TE_15_PaintBoothLog.docx

DOCX document 30 KB Posted

Attached to
DRAFT Solicitation for Base Operations and Maintenance Services, Fort Huachuca, Arizona 20231115
Solicitation number
W9124A23R0005
Issued by

About this file

This document contains a technical exhibit outlining requirements for maintaining a paint booth log at Fort Huachuca, Arizona. The log includes details of each painting project such as the job number, type of equipment painted, paint or solvent used with corresponding MSDS number, amount used, emission controls, filter status, and operator information. Painting operations must be conducted in an enclosed area with at least 96% overspray containment and non-photochemically reactive solvents. The log aims to document painting activities for safety and regulatory compliance.

A related forthcoming solicitation from the Department of the Army will seek base operations and maintenance services at Fort Huachuca, including maintenance of the paint booth and adherence to the log requirements.

View the file

Other files

File Type Posted
Att 11 Residential CWR AZ20230004.pdf PDF
TE_26_PropaneTanks.docx DOCX document
Annex S - Portable Latrine Services (504).docx DOCX document
Annex M - Pest Management (510).docx DOCX document
Att 9 Pricing Matrix LCAT 10-25-23.xlsx XLSX spreadsheet
Att 14 - Site Access Information.docx DOCX document
Att 8 Pricing Matrix - Worksheet 10-27-2023.xlsx XLSX spreadsheet
Annex P - Facilities Engineering Services Management (400).docx DOCX document
TE_53_FHMoldIdentificationandRemediationSOP.pdf PDF
TE_48_WorkloadIW37NA001A004CombinedData(Master).xlsx XLSX spreadsheet
Att 12 SCA WD 2015-5719 Rev 20.pdf PDF
TE_10_AdverseWeatherPlan.docx DOCX document
TE_31_HVACMaintenanceandReports(ACVent).docx DOCX document
TE_12_Asbestos.docx DOCX document
Att 17 Quality Assurance Surveillance Plan 2023.docx DOCX document
Annex L - Wastewater Services (503).docx DOCX document
TE_22_EmergencyElevatorService.docx DOCX document
Att 15 - DD Form 254.pdf PDF
TE_46_WorkloadNon-recurringIJO2019-2023.xlsx XLSX spreadsheet
TE_37_FHDiggingExcavationPermit.pdf PDF
TE_28_WaterGasMeters.docx DOCX document
TE_21_GroundsSafetyLog.docx DOCX document
TE_41_DAForm4283.pdf PDF
TE_45_PortableLatrineList.xlsx XLSX spreadsheet
Annex J - Maintenance - Surfaced and Unsurfaced Areas (420) .docx DOCX document
TE_25_NaturalGasEmergency.docx DOCX document
TE_23_FireAlarms.docx DOCX document
Att 5 Past Performance Reference List (PART A).docx DOCX document
Att 7 Past Performance Questionnaire (PPQ).docx DOCX document
TE_30_FireSprinkler.docx DOCX document
Annex T - Environmental ENRD (505).docx DOCX document
TE_18_90DayPM.docx DOCX document
TE_14_GreaseTrap.docx DOCX document
TE_17_BarracksLocks.docx DOCX document
TE_06_WOPriorityCalcTable.docx DOCX document
Annex E - Solid Waste Management (403).docx DOCX document
TE_04_DirectivesandPublications.docx DOCX document
Annex H - Facilities Maintenance (411).docx DOCX document
Att 3 - Staffing Matrix.xlsx XLSX spreadsheet
Att 11 Heavy CWR AZ20230037.pdf PDF
Annex G - Snow_Ice_and Sand Removal (408).docx DOCX document
TE_05_DeliverablesList.docx DOCX document
TE_55_Integrated Wildland and Fire Management Plan.pdf PDF
Annex F - Maintenance - Grounds (404).docx DOCX document
Att 10 CBA and Addendum 1 -17.pdf PDF
TE_57 Project Stock Movements.xlsx XLSX spreadsheet
TE_34_GovtFurnishedBldgs.docx DOCX document
TE_07_NTP.docx DOCX document
TE_01_TechnicalExhibitList.docx DOCX document
Att 13 Site Visit Registration Form.docx DOCX document
Show 40 more

Latest 50 of 90 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Base Operations (BASOPS) Performance Work Statement Technical Exhibit 15 – Paint Booth Log

Paint Booth Activity Log

Location Name
O&M Contractor Paint Booth
Building Number
22524

Emission Control Measure Utilized

Dry Filters

Source POC

Date of Project

Job/Project/ Work Order Number

Magnehelic Gage Reading = < ½ in. water

Product Used (Paint or Solvent)

Product MSDS Number Amount of Product Used Type of Equipment or Media Painted

Duration of Project

Operator

Filter Replacement Log and Additional Information (Reference the project, where applicable):

Non‐tactical application unless otherwise noted. Replace filters if magnehelic gage reads ½ in. of water or greater.

→ Complete this log each time a spray painting project is conducted. ***All fields are required*** → Notify Environmental and Natural Resources Division (ENRD) regarding any process changes (includes changes in spray gun equipment, new paints or solvents, proposed control measure changes, etc.). The use of photochemically reactive solvents is prohibited.

→ All painting operations must be conducted in an enclosed area equipped with controls containing no less than 96% of the overspray.

→ Follow all manufacturer instructions regarding filter installation and maintenance.

File details come from the government source that posted it. Updated .