About this file
This document includes construction drawings and specifications for the Lincoln Memorial Rehabilitation project. The project involves repairs and restoration of stone surfaces, doors, and frames within the Lincoln Memorial undercroft spaces on the chamber and exhibit levels. Work includes cleaning, patching and repairing plaster, repairing cracks in stone door surrounds, restoring salvaged bronze doors and frames, and other minor upgrades to mechanical and plumbing systems. Bidding opportunities are also included for optional stone repair work and door restoration. The related federal contract solicitation is for the NAMA 216042 Lincoln Memorial Rehabilitation project being conducted by the National Park Service. The solicitation includes repair and restoration of the Lincoln Memorial undercroft areas per the specifications in the construction drawings provided.
View the file
Other files
Show 40 more
Latest 50 of 171 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UPU.C.
Refr.
C C
1. SEE A150 TO A152 FOR PARTITION TYPES.
2. SEE A155, A156, AND A160 FOR DOOR AND WINDOW
SCHEDULES.
3. SEE A153 AND A154 FOR MATERIALS AND FINISHES.
4. SEE A126 FOR TYPICAL MOUNTING HEIGHTS.
6 7
E
A12811
A128
08.01
/4
2' - 4" 2' - 7 1/2"
S2B
TA-9
08.03
22.15
:SEE HAZMAT DWG FOR
LEAD PT REMOVAL
16' - 4 1/8" ± 16' - 4 1/2" ±
201.1
EX011
201.2201.3
201A.1
EXISTING
HANDRYER TO
REMAIN
EXISTING SINK
TO REMAIN
B2
12 13 14
E
A12817
A128
08.01
TA-22
TA-20
TA-19
TA-10 7' - 4" 2' - 4"
S2B
02.89 08.03
04.08
08.17
22.15
:SEE HAZMAT DWG FOR
LEAD PT REMOVAL
10.39
11.09
06.02
:COORD. GROMMET
LOCATION WITH EQUIPMENT
16' - 5" ± 16' - 4 3/8" ±
203A.1
203.3
203.2
203.1
A87
4' - 9"
:OVER EXIST. OPENING
/8
6 7 8
K
A1252
S1D
22.04
08.01 3' - 6"
S2B
E Q
E Q
2' - 8" ±
22.15
22.16
16' - 4 3/4" ± 16' - 8" ±
CORNER
GUARD
B1
12 13
K
A125 75
:TYP.
02.41
:TYP.
08.01
S1D
10' - 8 1/2"
4' - 1"
E Q
E Q
S2B
22.15
16' - 11 1/4" ± 16' - 5" ±
09.0909.09
02.100
CORNER
GUARD B1
04.08
04.08
DATE:
DESIGNED:
TECH. REVIEW:
SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
TITLE OF SHEET
OF
LEGEND
GENERAL NOTES
KEY NOTES
132917
NAMA-216042
SEAL
B
IM
L in c o ln
M e m o ri a l U n d e rc ro ft L in c o ln
M e m o ri a l_ A rc h U n d e rc ro ft .r v t
QE
QE
A99
CHAMBER LEVEL -
ENLARGED PLANS
LINCOLN MEMORIAL REHABILITATION
NATIONAL MALL AND MEMORIAL PARKS
QE
5/13/2022 147
SCALE OF FEET
4 840
SCALE A
SCALE AA99A20
3 CHAMBER LEVEL - CULTURAL RESOURCES
SCALE AA99A21
4 CHAMBER LEVEL - USPP BOOTH
SCALE AA99A18
1 CHAMBER LEVEL - SOUTH ELEVATOR LOBBY
SCALE AA99A19
2 CHAMBER LEVEL - NORTH ELEVATOR LOBBY
02.41 METAL SHIP LADDER, EXISTING TO REMAIN
02.89 EXISTING CONCRETE STAIR TO REMAIN
02.100 EXISTING WINDOW NIC. PROTECT DURING
CONSTRUCTION.
04.08 REPAIR CRACKS IN STONE DOOR SURROUND. SUBMIT
PLAN TO OWNER FOR APPROVAL PRIOR TO REPAIR. BID
OPTION I.
06.02 SOLID SURFACE COUNTERTOP
08.01 CLEAN, RESTORE AND REINSTALL SALVAGED BRONZE
DOOR. BID OPTION C
08.03 CLEAN AND RESTORE EXISTING BRONZE DOOR FRAME
AND TRANSOM. BID OPTION C.
08.17 FLOOR ACCESS HATCH
09.09 PATCH AND REPAIR EXISTING PLASTER
10.39 TWO-TIER LOCKERS
11.09 UNDER COUNTER REFRIGERATOR (OFOI)
22.04 MOP SINK
22.15 6" STORM RISER. LOCATE AT EXISTING PENETRATION.
SEE PLUMBING DRAWINGS
22.16 WATER HEATER. SEE PLUMBING DRAWINGS
NO SCALEA99
5 ROOM 203 - STONE REPAIR (BID OPT. I)
NO. REVISION DATE BY
B1 BID ADDENDUM 2 6/24/2022 QE
B2 BID ADDENDUM 3 7/1/2022
SEAL
| Sheets |
| A30 - UTILITY LEVEL RCP |
| A31 - EXHIBIT LEVEL RCP |
| A51 - NORTH & SOUTH ELEVATIONS |
| A82 - INTERIOR ELEVATIONS - ELEVATORS |
| A99 - CHAMBER LEVEL - ENLARGED PLANS |
| A100 - EXHIBIT LEVEL - ENLARGED RCP - ENTRY VESTIBULES |
| A101 - EXHIBIT LEVEL - ENLARGED RCP - SCREENING |
| A102 - EXHIBIT LEVEL - ENLARGED RCP - NORTH EXHIBIT |
| A103 - EXHIBIT LEVEL - ENLARGED RCP - CENTRAL EXHIBIT |
| A104 - EXHIBIT LEVEL - ENLARGED RCP - SOUTH EXHIBIT |
| A105 - EXHIBIT LEVEL - ENLARGED RCP - RETAIL |
| A106 - EXHIBIT LEVEL - ENLARGED RCP - NORTH EXIT AND BREAK ROOM |
| A107 - EXHIBIT LEVEL - ENLARGED RCP - TOILET |
| A108 - EXHIBIT LEVEL - ENLARGED RCP - UNISTRUT FRAME |
| A127 - INTERIOR ELEVATIONS - WOMEN'S & MEN'S TOILETS |
| A128 - INTERIOR ELEVATIONS - FAMILY & UNISEX TOILETS |
| A153 - MATERIAL SCHEDULE |
| A154 - FINISH SCHEDULE |
| G10 - TEMPORARY PROTECTION - INTERIOR - UTILITY LEVEL |
| G11 - TEMPORARY PROTECTION - INTERIOR - EXHIBIT LEVEL |
File details come from the government source that posted it. Updated .