Roybal_DB_RFP_Amendment_04_7th_Fl_Room_Reqs.pdf

PDF 440 KB Posted

Attached to
Edward R. Roybal Repair and Alteration Tenant Improvement Prospectus Project
Solicitation number
GS-09P-15-KT-C-0014
Issued by

About this file

7th Fl Room Requirements

View the file

Other files

File Type Posted
Roybal_DB_RFP_Amendment_06.pdf PDF
Roybal_DB_RFP_Amendment_05.pdf PDF
Roybal_DB_RFP_Amendment_04.pdf PDF
Roybal_DB_RFP_Amendment_04_14th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_6th_FL_room_reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_revised_bid_sheet.pdf PDF
Roybal_DB_RFP_Amendment_04_9th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_scope_reductions.pdf PDF
Roybal_DB_RFP_Amendment_04_16th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_8th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_15th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_10th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Certificate_of_Current_Cost_or_Pricing_Data_(1).pdf PDF
Roybal_DB_RFP_Amendment_03_SF30.pdf PDF
Roybal_DB_bid_sheet_Amendment_03.pdf PDF
Roybal_DB_RFP_PPQ_Amendment_02.docx DOCX document
Roybal_DB_bid_sheet_Amendment_02.pdf PDF
Roybal_DB_RFP_Offeror_Representations_and_Certifications.doc DOC document
Roybal_DB_RFP_Amendment_02_SF30.pdf PDF
Roybal_DB_RFP_Amendment_01.pdf PDF
08_Roybal_room_requirements_Pg_117-138.pdf PDF
Roybal_Pre_proposal_Conference_Final_05_28_2015_(1).pdf PDF
Appendix_C_Roybal_Swing_Space_Requirements_and_Move_Matrix_04_06_2015.pdf PDF
Roybal_Fed_Bldg_BER_Final_Submittal.pdf PDF
Roybal_Fed_Bldg_BER_Final_Submittal_Appendices.pdf PDF
AmendmenttoAppendixCSwingSpaceandMovesSOWFinal.doc.pdf PDF
Roybal_DB_RFP_preproposal_attendees.pdf PDF
Volume_3_-_References.pdf PDF
Past_Performance_Questionnaire.docx DOCX document
Volume_2B_Roybal_PDS_and_Appendix.pdf PDF
VOLUME_2A_SCOPE_OF_WORK.pdf PDF
Roybal_DB_1442.pdf PDF
Roybal_DB_RFP_Agreement.pdf PDF
Roybal_DB_Division_1.pdf PDF
Roybal_DB_Solicitation.pdf PDF
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

United States General Service Administration

PROGRAM DEVELOPMENT STUDY – FINAL SUBMITTAL

Edward R. Roybal Federal Building and U.S. Courthouse 8.0 IMPLEMENTATION PLAN

Joseph Chow & Associates, Inc. 8.0 - 105 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Do not remove this notice. Properly destroy documents when no longer required

ROOM REQUIREMENTS

The Room Requirements tables below represent preliminary information from the User describing general requirements. During the design process, the Design/Build Contractor shall work with the Users to confirm the room requirements and effectively utilize the maximum allowable space.

7.1 SEVENTH FLOOR – USDC JURY ASSEMBLY ROOM

7.1.1 USDC Jury Assembly Room

ROOM: 740

Space Characteristics

Function/adjacencies: USDC: Grand Jury Assembly Room.

Special Dimensions: Existing.

Access: Existing.

Courts’ POR Reference: 4.2.1

Special Requirements: An existing and repurposed USDC courtroom will be used for this space.

Verify specific infrastructure requirements with the court (i.e. electrical, telecom, floor boxes, etc…)

Uniformat

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A. Existing courtroom.

C1020 Interior Doors EA N/A. Existing to remain.

C102007 Interior Door

Hardware

As

Req’d

Existing entry door hardware to remain. Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in

Appendix A.

C3010 Wall Finishes SF Keep existing wall paneling. Patch walls as required to accommodate new work. Re-upholster the East wall.

C3020 Floor Finishes SY 26-28 oz. broadloom carpet over carpet pad.

C3020 Floor Finishes LF N/A. Existing wood base to remain.

Joseph Chow & Associates, Inc. 8.0 - 106 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C3030 Ceiling Finishes SF To remain. Patch and repair as needed to accommodate new work. Fabric on soffits to be replaced with fabric to match existing.

D304007 Exhaust Systems MBH KW Modify HVAC system to accommodate the new rooms in the Hearing Room.

D4010 Fire Alarm and

Detection System

LF As

Required

N/A. Existing to remain.

D4040 Sprinkler

Systems

EA As

Required

N/A. Existing to remain.

D502001 Branch Wiring As

Req’d

Distributed convenience outlets, including provisions for cleaning equipment/motor loads.

Coordinate electrical requirements with the AV designer, USMS, ALS system, and court staff.

Conduit and boxes for a loudspeaker sound system.

Provide power for wall mounted flat screen presentation monitor.

D502002 Lighting

Equipment

As

Req’d

N/A. Existing to remain.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

Provide conduit from Jury Assembly Room 740 to Room 790 to provide connectivity of audio and video between the two rooms.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 709.

Connect security infrastructure to this room as required.

Joseph Chow & Associates, Inc. 8.0 - 107 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

E1010 Commercial

Equipment

EA Video projector, media equipment, and retractable overhead screen and ceiling projector unit(s) will be provided by the Courts – FF & E.

Contractor to provide infrastructure only.

E202003 Freestanding

Furniture

EA Freestanding furniture. FF & E.

F2010 Building

Demolition

EA Remove existing spectator seating, spectator railing, jury box and judge’s bench. Salvage and store for future re-use.

Joseph Chow & Associates, Inc. 8.0 - 108 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

- Page Left Intentionally Blank -

Joseph Chow & Associates, Inc. 8.0 - 109 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

7.1.2 USDC Excuse Room – DELETED WORK SCOPE Option C

ROOMS: 746

Function/adjacencies: USDC: Excuse room.

Special Dimensions: N/A.

Access: Access from existing corridor.

Courts’ POR Reference: N/A.

Special Requirements:

Uniformat

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF N/A. Existing to remain.

C1020 Interior Doors EA N/A. Existing to remain.

C102007 Interior Door

Hardware

As

Req’d

N/A. Existing to remain.

C3010 Wall Finishes SF Remove existing wall covering and paint.

C3020 Floor Finishes SF 24” x 24” Carpet Tile

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF N/A. Existing to remain.

D304007 Exhaust Systems MBH KW N/A. Existing to remain.

D4010 Fire Alarm and

Detection System

LF As

Required

N/A. Existing to remain.

D4040 Sprinkler

Systems

EA As

Required

N/A. Existing to remain.

D502001 Branch Wiring As

Req’d

N/A. Existing to remain.

D502002 Lighting

Equipment

As

Req’d

N/A. Existing to remain.

D503001 Telecom. System N/A. Existing to remain.

E202003 Freestanding

EA Freestanding office furniture. FF & E.

Joseph Chow & Associates, Inc. 8.0 - 110 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Joseph Chow & Associates, Inc. 8.0 - 111 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

7.1.3 USDC Lactation Room – DELETED WORK SCOPE Option C

ROOMS: 744

Function/adjacencies: USDC: Lactation room.

Special Dimensions: N/A, Access: Access from the existing corridor.

Special Requirements: Apply opaque film over existing window to obscure the inside of the room from the corridor for privacy.

Uniformat

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF N/A. Existing to remain.

C1020 Interior Doors EA N/A. Existing to remain.

C102007 Interior Door

Hardware

As

Req’d

N/A. Existing to remain.

C3010 Wall Finishes SF Remove existing wall covering and paint.

C3020 Floor Finishes SF 24” x 24” Carpet Tile

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF N/A. Existing to remain.

D304007 Exhaust Systems MBH N/A. Existing to remain.

D4010 Fire Alarm and

Detection System

LF N/A. Existing to remain.

D4040 Sprinkler

Systems

EA N/A. Existing to remain.

D502001 Branch Wiring As

Req’d

N/A. Existing to remain.

D502002 Lighting

Equipment

As

Req’d

N/A. Existing to remain.

D503001 Telecom. System N/A. Existing to remain.

Joseph Chow & Associates, Inc. 8.0 - 112 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 113 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

7.1.4 USDC Jury Lounge – DELETED WORK SCOPE Option C

Room: 741

Function/adjacencies: USDC: Jury Lounge.

Access: Access from the Vestibule.

Special Requirements: Existing counter and sink to remain.

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A. Existing to remain.

C1020 Interior Doors EA N/A. Existing to remain.

C102007 Interior Door

Hardware

As

Req’d

Building standard.

C3010 Wall Finishes SF Remove existing wall covering and paint.

C3020 Floor Finishes SF 24” x 24” Carpet Tile

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF N/A. Existing to remain.

D304007 Exhaust Systems MBH N/A. Existing to remain.

D4010 Fire Alarm and

Detection System

LF N/A. Existing to remain.

D4040 Sprinkler

Systems

EA N/A. Existing to remain.

D502001 Branch Wiring As

Req’d

N/A. Existing to remain.

D502002 Lighting

Equipment

As

Req’d

N/A. Existing to remain.

D503001 Telecom. System EA N/A. Existing to remain.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 114 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Joseph Chow & Associates, Inc. 8.0 - 115 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

7.1.5 USDC Jury Toilet Rooms – DELETED WORK SCOPE Option C

ROOMS: 741-01, 741-02

Function/adjacencies: USDC: Jury Restrooms (Men’s and Women’s)

Access: Access from the Jury Lounge.

Special Requirements:

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF N/A. Existing to remain.

C1020 Interior Doors EA N/A. Existing to remain.

C102007 Interior Door

Hardware

As

Req’d

N/A. Existing to remain.

C103002 Toilet

Accessories

EA N/A. Existing to remain.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF N/A. Existing to remain. Clean.

C3020 Floor Finishes LF N/A. Existing to remain. Clean.

C3030 Ceiling Finishes SF N/A. Existing to remain.

D2010 Plumbing

Fixtures

EA N/A. Existing to remain.

D304007 Exhaust Systems MBH N/A. Existing to remain.

D4010 Fire Alarm and

Detection System

LF N/A. Existing to remain.

D4040 Sprinkler

Systems

EA N/A. Existing to remain.

D502001 Branch Wiring As

Req’d

N/A. Existing to remain.

Joseph Chow & Associates, Inc. 8.0 - 116 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502002 Lighting

Equipment

As

Req’d

N/A. Existing to remain.