A108_-_EXHIBIT_LEVEL_-_ENLARGED_RCP_-_UNISTRUT_FRAME_0009.pdf

PDF 1 MB Posted

Attached to
NAMA 216042 - Lincoln Memorial Rehabilitation
Solicitation number
140P2022R0046
Issued by

About this file

This document package includes construction plans and specifications for the Lincoln Memorial Rehabilitation project. The plans detail the installation of unistrut frames and acoustic panels on the exhibit level of the Lincoln Memorial Undercroft. Key aspects include installing unistrut frames secured to the existing concrete substrate, along with 1-inch acoustic panels in black mounted on the unistrut frames. Exhibit projectors and light fixtures are also specified. The related federal contract opportunity is solicitation number 140P2022R0046 from the National Park Service for the NAMA 216042 Lincoln Memorial Rehabilitation project.

View the file

Other files

File Type Posted
Sol_140P2022R0046_Amd_0011.pdf PDF
Sol_140P2022R0046_Amd_0010.pdf PDF
05_7000_-_DECORATIVE_METAL_0009.pdf PDF
28_05_00_01_Common_Results_for_Elect_Sec_Add_3_0009.pdf PDF
A31_-_EXHIBIT_LEVEL_RCP_0009.pdf PDF
M210_-_UTILITY_LEVEL_-_FIRE_PROTECTION_-_NW_PARTIAL_PLAN_0009.pdf PDF
A154_-_FINISH_SCHEDULE_0009.pdf PDF
01_2700_-_Contract_Line_Items_0009.pdf PDF
A101_-_EXHIBIT_LEVEL_-_ENLARGED_RCP_-_SCREENING_0009.pdf PDF
G6_0_(ADDENDUM_3)_0009.pdf PDF
G8_1_(ADDENDUM_3)_0009.pdf PDF
A82_-_INTERIOR_ELEVATIONS_-_ELEVATORS_0009.pdf PDF
01_3591_-_Historic_Preservation_Treatment_0009.pdf PDF
14_2100_Hydraulic_Elevators_0009.pdf PDF
E72_-_PANEL_SCHEDULES_0009.pdf PDF
C16_(ADDENDUM_3)_0009.pdf PDF
A128_-_INTERIOR_ELEVATIONS_-_FAMILY___UNISEX_TOILETS_0009.pdf PDF
E390_-_UTILITY_LEVEL_-_ENLARGED_PLAN__-_Addendum_3_0009.pdf PDF
07_1413_-_HOT_FLUID-APPLIED_RUBBERIZED_ASPHALT_WATERPROOFING_0009.pdf PDF
E45_-_EXHIBIT_LEVEL_-_CEILING_LIGHTING_-_SE_PARTIAL_PLAN_0009.pdf PDF
A100_-_EXHIBIT_LEVEL_-_ENLARGED_RCP_-_ENTRY_VESTIBULES_0009.pdf PDF
A104_-_EXHIBIT_LEVEL_-_ENLARGED_RCP_-_SOUTH_EXHIBIT_0009.pdf PDF
A99_-_CHAMBER_LEVEL_-_ENLARGED_PLANS_0009.pdf PDF
G11_-_TEMPORARY_PROTECTION_-_INTERIOR_-_EXHIBIT_LEVEL_0009.pdf PDF
A107_-_EXHIBIT_LEVEL_-_ENLARGED_RCP_-_TOILET_0009.pdf PDF
E46_-_EXHIBIT_LEVEL_-_CEILING_LIGHTING_-_NE_PARTIAL_PLAN_0009.pdf PDF
Sol_140P2022R0046_Amd_0009.pdf PDF
A30_-_UTILITY_LEVEL_RCP_0009.pdf PDF
A105_-_EXHIBIT_LEVEL_-_ENLARGED_RCP_-_RETAIL_0009.pdf PDF
A127_-_INTERIOR_ELEVATIONS_-_WOMEN_S___MEN_S_TOILETS_0009.pdf PDF
E54_-_EXHIBIT_LEVEL_-_WALL-BACK_LIGHTING_-_NE_PARTIAL_PLAN_2_0009.pdf PDF
G10_-_TEMPORARY_PROTECTION_-_INTERIOR_-_UTILITY_LEVEL_0009.pdf PDF
A103_-_EXHIBIT_LEVEL_-_ENLARGED_RCP_-_CENTRAL_EXHIBIT_0009.pdf PDF
A102_-_EXHIBIT_LEVEL_-_ENLARGED_RCP_-_NORTH_EXHIBIT_0009.pdf PDF
E14_-_EXHIBIT_LEVEL_-_POWER_-_SE_PARTIAL_PLAN_0009.pdf PDF
M208_-_UTILITY_LEVEL_-_FIRE_PROTECTION_-_NE_PARTIAL_PLAN_0009.pdf PDF
E361_-_SECURITY_DETAILS_-_Addendum_3_0009.pdf PDF
A106_-_EXHIBIT_LEVEL_-_ENLARGED_RCP_-_NORTH_EXIT_AND_BREAK_ROOM_0009.pdf PDF
A153_-_MATERIAL_SCHEDULE_0009.pdf PDF
A51_-_NORTH___SOUTH_ELEVATIONS_0009.pdf PDF
01_1100_-_Summary_of_Work_0009.pdf PDF
E15_-_EXHIBIT_LEVEL_-_POWER_-_NE_PARTIAL_PLAN_0009.pdf PDF
M201_-_UTILITY_LEVEL_-_FIRE_PROTECTION_PLAN_0009.pdf PDF
E360_-_SECURITY_DETAILS_-_Addendum_3_0009.pdf PDF
E53_-_EXHIBIT_LEVEL_-_WALL-BACK_LIGHTING_-_SE_PARTIAL_PLAN_2_0009.pdf PDF
C31_(ADDENDUM_3)_0009.pdf PDF
Sol_140P2022R0046_Amd_0008.pdf PDF
NAMA_LINC_216042_Bid_Questions_and_Responses_Vol_3_0008.pdf PDF
B08_Solit_Attachment__PriceSched-Rev_070522_0008.xlsx XLSX spreadsheet
Sol_140P2022R0046_Amd_0007.pdf PDF
Show 40 more

Latest 50 of 171 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C PA PA CPAPAPA

C

FS

PAPA

C

FS

CFS

FS

E X

E X

PA

C

C

C

C

PA

PA

C

PA

FS C

1. REFER TO A153 AND A154 FOR MATERIALS AND FINISHES

SCHEDULES

AP-2

ACOUSTIC

PLASTER

GWB- 1

GYPSUM BOARD

ACP-1

ACOUSTICAL

CEILING

PANEL

AP-1

ACOUSTIC

PLASTER

AP-3

ACOUSTIC

PLASTER

1'-4" 8'-7" ± 1'-4"

E Q

E Q

1'-1" 8'-7" ± 1'-4"

E Q

E

Q

26.01

EXHIBIT

SPINE

IMMERSIVE

FORUM

SOUTH

EXHIBIT

NORTH

EXHIBIT

20' - 5" AFF

EXPOSED

20' - 5" AFF

EXPOSED

20' - 5" AFF

EXPOSED

26.01

REFER TO A103

FOR LAYOUT

S A

S A

S A

26.01 26.01

21' - 11 3/8" AFF

19' - 9 3/8" AFF

21' - 11 3/8" AFF 21' - 11 3/8" AFF

4' - 0" TYP

(4

B A

Y S

EQ. 4' - 0" TYP EQ.

8" 9' - 0" 8' - 5 1/8" 10' - 0" 8' - 3" 9' - 0" 8"

EQ. 4' - 0" TYP EQ.

(4

B A

Y S

EQ. 4'-0" (18 bays) EQ.

/A

/A

:TYP.

26.01

S C

S C

S C

:TYP.

11.07

05.34

05.34

05.34

05.35

05.35

05.35

05.35

05.35

05.35

05.35

05.35

26.01

11.07

11.07 :TYP.

26.01

E Q

E Q

16' - 0" AFF

NORTH

EXHIBIT

ELEVATOR

ELV2

22' - 7" AFF

EXPOSED

/A

16' - 0" AFF

ELEVATOR

ELV1

SOUTH

EXHIBIT

/A

05.35

05.35

05.34

22' - 7" AFF

EXPOSED S

D

DOWN LIGHT FIXTURE

CEILING MOUNTED EXIT SIGN

FIRE ALARM SPEAKER STROBE

FIXED DOME CAMERA

FIXED MULTI IMAGER

EX

FS

C

C

DATE:

DESIGNED:

TECH. REVIEW:

SUB SHEET NO.

PMIS/PKG NO.

DRAWING NO.

SHEET

TITLE OF SHEET

OF

LEGEND

GENERAL NOTES

KEY NOTES

132917

NAMA-216042

SEAL

B

IM

L in c o ln

M e m o ri a l U n d e rc ro ft L in c o ln

M e m o ri a l_ A rc h U n d e rc ro ft .r v t

QE

QE

A108

EXHIBIT LEVEL -

ENLARGED RCP -

UNISTRUT FRAME

LINCOLN MEMORIAL REHABILITATION

NATIONAL MALL AND MEMORIAL PARKS

QE

5/13/2022 156

SCALE OF FEET

4 840

SCALE A

05.34 UNISTRUT FRAME - SECURE TO EXISTING CONCRETE

05.35 1" ACOUSTICAL PANEL (BLACK) ON UNISTRUT FRAME -

SECURED TO EXISTING CONCRETE

11.07 EXHIBIT PROJECTOR NIC

26.01 LIGHT FIXTURE. SEE ELECTRICAL DWGS.

SCALE AA108

1 EXHIBIT LEVEL RCP PLAN - UNISTRUT FRAME

SCALE AA108

3 EXHIBIT LEVEL RCP PLAN - UNISTRUT FRAME - NORTH

SCALE AA108

2 EXHIBIT LEVEL RCP PLAN - UNISTRUT FRAME - SOUTH

B1

NO. REVISION DATE BY

B1 BID ADDENDUM 3 7/1/2022

SEAL

Sheets
A30 - UTILITY LEVEL RCP
A31 - EXHIBIT LEVEL RCP
A51 - NORTH & SOUTH ELEVATIONS
A82 - INTERIOR ELEVATIONS - ELEVATORS
A99 - CHAMBER LEVEL - ENLARGED PLANS
A100 - EXHIBIT LEVEL - ENLARGED RCP - ENTRY VESTIBULES
A101 - EXHIBIT LEVEL - ENLARGED RCP - SCREENING
A102 - EXHIBIT LEVEL - ENLARGED RCP - NORTH EXHIBIT
A103 - EXHIBIT LEVEL - ENLARGED RCP - CENTRAL EXHIBIT
A104 - EXHIBIT LEVEL - ENLARGED RCP - SOUTH EXHIBIT
A105 - EXHIBIT LEVEL - ENLARGED RCP - RETAIL
A106 - EXHIBIT LEVEL - ENLARGED RCP - NORTH EXIT AND BREAK ROOM
A107 - EXHIBIT LEVEL - ENLARGED RCP - TOILET
A108 - EXHIBIT LEVEL - ENLARGED RCP - UNISTRUT FRAME
A127 - INTERIOR ELEVATIONS - WOMEN'S & MEN'S TOILETS
A128 - INTERIOR ELEVATIONS - FAMILY & UNISEX TOILETS
A153 - MATERIAL SCHEDULE
A154 - FINISH SCHEDULE
G10 - TEMPORARY PROTECTION - INTERIOR - UTILITY LEVEL
G11 - TEMPORARY PROTECTION - INTERIOR - EXHIBIT LEVEL

File details come from the government source that posted it. Updated .