Roybal_DB_RFP_Amendment_04_9th_Fl_Room_Reqs.pdf

PDF 799 KB Posted

Attached to
Edward R. Roybal Repair and Alteration Tenant Improvement Prospectus Project
Solicitation number
GS-09P-15-KT-C-0014
Issued by

About this file

9th Fl Room Requirements

View the file

Other files

File Type Posted
Roybal_DB_RFP_Amendment_06.pdf PDF
Roybal_DB_RFP_Amendment_05.pdf PDF
Roybal_DB_RFP_Amendment_04.pdf PDF
Roybal_DB_RFP_Amendment_04_14th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_6th_FL_room_reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_revised_bid_sheet.pdf PDF
Roybal_DB_RFP_Amendment_04_scope_reductions.pdf PDF
Roybal_DB_RFP_Amendment_04_16th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_8th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_15th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_10th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_7th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Certificate_of_Current_Cost_or_Pricing_Data_(1).pdf PDF
Roybal_DB_RFP_Amendment_03_SF30.pdf PDF
Roybal_DB_bid_sheet_Amendment_03.pdf PDF
Roybal_DB_RFP_PPQ_Amendment_02.docx DOCX document
Roybal_DB_bid_sheet_Amendment_02.pdf PDF
Roybal_DB_RFP_Offeror_Representations_and_Certifications.doc DOC document
Roybal_DB_RFP_Amendment_02_SF30.pdf PDF
Roybal_DB_RFP_Amendment_01.pdf PDF
08_Roybal_room_requirements_Pg_117-138.pdf PDF
Roybal_Pre_proposal_Conference_Final_05_28_2015_(1).pdf PDF
Appendix_C_Roybal_Swing_Space_Requirements_and_Move_Matrix_04_06_2015.pdf PDF
Roybal_Fed_Bldg_BER_Final_Submittal.pdf PDF
Roybal_Fed_Bldg_BER_Final_Submittal_Appendices.pdf PDF
AmendmenttoAppendixCSwingSpaceandMovesSOWFinal.doc.pdf PDF
Roybal_DB_RFP_preproposal_attendees.pdf PDF
Volume_3_-_References.pdf PDF
Past_Performance_Questionnaire.docx DOCX document
Volume_2B_Roybal_PDS_and_Appendix.pdf PDF
VOLUME_2A_SCOPE_OF_WORK.pdf PDF
Roybal_DB_1442.pdf PDF
Roybal_DB_RFP_Agreement.pdf PDF
Roybal_DB_Division_1.pdf PDF
Roybal_DB_Solicitation.pdf PDF
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

6United States General Service Administration

PROGRAM DEVELOPMENT STUDY – FINAL SUBMITTAL

Edward R. Roybal Federal Building and U.S. Courthouse 8.0 IMPLEMENTATION PLAN

Joseph Chow & Associates, Inc. 8.0 - 139 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Do not remove this notice. Properly destroy documents when no longer required

ROOM REQUIREMENTS

The Room Requirements tables below represent preliminary information from the User describing general requirements. During the design process, the Design/Build Contractor shall work with the Users to confirm the room requirements and effectively utilize the maximum allowable space.

9.1 NINTH FLOOR – USBC RECORDS

9.1.1 USBC Active Records

ROOM: 934-01

Space Characteristics

Function/adjacencies: USBC: Open Storage Space.

Special Dimensions: Provide 9’-0” min. ceiling height.

Access: Access is from the existing Elevator Lobby.

Courts’ POR Reference: 5.4.3

Special Requirements: Open floor area for record storage.

Uniformat

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Some existing walls.

Provide new entry door into Suite.

Wall Type A - Walls shall be full height Gypsum wall board (GWB) over metal studs. Painted.

Provide new paint on existing walls.

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

C1020 Interior Doors EA Building standard.

Joseph Chow & Associates, Inc. 8.0 - 140 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in Appendix A.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF Vinyl Composition Tile (VCT).

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

LF As

Required

D4040 Sprinkler

Systems

EA As

D502001 Branch Wiring As

Req’d

Distributed convenience outlets, including provisions for cleaning equipment/motor loads.

Min. one quadruplex receptacle (general use).

Duplex outlet(s), isolated ground- one minimum.

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 909.

Connect security infrastructure to this room as required.

Joseph Chow & Associates, Inc. 8.0 - 141 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

E202003 Freestanding

Furniture

EA Freestanding office furniture. Office furniture includes open shelving. Provide seismic restraints as required for the storage cabinets.

FF & E.

Joseph Chow & Associates, Inc. 8.0 - 142 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

- Page Left Intentionally Blank -

Joseph Chow & Associates, Inc. 8.0 - 143 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

9.1.2 USBC Secure Records

ROOM: 934-02

Function/adjacencies: USBC: Secured Space.

Access: Access from Active Records.

Courts’ POR Reference: 5.6.3

Special Requirements: Shall be a fully secured room that contains records that need to be secured.

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF Wall Type E - Slab to slab wall construction 3-

5/8” x 20 ga studs with 1 layer of 5/8” gypsum board. 9-Gauge steel or expanded metal mesh on inner side of partitions and above ceiling.

Security screen to be attached to floor slab and structure above and welded to all structural members and studs to form a contiguous barrier against entry.

C1020 Interior Doors EA Hollow metal door and frame.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF Vinyl Composition Tile (VCT).

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 144 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502001 Branch Wiring As

Req’d

Distributed convenience outlets, including

Duplex outlet(s), isolated ground- one minimum.

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 909.

Connect security infrastructure to this room as required.

E202003 Freestanding

Furniture

EA Freestanding office furniture. Office furniture includes storage cabinets. Provide seismic restraints as required for the storage cabinets.

Joseph Chow & Associates, Inc. 8.0 - 145 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

9.1.3 USBC Record’s Work Area

ROOM: 934-03

Function/adjacencies: USBC: Open Work Area.

Access: Access is from 934-01.

Courts’ POR Reference: 5.3.6

Special Requirements: Scanning Area

Medium volume copy area

Shared printer area

Uniformat

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF N/A. Open office area.

C1020 Interior Doors EA N/A.

C102007 Interior Door

Hardware

As

Req’d

N/A.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 146 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502001 Branch Wiring As

Req’d

One quadruplex outlet (per cubicle), Outlets/feeds to powered furniture panel as required. Distributed convenience outlets as required. Minimum one quadriplex outlet

(general purpose). Coordinate number of outlets and types with tenant-supplied equipment.

One isolated ground duplex outlet (per cubicle).

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202002 Modular

Prefabricated

Furniture

EA Low height, demountable modular furniture open workstation. FF & E.

E202003 Freestanding

Furniture

EA Freestanding office furniture. FF & E.

Joseph Chow & Associates, Inc. 8.0 - 147 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

9.2 NINTH FLOOR – USBC OPERATIONS | COURTROOM SERVICES

9.2.1 USBC Deputy Clerk’s Open Office Operations/Courtroom Services Open Office

ROOMS: 957-01, 957-03

Courts’ POR Reference: 5.3.5

Special Requirements:

Section

Provide new entry door into Suite. Walls shall be Gypsum wall board (GWB) over metal studs.

Painted. Provide new paint on existing walls.

Wall Type A - Full height metal studs with slab to slab acoustically sealed drywall with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

C1020 Interior Doors EA Building standard.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in Appendix A.

Joseph Chow & Associates, Inc. 8.0 - 148 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

One quadruplex outlet (per cubicle), Outlets/feeds to powered furniture panel as

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 909.

Connect security infrastructure to this room as required.

E202002 Modular

Prefabricated

Furniture

EA Mid-height, demountable modular furniture partition. FF & E.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 149 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

9.2.2 USBC Courtroom Services Supervisor Office

ROOMS: 957-02, 957-05, 957-11 957-07, 957-09, 944-02, 944-03

Function/adjacencies: USBC: Private office.

Access: Access is from the Work Area.

Courts’ POR Reference: 5.3.2

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF Room 957-02 ONLY: Wall Type B - Ceiling height, demountable, modular furniture partition with custom panel width; transoms and borrowed lights should have the following:

Speech Intelligibility Index (STI) without sound system enhancement = 45.

Rooms 957-07, 957-09, 944-02, 944-03: N/A.

Existing walls.

C1020 Interior Doors EA Room 957-02 ONLY: Standard as per demountable wall system.

Rooms 957-07, 957-09, 944-02, 944-03: N/A.

Existing door.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 150 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D4040 Sprinkler

Systems

Distributed convenience outlets, including

Min. one quadriplex receptacle (general use).

Duplex outlet(s), isolated ground – two minimum.

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 151 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

9.2.3 USBC Courtroom Services Team Area

ROOMS: 957-06, 957-12, 957-05, 957-08

Function/adjacencies: USBC: Share collaborative work space.

Courts’ POR Reference: 5.6.8

Section

C101002 Fixed Partitions SF Room 957-08: N/A. Existing walls.

Room 957-05: Wall Type B - Ceiling height, demountable, modular furniture partition with custom panel width; transoms and borrowed lights should have the following:

Speech Intelligibility Index (STI) without sound system enhancement = 45.

C1020 Interior Doors EA Room 957-08: N/A. Existing door.

Room 957-05: Standard as per demountable wall system.

C102007 Interior Door

Hardware

As

Req’d

N/A. Provide mechanical lockset. Coordinate door hardware type and function with the

Users.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

Joseph Chow & Associates, Inc. 8.0 - 152 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 153 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

9.2.4 USBC Courtroom Services Work Area

ROOMS: 957-04, 957-07 957-11, 934-04, 940-06

Function/adjacencies: USBC: Open work area.

Access: Access is from the open office area.

Special Requirements: Scanning Area

Medium volume copy area

Shared printer area

Uniformat

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF N/A.

C1020 Interior Doors EA N/A.

C102007 Interior Door

Hardware

As

Req’d

N/A.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 154 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502001 Branch Wiring As

Req’d

One quadruplex outlet (per cubicle), Outlets/feeds to powered furniture panel as required. Distributed convenience outlets as required. Minimum one quadriplex outlet

(general purpose). Coordinate number of outlets and types with tenant-supplied equipment.

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202002 Modular

Prefabricated

Furniture

EA Low-height, demountable modular furniture partition in Work Area 957-07. FF & E.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 155 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

9.2.5 USBC Meeting Room

ROOMS: 957-08, 957-09, 957-10 957-12, 957-13

Function/adjacencies: USBC: Meeting Room.

Courts’ POR Reference: 5.6.11

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF Wall Type B - Ceiling height, demountable, modular furniture partition with custom panel width; transoms and borrowed lights should have the following:

C1020 Interior Doors EA Standard as per demountable wall system.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 156 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502001 Branch Wiring As

Req’d

Distributed convenience outlets, including

Coordinate outlet types with tenant supplied equipment.

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

60 FTC with dimming control.

D503001 Telecom. System EA Two outlets and one wall phone outlet, one

MATV outlet. Provide conduit and outlet boxes for video conferencing system. Video conference system equipment will be provided by the Courts.

Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 157 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

9.3 NINTH FLOOR – USBC EXECUTIVE SUITE

9.3.1 USBC Executive Open Office

ROOM: 944-01

Courts’ POR Reference: 5.3.4

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF N/A. Open office area.

C1020 Interior Doors EA N/A

C102007 Interior Door

Hardware

As

Req’d

N/A

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

One quadruplex outlet (per cubicle), Joseph Chow & Associates, Inc. 8.0 - 158 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202002 Modular

Prefabricated

Furniture

EA Mid-height, demountable modular furniture partition. FF & E.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 159 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

DELETE, Not used: 9.3.2 USBC Executive Team Area

ROOM: 944-02

Function/adjacencies: USBC: Shared collaborative work space.

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF N/A. Existing walls.

C1020 Interior Doors EA N/A.

C102007 Interior Door

Hardware

As

Req’d

N/A.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including

Joseph Chow & Associates, Inc. 8.0 - 160 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 161 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

9.3.3 USBC Deputy Clerk-in Charge’s MANAGER Office

ROOM: 944-03 957-10

Courts’ POR Reference: 5.3.1

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type C - Drywall metal partition to 6" above ACT ceiling with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

N/A. Existing walls.

C101005 Interior Windows SF Provide tempered glass sidelight with hollow metal frame. N/A. Existing walls.

C1020 Interior Doors EA Building standard. N/A. Existing door.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C3010 Wall Finishes SF Wood chair rail. Paint.

C3020 Floor Finishes SF 24” x 24” Carpet Tile.

C3020 Floor Finishes LF 4” min. Wood base. Vinyl base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC with thermostat control.

Joseph Chow & Associates, Inc. 8.0 - 162 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including

Duplex isolated ground outlet(s), two minimum.

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 163 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

9.3.4 USBC Deputy Clerk’s Office

Rooms: 944-04 957-06

Courts’ POR Reference: 5.3.3

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF Wall Type B - Ceiling height, demountable, modular furniture partition with custom panel width; transoms and borrowed lights should have the following:

N/A. Existing walls.

C1020 Interior Doors EA Standard as per demountable wall system.

N/A. Existing door.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C3010 Wall Finishes SF Paint. Wood chair rail.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base. Wood base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 164 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502001 Branch Wiring As

Req’d

Distributed convenience outlets, including

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 165 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

9.4 NINTH FLOOR – USBC STAFF DEVELOPMENT

OPERATIONS/COURTROOM SERVICES

9.4.1 USBC Staff Development Work Area Open Office

ROOM: 940-01

Access: Access is from the existing building corridor.

Courts’ POR Reference: 5.2.3

Section

Provide new entry door into Suite. Walls shall be Gypsum wall board (GWB) over metal studs.

Painted. Provide new paint on existing walls.

Wall Type A - Full height metal studs with slab to slab acoustically sealed drywall with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

C1020 Interior Doors EA N/A.

C102007 Interior Door

Hardware

As

Req’d

N/A.

C3010 Wall Finishes SF Paint.

Joseph Chow & Associates, Inc. 8.0 - 166 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

One quadruplex outlet (per cubicle), Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202002 Modular

Prefabricated

Furniture

EA Low height, modular furniture open workstation.

Joseph Chow & Associates, Inc. 8.0 - 167 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

9.4.2 USBC Staff Development Operations/Courtroom Services Team Area

ROOM: 940-02

Function/adjacencies: USBC: Shared collaborative work space.

Section Description Qty Size

Specific Requirements

C101001 Fixed Partitions SF N/A. Existing walls.

C1020 Interior Doors EA N/A. Existing door.

C102007 Interior Door

Hardware

As

Req’d

N/A. Existing door hardware.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including

Joseph Chow & Associates, Inc. 8.0 - 168 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size

Specific Requirements

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 169 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

9.4.3 USBC Courtroom Services Future Manager’s Office (Room 944-04)

USBC Courtroom Services Future Supervisor’s Office (Rooms 940-03 and 940-04)

ROOMS: 940-03, 940-04, 944-04

Courts’ POR Reference: 5.3.2 and 5.3.3

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF Room 940-03 and 940-04: Wall Type B -

Ceiling height, demountable, modular furniture partition with custom panel width; transoms and borrowed lights should have the following:

Exception: Room 944-04 has existing walls.

C1020 Interior Doors EA Standard as per demountable wall system.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 170 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D4040 Sprinkler

Systems

Distributed convenience outlets, including

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 171 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

9.4.4 USBC Courtroom Services Open Office

ROOM: 940-05

Courts’ POR Reference: 5.3.5

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A. Open office area.

C1020 Interior Doors EA N/A

C102007 Interior Door

Hardware

As

Req’d

N/A

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

One quadruplex outlet (per cubicle), Equipment

As

Req’d

Provided lighting fixtures to meet the

Joseph Chow & Associates, Inc. 8.0 - 172 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202002 Modular

Prefabricated

Furniture

EA Mid-height, demountable modular furniture partition. FF & E.

Joseph Chow & Associates, Inc. 8.0 - 173 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

DELETE: 9.4.5 USBC Courtroom Services Work Area

ROOM: 940-06

Function/adjacencies: USBC: Open work area.

Special Requirements: Scanning Area (@ 25 SF ea)

Medium volume copy area (@ 80 SF ea)

Shared printer area (@ 50 SF ea)

Uniformat

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A.

C1020 Interior Doors EA Building Standard.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in Appendix A.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 174 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502001 Branch Wiring As

Req’d

Distributed convenience outlets as required.

Minimum one quadriplex outlet (general purpose). Coordinate number of outlets and types with tenant-supplied equipment.

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 909.

Connect security infrastructure to this room as required.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 175 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

9.5 NINTH FLOOR – USBC SHARED BREAK ROOM

9.5.1. USBC Shared Break Room

ROOM: 952

Function/adjacencies: USBC: Break Area.

Access: Access is from the 957-07.

Courts’ POR Reference: 5.6.1

Special Requirements: Design an area for recycle bins.

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type A - Full height metal studs with slab to slab acoustically sealed drywall with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

C101006 Glazed Partitions and Storefronts

SF New storefront glazing and door assembly.

C1020 Interior Doors EA Standard as per storefront assembly. Door shall be full glass.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C103002 Break Room

Accessories

EA Provide ABAAS compliant liquid soap dispenser and paper towel dispenser.

Joseph Chow & Associates, Inc. 8.0 - 176 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C103008 Counters LF 72” long minimum. Counter to be 24” deep with

4” high back and side splashes. Cut out counter to accommodate drop in sink.

C103009 Cabinets LF ABAAS compliant millwork plastic laminate on all exposed surfaces. Space to be provided for separate, tenant supplied stand-alone refrigerator.

Under counter built-in microwave compartment.

Provide cabinets and drawers below counter and overhead cabinets.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF Vinyl Composition Tile (VCT).

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D2010 Plumbing

Fixtures

EA One ABAAS compliant stainless steel sink (with garbage disposal) with gooseneck faucet, hot and cold lever handles. Provide plastic cold water line to icemaker in refrigerator.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Seven dedicated GFI duplex outlets. Three at counter, two for refrigerator, one below cabinet for build-in microwave and one switched for garbage disposal. Provide water lines for refrigerators. Install switch at countertop near sink. Provide two additional outlets to supply two vending machines.

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the

Separately switched fluorescent fixtures and under cabinet fluorescent lighting.

Joseph Chow & Associates, Inc. 8.0 - 177 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D503001 Telecom. System EA Two isolated ground outlets and one wall phone outlet, one CATV outlet.

Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Furniture

EA Courts will provide freestanding office furniture, two vending machines, and two refrigerators -

Joseph Chow & Associates, Inc. 8.0 - 178 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Joseph Chow & Associates, Inc. 8.0 - 179 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

9.6 NINTH FLOOR – USBC COMPUTER TRAINING ROOM

9.6.1 USBC Computer Training Room

ROOM: 941

Function/adjacencies: USBC: Computer Training Room

Special Dimensions: Provide 10’-0” min. ceiling height.

Access: Access is from elevator lobby.

Courts’ POR Reference: 5.6.6

Special Requirements: Verify specific infrastructure requirements with the court (i.e. electrical, telecom, floor boxes, etc…).

Uniformat

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type A - Full height metal studs with slab to slab acoustically sealed drywall with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

N/A. Existing walls.

C101006 Glazed Partitions and Storefronts

SF Existing glass wall to remain.

N/A. Existing walls.

C1020 Interior Doors EA Building Standard. New double door entry.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in Appendix A.

C3010 Wall Finishes SF Paint.

Joseph Chow & Associates, Inc. 8.0 - 180 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C3020 Floor Finishes SF 24” x 24” Carpet Tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including provisions for cleaning equipment/motor loads.

Multiple outlets (as required) and Multiple isolated ground outlets (as required) for sound, ALS, data, telecommunication and video recording and presentation equipment as per court direction.

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the

Provide recessed down lighting with dimming capacity.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 909.

Connect security infrastructure to this room as required.

E201002 Window

Treatments:

EA Provide black out shades.

Joseph Chow & Associates, Inc. 8.0 - 181 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

E102009 Audio-Visual

Equipment

As

Req’d

Provide backing for min. two (2) ceiling mounted presentation projections. Audio video equipment will be provided by the Courts.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 182 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Joseph Chow & Associates, Inc. 8.0 - 183 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

9.7 NINTH FLOOR – USBC DATA CLOSET

9.7.1 USBC Data Closet

ROOM: 908

Function/adjacencies: USBC: Data Closet.

Special Dimensions: None.

Access: Access from the building corridor.

Courts’ POR Reference: N/A

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A. Existing.

C1020 Interior Doors EA Building Standard.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 12” x 12” Vinyl Composition Tile (VCT). Patch existing floor where wall was removed.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF Exposed ceiling.

D304007 Exhaust Systems MBH KW 24 hour DX cooling systems will require condensate drains per the U.S. Courts Design

Guide 2007.

D4010 Fire Alarm and

Detection System

LF Provide as required.

D4040 Sprinkler

Systems

EA As

Required

Provide as required.

D502001 Branch Wiring As

Req’d

Provide as required for new equipment.

Coordinate with the Courts Telecommunication vendor for power.

Joseph Chow & Associates, Inc. 8.0 - 184 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.