This document is an architectural drawing for Building 60 Repairs at Portsmouth Naval Shipyard in Kittery, Maine, specifically the Second Floor Mezzanine Removals Plan. The drawing is prepared by Naval Facilities Engineering Systems Command (NAVFAC) Mid-Atlantic, with project number 1740579 and revision date of September 14, 2023. Amendment 009 was issued on March 16, 2026, with final submission dated October 1, 2025.
The plan details nine removal tasks to be performed on the second floor mezzanine, including: removal of the wood-framed mezzanine floor structure; removal of stud-framed gypsum board interior partition; removal of wood guardrail system; complete removal of stair structure including railings; removal of gypsum board ceiling; removal and salvage of historic beadboard ceiling (approximately 200 square feet) for later patching; removal of wooden ladder and attic hatch closure; removal of abandoned ductwork and equipment; and removal of 2x wood storage racks above the crane rail. The drawing coordinates with hazardous materials removal sheets and structural sheets. Historic beadboard materials in areas to be concealed by ceiling systems must be salvaged and reinstalled for patching. The document is marked unclassified and includes a legend, key plan, and graphic scale for reference.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
DN
C1
AD201
A1
AD201
C1
AD202
A1
AD202
A1
AD203
C1
AD221
A1
AD221
C1
AD222
abcdefgjknp e1 e2 e3 e4 e5 e6 e7
OPEN TO BELOW
OPEN TO BELOW
ROOF BELOW
SEE AD121
STORAGE STORAGESTORAGE
M201
STORAGE
M202
AA
'-7
'-1
0"
2 3
EXISTING BRIDGE CRANE
(ABOVE)
3' - 6" ±
3'
0"
25' - 1" ±
3/ 4"
C1
AD20314' - 3 3/4" ±
1/ 4"
9' -4
7' -8
'-1
0"
10'-8" ±
5' - 8 1/2" ± 10' - 5" ±
EXISTING DUCTWORK, SEE
MECHANICAL SHEETS, TYP.
EXISTING STAIR
EXISTING CMU
PARTITION
EXISTING STEP
EXISTING HISTORIC MASONRY
EXTERIOR WALL SYSTEM (TYP)
EXISTING WOOD
FRAMED MEZZ
FLOOR SYSTEM
REMOVE FLOOR SYSTEM. SEE
STRUCTURAL SHEETS.
REMOVE AND SALVAGE BEAD
BOARD CEILING
SATISFACTORY TO DATE
APPROVED
FOR COMMANDER NAVFAC
SEAL
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SHEET
NAVFAC DRAWING NO.
DESIGNER
DRAWN BY
CHECKED BY
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 14 SEP 2023
DESIGN MANAGER
PROJECT MANAGER
FEAD/PM&E
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
P O
R T
S M
O U
T H
N A
V A
L S
H
IP
Y A
R D
K
IT
T
E R
Y M
E
UNCLASSIFIED
UNCLASSIFIED
U N
C L
A S
S
IF
IE
D
ACTIVITY
1740579
T. CARLETON
L. LYONS
S. RUCINSKI
/1
/2
:5
:1
A
M
C U s e rs \m d o n o v a n \D o c u m e n ts \2
.2
B L
D G
A
R C
H
IT
E C
T U
R A
L -V m d o n o v a n
V F
X R
.r v t
AD105
B
R
E P
A
IR
S
S E
C O
N D
F L O
O R
M E
Z Z
A N
IN
E
R E
M O
V A
L S
P L A
N
RSH
JMR
MJD
K
IT
T E
R Y
M
E P
O R
T S
M O
U T
H N
A V
A L S
H
IP
Y A
R D
R O
IC
C
-M E
A D
SCALE: 1/8" = 1'-0"
B1
SECOND FLOOR MEZZANINE REMOVALS PLAN
MATCH LINE
PLAN
NORTH
1/8" = 1' - 0" 0 5' 10' 15' 30'
GRAPHIC SCALE(S)
KEY PLANGENERAL NOTES REMOVALS KEYNOTES LEGEND
11. SEE SHEET G-004A FOR GENERAL REMOVALS NOTES.
2. COORDINATE REMOVALS WITH HAZARDOUS MATERIALS REMOVALS
SHEETS.
3. REMOVE AND SALVAGE HISTORIC BEADBOARD FROM AREAS THAT
WILL BE CONCEALED BY A CEILING SYSTEM FOR LATER PATCHING.
FOR BIDDING ASSUME 200 SQUARE FEET OF REMOVING AND
REINSTALLING EXISTING BEADBOARD CEILING.
REMOVE WOOD FRAMED MEZZANINE FLOOR, SEE STRUCTURAL SHEETS.
REMOVE STUD FRAMED GYPSUM BOARD INTERIOR PARTITION.
REMOVE WOOD GUARDRAIL SYSTEM.
REMOVE STAIR STRUCTURE IN ITS ENTIRETY, INCLUDING RAILINGS.
REMOVE GYPSUM BOARD CEILING.
REMOVE AND SALVAGE BEADBOARD (ABOVE GYPSUM BAORD CEILING) CEILING FOR PATCHING,
SEE GENERAL NOTE 3.
REMOVE WOODEN LADDER AND FIX ATTIC HATCH IN CLOSED POSITION.
REMOVE ABANDONED DUCTWORK/EQUIPMENT.
REMOVE 2x WOOD STORAGE RACK ABOVE CRANE RAIL.
(THIS SHEET ONLY)
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
F
IN
A L
S U
B M
IS
S
IO
N
/0
1/
R
S H
A
M E
N D
M E
N T
/1
6/
R
S H
| Sheets |
| AD104 - SECOND FLOOR REMOVALS PLAN |
| AD105 - SECOND FLOOR MEZZANINE REMOVALS PLAN |
| AE104 - FIRST FLOOR MEZZANINE PART PLAN - WEST |
| AE105 - SECOND FLOOR PLAN |
| AE411 - ENLARGED ELEVATOR PLANS AND SECTIONS |
| AE441 - ENLARGED STAIR PLANS 2 |
| AE444 - STAIR DETAILS |
| AE511 - METAL PANEL DETAILS |
| AE530 - EXPANSION JOINT DETAILS 1 |
| AE531 - EXPANSION JOINT DETAILS 2 |
| AE601 - DOOR SCHEDULE AND DETAILS |
| AE640 - ROOM FINISH SCHEDULE |
| HM101 - FIRST FLOOR HAZARDOUS MATERIALS PART PLAN - EAST |
| SP101 - STRUCTURAL PROTECTION PART PLAN AND DETAILS |
File details come from the government source that posted it. Updated .