M126_R2_AD2_MECHANICAL_RENOVATION_PLAN__WING_.pdf
PDF 249 KB Posted
- Attached to
- RFP for Ridgeland High School Renovations
- Solicitation number
- PE-55462-NONST-2026-000000017
- Issued by
- Wilcox County, Georgia
About this file
This is a mechanical renovation plan drawing for Ridgeland High School prepared by Southern A&E, LLC, an engineering firm licensed by the State Board of Registration for Professional Engineers and Land Surveyors (License No. PEF003374, expiration 06/30/2026). The project is for Walker County Schools, located at 301 N Cherokee Street, Lafayette, Georgia 30728, with the school site at 2478 Happy Valley Road, Rossville, Georgia 30741. The mechanical renovation plan addresses Wing F roof systems and includes detailed specifications for HVAC components, refrigerant line routing through existing pipe chases, and labeling requirements per specification section 230553. The drawing is part of Bid Package BP-1 (SA&E Project Number 01-920-045) and was issued for construction on 10-31-2025 at a scale of 1/8" = 1'-0" on an ARCH E1 sheet size (30" x 42"). The document references continuation details in drawings M124 and M129, with keynotes indicating that existing gravity intake/relief hoods and other specified components are to remain in place.
The drawing includes addendum information, with Addendum 1 (AD1) issued on 11-13-2025 and Addendum 2 (AD2) issued on 11-21-2025, indicating ongoing modifications to the project scope. The document is copyright-protected by Southern A&E, LLC and cannot be reproduced without expressed written consent. No specific pricing, contract terms, award dates, or bidder meeting information is contained within this mechanical plan document, as it functions solely as a technical specification and design drawing for the renovation work.
View the file
Other files
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MHP
F
CU
CU
CU
CU
CU
F
CU
CU
CU
CU
F
D24
D24
D24
D10
D10
M503
M502
SEE
DETAIL
TYP
SEE
DETAIL
TYP
M503
SEE
DETAIL
F O
R C
O N
T
IN
U A
T
IO
N
R E
F E
R T
O
M
FOR CONTINUATION REFER TO: 1/ M129
D10
M4
M4
M4
M4
M4
M4
DRAWING NUMBER
REVISIONS
COPYRIGHT 2025 BY SOUTHERN A&E, LLC. ALL RIGHTS RESERVED.
THIS DOCUMENT IS THE PROPERTY OF SOUTHERN A&E, LLC AND SHALL
NOT BE COPIED OR REPRODUCED IN WHOLE OR IN PART WITHOUT
EXPRESSED WRITTEN CONSENT FROM SOUTHERN A&E, LLC.
10-31-2025
BID PACKAGE BP-1
SA&E PROJECT NUMBER
ORIGINAL SHEET SIZE: ARCH E1 (30" X 42")
A
TRUE
NORTH
2" GRIDS 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
B
C
D
E
F
G
H
I
J
K
L
M
N
KEYPLAN
RIDGELAND HIGH SCHOOL
RENOVATIONS TO:
WALKER COUNTY SCHOOLS
301 N CHEROKEE ST, LAFAYETTE, GA 30728
2478 HAPPY VALLEY RD, ROSSVILLE, GA 30741
746-0190
01-920-045
ISSUED FOR CONSTRUCTION
STATE BOARD OF REGISTRATION
FOR PROFESSIONAL ENGINEERS AND
LAND SURVEYORS
SOUTHERN A & E, LLC
ENGINEER FIRM
LICENSE NO: PEF003374
EXP. DATE - 06/30/2026
B
A
C
D E
F
G
H
J
K
M126
MECHANICAL RENOVATION PLAN - WING F
ROOF
SCALE: = 1'-0"
0 8 168
1/8"
1/8" = 1'-0"M126
1 MECHANICAL RENOVATION PLAN - WING F ROOF
KEYNOTE SCHEDULE
# KEYNOTE DESCRIPTION
D10 EXISTING GRAVITY INTAKE/RELIFE HOOD TO REMAIN.
D24 EXSITING TO REMAIN.
M4 ROUTE REFRIGERANT LINES NEATLY THRU EXISTING PIPE CHASE HOUSING TO THE
RESPECTIVE UNIT. LABEL REFRIGERANT LINES WITH THE ASSOCIATED INDOOR UNIT
DESIGNATION. REFER TO SPECIFICATION SECTION 230553 FOR LABELING REQUIREMENTS.
# Doc # Date
1 AD1 11-13-2025
2 AD2 11-21-2025
File details come from the government source that posted it. Updated .