INTERNAL INSPECTION LOG
FLow Measurement
Date: 2/26/2010
Technician: ADS
ADS Environmental Services
16G4-319C 16G4-284CA
Downstream Line Depth NA
Sewer Plug Locations
None
Dyed-Water Flood Sketch None
Upstream Line Depth NA
ADDITIONAL INFORMATION
Type Of Sewer Combined
Harlem Baden Hebert
LOCATION: Easemet off Hamilton Ave.
PROJECT:
Total Line Length 850
Type Of Pipe RCP
Joint Spacing 0
Pipe Diameter 60x60
Avg. Depth
Uncapped SC's
Comments:
TAPE NO. 32
Start Counter 09
End Counter ft.
ft. in.
in.
l.f.
l.f.
in.
ft.TV Line Length 850 l.f.
Time: 12:30 PM
Precleaning N
Upstream Structure Downstream Structure
Start Inspection End Inspection
Capped SC's
Distance Defect Description Clock Ref.
GPM Photo No.
Defect
0 MH 16G4-319C 1BUMH
2-848 Minimal to No Water in Pipe W
ALIGN
2-848 Minimal to No Debris in Pipe
SGR
DEBRIS
2-848 4-8Evidence of Leakage -- Slight -- MD's throughout pipe 2
EL 1
LEAK
2-53 Bend to Right (slight -- <15 degrees)
BR 1
ALIGN
53 4Tap - Capped - Structural Damage (moderate) -- No protrusion -- 24-inch VCP
TCS 3
LAT'L
53 Leak in/from Lateral -- Visible (See I/I Severity) -- At cap 4
LLV
LEAK
53 Leak - GW Infiltration (Moderate 1-5 gpm) 1.0
IGW 3
LEAK
53 General Condition Photo 5GCP
102 2Leak in Brickwork/Masonry (See I/I Severity Value) 6
LB
LEAK
102 Leak - GW Infiltration (Slight <1 gpm) .10
IGW 2
LEAK
106 2Leak in Brickwork/Masonry (See I/I Severity Value) 7
LB
LEAK
Page 1 of 16 From MH 16G4-319C To 16G4-284CA
Distance Defect Description Clock Ref.
GPM Photo No.
Defect
106 Leak - GW Infiltration (Slight <1 gpm) .15
IGW 2
LEAK
108 1Leak in Brickwork/Masonry (See I/I Severity Value) 8
LB
LEAK
108 Leak - GW Infiltration (Seepage) .02
IGW 1
LEAK
120 9Moderate Corrosion/Erosion -- Exposed rebar 9
SR 3
DETER
146-151 12Leak in Brickwork/Masonry (See I/I Severity Value) 10
LB
LEAK
146-151 Leak - GW Infiltration (Slight <1 gpm) .20
IGW 2
LEAK
151 General Condition Photo 11GCP
159 1-2Leak in Brickwork/Masonry (See I/I Severity Value) 12
LB
LEAK
159 Leak - GW Infiltration (Slight <1 gpm) .15
IGW 2
LEAK
170 10Tap - Break-in - Fair Condition -- 4" protrusion -- 15-inch VCP 13 &
14TB 2
LAT'L
237 General Condition Photo 15GCP
276 3Leak in Brickwork/Masonry (See I/I Severity Value) 16
LB
LEAK
276 Leak - GW Infiltration (Slight <1 gpm) .50
IGW 2
LEAK
351 General Condition Photo 17GCP
409 10Tap - Break-in - Fair Condition -- 4" protrusion -- 18-inch VCP 18 &
19TB 2
LAT'L
409 Leak At/Around Lateral (See I/I Severity Value) 20 &
21LAL
LEAK
409 Leak - GW Infiltration (Slight <1 gpm) .75
IGW 2
LEAK
428 4Tap - Break-in - Structural Damage (slight-moder.) -- No protrusion -- 24-inch VCP
22 &
23TBS 2
LAT'L
428 Leak in/from Lateral -- Visible (See I/I Severity) -- Leaking joints
LLV
LEAK
428 Leak - GW Infiltration (Moderate 1-5 gpm) 1.0
IGW 3
LEAK
445 12Leak in Brickwork/Masonry (See I/I Severity Value) 24
LB
LEAK
445 Leak - GW Infiltration (Slight <1 gpm) .25
IGW 2
LEAK
455 10Tap - Break-in - Structural Damage (slight) -- 6" protrusion -- 12-inch VCP -- MD's at joint -- Possibly SNP 16G4-320C
25 &
26TBS 1
LAT'L
455 11Leak in Brickwork/Masonry (See I/I Severity Value) 27
LB
Page 2 of 16 From MH 16G4-319C To 16G4-284CA
GPM Photo No.
Defect
455 Leak - GW Infiltration (Seepage) .02
IGW 1
LEAK
455 General Condition Photo 28GCP
462 1Leak in Brickwork/Masonry (See I/I Severity Value)
LB
LEAK
462 Leak - GW Infiltration (Seepage) .02 29
IGW 1
LEAK
473 10-2Leak in Brickwork/Masonry (See I/I Severity Value) 30 &
31LB
LEAK
473 Leak - GW Infiltration (Moderate 1-5 gpm) 1.0
IGW 3
LEAK
477 2Leak in Brickwork/Masonry (See I/I Severity Value) 32
LB
LEAK
477 Leak - GW Infiltration (Slight <1 gpm) .25
IGW 2
LEAK
488 11Leak in Brickwork/Masonry (See I/I Severity Value) 33
LB
LEAK
488 Leak - GW Infiltration (Slight <1 gpm) .10
IGW 2
LEAK
491 3Leak in Brickwork/Masonry (See I/I Severity Value) 34
LB
LEAK
491 Leak - GW Infiltration (Slight <1 gpm) .75
IGW 2
LEAK
491-585 Bend to Left (slight-moderate -- 15-45 degrees)
BL 2
ALIGN
505 11Leak in Brickwork/Masonry (See I/I Severity Value) 35
LB
LEAK
505 Leak - GW Infiltration (Slight <1 gpm) .10
IGW 2
LEAK
508-509 11Leak in Brickwork/Masonry (See I/I Severity Value) 36
LB
LEAK
508-509 Leak - GW Infiltration (Slight <1 gpm) .50
IGW 2
LEAK
510 2Leak in Brickwork/Masonry (See I/I Severity Value) 37
LB
LEAK
510 Leak - GW Infiltration (Seepage) .02
IGW 1
LEAK
514 10Leak in Brickwork/Masonry (See I/I Severity Value) 38
LB
LEAK
514 Leak - GW Infiltration (Seepage) .02
IGW 1
LEAK
521 10Leak in Brickwork/Masonry (See I/I Severity Value) 39
LB
LEAK
521 Leak - GW Infiltration (Seepage) .02
IGW 1
LEAK
530 2Leak in Brickwork/Masonry (See I/I Severity Value) 40
LB
Page 3 of 16 From MH 16G4-319C To 16G4-284CA
GPM Photo No.
Defect
530 Leak - GW Infiltration (Seepage) .02
IGW 1
LEAK
557 4Tap - Capped - Structural Damage (moder.-severe) -- No protrusion -- 24-inch VCP -- Broken cap
41 &
42TCS 4
LAT'L
557 Leak in/from Lateral -- Visible (See I/I Severity) -- At broken cap 43
LLV
LEAK
557 Leak - GW Infiltration (Moderate 1-5 gpm) 1.25
IGW 3
LEAK
557 General Condition Photo 44GCP
562 11Leak in Brickwork/Masonry (See I/I Severity Value)
LB
LEAK
562 Leak - GW Infiltration (Seepage) .02
IGW 1
LEAK
570 10Leak in Brickwork/Masonry (See I/I Severity Value) 45
LB
LEAK
570 Leak - GW Infiltration (Seepage) .01
IGW 1
LEAK
587 1Leak in Brickwork/Masonry (See I/I Severity Value)
LB
LEAK
587 Leak - GW Infiltration (Seepage) .01
IGW 1
LEAK
611 2Leak At Joint (See I/I Severity Value) 46
LJ
LEAK
611 Leak - GW Infiltration (Seepage) .02
IGW 1
LEAK
621 8-4Leak in Brickwork/Masonry (See I/I Severity Value) 47
LB
LEAK
621 Leak - GW Infiltration (Slight <1 gpm) .50
IGW 2
LEAK
642 2Leak in Brickwork/Masonry (See I/I Severity Value) 48
LB
LEAK
642 Leak - GW Infiltration (Slight <1 gpm) .75
IGW 2
LEAK
647 1Leak in Brickwork/Masonry (See I/I Severity Value) 49
LB
LEAK
647 Leak - GW Infiltration (Moderate 1-5 gpm) 1.0
IGW 3
LEAK
655-657 10-2Leak in Brickwork/Masonry (See I/I Severity Value) 50
LB
LEAK
655-657 Leak - GW Infiltration (Moderate 1-5 gpm) 1.0
IGW 3
LEAK
667 1Leak in Brickwork/Masonry (See I/I Severity Value) 51
LB
LEAK
667 Leak - GW Infiltration (Moderate 1-5 gpm) 1.0
IGW 3
LEAK
667 General Condition Photo 52GCP
Page 4 of 16 From MH 16G4-319C To 16G4-284CA
GPM Photo No.
Defect
677 1-2Leak in Brickwork/Masonry (See I/I Severity Value) 53
LB
LEAK
677 Leak - GW Infiltration (Moderate 1-5 gpm) 1.0
IGW 3
LEAK
682 2Leak in Brickwork/Masonry (See I/I Severity Value)
LB
LEAK
682 Leak - GW Infiltration (Seepage) .02
IGW 1
LEAK
750 General Condition Photo 54GCP
786 11-1Leak in Brickwork/Masonry (See I/I Severity Value) 55
LB
LEAK
786 Leak - GW Infiltration (Slight <1 gpm) .25
IGW 2
LEAK
810 11Leak in Brickwork/Masonry (See I/I Severity Value) 56
LB
LEAK
810 Leak - GW Infiltration (Slight <1 gpm) .15
IGW 2
LEAK
836 4Tap - Capped - Structural Damage (moderate) -- No protrusion -- 24-inch VCP -- Full of MD's
57 &
58TCS 3
LAT'L
836 Leak in/from Lateral -- Visible (See I/I Severity) -- At cap 59
LLV
LEAK
836 Leak - GW Infiltration (Seepage) .02
IGW 1
LEAK
848 10Tap - Break-in - Fair Condition -- 2" protrusion -- 12-inch VCP -- MD's at joints
60 &
61TB 2
LAT'L
850 MH 16G4-284CA 62EDMH
Page 5 of 16 From MH 16G4-319C To 16G4-284CA
LS 16G4-319C to 16G4-284CA
Harlem Baden Hebert TV PHOTOS
FLow Measurement
0 l.f.PHOTO 1 MH 16G4-319C 2-848 l.f.PHOTO 2 Evidence of Leakage -- Slight -- MD's throughout pipe
53 l.f.PHOTO 3 Tap - Capped - Structural Damage (moderate) -- No protrusion -- 24-inch VCP
53 l.f.PHOTO 4 Leak in/from Lateral -- Visible (See I/I Severity) -- At cap
53 l.f.PHOTO 5 General Condition Photo 102 l.f.PHOTO 6 Leak in Brickwork/Masonry (See I/I Severity Value)
Page 6 of 16 From MH 16G4-319C To 16G4-284CA
106 l.f.PHOTO 7 Leak in Brickwork/Masonry (See I/I Severity
108 l.f.PHOTO 8 Leak in Brickwork/Masonry (See I/I Severity Value)
120 l.f.PHOTO 9 Moderate Corrosion/Erosion -- Exposed rebar
146-151 l.f.PHOTO 10 Leak in Brickwork/Masonry (See I/I Severity Value)
151 l.f.PHOTO 11 General Condition Photo 159 l.f.PHOTO 12 Leak in Brickwork/Masonry (See I/I Severity
Page 7 of 16 From MH 16G4-319C To 16G4-284CA
170 l.f.PHOTO 13 Tap - Break-in - Fair Condition -- 4" protrusion -- 15-inch VCP
170 l.f.PHOTO 14 Tap - Break-in - Fair Condition -- 4" protrusion -- 15-inch VCP
237 l.f.PHOTO 15 General Condition Photo 276 l.f.PHOTO 16 Leak in Brickwork/Masonry (See I/I Severity Value)
351 l.f.PHOTO 17 General Condition Photo 409 l.f.PHOTO 18 Tap - Break-in - Fair Condition -- 4" protrusion -- 18-inch VCP
Page 8 of 16 From MH 16G4-319C To 16G4-284CA
409 l.f.PHOTO 19 Tap - Break-in - Fair Condition -- 4" protrusion -- 18-inch VCP
409 l.f.PHOTO 20 Leak At/Around Lateral (See I/I Severity Value)
409 l.f.PHOTO 21 Leak At/Around Lateral (See I/I Severity Value)
428 l.f.PHOTO 22 Tap - Break-in - Structural Damage (slight-moder.) -- No protrusion -- 24-inch VCP
428 l.f.PHOTO 23 Tap - Break-in - Structural Damage (slight-moder.) -- No protrusion -- 24-inch VCP
445 l.f.PHOTO 24 Leak in Brickwork/Masonry (See I/I Severity
Page 9 of 16 From MH 16G4-319C To 16G4-284CA
455 l.f.PHOTO 25 Tap - Break-in - Structural Damage (slight) -- MD's at joint -- Possibly SNP
16G4-320C -- 6" protrusion -- 12-inch VCP
455 l.f.PHOTO 26 Tap - Break-in - Structural Damage (slight) -- MD's at joint -- Possibly SNP
16G4-320C -- 6" protrusion -- 12-inch VCP
455 l.f.PHOTO 27 Leak in Brickwork/Masonry (See I/I Severity Value)
455 l.f.PHOTO 28 General Condition Photo
462 l.f.PHOTO 29 Leak - GW Infiltration (Seepage) 473 l.f.PHOTO 30 Leak in Brickwork/Masonry (See I/I Severity
Page 10 of 16 From MH 16G4-319C To 16G4-284CA
473 l.f.PHOTO 31 Leak in Brickwork/Masonry (See I/I Severity
477 l.f.PHOTO 32 Leak in Brickwork/Masonry (See I/I Severity Value)
488 l.f.PHOTO 33 Leak in Brickwork/Masonry (See I/I Severity Value)
491 l.f.PHOTO 34 Leak in Brickwork/Masonry (See I/I Severity Value)
505 l.f.PHOTO 35 Leak in Brickwork/Masonry (See I/I Severity Value)
508-509 l.f.PHOTO 36 Leak in Brickwork/Masonry (See I/I Severity
Page 11 of 16 From MH 16G4-319C To 16G4-284CA
510 l.f.PHOTO 37 Leak in Brickwork/Masonry (See I/I Severity
514 l.f.PHOTO 38 Leak in Brickwork/Masonry (See I/I Severity Value)
521 l.f.PHOTO 39 Leak in Brickwork/Masonry (See I/I Severity Value)
530 l.f.PHOTO 40 Leak in Brickwork/Masonry (See I/I Severity Value)
557 l.f.PHOTO 41 Tap - Capped - Structural Damage (moder.-severe) -- Broken cap -- No protrusion -- 24-inch VCP
557 l.f.PHOTO 42 Tap - Capped - Structural Damage (moder.-severe) -- Broken cap -- No protrusion -- 24-inch VCP
Page 12 of 16 From MH 16G4-319C To 16G4-284CA
557 l.f.PHOTO 43 Leak in/from Lateral -- Visible (See I/I Severity) -- At broken cap
557 l.f.PHOTO 44 General Condition Photo
570 l.f.PHOTO 45 Leak in Brickwork/Masonry (See I/I Severity Value)
611 l.f.PHOTO 46 Leak At Joint (See I/I Severity Value)
621 l.f.PHOTO 47 Leak in Brickwork/Masonry (See I/I Severity Value)
642 l.f.PHOTO 48 Leak in Brickwork/Masonry (See I/I Severity
Page 13 of 16 From MH 16G4-319C To 16G4-284CA
647 l.f.PHOTO 49 Leak in Brickwork/Masonry (See I/I Severity
655-657 l.f.PHOTO 50 Leak in Brickwork/Masonry (See I/I Severity Value)
667 l.f.PHOTO 51 Leak in Brickwork/Masonry (See I/I Severity Value)
667 l.f.PHOTO 52 General Condition Photo
677 l.f.PHOTO 53 Leak in Brickwork/Masonry (See I/I Severity Value)
750 l.f.PHOTO 54 General Condition Photo
Page 14 of 16 From MH 16G4-319C To 16G4-284CA
786 l.f.PHOTO 55 Leak in Brickwork/Masonry (See I/I Severity
810 l.f.PHOTO 56 Leak in Brickwork/Masonry (See I/I Severity Value)
836 l.f.PHOTO 57 Tap - Capped - Structural Damage (moderate) -- Full of MD's -- No protrusion -- 24-inch VCP
836 l.f.PHOTO 58 Tap - Capped - Structural Damage (moderate) -- Full of MD's -- No protrusion -- 24-inch VCP
836 l.f.PHOTO 59 Leak in/from Lateral -- Visible (See I/I Severity) -- At cap
848 l.f.PHOTO 60 Tap - Break-in - Fair Condition -- MD's at joints -- 2" protrusion -- 12-inch VCP
Page 15 of 16 From MH 16G4-319C To 16G4-284CA
848 l.f.PHOTO 61 Tap - Break-in - Fair Condition -- MD's at joints -- 2" protrusion -- 12-inch VCP
850 l.f.PHOTO 62 MH 16G4-284CA
Page 16 of 16 From MH 16G4-319C To 16G4-284CA