P102_R1_AD2___PLUMBING_RENOVATION_PLAN__PHASE.pdf

PDF 833 KB Posted

Attached to
RFP for Ridgeland High School Renovations
Solicitation number
PE-55462-NONST-2026-000000017
Issued by
Wilcox County, Georgia

About this file

This is a plumbing renovation plan for Ridgeland High School prepared by Southern A&E, LLC for Walker County Schools, located in Lafayette, Georgia. The project encompasses Phase 1 renovations to the football and baseball fieldhouse facilities and includes detailed plumbing floor plans and demolition plans for both upper and lower levels. The scope of work involves replacement of plumbing fixtures including water closets (WC-2), lavatories (LAV-1), showers (SH-3), and urinals (UR-2) with ADA-compliant models, along with associated flush valves, faucets, and trim components. Work also includes removal of existing plumbing fixtures and piping back to main lines with caps, replacement of floor drain grates with extension kits as necessary, and field verification of exact sizes and locations. The document was issued for construction on October 31, 2025, and notes that certain scope of work will only be performed if alternates are taken.

The document does not contain information regarding pricing terms, set asides, contract incumbents, response dates, due dates, or funding sources. The plan is intended as a technical reference document showing the locations and specifications of plumbing work across multiple rooms including lecture rooms, mechanical spaces, toilet facilities, locker rooms, offices, and storage areas. The project is managed under the Southern A&E, LLC engineering firm (License No. PEF003374, expiration June 30, 2026) and is part of a larger bidding package designated BP-1 with project number 01-920-045.

View the file

Other files

File Type Posted
P203_R1_AD2___PLUMBING_ENLARGED_PLANS.pdf PDF
E003_R2_AD2___MECHANICAL_EQUIPMENT_CONNECTION.pdf PDF
M113_R2_AD2_MECHANICAL_DEMOLITION_PLAN__WING_.pdf PDF
M126_R2_AD2_MECHANICAL_RENOVATION_PLAN__WING_.pdf PDF
E123_R2_AD2___WING_G__ELECTRICAL_DEMOLITION_P.pdf PDF
Advertisement _ RHS Renovations.pdf PDF
E135_R2_AD2___WING_F_G_K__ROOF__POWER_PLAN.pdf PDF
P106_R1_AD2___PLUMBING_ROOF_PLAN__ALTERNATE.pdf PDF
E117_R1_AD2___WING_E__POWER_PLAN.pdf PDF
ADDENDUM_2__COMPLETE.pdf PDF
E103_R2_AD2___WING_A__POWER_PLAN.pdf PDF
M128_R2_AD2_MECHANICAL_RENOVATION_PLAN__WING_.pdf PDF
M112_R2_AD2_MECHANICAL_DEMOLITION_PLAN__WING_.pdf PDF
M130_R2_AD2_MECHANICAL_RENOVATION_PLAN__WING_.pdf PDF
P201_R1_AD2___PLUMBING_ENLARGED_PLANS.pdf PDF
M115_R2_AD2_MECHANICAL_DEMOLITION_PLAN__WING_.pdf PDF
M127_R2_AD2_MECHANICAL_RENOVATION_PLAN__WING_.pdf PDF
M125_R2_AD2_MECHANICAL_RENOVATION_PLAN__WING_.pdf PDF
E129_R2_AD2___MEZZ_LEVEL__WING_G__POWER_PLAN.pdf PDF
M129_R2_AD2_MECHANICAL_RENOVATION_PLAN__WING_.pdf PDF
M602_R2_AD2_MECHANICAL_EQUIPMENT_SCHEDULES.pdf PDF
M110_R2_AD2_MECHANICAL_DEMOLITION_PLAN__WING_.pdf PDF
M601_R2_AD2_MECHANICAL_EQUIPMENT_SCHEDULES.pdf PDF
E125_R2_AD2___WING_G__POWER_PLAN.pdf PDF
P202_R1_AD2___PLUMBING_ENLARGED_PLANS.pdf PDF
P103_R1_AD2___PLUMBING_RENOVATION_FLOOR_PLAN_.pdf PDF
M503_R2_AD2_MECHANICAL_EQUIPMENT_DETAILS.pdf PDF
Project Award Recommendation _ RHS HVAC.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

DN

P203

P2 P2

P6

P6

P8

WC-1

SH-3

LAV-2

LAV-2

SH-3

WC-1

D27D27

P8

D21

D21

D21

D21

D21

D21

D21

D21

D29

D29 D29

D29

NOTE: SCOPE OF WORK WILL ONLY BE PERFORMED IF ALTERNATE IS TAKEN.

P202

P2

P6

P8

D27

WC-2

LAV-1

SH-3

NOTE: SCOPE OF WORK WILL ONLY BE PERFORMED IF ALTERNATE IS TAKEN.

P2

P2

P4

P6 P6

WC-2

WC-2

LAV-1

UR-2

LAV-1

LECTURE ROOM

MECH.

STOR.

BOYS TOILET

GIRLS TOILET

GIRLS TOILET

VEST.

BOYS LOCKER ROOM

CONCESSIONS

OFFICE

OFFICE

REFEREE LOUNGE

STAIR

VEST.

BOYS TOILET

STOR.

STOR.

PASSAGE

STOR.

TOILET

P202

2 3

P202

WC-2

LAV-1

SH-3

NOTE: SCOPE OF WORK WILL ONLY BE PERFORMED IF ALTERNATE IS TAKEN.

P2

P6

P8

D27

SCALE: = 1'-0"

DRAWING NUMBER

REVISIONS

COPYRIGHT 2025 BY SOUTHERN A&E, LLC. ALL RIGHTS RESERVED.

THIS DOCUMENT IS THE PROPERTY OF SOUTHERN A&E, LLC AND SHALL

NOT BE COPIED OR REPRODUCED IN WHOLE OR IN PART WITHOUT

EXPRESSED WRITTEN CONSENT FROM SOUTHERN A&E, LLC.

10-31-2025

BID PACKAGE BP-1

SA&E PROJECT NUMBER

ORIGINAL SHEET SIZE: ARCH E1 (30" X 42")

A

TRUE

NORTH

0 8 168

1/8"

2" GRIDS 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

B

C

D

E

F

G

H

I

J

K

L

M

N

KEYPLAN

RIDGELAND HIGH SCHOOL

RENOVATIONS TO:

WALKER COUNTY SCHOOLS

301 N CHEROKEE ST, LAFAYETTE, GA 30728

2478 HAPPY VALLEY RD, ROSSVILLE, GA 30741

746-0190

01-920-045

ISSUED FOR CONSTRUCTION

STATE BOARD OF REGISTRATION

FOR PROFESSIONAL ENGINEERS AND

LAND SURVEYORS

SOUTHERN A & E, LLC

ENGINEER FIRM

LICENSE NO: PEF003374

EXP. DATE - 06/30/2026

B

A

C

D E

F

G

H

J

K

P102

PLUMBING RENOVATION PLAN - PHASE 1 -

FOOTBALL AND BASEBALL FEILDHOUSE

KEYNOTE SCHEDULE

# KEYNOTE DESCRIPTION

D21 REMOVE PLUMBING FIXTURE AND TRIM. REMOVE ALL ASSOCIATED CW AND HW PIPE BACK TO

MAIN AND CAP. REMOVE CW AND HW PIPING IN A WAY THAT THERE IS NO MORE THAN 1 FOOT

OF DEAD LEG PIPING. FIELD VERIFY EXACT SIZE AND LOCATION OF EXISTING.

D27 REPLACE EXISTING SHOWER WITH NEW SH-3.

D29 EXISTING FLOOR DRAIN TO REMAIN. DISCONNECT ASSOCIATED SANITARY WASTE AND TRAP

PRIMER LINE AND CAP AT MAIN. FIELD VERIFY EXACT SIZE AND LOCATION.

P2 REPLACE EXISTING ADA WATER CLOSET AND ASSOCIATED FLUSH VALVE WITH NEW WC-2

AND WFV-1. PROVIDE NEW FLANGE, WAX BOWL RING, TOILET FLANGE EXTENSION KIT (FOAM

GASKET, SPACER, FLANGE EXTENDER, MECHANICAL FASTENERS).

P4 REPLACE EXISTING ADA URINAL AND ASSOCIATED FLUSH VALVE WITH NEW UR-2 AND UFV-1

AND TRAP ADAPTER FITTING.

P6 REPLACE EXISTING ADA LAVATORY AND ASSOCIATED FAUCET WITH NEW LAV-1 AND LFT-1.

FURNISH AND INSTALL NEW TRAP, DOUBLE OUTLET STOP, TRAP ADAPTER FITTING, TRAP

GUARD, AND SUPPLY LINES. FIELD VERIFY EXACT LOCATION AND MOUNTING HEIGHT OF

EXISTING.

P8 REPLACE EXISTING FLOOR DRAIN GRATE WITH NEW. PROVIDE PROVIDE FLOOR DRAIN

EXTENSION KIT AS NECESSARY - COORDINATE WITH NEW FLOORING. FIELD VERIFY EXACT

LOCATION AND EXTENSION HEIGHT. IF FLOOR DRAIN GRATE CANNOT BE REPLACED,

THOUROUGHLY CLEAN GRATE AND REINSTALL.

1/8" = 1'-0"P102

1 ALTERNATE: PLUMBING FLOOR PLAN - PHASE 1 - FOOTBALL FIELDHOUSE - UPPER LEVEL

1/8" = 1'-0"P102

2 ALTERNATE: PLUMBING DEMOLITION PLAN - PHASE 1 - FOOTBALL FIELDHOUSE - LOWER LEVEL

1/8" = 1'-0"P102

4 PLUMBING FLOOR PLAN - PHASE 1 - BASEBALL FIELDHOUSE

1/8" = 1'-0"P102

3 ALTERNATE: PLUMBING DEMOLITION PLAN - PHASE 1 - FOOTBALL FIELDHOUSE - LOWER LEVEL

# Doc # Date