INTERNAL INSPECTION LOG
FLow Measurement
Date: 2/26/2010
Technician: ADS
ADS Environmental Services
16H3-077CBN 16H3-077CDN
Downstream Line Depth NA
Sewer Plug Locations
None
Dyed-Water Flood Sketch None
Upstream Line Depth NA
ADDITIONAL INFORMATION
Type Of Sewer Combined
Harlem Baden Hebert
LOCATION: Junk yard off Kienlen Ave.
PROJECT:
Total Line Length 139
Type Of Pipe RCP
Joint Spacing 4
Pipe Diameter 42
Avg. Depth
Uncapped SC's
Comments: Dataview shows"16H3-077CBN to 16G4-319CA " -- Should show "16H3- 077CBN to 16H3-077CDN" -- Inspection of North line
TAPE NO. 32
Start Counter 03
End Counter ft.
ft. in.
in.
l.f.
l.f.
in.
ft.TV Line Length 139 l.f.
Time: 10:30 AM
Precleaning N
Upstream Structure Downstream Structure
Start Inspection End Inspection
Capped SC's
Distance Defect Description Clock Ref.
GPM Photo No.
Defect
0 SNP 16H3-077CBN 1BAND
2-137 Minimal to No Water in Pipe W
ALIGN
2-137 Minimal to No Debris in Pipe
SGR
DEBRIS
14 7Tap - Break-in - Cannot effectively evaluate -- No protrusion -- 12-inch VCP
TBX 3
LAT'L
17 10Tap - Break-in - Structural Damage (slight-moder.) -- No protrusion -- 15-inch VCP -- Cracked pipe
TBS 2
LAT'L
24-137 Evidence of Leakage -- Slight -- MD's at most joints
EL 1
LEAK
39-42 Bend to Right (moderate -- 45-60 degrees) 4
BR 3
ALIGN
44 9Leak At Joint (See I/I Severity Value)
LJ
LEAK
44 Leak - GW Infiltration (Slight <1 gpm) .50
IGW 2
LEAK
54 General Condition Photo 5GCP
62 10Leak At Joint (See I/I Severity Value) 6
LJ
LEAK
62 Leak - GW Infiltration (Slight <1 gpm) .25
IGW 2
LEAK
Page 1 of 4 From MH16H3-077CBNTo 16H3-077CDN
Distance Defect Description Clock Ref.
GPM Photo No.
Defect
73-97 Bend to Left (slight -- <15 degrees)
BL 1
ALIGN
115 3Longitudinal Crack (slight-moderate) 7
CFL 2
CRACK
115 Leak At Crack/Fracture (See I/I Severity) -- Heavy MD's at crack
LCF
LEAK
115 Leak - GW Infiltration (Seepage) .01
IGW 1
LEAK
139 New Structure -- Not on Prints -- BuriedNEWB
139 MH 16H3-077CN (Buried) 8EDMH
Page 2 of 4 From MH16H3-077CBNTo 16H3-077CDN
LS 16H3-077CBN to 16H3-077CDN
Harlem Baden Hebert TV PHOTOS
FLow Measurement
0 l.f.PHOTO 1 Inspection Begins at Connection/Node --
SNP 16H3-077CBN
14 l.f.PHOTO 2 Tap - Break-in - Cannot effectively evaluate -- No protrusion -- 12-inch VCP
17 l.f.PHOTO 3 Tap - Break-in - Structural Damage (slight-moder.) -- Cracked pipe -- No protrusion --
15-inch VCP
39-42 l.f.PHOTO 4 Bend to Right (moderate -- 45-60 degrees)
54 l.f.PHOTO 5 General Condition Photo 62 l.f.PHOTO 6 Leak At Joint (See I/I Severity Value)
Page 3 of 4 From MH16H3-077CBNTo 16H3-077CDN
115 l.f.PHOTO 7 Longitudinal Crack (slight-moderate) 139 l.f.PHOTO 8 MH 16H3-077CN (Buried)
Page 4 of 4 From MH16H3-077CBNTo 16H3-077CDN