Text version
INTERNAL INSPECTION LOG
FLow Measurement
Date: 2/11/2010
Technician: ADS
ADS Environmental Services
16H2-030C 16H2-100C
Downstream Line Depth NA
Sewer Plug Locations
None
Dyed-Water Flood Sketch None
Upstream Line Depth 9 6
ADDITIONAL INFORMATION
Type Of Sewer Combination
Harlem Baden Hebert
LOCATION: Esmt off Cherry Avenue
PROJECT:
Total Line Length 630
Type Of Pipe RCP
Joint Spacing 0
Pipe Diameter 48x48
Avg. Depth
Uncapped SC's
Comments:
TAPE NO. 15
Start Counter 00000
End Counter 05234 ft.
ft. in.
in.
l.f.
l.f.
in.
ft.TV Line Length 630 l.f.
Time: 10:05 AM
Precleaning N
Upstream Structure Downstream Structure
Start Inspection End Inspection
Capped SC's
Distance Defect Description Clock Ref.
GPM Photo No.
Defect
0 MH 16H2-030C 1BUMH
2-628 Less Than 1/8-Pipe Water Depth W 1
ALIGN
2-628 Sludge/Sand & Grit (10-25% dia.)
SGR 2
DEBRIS
2 Moderate to Severe Corrosion/Erosion 2
SR 4
DETER
12 3Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch
VCP
TB 1
LAT'L
27 9Tap - Break-in - Fair to Good Condition -- No protrusion -- 12-inch VCP
TB 1
LAT'L
28 Evidence of Leakage -- Slight to Moderate -- MD's 5
EL 2
LEAK
58 Bend to Left (slight-moderate -- 15-45 degrees) 6
BL 2
ALIGN
63 11Tap - Break-in - Fair to Good Condition -- 1" protrusion -- 6-inch
VCP
TB 1
LAT'L
84 9Tap - Break-in - Debris & Grease (light-medium) -- No protrusion -- 6-inch VCP
TBD 2
LAT'L
95 12Tap - Break-in - Fair to Good Condition -- 4" protrusion -- 6-inch
VCP
TB 1
LAT'L
98 12Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch
VCP
TB 1
LAT'L
Page 1 of 10 From MH 16H2-030C To 16H2-100C
Distance Defect Description Clock Ref.
GPM Photo No.
Defect
110 General Condition Photo 11GCP
140 Leak At Hole/Void in Pipe (See I/I Severity) -- No void possible plug
LHV
LEAK
140 Leak - GW Infiltration (Seepage) -- Fast drip 0.02
IGW 1
LEAK
175 12Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch
VCP
TB 1
LAT'L
176 3Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch
VCP
TB 1
LAT'L
178 12Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch
VCP
TB 1
LAT'L
200 General Condition Photo 16GCP
217 Unknown structure -- Not on map 17GCC
220 12Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch
VCP
TB 1
LAT'L
220 Leak At/Around Lateral (See I/I Severity Value)
LAL
LEAK
220 Leak - GW Infiltration (Slight <1 gpm) 0.25
IGW 2
LEAK
251 General Condition Photo 19GCP
261 12Tap - Capped - Fair-Poor Condition -- No protrusion -- 6-inch VCP 20
TC 3
LAT'L
262 11Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch
VCP
TB 1
LAT'L
279 12Tap - Break-in - Fair to Good Condition -- 4" protrusion -- 6-inch
VCP
TB 1
LAT'L
300 General Condition Photo 23GCP
338 12Tap - Capped - Fair to Good Condition -- No protrusion -- 6-inch
VCP
TC 1
LAT'L
339 11Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch
VCP
TB 1
LAT'L
352 12Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch
VCP
TB 1
LAT'L
385 12Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch
VCP
TB 1
LAT'L
395 12Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch
VCP
TB 1
LAT'L
405 12Tap - Break-in - Fair to Good Condition -- No protrusion -- 15-inch VCP
TB 1
LAT'L
414 Bend to Left (slight-moderate -- 15-45 degrees) 30
BL 2
ALIGN
419 11Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch
VCP
TB 1
LAT'L
Page 2 of 10 From MH 16H2-030C To 16H2-100C
Distance Defect Description Clock Ref.
GPM Photo No.
Defect
422 7Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch
VCP
TB 1
LAT'L
422 Pipe Shape or Size Change -- Changes to 36x48PSIZ
462 7Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch
VCP
TB 1
LAT'L
501 General Condition Photo 34GCP
605 9Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch
VCP
TB 1
LAT'L
608 11Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch
VCP
TB 1
LAT'L
624 Bend to Right (slight-moderate -- 15-45 degrees) 37
BR 2
ALIGN
630 MH 16H2-100C 38EDMH
Page 3 of 10 From MH 16H2-030C To 16H2-100C
LS 16H2-030C to 16H2-100C
Harlem Baden Hebert TV PHOTOS
FLow Measurement
0 l.f.PHOTO 1 MH 16H2-030C 2 l.f.PHOTO 2 Moderate to Severe Corrosion/Erosion
12 l.f.PHOTO 3 Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch VCP
27 l.f.PHOTO 4 Tap - Break-in - Fair to Good Condition -- No protrusion -- 12-inch VCP
28 l.f.PHOTO 5 Evidence of Leakage -- Slight to Moderate -- MD's
58 l.f.PHOTO 6 Bend to Left (slight-moderate -- 15-45 degrees)
Page 4 of 10 From MH 16H2-030C To 16H2-100C
63 l.f.PHOTO 7 Tap - Break-in - Fair to Good Condition -- 1" protrusion -- 6-inch VCP
84 l.f.PHOTO 8 Tap - Break-in - Debris & Grease (light-medium) -- No protrusion -- 6-inch VCP
95 l.f.PHOTO 9 Tap - Break-in - Fair to Good Condition -- 4" protrusion -- 6-inch VCP
98 l.f.PHOTO 10 Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch VCP
110 l.f.PHOTO 11 General Condition Photo 140 l.f.PHOTO 12 Leak At Hole/Void in Pipe (See I/I Severity) -- No void possible plug
Page 5 of 10 From MH 16H2-030C To 16H2-100C
175 l.f.PHOTO 13 Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch VCP
176 l.f.PHOTO 14 Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch VCP
178 l.f.PHOTO 15 Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch VCP
200 l.f.PHOTO 16 General Condition Photo
217 l.f.PHOTO 17 Unknown structure -- Not on map 220 l.f.PHOTO 18 Tap - Break-in - Fair to Good Condition --
Page 6 of 10 From MH 16H2-030C To 16H2-100C
251 l.f.PHOTO 19 General Condition Photo 261 l.f.PHOTO 20 Tap - Capped - Fair-Poor Condition -- No protrusion -- 6-inch VCP
262 l.f.PHOTO 21 Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch VCP
279 l.f.PHOTO 22 Tap - Break-in - Fair to Good Condition -- 4" protrusion -- 6-inch VCP
300 l.f.PHOTO 23 General Condition Photo 338 l.f.PHOTO 24 Tap - Capped - Fair to Good Condition --
Page 7 of 10 From MH 16H2-030C To 16H2-100C
339 l.f.PHOTO 25 Tap - Break-in - Fair to Good Condition --
352 l.f.PHOTO 26 Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch VCP
385 l.f.PHOTO 27 Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch VCP
395 l.f.PHOTO 28 Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch VCP
405 l.f.PHOTO 29 Tap - Break-in - Fair to Good Condition -- No protrusion -- 15-inch VCP
414 l.f.PHOTO 30 Bend to Left (slight-moderate -- 15-45
Page 8 of 10 From MH 16H2-030C To 16H2-100C
419 l.f.PHOTO 31 Tap - Break-in - Fair to Good Condition --
422 l.f.PHOTO 32 Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch VCP
462 l.f.PHOTO 33 Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch VCP
501 l.f.PHOTO 34 General Condition Photo
605 l.f.PHOTO 35 Tap - Break-in - Fair to Good Condition -- No protrusion -- 6-inch VCP
608 l.f.PHOTO 36 Tap - Break-in - Fair to Good Condition --
Page 9 of 10 From MH 16H2-030C To 16H2-100C
624 l.f.PHOTO 37 Bend to Right (slight-moderate -- 15-45
630 l.f.PHOTO 38 MH 16H2-100C
Page 10 of 10 From MH 16H2-030C To 16H2-100C
File details come from the government source that posted it.