Text version
INTERNAL INSPECTION LOG
FLow Measurement
Date: 5/4/2010
Technician: ADS
ADS Environmental Services
16G4-293C 16G3-232C
Downstream Line Depth NA
Sewer Plug Locations
None
Dyed-Water Flood Sketch None
Upstream Line Depth NA
ADDITIONAL INFORMATION
Type Of Sewer Combined
Harlem Baden Hebert
LOCATION: Easement off Blackstone Ave.
PROJECT:
Total Line Length 1057
Type Of Pipe MIX
Joint Spacing 30
Pipe Diameter 144x122
Avg. Depth
Uncapped SC's
Comments:
TAPE NO. A
Start Counter 00000
End Counter 11720 ft.
ft. in.
in.
l.f.
l.f.
in.
ft.TV Line Length 1057 l.f.
TV against the direction of flow
Time: 11:00 AM
Precleaning N
Upstream Structure Downstream Structure
End Inspection Start Inspection
Capped SC's
Distance Defect Description Clock Ref.
GPM Photo No.
Defect
0 MH 16G3-232C 1BDMH
2-1055 Less Than 1/8-Pipe Water Depth W 1
ALIGN
2-1055 Sludge/Sand & Grit (<10% dia.)
SGR 1
DEBRIS
2-1055 Minor to Light Corrosion/Erosion
SR 1
DETER
2-1055 Evidence of Leakage -- Slight -- MD's at most joints
EL 1
LEAK
10-15 10Moderate to Severe Corrosion/Erosion 2
SR 4
DETER
19 2Special Structure - Node Point/Junction 3STRJ
51 12Moderate Corrosion/Erosion -- Exposed rebar 4
SR 3
DETER
73 11Leak At Joint (See I/I Severity Value) 5
LJ
LEAK
73 Leak - GW Infiltration (Slight <1 gpm) .25
IGW 2
LEAK
94 12Leak At Joint (See I/I Severity Value) 6
LJ
LEAK
94 Leak - GW Infiltration (Slight <1 gpm) .20
IGW 2
LEAK
Page 1 of 10 From MH 16G4-293C To 16G3-232C
Distance Defect Description Clock Ref.
GPM Photo No.
Defect
144 General Condition Photo 7GCP
147 8Tap - Break-in - Structural Damage (moder.-severe) -- 31-inch VCP -- Full of debris
TBS 4
LAT'L
148 8Tap - Break-in - Structural Damage (severe) -- No protrusion -- 31-inch VCP -- Collapsed
TBS 5
LAT'L
148 Leak in/from Lateral -- Visible (See I/I Severity)
LLV
LEAK
148 Leak - GW Infiltration (Moderate 1-5 gpm) 1.25
IGW 3
LEAK
250 General Condition Photo 10GCP
263 3Tap - Break-in - Fair to Good Condition -- No protrusion -- 41-inch VCP -- Manhole in view
TB 1
LAT'L
348 General Condition Photo 12GCP
362 2Tap - Break-in - Fair Condition -- 20" protrusion -- 12-inch PVC 13
TB 2
LAT'L
378 11Leak At Joint (See I/I Severity Value) 14
LJ
LEAK
378 Leak - GW Infiltration (Moderate 1-5 gpm) 1.5
IGW 3
LEAK
386 8Special Structure - Node Point/Junction -- Called SNP 16G4-260C 15STRJ
418 11Leak At Joint (See I/I Severity Value) 16
LJ
LEAK
418 Leak - GW Infiltration (Moderate 1-5 gpm) 1.0
IGW 3
LEAK
452 General Condition Photo 17GCP
546 General Condition Photo 18GCP
560 11Tap - Break-in - Structural Damage (slight) -- No protrusion -- 15-inch VCP -- Offset joints
TBS 1
LAT'L
575 8Leak At Joint (See I/I Severity Value) 20
LJ
LEAK
575 Leak - GW Infiltration (Moderate 1-5 gpm) 1.25
IGW 3
LEAK
648 General Condition Photo 21GCP
690 9Leak in Brickwork/Masonry (See I/I Severity Value) 22
LB
LEAK
690 Leak - GW Infiltration (Moderate 1-5 gpm) 1.5
IGW 3
LEAK
703 7Leak in Brickwork/Masonry (See I/I Severity Value) 23
LB
LEAK
703 Leak - GW Infiltration (Moderate 1-5 gpm) 1.0
IGW 3
LEAK
Page 2 of 10 From MH 16G4-293C To 16G3-232C
Distance Defect Description Clock Ref.
GPM Photo No.
Defect
707 7Leak in Brickwork/Masonry (See I/I Severity Value) 24
LB
LEAK
707 Leak - GW Infiltration (Moderate 1-5 gpm) 2.5
IGW 3
LEAK
712 2Tap - Capped - Fair Condition -- 27-inch VCP 25
TC 2
LAT'L
715 7-5Leak At Joint (See I/I Severity Value) 26
LJ
LEAK
715 Leak - GW Infiltration (Moderate 1-5 gpm) 4.0
IGW 3
LEAK
723 11Leak in Brickwork/Masonry (See I/I Severity Value) 27
LB
LEAK
723 Leak - GW Infiltration (Moderate 1-5 gpm) 1.0
IGW 3
LEAK
729 11Leak in Brickwork/Masonry (See I/I Severity Value) 28
LB
LEAK
729 Leak - GW Infiltration (Moderate 1-5 gpm) 1.5
IGW 3
LEAK
729-730 12Moderate Corrosion/Erosion 29
SR 3
DETER
741 7-5Leak At Joint (See I/I Severity Value) 30
LJ
LEAK
741 Leak - GW Infiltration (Moderate 1-5 gpm) 1.0
IGW 3
LEAK
795 Pipe Material or Liner Change -- RCB 31 &
PSHP
842 8Leak in Brickwork/Masonry (See I/I Severity Value) 33 &
34LB
LEAK
842 Leak - GW Infiltration (Moderate 1-5 gpm) 1.0
IGW 3
LEAK
866 3Special Structure - Node Point/Junction 35STRJ
866 Leak At/Around Lateral (See I/I Severity Value)
LAL
LEAK
866 Leak - GW Infiltration (Moderate 1-5 gpm) 5.0
IGW 3
LEAK
970 Man-made or Mfg'd. Debris (<10% dia.) -- Manhole cover 36
MFG 1
OBSTR
1017 3Special Structure - Node Point/Junction -- Called SNP 16G4-292C 37STRJ
1057 MH 16G4-293C 38EUMH
Page 3 of 10 From MH 16G4-293C To 16G3-232C
LS 16G4-293C to 16G3-232C
Harlem Baden Hebert TV PHOTOS
FLow Measurement TV against the direction of flow
0 l.f.PHOTO 1 MH 16G3-232C 10-15 l.f.PHOTO 2 Moderate to Severe Corrosion/Erosion
19 l.f.PHOTO 3 Special Structure - Node Point/Junction 51 l.f.PHOTO 4 Moderate Corrosion/Erosion -- Exposed rebar
73 l.f.PHOTO 5 Leak At Joint (See I/I Severity Value) 94 l.f.PHOTO 6 Leak At Joint (See I/I Severity Value)
Page 4 of 10 From MH 16G4-293C To 16G3-232C
144 l.f.PHOTO 7 General Condition Photo 147 l.f.PHOTO 8 Tap - Break-in - Structural Damage (moder.-severe) -- Full of debris -- 31-inch VCP
148 l.f.PHOTO 9 Tap - Break-in - Structural Damage (severe) -- Collapsed -- No protrusion -- 31-inch VCP
250 l.f.PHOTO 10 General Condition Photo
263 l.f.PHOTO 11 Tap - Break-in - Fair to Good Condition -- Manhole in view -- No protrusion -- 41-inch
VCP
348 l.f.PHOTO 12 General Condition Photo
Page 5 of 10 From MH 16G4-293C To 16G3-232C
362 l.f.PHOTO 13 Tap - Break-in - Fair Condition -- 20" protrusion -- 12-inch PVC
378 l.f.PHOTO 14 Leak At Joint (See I/I Severity Value)
386 l.f.PHOTO 15 Special Structure - Node Point/Junction -- Called SNP 16G4-260C
418 l.f.PHOTO 16 Leak At Joint (See I/I Severity Value)
452 l.f.PHOTO 17 General Condition Photo 546 l.f.PHOTO 18 General Condition Photo
Page 6 of 10 From MH 16G4-293C To 16G3-232C
560 l.f.PHOTO 19 Tap - Break-in - Structural Damage (slight) -- Offset joints -- No protrusion -- 15-inch VCP
575 l.f.PHOTO 20 Leak At Joint (See I/I Severity Value)
648 l.f.PHOTO 21 General Condition Photo 690 l.f.PHOTO 22 Leak in Brickwork/Masonry (See I/I Severity Value)
703 l.f.PHOTO 23 Leak in Brickwork/Masonry (See I/I Severity Value)
707 l.f.PHOTO 24 Leak in Brickwork/Masonry (See I/I Severity Value)
Page 7 of 10 From MH 16G4-293C To 16G3-232C
712 l.f.PHOTO 25 Tap - Capped - Fair Condition -- 27-inch
VCP
715 l.f.PHOTO 26 Leak At Joint (See I/I Severity Value)
723 l.f.PHOTO 27 Leak in Brickwork/Masonry (See I/I Severity Value)
729 l.f.PHOTO 28 Leak in Brickwork/Masonry (See I/I Severity Value)
729-730 l.f.PHOTO 29 Moderate Corrosion/Erosion 741 l.f.PHOTO 30 Leak At Joint (See I/I Severity Value)
Page 8 of 10 From MH 16G4-293C To 16G3-232C
795 l.f.PHOTO 31 Pipe Material or Liner Change -- RCB 795 l.f.PHOTO 32 Pipe Material or Liner Change -- RCB
842 l.f.PHOTO 33 Leak in Brickwork/Masonry (See I/I Severity Value)
842 l.f.PHOTO 34 Leak in Brickwork/Masonry (See I/I Severity Value)
866 l.f.PHOTO 35 Special Structure - Node Point/Junction 970 l.f.PHOTO 36 Man-made or Mfg'd. Debris (<10% dia.) -- Manhole cover
Page 9 of 10 From MH 16G4-293C To 16G3-232C
1017 l.f.PHOTO 37 Special Structure - Node Point/Junction -- Called SNP 16G4-292C
1057 l.f.PHOTO 38 MH 16G4-293C
Page 10 of 10 From MH 16G4-293C To 16G3-232C
File details come from the government source that posted it.