Roybal_DB_RFP_Amendment_04_10th_Fl_Room_Reqs.pdf

PDF 1 MB Posted

Attached to
Edward R. Roybal Repair and Alteration Tenant Improvement Prospectus Project
Solicitation number
GS-09P-15-KT-C-0014
Issued by

About this file

10th Fl Room Requirements

View the file

Other files

File Type Posted
Roybal_DB_RFP_Amendment_06.pdf PDF
Roybal_DB_RFP_Amendment_05.pdf PDF
Roybal_DB_RFP_Amendment_04.pdf PDF
Roybal_DB_RFP_Amendment_04_14th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_6th_FL_room_reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_revised_bid_sheet.pdf PDF
Roybal_DB_RFP_Amendment_04_9th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_scope_reductions.pdf PDF
Roybal_DB_RFP_Amendment_04_16th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_8th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_15th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_7th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Certificate_of_Current_Cost_or_Pricing_Data_(1).pdf PDF
Roybal_DB_RFP_Amendment_03_SF30.pdf PDF
Roybal_DB_bid_sheet_Amendment_03.pdf PDF
Roybal_DB_RFP_PPQ_Amendment_02.docx DOCX document
Roybal_DB_bid_sheet_Amendment_02.pdf PDF
Roybal_DB_RFP_Offeror_Representations_and_Certifications.doc DOC document
Roybal_DB_RFP_Amendment_02_SF30.pdf PDF
Roybal_DB_RFP_Amendment_01.pdf PDF
08_Roybal_room_requirements_Pg_117-138.pdf PDF
Roybal_Pre_proposal_Conference_Final_05_28_2015_(1).pdf PDF
Appendix_C_Roybal_Swing_Space_Requirements_and_Move_Matrix_04_06_2015.pdf PDF
Roybal_Fed_Bldg_BER_Final_Submittal.pdf PDF
Roybal_Fed_Bldg_BER_Final_Submittal_Appendices.pdf PDF
AmendmenttoAppendixCSwingSpaceandMovesSOWFinal.doc.pdf PDF
Roybal_DB_RFP_preproposal_attendees.pdf PDF
Volume_3_-_References.pdf PDF
Past_Performance_Questionnaire.docx DOCX document
Volume_2B_Roybal_PDS_and_Appendix.pdf PDF
VOLUME_2A_SCOPE_OF_WORK.pdf PDF
Roybal_DB_1442.pdf PDF
Roybal_DB_RFP_Agreement.pdf PDF
Roybal_DB_Division_1.pdf PDF
Roybal_DB_Solicitation.pdf PDF
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

United States General Service Administration

PROGRAM DEVELOPMENT STUDY – FINAL SUBMITTAL

Edward R. Roybal Federal Building and U.S. Courthouse 8.0 IMPLEMENTATION PLAN

Joseph Chow & Associates, Inc. 8.0 - 185 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Do not remove this notice. Properly destroy documents when no longer required

ROOM REQUIREMENTS

The Room Requirements tables below represent preliminary information from the User describing general requirements. During the design process, the Design/Build Contractor shall work with the Users to confirm the room requirements and effectively utilize the maximum allowable space.

10.1 TENTH FLOOR – USBC ADMINSTRATIVE SERIVCIES OSD

10.1.1 USBC OSD Open Office

ROOMS: 1032-01, 1032-06

Space Characteristics

Function/adjacencies: USBC OSD: Open Work Area.

Special Dimensions: Provide 9’-0” min. ceiling height.

Access: Access is from the existing building corridor.

Courts’ POR Reference: 5.2.3

Special Requirements:

Uniformat

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A. Open office area.

C1020 Interior Doors EA N/A

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in Appendix A.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

LF As

Required

Joseph Chow & Associates, Inc. 8.0 - 186 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D4040 Sprinkler

Systems

EA As

D502001 Branch Wiring As

Req’d

One quadruplex outlet (per cubicle), Outlets/feeds to powered furniture panel as required.

One isolated ground duplex outlet (per cubicle).

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 1009.

Connect security infrastructure to this room as required.

E202002 Modular

Prefabricated

Furniture

EA Mid height, modular furniture open workstation.

FF & E.

Joseph Chow & Associates, Inc. 8.0 - 187 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.1.2 10 th

Floor Break Room

ROOM: 1032-02

Function/adjacencies: 10 th Floor Break Room.

Access: Access from Open Office.

Courts’ POR Reference: 5.6.1

Special Requirements: Design an area for recycle bins.

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A. Existing walls.

C1020 Interior Doors EA N/A

C102007 Interior Door

Hardware

As

Req’d

N/A

C103002 Break Room

Accessories

EA Provide ABAAS compliant liquid soap dispenser and paper towel dispenser.

C103008 Counters LF Plastic laminate. 72” long minimum. Counter to be 24” deep with 4” high back and side splashes.

Cut out counter to accommodate drop in sink.

C103009 Cabinets LF ABAAS compliant millwork plastic laminate on all exposed surfaces. Space to be provided for separate, tenant supplied stand-alone refrigerator.

Under counter built-in microwave compartment.

Provide cabinets and drawers below counter and overhead cabinets.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF Vinyl Composition Tile (VCT).

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

Joseph Chow & Associates, Inc. 8.0 - 188 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D2010 Plumbing

Fixtures

EA One ABAAS compliant stainless steel sink (with garbage disposal) with gooseneck faucet, hot and cold lever handles. Provide plastic cold water line to Icemaker in refrigerator.

D304007 Exhaust Systems MBH KW Provide adequate HVAC with exhaust fans.

HVAC system shall adequate remove strong cooking smells.

D4010 Fire Alarm and

Detection System

D4040 Sprinkler

Systems

Six dedicated GFI duplex outlets. Three at counter, one for refrigerator, one below cabinet for build-in microwave and one switched for garbage disposal. Install switch at countertop near sink.

Two isolated ground outlets.

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

Separately switched fluorescent fixtures and under cabinet fluorescent lighting.

D503001 Telecom. System EA One wall phone outlet, one CATV outlet.

Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

Joseph Chow & Associates, Inc. 8.0 - 189 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.1.3 USBC OSD Supply Storage

ROOM: 1032-03

Function/adjacencies: USBC OSD: Supply Storage Area.

Courts’ POR Reference: 5.2.9

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type D - Drywall partition to 6” above

ACT ceiling – no insulation.

C1020 Interior Doors EA Building standard.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in Appendix A.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF Vinyl Composition Tile (VCT).

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including provisions for cleaning equipment/motor loads.

Duplex outlet(s), isolated ground- one minimum.

Joseph Chow & Associates, Inc. 8.0 - 190 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 1009.

Connect security infrastructure to this room as required.

E202003 Freestanding

Furniture

EA Freestanding furniture. Office furniture includes storage shelving/cabinets. Provide seismic restraints as required for the storage cabinets.

FF & E.

Joseph Chow & Associates, Inc. 8.0 - 191 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.1.4 USBC OSD Design Library

USBC OSD Storage

ROOM: 1032-04 1032-11

Function/adjacencies: USBC ODS: Design Library.

Access: Access is from the open office.

Courts’ POR Reference: 5.2.10

Special Requirements: Design to accommodate furniture/finishes design literature.

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A (within open office).

C1020 Interior Doors EA N/A.

C102007 Interior Door

Hardware

As

Req’d

N/A.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet Tile

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including provisions for cleaning equipment/motor loads.

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA N/A.

Joseph Chow & Associates, Inc. 8.0 - 192 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

E202003 Freestanding

Furniture

EA Freestanding furniture. FF & E.

Joseph Chow & Associates, Inc. 8.0 - 193 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.1.5 USBC OSD Manager’s Office

USBC Network and Developers Manager’s Office

ROOM: 1032-07 1032-10, 1037-09, 1037-10

Function/adjacencies: USBC OSD and Developers: Private office.

Access: Access is from the open office area.

Courts’ POR Reference: 5.2.1

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF Wall Type B - Ceiling height, demountable, modular furniture partition with custom panel width; transoms and borrowed lights should have the following:

Speech Intelligibility Index (STI) without sound system enhancement = 45.

N/A. Existing walls.

C1020 Interior Doors EA Standard as per demountable wall system.

N/A. Existing doors.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 194 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D4040 Sprinkler

Systems

Distributed convenience outlets, including

Min. one quadruplex receptacle (general use).

Duplex isolated ground outlet(s), two minimum.

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S.

Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

EA Freestanding office furniture. FF & E.

Joseph Chow & Associates, Inc. 8.0 - 195 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.1.6 USBC OSD’S Team Area and HR/Graphics

ROOMS: 1032-05, 1032-08 1058-06

Function/adjacencies: USBC: Share collaborative work space.

Access: Access is from the Open Office Areas.

Courts’ POR Reference: 5.6.8

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A. Existing walls.

C1020 Interior Doors EA N/A. Existing door.

C102007 Interior Door

Hardware

As

Req’d

N/A. Existing door hardware.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including

Duplex outlet(s), isolated ground – two minimum.

Joseph Chow & Associates, Inc. 8.0 - 196 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 197 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.1.7 USBC: ITD Help Desk Lab Work Area

ROOM: 1032-09

Function/adjacencies: USBC: ITD Help Desk Lab Work Area.

Access: Access is from the Open Office areas.

Courts’ POR Reference: 5.2.11

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF Wall Type B - Ceiling height, demountable, modular furniture partition with custom panel

C1020 Interior Doors EA Standard as per demountable wall system.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 198 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502001 Branch Wiring As

Req’d

Distributed convenience outlets, including

Min. three duplex outlets.

Provide electrical wire molding to support quad outlets on all walls at counter height. The outlets shall be every 3’-0” minimum.

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 199 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.1.8 USBC OSD Supervisor’s Office

ROOM: 1032-10 1032-07

Function/adjacencies: USBC OSD: Private Office.

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF Wall Type B - Ceiling height, demountable, modular furniture partition with custom panel

C1020 Interior Doors EA Standard as per demountable wall system.

C102007 Interior Door

Hardware

As

Req’d

Standard as per demounted wall system.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 200 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502001 Branch Wiring As

Req’d

Distributed convenience outlets, including

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 201 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.2 TENTH FLOOR – USBC MAIL AREA

10.2.1 USBC Mail Area

ROOM: 1034

Function/adjacencies: USBC: Mail Room.

Access: Access is from the existing corridor.

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type C - Drywall metal partition to 6" above ACT ceiling with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

C101005 Interior Windows EA Provide sliding window at transaction counter.

See example below of possible transaction window.

C1020 Interior Doors EA Building standard.

Provide cased opening from Mail Room to the

OSD File Storage Room 1032-03.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in Appendix A.

Joseph Chow & Associates, Inc. 8.0 - 202 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C103008 Counters LF Provide plastic laminate transaction counter.

Provide buzzer.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including

Min. three duplex outlets.

Provide buzzer to alert staff of person waiting to be helped.

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E101006 Teller and

Service

Equipment

EA Stainless steel pass through tray.

Joseph Chow & Associates, Inc. 8.0 - 203 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 1009.

Connect security infrastructure to this room as required.

E202003 Freestanding

Notes:

Joseph Chow & Associates, Inc. 8.0 - 204 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

- Page Left Intentionally Blank -

Joseph Chow & Associates, Inc. 8.0 - 205 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.3 TENTH FLOOR – USBC NETWORK | DEVELOPERS

10.3.1 USBC Network’s Open Office

ROOM: 1037-01

Function/adjacencies: USBC: Open Work Area.

Courts’ POR Reference: 5.2.4

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A. Open office area.

C1020 Interior Doors EA N/A

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in Appendix A.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 206 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502001 Branch Wiring As

Req’d

One quadruplex outlet (per cubicle), Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 1009.

Connect security infrastructure to this room as required.

E202002 Modular

Prefabricated

Furniture

EA Mid-height, demountable modular furniture partition. FF & E.

Joseph Chow & Associates, Inc. 8.0 - 207 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.3.2 USBC Developer’s OPEN OFFICE

ROOM: 1037-02

Function/adjacencies: USBC: Share collaborative work space.

Courts’ POR Reference: 5.6.8

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF N/A. Existing walls.

C1020 Interior Doors EA Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in Appendix A.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

Card reader to door leading to the Computer

Server Room and the Public Corridor.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 208 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502001 Branch Wiring As

Req’d

Distributed convenience outlets, including

One quadruplex outlet (per cubicle), Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 1009.

Connect security infrastructure to this room as required.

E202003 Freestanding

Furniture

Joseph Chow & Associates, Inc. 8.0 - 209 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.3.3 USBC Network | Developers General Storage

ROOM: 1037-03

Function/adjacencies: USBC: Shared open storage.

Access: Access is from the Team Area.

Courts’ POR Reference: 5.6.5

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF Wall Type A - Full height metal studs with slab to slab acoustically sealed drywall with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A.

C1020 Interior Doors EA Building standard.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in Appendix A.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

Joseph Chow & Associates, Inc. 8.0 - 210 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including

Duplex outlet(s), isolated ground- one minimum per storage area.

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 1009.

Connect security infrastructure to this room as

Joseph Chow & Associates, Inc. 8.0 - 211 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.3.4 USBC Network Manager’s Office

ROOMS: 1037-04, 1037-05, 1037-06

Function/adjacencies: USBC: Private office.

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF Wall Type B - Ceiling height, demountable, modular furniture partition with custom panel

C1020 Interior Doors EA Standard as per demountable wall system.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 212 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502001 Branch Wiring As

Req’d

Distributed convenience outlets, including

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 213 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.3.5 USBC Lab Work Area

ROOMS: 1037-07, 1037-08

Function/adjacencies: USBC: Lab work area.

Access: Access is from the Work Area.

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A. Existing walls.

C1020 Interior Doors EA N/A. Existing.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in Appendix A.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF Vinyl Composition Tile (VCT).

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 214 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502001 Branch Wiring As

Req’d

Distributed convenience outlets, including provisions for cleaning equipment/motor loads.

Min. three duplex outlets for each wall. Provide outlets waist high.

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 1009.

Connect security infrastructure to this room as required.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 215 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.4 TENTH FLOOR – USBC EXECUTIVE SUITE

10.4.1 USBC Executive Open Office

ROOM: 1050-01

Courts’ POR Reference: 5.1.5

Section

C101001 Fixed Partitions SF Some walls existing.

Wall Type A - Full height metal studs with slab to slab acoustically sealed drywall with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

Wall Type D - Drywall metal partition to 6" above ACT ceiling, no insulation.

C1020 Interior Doors EA N/A.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in Appendix A.

Joseph Chow & Associates, Inc. 8.0 - 216 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C3020 Floor Finishes SF 26-28 oz. broadloom carpet over carpet pad.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

One quadruplex outlet (per cubicle), Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 1009.

Connect security infrastructure to this room as required.

E202002 Modular

Prefabricated

Furniture

EA Mid-height, demountable modular furniture partition. FF & E.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 217 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.4.2 USBC Chief Deputy

ROOMS: 1050-02, 1050-03

Courts’ POR Reference: 5.1.3

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A. Existing walls.

C1020 Interior Doors EA N/A.

C102007 Interior Door

Hardware

As

Req’d

N/A. Existing.

C3010 Wall Finishes SF Wood chair rail with fabric wall covering above and below chair rail.

C3020 Floor Finishes SF 26-28 oz. broadloom carpet over carpet pad.

C3020 Floor Finishes LF 4” min. Solid, stain grade hardwood wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC with thermostat control.

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including

Joseph Chow & Associates, Inc. 8.0 - 218 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 219 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.4.3 USBC Conference Room

ROOM: 1050-04

Function/adjacencies: USBC: Conference Room.

Special Dimensions: Provide 10’-0” min. ceiling height.

Courts’ POR Reference: 5.1.1

Section

C101001 Fixed Partitions SF Some existing walls.

Where infilling existing door, infill with similar construction to existing walls assembly.

C1020 Interior Doors EA Hardwood veneer solid core door. Solid hardwood jambs, stops, and casings.

C102007 Interior Door

Hardware

As

Req’d

N/A. Existing.

C3010 Wall Finishes SF Wood chair rail with fabric wall covering above and below chair rail.

C3020 Floor Finishes SF 26-28 oz. broadloom carpet over carpet pad.

C3020 Floor Finishes LF 4” min. Solid, stain grade hardwood wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC with thermostat control.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 220 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502001 Branch Wiring As

Req’d

Distributed convenience outlets, including

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 221 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.4.4 USBC Clerk of the Court’s Office

ROOM: 1050-05

Courts’ POR Reference: 5.1.4

Special Requirements: Only work in the existing toilet shall be paint and to clean surfaces.

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A. Existing walls.

C1020 Interior Doors EA N/A.

C102007 Interior Door

Hardware

As

Req’d

N/A. Existing.

C3010 Wall Finishes SF Wood chair rail with fabric wall covering above and below chair rail.

C3020 Floor Finishes SF 26-28 oz. broadloom carpet over carpet pad.

C3020 Floor Finishes LF 4” min. Solid, stain grade hardwood wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC with thermostat control.

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including

Joseph Chow & Associates, Inc. 8.0 - 222 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 223 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.4.5 USBC Deputy in Charge’s Office

ROOM: 1050-06

Courts’ POR Reference: 5.1.3

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A. Existing walls.

C1020 Interior Doors EA N/A.

C102007 Interior Door

Hardware

As

Req’d

N/A. Existing.

C3010 Wall Finishes SF Wood chair rail with fabric wall covering above and below chair rail.

C3020 Floor Finishes SF 26-28 oz. broadloom carpet over carpet pad.

C3020 Floor Finishes LF 4” min. Solid, stain grade hardwood wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC with thermostat control.

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including

Joseph Chow & Associates, Inc. 8.0 - 224 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 225 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.4.6 USBC Work/Copy/Break Area

ROOM: 1050-07

Courts’ POR Reference: 5.1.6

Special Requirements: High Volume copy area

Medium volume copy are

Shredder

Shared printer area

Uniformat

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF N/A. Open office area.

C1020 Interior Doors EA N/A

C102007 Interior Door

Hardware

As

Req’d

N/A

C103008 Counters LF Plastic laminate. Up to 36” long maximum.

Counter to be 24” deep with 4” high back and side splashes. Cut out counter to accommodate drop in sink.

C103009 Cabinets LF ABAAS compliant millwork plastic laminate on all exposed surfaces. Provide cabinet and drawers below sink/counter.

D2010 Plumbing

Fixtures

EA One ABAAS compliant stainless steel sink with gooseneck faucet, hot and cold lever handles.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 26-28 oz. broadloom carpet over carpet pad.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

Joseph Chow & Associates, Inc. 8.0 - 226 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

One quadruplex outlet (per cubicle), Outlets/feeds to powered furniture panel as required. Distributed convenience outlets as required. Minimum one quadruplex outlet

(general purpose). Coordinate number of outlets and types with tenant-supplied equipment.

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Furniture

Freestanding office furniture. FF & E.

Joseph Chow & Associates, Inc. 8.0 - 227 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.5 TENTH FLOOR – USBC HUMAN RESOURCES (HR)

10.5.1 USBC HR Reception/Lobby

ROOM: 1058-01

Function/adjacencies: USBC: Reception/Lobby.

Courts’ POR Reference: 5.2.2

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF Wall Type A - Full height metal studs with slab to slab acoustically sealed drywall with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A.

C1020 Interior Doors EA Building standard.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in Appendix A.

C103008 Counters LF ADAAG compliant transaction counter. Provide break-resistant glazing at the transaction window per USCDG, Chapter 14.

Provide door buzzer.

Joseph Chow & Associates, Inc. 8.0 - 228 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Two duplex outlets in the waiting area. One quadruplex outlet at the transaction window counter.

Two isolated ground duplex outlet at the transaction window. Two isolated duplex outlets in public area.

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 1009.

Connect security infrastructure to this room as required.

E101006 Teller and

Service

Equipment

EA Stainless steel pass through tray.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 229 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.5.2 USBC HR Fingerprinting

ROOM: 1058-02

Function/adjacencies: USBC: Fingerprint Room.

Courts’ POR Reference: 5.2.7

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF Wall Type A - Full height metal studs with slab to slab acoustically sealed drywall with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A.

C1020 Interior Doors EA Building standard.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 230 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D4040 Sprinkler

Systems

Distributed convenience outlets, including

One isolated ground duplex outlet.

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 231 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.5.3 USBC Secured Storage

ROOM: 1058-03

Function/adjacencies: USBC: Secure storage room.

Courts’ POR Reference: 5.2.8

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF Wall Type E - Slab to slab wall construction, 3-

5/8” x 20 ga studs with 1 layer of 5/8” gypsum board. 9-Gauge steel or expanded metal mesh on inner side of partitions and above ceiling.

Security screen to be attached to floor slab and structure above and welded to all structural members and studs to form a contiguous barrier against entry.

C1020 Interior Doors EA Hollow metal and hollow metal frame.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF Vinyl Composition Tile (VCT).

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF Painted Gypsum Board.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 232 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502001 Branch Wiring As

Req’d

Distributed convenience outlets, including

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 233 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.5.4 USBC HR Conference Room

ROOM: 1058-04

Function/adjacencies: USBC: Conference Room.

Special Dimensions: Provide 10’-0” min. ceiling height.

Courts’ POR Reference: 5.2.5

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF Wall Type A - Full height metal studs with slab to slab acoustically sealed drywall with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A.

C1020 Interior Doors EA Building standard.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 234 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D4040 Sprinkler

Systems

Distributed convenience outlets, including provisions for cleaning equipment/motor loads.

Four GFI duplex outlets, four dedicated duplex outlet. Coordinate outlet types with tenant-supplied equipment.

Two isolated ground outlets and one MATV outlet. Provide conduit and outlet boxes for video conference system.

Provide floor outlet for power/data/phone to accommodate conference table.

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA One wall and floor phone outlet.

Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 235 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.5.5 USBC HR/Graphics Open Office

ROOM: 1058-05

Access: Access is from the reception/lobby.

Courts’ POR Reference: 5.2.3 and 5.2.4

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A. Open office area.

C1020 Interior Doors EA N/A

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in Appendix A.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

One quadruplex outlet (per cubicle), Joseph Chow & Associates, Inc. 8.0 - 236 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 1009.

Connect security infrastructure to this room as required.

E202002 Modular

Prefabricated

Furniture

Joseph Chow & Associates, Inc. 8.0 - 237 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.6 TENTH FLOOR – USBC A&I | FISCAL | PROCUREMENT (AFP)

10.6.1 AFP Open Office

ROOM: 1067-01, 1067-08

Courts’ POR Reference: 5.2.3 and 5.2.4

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A. Open office area.

C1020 Interior Doors EA N/A

C102007 Interior Door

Hardware

As

Req’d

N/A

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

One quadruplex outlet (per cubicle), Joseph Chow & Associates, Inc. 8.0 - 238 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

E202002 Modular

Prefabricated

Furniture

EA Mid-height, demountable modular furniture partition. FF & E.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 239 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

10.6.2 USBC AFP Manager’s, Graphics and HR Office

ROOMS: 1067-02, 1067-03, 1067-04, 1067-05, 1067-06, 1067-07, 1058-07

Special Requirements: Due to potential staff changes the Court will review the quantity of offices before the final plan is approved during the Design Phase of the project.

Uniformat

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF Wall Type B - Ceiling height, demountable, modular furniture partition with custom panel

EXCEPTION: N/A to 1067-02, 1067-03, and

1058-07 have existing walls.

C1020 Interior Doors EA Standard as per demountable wall system.

EXCEPTION: N/A to 1067-02, 1067-03, and

1058-07 that have existing door.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Suspended acoustical ceiling tiles and grid.

D304007 Exhaust Systems MBH KW Provide adequate HVAC.

D4010 Fire Alarm and

Detection System

Joseph Chow & Associates, Inc. 8.0 - 240 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D4040 Sprinkler

Systems

Distributed convenience outlets, including

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom.