INTERNAL INSPECTION LOG
FLow Measurement
Date: 2/12/2010
Technician: ADS
ADS Environmental Services
16H3-006C 16H3-007C
Downstream Line Depth NA
Sewer Plug Locations
None
Dyed-Water Flood Sketch None
Upstream Line Depth NA
ADDITIONAL INFORMATION
Type Of Sewer Combination
Harlem Baden Hebert
LOCATION: Esmt off Idadale Avenue
PROJECT:
Total Line Length 89
Type Of Pipe RCB
Joint Spacing 0
Pipe Diameter 60x60
Avg. Depth
Uncapped SC's
Comments:
TAPE NO. 17
Start Counter 03121
End Counter 03631 ft.
ft. in.
in.
l.f.
l.f.
in.
ft.TV Line Length 89 l.f.
TV against the direction of flow
Time: 1:05 PM
Precleaning N
Upstream Structure Downstream Structure
End Inspection Start Inspection
Capped SC's
Distance Defect Description Clock Ref.
GPM Photo No.
Defect
0 MH 16H3-007C 1BDMH
2-87 Less Than 1/8-Pipe Water Depth W 1
ALIGN
2-87 Sludge/Sand & Grit (<10% dia.)
SGR 1
DEBRIS
6-87 Minor to Light Corrosion/Erosion
SR 1
DETER
6-87 Evidence of Leakage -- Slight to Moderate -- MD's 2
EL 2
LEAK
52 General Condition Photo 3GCP
87 1Tap - Break-in - Fair to Good Condition -- No protrusion -- 10-inch VCP
TB 1
LAT'L
89 MH 16H3-006C 5EUMH
Page 1 of 2 From MH 16H3-006C To 16H3-007C
LS 16H3-006C to 16H3-007C
Harlem Baden Hebert TV PHOTOS
FLow Measurement TV against the direction of flow
0 l.f.PHOTO 1 MH 16H3-007C 6-87 l.f.PHOTO 2 Evidence of Leakage -- Slight to Moderate -- MD's
52 l.f.PHOTO 3 General Condition Photo 87 l.f.PHOTO 4 Tap - Break-in - Fair to Good Condition -- No protrusion -- 10-inch VCP
89 l.f.PHOTO 5 MH 16H3-006C
Page 2 of 2 From MH 16H3-006C To 16H3-007C