257_EP503_R1_AMENDMENT 009.pdf
PDF 363 KB Posted
- Solicitation number
- N6247026R0012
About this file
This document is a Mechanical, Plumbing, and Miscellaneous Equipment Wiring Schedule that specifies electrical requirements for building systems and equipment installations. The schedule serves as a technical specification for electrical contractors detailing disconnect fuse wire, conduit sizes, and panelboard connections for HVAC, plumbing, and related mechanical equipment.
The schedule provides comprehensive wiring specifications for multiple equipment types, including air handling units (AHU-1, DOAS-1), outdoor units (OU-1 through OU-4), indoor units (IU-1 through IU-4), condensing units (CU-1 through CU-4), backup units (BCU-1 through BCU-3), pump systems (P-1A, P-1B), and circulation/heating units (CR-1, UH 1-1 through UH 3-4). Each equipment entry specifies the electrical panel designation (EP102 through EP107), voltage (120V, 208V, or 480V), phase configuration (1 or 3 phase), amperage ratings, horsepower where applicable, fuse ratings, wire gauge specifications, and conduit sizes. General notes indicate that indoor units are powered by outdoor units; motor-rated toggle disconnects are required; manufacturers' requirements must be followed for certain installations; and branch circuits, starters, contractors, and wiring accessories must be provided per contract documents. The schedule continues on sheet EP504 and is marked as UNCLASSIFIED with a revision date of 3/16/2026.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FUSEDISCONNECT
WIRE AND
CONDUIT SIZE
SERVING
PANELBOARD
FLAPHASE
MECHANICAL, PLUMBING, AND MISCELLANEOUS EQUIPMENT WIRING SCHEDULE
VOLTSEQUIPMENT SHEET # NOTES
60A60A, WP3#6, 1#10G, 3/4"CMSB3480EP104CU-4 36.8A
WATTS/
MECHANICAL, PLUMBING, AND MISCELLANEOUS EQUIPMENT WIRING SCHEDULE NOTES:
1. INDOOR UNIT IS POWERED BY THE OUTDOOR UNIT.
2. PROVIDE MOTOR RATED TOGGLE DISCONNECT SWITCH.
3. [OPTION 3] PROVIDE.
AHU-1
DOAS-1
CU-1
IU-2
IU-4
OU-1
IU-1
-100A, WPMSBEP104 10 -
20AMH13480EP104 16.36A- -
-MH13480EP105 7.5A- -
-30APER MANUFACTURERS REQUIREMENTS1208EP102 -- 1
-30A1208EP102 -- 1
-30A1208EP102 - 1
-30A, WP2#10, 1#10G, 3/4"CPL61208EP105 - -
IU-3 -30A1208EP105 -- 1
OU-2 -30A, WPTPP11208EP105 12A- -
EF-1 -30APL21120EP104 5.8A1/4HP -
P-1A -30AMSB3480EP102 11A7.5 HP -
P-1B -30A3480 11A7.5 HP -
CR-1 (A) -30A3480EP102 4.8A3 HP
UH 1-1 --AL11120EP103 3.2A1/12 2
UH 1-2 --1120EP103
UH 1-3 --1120EP103
HP
12A
EP102 MSB
CR-1 (B) -30A3480EP102 4.8A3 HP -
UH 1-4 --1120EP103
480 3 67A
30A
30A, WP
EP104DOAS-1, LIGHTS --ML1- -120 1 2.61A
EP104DOAS-1, RECEPTACLE --ML1- -120 1 8A
EP104CU-2 -PH1- -3 6.7A
EP104CU-3 -PH1- -3 7.5A
OU-3 -30A, WPTPP21208EP104 12A- -
OU-4 -30A, WP2#10, 1#10G, 3/4"CPL61208EP105 16A- -
BCU-1 -30AMH13480EP104 3.3A- -
BCU-2 -30A3480 2.5A- -
BCU-3 -480EP106 2.5A- -3
EP106 PH1
PH1 30A
3.2A1/12
3.2A1/12
3.2A1/12
AL1
AL1
AL1
UH 1-5 --1120EP103 3.2A1/12 AL1
UH 1-6 --1120EP103 0.2A25W AL1
UH 1-7 --2#12, 1#12G, 3/4"C1120EP102 PL4
UH 1-8 --1120EP102 PL4
UH 1-9 --1120EP102 PL1
UH 1-10 --1120EP102 PL2
UH 1-11 --1120EP104 ML2
UH 1-12 --1120 ML2
UH 1-13 --1120
ML1UH 1-14 --1120
ML1UH 1-15 --1120
ML2UH 1-16 --1120
ML1UH 1-17 --1120
ML2UH 1-18 --1120EP104
PL10UH 2-1 --1120EP105
PL10UH 2-2 --1120
PL10
2.2A1/20
4A1/8
2.2A1/20
UH 2-3 --1120
PL9UH 2-4 --1120
0.2A25W
2.2A1/20
UH 2-5 --1120 PL9
UH 2-6 --1120 PL8
1/20
1/20
UH 2-7 --1120 PL81/20
UH 2-8 --1120 PL8
UH 2-9 --1120EP105 PL8
1/20
1/20
UH 2-10 --1120EP106 PL7
UH 2-11 --1120EP106 PL7
0.2A25W
0.2A25W
UH 3-1 --1120EP107 PL10
UH 3-2 --1120 PL8
UH 3-3 --1120 PL8
UH 3-4 --1120EP107 PL7
0.2A25W
0.2A25W
0.2A25W
0.2A25W
0.2A25W
0.2A25W
0.2A25W
0.2A25W
0.2A25W
0.2A25W
0.2A25W
MSB
MSB
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
EP107
EP107
EP105
EP105
EP105
EP105
EP105
EP105
EP105
EP104
EP104
EP104
EP104
EP104
EP104
ML2
2.2A
2.2A
2.2A
2.2A
2.2A
1/20
1/20
1/20
1/20
2.2A
2.2A
2.2A
2.2A
TF-1 -30A1120EP102 MDP 22#12, 1#12G, 3/4"C- 4A
30A, WP
30A, WP
(SCHEDULE CONTINUED ON SHEET EP504)
3#2, 1#8G, 1-1/4"C
3#10, 1#10G, 3/4"C
2#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
3#12, 1#12G, 3/4"C
3#12, 1#12G, 3/4"C
3#12, 1#12G, 3/4"C
2#12, 1#12G, 3/4"C
PER MANUFACTURERS REQUIREMENTS
PER MANUFACTURERS REQUIREMENTS
PER MANUFACTURERS REQUIREMENTS
2#10, 1#10G, 3/4"C
2#10, 1#10G, 3/4"C
3#12, 1#12G, 3/4"C
3#12, 1#12G, 3/4"C
3#12, 1#12G, 3/4"C
3#12, 1#12G, 3/4"C
3#12, 1#12G, 3/4"C
3#12, 1#12G, 3/4"C
3#12, 1#12G, 3/4"C
UH 1-19 --2#12, 1#12G, 3/4"C1120EP103 AL12.2A1/20 2
SATISFACTORY TO DATE
APPROVED
FOR COMMANDER NAVFAC
SEAL
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SHEET
NAVFAC DRAWING NO.
DESIGNER
DRAWN BY
CHECKED BY
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
DRAWFORM REVISION: 14 SEP 2023
DESIGN MANAGER
PROJECT MANAGER
FEAD/PM&E
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
P O
R T
S M
O U
T H
N A
V A
L S
H
IP
Y A
R D
K
IT
T
E R
Y M
E
UNCLASSIFIED
UNCLASSIFIED
U N
C L
A S
S
IF
IE
D
ACTIVITY
1740579
T. CARLETON
L. LYONS
S. RUCINSKI
/1
/2
:4
:5
A
M
C U s e rs \b d a ig le \D o c u m e n ts
\2
.2
B
L D
G
E
L E
C -V b d a ig le
Q U
X G
.r v t
EP503
B R
E P
A
IR
S
M E
C H
A N
IC
A
L
P L U
M B
IN
G
A
N D
M
IS
C E
L L A
N E
O U
S E
Q U
IP
M
E N
T W
IR
IN
G S
C H
E D
U L E
DCL
HRM
BPD
K
IT
T E
R Y
M
E P
O R
T S
M O
U T
H N
A V
A L S
H
IP
Y A
R D
R O
IC
C
-M E
E P
GENERAL NOTES
1. PROVIDE DISCONNECT AND STARTERS AS INDICATED IN THE
SCHEDULE AND ON THE PLANS.
2. COORDINATE DISCONNECT AND STARTER LOCATIONS IN THE FIELD
TO PROVIDE CLEARANCES REQUIRED BY NEC. PROVIDE MIN 30
INCHES WIDE, 36 INCHES DEEP (120/208V) OR 42 INCHES DEEP
(480V), AND 6 FOOT-7 INCHES HIGH WORKER CLEARANCE. REFER
TO NEC 110.26.
3. PROVIDE STARTERS, CONTACTORS, WIRING, AND ACCESSORIES AS
REQUIRED TO ACHIEVE OPERATION AND SEQUENCE OF
OPERATION PER THE CONTRACT DOCUMENTS.
4. PROVIDE BRANCH CIRCUITS INDICATED IN THE SCHEDULES AND ON
THE PLANS.
5. PROVIDE FUSES. COORDINATE FINAL SIZES WITH EQUIPMENT
PROVIDED.
6. COORDINATE WITH THE HVAC CONTROLS INSTALLER AND PROVIDE
CONDUIT FOR CONTROLS WIRING.
7. PROVIDE FULL SIZE LIQUID TIGHT METAL FLEXIBLE CONDUIT ONLY
FOR FINAL CONNECTION FROM STARTERS AND VFD'S TO MOTORS
AND FROM DISCONNECTS TO VIBRATING EQUIPMENT AND
MOTORS. MAXIMUM LENGTH OF LIQUID TIGHT METAL FLEXIBLE
CONDUIT TO BE 6'.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
F
IN
A L
S U
B M
IS
S
IO
N
/0
1/
R
S H
A
M E
N D
M E
N T
/1
6/
R
S H
| Sheets |
| EP503 - MECHANICAL, PLUMBING, AND MISCELLANEOUS EQUIPMENT WIRING SCHEDULE |