A51_-_NORTH___SOUTH_ELEVATIONS_0009.pdf

PDF 1 MB Posted

Attached to
NAMA 216042 - Lincoln Memorial Rehabilitation
Solicitation number
140P2022R0046
Issued by

About this file

This document package includes construction drawings and specifications for the rehabilitation of the Lincoln Memorial Undercroft in Washington, D.C. The project involves renovations to the utility level, exhibit level, chamber level, and addition of temporary protections to interior spaces. Work includes repairs to the existing marble stylobate, stair walls, terrace walls, columns, and installation of fixed steel bar windows with steel grilles. The related federal contract opportunity is solicitation number 140P2022R0046 from the National Park Service seeking bids for the NAMA 216042 - Lincoln Memorial Rehabilitation project. The solicitation is for construction services at the Lincoln Memorial Undercroft.

View the file

Other files

File Type Posted
Sol_140P2022R0046_Amd_0011.pdf PDF
Sol_140P2022R0046_Amd_0010.pdf PDF
05_7000_-_DECORATIVE_METAL_0009.pdf PDF
28_05_00_01_Common_Results_for_Elect_Sec_Add_3_0009.pdf PDF
A31_-_EXHIBIT_LEVEL_RCP_0009.pdf PDF
M210_-_UTILITY_LEVEL_-_FIRE_PROTECTION_-_NW_PARTIAL_PLAN_0009.pdf PDF
A154_-_FINISH_SCHEDULE_0009.pdf PDF
01_2700_-_Contract_Line_Items_0009.pdf PDF
A101_-_EXHIBIT_LEVEL_-_ENLARGED_RCP_-_SCREENING_0009.pdf PDF
G6_0_(ADDENDUM_3)_0009.pdf PDF
G8_1_(ADDENDUM_3)_0009.pdf PDF
A82_-_INTERIOR_ELEVATIONS_-_ELEVATORS_0009.pdf PDF
01_3591_-_Historic_Preservation_Treatment_0009.pdf PDF
14_2100_Hydraulic_Elevators_0009.pdf PDF
E72_-_PANEL_SCHEDULES_0009.pdf PDF
C16_(ADDENDUM_3)_0009.pdf PDF
A128_-_INTERIOR_ELEVATIONS_-_FAMILY___UNISEX_TOILETS_0009.pdf PDF
E390_-_UTILITY_LEVEL_-_ENLARGED_PLAN__-_Addendum_3_0009.pdf PDF
07_1413_-_HOT_FLUID-APPLIED_RUBBERIZED_ASPHALT_WATERPROOFING_0009.pdf PDF
E45_-_EXHIBIT_LEVEL_-_CEILING_LIGHTING_-_SE_PARTIAL_PLAN_0009.pdf PDF
A100_-_EXHIBIT_LEVEL_-_ENLARGED_RCP_-_ENTRY_VESTIBULES_0009.pdf PDF
A104_-_EXHIBIT_LEVEL_-_ENLARGED_RCP_-_SOUTH_EXHIBIT_0009.pdf PDF
A99_-_CHAMBER_LEVEL_-_ENLARGED_PLANS_0009.pdf PDF
G11_-_TEMPORARY_PROTECTION_-_INTERIOR_-_EXHIBIT_LEVEL_0009.pdf PDF
A107_-_EXHIBIT_LEVEL_-_ENLARGED_RCP_-_TOILET_0009.pdf PDF
E46_-_EXHIBIT_LEVEL_-_CEILING_LIGHTING_-_NE_PARTIAL_PLAN_0009.pdf PDF
Sol_140P2022R0046_Amd_0009.pdf PDF
A30_-_UTILITY_LEVEL_RCP_0009.pdf PDF
A105_-_EXHIBIT_LEVEL_-_ENLARGED_RCP_-_RETAIL_0009.pdf PDF
A108_-_EXHIBIT_LEVEL_-_ENLARGED_RCP_-_UNISTRUT_FRAME_0009.pdf PDF
A127_-_INTERIOR_ELEVATIONS_-_WOMEN_S___MEN_S_TOILETS_0009.pdf PDF
E54_-_EXHIBIT_LEVEL_-_WALL-BACK_LIGHTING_-_NE_PARTIAL_PLAN_2_0009.pdf PDF
G10_-_TEMPORARY_PROTECTION_-_INTERIOR_-_UTILITY_LEVEL_0009.pdf PDF
A103_-_EXHIBIT_LEVEL_-_ENLARGED_RCP_-_CENTRAL_EXHIBIT_0009.pdf PDF
A102_-_EXHIBIT_LEVEL_-_ENLARGED_RCP_-_NORTH_EXHIBIT_0009.pdf PDF
E14_-_EXHIBIT_LEVEL_-_POWER_-_SE_PARTIAL_PLAN_0009.pdf PDF
M208_-_UTILITY_LEVEL_-_FIRE_PROTECTION_-_NE_PARTIAL_PLAN_0009.pdf PDF
E361_-_SECURITY_DETAILS_-_Addendum_3_0009.pdf PDF
A106_-_EXHIBIT_LEVEL_-_ENLARGED_RCP_-_NORTH_EXIT_AND_BREAK_ROOM_0009.pdf PDF
A153_-_MATERIAL_SCHEDULE_0009.pdf PDF
01_1100_-_Summary_of_Work_0009.pdf PDF
E15_-_EXHIBIT_LEVEL_-_POWER_-_NE_PARTIAL_PLAN_0009.pdf PDF
M201_-_UTILITY_LEVEL_-_FIRE_PROTECTION_PLAN_0009.pdf PDF
E360_-_SECURITY_DETAILS_-_Addendum_3_0009.pdf PDF
E53_-_EXHIBIT_LEVEL_-_WALL-BACK_LIGHTING_-_SE_PARTIAL_PLAN_2_0009.pdf PDF
C31_(ADDENDUM_3)_0009.pdf PDF
Sol_140P2022R0046_Amd_0008.pdf PDF
NAMA_LINC_216042_Bid_Questions_and_Responses_Vol_3_0008.pdf PDF
B08_Solit_Attachment__PriceSched-Rev_070522_0008.xlsx XLSX spreadsheet
Sol_140P2022R0046_Amd_0007.pdf PDF
Show 40 more

Latest 50 of 171 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EXHIBIT LEVEL

34' - 4 7/8"

CHAMBER LEVEL

57' - 8 7/8"±

LOWER ROOF

113' - 11 15/16"±

UPPER ROOF

125' - 6 7/16"±

A62

BCDGHLM EFJKNOP A

NORTH EXIT LANDING

29' - 9 7/8"

A58

A51

A63

/2

N.1 L.1

A64

02.147

:TYP.

02.75

:TYP.

02.134

:TYP.

02.128

:TYP.

02.146

:TYP.

02.45

NEW NORTH EXIT

STAIR LANDING 1

77' - 4 7/8"±

STAIR LANDING 2

97' - 0 7/8"±

STAIR LANDING 3

116' - 10 15/16"±

EXHIBIT LEVEL

34' - 4 7/8"

CHAMBER LEVEL

57' - 8 7/8"±

LOWER ROOF

113' - 11 15/16"±

UPPER ROOF

125' - 6 7/16"±

A62

B C D G H L ME F J K N O PA

05.08

A63

/2

N.1L.1

A64

:TYP.

02.146

:TYP.

02.45

:TYP.

02.128

:TYP.

02.134

:TYP.

02.75

02.147

STAIR LANDING 1

77' - 4 7/8"±

STAIR LANDING 2

97' - 0 7/8"±

STAIR LANDING 3

116' - 10 15/16"±

V

IF

VIF

8' - 6"

B1

1. SEE G SHEETS AND SPECIFICATIONS FOR PROTECTION

TERRACE WALL, MARBLE COLUMNS AND STYLOBATE.

DATE:

DESIGNED:

TECH. REVIEW:

SUB SHEET NO.

PMIS/PKG NO.

DRAWING NO.

SHEET

TITLE OF SHEET

OF

LEGEND

GENERAL NOTES

KEY NOTES

132917

NAMA-216042

SEAL

B

IM

L in c o ln

M e m o ri a l U n d e rc ro ft L in c o ln

M e m o ri a l_ A rc h U n d e rc ro ft .r v t

QE

QE

A51

NORTH & SOUTH

ELEVATIONS

LINCOLN MEMORIAL REHABILITATION

NATIONAL MALL AND MEMORIAL PARKS

QE

5/13/2022 113SCALE AA51

1 NORTH ELEVATION

SCALE OF FEET

16 32160

SCALE A

02.45 EXISTING MARBLE STYLOBATE TO REMAIN. PROVIDE

PROTECTION THROUGH OUT CONSTRUCTION. SEE G

SHEETS

02.75 EXISTING GRANITE STAIR WALL. PROVIDE PROTECTION.

02.128 EXISTING RAISED TERRACE WALL TO REMAIN. PROVIDE

SHORING AND STABILIZATION AS REQUIRED DURING

CONSTRUCTION TO COMPLETE THE WORK. REVIEW ALL

TEMPORARY PROTECTION WITH COR.

02.134 EXISTING MARBLE STAIR STRINGER TO REMAIN.

PROVIDE PROTECTION THROUGHOUT CONSTRUCTION.

SEE G SHEETS.

02.146 EXIST MARBLE FLUTED COLUMNS. PROTECT AT ALL

TIMES DURING CONSTRUCTION.

02.147 EXISTING WAY-FINDING PYLON TO REMAIN

05.08 FIXED STEEL BAR WINDOW GUARD WITH STEEL GRILLE

TO MATCH EXISTING. PAINT WITH TNEMEC PAINT.

SCALE AA51

2 SOUTH ELEVATION

NO. REVISION DATE BY

B1 BID ADDENDUM 3 7/1/2022

SEAL

Sheets
A30 - UTILITY LEVEL RCP
A31 - EXHIBIT LEVEL RCP
A51 - NORTH & SOUTH ELEVATIONS
A82 - INTERIOR ELEVATIONS - ELEVATORS
A99 - CHAMBER LEVEL - ENLARGED PLANS
A100 - EXHIBIT LEVEL - ENLARGED RCP - ENTRY VESTIBULES
A101 - EXHIBIT LEVEL - ENLARGED RCP - SCREENING
A102 - EXHIBIT LEVEL - ENLARGED RCP - NORTH EXHIBIT
A103 - EXHIBIT LEVEL - ENLARGED RCP - CENTRAL EXHIBIT
A104 - EXHIBIT LEVEL - ENLARGED RCP - SOUTH EXHIBIT
A105 - EXHIBIT LEVEL - ENLARGED RCP - RETAIL
A106 - EXHIBIT LEVEL - ENLARGED RCP - NORTH EXIT AND BREAK ROOM
A107 - EXHIBIT LEVEL - ENLARGED RCP - TOILET
A108 - EXHIBIT LEVEL - ENLARGED RCP - UNISTRUT FRAME
A127 - INTERIOR ELEVATIONS - WOMEN'S & MEN'S TOILETS
A128 - INTERIOR ELEVATIONS - FAMILY & UNISEX TOILETS
A153 - MATERIAL SCHEDULE
A154 - FINISH SCHEDULE
G10 - TEMPORARY PROTECTION - INTERIOR - UTILITY LEVEL
G11 - TEMPORARY PROTECTION - INTERIOR - EXHIBIT LEVEL