Roybal_DB_RFP_Amendment_04_6th_FL_room_reqs.pdf

PDF 614 KB Posted

Attached to
Edward R. Roybal Repair and Alteration Tenant Improvement Prospectus Project
Solicitation number
GS-09P-15-KT-C-0014
Issued by

About this file

6th Fl Room Requirements

View the file

Other files

File Type Posted
Roybal_DB_RFP_Amendment_06.pdf PDF
Roybal_DB_RFP_Amendment_05.pdf PDF
Roybal_DB_RFP_Amendment_04.pdf PDF
Roybal_DB_RFP_Amendment_04_14th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_revised_bid_sheet.pdf PDF
Roybal_DB_RFP_Amendment_04_9th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_scope_reductions.pdf PDF
Roybal_DB_RFP_Amendment_04_16th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_8th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_15th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_10th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Amendment_04_7th_Fl_Room_Reqs.pdf PDF
Roybal_DB_RFP_Certificate_of_Current_Cost_or_Pricing_Data_(1).pdf PDF
Roybal_DB_RFP_Amendment_03_SF30.pdf PDF
Roybal_DB_bid_sheet_Amendment_03.pdf PDF
Roybal_DB_RFP_PPQ_Amendment_02.docx DOCX document
Roybal_DB_bid_sheet_Amendment_02.pdf PDF
Roybal_DB_RFP_Offeror_Representations_and_Certifications.doc DOC document
Roybal_DB_RFP_Amendment_02_SF30.pdf PDF
Roybal_DB_RFP_Amendment_01.pdf PDF
08_Roybal_room_requirements_Pg_117-138.pdf PDF
Roybal_Pre_proposal_Conference_Final_05_28_2015_(1).pdf PDF
Appendix_C_Roybal_Swing_Space_Requirements_and_Move_Matrix_04_06_2015.pdf PDF
Roybal_Fed_Bldg_BER_Final_Submittal.pdf PDF
Roybal_Fed_Bldg_BER_Final_Submittal_Appendices.pdf PDF
AmendmenttoAppendixCSwingSpaceandMovesSOWFinal.doc.pdf PDF
Roybal_DB_RFP_preproposal_attendees.pdf PDF
Volume_3_-_References.pdf PDF
Past_Performance_Questionnaire.docx DOCX document
Volume_2B_Roybal_PDS_and_Appendix.pdf PDF
VOLUME_2A_SCOPE_OF_WORK.pdf PDF
Roybal_DB_1442.pdf PDF
Roybal_DB_RFP_Agreement.pdf PDF
Roybal_DB_Division_1.pdf PDF
Roybal_DB_Solicitation.pdf PDF
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

United States General Service Administration

PROGRAM DEVELOPMENT STUDY – FINAL SUBMITTAL

Edward R. Roybal Federal Building and U.S. Courthouse 8.0 IMPLEMENTATION PLAN

Joseph Chow & Associates, Inc. 8.0 - 75 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Do not remove this notice. Properly destroy documents when no longer required

ROOM REQUIREMENTS

The Room Requirements tables below represent preliminary information from the User describing general requirements. During the design process, the Design/Build Contractor shall work with the Users to confirm the room requirements and effectively utilize the maximum allowable space.

6.1 SIXTH FLOOR – USDC GRAND JURY HEARING ROOM

6.1.1 USDC Grand Jury Hearing Room

ROOM: 650

Space Characteristics

Function/adjacencies: USDC: Grand Jury Hearing Room.

Special Dimensions: Existing.

Access: Existing.

Courts’ POR Reference: 4.2.1

Special Requirements: An existing and repurposed USDC courtroom will be used for this space.

Verify specific infrastructure requirements with the court (i.e. electrical, telecom, floor boxes, etc.)

Uniformat

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A. Existing courtroom.

C1020 Interior Doors EA N/A. Existing to remain.

C102007 Interior Door

Hardware

As

Req’d

Existing entry door hardware to remain. Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in

Appendix A.

C3010 Wall Finishes SF Keep existing wall paneling. Patch walls as required to accommodate new work. Re-upholster West wall.

C3020 Floor Finishes SY 26-28 oz. broadloom carpet over carpet pad.

C3020 Floor Finishes LF 4” min. N/A. Wood base to remain. Provide new wood base as needed to accommodate new construction.

Joseph Chow & Associates, Inc. 8.0 - 76 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C3030 Ceiling Finishes SF To remain. Patch and repair as needed to accommodate new work. Fabric on soffits to be replaced with fabric to match existing.

D304007 Exhaust Systems MBH N/A. Existing to remain.

D4010 Fire Alarm and

Detection System

LF N/A. Existing to remain.

D4040 Sprinkler

Systems

EA N/A. Existing to remain.

D502001 Branch Wiring As

Req’d

Distributed convenience outlets, including provisions for cleaning equipment/motor loads.

Coordinate electrical requirements with the AV designer, USMS, ALS system, and court staff.

Multiple isolated ground outlets (as required) for sound, ALS, data, telecommunication and video recording and presentation equipment as per court direction. Conduit and boxes for a loudspeaker sound system allowing audio inputs from video or other projection equipment. One

MATV outlet. Provide conduit and outlet boxes for video conferencing system. Provide conduit pathway to A/V closet.

Floor boxes shall be flush mounted with carpet covered or metal inserts. Provide connections for voice, data, and power within the floor box below the surface of the floor. Provide power for wall mounted flat screen presentation monitor.

Electrical outlets or junction boxes will be required at the U.S. Attorney station, grand jury forepersons and secretary stations, court report station, jury and witness boxes judge’s bench, jury box, and witness stand.

D502002 Lighting

Equipment

As

Req’d

N/A. Existing to remain.

Joseph Chow & Associates, Inc. 8.0 - 77 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 609.

Connect security infrastructure to this room as required.

E1010 Commercial

Equipment

EA Video projector, media equipment, and retractable overhead screen and ceiling projector unit(s) will be provided by the Courts – FF & E.

Contractor to provide infrastructure only.

E202003 Freestanding

Furniture

EA Freestanding furniture. FF & E.

F2010 Building

Demolition

EA Remove existing spectator seating, spectator railing, and jury box. Salvage and store spectator seating for future re-use. Judge’s bench to remain.

Joseph Chow & Associates, Inc. 8.0 - 78 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

- Page Left Intentionally Blank -

Joseph Chow & Associates, Inc. 8.0 - 79 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

6.1.2 USDC Security

ROOMS: 650-01

Function/adjacencies: USDC: Security.

Special Dimensions: N/A.

Access: Access from existing corridor.

Courts’ POR Reference: N/A.

Special Requirements:

Uniformat

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF N/A. Existing to remain.

C1020 Interior Doors EA N/A. Existing to remain.

C102007 Interior Door

Hardware

As

Req’d

N/A. Existing to remain.

C3010 Wall Finishes SF N/A. Existing to remain.

C3020 Floor Finishes SF N/A. Existing to remain.

C3020 Floor Finishes LF N/A. Existing to remain.

C3030 Ceiling Finishes SF N/A. Existing to remain.

D304007 Exhaust Systems MBH N/A. Existing to remain.

D4010 Fire Alarm and

Detection System

LF N/A. Existing to remain.

D4040 Sprinkler

Systems

EA N/A. Existing to remain.

D502001 Branch Wiring As

Req’d

Distributed convenience outlets, including

Min. one quadriplex receptacle (general use).

Duplex outlet(s), isolated ground- two minimum.

D502002 Lighting

Equipment

As

Joseph Chow & Associates, Inc. 8.0 - 80 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D503001 Telecom. System Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 609.

Connect security infrastructure to this room as required.

E202003 Freestanding

EA Freestanding office furniture. FF & E.

Joseph Chow & Associates, Inc. 8.0 - 81 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

6.1.3 USDC Vestibule – Base Scope of Work Option B

Room: 657

Function/adjacencies: USDC: Vestibule.

Special Dimensions: Provide 9’-0” min. ceiling height.

Access: Access from the Sallyport.

Special Requirements: A portion of work in this room shall be completed as part of the BASE

SCOPE OF WORK.

Uniformat

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A. Existing to remain.

C1020 Interior Doors EA Building standard. Provide a new door from the

Sallyport to the Vestibule and from the Vestibule into the Jury Lounge.

Existing door leading to the secure corridor shall be locked in place – COMPLETED UNDER

BASE SCOPE OF WORK

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF N/A. Existing to remain.

C3020 Floor Finishes LF N/A. Existing to remain.

C3030 Ceiling Finishes SF N/A. Existing to remain.

D304007 Exhaust Systems MBH N/A. Existing to remain.

D4010 Fire Alarm and

Detection System

LF N/A. Existing to remain.

D4040 Sprinkler

Systems

EA N/A. Existing to remain.

Joseph Chow & Associates, Inc. 8.0 - 82 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502001 Branch Wiring As

Req’d

N/A. Existing to remain.

D502002 Lighting

Equipment

As

Req’d

N/A. Existing to remain.

D503001 Telecom. System EA N/A. Existing to remain.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 83 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

6.1.4 USDC Witness Room – Option B DELETED WORK SCOPE

ROOMS: 651, 652

Function/adjacencies: USDC: Witness room.

Access: Access from existing corridor.

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF N/A. Existing to remain.

C1020 Interior Doors EA N/A. Existing to remain.

C102007 Interior Door

Hardware

As

Req’d

N/A. Existing to remain.

C3010 Wall Finishes SF Remove existing wall covering and paint.

C3020 Floor Finishes SF 24” x 24” Carpet Tile

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF N/A. Existing to remain.

D304007 Exhaust Systems MBH N/A. Existing to remain.

D4010 Fire Alarm and

Detection System

LF N/A. Existing to remain.

D4040 Sprinkler

Systems

EA N/A. Existing to remain.

D502001 Branch Wiring As

Req’d

N/A. Existing to remain.

D502002 Lighting

Equipment

As

Req’d

N/A. Existing to remain.

D503001 Telecom. System N/A. Existing to remain.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 84 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Joseph Chow & Associates, Inc. 8.0 - 85 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

6.1.5 USDC Conference Room

ROOMS: 658

Function/adjacencies: USDC: Conference room.

Access: Access from the Grand Jury Hearing Room vestibule.

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF N/A. Existing to remain.

C1020 Interior Doors EA N/A. Existing to remain.

C102007 Interior Door

Hardware

As

Req’d

N/A. Existing to remain.

C3010 Wall Finishes SF N/A. Existing to remain.

C3020 Floor Finishes SF 24” x 24” Carpet Tile

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF N/A. Existing to remain.

D304007 Exhaust Systems MBH N/A. Existing to remain.

D4010 Fire Alarm and

Detection System

LF N/A. Existing to remain.

D4040 Sprinkler

Systems

EA N/A. Existing to remain.

D502001 Branch Wiring As

Req’d

N/A. Existing to remain.

D502002 Lighting

Equipment

As

Req’d

D503001 Telecom. System N/A. Existing to remain.

Joseph Chow & Associates, Inc. 8.0 - 86 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 609.

Connect security infrastructure to this room as required.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 87 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

6.1.6 USDC Jury Lounge – Base Scope of Work – Option B

Room: 653-01

Function/adjacencies: USDC: Jury Lounge.

Access: Access from the Vestibule.

Special Requirements: Existing counter and sink to remain. A portion of work in this room shall be completed as part of the BASE SCOPE OF WORK.

Uniformat

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A. Existing to remain.

C1020 Interior Doors EA N/A. Existing to remain.

Existing door leading to the secure corridor shall be locked in place – COMPLETED UNDER

BASE SCOPE OF WORK

C102007 Interior Door

Hardware

As

Req’d

N/A. Existing to remain.

C3010 Wall Finishes SF N/A. Existing to remain.

C3020 Floor Finishes SF 24” x 24” Carpet Tile

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF N/A. Existing to remain.

D304007 Exhaust Systems MBH N/A. Existing to remain.

D4010 Fire Alarm and

Detection System

LF N/A. Existing to remain.

D4040 Sprinkler

Systems

EA N/A. Existing to remain.

D502001 Branch Wiring As

Req’d

N/A. Existing to remain.

Joseph Chow & Associates, Inc. 8.0 - 88 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D502002 Lighting

Equipment

As

Req’d

N/A. Existing to remain.

D503001 Telecom. System EA N/A. Existing to remain.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 89 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

6.1.7 USDC Jury Toilet Rooms – DELETED WORK SCOPE Option B

ROOMS: 664-01, 664-02

Function/adjacencies: USDC: Jury Restrooms (Men’s and Women’s)

Access: Access from the Jury Lounge.

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF N/A. Existing to remain.

C1020 Interior Doors EA N/A. Existing to remain.

C102007 Interior Door

Hardware

As

Req’d

N/A. Existing to remain.

C103002 Toilet

Accessories

EA N/A. Existing to remain.

C3010 Wall Finishes SF Paint.

C3020 Floor Finishes SF N/A. Existing to remain. Clean.

C3030 Ceiling Finishes SF N/A. Existing to remain. Clean.

D2010 Plumbing

Fixtures

EA N/A. Existing to remain.

D304007 Exhaust Systems MBH N/A. Existing to remain.

D4010 Fire Alarm and

Detection System

LF N/A. Existing to remain.

D4040 Sprinkler

Systems

EA N/A. Existing to remain.

D502001 Branch Wiring As

Req’d

N/A. Existing to remain.

D502002 Lighting

Equipment

As

Req’d

Joseph Chow & Associates, Inc. 8.0 - 90 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Joseph Chow & Associates, Inc. 8.0 - 91 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

6.1.7 USDC Jury Lounge Closet – DELETED WORK SCOPE Option B

ROOM: 664-03

Function/adjacencies: USDC: Closet

Access: Access from the Jury Lounge.

Section Description Qty Size Specific Requirements

C101002 Fixed Partitions SF N/A. Existing to remain.

C1020 Interior Doors EA N/A. Existing to remain.

C102007 Interior Door

Hardware

As

Req’d

N/A. Existing to remain.

C3010 Wall Finishes SF N/A. Existing to remain.

C3020 Floor Finishes SF 24” x 24” Carpet tile.

C3020 Floor Finishes LF 4” Vinyl wall base.

C3030 Ceiling Finishes SF N/A. Existing to remain.

D502001 Branch Wiring As

Req’d

N/A. Existing to remain.

D502002 Lighting

Equipment

As

Joseph Chow & Associates, Inc. 8.0 - 92 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Joseph Chow & Associates, Inc. 8.0 - 93 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

6.2 SIXTH FLOOR – Circuit Library – Base scope of work Option A

6.2.1 Circuit Library – Option A

ROOM: 680-01

Function/adjacencies: USDC: Open library room.

Courts’ POR Reference: None.

Special Requirements: Coordinate layout of book shelves with the Courts.

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A. Existing to remain.

C1020 Interior Doors EA Existing to remain unless security hardware is required.

Refer to USMS door hardware requirements

Appendix A.

C102007 Interior Door

Hardware

As

Req’d

Existing entry door hardware to remain. Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in

Appendix A.

C3010 Wall Finishes SF Existing Courtroom. Patch, repair, and refinish, surfaces affected by demolition. Replace fabric wall panels and replace with new fabric wall covering or drywall.

C3020 Floor Finishes SF 24” x 24” Carpet Tile.

C3020 Floor Finishes LF 4” min. Existing wood base to remain. Add wood bse where needed after demolition of existing walls.

Joseph Chow & Associates, Inc. 8.0 - 94 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C3030 Ceiling Finishes SF Modify existing ceiling to accommodate new work. Keep existing ceiling intact as much as possible. Remove fabric ceiling panels and infill with acoustic ceiling tile or drywall.

D304007 Exhaust Systems MBH KW Building standard HVAC.

D4010 Fire Alarm and

Detection System

LF As

Required

D4040 Sprinkler

Systems

EA As

D502001 Branch Wiring As

Coordinate number of outlets and types with tenant supplied equipment in each work area.

Provide floor box at check in desk near library entry.

Provide normal power for full-size copier and shredder. (Copier and shredder shall be provided by the Courts – FF & E.)

Provide convenience outlets throughout space per code requirements.

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 609.

Connect security infrastructure to this room as required.

Joseph Chow & Associates, Inc. 8.0 - 95 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

E202003 Freestanding

Furniture

EA Freestanding office furniture. Relocate existing circuit library from the Temple Level to the 6 th floor. FF & E.

F2010 Building

Demolition

EA Remove existing spectator seating, spectator railing, and jury box. Salvage and store wood wall paneling from demolished wall, and spectator seating, and judge’s bench for future re-use. Judge’s bench to remain.

Joseph Chow & Associates, Inc. 8.0 - 96 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Joseph Chow & Associates, Inc. 8.0 - 97 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

6.2.2 Circuit Library Training/Conference/Break Room – Base scope of work Option A

ROOM: 682

Function/adjacencies: Circuit Library: Training/Conference/Break Room.

Access: From the Circuit Library.

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type C - Drywall metal partition to 6" above ACT ceiling with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

C1020 Interior Doors EA Building standard.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C101005 Interior Windows SF Provide tempered glass windows with hollow metal frame.

C103002 Break Room

Accessories

EA Provide ABAAS compliant liquid soap dispenser and paper towel dispenser.

C3010 Wall Finishes SF Paint new walls. Patch, repair, and refinish existing wall surfaces affected by demolition.

C103008 Counters LF Counter to be 24” deep with 4” high back and side splashes. Cut out counter to accommodate drop in sink.

Joseph Chow & Associates, Inc. 8.0 - 98 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C103009 Cabinets LF ABAAS compliant millwork plastic laminate on all exposed surfaces. Space to be provided for separate, tenant supplied stand-alone refrigerator.

Under counter built-in microwave compartment.

Provide cabinets and drawers below counter and overhead cabinets.

C3020 Floor Finishes SF Vinyl Composition Tile (VCT).

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF 24” x 48” Modify existing ceiling to accommodate new work. Keep existing ceiling intact as much as possible.

D2010 Plumbing

Fixtures

EA One ABAAS compliant stainless steel sink (with garbage disposal) with gooseneck faucet, hot and cold lever handles. Provide plastic cold water line to icemaker in refrigerator.

D304007 Exhaust Systems MBH KW Building standard HVAC.

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including

Provide GFIs at counter and floor box at conference table. Outlet for wall mounted TV.

D502002 Lighting

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

Provide data in floor box at conference table and date for wall mounted TV.

Joseph Chow & Associates, Inc. 8.0 - 99 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 609.

Connect security infrastructure to this room as required.

E202003 Freestanding

Furniture

EA Freestanding office furniture. Wall mounted television.

Joseph Chow & Associates, Inc. 8.0 - 100 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Joseph Chow & Associates, Inc. 8.0 - 101 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

6.2.3 Circuit Library Tech Room – Base scope of work Option A

ROOM: 686

Function/adjacencies: Circuit Library: Tech room.

Access: Access from Circuit Library.

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF Wall Type C - Drywall metal partition to 6" above ACT ceiling with soundproofing insulation to achieve the following:

Reverberation Time (RT) in seconds = 0.5 –

0.7

Background Noise Room Criterion (RC) curve = 30

Noise Isolation Class (NIC) in decibels = 55

Speech Intelligibility Index (STI) without sound system enhancement = N/A

C1020 Interior Doors EA Building standard.

C102007 Interior Door

Hardware

As

Req’d

Provide mechanical lockset. Coordinate door hardware type and function with the Users.

C101005 Interior Windows SF Provide tempered glass windows with hollow metal frame.

C103008 Counters LF ABAAS compliant millwork plastic laminate on all exposed surfaces. Counter to be 24” deep. A counter shall accommodate two workstations.

Counter shall provide basic cabinet storage and open wall hung open shelving above.

C3010 Wall Finishes SF Paint new walls. Patch, repair, and refinish existing wall surfaces affected by demolition.

C3020 Floor Finishes SF Vinyl Composition Tile (VCT).

Joseph Chow & Associates, Inc. 8.0 - 102 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF Modify existing ceiling to accommodate new work. Keep existing ceiling intact as much as possible.

D304007 Exhaust Systems MBH KW Building standard HVAC.

D4010 Fire Alarm and

Detection System

Distributed convenience outlets, including provisions for cleaning equipment/motor loads.

Coordinate number of outlets with the Courts equipment needs.

Duplex isolated ground outlet(s), two minimum.

Equipment

As

Req’d

Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 609.

Connect security infrastructure to this room as required.

E202003 Freestanding

Joseph Chow & Associates, Inc. 8.0 - 103 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

6.2.4 Circuit Library Offices – Base scope of work Option A

ROOM: 610, 627, 699

Function/adjacencies: Circuit Library: Private Offices.

Section Description Qty Size Specific Requirements

C101001 Fixed Partitions SF N/A. Existing to remain.

C1020 Interior Doors EA New full glazed door with wood frame. Design of door shall be compatible with adjacent spaces for Rooms 610 and 699 only.

Room 627 – reuse existing door.

C102007 Interior Door

Hardware

As

Req’d

Building standard.

C3010 Wall Finishes SF Remove existing wall covering. Paint.

C3020 Floor Finishes SF 24” x 24” Carpet Tile.

C3020 Floor Finishes LF 4” min. Vinyl wall base.

C3030 Ceiling Finishes SF N/A. Existing to remain.

D304007 Exhaust Systems MBH N/A. Existing to remain.

D4010 Fire Alarm and

Detection System

LF N/A. Existing to remain.

D4040 Sprinkler

Systems

EA N/A. Existing to remain.

D502001 Branch Wiring As

One convenience outlet on each wall.

Equipment

As

Req’d

Joseph Chow & Associates, Inc. 8.0 - 104 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY

Uniformat

Section Description Qty Size Specific Requirements

D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.

Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.

There shall be one data outlet per wall.

D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build

Contractor shall provide infrastructure to support

USMS security equipment. The existing security equipment room is located in Room 609.

Connect security infrastructure to this room as required.

E202003 Freestanding

File details come from the government source that posted it. Updated .