This document contains an interior construction specification section for a solicitation seeking design-build construction services. Key details include the solicitation requiring construction of a 36,139 square foot National Guard Readiness Center in Barrigada, Guam to support training, administrative, and logistical functions. Functional areas for the new facility include administrative space, arms vaults and cages, classrooms, and unit lockers. The solicitation is issued as an unrestricted procurement using a best-value tradeoff source selection evaluating technical proposal, past performance, and price. A pre-proposal conference will be held on May 4th and questions are due by April 28th. The estimated value of the construction project is between $25-100 million. Offerors must submit a bid bond of $3,000,000 or 20% of the bid price, whichever is less.
View the file
Other files
Show all 50
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FY22 National Guard Readiness Center WON 1674991 Barrigada, Guam Part 3 Chapter 6 C10 Interior Construction
Final DB-RFP Submittal
PART 3 - CHAPTER 6 / ESR C10 - Page 1
C10 INTERIOR CONSTRUCTION
SYSTEM DESCRIPTION
Interior construction includes interior partitions, interior doors, and fittings.
Provide durable construction appropriate for the building function. Acoustic properties of materials, as well as durability, shall be considered during material selection.
GENERAL SYSTEM REQUIREMENTS
Areas of the Project subject to abuse require that "impact Resistant" systems be provided. See "Room Requirements" for specific requirements on "Partitions", "Interior Doors", and "Fittings".
C1010 PARTITIONS
All exposed metal connectors and fasteners for exterior, non-conditioned masonry work shall be epoxy paint protected ASTM A316L stainless steel. A316L stainless steel is available at a lower yield strength than A992 steel and its weldability can sometimes be an issue if not done properly per specific welding requirements for that particular material. All metal connectors and fasteners for interior masonry shall be hot-dipped galvanized.
Masonry interior walls in non-conditioned interior spaces and exterior screen walls shall be reinforced, fully grouted and shall have a protective silicone enhanced EFS or similar coating to protect reinforcement and metal connections from corrosion that may be caused by wind driven rains and the corrosive marine environment.
Only Type II and I/II cement meeting ASTM C150 Type II criteria is allowed.
All interior partitions shall be concrete masonry, cast-in-place concrete, pre-cast concrete or metal studs with paperless gypsum board each side.
All metal stud partitions adjacent to any space where moisture may be present (shower, toilet, janitor's room/closet, food preparation areas, laundry rooms, etc.) shall be installed on a 4 inch (100 mm) minimum high concrete curb. All gypsum board shall be paperless (no cellulose material) gypsum board. Paperless gypsum wallboard shall be 5/8-inch (16 mm) minimum glass mat (both sides) wallboard. Light gage interior metal framing shall be G90. Metal studs shall be cold-formed with a minimum coating of Z275 G90 and use ceramic-coated screws. Apply sealer over all screw heads.
The ceramic screws consist of zinc coated steel screws that are entirely coated (head, shank, and threads) with ceramic. The bottom metal floor track shall have a continuous foam strip made for separating the bottom track from the concrete floor slab. Metal partition floor tracks shall be vacuumed to remove all debris and sprayed with a mold resistant coating sealer to help control mold just before closing with paperless gypsum wallboard. Provide a 1/2-inch (14 mm) gap from the top of finish flooring to the bottom of the wallboard to prevent water from wicking up the wallboard. Provide a one-hour rated partitions where required. All paperless gypsum board wall partitions shall be finished to Level 4 in accordance with Gypsum Association GA 214. All interior wall corners and jambs shall receive bullnose finish.
Exterior shell furring framing for insulation shall be spaced with non-continuous clips from the exterior walls or roof.
In unconditioned spaces, the light gauge metal framing shall not directly contact concrete and shall be
PART 3 - CHAPTER 6 / ESR C10 - Page 2 provided with a continuous separation that is the width of the floor or wall channels.
Concrete mixture shall provide an average compressive strength of 3000 PSI (20,680 kPa) and meet or exceed ACI 301/301M.
C101001 FIXED PARTITIONS
Provide fixed interior partitions, except where demountable or retractable partitions are specifically required by the "Room Requirements." Sound-rated partition assemblies shall have a minimum Sound Transmission Coefficient (STC) of 42 in accordance with ASTM E 90 or ASTM E 413 for frequency data. Provide minimum STC rated of 42 to all interior fixed partitions and doors except for utility rooms, storage, vaults and cages.
The dividing wall between a space with large exterior doors or openings (such as Garages, Loading & Storage areas) and the interior of the unit or facility shall be designed to meet the minimum design loads indicated in the latest edition(s) of ASCE 7 and the IBC with due consideration for topographic and geographic features that may amplify wind loads by applying the appropriate Kzt topographic factor and using the appropriate exposure category in the event the door fails during a typhoon.
C101002 DEMOUNTABLE PARTITIONS
Demountable partitions include sound rated, full height (floor to ceiling) solid partitions. Sound-rated partition assemblies shall have a minimum Sound Transmission Coefficient (STC) of 42 in accordance with ASTM E 90 or ASTM E 413 for frequency data. Demountable partitions be funded as part of FF&E.
Provide fabric finish for demountable partitions.
C101003 RETRACTABLE PARTITIONS
Provide retractable partitions to include operable panel partitions. Sound-rated partition assemblies shall have a minimum Sound Transmission Coefficient (STC) of 42 in accordance with ASTM E 90 or ASTM E 413 for frequency data. Retractable partitions shall be with fabric finish.
C101004 INTERIOR GUARDRAILS AND SCREENS
Not used.
C101005 INTERIOR WINDOWS
Not used.
C101006 GLAZED PARTITIONS & STOREFRONTS
Provide glazed storefront system.
C101007 INTERIOR GLAZING
Interior glazing shall be clear glass, laminated glazing.
C1020 INTERIOR DOORS
C102001 STANDARD INTERIOR DOORS
PART 3 - CHAPTER 6 / ESR C10 - Page 3
All interior doors shall be flush.
All interior doors shall be wood, except where hollow metal doors are required to meet fire rating. All interior door frames shall be hollow metal, galvanized steel.
Provide heavy duty metal doors and metal frames for Arm Vaults.
Stile and rail wood doors shall be WDMA I.S.6A-01, premium custom grade, heavy duty.
Flush wood doors shall be WDMA I.S.1A-04, premium] custom grad Flush wood doors shall be WDMA I.S.-97 SCLC-5 5-ply structural composite lumber core.
Building standard doors to comply with WDMA I.S.1A Premium Grade. Doors adjacent to paneling or millwork to comply with corresponding AWI millwork grade.
Veneer for flush doors shall be species in veneer match.
Doors shall have Factory Finish of AWI Quality Standards Section 1500, specification for catalyzed polyurethane or acrylated uv curable epoxy field finish.
C102002 GLAZED INTERIOR DOORS
Provide vision glazing in doors where it is required by the “Room Requirements” portion of this RFP, or it is deemed advantageous to be able to see through the door, either for safety of pedestrian traffic, or other functional reason.
C102003 FIRE DOORS
Provide interior fire doors.
C102004 SLIDING AND FOLDING DOORS
Not used
C102005 INTERIOR OVERHEAD DOORS
Not used.
C102006 INTERIOR GATES
Not used.
C102007 INTERIOR DOOR HARDWARE
Provide special door hardware, such as combination locks card key system, Provide card key type access units for specialized entries. Provide lithium battery powered, magnetic stripe keycard locksets that are ANSI/BHMA A156.13, Series 1000, Grade 1, mortise ANSI/BHMA A156.2, Series 4000, Grade 1, cylindrical locks, tamper resistant, UL listed with 1 inch (25 mm) throw deadbolt, 3/4-inch throw latch bolt, auxiliary dead-locking latch, and 2-3/4-inch (68.75 mm) backset.
Door hardware finish shall be chrome-plated brass or bronze, or 316L stainless steel 630 finish satin
PART 3 - CHAPTER 6 / ESR C10 - Page 4 stainless steel brass or bronze.
All door hardware and fasteners be 630 finish (satin stainless steel) to address corrosion prevention measures. Nonferrous metals (i.e., door closers) shall have matching colors to the rest of the door hardware. No plated steel hardware shall be used on the exterior or interior of any facility in Guam. As required, provide top and bottom door bolts, door weather stripping, automatic door bottoms, door saddles, door strips, hinged ADA hardware as required, locksets, latch sets, dead bolts, door closers, view holes, access hardware such as card readers and so forth.
Hardware shall match finish of the doors as well as windows as much as possible.
C102090 OTHER INTERIOR SPECIALTY DOORS
Not used.
C102091 OTHER INTERIOR PERSONNEL DOORS
Not used.
C1030 SPECIALTIES
C103001 COMPARTMENTS, CUBICLES, & TOILET PARTITIONS
Provide high density polyethylene (HDPE) toilet partitions and urinal screens in all toilet rooms with more than one water closet or urinal. All toilet partition and urinal screen hardware, fasteners and connections shall be anodized aluminum or 316L stainless steel. Provide toilet accessories as indicated in Chapter 3, “Room Requirements” portion of this RFP.
C103002 TOILET AND BATH ACCESSORIES
Provide toilet and bath accessories.
All toilet and bath accessories shall use 316L stainless steel fasteners. All accessories including but not limited to grab bars, robe hooks, waste receptacles, towel bars and soap, paper towel, toilet tissue and toilet seat dispensers shall be stainless steel.. Mount mirrors on 6 mm (1/4”) furring strips for ventilation behind mirror to deter mold growth.
Mounting or backing support for accessories shall be a minimum of galvanized G90 steel. Wood backing shall be avoided, but if used must be termite treated.
C103003 MARKER BOARDS AND TACK BOARDS
Provide marker boards and tack boards as indicated in Chapter 5 "Room Requirements" portion of this RFP. Marker boards and tack boards are funded as part of the construction contract.
C103004 IDENTIFYING DEVICES
All necessary interior signage shall be incorporated as part of the architectural drawings. Interior signage is not collateral equipment. Interior signage shall demonstrate complete coordination with the facility design, SID, and FF&E submittals. Provide interior directional signage as required for facility way finding. Provide an identifying device at each interior door. Signage must meet ADA and IBC requirements as well as other applicable requirements, such as Base/Installation, UFC, and
PART 3 - CHAPTER 6 / ESR C10 - Page 5 government agency requirements such as Department of Health.
All interior signage shall be plastic All interior signage mounting hardware and fastening devises shall be 316L stainless steel.
C103005 LOCKERS
Provide lockers. Lockers shall Lockers are funded as part of the construction contract. All fasteners, connectors and brackets shall be 316L stainless steel.
C103006 SHELVING
Provide veneer core plywood or stainless-steel shelving. Built-in fixed shelving is funded as part of the construction contract.
All wood shelving shall be termite treated except where food products, dishes, and utensils could be stored. Termite treatment shall be waterborne-type and shall not result in warping, odor or require incisions. All exposed termite treatment shall result in a clear finish. All metal connections and fasteners in termite treated wood shelving shall be ASTM 316L stainless steel.
C103007 FIRE EXTINGUISHER CABINETS
Provide fire extinguisher cabinets. Cabinet shall be semi-recessed in new construction and surface-mounted in new mechanical/electrical spaces and existing wall construction. Cabinets shall be coordinated with interior finishes
All fire extinguisher cabinets, fasteners and hardware shall be stainless steel with factory paint finish.
C103008 COUNTERS
Provide solid polymer counter tops and back splashes.
Provide integral sink / lavatory at all bathrooms.
All backsplashes shall be a minimum of 4 inches (100 mm) high with curved outside edges and coved inside corners.
Where exterior windows are adjacent to countertops dark colored countertops shall be avoided to minimize noticeable fading from ultraviolet light exposure. All solid-colored countertops shall be avoided.
C103009 CABINETS
Provide cabinetry and millwork items with associated accessories. Cabinetry shall be AWI premium grade and have concealed hinges with adjustable standards for shelves. All exposed surfaces will be veneer core plywood.
All wood cabinets shall be termite treated except where food products, dishes, and utensils could be stored. Termite treatment shall be waterborne-type and shall not result in warping, odor or require incisions. All exposed termite treatment shall result in a clear finish. All metal connections and fasteners in termite treated wood shall be ASTM 316L stainless steel.
PART 3 - CHAPTER 6 / ESR C10 - Page 6
Provide specific cabinetry as shown on the Room Requirements Sheets.
C103010 CASEWORK
Provide specific casework as shown on the Room Requirements Sheets.
C103011 CLOSETS
Not used.
C103012 FIRESTOPPING PENETRATIONS
Provide all sleeves, caulking, and flashing for firestopping penetrations.
C103013 SPRAYED FIRE-RESISTIVE MATERIALS
Not used.
C103014 ENTRANCE FLOOR GRILLES AND MATS
Provide recessed pan floor mats at main building entrances.
All floor mats shall utilize 316L stainless steel or other similar heavy duty corrosion resistant material and components.
Provide floor drains with trap primers at all entrances and backwater sewer valve to collect wind driven water at entrance areas.
C103015 ORNAMENTAL METAL WORK
Not used.
C103090 OTHER INTERIOR SPECIALTIES
Provide ceiling mounted motorized projection screen as approved by client.
--End of Section--
| C10 INTERIOR CONSTRUCTION |
| SYSTEM DESCRIPTION |
| C1010 PARTITIONS |
| C101001 FIXED PARTITIONS |
| C101002 DEMOUNTABLE PARTITIONS |
| C101003 RETRACTABLE PARTITIONS |
| C101004 INTERIOR GUARDRAILS AND SCREENS |
| C101005 INTERIOR WINDOWS |
| C101006 GLAZED PARTITIONS & STOREFRONTS |
| C101007 INTERIOR GLAZING |
| C1020 INTERIOR DOORS |
| C102001 STANDARD INTERIOR DOORS |
| C102002 GLAZED INTERIOR DOORS |
| C102003 FIRE DOORS |
| C102004 SLIDING AND FOLDING DOORS |
| C102005 INTERIOR OVERHEAD DOORS |
| C102006 INTERIOR GATES |
| C102007 INTERIOR DOOR HARDWARE |
| C102090 OTHER INTERIOR SPECIALTY DOORS |
| C102091 OTHER INTERIOR PERSONNEL DOORS |
| C1030 SPECIALTIES |
| C103001 COMPARTMENTS, CUBICLES, & TOILET PARTITIONS |
| C103002 TOILET AND BATH ACCESSORIES |
| C103003 MARKER BOARDS AND TACK BOARDS |
| C103004 IDENTIFYING DEVICES |
| All interior signage shall be plastic All interior signage mounting hardware and fastening devises shall be 316L stainless steel. |
| C103005 LOCKERS |
| C103006 SHELVING |
| C103007 FIRE EXTINGUISHER CABINETS |
| C103008 COUNTERS |
| C103009 CABINETS |
| C103010 CASEWORK |
| C103011 CLOSETS |
| C103012 FIRESTOPPING PENETRATIONS |
| C103013 SPRAYED FIRE-RESISTIVE MATERIALS |
| C103014 ENTRANCE FLOOR GRILLES AND MATS |
| C103015 ORNAMENTAL METAL WORK |
| C103090 OTHER INTERIOR SPECIALTIES |