INTERNAL INSPECTION LOG
FLow Measurement
Date: 2/11/2010
Technician: ADS
ADS Environmental Services
16G4-289C 16G4-280C
Downstream Line Depth NA
Sewer Plug Locations
None
Dyed-Water Flood Sketch None
Upstream Line Depth NA
ADDITIONAL INFORMATION
Type Of Sewer Sanitary
Harlem Baden Hebert
LOCATION: Easement Hamilton Avenue
PROJECT:
Total Line Length 411
Type Of Pipe RCP
Joint Spacing 0
Pipe Diameter 72x84
Avg. Depth
Uncapped SC's
Comments:
TAPE NO. 18
Start Counter 00000
End Counter 01355 ft.
ft. in.
in.
l.f.
l.f.
in.
ft.TV Line Length 411 l.f.
Time: 1:20 PM
Precleaning N
Upstream Structure Downstream Structure
Start Inspection End Inspection
Capped SC's
Distance Defect Description Clock Ref.
GPM Photo No.
Defect
0 MH 16G4-289C 1BUMH
2-409 Less Than 1/8-Pipe Water Depth W 1
ALIGN
2-409 Minimal to No Debris in Pipe
SGR
DEBRIS
2-409 Evidence of Leakage -- Slight
EL 1
LEAK
60 General Condition Photo 2GCP
133 General Condition Photo 3GCP
205 General Condition Photo 4GCP
235 3Tap - Break-in - Fair Condition -- 3" protrusion -- 18-inch VCP 5
TB 2
LAT'L
250 10Leak in Brickwork/Masonry (See I/I Severity Value) 6
LB
LEAK
250 Leak - GW Infiltration (Slight <1 gpm) 0.2
IGW 2
LEAK
272 2Tap - Capped - Fair Condition -- No protrusion -- 24-inch VCP 7
TC 2
LAT'L
290 Bend to Left (slight-moderate -- 15-45 degrees)
BL 2
ALIGN
Page 1 of 4 From MH 16G4-289C To 16G4-280C
Distance Defect Description Clock Ref.
GPM Photo No.
Defect
301-356 5Leak in Brickwork/Masonry (See I/I Severity Value) 8
LB
LEAK
301 Leak - GW Infiltration (Moderate 1-5 gpm) 4
IGW 3
LEAK
366 General Condition Photo 9GCP
411 MH 16G4-280C 10EDMH
Page 2 of 4 From MH 16G4-289C To 16G4-280C
LS 16G4-289C to 16G4-280C
Harlem Baden Hebert TV PHOTOS
FLow Measurement
0 l.f.PHOTO 1 MH 16G4-289C 60 l.f.PHOTO 2 General Condition Photo
133 l.f.PHOTO 3 General Condition Photo 205 l.f.PHOTO 4 General Condition Photo
235 l.f.PHOTO 5 Tap - Break-in - Fair Condition -- 3" protrusion -- 18-inch VCP
250 l.f.PHOTO 6 Leak in Brickwork/Masonry (See I/I Severity Value)
Page 3 of 4 From MH 16G4-289C To 16G4-280C
272 l.f.PHOTO 7 Tap - Capped - Fair Condition -- No protrusion -- 24-inch VCP
301-356 l.f.PHOTO 8 Leak in Brickwork/Masonry (See I/I Severity Value)
366 l.f.PHOTO 9 General Condition Photo 411 l.f.PHOTO 10 MH 16G4-280C
Page 4 of 4 From MH 16G4-289C To 16G4-280C