INTERNAL INSPECTION LOG
FLow Measurement
Date: 2/26/2010
Technician: ADS
ADS Environmental Services
16G4-319CA 16G4-319C
Downstream Line Depth NA
Sewer Plug Locations
None
Dyed-Water Flood Sketch None
Upstream Line Depth NA
ADDITIONAL INFORMATION
Type Of Sewer Combined
Harlem Baden Hebert
LOCATION: Easemet off Hamilton Ave.
PROJECT:
Total Line Length 103
Type Of Pipe RCP
Joint Spacing 0
Pipe Diameter 84x72
Avg. Depth
Uncapped SC's
Comments:
TAPE NO. 32
Start Counter 08
End Counter ft.
ft. in.
in.
l.f.
l.f.
in.
ft.TV Line Length 103 l.f.
Time: 12:15 PM
Precleaning N
Upstream Structure Downstream Structure
Start Inspection End Inspection
Capped SC's
Distance Defect Description Clock Ref.
GPM Photo No.
Defect
0 SNP 16G4-319CA 1BAND
2-101 Minimal to No Water in Pipe W
ALIGN
2-101 Minimal to No Debris in Pipe
SGR
DEBRIS
2-65 4Longitudinal Crack (slight-moderate) 2
CFL 2
CRACK
10-17 8Longitudinal Crack (minor/hairline) 3
CFL 1
CRACK
21 General Condition Photo 4GCP
65 Pipe Shape or Size Change -- Reduces to 60 x 60-inch 5PSIZ
80 2Tap - Break-in - Fair Condition -- No protrusion -- 24-inch VCP 6
TB 2
LAT'L
88-103 4-8Evidence of Leakage -- Slight -- MD's throughout pipe 7
EL 1
LEAK
103 MH 16G4-319C 8EDMH
Page 1 of 3 From MH 16G4-319CA To 16G4-319C
LS 16G4-319CA to 16G4-319C
Harlem Baden Hebert TV PHOTOS
FLow Measurement
0 l.f.PHOTO 1 Inspection Begins at Connection/Node --
SNP 16G4-319CA
2-65 l.f.PHOTO 2 Longitudinal Crack (slight-moderate)
10-17 l.f.PHOTO 3 Longitudinal Crack (minor/hairline) 21 l.f.PHOTO 4 General Condition Photo
65 l.f.PHOTO 5 Pipe Shape or Size Change -- Reduces to 60 x 60-inch
80 l.f.PHOTO 6 Tap - Break-in - Fair Condition -- No protrusion -- 24-inch VCP
Page 2 of 3 From MH 16G4-319CA To 16G4-319C
88-103 l.f.PHOTO 7 Evidence of Leakage -- Slight -- MD's throughout pipe
103 l.f.PHOTO 8 MH 16G4-319C
Page 3 of 3 From MH 16G4-319CA To 16G4-319C