Amendment 0003 - A-407 REV1.pdf
PDF 226 KB Posted
- Solicitation number
- N4008526R0002
About this file
This is an architectural drawing for a walk-in freezer facility, specifically sheet A-407 titled "Enlarged Plan & Sections - Walk-In Freezer" for the P-995 Composite Repair Facility at Marine Corps Air Station Cherry Point, North Carolina.
The drawing provides detailed construction specifications for a walk-in freezer installation, including an enlarged plan view at 1/4" = 1'-0" scale, a freezer detail section at 3/4" = 1'-0" scale, and a section view at 1/4" = 1'-0" scale. Key design elements specified include manufacturer's insulated wall panels, roof panels, and door panel; standard wall panels with base plates; a 4-inch concrete slab over insulation; 1.5-inch rigid underslab insulation with crystalline waterproofing; preservative and fire-retardant treated 2x6 members at the wall panel edge; and 4-inch underslab insulation. The freezer dimensions are 25 feet 4 inches by 14 feet. The drawing was prepared by MBF Architects and approved by Erik A. Lewis, Infrastructure Engineering Branch Head at FRCE Cherry Point, with a revision date of April 7, 2026 and a document date of December 24, 2025. This document is part of a Naval Facilities Engineering Systems Command (NAVFAC) Mid-Atlantic project under the Department of the Navy.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
25' - 4"EQ. EQ.
E Q
E
Q
WALK-IN FREEZER MANUFACTURER'S
INSULATED WALL PANELS, ROOF
PANELS AND DOOR PANEL AS SPECIFIED
A4
A-407
A-407 A3
4" 4"
4"
1'
0"
WALK-IN FREEZER MANUFACTURER'S
STANDARD WALL PANEL AND BASE
PLATE AS SPECIFIED
4" UNDERSLAB INSULATION
PRESERVATIVE AND FIRE-RETARDANT
TREATED 2X6 AT EDGE OF WALL PANEL
4" CONCRETE SLAB OVER INSULATION8"
1-1/2" RIGID INSULATION UNDERSLAB W/
CRYSTALLINE WATERPROOFING
BETWEEN INSULATION AND SLAB: FULLY
BENEATH FREEZER TO EXTENT
INDICATED AT PERIMETER
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
SCALE:
STA. PROJ. NO.:
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
EPROJECT NO.:
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
D E S
IG
N A
N D
C O
N S T R U
C T
IO
N
D C
C O
R E
N A V A L S
T A T
IO
N
N O
R F O
L K V A
M A
R
IN
E C
O R
P S
A
IR
S T
A T
IO
N
C H
E R
R Y
P O
IN
T
N
C
F ile
P ri n t
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
M
A
P.
STCETIHCRA
FB
BERN N.C
.NEW
CERT. NO.
UTCETIHCRA
DERET
SI
G E R
NO
IT
AR
OP
RO
C
LAR
CAROLINANORTH
50679
T
T C
E
TI
HCRAD
R E
G I S
ERE
A N
I
L
ORA
N O
R
T H
C
N
D A
R
N
DE
.J UE
ER
III
C
N
NRB E
E W
AS INDICATED
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
A T
L A
N T
IC
Approved by Erik A. Lewis, Infrastructure Engineering Branch Head, FRCE Cherry Point via Electronic Signature
C U s e rs \g ri ff it h \D o c u m e n ts
\2
A
R C
H g ri ff ith m b fa rc h it e c ts
.c o m .r v t
/8
/2
:1
:4
P
M
E N
L A
R G
E D
P L
A N
S
E C
T
IO
N S
W
A L
K -I
N F
R E
E Z
E R
A-407
1692230
P -9
C
O M
P O
S
IT
E R
E P
A
IR
F A
C
IL
IT
Y
12938292
12/24/2025
DLG DLG DJE
KTB/SOM
CGM
JWJ
HPN
24 DECEMBER 2025
SCALE: 1/4" = 1'-0"
C4
ENLARGED PLAN AT WALK-IN FREEZER
SCALE: 1/4" = 1'-0"
A4
SECTION AT WALK-IN FREEZER
SCALE: 3/4" = 1'-0"
A3
FREEZER DETAIL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
A m e n d m e n t
.0
.0
| Sheets |
| A-407 - ENLARGED PLAN & SECTIONS - WALK-IN FREEZER |
| 2026-04-14T12:29:33-0400 | |
| Norfolk, VA | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
2026-04-14T12:30:01-0400
File details come from the government source that posted it. Updated .