - EXHIBIT LEVEL - ENLARGED RCP - SCREENING |
| A102 - EXHIBIT LEVEL - ENLARGED RCP - NORTH EXHIBIT |
| A103 - EXHIBIT LEVEL - ENLARGED RCP - CENTRAL EXHIBIT |
| A104 - EXHIBIT LEVEL - ENLARGED RCP - SOUTH EXHIBIT |
| A105 - EXHIBIT LEVEL - ENLARGED RCP - RETAIL |
| A106 - EXHIBIT LEVEL - ENLARGED RCP - NORTH EXIT AND BREAK ROOM |
| A107 - EXHIBIT LEVEL - ENLARGED RCP - TOILET |
| A108 - EXHIBIT LEVEL - ENLARGED RCP - UNISTRUT FRAME |
| A127 - INTERIOR ELEVATIONS - WOMEN'S & MEN'S TOILETS |
| A128 - INTERIOR ELEVATIONS - FAMILY & UNISEX TOILETS |
| A153 - MATERIAL SCHEDULE |
| A154 - FINISH SCHEDULE |
| G10 - TEMPORARY PROTECTION - INTERIOR - UTILITY LEVEL |
| G11 - TEMPORARY PROTECTION - INTERIOR - EXHIBIT LEVEL |
File details come from the government source that posted it. Updated .