About this file

This is a mechanical demolition plan for the Ridgeland High School Renovations project, issued by Southern A&E, LLC for Walker County Schools in Georgia. The plan details the removal and preparation of existing mechanical systems in Wing G Mezzanine, including exhaust fans, ductwork, condensing units, heat pumps, gas furnaces, air handlers, makeup air units, damper actuators, and water-source heat pump piping. Specific keynotes designate which components are to be removed, which are to remain, and which require modification or preparation for new installation. The drawing is dated October 31, 2025, and issued for construction as part of Bid Package BP-1. The mandatory pre-proposal meeting for general contractors is scheduled for Thursday, November 20, 2025, at 9:00 AM at the project site located at 2478 Happy Valley Road, Rossville, Georgia 30741. Sealed proposals from general contractors must be submitted to the Walker County Board of Education's Facilities and Operations Department at 298 Culberson Avenue, LaFayette, Georgia 30728 by 2:00 PM on Thursday, December 11, 2025. Failure to attend the mandatory pre-proposal meeting will result in rejection of any submitted proposals without consideration.

No pricing terms, set-aside provisions, incumbent contractor information, or specific funding amounts are detailed within this mechanical demolition plan document. The plan serves as a technical specification and guide for contractors performing the mechanical demolition and preparation work as part of the overall high school renovation project. Southern A&E, LLC holds Professional Engineer Firm License No. PEF003374, valid through June 30, 2026, and retains all copyright and proprietary rights to the document.

View the file

Other files

File Type Posted
P203_R1_AD2___PLUMBING_ENLARGED_PLANS.pdf PDF
E003_R2_AD2___MECHANICAL_EQUIPMENT_CONNECTION.pdf PDF
M126_R2_AD2_MECHANICAL_RENOVATION_PLAN__WING_.pdf PDF
E123_R2_AD2___WING_G__ELECTRICAL_DEMOLITION_P.pdf PDF
Advertisement _ RHS Renovations.pdf PDF
E135_R2_AD2___WING_F_G_K__ROOF__POWER_PLAN.pdf PDF
P106_R1_AD2___PLUMBING_ROOF_PLAN__ALTERNATE.pdf PDF
E117_R1_AD2___WING_E__POWER_PLAN.pdf PDF
ADDENDUM_2__COMPLETE.pdf PDF
E103_R2_AD2___WING_A__POWER_PLAN.pdf PDF
M128_R2_AD2_MECHANICAL_RENOVATION_PLAN__WING_.pdf PDF
M112_R2_AD2_MECHANICAL_DEMOLITION_PLAN__WING_.pdf PDF
M130_R2_AD2_MECHANICAL_RENOVATION_PLAN__WING_.pdf PDF
P102_R1_AD2___PLUMBING_RENOVATION_PLAN__PHASE.pdf PDF
P201_R1_AD2___PLUMBING_ENLARGED_PLANS.pdf PDF
M115_R2_AD2_MECHANICAL_DEMOLITION_PLAN__WING_.pdf PDF
M127_R2_AD2_MECHANICAL_RENOVATION_PLAN__WING_.pdf PDF
M125_R2_AD2_MECHANICAL_RENOVATION_PLAN__WING_.pdf PDF
E129_R2_AD2___MEZZ_LEVEL__WING_G__POWER_PLAN.pdf PDF
M129_R2_AD2_MECHANICAL_RENOVATION_PLAN__WING_.pdf PDF
M602_R2_AD2_MECHANICAL_EQUIPMENT_SCHEDULES.pdf PDF
M110_R2_AD2_MECHANICAL_DEMOLITION_PLAN__WING_.pdf PDF
M601_R2_AD2_MECHANICAL_EQUIPMENT_SCHEDULES.pdf PDF
E125_R2_AD2___WING_G__POWER_PLAN.pdf PDF
P202_R1_AD2___PLUMBING_ENLARGED_PLANS.pdf PDF
P103_R1_AD2___PLUMBING_RENOVATION_FLOOR_PLAN_.pdf PDF
M503_R2_AD2_MECHANICAL_EQUIPMENT_DETAILS.pdf PDF
Project Award Recommendation _ RHS HVAC.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DD

D1

D1

D1

D1

D1

D8

D8

D9

D13 D13

D12 D12

D1

WEIGHT ROOM

MECH.

MECH.

WALKWAY

WALKWAY

BALCONY

D10

D24

D3

D3

D3 D3

D3 D3

D3D3

D29

D29

D29 D29

FOR CONTINUATION REFER TO: 1/ M111

F O

R C

O N

T

IN

U A

T

IO

N

R E

F E

R T

O

M

D33

D34 D34

D39

D41 D41

D4D4

D44D44

D45D45 22

DRAWING NUMBER

REVISIONS

COPYRIGHT 2025 BY SOUTHERN A&E, LLC. ALL RIGHTS RESERVED.

THIS DOCUMENT IS THE PROPERTY OF SOUTHERN A&E, LLC AND SHALL

NOT BE COPIED OR REPRODUCED IN WHOLE OR IN PART WITHOUT

EXPRESSED WRITTEN CONSENT FROM SOUTHERN A&E, LLC.

10-31-2025

BID PACKAGE BP-1

SA&E PROJECT NUMBER

ORIGINAL SHEET SIZE: ARCH E1 (30" X 42")

A

TRUE

NORTH

2" GRIDS 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

B

C

D

E

F

G

H

I

J

K

L

M

N

KEYPLAN

RIDGELAND HIGH SCHOOL

RENOVATIONS TO:

WALKER COUNTY SCHOOLS

301 N CHEROKEE ST, LAFAYETTE, GA 30728

2478 HAPPY VALLEY RD, ROSSVILLE, GA 30741

746-0190

01-920-045

ISSUED FOR CONSTRUCTION

STATE BOARD OF REGISTRATION

FOR PROFESSIONAL ENGINEERS AND

LAND SURVEYORS

SOUTHERN A & E, LLC

ENGINEER FIRM

LICENSE NO: PEF003374

EXP. DATE - 06/30/2026

B

A

C

D E

F

G

H

J

K

M113

MECHANICAL DEMOLITION PLAN - WING G

MEZZANINE

SCALE: = 1'-0"

0 8 168

1/8"

1/8" = 1'-0"M113

1 MECHANICAL DEMOLITION PLAN - WING G MEZZANINE

KEYNOTE SCHEDULE

# KEYNOTE DESCRIPTION

D1 REMOVE EXISTING EXHAUST FAN. PREPARE EXISTING ROOF CURB FOR NEW EXHAUST FAN.

NEW FAN CAP TO MATCH EXISTING CURB OR PROVIDE ADAPTER CURB.

D3 EXISTING DUCTWORK IN SHOWN SOLID LINES TO REMAIN.

D4 REMOVE EXISTING AIR DISTRIBUTION DEVICES SHOWN IN DASHED LINES.

D8 REMOVE EXISTING CONDENSING UNIT AND ASSOCIATED REFRIGERANT PIPING. EXISTING

STEEP SUPPORT STAND SHALL REMAIN. SAND AND PAINT EXISTING STEEL SUPPORT STAND

IN PREPARATION FOR INSTALLATION OF NEW CONDENSING UNIT. PROVIDE ADDITIONAL

STEEL SUPPORT STAND IF REQUIRED TO ACCOMMODATE NEW UNIT AND MAINTAIN SERVICE

CLEARANCES.

D9 REMOVE EXISTING HEAT PUMP.

D10 EXISTING GRAVITY INTAKE/RELIFE HOOD TO REMAIN.

D12 REMOVE EXISTING GAS DUCT FURNACE. DISCONNECT GAS LINES AND CAP TEMPORARILY.

DISCONNECT ASSOCIATED DUCTWORK AND PREPARE FOR NEW UNIT. EXISTING FLUE VENTS

SHALL BE REUSED FOR NEW GAS DUCT FURNACE. REFER TO MANUFACTURER’S IOM FOR

COMPATIBILITY WITH EXISTING FLUE VENTS. MODIFY AS NECESSARY.

D13 REMOVE EXISTING AIR HANDLER AND ASSOCIATED ACCESSORIES. DISCONNECT ASSOCIATED

DUCTWORK AND PREPARE FOR NEW UNIT.

D24 EXSITING TO REMAIN.

D29 EXISTING AIR DISTRIBUTION DEVICES SHOWN IN SOLID LINES TO REMAIN.

D33 EXISTING PIPE CHASE HOUSING TO REMAIN.

D34 REMOVE EXISTING MAKE UP AIR UNIT AND ASSOCIATED ACCESSORIES EXISTING DUCTWORK

AND CONTROLS SHALL REMAIN. DISCONNECT ASSOCIATED DUCTWORK AND PREPARE FOR

NEW UNIT, EXISTING FLUE VENTS SHALL BE REUSED FOR NEW UNIT.

D39 REPLACE EXISTING DAMPER ACTUATOR WITH NEW. MATCH EXISTING. INTERLOCK WITH

EXISTING CONTROLS.

D41 DRAIN AND REMOVE EXISTING ABANDONED WATER-SOURCE HEAT PUMP PIPING IN

MECHANICAL ROOMS. TRIM AND CAP PIPING AT WALL PENETRATIONS.

D44 EXISTING LOUVER TO REMAIN.

D45 EXISTING WALL PROPELLER FAN TO BE ABANDONED IN PLACE.