Roybal_DB_RFP_Amendment_04_14th_Fl_Room_Reqs.pdf

PDF 1 MB Posted

Attached to
Edward R. Roybal Repair and Alteration Tenant Improvement Prospectus Project
Solicitation number
GS-09P-15-KT-C-0014
Issued by

About this file

14th Fl Room Requirements

View the file

Other files

File Type Posted
Roybal_DB_RFP_Amendment_06.pdf PDF
Roybal_DB_RFP_Amendment_05.pdf PDF
Roybal_DB_RFP_Amendment_04.pdf PDF
Roybal_DB_RFP_Amendment_04_6th_FL_room_reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_revised_bid_sheet.pdf PDF
Roybal_DB_RFP_Amendment_04_9th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_scope_reductions.pdf PDF
Roybal_DB_RFP_Amendment_04_16th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_8th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_15th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_10th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_7th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Certificate_of_Current_Cost_or_Pricing_Data_(1).pdf PDF
Roybal_DB_RFP_Amendment_03_SF30.pdf PDF
Roybal_DB_bid_sheet_Amendment_03.pdf PDF
Roybal_DB_RFP_PPQ_Amendment_02.docx DOCX document
Roybal_DB_bid_sheet_Amendment_02.pdf PDF
Roybal_DB_RFP_Offeror_Representations_and_Certifications.doc DOC document
Roybal_DB_RFP_Amendment_02_SF30.pdf PDF
Roybal_DB_RFP_Amendment_01.pdf PDF
08_Roybal_room_requirements_Pg_117-138.pdf PDF
Roybal_Pre_proposal_Conference_Final_05_28_2015_(1).pdf PDF
Appendix_C_Roybal_Swing_Space_Requirements_and_Move_Matrix_04_06_2015.pdf PDF
Roybal_Fed_Bldg_BER_Final_Submittal.pdf PDF
Roybal_Fed_Bldg_BER_Final_Submittal_Appendices.pdf PDF
AmendmenttoAppendixCSwingSpaceandMovesSOWFinal.doc.pdf PDF
Roybal_DB_RFP_preproposal_attendees.pdf PDF
Volume_3_-_References.pdf PDF
Past_Performance_Questionnaire.docx DOCX document
Volume_2B_Roybal_PDS_and_Appendix.pdf PDF
VOLUME_2A_SCOPE_OF_WORK.pdf PDF
Roybal_DB_1442.pdf PDF
Roybal_DB_RFP_Agreement.pdf PDF
Roybal_DB_Division_1.pdf PDF
Roybal_DB_Solicitation.pdf PDF
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

United States General Service Administration

PROGRAM DEVELOPMENT STUDY – FINAL SUBMITTAL

Edward R. Roybal Federal Building and U.S. Courthouse 8.0 IMPLEMENTATION PLAN

Joseph Chow & Associates, Inc. 8.0 - 325 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Do not remove this notice. Properly destroy documents when no longer required

ROOM REQUIREMENTS

The Room Requirements tables below represent preliminary information from the User describing general requirements. During the design process, the Design/Build Contractor shall work with the Users to confirm the room requirements and effectively utilize the maximum allowable space.

14.1 FOURTEENTH FLOOR – PRETRIAL – INVESTIGATIVE | LM UNIT

Provide a peep hole for all doors going from secure office space to the public corridor. For additional door hardware not indicated in these Room Requirements, see USMS security drawings in Appendix A.

14.1.1 Pretrial Gun

ROOM: 1445-01

Space Characteristics

Function/adjacencies: Pretrial: Gun locker.

Special Dimensions: Provide 9’-0” min. ceiling height.

Access: Access is from the existing building corridor.

Courts’ POR Reference: 7.4.12

Special Requirements: Shall be a fully secured room that contains a gun locker within it. Provide blocking along length of one wall for all-mounted gun holders.

Uniformat

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type E - Slab to slab wall construction, 3-

5/8” x 20 ga studs with 1 layer of 5/8” gypsum board. Full height 9-Gauge steel or expanded metal mesh on inner side of partitions and above ceiling. Security screen to be attached to floor slab and structure above and welded to all structural members and studs to form a contiguous barrier against entry. Provide high security plaster finish.

C1020 Interior Doors EA Hollow metal.

Joseph Chow & Associates, Inc. 8.0 - 326 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in Appendix A.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF Vinyl Composition Tile (VCT).

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

LF As

Required

D4040 Sprinkler

Systems

EA As

D502001 Branch Wiring As

Req’d

Distributed convenience outlets, including provisions for cleaning equipment/motor loads.

Duplex outlet (s), isolated ground- one minimum.

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 1409.

Connect security infrastructure to this room as required.

Joseph Chow & Associates, Inc. 8.0 - 327 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

14.1.2 Pretrial Officer’s Office

Local Monitoring Unit’s Office

Investigations Unit’s Office

Supervisor’s Office

ROOMS: 1445-02, 1445-03, 1445-04, 1445-05, 1445-06, 1445-07, 1445-08, 1445-09, 1445-10, 1445-

11, 1445-12, 1445-13, 1445-14, 1445-15, 1445-27, 1445-28, 1445-30, 1445-31, 1445-32, 1445-33, 1445-34, 1445-35, 1445-36, 1445-37, 1445-38, 1445-40, 1445-41, 1445-43, 1445-

Function/adjacencies: Pretrial: Private office.

Access: Access is from the open office area.

Courts’ POR Reference: 5.3.2

Special Requirements:

Uniformat

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF Wall Type A (Room 1445-18 ony) - Full height metal studs with slab to slab acoustically sealed drywall with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

Wall Type B - Ceiling height, demountable, modular furniture partition with custom panel width; transoms and borrowed lights should have the following:

Speech Intelligibility Index (STI) without sound system enhancement = 45.

Joseph Chow & Associates, Inc. 8.0 - 328 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C1020 Interior Doors EA Standard as per demountable wall system.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including

Min. one quadruplex receptacle (general use).

Duplex isolated ground outlet(s), two minimum.

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Furniture

EA Freestanding office furniture. FF & E.

Joseph Chow & Associates, Inc. 8.0 - 329 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

14.1.3 PreTrial Officer’s Office

Local Monitoring Unit’s Office

Investigations Unit’s Office

Supervisor’s Office

ROOMS: 1445-18, 1445-19, 1445-21, 1445-22, 1455-23, 1445-24, 1445-25, 1445-39, 1445-42, 1445-45

Courts’ POR Reference: 5.3.2

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type C - Drywall metal partition to 6" above ACT ceiling with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

C101002 Fixed Partitions SF Wall Type B - Ceiling height, demountable, modular furniture partition with custom panel system enhancement = 45

C1020 Interior Doors EA Standard as per demountable wall system.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C3010 Wall Finishes SF Paint.

Joseph Chow & Associates, Inc. 8.0 - 330 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 331 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

14.1.4 Pretrial Location Monitoring Supplies (LMS) Storage/Work Area

ROOM: 1445-20

Function/adjacencies: Pretrial: Open Work Area/Storage Space.

Courts’ POR Reference: 7.4.15

Special Requirements: Area should be located near an outside wall for transmission reception.

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type C - Drywall metal partition to 6" above ACT ceiling with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

C101002 Fixed Partitions SF Wall Type B - Ceiling height, demountable, modular furniture partition with custom panel system enhancement = 45

C1020 Interior Doors EA Standard as per demountable wall system.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C103008 Counters LF Counter to be 24” deep with 4” high back and side splashes.

Joseph Chow & Associates, Inc. 8.0 - 332 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C103009 Cabinets LF ABAAS compliant millwork plastic laminate on all exposed surfaces. Knee space shall be provided. Provide cabinets and drawers below counter and overhead cabinets.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Systems furniture electrical requirements for powered furniture panels (subject to verification with awarded vendor): 8 wire, 4 circuit system: 2 hots, 1 shared neutral , 1 shared ground for house outlets, 2 hots, 1 isolated shared neutral and 1 isolated shared ground for equipment per cubicle.

For counters, provide adequate outlets for charging and testing equipment.

Distributed convenience outlets including

Minimum one quadruplex outlet (general purpose). Coordinate number of outlets and types with tenant-supplied equipment.

One isolated ground duplex outlet (per cubicle).

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

Joseph Chow & Associates, Inc. 8.0 - 333 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202002 Modular

Prefabricated

Furniture

EA Low height, modular furniture open workstation.

FF & E.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 334 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

- Page Left Intentionally Blank -

Joseph Chow & Associates, Inc. 8.0 - 335 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

14.1.5 Pretrial Financial Vault

ROOM: 1445-46

Function/adjacencies: Pretrial: Secure room.

Courts’ POR Reference: 7.4.13

Special Requirements: Shall be a fully secured room that contains a safe within it.

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type E - Slab to slab wall construction, 3-

5/8” x 20 ga studs with 1 layer of 5/8” gypsum board. 9-Gauge steel or expanded metal mesh on inner side of full height partitions and above ceiling. Security screen to be attached to floor slab and structure above and welded to all structural members and studs to form a contiguous barrier against entry.

C1020 Interior Doors EA Hollow metal.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in Appendix A.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF Vinyl Composition Tile (VCT).

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF Painted Gypsum Board.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 336 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502001 Branch Wiring As

Req’d

Duplex outlet (s), isolated ground- one

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 1409.

Connect security infrastructure to this room as

Joseph Chow & Associates, Inc. 8.0 - 337 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

14.1.5 Pretrial Work Area

ROOM: 1445-16

Function/adjacencies: Pretrial: Work area.

Courts’ POR Reference: None.

Special Requirements: Area to accommodate criminal records computers, scanners, printers, copiers, fax machines, and shredders, and the storage of equipment, and office supplies.

Uniformat

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type D - Drywall partition to 6” above

ACT ceiling – no insulation.

C1020 Interior Doors EA N/A.

C102007 Interior Door

Hardware

As

Req’d

N/A.

C103008 Counters LF ABAAS compliant millwork plastic laminate on all exposed surfaces. Counter to be 24” deep with

4” high back and side splashes.

C103009 Cabinets LF ABAAS compliant millwork plastic laminate on all exposed surfaces. Provide cabinets and drawers below counter and overhead cabinets.

Provide stand up height with knee clearance.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 338 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D4040 Sprinkler

Systems

Outlets/feeds to powered furniture panel as required. Coordinate number of outlets and types with tenant supplied equipment in each work area.

Provide normal power for full-size copier and shredder. (Copier and shredder shall be provided by the Courts – FF & E.)

Equipment

As

Req’d

Provided lighting fixtures to meet the

Separately switched fluorescent fixtures and under cabinet fluorescent lighting.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 339 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

14.1.6 Pretrial LM Unit Open Office / Team Area

ROOMS: 1445-17, 1445-26. 1445-29

Function/adjacencies: Pretrial: Open Work Area.

Courts’ POR Reference: 7.2.2

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A. Open office area.

C1020 Interior Doors EA N/A.

C102007 Interior Door

Hardware

As

Req’d

N/A.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 340 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502001 Branch Wiring As

Req’d

Systems furniture electrical requirements for powered furniture panels (subject to verification with awarded vendor): 8 wire, 4 circuit system: 2 hots, 1 shared neutral , 1 shared ground for house

One quadruplex outlet (per cubicle).

Minimum one quadruplex outlet (general purpose). Coordinate number of outlets and types with tenant-supplied equipment.

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202002 Modular

Prefabricated

Furniture

EA Mid-height, demountable modular furniture partition. FF & E.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 341 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

14.2 FOURTEENTH FLOOR – PRETRIAL – EXECUTIVE/

ADMINSTRATIVE

14.2.1 Pretrial Executive/Administrative Open Office

ROOM: 1468-01, 1468-15

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A. Open office area.

C1020 Interior Doors EA N/A.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in Appendix A. Provide a door peep hole from door going from secure office space to the public corridor.

C101005 Interior Windows SF Provide break-resistant glass with pass-through.

C103002 Toilet

Accessories

EA Provide one convex mirror from Open Office

1468-15 to 1468-06 so that you can see into the corridor but not into the open space.

C103008 Counters LF 1468-15: ABAAS compliant transaction counter. Millwork below counter on staff side to be custom-designed for form storage. Provide break-resistant glazing at each transaction window per USCDG, Chapter 14. ABAAS compliant mill work plastic laminate on all exposed surfaces. Counter to be 24” deep.

Joseph Chow & Associates, Inc. 8.0 - 342 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C103009 Cabinets LF 1468-15: ABAAS compliant millwork plastic laminate on all exposed surfaces. Provide cabinets and drawers below counter. Provide stand up height with knee clearance. No overhead cabinets.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Systems furniture electrical requirements for powered furniture panels (subject to verification with awarded vendor): 8 wire, 4 circuit system: 2 hots, 1 shared neutral , 1 shared ground for house

Minimum one quadruplex outlet (general purpose). Coordinate number of outlets and types with tenant-supplied equipment.

Equipment

As

Req’d

Provided lighting fixtures to meet the

Joseph Chow & Associates, Inc. 8.0 - 343 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 1409.

Connect security infrastructure to this room as required.

E202002 Modular

Prefabricated

Furniture

EA Mid-height, demountable modular furniture partition. FF & E.

Joseph Chow & Associates, Inc. 8.0 - 344 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Joseph Chow & Associates, Inc. 8.0 - 345 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

14.2.2 Pretrial Executive/Administrative Work Area

ROOMS: 1468-02, 1468-16

Courts’ POR Reference: 3.2.7

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type D - Drywall partition to 6” above

ACT ceiling – no insulation.

C1020 Interior Doors EA N/A.

C102007 Interior Door

Hardware

As

Req’d

N/A.

C103008 Counters LF Counter to be 24” deep with 4” high back and side splashes.

C103009 Cabinets LF ABAAS compliant millwork plastic laminate on all exposed surfaces. Knee space shall be provided. Provide cabinets and drawers below counter and overhead cabinets.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 346 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502001 Branch Wiring As

Req’d

Outlets feed to powered furniture panel as required. Distributed convenience outlets as required. Minimum one quadruplex outlet

(general purpose). Coordinate number of outlets and types with tenant supplied equipment.

Courts shall provide copier and shredder – FF &

E.

Provide 20-amp outlet with a Nema type outlet for full size copier in Room 1468-02.

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 347 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

14.2.3 Pretrial Executive/Administrative Urinalysis Lab/Storage

ROOM: 1468-03

Function/adjacencies: Pretrial: Lab/Storage room.

Access: Access near the interview rooms.

Courts’ POR Reference: 7.4.8

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type A - Full height metal studs with slab to slab acoustically sealed drywall with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

C1020 Interior Doors EA Building standard.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C103008 Counters LF ABAAS compliant millwork plastic laminate on all exposed surfaces. Counter to be 24” deep with

4” high back and side splashes.

C103009 Cabinets LF ABAAS compliant millwork plastic laminate on all exposed surfaces. Space to be provided for separate, tenant supplied stand-alone refrigerator.

Under counter built-in microwave compartment.

Provide cabinets and drawers below counter and

Joseph Chow & Associates, Inc. 8.0 - 348 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C3020 Floor Finishes SF Vinyl Composition Tile (VCT).

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including provisions for cleaning equipment/motor loads.

Min. one dedicated GFI duplex.

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition

D503001 Telecom. System EA One wall phone and data outlet.

Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Furniture

EA Provide a small refrigerator for UA Supply room

- FF & E.

Joseph Chow & Associates, Inc. 8.0 - 349 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

14.2.4 Pretrial Executive/Administrative Urinalysis Collection Room (Toilet Rooms)

ROOMS: 1468-04, 1468-05

Function/adjacencies: Pretrial: Unisex Restrooms

Access: Access from Corridor 1468-06.

Courts’ POR Reference: 7.4.7

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF Wall Type A - Provide slab to slab metal stud walls with moisture resistant cement board with tile.

Provide soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

C1020 Interior Doors EA Building standard.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C103004 Identifying

Devices

EA Room ID Signage.

C103002 Toilet

Accessories

EA Provide ABAAS compliant wall-mounted toilet paper holder, mirrors, hand dryers, liquid soap dispenser, toilet seat cover dispenser and toilet grab bars with backing. Provide one mirror above the sink, one at the back side of the toilet, and one at the side of the toilet.

Joseph Chow & Associates, Inc. 8.0 - 350 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C3010 Wall Finishes SF Ceramic wainscot 5-ft high. Paint above ceramic tile wainscot.

C3020 Floor Finishes SF Ceramic tile. Tiles shall be rectified to minimize width of grout joint for easier maintenance.

C3020 Floor Finishes LF 4” min. Ceramic wall base with sanitary cove.

C3030 Ceiling Finishes SF Painted Moisture Resistant GWB Ceiling.

Provide access panels as required.

D2010 Plumbing

Fixtures

EA ABAAS compliant water closet and wash basin with faucet and lever handles.

D2020 Domestic Water

Distribution

EA

D304007 Exhaust Systems MBH KW Building standard HVAC and exhaust fan.

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including provisions for cleaning equipment/motor loads.

Min. one dedicated GFI duplex outlet near sink.

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the

Fixtures to have translucent, moisture resistant, non-breakable protective covers.

Joseph Chow & Associates, Inc. 8.0 - 351 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

14.2.5 Pretrial Executive/Administrative Urinalysis Corridor

ROOM: 1468-06

Function/adjacencies: Pretrial: Circulation.

Access: Access from open office.

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type A - Provide slab to slab metal stud

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

C101005 Interior Windows SF 3’ x 4’ Provide two way mirrors between Executive

Administrator & Corridor 1468-06.

C1020 Interior Doors EA Building standard.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in Appendix A.

C3020 Floor Finishes SF Vinyl Composition Tile (VCT).

Joseph Chow & Associates, Inc. 8.0 - 352 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Building standard HVAC.

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including provisions for cleaning equipment/motor loads.

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the

Fixtures to have translucent, moisture resistant, non-breakable protective covers.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support USMS security equipment. The existing security equipment room is located in

Room 1409. Connect security infrastructure to this room as required.

Joseph Chow & Associates, Inc. 8.0 - 353 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

14.2.6 Pretrial Executive/Administration Office

Clerk Supervisor’s Office

Manager’s Office

ROOMS: 1468-07, 1468-08, 1468-09, 1468-10

Courts’ POR Reference: 5.2.1 and 5.4.2

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type C - Drywall metal partition to 6" above ACT ceiling with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

C101002 Fixed Partitions SF Wall Type B -Ceiling height, demountable, modular furniture partition with custom panel system enhancement = 45.

C1020 Interior Doors EA Standard as per demountable wall system.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

Joseph Chow & Associates, Inc. 8.0 - 354 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 355 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

14.2.7 Pretrial Executive/Administration Officer’s Office

Deputy Chief’s Office

Chief’s Office

ROOMS: 1468-11, 1468-12

Courts’ POR Reference: 5.2.1

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type A - Provide slab to slab metal stud

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

C1020 Interior Doors EA Hardwood veneer solid core door. Solid hardwood jambs, stops, and casings.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C3010 Wall Finishes SF Wood chair rail with wall covering above and below the chair rail.

C3020 Floor Finishes SY 26-28 oz. broadloom carpet over carpet pad.

C3020 Floor Finishes LF 4” min. Solid, stain grade hardwood

Joseph Chow & Associates, Inc. 8.0 - 356 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Building standard HVAC with thermostat control.

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including provisions for cleaning equipment/motor loads.

Min. one quadruplex receptacle (general use).

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 357 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

14.2.8 Pretrial Executive/Administration Conference Room

ROOM: 1468-13

Function/adjacencies: Pretrial: Conference Room.

Special Dimensions: Provide 10’-0” min. ceiling height.

Courts’ POR Reference: 5.1.2

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type A - Full height metal studs with slab to slab acoustically sealed drywall with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

C101007 Interior Glazing EA Tempered glass sidelight with hollow metal frame.

C1020 Interior Doors EA Hardwood veneer solid core door. Solid hardwood jambs, stops, and casings.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C3010 Wall Finishes SF Wood chair rail with wall covering above and below the chair rail.

C3020 Floor Finishes SY 26-28 oz. broadloom carpet over carpet pad.

C3020 Floor Finishes LF 4” min. Solid, stain grade hardwood.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

Joseph Chow & Associates, Inc. 8.0 - 358 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D304007 Exhaust Systems MBH KW Building standard HVAC with thermostat control.

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including

Provide floor outlet and data ports centered under conference table.

Provide power for video conferencing equipment provided by the Courts.

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Duplex isolated ground outlet(s), two minimum.

E1010 Commercial

Equipment

EA Video teleconferencing will be provided by the

Courts – FF & E. Contractor to provide infrastructure only and structural supports as needed only.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 359 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

14.2.9 Pretrial Executive/Administration Break Room

ROOM: 1468-14

Function/adjacencies: Pretrial: Break Room.

Courts’ POR Reference: 5.6.1

Special Requirements: Design an area for recycle bins.

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type C - Drywall metal partition to 6" above ACT ceiling with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

C1020 Interior Doors EA Hardwood veneer solid core door. Solid hardwood jambs, stops, and casings.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C103002 Break Room

Accessories

EA Provide ABAAS compliant liquid soap dispenser and paper towel dispenser.

C103008 Counters LF 72” long minimum. Counter to be 24” deep with

4” high back and side splashes. Cut out counter to accommodate drop in sink.

Joseph Chow & Associates, Inc. 8.0 - 360 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C103009 Cabinets LF ABAAS compliant millwork plastic laminate on all exposed surfaces. Space to be provided for separate, tenant supplied stand-alone refrigerator.

Under counter built-in microwave compartment.

Provide cabinets and drawers below counter and overhead cabinets.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SY Vinyl Composition Tile (VCT).

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D2010 Plumbing

Fixtures

EA One ABAAS compliant stainless steel sink (with garbage disposal) with gooseneck faucet, hot and cold lever handles. Provide plastic cold water line to Icemaker in refrigerator.

D304007 Exhaust Systems MBH KW Building standard HVAC with exhaust fan.

D4010 Fire Alarm and

Detection System

Six dedicated GFI duplex outlets. Three at counter, one for refrigerator, one below cabinet for built-in microwave and one switched for garbage disposal. Install switch at countertop near sink.

Two isolated ground outlets.

Equipment

As

Req’d

Provided lighting fixtures to meet the

Separately switched fluorescent fixtures and under cabinet fluorescent lighting.

Joseph Chow & Associates, Inc. 8.0 - 361 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D503001 Telecom. System EA One wall phone outlet and one CATV outlet.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Furniture

EA One large refrigerator, microwave, and coffee maker shall be provided by the Courts – FF & E.

Joseph Chow & Associates, Inc. 8.0 - 362 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Joseph Chow & Associates, Inc. 8.0 - 363 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

14.3 FOURTEENTH FLOOR – PRETRIAL - SUPPORT

14.3.1 Pretrial Reception/Waiting

ROOM: 1471-01

Function/adjacencies: Pretrial: Reception/Lobby.

Courts’ POR Reference: 7.4.1

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type A - Full height metal studs with slab to slab acoustically sealed drywall with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

C1020 Interior Doors EA Building standard.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in Appendix A.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24”x24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

Joseph Chow & Associates, Inc. 8.0 - 364 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Four duplex outlets in the waiting area. Two quadruplex outlets in the receptionist/counter area. Outlets/feeds to powered furniture panel as

Provide power to support two free standing kiosks.

One isolated ground duplex outlet at receptionist/counter.

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Data is needed to support two free standing kiosks. Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 1409.

Connect security infrastructure to this room as required.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 365 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

14.3.2 Pretrial Interview Room

ROOMS: 1471-02, 1471-03, 1471-04, 1471-05, 1471-06

Function/adjacencies: Pretrial: Interview room.

Access: Access is from the Reception/Waiting.

Courts’ POR Reference: 7.4.6.

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type C - Drywall metal partition to 6" above ACT ceiling.

Rooms that share walls with court space shall be

Wall Type A - Full height metal studs with slab to slab acoustically sealed drywall with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

C101007 Interior Glazing EA Tempered glass sidelight with hollow metal frame. Provide window blinds.

C1020 Interior Doors EA Building standard.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C3010 Wall Finishes SF Paint.

Joseph Chow & Associates, Inc. 8.0 - 366 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including provisions for cleaning equipment/motor loads.

Outlets for Courts provided computer and printer.

One isolated ground duplex outlet, minimum.

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition

D503001 Telecom. System EA Two data ports one wall phone outlet.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 1409.

Connect security infrastructure to this room as required.

E202003 Freestanding

E201002 Window

Treatments

EA Provide window treatment for each sidelight.

Joseph Chow & Associates, Inc. 8.0 - 367 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

14.3.3 Pretrial Learning Center

ROOM: 1472

Function/adjacencies: Pretrial: Learning center.

Access: Access is from the Reception/Waiting.

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type A - Full height metal studs with slab to slab acoustically sealed drywall with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

C101007 Interior Glazing EA Tempered glass sidelight with hollow metal frame.

C101090 Other Partitions EA Provide retractable/accordion wall with an STC of 40 minimum between the Learning Center and the adjacent Interview Room.

C1020 Interior Doors EA Building standard.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C3010 Wall Finishes SF Paint.

Joseph Chow & Associates, Inc. 8.0 - 368 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Provide 4-5 outlets. One isolated ground duplex outlet, minimum.

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA 4-5 data ports and one wall phone outlet

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 1409.

Connect security infrastructure to this room as required.

E1010 Commercial

Equipment

EA Video conferencing equipment will be provided by the Courts – FF & E. Contractor to provide infrastructure only and power only.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 369 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

14.4 FOURTEENTH FLOOR – USDC FUTURE CHAMBERS

14.4.1 USDC Future Chambers

ROOM: 1475

Function/adjacencies: USDC Storage.

Courts’ POR Reference: N/A.

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type A - Full height metal studs with slab to slab acoustically sealed drywall with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

C1020 Interior Doors EA Hardwood veneer solid core door with solid hardwood jambs, stops, and casings.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C3010 Wall Finishes SF Leave walls unpainted.

C3020 Floor Finishes SF Leave floor unfinished. Removal of existing finishes is part of the scope of work.

C3020 Floor Finishes LF N/A. Leave walls without a wall base.

C3030 Ceiling Finishes SF Ceiling open to structure above.

Joseph Chow & Associates, Inc. 8.0 - 370 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D304007 Exhaust Systems MBH KW Provide adequate HVAC with thermostat control.

D4010 Fire Alarm and

Detection System

One isolated ground duplex outlet.

Equipment

As

Req’d

Provided lighting to meet life and safety requirements only.

Joseph Chow & Associates, Inc. 8.0 - 371 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

14.5 FOURTEENTH FLOOR – USDC JUDGE’S CHAMBERS –

DELETED WORK SCOPE OPTION E

Note: The USDC Judge’s Chambers shall match the existing standard level of finishes and fit-out of the Roybal 5th Floor Chambers.

14.5.1 USDC Reception/Waiting – Option E

ROOM: 1475-01

Function/adjacencies: USDC Judge’s Chamber: Reception.

Courts’ POR Reference: 4.3.6

Section Description Qty Size Specific Requirements

Joseph Chow & Associates, Inc. 8.0 - 372 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type A - Full height metal studs with slab to slab acoustically sealed drywall with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

Adjacent to Secretary Area:

Wall Type C - Drywall metal partition to 6" above ACT ceiling with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

C1020 Interior Doors EA Hardwood veneer solid core door with solid hardwood jambs, stops, and casings.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in Appendix A.

C3010 Wall Finishes SF Wall covering.

C3020 Floor Finishes SF 42 oz. broadloom carpet over carpet pad in waiting area.

C3020 Floor Finishes LF 4” min. Solid, stain grade hardwood base.

D304007 Exhaust Systems MBH KW Provide adequate HVAC with thermostat control.

Joseph Chow & Associates, Inc. 8.0 - 373 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D4010 Fire Alarm and

Detection System

One isolated ground duplex outlet.

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 1409.

Connect security infrastructure to this room as required.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 374 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Joseph Chow & Associates, Inc. 8.0 - 375 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

14.5.2 USDC Judge’s Secretary – DELETED WORK SCOPE Option E

ROOM: 1475-02

Function/adjacencies: USDC Judge’s Chambers: Secretary.

Access: Access is from the reception area.

Courts’ POR Reference: 4.3.5

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A.

C1020 Interior Doors EA N/A.

C102007 Interior Door

Hardware

As

Req’d

N/A.

C3010 Wall Finishes SF Wall covering.

C3020 Floor Finishes SF 42 oz. broadloom carpet over carpet pad in waiting area.

C3020 Floor Finishes LF 4” min. Solid, stain grade hardwood base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

One quadruplex outlet.

Duplex outlet(s), isolated ground – two

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition

Joseph Chow & Associates, Inc. 8.0 - 376 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 377 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

14.5.3 USDC Judge’s Chambers – DELETED WORK SCOPE Option E

ROOM: 1475-03

Function/adjace…