This solicitation is for the design and construction of a 36,139 square foot National Guard Readiness Center in Barrigada, Guam to support the 1224th Engineer Support Company and 1-244th Aviation Regiment. Key requirements include administrative areas, arms vaults and cages, classrooms, and unit locks. The estimated price range for construction is between $25-100 million. Offerors must submit technical and past performance proposals as well as pricing for evaluation. A bid bond of $3 million or 20% of the bid price, whichever is less, is also required. The pre-proposal conference will be held on May 4th, with any questions due by April 28th. Proposals must be submitted through the System for Award Management website. The Naval Facilities Engineering Command is the contracting agency.
View the file
Other files
Show all 50
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT:
LOCATION: Barrigada, Guam Date: 28 December 2021
SAES
3/31/2021
Current Layout
Functional Program Area NSF GSF PN Remarks*
17180 Readiness Center A. Common Use Area
Classrooms & Learning Center 2,960 3,190 Breakroom 300 345 Toilets/Restrooms + Showers 1,780 1,150 Janitor Room 50 Lactation Area 80 95 Covered Entrances 198 Main Entrance, Service entrances/exits (calc. as half area)
Subtotal: 5,120 5,028 B. Unit and Special Space Allowance
Administrative Office Space: 4,500 ESC: 6 private officers 913 ESC: open office w/ 8 desks/cubicles 1,064 ESC: medical supply room 364 ESC: surveyor storage room 367 ESC: copier area 95 AVN: 3 private officers 440 AVN: open office w/ 4 cubicles 875 AVN: 1 office + 400 SF Ops w/ counter 632 AVN: Briefing room 400 AVN: POL/Fuels Lab 200
Unit Storage Space: 5,761 Arms Vaults 1,254 ESC: 5 Cages + supply/general storage 2,624 ESC: Arms sgt. work station 94 AVN: LSE + NVG office 986 AVN: Cage w/ supply and medical storage 1,019
Locker Room Space: 3,042 3,252 169 Basic Space 200 200
Special Function:
General Purpose Training Bay 3,168 3,281 General Purpose Training Bay, Support Spaces: 810
Support Office 275 Unisex restroom 80 POL Room 167 Mechanical room 172 Circulation 98
Generator Building 375 375 GSF does not include air well area Subtotal: 17,481 19,227
C. Maintenance and Storage (3% of Net Area) 679 D. Mechanical/Electrical Rooms (5% of Net Area) 1,131 1,866 Mech room, Elec room, Elec closets E. Telecom/IT Room (1% of Net Area) 227 157 F. Circulation Allowance (15%-22% of Net Area) 3,696 5,265 Lobby, Hallway 1-5 G. Structural Allowance (10% of Net Area) 2,834
Subtotal: 8,567 7,288 44224 Unheated Storage Building
A. Detached Unheated Storage Space 3,929 4,596 B. Circulation Allowance (15% of Net Area) 590 C. Structural Allowance (10% of Net Area) 452
Subtotal: 4,971 4,596
PRIMARY FACILITY/BUILDING AREA Total: 36,139 36,139 169
National Guard Readiness Center
Separate building (combined with unheated storage bldg)
Separate building (combined with GPTB)
4_Figure 1_Space Tabulation_Rev1.xlsx Page 1 Setiadi Architects LLC
NGRC-20211228
File details come from the government source that posted it. Updated .