This pre-solicitation notice seeks proposals for the production of hardware in support of the AN/SPQ-15(V) MK 6 MOD 1 Data Distribution System programs. The contract will have a five-year period of performance starting in November 2022 and will provide standard data and distribution systems, switchboards, decoders, converters, switches and upgrades. The solicitation number is N0017822R2501 and will be available on March 7, 2022 for 30 days on SAM.gov. The contract type will include firm-fixed-price CLINs for hardware production, cost-plus-fixed-fee CLINs for software life cycle support and software engineering development. An organizational conflict of interest clause will be included. The requirement is designated as a small business set-aside and proposals will be evaluated using best value procedures. Award is planned for November 2022.
View the file
Other files for this federal contract opportunity
Show all 40
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
455088F
SHAPE
REVISIONS
| REV |
| DESCRIPTION |
| DATE |
| APPROVED |
| A |
| Incorporated changes per CO # 24-2284 |
| 4/20/10 |
| PDC |
| B |
| Incorporated changes per CO # 24-2782 |
| 1-18-11 |
| AW |
| C |
| Incorporated changes per CO # 24-3310 |
| 12/9/2011 |
| AW |
| D |
| Incorporated changes per CO # 24-3448 |
| 5/30/2012 |
| PDC |
| E |
| Incorporated changes per CO # 24-3490 |
| 8/8/2012 |
| PDC |
| F |
| Incorporated changes per CO # 24-3508 |
| 9/17/2012 |
| PDC |
| ORIGINAL DATE 27 MARCH 2009 |
| DATE APPROVED |
| FRONTIER ELECTRONIC SYS. |
STILLWATER, OKLAHOMA 74076-1023
| ORIGINATOR |
| TED NISHIMUTA |
| 30 MAR 2009 |
| DOC. COORDINATOR |
| KELLY WHITFIELD |
| 3-30-09 |
| ACCEPTANCE TEST PROCEDURE |
FOR THE MEDIA CONVERTER
MODULE (MC)
(P/N 456170)
| PROJECT ENGINEER |
| ROCKY SUTTON |
| 20 MAR 2009 |
| PROGRAM MGR. |
| CHRISTOPHER JOBE |
| 30 MAR 2009 |
| QUALITY |
| MICHAEL S. WEBSTER |
| 3/30/09 |
CODE IDENT.
63812 455088F
ACCEPTANCE TEST PROCEDURE
FOR THE MEDIA CONVERTER
MODULE (MC)
(P/N 456170)
TABLE OF CONTENTS
Section Title Page
GENERAL INFORMATION
1.1
SCOPE
1.2
PURPOSE
1.3
TEST EQUIPMENT
1.4
LRADDS TEST RACK
1.5
GENERAL REQUIREMENTS
1.5.1 Production Routers
1.5.2 Test Conditions
1.5.3 Failure Reporting
1.5.4 Test Files
1.5.5 Test Data
PRE-TEST EVALUATION
2.1
CONTINUITY TEST
2.2
INSTALLATION AND SETUP PROCEDURE
2.2.1 Ethernet Fiber Cable Installation 2.2.2 Program the Module 2.3
AUTOMATED TEST PROGRAM
BURN-IN
FINAL TEST
4.1
AUTOMATED TEST PROGRAM
TABLE OF CONTENTS (Continued)
Section Title Page
APPENDIX A
PRODUCTION ROUTERS
A-1
APPENDIX B
NON-CONFORMANCE REPORTS (NCRs) B-1
APPENDIX C
BURN-IN LOG
C-1
LIST OF FIGURES
Figure Title Page
1.1-1 Testing Flow
1.4-1 Functional Test Setup
2.2.1-1 Ethernet Fiber Cable Assembly Installation
LIST OF TABLES
Table Title Page
1.3-1 Test Equipment
1.5.4-1 Test Files
2.1-1 Short Test Table
2.2-1 DIM Switch Settings for 456063-1 2.2-2 DIM Switch Settings for 456357-1 2.2-3 RIM Switch Settings for 456005-1 or 456354-1 2.2-4 Media Converter Switch Settings for 456170-1 Program Mode 2.2.2-1 Media Converter Module (MC) Switch Settings
2.3-1 Pre-Test Verification Table 3-1 Burn-in Test Information 4.1-1 Final Test Verification Table
SECTION 1
GENERAL INFORMATION
1.1
SCOPE
This document contains the test requirements for the acceptance testing of the Media Converter Module (MC) (P/N 456170). This document contains the following sections:
Section 1: General Information
Section 2: Pre-Test Evaluation Procedures
Section 3: Burn-In Procedures
Section 4: Final Test Procedures
The figure below illustrates the order of testing.
SHAPE
Figure 1.1-1. Testing Flow
1.2
PURPOSE
The purpose of this document is to demonstrate that the Media Converter Module (MC), as manufactured by Frontier Electronic Systems, meets or exceeds all requirements identified within this document.
1.3
TEST EQUIPMENT
Table 1.3-1 lists the equipment required to perform the procedures contained in this document. Enter the serial number and calibration expiration date for each piece of test equipment.
Table 1.3-1. Test Equipment
| DESCRIPTION |
| USE |
| MODEL |
| SERIAL NUMBER |
| MANUFACTURER/ |
SPECIFICATIONS
CALIBRATION
EXP. DATE
| LRADDS Tester |
| Automated Test |
| 456124-1 |
| N/A |
| FES |
| N/A |
| Digital Multimeter |
| Voltage Measurement |
| 87 |
Fluke
Note 1: FES maintains calibration of equipment IAW ISO 9001, procedures FES-QSP-7.6-1-1 and FES-QSP-7.6-2.
Note 2: Equivalent or superior equipment may be substituted for the equipment listed above.
1.4 LRADDS Test rack
Figure 1.4-1 illustrates the equipment required to perform the procedures contained in this document.
Figure 1.4-1. Functional Test Setup
1.5
GENERAL REQUIREMENTS
1.5.1 Production Routers
Insert the Production Routers for the module into Appendix A.
1.5.2 Test Conditions
Unless otherwise specified herein, testing shall be performed at standard room ambient temperature, 60 to 80F.
1.5.3 Failure Reporting
Non-Conformance Reports (NCRs) shall be used to document test failures in accordance with FES-QSP-8.3-3 when required. A copy of the NCR shall be included under Appendix B.
1.5.4 Test Files
The test files required for testing are shown in the table below. A controlled copy of the MCM script file resides in Document Control under Mstr_software\456271\ -01 Rev X\ (where X is the latest revision).
Table 1.5.4-1. Test Files
| TEST FILE NAME |
| PURPOSE |
| MCM-001 |
| Discrete Azimuth - T/R Conversion Test |
1.5.5 Test Data
Successful completion of each test shall be annotated within these procedures.
SECTION 2
PRE-TEST EVALUATION
This section contains the steps for conducting a preliminary test of the Media Converter Module (MC) before subjecting it to a burn-in cycle.
2.1
CONTINUITY TEST
Using a digital multi-meter (DMM), verify that the power planes are not shorted together or to ground. Refer to schematic drawing 456168 to locate measuring points.
1.
Verify that there is no short between the following points, where a short is less than 5 Ohms. Measure points for a maximum duration of 5 seconds. Test points TP1 through TP6 are GND.
Table 2.1-1. Short Test Table
GND
TP1–6
+1.2V R66 +2.5V
R67 +3.3V R68
+1.2V R66
+2.5V R67
+3.3
R68
+5V C1
VERIFIED: _____________
2.2
INSTALLATION AND SETUP PROCEDURE
The installation and setup procedure verifies the test configuration.
1. Set the Test Chassis’ Power Supply Module switch to the OFF position.
2. Configure the switches on the Media Converter Module (MC) (P/N 456170) as shown on the label of the module and then reinstall the module into the Test Fixture securing the fasteners.
3.
Install the Media Converter Module (MC) into slot labeled as MC of the CRC Test Chassis in the LRADDS Test Rack (456124).
3. Loosen fasteners and remove Display Interface Module (DIM slot2) from the Display Interface Unit (DIU) Module Test Chassis. Verify the following switch settings as shown in Table 2.2-1 or Table 2.2-2 depending on assembly number used and reinstall module.
Table 2.2-1. DIM Switch Settings for 456063-1
SWITCH
3 WIRE OUTPUT 8192
| S1-1 |
| Display Select |
| SPA/Q70 |
S1-2
Display Type
S1-3
S1-4
Azimuth Rate
S1-5
S1-6
Primary/Secondary
S1-7
Video SIM
S1-8
AZ True/Relative
| S4-1 |
| IP Host Address |
| 1 |
S4-2
| 2 |
| ON |
S4-3
| 4 |
| ON |
S4-4
S4-5
| 16 |
| ON |
S4-6
Table 2.2-1. DIM Switch Settings for 456063-1 (Continued)
SWITCH
3 WIRE OUTPUT 8192
S4-7
| 64 |
| ON |
S4-8
| 128 |
| ON |
| S5-1 |
| Power Delay |
S5-2
ON
S5-3
ON
S5-4
S11
SIM
S16
Local Select
S17
| Video Select |
| 0 |
S18
| Radar Select |
| 1 |
| S19-1 |
| Data |
ON
S19-2
ON
S19-3
ON
S19-4
ON
Table 2.2-2. DIM Switch Settings for 456357-1
SWITCH
3 WIRE OUTPUT 8192
| S1-1 |
| Display Select |
| SPA/Q70 |
S1-2
Display Type
S1-3
S1-4
Azimuth Rate
S1-5
S1-6
Primary/Secondary
S1-7
Video SIM
S1-8
AZ True/Relative
| S2-1 |
| Timeout |
| 1 |
| ON |
S2-2
S2-3
S2-4
| S3-1 |
| IP Host Address |
| 1 |
S3-2
| 2 |
| ON |
S3-3
| 4 |
| ON |
S3-4
S3-5
| 16 |
| ON |
Table 2.2-2. DIM Switch Settings for 456357-1 (Continued)
SWITCH
3 WIRE OUTPUT 8192
S3-6
S3-7
| 64 |
| ON |
S3-8
| 128 |
| ON |
| S4-1 |
| Data |
ON
S4-2
ON
S4-3
ON
S4-4
ON
| S9-1 |
| Power Delay |
S9-2
ON
S9-3
ON
S9-4
S10
SIM
S11
Local Select
S12
| Video Select |
| 0 |
S13
| Radar Select |
| 1 |
*Closed = ON; Open/Blank = OFF 5.
Loosen fasteners and remove Radar Interface Module (RIM slot2) from the Radar Interface Unit (RIU) Module Test Chassis. Verify the following switch settings as shown in Table 2.2-3 and reinstall module securing fasteners.
Table 2.2-3. RIM Switch Settings for 456005-1 or 456354-1
SWITCH
PPI/RHI INPUT 8192
| S1-1 |
| Radar Select |
| Azimuth Rate |
S1-2
S1-3
| Radar Select |
| ON |
S1-4
ON
S1-5
| TBI Use/over ride |
| ON |
S1-6
AZ True/Relative
S1-7
Not used
S1-8
Not used
Table 2.2-3. RIM Switch Settings for 456005-1 or 456354-1 (Continued)
SWITCH
PPI/RHI INPUT 8192
| S2-1 |
| Input Select |
| TE SPLT |
S2-2
| TE |
| ON |
S2-3
EOS
S2-4
TM SPLT
S2-5
| TM |
| ON |
S2-6
RM
S2-7
VID 1 SPLT
S2-8
VID 1
| S3-1 |
| Input Select |
| ARP SPLT |
S3-2
ARP
S3-3
DY
S3-4
ACP SPLT
S3-5
ACP
S3-6
DX
S3-7
VID 2 SPLT
S3-8
VID 2
*Closed = ON; Open/Blank = OFF
Table 2.2-4. Media Converter Switch Settings for 456170-1 Program Mode
SWITCH
MC SETTING
| S1-1, S3-1 |
| Config (0) |
| S1-2, S3-2 |
| Config (1) |
| S1-3, S3-3 |
| Config (2) |
| S1-4, S3-4 |
| SLL |
| S1-5, S3-5 |
| SDA |
| S1-6, S3-6 |
| Normal |
| ON |
| S1-7, S3-7 |
| Reset |
| S1-8, S3-8 |
| Power Down |
| S2-1, S4-1 |
| Config (5) |
| S2-2, S4-2 |
| Config (5) |
| ON |
| S2-3, S4-3 |
| Config (5) |
| S2-4, S4-4 |
| Config (5) |
2.2.1 Ethernet Fiber Cable Installation
This section describes where to attach the external Ethernet Fiber Cable Assemblies.
1. Install the following cable assemblies according to Figure 2.2.1-1.
Figure 2.2.1-1. Ethernet Fiber Cable Assembly Installation
2.2.2 Program the Module
Note: The Aardvark user interface software can be found at 456272.
1. Plug in the Aardvark programming cable into J3. Place the board into the VME chassis and apply power to the board.
2. Open the Aardvark programming software.
3. Click on Configure Aardvark Adapter.
4. Click Refresh List. Select Port 0 and Batch Mode and click OK
5. Click Load and navigate to the following location:
Data3:\Document Control\Mstr_software\456187\-01 RevX\ (where X is the Rev)
6. Select the 456187 xml file and click Open
7. Click on Execute.
8. The program will load the xml file and show a Stopped status when complete.
9. Turn off power to the VME chassis and remove the board. Move the Aardvark programming cable from J3 to J4 and repeat the process in this document for the second part of the Media Converter board.
10. The module is now programmed with firmware and software. Turn off power to the VME chassis and refer to the ATP for the next steps.
11. Record below the firmware and software revisions used.
456187 Rev:_____________
12. Verify that the firmware and software have been loaded without failures.
13. Create and apply the label for Part Numbers flashed per Assembly Drawing 456170-1. Verify below
14. Set the Test Chassis’ Power Supply Module switch to the OFF position.
15. Remove the Media Converter Module (MC) (P/N 456170) and configure the switches as shown in Table 2.2.2-1.
Table 2.2.2-1. Media Converter Module (MC) Switch Settings
SWITCH
MC SETTING
| S1-1, S3-1 |
| Config (0) |
| S1-2, S3-2 |
| Config (1) |
| S1-3, S3-3 |
| Config (2) |
| S1-4, S3-4 |
| SLL |
| ON |
| S1-5, S3-5 |
| SDA |
| ON |
| S1-6, S3-6 |
| Normal |
| ON |
| S1-7, S3-7 |
| Reset |
Table 2.2.2-1. Media Converter Module (MC) Switch Settings (Continued)
SWITCH
MC SETTING
| S1-8, S3-8 |
| Power Down |
| S2-1, S4-1 |
| Config (5) |
| S2-2, S4-2 |
| Config (5) |
| ON |
| S2-3, S4-3 |
| Config (5) |
| S2-4, S4-4 |
| Config (5) |
16. Reinstall the Media Converter Module into the Test Fixture, securing the fasteners.
2.3
AUTOMATED TEST PROGRAM
These procedures are performed using the LRADDS Test Rack and computer.
1.
Set the IIU Module Test Chassis’ Power Supply Module switch to the ON position. Also turn ON LRADDS computer tester power.
2.
Select the LRADDS Automated Tester icon on the initial windows screen and follow the displayed instructions.
3.
A dialog box “Interface Configurations” appears showing the expected Comm Port Assignments.
a.
Verify that the Communication Ports and GPIB Address are set as they appear in the display.
b.
Select OK when complete.
4.
Select Test Info.
A dialog box prompting for “Tester Identification” will now be displayed. Enter the test operator's ID and press ENTER from the key module.
6.
A dialog box appears requesting a Serial Number. Enter the Media Converter (MC) Serial Number and press ENTER.
7.
Select test type “Module Level Testing” and then “Preliminary”.
8.
At the Module Selection screen, select “Media Converter (456170-1)”.
9.
For Script files in Table 2.3-1 the DIM needs to be in slot 2 of the DIU and the RIM needs to be in slot 2 of the RIU.
10.
From the displayed Main Screen Menu, select the LOAD TEST option. A dialog box with the names of the tests that can be run will be displayed.
11.
Select all scripts in Table 2.3-1.
12.
The Main Screen will be displayed showing the entered information. From this display, select the BEGIN TEST option. The program will now display dialog boxes to provide the operator with step-by-step instructions for completing the test. Upon completion of each test, annotate the appropriate entry in Table 2.3-1.
Table 2.3-1. Pre-Test Verification Table
| Script File Name |
| Test |
| Estimated Run Time |
| Complete |
| MCM-001 |
| Discrete Azimuth - T/R Conversion Test |
| 5 Minutes |
NOTES
To re-run any test, execute step 11.
13.
After the test is complete, select Close File from the menu to save the test data.
14.
Set the IIU Module Test Chassis’ Power Supply Module switch to the OFF position.
SECTION 3
BURN-IN
This section contains the procedures to be followed to accomplish a burn-in cycle on the Media Converter Module (MC).
1.
Place the Media Converter Module (MC) into a test bed capable of providing power to the module per VMEbus standards.
2.
Place the test bed into a thermal chamber.
3.
Complete a 48 hour (minimum) burn-in cycle at 45°C ± 5°C with power applied to the module.
4.
In Table 3-1 record the time and date of the beginning and end of the cycle and the total burn-in time.
Table 3-1. Burn-in Test Information
| Start |
| Stop |
| Total Burn-in Time |
Date/Time
Insert the temperature burn-in chart into Appendix C.
Completion Verified: ________________
SECTION 4
FINAL TEST
This section details the functional testing of the Media Converter Module (MC).
4.1
AUTOMATED TEST PROGRAM
These procedures are performed using the LRADDS Test Rack and computer.
1.
Connect all cable per Figure 2.2.1-1
2.
Set the IIU Module Test Chassis’ Power Supply Module switch to the ON position. Also turn ON LRADDS computer tester power.
3.
Flash the Media Converter under test with firmware number 456187. Steps to flash are located in the 456187 folder. There are two flashes per board. Folders are located in Data3\Document Control\Mstr_software\NUMBER
4.
Select the LRADDS Automated Tester icon on the initial windows screen and follow the displayed instructions.
5.
A dialog box “Interface Configurations” appears showing the expected Comm Port Assignments.
a.
Verify that the Communication Ports and GPIB Address are set as they appear in the display.
b.
Select OK when complete.
6.
Select Test Info.
7.
A dialog box prompting for “Tester Identification” will now be displayed. Enter the test operator's ID and press ENTER from the key module.
8.
A dialog box appears requesting a Serial Number. Enter the Media Converter (MC) Serial Number and press ENTER.
9.
Select test type “Module Level Testing” and then “Final”.
10.
At the Module Selection screen, select “Media Converter (456170-1)”.
11.
For Script files in Table 4.1-1 the DIM needs to be in slot 2 of the DIU and the RIM needs to be in slot 2 of the RIU.
12.
From the displayed Main Screen Menu, select the LOAD TEST option. A dialog box with the names of the tests that can be run will be displayed.
13.
Select all scripts in Table 4.1-1.
14.
The Main Screen will be displayed showing the entered information. From this display, select the BEGIN TEST option. The program will now display dialog boxes to provide the operator with step-by-step instructions for completing the test. Upon completion of each test, annotate the appropriate entry in Table 4.1-1.
Table 4.1-1. Final Test Verification Table
| Script File Name |
| Test |
| Estimated Run Time |
| Complete |
| MCM-001 |
| Discrete Azimuth - T/R Conversion Test |
| 5 Minutes |
NOTES
To re-run any test, execute step 12.
15.
After the test is complete, select Close File from the menu to save the test data.
16.
Set the IIU Module Test Chassis’ Power Supply Module switch to the OFF position.
17.
Transfer data files to the network drive data3\Shared Data\Naval Systems\Test Data\part number\serial number.
Comments:
Validation
This sheet is supplied as a validation of the completion and accuracy of the data contained herein. The Test Technician will sign and date as an indication that all instructions have been followed and that each test step has been successfully completed. Signature by the Quality Engineer is an acknowledgement that the test data has been reviewed for completion and accuracy. The applicable test or inspection stamp will be affixed by the signature blocks
Test Technician: ________________________________Date:____________
Quality Engineer: _______________________________Date:____________
APPENDIX A
PRODUCTION ROUTERS
APPENDIX B
NON-CONFORMANCE REPORTS (NCRs)
APPENDIX C
BURN-IN LOG
ACCEPTANCE TEST PROCEDURE
FOR THE MEDIA CONVERTER
MODULE (MC)
(P/N 456170-1)
S/N: _________________
Prepared For:
Naval Surface Warfare Center Dam Neck (NSWCDN)
Dahlgren Division, Code F31
1922 Regulus Avenue
Virginia Beach, VA 23461-2067
17 SEPTEMBER 2012
DISTRIBUTION STATEMENT D: Distribution authorized to the Department of Defense and U.S. DoD contractors only due to protecting technical, operational, or operational use information from automatic dissemination under the International Exchange Program or by other means as determined on or after date of task order award. Other requests for this document shall be referred to NAVSEA CDSA Code F31.
WARNING – This document contains technical data whose export is restricted by the Arms Export Control Act (Title 22, U.S.C., Sec 2751, et seq.) or the Export Administration Act of 1979, as amended, Title 50, U.S.C., App. 2401 et seq. Violations of these export laws are subject to severe criminal penalties. Disseminate in accordance with provisions of DoD Directive 5230.25.
Prepared By:
FRONTIER ELECTRONIC SYSTEMS CORP.
P.O. BOX 1023
STILLWATER, OKLAHOMA 74076-1023
YES
NO
NO
YES
Pre-test Evaluation
FINAL TEST
START MODULE TEST
INSTALLATION AND SETUP
SECTION 2.1
AUTOMATED TEST PROGRAM SECTION 2.2
SECTION 2.2
Pass Test?
BURN-IN
BOARD
SECTION 3
INSTALLATION
AND SETUP
SECTION 2.1
AUTOMATED
TEST PROGRAM
SECTION 4.1
Pass Test?
Module Test complete
REPAIR
BOARD PER
PARA 1.4.3
MODULE TEST
_1409380750.vsd text
Interface Panel RIU
LRADDS Test Fixture
SPY 6 Wire HRI
Sin/Cos
Synchro
ACP/ARP
SPY 6-Wire PPI
Azimuth Radar Data
NW Sw (up to 4)
NW Sw (up to 4)
Protocol Analyzer H/W and SW (LEDA Plus)
3-Wire
Backplane
Power Supply
RIM (Golden)
RADDS
ACP/ARP
Synchro
RIM (Slot 2)
RIM (Slot 3)
RIM (Slot 4)
Interface Panel DIU
DIM (Golden)
DIM (Slot 2)
DIM (Slot 3)
DIM (Slot 4)
SpySSM
SSM
Interface Panel IIU
IIM (Slot 1)
IIM (Slot 2)
IIM (Slot 3)
IIM (Slot 4)
RIM Test Chassis (RIU)
DIM Test Chassis (DIU)
IIM Test Chassis (IIU)
IIM (Slot 5)
IIM (Slot 6)
IIM (Slot 7)
QSDM (Slot 8)
MC (Slot 9)
LRADDS Test System
NW Sw
NW Sw (up to 14)
NAWCAD SIM
Video
Big Iron 24 port Network Switch
Dual Scan Cvtr Comupter
Dual Scan Cvtr Comptuer
HMI Computer w/RS422 conv
Power Conditioner
2 -T
To RIU Lx (up to 4)
To DIU Lx (up to 4)
To IIU Lx (up to 14)
To CDS Lx (up to 13)
CDS Emulator
Lx (1)
Test Computer (Dell T7400 w/ 3 ea Intel EXPI9404PTL Quad Port NIC)
Fiber Jumper
To Port Under test
Serial Data (2)
Copper Jumper
NAV Data (RS-422)
Test System Configured For Media Converter Test
IFF Vid (2)
SBC (Slot 10)
456115-1
RIM (Golden)
RIM (Slot 1)
DIM (Slot 1)
DIM (Golden)
_1399880234.vsd