Amendment 0003 - 08 71 00.pdf
PDF 645 KB Posted
- Solicitation number
- N4008526R0002
About this file
SECTION 08 71 00 – DOOR HARDWARE SPECIFICATION
This is a technical specification section for door hardware required for the P-995 Composite Repair Facility construction project at MCAS Cherry Point, North Carolina, with an effective date of December 24, 2025 (Revised Amendment 002 – April 9, 2026).
The specification establishes comprehensive requirements for door hardware installation, including hinges, locks, latches, exit devices, cylinders, cores, keying systems, closers, thresholds, weatherstripping, and auxiliary hardware. All hardware must comply with ANSI/BHMA standards (A156.1 through A156.36), ASTM E283 for air leakage testing, SDI/DOOR A250.8 for standard steel doors and frames, and ADA accessibility guidelines per 36 CFR 1191. Hardware items must be manufactured using templates per ANSI/BHMA A156.7 and clearly marked with manufacturer identification. Exterior locations require full stainless steel type 302 or 304 construction in Marine Grade I, non-ferrous materials. The specification mandates BHMA 630 finish (satin stainless steel) for all hardware unless otherwise specified, with stainless steel fasteners required for weather-exposed locations. The keying system must extend the existing system using SFIC Series 7 pin, A Keyway manufactured by Best, with construction interchangeable cores and a key cabinet providing 50 percent greater capacity than required key changes. Contractors must submit detailed shop drawings, hardware schedules, product data, manufacturer instructions, and key bitting charts (including 20 percent additional key cuts) for government approval. A mandatory coordination meeting between the Contracting Officer, Contractor, Door Hardware Subcontractor, Cherry Point Base Locksmith, and facility representatives must occur prior to key shop drawing submission to confirm keying requirements, procurement, shipping, and installation procedures. The specification includes 21 distinct hardware sets (HWS-5 through HWS-21) for various door types, ranging from heavy-duty exterior electrical/mechanical/telecommunications doors to interior utility and access doors, with specifications for hinges, closers, locks, exit devices, weatherstripping, thresholds, kick plates, and supplemental hardware such as door stops and silencers. Selected hardware sets include provisions for access control equipment integration with fire alarm systems, electric strikes, card readers, and electric hinges, with associated electrical metallic tubing raceway and cabling requirements.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P-995 Composite Repair Facility 24 December 2025 MCAS Cherry Point, NC
SECTION 08 71 00
DOOR HARDWARE
02/16, CHG 4: 02/22
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM E283 (2019) Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen
BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)
ANSI/BHMA A156.1 (2021) Butts and Hinges
ANSI/BHMA A156.2 (2022) Bored and Preassembled Locks and Latches
ANSI/BHMA A156.3 (2020) Exit Devices
ANSI/BHMA A156.4 (2013) Door Controls - Closers
ANSI/BHMA A156.5 (2020) Cylinder and Input Devices for Locks
ANSI/BHMA A156.6 (2021) Architectural Door Trim
ANSI/BHMA A156.7 (2016) Template Hinge Dimensions
ANSI/BHMA A156.8 (2021) Door Controls - Overhead Stops and Holders
ANSI/BHMA A156.13 (2022) Mortise Locks & Latches Series 1000
ANSI/BHMA A156.16 (2023) Auxiliary Hardware
ANSI/BHMA A156.18 (2020) Materials and Finishes
ANSI/BHMA A156.21 (2019) Thresholds
ANSI/BHMA A156.22 (2021) Gasketing
ANSI/BHMA A156.36 (2010) Auxiliary Locks
STEEL DOOR INSTITUTE (SDI/DOOR)
SDI/DOOR A250.8 (2023) Specifications for Standard Steel Doors and Frames
SECTION 08 71 00 Page 1 REVISED Amendment 002 - 9 APR 2026
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
1.2 SUBMITTALS
Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for Contractor Quality Control approval. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Manufacturer's Detail Drawings ; G
Verification of Existing Conditions ; G
Hardware Schedule ; G
Keying System ; G
SD-03 Product Data
Hardware Items ; G
SD-08 Manufacturer's Instructions
Installation
SD-10 Operation and Maintenance Data
Hardware Schedule Items, Data Package 1; G
SD-11 Closeout Submittals
Key Bitting
1.3 SHOP DRAWINGS
Submit manufacturer's detail drawings indicating all hardware assembly components and interface with adjacent construction. Base shop drawings on verified field measurements and include verification of existing conditions .
1.4 PRODUCT DATA
Provide documentation of ABA/ADA accessibility compliance of applicable components, as required by 36 CFR 1191 Appendix D - Technical.
1.5 HARDWARE SCHEDULE
Provide Hardware Item List and Hardware Schedule containing the following information, and additional information as needed to identify the complete make up of each hardware set and its application to each opening:
SECTION 08 71 00 Page 2
1.5.1 Hardware Item List:
a. Hardware Type
b. Item Number
c. Quantity
d. Size(s)
e. Reference Publication / Type Number
f. Manufacturer's Name / Catalog Number
g. Key Control Symbols
h. UL Mark (If fire rated and listed)
i. BHMA Finish(es)
j. Remarks
1.5.2 Hardware Schedule
a. Hardware Set Number
b. Opening Number(s)
c. Opening Description (single/double leaf, hand, size, door/frame material)
d. Fire Rating
e. Sound Rating
f. Hardware Items
g. Quantity
h. Size
i. BHMA Finish
j. Remarks
In addition, submit hardware schedule data package 1 in accordance with Section 01 78 23 OPERATION AND MAINTENANCE DATA.
1.6 KEY BITTING CHART REQUIREMENTS
1.6.1 Requirements
Submit key bitting charts to the Contracting Officer prior to completion of the work. Include:
a. Complete listing of all keys (e.g. AA1 and AA2).
b. Complete listing of all key cuts (AA1-123456, AA2-123458).
SECTION 08 71 00 Page 3
c. Tabulation showing which key fits which door.
d. Copy of floor plan showing doors and door numbers.
e. Listing of 20 percent more key cuts than are presently required in each master system.
1.7 QUALITY ASSURANCE
1.7.1 Hardware Manufacturers and Modifications
Provide, as far as feasible, locks, hinges and closers of one lock, hinge or closer manufacturer's make. Modify hardware as necessary to provide features indicated or specified.
1.7.2 Key Shop Drawings Coordination Meeting
Prior to the submission of the key shop drawing, the Contracting Officer, Contractor, Door Hardware Subcontractor, using Activity and Base Locksmith must meet to discuss and coordinate key requirements for the facility.
Coordinate with the Cherry Point Base Locksmith to resolve keying, procurement, shipping and installation procedures. Confirm keyways utilized and provide compatible cylinders and cores. Confirm hardware set components and functions.
1.8 DELIVERY, STORAGE, AND HANDLING
Deliver hardware in original individual containers, complete with necessary appurtenances including fasteners and instructions. Mark each individual container with item number as shown on hardware schedule.
Deliver permanent keys and removable cores to the Contracting Officer, either directly or by certified mail. Deliver construction master keys with the locks.
PART 2 PRODUCTS
2.1 TEMPLATE HARDWARE
Hardware applied to doors must be manufactured using a template. Provide templates to door and frame manufacturers in accordance with ANSI/BHMA A156.7 for template hinges. Coordinate hardware items to prevent interference with other hardware.
2.2 HARDWARE ITEMS
Clearly and permanently mark with the manufacturer's name or trademark, hinges, locks, latches, exit devices, bolts and closers where the identifying mark is visible after the item is installed. For closers with covers, the name or trademark may be beneath the cover.
2.2.1 Hinges
Provide in accordance with ANSI/BHMA A156.1 . Provide hinges that are 4-1/2 by 4-1/2 inch unless otherwise indicated. Construct loose pin hinges for interior doors and reverse-bevel exterior doors so that pins are non-removable when door is closed. Other anti-friction bearing hinges may be provided in lieu of ball bearing hinges.
SECTION 08 71 00 Page 4
2.2.2 Locks and Latches
a. At exterior locations provide locksets of full stainless steel type 302 or 304 construction including fronts, strike, escutcheons, knobs, bolts and all interior working parts. Marine Grade I, fully non-ferrous.
b. In non-air-conditioned interior environments or humid interior environments, provide interior locksets on the same Marine Grade I, fully non-ferrous as exterior locksets.
2.2.2.1 Bored Locks and Latches
Provide in accordance with ANSI/BHMA A156.2 , Series 4000, Grade 1.
2.2.2.2 Auxiliary Locks
Provide in accordance with ANSI/BHMA A156.36 , Grade 1.
2.2.3 Exit Devices
Provide in accordance with ANSI/BHMA A156.3 , Grade 1. Provide adjustable strikes for rim type and vertical rod devices. Provide open back strikes for pairs of doors with mortise and vertical rod devices. Provide touch bars in lieu of conventional crossbars and arms. Provide escutcheons not less than 7 by 2-1/4 inch .
Provide stainless steel exit devices . Also include stainless steel fasteners and screws.
2.2.4 Cylinders and Cores
Provide cylinders and cores for new locks, including locks provided under other sections of this specification. Provide cylinders and cores with seven pin tumblers. Provide cylinders from the products of one manufacturer, and provide cores from the products of one manufacturer.
Rim cylinders and levers of bored locksets have interchangeable cores which are removable by special control keys. Stamp each interchangeable core with a key control symbol in a concealed place on the core.
2.2.5 Keying System
Provide an extension of the existing keying system. Provide SFIC Series 7 pin, A Keyway as manufactured by Best, www.bestaccess.com. Provide construction interchangeable cores. Provide key cabinet as specified.
2.2.6 Lock Trim
Provide cast, forged, or heavy wrought construction and commercial plain design for lock trim.
2.2.6.1 Lever Handles
Provide lever handles. Provide in accordance with ANSI/BHMA A156.3 for mortise locks of lever handles for exit devices. Provide lever handle locks with a breakaway feature (such as a weakened spindle or a shear key) to prevent irreparable damage to the lock when force in excess of that specified in ANSI/BHMA A156.13 is applied to the lever handle. Provide lever handles return to within 1/2 inch of the door face.
SECTION 08 71 00 Page 5
2.2.7 Keys
Furnish one file key, one duplicate key, and one working key for each key change and for each master keying system. Furnish one additional working key for each lock of each keyed-alike group. Furnish construction master keys, and control keys for removable cores. Furnish a quantity of key blanks equal to 20 percent of the total number of file keys. Stamp each key with appropriate key control symbol and "U.S. property - do not duplicate." Do not place room number on keys.
2.2.8 Door Bolts
Provide in accordance with ANSI/BHMA A156.16 . Provide dustproof strikes for bottom bolts, except at doors having metal thresholds.
2.2.9 Closers
Provide in accordance with ANSI/BHMA A156.4 , Series C02000, Grade 1, with PT 4C. Provide with brackets, arms, mounting devices, fasteners, full metal covers and other features necessary for the particular application.
Size closers in accordance with manufacturer's printed recommendations, or provide multi-size closers, Sizes 1 through 6, and list sizes in the Hardware Schedule. Provide manufacturer's 10 year warranty.
Use stainless steel inside bracketed or door mounted closers on exterior doors. On interior doors use closers of 302 or 304 stainless steel or non-ferrous materials.
2.2.9.1 Identification Marking
Engrave each closer with manufacturer's name or trademark, date of manufacture, and manufacturer's size designation in locations that will be visible after installation.
2.2.10 Overhead Holders
Provide in accordance with ANSI/BHMA A156.8 .
2.2.11 Door Protection Plates
Provide in accordance with ANSI/BHMA A156.6 .
2.2.11.1 Sizes of Mop and Kick Plates
2 inch less than door width for single doors; 1 inch less than door width for pairs of doors. Provide 8 inch kick plates for flush doors. Provide 4 inch mop plates.
2.2.12 Door Stops and Silencers
Provide in accordance with ANSI/BHMA A156.16 . Silencers Type L03011.
Provide three silencers for each single door, two for each pair.
2.2.13 Thresholds
Provide in accordance with ANSI/BHMA A156.21 . Use J35100, with vinyl or silicone rubber insert in face of stop, for exterior doors opening out, unless specified otherwise.
SECTION 08 71 00 Page 6
2.2.14 Weatherstripping Gasketing
Provide in accordance with ANSI/BHMA A156.22 . Provide the type and function designation where specified in paragraph HARDWARE SCHEDULE.
Provide a set to include head and jamb seals, sweep strips, and, for pairs of doors, astragals. Air leakage of weatherstripped doors not to exceed
1.25 cubic feet per minute of air per square foot of door area when tested in accordance with ASTM E283. Provide weatherstripping with one of the following:
2.2.14.1 Extruded Aluminum Retainers
Extruded aluminum retainers not less than 0.050 inch wall thickness with vinyl, neoprene, silicone rubber, or polyurethane inserts. Provide clear (natural) anodized aluminum.
2.2.14.2 Interlocking Type
Zinc or bronze not less than 0.018 inch thick.
2.2.14.3 Spring Tension Type
Spring bronze or stainless steel not less than 0.008 inch thick.
2.2.15 Rain Drips
Provide in accordance with ANSI/BHMA A156.22 . Provide extruded aluminum rain drips, not less than 0.08 inch thick, clear anodized finish.
Provide rain drips with a 2 inch overlap on each side of each exterior door that is not protected by an awning, roof, eave or other horizontal projection. Set drips in sealant and fasten with stainless steel screws.
2.2.15.1 Overhead Rain Drips
Approximately 1-1/2 inch high by 2-1/2 inch projection. Align bottom with door frame rabbet.
2.2.16 Auxiliary Hardware (Other than locks)
Provide in accordance with ANSI/BHMA A156.16 , Grade 1.
2.2.17 Special Tools
Provide special tools, such as spanner and socket wrenches and dogging keys, as required to service and adjust hardware items.
2.3 FASTENERS
Provide fasteners of type, quality, size, and quantity appropriate to the specific application. Fastener finish to match hardware. Provide stainless steel or nonferrous metal fasteners in locations exposed to weather. Verify metals in contact with one another are compatible and will avoid galvanic corrosion when exposed to weather.
2.4 FINISHES
Provide in accordance with ANSI/BHMA A156.18 . Provide hardware in BHMA 630 finish (satin stainless steel), unless specified otherwise. Provide
SECTION 08 71 00 Page 7 hinges for exterior doors in stainless steel with BHMA 630 finish.
Furnish exit devices inBHMA 630 finish. Match exposed parts of concealed closers to lock and door trim. Match hardware finish for aluminum doors to the doors.
2.5 KEY CABINET AND CONTROL SYSTEM
Provide in accordance with ANSI/BHMA A156.5 . Type required to yield a capacity (number of hooks) 50 percent greater than the number of key changes used for door locks.
PART 3 EXECUTION
3.1 INSTALLATION
Provide hardware in accordance with manufacturers' printed installation instructions. Fasten hardware to wood surfaces with full-threaded wood screws or sheet metal screws. Provide machine screws set in expansion shields for fastening hardware to solid concrete and masonry surfaces.
Provide toggle bolts where required for fastening to hollow core construction. Provide through bolts where necessary for satisfactory installation.
3.1.1 Weatherstripping Installation
Provide full contact, weathertight seals that allow operation of doors without binding the weatherstripping.
3.1.1.1 Stop Applied Weatherstripping
Fasten in place with color matched sheet metal screws not more than 9 inch on center after doors and frames have been finish painted.
3.1.1.2 Interlocking Type Weatherstripping
Provide interlocking, self adjusting type on heads and jambs and flexible hook type at sills. Nail weatherstripping to door 1 inch on center and to heads and jambs at 4 inch on center.
3.1.1.3 Spring Tension Type Weatherstripping
Provide spring tension type on heads and jambs. Provide bronze nails with bronze. Provide stainless steel nails with stainless steel. Space nails not more than 1-1/2 inch on center.
3.1.2 Threshold Installation
Extend thresholds the full width of the opening and notch end for jamb stops. Set thresholds in a full bed of sealant and anchor to floor with cadmium-plated, countersunk, steel screws in expansion sleeves. For aluminum thresholds placed on top of concrete surfaces, coat the underside surfaces that are in contact with the concrete with fluid applied waterproofing as a separation measure prior to placement.
3.2 HARDWARE LOCATIONS
Provide in accordance with SDI/DOOR A250.8 , unless indicated or specified otherwise.
SECTION 08 71 00 Page 8
a. Kick and Armor Plates: Push side of single-acting doors.
b. Mop Plates: Bottom flush with bottom of door.
3.3 KEY CABINET AND CONTROL SYSTEM
Locate where directed. Tag one set of file keys and one set of duplicate keys. Place other keys in appropriately marked envelopes, or tag each key. Provide complete instructions for setup and use of key control system. On tags and envelopes, indicate door and room numbers or master or grand master key.
3.4 FIELD QUALITY CONTROL
After installation, protect hardware from paint, stains, blemishes, and other damage until acceptance of work. Submit notice of testing 15 days before scheduled, so that testing can be witnessed by the Contracting Officer. Adjust hinges, locks, latches, bolts, holders, closers, and other items to operate properly. Demonstrate that permanent keys operate respective locks, and give keys to the Contracting Officer. Correct, repair, and finish, errors in cutting and fitting and damage to adjoining work.
3.5 HARDWARE SETS
Provide cited hardware items for other doors under this section. Deliver Hardware templates and hardware, except field applied hardware, to the other door and frame manufacturer s for their use in fabricating doors and frames.
3.6 HARDWARE SCHEDULE
Location of Hardware Sets HWS Section 08 11 16, Aluminum Doors & Frames 1-2 Section 08 33 23, Steel Overhead Coiling Doors 3-4 Section 08 71 00, Door Hardware 5-21 Section 10 22 13, Wire Mesh Partitions 22
BB = Ball Bearing; FMC = Full Metal Cover; LHR = Left Hand Reverse; MIL = Mill Finished Aluminum; NRP = Non Removable Pin; RHR = Right Hand Reverse;
SFIC = Small Format Interchangeable Core
HARDWARE SETS
Heavy Duty Exterior Openings
Door No. 129A, 140A, 147A, 148A HWS-5 Exterior Elec/Mech/Tel Com Pair 8 each BB 4.5 x 4.5 Butt Hinge, NRP, A5111 630 2 each Overhead Door Holder, C02511 626 stop mounted slide track arm, push side mount Active Leaf RHR 1 each Lever Storeroom, F86 630 Best 1 each 7 Pin SFIC, F24, E09241 630 1 each Brush Astragal Black Section 08 11 13 1 each Flat Overlapping Astragal Galvanealed Inactive Leaf LHR 2 each 12" Lever Ext Flush Bolt, L14251 626
SECTION 08 71 00 Page 9
1 each Dust Proof Strike, L04021 626 1 each 100" Drip Ledge MIL 1 each 8070 Weatherstrip MIL 2 each 48" Bottom Sweep with Drip MIL 1 each 96" Threshold, J35100 MIL 2 each Floor Stop, L02131 626 Note: Trim is to have an abrasive texture to indicate a potentially hazardous environment to the blind
Door No. 141A, 146A HWS-6 Exterior Elec/Mech/Tel Com 4 each BB 4.5 x 4.5 Butt Hinge, NRP, A5111 630 1 each Overhead Door Holder, C02511 626 stop mounted slide track arm, push side mount 1 each Lever Storeroom, F86 630 Best 1 each 7 Pin SFIC, F24, E09241 630 1 each 52" Drip Ledge MIL 1 each 4070 Weatherstrip MIL 1 each 48" Bottom Sweep with Drip MIL 1 each 48" Threshold, J35100 MIL 1 each Floor Stop, L02131 626 Note: Trim is to have an abrasive texture to indicate a potentially hazardous environment to the blind
Door No. 144A HWS-6A Exterior Elec/Mech/Tel Com 4 each BB 4.5 x 4.5 Butt Hinge, NRP, A5111 630 1 each Overhead Door Holder, C02511 626 stop mounted slide track arm, push side mount 1 each Lever Storeroom, F86 630 Best 1 each 7 Pin SFIC, F24, E09241 630 1 each 52" Drip Ledge MIL 1 each 4070 Weatherstrip MIL 1 each 48" Bottom Sweep with Drip MIL 1 each 48" Threshold, J35100 MIL 1 each Floor Stop, L02131 626 GFGI 1 each DPDT Balanced Magnetic Switch MIL GFGI 1 each Electric Strike 630 GFGI 2 each Card Reader, Wall Mounted Black GFGI 1 each Electric hinge 630
Note: Trim is to have an abrasive texture to indicate a potentially hazardous environment to the blind
Note: Furnish electric metallic tubing raceway, cabling, equipment and programming to support connected devices and operate access control components
Note: Furnish electric metallic tubing raceway, pull strings and blank stainless steel coverplates to receive Government furnished and installed devices
Note: Integrate access control equipment with fire alarm equipment.
Electric strike fails secure upon fire alarm notification
Note: Access control equipment is located in Comm 117
SECTION 08 71 00 Page 10
Door No. 160B HWS-7 Roof Service Entrance 3 each BB 4.5 x 4.5 Butt Hinge, NRP, A5111 630 1 each Overhead Door Holder, C02241 626 track hold and spring stop, stop mounted slide track arm, push side mount 1 each Lever Storeroom, F86 630 Best 1 each 7 Pin SFIC, F24, E09241 630 1 each 40" Drip Ledge MIL 1 each 3070 Weatherstrip MIL 1 each 36" Bottom Sweep with Drip MIL 1 each 36" Threshold, J35100 MIL Note: Trim is to have an abrasive texture to indicate a potentially hazardous environment to the blind
Door No. 128A, 152A HWS-8 Exterior Electrical>800 Amps 4 each BB 4.5 x 4.5 Butt Hinge, NRP, A5111 630 1 each Overhead Door Holder, C02511 626 stop mounted slide track arm, push side mount 1 each Exit Device w/ Lever, EDF03 630 Type 4, B x CD, entry by keyed trim, cylinder dogging function Best 1 each Rim Cylinder Housing, F26 630 Best 1 each 7 Pin SFIC, F24, E09241 630 1 each 52" Drip Ledge MIL 1 each 4070 Weatherstrip MIL 1 each 48" Bottom Sweep with Drip MIL 1 each 48" Threshold, J35100 MIL 1 each Floor Stop, L02131 626 Note: Trim is to have an abrasive texture to indicate a potentially hazardous environment to the blind
Door No. 125A, 125B, 150A HWS-9 Exterior Corridor Entrance 3 each BB 4.5 x 4.5 Butt Hinge, NRP, A5111 630 1 each FMC Closer, C02231 with 630 spring stop, stop mounted slide track arm push side mount 1 each Lever Entry, F109 630 Best 1 each 7 Pin SFIC, F24, E09241 630 1 each 40" Drip Ledge MIL 1 each 3070 Weatherstrip MIL 1 each 36" Bottom Sweep with Drip MIL 1 each 36" Threshold, J35100 MIL 1 each Floor Stop, L02131 626 GFGI 1 each DPDT Balanced Magnetic Switch MIL GFGI 1 each Electric Strike 630 GFGI 2 each Card Reader, Wall Mounted Black GFGI 1 each Electric hinge 630
Note: Furnish electric metallic tubing raceway, cabling, equipment and programming to support connected devices and operate access control components
Note: Furnish electric metallic tubing raceway, pull strings and blank stainless steel coverplates to receive Government furnished and installed devices
SECTION 08 71 00 Page 11
Note: Integrate access control equipment with fire alarm equipment.
Electric strike fails secure upon fire alarm notification
Note: Access control equipment is located in Comm 117
Door No. 120B, 122A, 127B HWS-10 Exterior Shop 3 each BB 4.5 x 4.5 Butt Hinge, NRP, A5111 630 1 each FMC Closer, C02241 with 630 track hold and spring stop, stop mounted slide track arm, push side mount 1 each Lever Storeroom, F86 630 Best 1 each 7 Pin SFIC, F24, E09241 630 1 each 40" Drip Ledge MIL 1 each 3070 Weatherstrip MIL 1 each 36" Bottom Sweep with Drip MIL 1 each 36" Threshold, J35100 MIL 1 each Floor Stop, L02131 626 GFGI 1 each DPDT Balanced Magnetic Switch MIL GFGI 1 each Electric Strike 630 GFGI 2 each Card Reader, Wall Mounted Black GFGI 1 each Electric hinge 630
Note: Furnish electric metallic tubing raceway, cabling, equipment and programming to support connected devices and operate access control components
Note: Furnish electric metallic tubing raceway, pull strings and blank stainless steel coverplates to receive Government furnished and installed devices
Note: Integrate access control equipment with fire alarm equipment.
Electric strike fails secure upon fire alarm notification
Note: Access control equipment is located in Comm 117
Door No. 131B, 131C, 135B, 136C, 151A, 155B HWS-10A Exterior Shop 3 each BB 4.5 x 4.5 Butt Hinge, NRP, A5111 630 1 each FMC Closer, C02241 with 630 track hold and spring stop, stop mounted slide track arm, push side mount 1 each Lever Storeroom, F86 630 Best 1 each 7 Pin SFIC, F24, E09241 630 1 each 40" Drip Ledge MIL 1 each 3070 Weatherstrip MIL 1 each 36" Bottom Sweep with Drip MIL 1 each 36" Threshold, J35100 MIL 1 each Floor Stop, L02131 626 GFGI 1 each DPDT Balanced Magnetic Switch MIL GFGI 1 each Electric hinge 630
Note: Furnish electric metallic tubing raceway, cabling, equipment and programming to support connected devices and operate access control components
Note: Furnish electric metallic tubing raceway, pull strings and blank stainless steel coverplates to receive Government furnished and installed
SECTION 08 71 00 Page 12 devices
Note: Integrate access control equipment with fire alarm equipment.
Electric strike fails secure upon fire alarm notification
Note: Access control equipment is located in Comm 117
Heavy Duty Non Rated Openings
Door No. 134A, 138A HWS-11 Storage Pair 6 each BB 4.5 x 4.5 Butt Hinge, A5111 630 Active Leaf RHR 1 each Lever Storeroom, F86 630 Best 1 each 7 Pin SFIC, F24, E09241 630 Inactive Leaf LHR 2 each 12" Lever Ext Flush Bolt, L14251 626 1 each Dust Proof Strike, L04021 626 2 each 8 x 34 Beveled Kick Plate, J102 630 2 each Silencer, L03011 Grey 2 each Wall Stop, L02251 or 626 Floor Stop, L02161
Door No. 158A, 160A HWS-12 Elec/Mech/Tel Com 3 each BB 4.5 x 4.5 Butt Hinge, A5111 630 1 each Overhead Door Holder, C02511 626 stop mounted slide track arm, push side mount 1 each Lever Storeroom, F86 630 Best 1 each 7 Pin SFIC, F24, E09241 630 3 each Silencer, L03011 Grey 1 each Wall Stop, L02251 or 626 Floor Stop, L02161 Note: Trim is to have an abrasive texture to indicate a potentially hazardous environment to the blind
Door No. 117A HWS-12A Elec/Mech/Tel Com 3 each BB 4.5 x 4.5 Butt Hinge, A5111 630 1 each Overhead Door Holder, C02511 626 stop mounted slide track arm, push side mount 1 each Lever Storeroom, F86 630 Best 1 each 7 Pin SFIC, F24, E09241 630 3 each Silencer, L03011 Grey 1 each Wall Stop, L02251 or 626 Floor Stop, L02161 GFGI 1 each DPDT Balanced Magnetic Switch MIL GFGI 1 each Electric Strike 630 GFGI 2 each Card Reader, Wall Mounted Black GFGI 1 each Electric hinge 630
Note: Trim is to have an abrasive texture to indicate a potentially hazardous environment to the blind
Note: Furnish electric metallic tubing raceway, cabling, equipment and programming to support connected devices and operate access control components
SECTION 08 71 00 Page 13
Note: Furnish electric metallic tubing raceway, pull strings and blank stainless steel coverplates to receive Government furnished and installed devices
Note: Integrate access control equipment with fire alarm equipment.
Electric strike fails secure upon fire alarm notification
Note: Access control equipment is located in Comm 117
Door No. 102A, 104A, 104B, 107A, 107B, 108A, 109A, 110A, 110B, 113A, 113B, 115A HWS-13 Gang Head, Shower 3 each BB 4.5 x 4.5 Butt Hinge, A5111 630 1 each FMC Closer, C02021 630 1 each Strike Filler Plate 600 1 each 4 x 16 Beveled Push Plate, J301 630 1 each 4 x 16 Beveled Pull Plate, J405 630 1 each 8 x 34 Beveled Kick Plate, J102 630 1 each 4 x 34 Beveled Mop Plate, J103 630 3 each Silencer, L03011 Grey 1 each Wall Stop, L02251 or 626 Floor Stop, L02161
Door No. 105A, 112A HWS-14 Staff Head 3 each BB 4.5 x 4.5 Butt Hinge, A5111 630 1 each FMC Closer, C02021 630 1 each Lever Privacy, F76 630 no SFIC 1 each 8 x 34 Beveled Kick Plate, J102 630 1 each 4 x 34 Beveled Mop Plate, J103 630 3 each Silencer, L03011 Grey 1 each Wall Stop, L02251 or 626 Floor Stop, L02161
Door No. 116A HWS-15 Janitor, Utility 3 each BB 4.5 x 4.5 Butt Hinge, A5111 630 1 each FMC Closer, C02021 630 1 each Lever Storeroom, F86 630 Best 1 each 7 Pin SFIC, F24, E09241 630 1 each 8 x 34 Beveled Kick Plate, J102 630 1 each 4 x 34 Beveled Mop Plate, J103 630 3 each Silencer, L03011 Grey 1 each Wall Stop, L02251 or 626 Floor Stop, L02161 1 each Lever Door Holder, L01381 626 Note: Trim is to have an abrasive texture to indicate a potentially hazardous environment to the blind
Door No. 157A HWS-16 Wellness, Lactation 3 each BB 4.5 x 4.5 Butt Hinge, A5111 630 1 each FMC Closer, C02021 630 1 each Lever Privacy, F76 630 no SFIC 3 each Silencer, L03011 Grey 1 each Wall Stop, L02251 or 626
SECTION 08 71 00 Page 14
Floor Stop, L02161
Door No. 120A, 121A, 122B, 127A, 131A, 139A, 153A HWS-17 Suite, Shop, Training 3 each BB 4.5 x 4.5 Butt Hinge, A5111 630 1 each FMC Closer, C02231 with 630 track hold open, soffit mounted slide track arm, push side mount 1 each Lever Entry, F109 630 Best 1 each 7 Pin SFIC, F24, E09241 630 3 each Silencer, L03011 Grey 1 each Wall Stop, L02251 or 626 Floor Stop, L02161
Door No. 135A, 135D, 136A, 155A HWS-17.1 Clean Spaces 3 each BB 4.5 x 4.5 Butt Hinge, A5111 630 1 each FMC Closer, C02231 with 630 track hold open, soffit mounted slide track arm, push side mount 1 each Lever Entry, F109 630 Best 1 each 7 Pin SFIC, F24, E09241 630 1 each 3070 Weatherstrip MIL 1 each Wall Stop, L02251 or 626 Floor Stop, L02161
Door No. 167A, 168A, 169A HWS-18 Suite, Office 3 each BB 4.5 x 4.5 Butt Hinge, A5111 630 1 each Lever Entry, F109 630 Best 1 each 7 Pin SFIC, F24, E09241 630 3 each Silencer, L03011 Grey 1 each Wall Stop, L02251 or 626 Floor Stop, L02161
Door No. 164A, 164B, 165A HWS-19 Training, Conference 3 each BB 4.5 x 4.5 Butt Hinge, A5111 630 1 each Lever Passage, F75 630 no SFIC 3 each Silencer, L03011 Grey 1 each Wall Stop, L02251 or 626 Floor Stop, L02161
Door No. 162A, 162B HWS-20 Suite, Lounge, Break Room 3 each BB 4.5 x 4.5 Butt Hinge, A5111 630 1 each FMC Closer, C02021 630 1 each Dead Bolt, E0141 630 Best 1 each 7 Pin SFIC, F24, E09241 630 1 each Strike Filler Plate 600 1 each 6 inch, Type 7, Back to Back 630 Pulls, J401 2 each 4 x 16 Beveled Push Plate, J301 630 1 each 8 x 34 Beveled Kick Plate, J102 630 3 each Silencer, L03011 Grey 1 each Wall Stop, L02251 or 626 Floor Stop, L02161
SECTION 08 71 00 Page 15
Door No. 120D, 120E, 120F, 120G HWS-21 Access Door 2 each BB 4.5 x 4.5 Butt Hinge, A5111 630 1 each Lever Passage, F75 630 no SFIC 2 each Silencer, L03011 Grey 1 each Wall Stop, L02251 626
-- End of Section --
SECTION 08 71 00 Page 16
| 08 71 00 - DOOR HARDWARE |
| PART 1 GENERAL |
| 1.1 REFERENCES |
| 1.2 SUBMITTALS |
| 1.3 SHOP DRAWINGS |
| 1.4 PRODUCT DATA |
| 1.5 HARDWARE SCHEDULE |
| 1.5.1 Hardware Item List: |
| 1.5.2 Hardware Schedule |
| 1.6 KEY BITTING CHART REQUIREMENTS |
| 1.6.1 Requirements |
| 1.7 QUALITY ASSURANCE |
| 1.7.1 Hardware Manufacturers and Modifications |
| 1.7.2 Key Shop Drawings Coordination Meeting |
1.8 DELIVERY, STORAGE, AND HANDLING
| PART 2 PRODUCTS |
| 2.1 TEMPLATE HARDWARE |
| 2.2 HARDWARE ITEMS |
| 2.2.1 Hinges |
| 2.2.2 Locks and Latches |
| 2.2.2.1 Bored Locks and Latches |
| 2.2.2.2 Auxiliary Locks |
| 2.2.3 Exit Devices |
| 2.2.4 Cylinders and Cores |
| 2.2.5 Keying System |
| 2.2.6 Lock Trim |
| 2.2.6.1 Lever Handles |
| 2.2.7 Keys |
| 2.2.8 Door Bolts |
| 2.2.9 Closers |
| 2.2.9.1 Identification Marking |
| 2.2.10 Overhead Holders |
| 2.2.11 Door Protection Plates |
| 2.2.11.1 Sizes of Mop and Kick Plates |
| 2.2.12 Door Stops and Silencers |
| 2.2.13 Thresholds |
| 2.2.14 Weatherstripping Gasketing |
| 2.2.14.1 Extruded Aluminum Retainers |
| 2.2.14.2 Interlocking Type |
| 2.2.14.3 Spring Tension Type |
| 2.2.15 Rain Drips |
| 2.2.15.1 Overhead Rain Drips |
| 2.2.16 Auxiliary Hardware Other than locks |
| 2.2.17 Special Tools |
| 2.3 FASTENERS |
| 2.4 FINISHES |
| 2.5 KEY CABINET AND CONTROL SYSTEM |
| PART 3 EXECUTION |
| 3.1 INSTALLATION |
| 3.1.1 Weatherstripping Installation |
| 3.1.1.1 Stop Applied Weatherstripping |
| 3.1.1.2 Interlocking Type Weatherstripping |
| 3.1.1.3 Spring Tension Type Weatherstripping |
3.1.2 Threshold Installation
| 3.2 HARDWARE LOCATIONS |
| 3.3 KEY CABINET AND CONTROL SYSTEM |
| 3.4 FIELD QUALITY CONTROL |
| 3.5 HARDWARE SETS |
| 3.6 HARDWARE SCHEDULE |
File details come from the government source that posted it. Updated .