United States General Service Administration
PROGRAM DEVELOPMENT STUDY – FINAL SUBMITTAL
Edward R. Roybal Federal Building and U.S. Courthouse 8.0 IMPLEMENTATION PLAN
Joseph Chow & Associates, Inc. 8.0 - 391 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY
Do not remove this notice. Properly destroy documents when no longer required
ROOM REQUIREMENTS
The Room Requirements tables below represent preliminary information from the User describing general requirements. During the design process, the Design/Build Contractor shall work with the Users to confirm the room requirements and effectively utilize the maximum allowable space.
15.1 FIFTEENTH FLOOR – US BANKRUPTCY COURTS –
DELETED WORK SCOPE OPTION F and G
15.1.1 General Assembly Conference Room – Option G
ROOM: 1545
Space Characteristics
Function/adjacencies: Conference Room.
Special Dimensions: Existing. 11’-6” ceiling height.
Access: Existing.
Courts’ POR Reference: 5.6.10
Special Requirements: An existing, decommissioned USBC courtroom will be used for this space.
Verify specific infrastructure requirements with the court (i.e. electrical, telecom, floor boxes, etc…)
Uniformat
Section Description Qty Size Specific Requirements
C101001 Fixed Partitions SF N/A. Existing courtroom.
C1020 Interior Doors EA N/A. Existing.
C102007 Interior Door
Hardware
As
Req’d
Existing entry door hardware to remain. Provide mechanical lockset. Coordinate door hardware type and function with the Users. For additional door hardware, see USMS security drawings in
Appendix A.
C3010 Wall Finishes SF Keep existing wall paneling. Patch walls as required to accommodate new work.
C3020 Floor Finishes SF Install 26-28 oz. broadloom carpet over carpet pad upon removal of existing courtroom furniture and floor monuments.
PROGRAM DEVELOPMENT STUDY – 75% SUBMITTAL
Joseph Chow & Associates, Inc. 8.0 - 392 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY
Uniformat
Section Description Qty Size Specific Requirements
C3020 Floor Finishes LF Clean base. Patch and repair base damaged by construction.
C3030 Ceiling Finishes SF N/A. Existing.
D304007 Exhaust Systems MBH KW N/A. Existing.
D4010 Fire Alarm and
Detection System
LF N/A. Existing.
D4040 Sprinkler
Systems
EA As
Required
N/A. Existing.
D502001 Branch Wiring As
Req’d
Keep existing power. Add multiple isolated ground outlets (as required) for sound, ALS, data, telecommunication and video recording and presentation equipment as per court direction, if required.
D502002 Lighting
Equipment
As
Req’d
Keep existing lighting.
D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.
Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.
D503005 Security System EA Refer to locations of USMS required security equipment in Appendix A. Design/Build
Contractor shall provide infrastructure to support
USMS security equipment. The existing security equipment room is located in Room 1509.
Connect security infrastructure to this room as required.
F2010 Building
Demolition
EA Remove existing spectator seating, spectator railing, jury box and judge’s bench. Salvage and store for future re-use.
E1010 Commercial
Equipment
EA Video projector, media equipment, and retractable overhead screen and ceiling projector unit(s) will be provided by the Courts – FF & E.
Contractor to provide infrastructure only.
E202003 Freestanding
Furniture
EA Freestanding court furniture. FF & E.
Joseph Chow & Associates, Inc. 8.0 - 393 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY
Joseph Chow & Associates, Inc. 8.0 - 394 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY
15.1.2 Bankruptcy Courtroom – DELETED WORK SCOPE Option F
ROOM: 1539
Function/adjacencies: Courtroom.
Special Dimensions: Existing. 11’-6” ceiling height.
Access: Existing.
Courts’ POR Reference: 5.6.10
Special Requirements: An existing, decommissioned USBC courtroom will be used for this space.
Verify specific infrastructure requirements with the court (i.e. electrical, telecom, floor boxes, etc…)
Uniformat
Section Description Qty Size Specific Requirements
C101001 Fixed Partitions SF N/A. Existing courtroom.
C1020 Interior Doors EA N/A. Existing.
C102007 Interior Door
Hardware
As
Req’d
N/A. Existing.
C3010 Wall Finishes SF Keep existing wall paneling. Patch walls as required to accommodate new work.
C3020 Floor Finishes SF Install 26-28 oz. broadloom carpet over carpet pad upon removal of existing courtroom furniture and floor monuments.
C3020 Floor Finishes LF Clean base. Patch and repair base damaged by construction.
C3030 Ceiling Finishes SF N/A. Existing.
D304007 Exhaust Systems MBH KW N/A. Existing.
D4010 Fire Alarm and
Detection System
LF N/A. Existing.
D4040 Sprinkler
Systems
EA As
Required
N/A. Existing.
Joseph Chow & Associates, Inc. 8.0 - 395 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY
Uniformat
Section Description Qty Size Specific Requirements
D502001 Branch Wiring As
Req’d
Keep existing power. Add multiple isolated ground outlets (as required) for sound, ALS, data, telecommunication and video recording and presentation equipment as per court direction, if required.
D502002 Lighting
Equipment
As
Req’d
Provided lighting fixtures to meet the illumination levels required in the latest edition of the U.S. Courts Design Guide 2007.
D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.
Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.
F2010 Building
Demolition
EA Remove existing spectator seating, spectator railing, jury box and judge’s bench. Salvage and store for future re-use.
E1010 Commercial
Equipment
EA Video projector, media equipment, and retractable overhead screen and ceiling projector unit(s) will be provided by the Courts – FF & E.
Contractor to provide infrastructure only.
E202003 Freestanding
Furniture
EA Freestanding court furniture. FF & E.
Joseph Chow & Associates, Inc. 8.0 - 396 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY
15.2 FIFTEENTH FLOOR – US BANKRUPTCY COURTS
15.2.1 Data Closet
ROOM: 1508
Function/adjacencies: USBC: Data Closet.
Special Dimensions: None.
Access: Access from the building corridor.
Courts’ POR Reference: N/A
Special Requirements:
Uniformat
Section Description Qty Size Specific Requirements
C101001 Fixed Partitions SF N/A. Existing.
C1020 Interior Doors EA Building Standard.
C102007 Interior Door
Hardware
As
Req’d
Provide mechanical lockset. Coordinate door hardware type and function with the Users.
C3010 Wall Finishes SF Paint.
C3020 Floor Finishes SF 12” x 12” Vinyl Composition Tile (VCT). Patch existing floor where wall was removed.
C3020 Floor Finishes LF 4” min. Vinyl wall base.
C3030 Ceiling Finishes SF Exposed ceiling.
D304007 Exhaust Systems MBH KW 24 hour DX cooling systems will require condensate drains per the U.S. Courts Design
Guide 2007.
D4010 Fire Alarm and
Detection System
LF Provide as required.
D4040 Sprinkler
Systems
EA As
Required
Provide as required.
D502001 Branch Wiring As
Req’d
Provide as required for new equipment.
Coordinate with the Courts Telecommunication vendor for power.
Joseph Chow & Associates, Inc. 8.0 - 397 PROPERTY OF THE UNITED STATES GOVERNMENT – FOR OFFICE USE ONLY
Uniformat
Section Description Qty Size Specific Requirements
D503001 Telecom. System EA Provide infrastructure to support the telecommunications vendor hired by the Courts.
Infrastructure includes but is not limited to, conduit boxes, pull strings, cable trays, j-hooks, etc.