Atch_7_(L-1),_ELIN_Pricing_Template_(Rev2).xlsx

XLSX spreadsheet 52 KB Posted

Attached to
Paving Indefinite Delivery/Indefinite Quantity (ID/IQ) Contract Federal contract opportunity
Solicitation number
FA9301-16-R-0011
Issued by
Department of the Air Force Materiel Command Test Center

About this file

Atch 7, ELIN Pricing Template

View the file

Other files for this federal contract opportunity

Other files attached to Paving Indefinite Delivery/Indefinite Quantity (ID/IQ) Contract, newest first.
File Type Posted
Solicitation_FA9301-16-R-0011_Amendment_0003.pdf PDF
FA9301-16-R-0011_Questions_and_Answers_(Round_3_-_FINAL).pdf PDF
Atch_5_Wage_Determination_-_Kern_County_(Update_2).pdf PDF
Atch_10_(L-4),_Seed_Project_Pricing_Template_(Rev2).xlsx XLSX spreadsheet
Atch_8_(L-2),_Estimated_Workload_(Rev2).xlsx XLSX spreadsheet
FA9301-16-R-0011_Questions_and_Answers_(Round_2).pdf.pdf PDF
FA9301-16-R-0011_Amendment_0002.pdf PDF
Atch_9_(L-3)_Seed_Project_Statement_of_Work_(Revised).pdf PDF
FA9301-16-R-0011_Amendment_0001.pdf PDF
Atch_5_Wage_Determination_-_Kern_County_(Update).pdf PDF
Atch_10_(L-4)_Seed_Project_Pricing_Template_(Revised).xlsx XLSX spreadsheet
Atch_7_(L-1)_ELIN_Pricing_Template_(Revised).xlsx XLSX spreadsheet
FA9301-16-R-0011_Questions_and_Answers_-_Technical.pdf PDF
Atch_1_Basic_Contract_Statement_of_Work_(Revised).pdf PDF
Atch_9_(L-3)_Seed_Project_Statement_of_Work_(Revised).pdf PDF
Atch_8_(L-2)_Estimated_Workload_(Revised).xlsx XLSX spreadsheet
Atch_6_Wage_Determination_-_Los_Angeles_County_(Update).pdf PDF
4_-_Maintenance_Road_Markings.pdf PDF
11_-_Repair_Roads_1-30A_Test_Area_AFRL_.pdf PDF
6_-_Repair_Roads_at_South_Base_Compound.pdf PDF
7_-_Repair_Parking_Lot_at_Ridley_Building_1440.pdf PDF
9_-_Repair_Parking_Lot_at_Building_1400.pdf PDF
1_-_Repair_South_Lancaster_Blvd.pdf PDF
12_-_Spall_Repair_Pad_15_Post_Jobwalk.pdf PDF
8_-_Minor_Construction_Expand_Parking_Lot_at_Building_605.pdf PDF
3_-_Maint_Crack_and_Slurry_Seal_Airfield_Multi_Locations.pdf PDF
10_-_Repair_Roads_Base_wide_Rosamond.pdf PDF
5_-_Maintenance_Traffic_Control_Signs_Basewide.pdf PDF
2_-_Maint_Crack_Seal_and_Slurry_Seal_S_Lancaster_Blvd.pdf PDF
FA9301-16-R-0011_Questions_and_Answers_-_Contractual.pdf PDF
Pre-Proposal_Conference_Vendor_Sign-In_Sheet_30_Mar_2017.pdf PDF
Pre-Proposal_Conference_Briefing_Slides_30_Mar_2017.pdf PDF
Atch_11_(L-5)_Schedule_of_Material_Submittals_Template.xls XLS spreadsheet
Atch_14_(L-8)_Past_Performance_Questionnaire_(PPQ).pdf PDF
Atch_5_Wage_Determination_-_Kern_County.pdf PDF
Atch_10_(L-4)_Seed_Project_Pricing_Template.xlsx XLSX spreadsheet
Atch_15_(L-9)_Subcontractor_Teaming_Partner_Consent_Form.pdf PDF
Atch_12_(L-6)_Progress_Schedule_Template.xlsx XLSX spreadsheet
FA9301-16-R-0011_Paving_IDIQ_Solicitation_SF_1442.pdf PDF
Atch_4_Civil_Engineering_Provided_Plans.pdf PDF
Atch_6_Wage_Determination_-_Los_Angeles_County.pdf PDF
Atch_9_(L-3)_Seed_Project_Statement_of_Work.pdf PDF
Atch_13_(L-7)_Past_Performance_Information_Form_(PPIF).pdf PDF
Atch_7_(L-1)_ELIN_Pricing_Template.xlsx XLSX spreadsheet
Atch_1_Basic_Contract_Statement_of_Work.pdf PDF
Atch_3_Paving_Technical_Specifications.pdf PDF
Atch_2_2017_Edwards_AFB_Design_Standards.pdf PDF
Atch_8_(L-2)_Estimated_Workload.xlsx XLSX spreadsheet
Show all 48

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Year 1

FA9301-16-R-0011 PAVING ID/IQ SOLITICATION
EXHIBIT LINE ITEM NUMBER (ELIN) PRICING TEMPLATE
YEAR 1
Offeror Name:
ELINDESCRIPTIONUNIT OF MEASUREPROPOSED PRICE
Sub-Base Course
A0016'' of Sub-baseSY
A002Each added inch of Sub-baseSY
Subgrade Prep
A0036'' of Subgrade preparationSY
A004Each added inch of Subgrade preparationSY
Base Course
A0056'' of BaseSY
A006Each added inch of BaseSY
ACC Pavement
A007Each 3'' AC (64/28 Polymer Modified Mix)SY
A008Airfield Roadways, Each 3'' AC (64/28 Polymer Modified Mix, no RAP)SY
A009Airfield Shoulders, Each 3'' AC (64/28 Polymer Modified Mix, no RAP)SY
A00AEach Added Inch (64/28 Polymer Modified Mix)SY
A00BAirfield Roadways, Each Added Inch (64/28 Polymer Modified Mix, no RAP)SY
A00CAirfield Shoulders, Each Added Inch (64/28 Polymer Modified Mix, no RAP)SY
A00DAirfield, Each 3'' AC (64/28 Polymer Modified Mix, no RAP)SY
A00EAirfield, Each Added Inch (64/28 Polymer Modified Mix, no RAP)SY
Doweling and Saw Cutting
A00FDowelingEA
A00GSaw Cutting (New Concrete Only)LF
ACC Milling
A00HMill ACC, first inchSY
A00JMilling, each added inchSY
ACC Pulverizing
A00KPulverize ACC and incorporate on-site into base course, up to 6 inches of ACCSY
A00LPulverize ACC and incorporate on-site into base course, each additional inchSY
A00MPulverize ACC and dispose off-baseSY
A00NPulverize ACC and dispose off-base, each additional inchSY
Base and Sub-Base Reinforcement Measures
A00PCement Treated Soil Treatment @ 6% portland cement, top 8" inchesSY
Bituminous Surface Treatment
A00QSingle Coat TreatmentSY
A00RDouble Coat TreatmentSY
ACC Spray Applications
A00STack CoatSY
A00TFog SealsSY
A00UPrime CoatSY
A00VGSB-88 RejuvenatorSY
ACC Crack Seal
A00WACC Crack Seal, Wide Cracks (1'' to 4'')LF
A00XACC Crack Seal, Medium Cracks (1/2" to 1'')LF
A00YACC Crack Seal, Narrow Cracks (1/16" to 1/2'')LF
Slurry Seal
A00ZSingle Application, with Tack CoatSY
A010Single Application, without Tack CoatSY
ACC Patching
A011ACC Patch < 100SYSY
A012ACC Patch > 100SYSY
Roadway and Airfield Markings
A013Roadway Striping, with A/F Type 1 BeadsLF
A014Roadway Striping, with A/F Type 4 BeadsLF
A015Roadway MARKING REFLECTIVE with A/F Type 1 BeadsSF
A016Roadway MARKING REFLECTIVE with A/F Type 4 BeadsSF
A017Roadway Marking, Thermoplastic MaterialSF
A018Airfield Striping, 30" Line total - on Full-Width Black Background, with A/F Type 1 BeadsLF
A019Airfield Striping, 30" Line total - on Full-Width Black Background, with A/F Type 3 BeadsLF
A01AAirfield Markings, with A/F Type 1 BeadsSF
A01BAirfield Markings, with A/F Type 3 BeadsSF
A01CAirfield, Thermoplastic Material Airfield RatedSF
A01DNon-Lead-Based Paint RemovalSF
A01ETemporary Construction-use ReflectorsEA
A01FPermanent, Type D Two-Way Reflective MarkersEA
A01GPermanent, Type G One-Way ReflectorsEA
A01HRumble Strips, rubberized material purchased and installed post-constructionEA
A01JRumble Strips, created in ACC at constructionLF
Concrete Work
A01KReinforced PCC Airfield, 650 psi Flexural Strength (ASR Free Aggregate)CY
A01LUnreinforced PCC Airfield, 650 psi Flexural Strength (ASR Free Aggregate)CY
A01MPCC Roadway, Roadway UseCY
A01NReinforced Concrete Pad, Formed and Cast in-placeCY
A01PReinforced PCC Headwall, Formed and Cast-in-placeCY
A01QPCC Valley GuttersCF
A01RPCC SpandrelsCF
A01S6" Curb with 18" GutterLF
A01T6" Curb, Curb OnlyLF
A01USidewalks 6" thick, unreinforced, 5' wideLF
A01VADA Entrances/Exits, Constructed in Existing Sidewalks, including demolition and disposalEA
A01WCorner-Wide ADA Entrances/Exits, Constructed in Existing Sidewalks, including demolition and disposalEA
A01XADA Entrances/Exits, with new Sidewalk ConstructionEA
A01YCorner-Wide ADA Entrances/Exits, with new Sidewalk ConstructionEA
A01ZHandicap Ramp 1:12 Maximum, 5' wide, with handrail both sidesLF
A020PCC Crack Seal, Rout and Seal Includes all preparation and pressure-applied epoxy sealantLF
A021Spall Repair, PCC PavementSF
Culverts
A022Culvert, 30'' Remove OnlyLF
A023Culvert, 36'' Remove OnlyLF
A024Culvert, 30'' CMP Install Only including end treatmentLF
A025Culvert, 36'' CMP Install Only including end treatmentLF
A026Culvert, 24'' RCP Install Only including end treatmentLF
A027Culvert, 30'' RCP Install Only including end treatmentLF
A028Culvert, 36'' RCP Install Only including end treatmentLF
Handling of Government Furnished Material
A029Material TruckingTON/MI
A02AOn-Base Bulk Material Loading & UnloadingCY
A02BPlacement of government furnished base 6"SY
A02CEach added inch of government furnished base 1"-5"SY
A02DPlacement of government furnished Sub-base 6"SY
A02EEach added inch of goverment furnished Sub-baseSY
Professional and Speciality Services
A02FExploratory Drilling per hole, in earth or AC, each footEA
A02GExploratory Drilling, per hole, in rock or through PCC, each 6'' deepEA
A02HDrive Sample, Testing, and a ReportEA
A02JSoil Sampling, Testing, and a ReportEA
A02K2-Man Survey Team, In-Field Marking and Report (These items are for additional surveying, as required, above and beyond a standard paving project. Surveying incidental to a standard paving project is to be included in the line items associated with the standard paving project.)HR
A02LPot-holing for utilities (These items are for additional pot-holing, as required, above and beyond a standard paving project. Pot-holing incidental to a standard paving project is to be included in the line items associated with the standard paving project.)HR
A02MUnder-Roadway Tunneling for Utility Placement, up to 12" DiameterLF
Material Handling
A02NMaintenance and Reconstruction of SHOULDERS using existing on-site materials onlyLF
A02PMaintenance and reconstruction of ditches using existing, on-site materials onlyLF
A02QCommon ExcavationCY
A02RRock ExcavationCY
A02SExcavation of Unsuitable MaterialsCY
A02TOff-Base Material Disposal (all construction debris; not HAZMAT)CY
A02USelect Fill Material (includes Material and Installation)CY
A02VRaise or Lower Utility CoversEA
Gates, Walls, and Fencing
A02W8' Chain Link FenceLF
A02X3 Fencing Wire outriggersLF
A02Y8' Pedestrian GateLF
A02Z8' Rolling Vehicle GateLF
A0308' Vehicle Swing GateLF
A0318' Heavy-Duty Vehicle Swing GateLF
A032CMU wall, 2' High, split-face blockLF
A033Tortoise Fence, Erection and Removal per plan provided by EMLF
A034Construction of Protective Berms 95% compacted cohesive soil, 8" lifts, graded to smooth finishCY
A035K-RAILS, for use during construction, installation and removalLF
A036Reduced Height airfield barriers, for use during construction, installation and removalLF
Lights and Signage
A037New Installation of Regulatory and Warning Signs, including single postEA
A038Directional Signs, sign-face manufacture and installation on existing posts. Type III or Higher micro prismatic reflective sign panels. ASTM D4956-13 and AASHTO M 268-13.SF
A039Remove and Replace Standard Signs on existing posts. Type III or Higher micro prismatic reflective sign panels. ASTM D4956-13 and AASHTO M 268-13.EA
A03ASteel Breakaway Sign posts, 2" square, frangibly mounted up to 10' above grade. Anodized brown iaw the Edwards Base Design Standards. ASTM A653/A653M, ASTM A1011/A1011M, ASTM A123/A123M.EA
A03BTreated Wooden 8"x8" Sign Posts, up to 20' above grade Painted brown iaw the Edwards Base Design Standards. ASTM D4444, AWPA U1, AWPA.EA
A03CLighting or Utility Pole, breakaway, up to 40' above grade (To Include Alumin. Pole, One Arm Bracket, Up To 6' Deep Conc Base, Wire, and Conduit)EA
A03DSingle LED LuminaireEA
A03EDouble LED LuminaireEA
Joint Repair & Rubber Removal
A03FSilicone Joint RepairLF
A03GJet Fuel Resistant Joint Repair (DLA SS-S-200)LF
A03HCompression Joint SealLF
A03JAirfield Rubber Removal - WATERSF
Demolition
A03KDemo Curb and GutterLF
A03LDemo AsphaltCY
A03MDemo ConcreteCY
Guardrails and Barriers
A03NGuardrailsLF
A03PTL3 Energy Absorbing Barrier EndsEA
A03QTL2 Energy Absorbing Barrier EndsEA
A03RNon-Energy Absorbing Gating EndsEA
A03SEnergy Absorbing Barrels, Installed and FilledEA
A03TTemporary, Changeable Message Signage for Traffic ControlDAY
FOD Control
A03UManual FOD ControlHR
A03VMechanical FOD ControlHR
Non-Prepriced Items
A03WNon-Priced Item (To Be Negotiated Per Task Order)EA

&"Arial,Regular"&8FOR OFFICIAL USE ONLY Source Selection Sensitive Information See FAR 2.101 and 3.104

&"Arial,Regular"&8FA9301-16-R-0011 PAVING ID/IQ SOLICITATION

ATTACHMENT 7 (L-1)

ELIN PRICING TEMPLATE (YEAR 1) (REVISED 11 MAY 2017) &"Arial,Regular"&8FOR OFFICIAL USE ONLY Source Selection Sensitive Information See FAR 2.101 and 3.104

Year 2

FA9301-16-R-0011 PAVING ID/IQ SOLITICATION
EXHIBIT LINE ITEM NUMBER (ELIN) PRICING TEMPLATE
YEAR 2
Offeror Name:
ELINDESCRIPTIONUNIT OF MEASUREPROPOSED PRICE
Sub-Base Course
B0016'' of Sub-baseSY
B002Each added inch of Sub-baseSY
Subgrade Prep
B0036'' of Subgrade preparationSY
B004Each added inch of Subgrade preparationSY
Base Course
B0056'' of BaseSY
B006Each added inch of BaseSY
ACC Pavement
B007Each 3'' AC (64/28 Polymer Modified Mix)SY
B008Airfield Roadways, Each 3'' AC (64/28 Polymer Modified Mix, no RAP)SY
B009Airfield Shoulders, Each 3'' AC (64/28 Polymer Modified Mix, no RAP)SY
B00AEach Added Inch (64/28 Polymer Modified Mix)SY
B00BAirfield Roadways, Each Added Inch (64/28 Polymer Modified Mix, no RAP)SY
B00CAirfield Shoulders, Each Added Inch (64/28 Polymer Modified Mix, no RAP)SY
B00DAirfield, Each 3'' AC (64/28 Polymer Modified Mix, no RAP)SY
B00EAirfield, Each Added Inch (64/28 Polymer Modified Mix, no RAP)SY
Doweling and Saw Cutting
B00FDowelingEA
B00GSaw Cutting (New Concrete Only)LF
ACC Milling
B00HMill ACC, first inchSY
B00JMilling, each added inchSY
ACC Pulverizing
B00KPulverize ACC and incorporate on-site into base course, up to 6 inches of ACCSY
B00LPulverize ACC and incorporate on-site into base course, each additional inchSY
B00MPulverize ACC and dispose off-baseSY
B00NPulverize ACC and dispose off-base, each additional inchSY
Base and Sub-Base Reinforcement Measures
B00PCement Treated Soil Treatment @ 6% portland cement, top 8" inchesSY
Bituminous Surface Treatment
B00QSingle Coat TreatmentSY
B00RDouble Coat TreatmentSY
ACC Spray Applications
B00STack CoatSY
B00TFog SealsSY
B00UPrime CoatSY
B00VGSB-88 RejuvenatorSY
ACC Crack Seal
B00WACC Crack Seal, Wide Cracks (1'' to 4'')LF
B00XACC Crack Seal, Medium Cracks (1/2" to 1'')LF
B00YACC Crack Seal, Narrow Cracks (1/16" to 1/2'')LF
Slurry Seal
B00ZSingle Application, with Tack CoatSY
B010Single Application, without Tack CoatSY
ACC Patching
B011ACC Patch < 100SYSY
B012ACC Patch > 100SYSY
Roadway and Airfield Markings
B013Roadway Striping, with A/F Type 1 BeadsLF
B014Roadway Striping, with A/F Type 4 BeadsLF
B015Roadway MARKING REFLECTIVE with A/F Type 1 BeadsSF
B016Roadway MARKING REFLECTIVE with A/F Type 4 BeadsSF
B017Roadway Marking, Thermoplastic MaterialSF
B018Airfield Striping, 30" Line total - on Full-Width Black Background, with A/F Type 1 BeadsLF
B019Airfield Striping, 30" Line total - on Full-Width Black Background, with A/F Type 3 BeadsLF
B01AAirfield Markings, with A/F Type 1 BeadsSF
B01BAirfield Markings, with A/F Type 3 BeadsSF
B01CAirfield, Thermoplastic Material Airfield RatedSF
B01DNon-Lead-Based Paint RemovalSF
B01ETemporary Construction-use ReflectorsEA
B01FPermanent, Type D Two-Way Reflective MarkersEA
B01GPermanent, Type G One-Way ReflectorsEA
B01HRumble Strips, rubberized material purchased and installed post-constructionEA
B01JRumble Strips, created in ACC at constructionLF
Concrete Work
B01KReinforced PCC Airfield, 650 psi Flexural Strength (ASR Free Aggregate)CY
B01LUnreinforced PCC Airfield, 650 psi Flexural Strength (ASR Free Aggregate)CY
B01MPCC Roadway, Roadway UseCY
B01NReinforced Concrete Pad, Formed and Cast in-placeCY
B01PReinforced PCC Headwall, Formed and Cast-in-placeCY
B01QPCC Valley GuttersCF
B01RPCC SpandrelsCF
B01S6" Curb with 18" GutterLF
B01T6" Curb, Curb OnlyLF
B01USidewalks 6" thick, unreinforced, 5' wideLF
B01VADA Entrances/Exits, Constructed in Existing Sidewalks, including demolition and disposalEA
B01WCorner-Wide ADA Entrances/Exits, Constructed in Existing Sidewalks, including demolition and disposalEA
B01XADA Entrances/Exits, with new Sidewalk ConstructionEA
B01YCorner-Wide ADA Entrances/Exits, with new Sidewalk ConstructionEA
B01ZHandicap Ramp 1:12 Maximum, 5' wide, with handrail both sidesLF
B020PCC Crack Seal, Rout and Seal Includes all preparation and pressure-applied epoxy sealantLF
B021Spall Repair, PCC PavementSF
Culverts
B022Culvert, 30'' Remove OnlyLF
B023Culvert, 36'' Remove OnlyLF
B024Culvert, 30'' CMP Install Only including end treatmentLF
B025Culvert, 36'' CMP Install Only including end treatmentLF
B026Culvert, 24'' RCP Install Only including end treatmentLF
B027Culvert, 30'' RCP Install Only including end treatmentLF
B028Culvert, 36'' RCP Install Only including end treatmentLF
Handling of Government Furnished Material
B029Material TruckingTON/MI
B02AOn-Base Bulk Material Loading & UnloadingCY
B02BPlacement of government furnished base 6"SY
B02CEach added inch of government furnished base 1"-5"SY
B02DPlacement of government furnished Sub-base 6"SY
B02EEach added inch of goverment furnished Sub-baseSY
Professional and Speciality Services
B02FExploratory Drilling per hole, in earth or AC, each footEA
B02GExploratory Drilling, per hole, in rock or through PCC, each 6'' deepEA
B02HDrive Sample, Testing, and a ReportEA
B02JSoil Sampling, Testing, and a ReportEA
B02K2-Man Survey Team, In-Field Marking and Report (These items are for additional surveying, as required, above and beyond a standard paving project. Surveying incidental to a standard paving project is to be included in the line items associated with the standard paving project.)HR
B02LPot-holing for utilities (These items are for additional pot-holing, as required, above and beyond a standard paving project. Pot-holing incidental to a standard paving project is to be included in the line items associated with the standard paving project.)HR
B02MUnder-Roadway Tunneling for Utility Placement, up to 12" DiameterLF
Material Handling
B02NMaintenance and Reconstruction of SHOULDERS using existing on-site materials onlyLF
B02PMaintenance and reconstruction of ditches using existing, on-site materials onlyLF
B02QCommon ExcavationCY
B02RRock ExcavationCY
B02SExcavation of Unsuitable MaterialsCY
B02TOff-Base Material Disposal (all construction debris; not HAZMAT)CY
B02USelect Fill Material (includes Material and Installation)CY
B02VRaise or Lower Utility CoversEA
Gates, Walls, and Fencing
B02W8' Chain Link FenceLF
B02X3 Fencing Wire outriggersLF
B02Y8' Pedestrian GateLF
B02Z8' Rolling Vehicle GateLF
B0308' Vehicle Swing GateLF
B0318' Heavy-Duty Vehicle Swing GateLF
B032CMU wall, 2' High, split-face blockLF
B033Tortoise Fence, Erection and Removal per plan provided by EMLF
B034Construction of Protective Berms 95% compacted cohesive soil, 8" lifts, graded to smooth finishCY
B035K-RAILS, for use during construction, installation and removalLF
B036Reduced Height airfield barriers, for use during construction, installation and removalLF
Lights and Signage
B037New Installation of Regulatory and Warning Signs, including single postEA
B038Directional Signs, sign-face manufacture and installation on existing posts. Type III or Higher micro prismatic reflective sign panels. ASTM D4956-13 and AASHTO M 268-13.SF
B039Remove and Replace Standard Signs on existing posts. Type III or Higher micro prismatic reflective sign panels. ASTM D4956-13 and AASHTO M 268-13.EA
B03ASteel Breakaway Sign posts, 2" square, frangibly mounted up to 10' above grade. Anodized brown iaw the Edwards Base Design Standards. ASTM A653/A653M, ASTM A1011/A1011M, ASTM A123/A123M.EA
B03BTreated Wooden 8"x8" Sign Posts, up to 20' above grade Painted brown iaw the Edwards Base Design Standards. ASTM D4444, AWPA U1, AWPA.EA
B03CLighting or Utility Pole, breakaway, up to 40' above grade (To Include Alumin. Pole, One Arm Bracket, Up To 6' Deep Conc Base, Wire, and Conduit)EA
B03DSingle LED LuminaireEA
B03EDouble LED LuminaireEA
Joint Repair & Rubber Removal
B03FSilicone Joint RepairLF
B03GJet Fuel Resistant Joint Repair (DLA SS-S-200)LF
B03HCompression Joint SealLF
B03JAirfield Rubber Removal - WATERSF
Demolition
B03KDemo Curb and GutterLF
B03LDemo AsphaltCY
B03MDemo ConcreteCY
Guardrails and Barriers
B03NGuardrailsLF
B03PTL3 Energy Absorbing Barrier EndsEA
B03QTL2 Energy Absorbing Barrier EndsEA
B03RNon-Energy Absorbing Gating EndsEA
B03SEnergy Absorbing Barrels, Installed and FilledEA
B03TTemporary, Changeable Message Signage for Traffic ControlDAY
FOD Control
B03UManual FOD ControlHR
B03VMechanical FOD ControlHR
Non-Prepriced Items
B03WNon-Priced Item (To Be Negotiated Per Task Order)EA

&"Arial,Regular"&8FOR OFFICIAL USE ONLY Source Selection Sensitive Information See FAR 2.101 and 3.104

&"Arial,Regular"&8FA9301-16-R-0011 PAVING ID/IQ SOLICITATION

ATTACHMENT 7 (L-1)

ELIN PRICING TEMPLATE (YEAR 2) (REVISED 11 MAY 2017) &"Arial,Regular"&8FOR OFFICIAL USE ONLY

Year 3

FA9301-16-R-0011 PAVING ID/IQ SOLITICATION
EXHIBIT LINE ITEM NUMBER (ELIN) PRICING TEMPLATE
YEAR 3
Offeror Name:
ELINDESCRIPTIONUNIT OF MEASUREPROPOSED PRICE
Sub-Base Course
C0016'' of Sub-baseSY
C002Each added inch of Sub-baseSY
Subgrade Prep
C0036'' of Subgrade preparationSY
C004Each added inch of Subgrade preparationSY
Base Course
C0056'' of BaseSY
C006Each added inch of BaseSY
ACC Pavement
C007Each 3'' AC (64/28 Polymer Modified Mix)SY
C008Airfield Roadways, Each 3'' AC (64/28 Polymer Modified Mix, no RAP)SY
C009Airfield Shoulders, Each 3'' AC (64/28 Polymer Modified Mix, no RAP)SY
C00AEach Added Inch (64/28 Polymer Modified Mix)SY
C00BAirfield Roadways, Each Added Inch (64/28 Polymer Modified Mix, no RAP)SY
C00CAirfield Shoulders, Each Added Inch (64/28 Polymer Modified Mix, no RAP)SY
C00DAirfield, Each 3'' AC (64/28 Polymer Modified Mix, no RAP)SY
C00EAirfield, Each Added Inch (64/28 Polymer Modified Mix, no RAP)SY
Doweling and Saw Cutting
C00FDowelingEA
C00GSaw Cutting (New Concrete Only)LF
ACC Milling
C00HMill ACC, first inchSY
C00JMilling, each added inchSY
ACC Pulverizing
C00KPulverize ACC and incorporate on-site into base course, up to 6 inches of ACCSY
C00LPulverize ACC and incorporate on-site into base course, each additional inchSY
C00MPulverize ACC and dispose off-baseSY
C00NPulverize ACC and dispose off-base, each additional inchSY
Base and Sub-Base Reinforcement Measures
C00PCement Treated Soil Treatment @ 6% portland cement, top 8" inchesSY
Bituminous Surface Treatment
C00QSingle Coat TreatmentSY
C00RDouble Coat TreatmentSY
ACC Spray Applications
C00STack CoatSY
C00TFog SealsSY
C00UPrime CoatSY
C00VGSB-88 RejuvenatorSY
ACC Crack Seal
C00WACC Crack Seal, Wide Cracks (1'' to 4'')LF
C00XACC Crack Seal, Medium Cracks (1/2" to 1'')LF
C00YACC Crack Seal, Narrow Cracks (1/16" to 1/2'')LF
Slurry Seal
C00ZSingle Application, with Tack CoatSY
C010Single Application, without Tack CoatSY
ACC Patching
C011ACC Patch < 100SYSY
C012ACC Patch > 100SYSY
Roadway and Airfield Markings
C013Roadway Striping, with A/F Type 1 BeadsLF
C014Roadway Striping, with A/F Type 4 BeadsLF
C015Roadway MARKING REFLECTIVE with A/F Type 1 BeadsSF
C016Roadway MARKING REFLECTIVE with A/F Type 4 BeadsSF
C017Roadway Marking, Thermoplastic MaterialSF
C018Airfield Striping, 30" Line total - on Full-Width Black Background, with A/F Type 1 BeadsLF
C019Airfield Striping, 30" Line total - on Full-Width Black Background, with A/F Type 3 BeadsLF
C01AAirfield Markings, with A/F Type 1 BeadsSF
C01BAirfield Markings, with A/F Type 3 BeadsSF
C01CAirfield, Thermoplastic Material Airfield RatedSF
C01DNon-Lead-Based Paint RemovalSF
C01ETemporary Construction-use ReflectorsEA
C01FPermanent, Type D Two-Way Reflective MarkersEA
C01GPermanent, Type G One-Way ReflectorsEA
C01HRumble Strips, rubberized material purchased and installed post-constructionEA
C01JRumble Strips, created in ACC at constructionLF
Concrete Work
C01KReinforced PCC Airfield, 650 psi Flexural Strength (ASR Free Aggregate)CY
C01LUnreinforced PCC Airfield, 650 psi Flexural Strength (ASR Free Aggregate)CY
C01MPCC Roadway, Roadway UseCY
C01NReinforced Concrete Pad, Formed and Cast in-placeCY
C01PReinforced PCC Headwall, Formed and Cast-in-placeCY
C01QPCC Valley GuttersCF
C01RPCC SpandrelsCF
C01S6" Curb with 18" GutterLF
C01T6" Curb, Curb OnlyLF
C01USidewalks 6" thick, unreinforced, 5' wideLF
C01VADA Entrances/Exits, Constructed in Existing Sidewalks, including demolition and disposalEA
C01WCorner-Wide ADA Entrances/Exits, Constructed in Existing Sidewalks, including demolition and disposalEA
C01XADA Entrances/Exits, with new Sidewalk ConstructionEA
C01YCorner-Wide ADA Entrances/Exits, with new Sidewalk ConstructionEA
C01ZHandicap Ramp 1:12 Maximum, 5' wide, with handrail both sidesLF
C020PCC Crack Seal, Rout and Seal Includes all preparation and pressure-applied epoxy sealantLF
C021Spall Repair, PCC PavementSF
Culverts
C022Culvert, 30'' Remove OnlyLF
C023Culvert, 36'' Remove OnlyLF
C024Culvert, 30'' CMP Install Only including end treatmentLF
C025Culvert, 36'' CMP Install Only including end treatmentLF
C026Culvert, 24'' RCP Install Only including end treatmentLF
C027Culvert, 30'' RCP Install Only including end treatmentLF
C028Culvert, 36'' RCP Install Only including end treatmentLF
Handling of Government Furnished Material
C029Material TruckingTON/MI
C02AOn-Base Bulk Material Loading & UnloadingCY
C02BPlacement of government furnished base 6"SY
C02CEach added inch of government furnished base 1"-5"SY
C02DPlacement of government furnished Sub-base 6"SY
C02EEach added inch of goverment furnished Sub-baseSY
Professional and Speciality Services
C02FExploratory Drilling per hole, in earth or AC, each footEA
C02GExploratory Drilling, per hole, in rock or through PCC, each 6'' deepEA
C02HDrive Sample, Testing, and a ReportEA
C02JSoil Sampling, Testing, and a ReportEA
C02K2-Man Survey Team, In-Field Marking and Report (These items are for additional surveying, as required, above and beyond a standard paving project. Surveying incidental to a standard paving project is to be included in the line items associated with the standard paving project.)HR
C02LPot-holing for utilities (These items are for additional pot-holing, as required, above and beyond a standard paving project. Pot-holing incidental to a standard paving project is to be included in the line items associated with the standard paving project.)HR
C02MUnder-Roadway Tunneling for Utility Placement, up to 12" DiameterLF
Material Handling
C02NMaintenance and Reconstruction of SHOULDERS using existing on-site materials onlyLF
C02PMaintenance and reconstruction of ditches using existing, on-site materials onlyLF
C02QCommon ExcavationCY
C02RRock ExcavationCY
C02SExcavation of Unsuitable MaterialsCY
C02TOff-Base Material Disposal (all construction debris; not HAZMAT)CY
C02USelect Fill Material (includes Material and Installation)CY
C02VRaise or Lower Utility CoversEA
Gates, Walls, and Fencing
C02W8' Chain Link FenceLF
C02X3 Fencing Wire outriggersLF
C02Y8' Pedestrian GateLF
C02Z8' Rolling Vehicle GateLF
C0308' Vehicle Swing GateLF
C0318' Heavy-Duty Vehicle Swing GateLF
C032CMU wall, 2' High, split-face blockLF
C033Tortoise Fence, Erection and Removal per plan provided by EMLF
C034Construction of Protective Berms 95% compacted cohesive soil, 8" lifts, graded to smooth finishCY
C035K-RAILS, for use during construction, installation and removalLF
C036Reduced Height airfield barriers, for use during construction, installation and removalLF
Lights and Signage
C037New Installation of Regulatory and Warning Signs, including single postEA
C038Directional Signs, sign-face manufacture and installation on existing posts. Type III or Higher micro prismatic reflective sign panels. ASTM D4956-13 and AASHTO M 268-13.SF
C039Remove and Replace Standard Signs on existing posts. Type III or Higher micro prismatic reflective sign panels. ASTM D4956-13 and AASHTO M 268-13.EA
C03ASteel Breakaway Sign posts, 2" square, frangibly mounted up to 10' above grade. Anodized brown iaw the Edwards Base Design Standards. ASTM A653/A653M, ASTM A1011/A1011M, ASTM A123/A123M.EA
C03BTreated Wooden 8"x8" Sign Posts, up to 20' above grade Painted brown iaw the Edwards Base Design Standards. ASTM D4444, AWPA U1, AWPA.EA
C03CLighting or Utility Pole, breakaway, up to 40' above grade (To Include Alumin. Pole, One Arm Bracket, Up To 6' Deep Conc Base, Wire, and Conduit)EA
C03DSingle LED LuminaireEA
C03EDouble LED LuminaireEA
Joint Repair & Rubber Removal
C03FSilicone Joint RepairLF
C03GJet Fuel Resistant Joint Repair (DLA SS-S-200)LF
C03HCompression Joint SealLF
C03JAirfield Rubber Removal - WATERSF
Demolition
C03KDemo Curb and GutterLF
C03LDemo AsphaltCY
C03MDemo ConcreteCY
Guardrails and Barriers
C03NGuardrailsLF
C03PTL3 Energy Absorbing Barrier EndsEA
C03QTL2 Energy Absorbing Barrier EndsEA
C03RNon-Energy Absorbing Gating EndsEA
C03SEnergy Absorbing Barrels, Installed and FilledEA
C03TTemporary, Changeable Message Signage for Traffic ControlDAY
FOD Control
C03UManual FOD ControlHR
C03VMechanical FOD ControlHR
Non-Prepriced Items
C03WNon-Priced Item (To Be Negotiated Per Task Order)EA

&"Arial,Regular"&8FOR OFFICIAL USE ONLY Source Selection Sensitive Information See FAR 2.101 and 3.104

&"Arial,Regular"&8FA9301-16-R-0011 PAVING ID/IQ SOLICITATION

ATTACHMENT 7 (L-1)

ELIN PRICING TEMPLATE (YEAR 3) (REVISED 11 MAY 2017) &"Arial,Regular"&8FOR OFFICIAL USE ONLY

Year 4

FA9301-16-R-0011 PAVING ID/IQ SOLITICATION
EXHIBIT LINE ITEM NUMBER (ELIN) PRICING TEMPLATE
YEAR 4
Offeror Name:
ELINDESCRIPTIONUNIT OF MEASUREPROPOSED PRICE
Sub-Base Course
D0016'' of Sub-baseSY
D002Each added inch of Sub-baseSY
Subgrade Prep
D0036'' of Subgrade preparationSY
D004Each added inch of Subgrade preparationSY
Base Course
D0056'' of BaseSY
D006Each added inch of BaseSY
ACC Pavement
D007Each 3'' AC (64/28 Polymer Modified Mix)SY
D008Airfield Roadways, Each 3'' AC (64/28 Polymer Modified Mix, no RAP)SY
D009Airfield Shoulders, Each 3'' AC (64/28 Polymer Modified Mix, no RAP)SY
D00AEach Added Inch (64/28 Polymer Modified Mix)SY
D00BAirfield Roadways, Each Added Inch (64/28 Polymer Modified Mix, no RAP)SY
D00CAirfield Shoulders, Each Added Inch (64/28 Polymer Modified Mix, no RAP)SY
D00DAirfield, Each 3'' AC (64/28 Polymer Modified Mix, no RAP)SY
D00EAirfield, Each Added Inch (64/28 Polymer Modified Mix, no RAP)SY
Doweling and Saw Cutting
D00FDowelingEA
D00GSaw Cutting (New Concrete Only)LF
ACC Milling
D00HMill ACC, first inchSY
D00JMilling, each added inchSY
ACC Pulverizing
D00KPulverize ACC and incorporate on-site into base course, up to 6 inches of ACCSY
D00LPulverize ACC and incorporate on-site into base course, each additional inchSY
D00MPulverize ACC and dispose off-baseSY
D00NPulverize ACC and dispose off-base, each additional inchSY
Base and Sub-Base Reinforcement Measures
D00PCement Treated Soil Treatment @ 6% portland cement, top 8" inchesSY
Bituminous Surface Treatment
D00QSingle Coat TreatmentSY
D00RDouble Coat TreatmentSY
ACC Spray Applications
D00STack CoatSY
D00TFog SealsSY
D00UPrime CoatSY
D00VGSB-88 RejuvenatorSY
ACC Crack Seal
D00WACC Crack Seal, Wide Cracks (1'' to 4'')LF
D00XACC Crack Seal, Medium Cracks (1/2" to 1'')LF
D00YACC Crack Seal, Narrow Cracks (1/16" to 1/2'')LF
Slurry Seal
D00ZSingle Application, with Tack CoatSY
D010Single Application, without Tack CoatSY
ACC Patching
D011ACC Patch < 100SYSY
D012ACC Patch > 100SYSY
Roadway and Airfield Markings
D013Roadway Striping, with A/F Type 1 BeadsLF
D014Roadway Striping, with A/F Type 4 BeadsLF
D015Roadway MARKING REFLECTIVE with A/F Type 1 BeadsSF
D016Roadway MARKING REFLECTIVE with A/F Type 4 BeadsSF
D017Roadway Marking, Thermoplastic MaterialSF
D018Airfield Striping, 30" Line total - on Full-Width Black Background, with A/F Type 1 BeadsLF
D019Airfield Striping, 30" Line total - on Full-Width Black Background, with A/F Type 3 BeadsLF
D01AAirfield Markings, with A/F Type 1 BeadsSF
D01BAirfield Markings, with A/F Type 3 BeadsSF
D01CAirfield, Thermoplastic Material Airfield RatedSF
D01DNon-Lead-Based Paint RemovalSF
D01ETemporary Construction-use ReflectorsEA
D01FPermanent, Type D Two-Way Reflective MarkersEA
D01GPermanent, Type G One-Way ReflectorsEA
D01HRumble Strips, rubberized material purchased and installed post-constructionEA
D01JRumble Strips, created in ACC at constructionLF
Concrete Work
D01KReinforced PCC Airfield, 650 psi Flexural Strength (ASR Free Aggregate)CY
D01LUnreinforced PCC Airfield, 650 psi Flexural Strength (ASR Free Aggregate)CY
D01MPCC Roadway, Roadway UseCY
D01NReinforced Concrete Pad, Formed and Cast in-placeCY
D01PReinforced PCC Headwall, Formed and Cast-in-placeCY
D01QPCC Valley GuttersCF
D01RPCC SpandrelsCF
D01S6" Curb with 18" GutterLF
D01T6" Curb, Curb OnlyLF
D01USidewalks 6" thick, unreinforced, 5' wideLF
D01VADA Entrances/Exits, Constructed in Existing Sidewalks, including demolition and disposalEA
D01WCorner-Wide ADA Entrances/Exits, Constructed in Existing Sidewalks, including demolition and disposalEA
D01XADA Entrances/Exits, with new Sidewalk ConstructionEA
D01YCorner-Wide ADA Entrances/Exits, with new Sidewalk ConstructionEA
D01ZHandicap Ramp 1:12 Maximum, 5' wide, with handrail both sidesLF
D020PCC Crack Seal, Rout and Seal Includes all preparation and pressure-applied epoxy sealantLF
D021Spall Repair, PCC PavementSF
Culverts
D022Culvert, 30'' Remove OnlyLF
D023Culvert, 36'' Remove OnlyLF
D024Culvert, 30'' CMP Install Only including end treatmentLF
D025Culvert, 36'' CMP Install Only including end treatmentLF
D026Culvert, 24'' RCP Install Only including end treatmentLF
D027Culvert, 30'' RCP Install Only including end treatmentLF
D028Culvert, 36'' RCP Install Only including end treatmentLF
Handling of Government Furnished Material
D029Material TruckingTON/MI
D02AOn-Base Bulk Material Loading & UnloadingCY
D02BPlacement of government furnished base 6"SY
D02CEach added inch of government furnished base 1"-5"SY
D02DPlacement of government furnished Sub-base 6"SY
D02EEach added inch of goverment furnished Sub-baseSY
Professional and Speciality Services
D02FExploratory Drilling per hole, in earth or AC, each footEA
D02GExploratory Drilling, per hole, in rock or through PCC, each 6'' deepEA
D02HDrive Sample, Testing, and a ReportEA
D02JSoil Sampling, Testing, and a ReportEA
D02K2-Man Survey Team, In-Field Marking and Report (These items are for additional surveying, as required, above and beyond a standard paving project. Surveying incidental to a standard paving project is to be included in the line items associated with the standard paving project.)HR
D02LPot-holing for utilities (These items are for additional pot-holing, as required, above and beyond a standard paving project. Pot-holing incidental to a standard paving project is to be included in the line items associated with the standard paving project.)HR
D02MUnder-Roadway Tunneling for Utility Placement, up to 12" DiameterLF
Material Handling
D02NMaintenance and Reconstruction of SHOULDERS using existing on-site materials onlyLF
D02PMaintenance and reconstruction of ditches using existing, on-site materials onlyLF
D02QCommon ExcavationCY
D02RRock ExcavationCY
D02SExcavation of Unsuitable MaterialsCY
D02TOff-Base Material Disposal (all construction debris; not HAZMAT)CY
D02USelect Fill Material (includes Material and Installation)CY
D02VRaise or Lower Utility CoversEA
Gates, Walls, and Fencing
D02W8' Chain Link FenceLF
D02X3 Fencing Wire outriggersLF
D02Y8' Pedestrian GateLF
D02Z8' Rolling Vehicle GateLF
D0308' Vehicle Swing GateLF
D0318' Heavy-Duty Vehicle Swing GateLF
D032CMU wall, 2' High, split-face blockLF
D033Tortoise Fence, Erection and Removal per plan provided by EMLF
D034Construction of Protective Berms 95% compacted cohesive soil, 8" lifts, graded to smooth finishCY
D035K-RAILS, for use during construction, installation and removalLF
D036Reduced Height airfield barriers, for use during construction, installation and removalLF
Lights and Signage
D037New Installation of Regulatory and Warning Signs, including single postEA
D038Directional Signs, sign-face manufacture and installation on existing posts. Type III or Higher micro prismatic reflective sign panels. ASTM D4956-13 and AASHTO M 268-13.SF
D039Remove and Replace Standard Signs on existing posts. Type III or Higher micro prismatic reflective sign panels. ASTM D4956-13 and AASHTO M 268-13.EA
D03ASteel Breakaway Sign posts, 2" square, frangibly mounted up to 10' above grade. Anodized brown iaw the Edwards Base Design Standards. ASTM A653/A653M, ASTM A1011/A1011M, ASTM A123/A123M.EA
D03BTreated Wooden 8"x8" Sign Posts, up to 20' above grade Painted brown iaw the Edwards Base Design Standards. ASTM D4444, AWPA U1, AWPA.EA
D03CLighting or Utility Pole, breakaway, up to 40' above grade (To Include Alumin. Pole, One Arm Bracket, Up To 6' Deep Conc Base, Wire, and Conduit)EA
D03DSingle LED LuminaireEA
D03EDouble LED LuminaireEA
Joint Repair & Rubber Removal
D03FSilicone Joint RepairLF
D03GJet Fuel Resistant Joint Repair (DLA SS-S-200)LF
D03HCompression Joint SealLF
D03JAirfield Rubber Removal - WATERSF
Demolition
D03KDemo Curb and GutterLF
D03LDemo AsphaltCY
D03MDemo ConcreteCY
Guardrails and Barriers
D03NGuardrailsLF
D03PTL3 Energy Absorbing Barrier EndsEA
D03QTL2 Energy Absorbing Barrier EndsEA
D03RNon-Energy Absorbing Gating EndsEA
D03SEnergy Absorbing Barrels, Installed and FilledEA
D03TTemporary, Changeable Message Signage for Traffic ControlDAY
FOD Control
D03UManual FOD ControlHR
D03VMechanical FOD ControlHR
Non-Prepriced Items
D03WNon-Priced Item (To Be Negotiated Per Task Order)EA

&"Arial,Regular"&8FOR OFFICIAL USE ONLY Source Selection Sensitive Information See FAR 2.101 and 3.104

&"Arial,Regular"&8FA9301-16-R-0011 PAVING ID/IQ SOLICITATION

ATTACHMENT 7 (L-1)

ELIN PRICING TEMPLATE (YEAR 4) (REVISED 11 MAY 2017) &"Arial,Regular"&8FOR OFFICIAL USE ONLY

Year 5

FA9301-16-R-0011 PAVING ID/IQ SOLITICATION
EXHIBIT LINE ITEM NUMBER (ELIN) PRICING TEMPLATE
YEAR 5
Offeror Name:
ELINDESCRIPTIONUNIT OF MEASUREPROPOSED PRICE
Sub-Base Course
E0016'' of Sub-baseSY
E002Each added inch of Sub-baseSY
Subgrade Prep
E0036'' of Subgrade preparationSY
E004Each added inch of Subgrade preparationSY
Base Course
E0056'' of BaseSY
E006Each added inch of BaseSY
ACC Pavement
E007Each 3'' AC (64/28 Polymer Modified Mix)SY
E008Airfield Roadways, Each 3'' AC (64/28 Polymer Modified Mix, no RAP)SY
E009Airfield Shoulders, Each 3'' AC (64/28 Polymer Modified Mix, no RAP)SY
E00AEach Added Inch (64/28 Polymer Modified Mix)SY
E00BAirfield Roadways, Each Added Inch (64/28 Polymer Modified Mix, no RAP)SY
E00CAirfield Shoulders, Each Added Inch (64/28 Polymer Modified Mix, no RAP)SY
E00DAirfield, Each 3'' AC (64/28 Polymer Modified Mix, no RAP)SY
E00EAirfield, Each Added Inch (64/28 Polymer Modified Mix, no RAP)SY
Doweling and Saw Cutting
E00FDowelingEA
E00GSaw Cutting (New Concrete Only)LF
ACC Milling
E00HMill ACC, first inchSY
E00JMilling, each added inchSY
ACC Pulverizing
E00KPulverize ACC and incorporate on-site into base course, up to 6 inches of ACCSY
E00LPulverize ACC and incorporate on-site into base course, each additional inchSY
E00MPulverize ACC and dispose off-baseSY
E00NPulverize ACC and dispose off-base, each additional inchSY
Base and Sub-Base Reinforcement Measures
E00PCement Treated Soil Treatment @ 6% portland cement, top 8" inchesSY
Bituminous Surface Treatment
E00QSingle Coat TreatmentSY
E00RDouble Coat TreatmentSY
ACC Spray Applications
E00STack CoatSY
E00TFog SealsSY
E00UPrime CoatSY
E00VGSB-88 RejuvenatorSY
ACC Crack Seal
E00WACC Crack Seal, Wide Cracks (1'' to 4'')LF
E00XACC Crack Seal, Medium Cracks (1/2" to 1'')LF
E00YACC Crack Seal, Narrow Cracks (1/16" to 1/2'')LF
Slurry Seal
E00ZSingle Application, with Tack CoatSY
E010Single Application, without Tack CoatSY
ACC Patching
E011ACC Patch < 100SYSY
E012ACC Patch > 100SYSY
Roadway and Airfield Markings
E013Roadway Striping, with A/F Type 1 BeadsLF
E014Roadway Striping, with A/F Type 4 BeadsLF
E015Roadway MARKING REFLECTIVE with A/F Type 1 BeadsSF
E016Roadway MARKING REFLECTIVE with A/F Type 4 BeadsSF
E017Roadway Marking, Thermoplastic MaterialSF
E018Airfield Striping, 30" Line total - on Full-Width Black Background, with A/F Type 1 BeadsLF
E019Airfield Striping, 30" Line total - on Full-Width Black Background, with A/F Type 3 BeadsLF
E01AAirfield Markings, with A/F Type 1 BeadsSF
E01BAirfield Markings, with A/F Type 3 BeadsSF
E01CAirfield, Thermoplastic Material Airfield RatedSF
E01DNon-Lead-Based Paint RemovalSF
E01ETemporary Construction-use ReflectorsEA
E01FPermanent, Type D Two-Way Reflective MarkersEA
E01GPermanent, Type G One-Way ReflectorsEA
E01HRumble Strips, rubberized material purchased and installed post-constructionEA
E01JRumble Strips, created in ACC at constructionLF
Concrete Work
E01KReinforced PCC Airfield, 650 psi Flexural Strength (ASR Free Aggregate)CY
E01LUnreinforced PCC Airfield, 650 psi Flexural Strength (ASR Free Aggregate)CY
E01MPCC Roadway, Roadway UseCY
E01NReinforced Concrete Pad, Formed and Cast in-placeCY
E01PReinforced PCC Headwall, Formed and Cast-in-placeCY
E01QPCC Valley GuttersCF
E01RPCC SpandrelsCF
E01S6" Curb with 18" GutterLF
E01T6" Curb, Curb OnlyLF
E01USidewalks 6" thick, unreinforced, 5' wideLF
E01VADA Entrances/Exits, Constructed in Existing Sidewalks, including demolition and disposalEA
E01WCorner-Wide ADA Entrances/Exits, Constructed in Existing Sidewalks, including demolition and disposalEA
E01XADA Entrances/Exits, with new Sidewalk ConstructionEA
E01YCorner-Wide ADA Entrances/Exits, with new Sidewalk ConstructionEA
E01ZHandicap Ramp 1:12 Maximum, 5' wide, with handrail both sidesLF
E020PCC Crack Seal, Rout and Seal Includes all preparation and pressure-applied epoxy sealantLF
E021Spall Repair, PCC PavementSF
Culverts
E022Culvert, 30'' Remove OnlyLF
E023Culvert, 36'' Remove OnlyLF
E024Culvert, 30'' CMP Install Only including end treatmentLF
E025Culvert, 36'' CMP Install Only including end treatmentLF
E026Culvert, 24'' RCP Install Only including end treatmentLF
E027Culvert, 30'' RCP Install Only including end treatmentLF
E028Culvert, 36'' RCP Install Only including end treatmentLF
Handling of Government Furnished Material
E029Material TruckingTON/MI
E02AOn-Base Bulk Material Loading & UnloadingCY
E02BPlacement of government furnished base 6"SY
E02CEach added inch of government furnished base 1"-5"SY
E02DPlacement of government furnished Sub-base 6"SY
E02EEach added inch of goverment furnished Sub-baseSY
Professional and Speciality Services
E02FExploratory Drilling per hole, in earth or AC, each footEA
E02GExploratory Drilling, per hole, in rock or through PCC, each 6'' deepEA
E02HDrive Sample, Testing, and a ReportEA
E02JSoil Sampling, Testing, and a ReportEA
E02K2-Man Survey Team, In-Field Marking and Report (These items are for additional surveying, as required, above and beyond a standard paving project. Surveying incidental to a standard paving project is to be included in the line items associated with the standard paving project.)HR
E02LPot-holing for utilities (These items are for additional pot-holing, as required, above and beyond a standard paving project. Pot-holing incidental to a standard paving project is to be included in the line items associated with the standard paving project.)HR
E02MUnder-Roadway Tunneling for Utility Placement, up to 12" DiameterLF
Material Handling
E02NMaintenance and Reconstruction of SHOULDERS using existing on-site materials onlyLF
E02PMaintenance and reconstruction of ditches using existing, on-site materials onlyLF
E02QCommon ExcavationCY
E02RRock ExcavationCY
E02SExcavation of Unsuitable MaterialsCY
E02TOff-Base Material Disposal (all construction debris; not HAZMAT)CY
E02USelect Fill Material (includes Material and Installation)CY
E02VRaise or Lower Utility CoversEA
Gates, Walls, and Fencing
E02W8' Chain Link FenceLF
E02X3 Fencing Wire outriggersLF
E02Y8' Pedestrian GateLF
E02Z8' Rolling Vehicle GateLF
E0308' Vehicle Swing GateLF
E0318' Heavy-Duty Vehicle Swing GateLF
E032CMU wall, 2' High, split-face blockLF
E033Tortoise Fence, Erection and Removal per plan provided by EMLF
E034Construction of Protective Berms 95% compacted cohesive soil, 8" lifts, graded to smooth finishCY
E035K-RAILS, for use during construction, installation and removalLF
E036Reduced Height airfield barriers, for use during construction, installation and removalLF
Lights and Signage
E037New Installation of Regulatory and Warning Signs, including single postEA
E038Directional Signs, sign-face manufacture and installation on existing posts. Type III or Higher micro prismatic reflective sign panels. ASTM D4956-13 and AASHTO M 268-13.SF
E039Remove and Replace Standard Signs on existing posts. Type III or Higher micro prismatic reflective sign panels. ASTM D4956-13 and AASHTO M 268-13.EA
E03ASteel Breakaway Sign posts, 2" square, frangibly mounted up to 10' above grade. Anodized brown iaw the Edwards Base Design Standards. ASTM A653/A653M, ASTM A1011/A1011M, ASTM A123/A123M.EA
E03BTreated Wooden 8"x8" Sign Posts, up to 20' above grade Painted brown iaw the Edwards Base Design Standards. ASTM D4444, AWPA U1, AWPA.EA
E03CLighting or Utility Pole, breakaway, up to 40' above grade (To Include Alumin. Pole, One Arm Bracket, Up To 6' Deep Conc Base, Wire, and Conduit)EA
E03DSingle LED LuminaireEA
E03EDouble LED LuminaireEA
Joint Repair & Rubber Removal
E03FSilicone Joint RepairLF
E03GJet Fuel Resistant Joint Repair (DLA SS-S-200)LF
E03HCompression Joint SealLF
E03JAirfield Rubber Removal - WATERSF
Demolition
E03KDemo Curb and GutterLF
E03LDemo AsphaltCY
E03MDemo ConcreteCY
Guardrails and Barriers
E03NGuardrailsLF
E03PTL3 Energy Absorbing Barrier EndsEA
E03QTL2 Energy Absorbing Barrier EndsEA
E03RNon-Energy Absorbing Gating EndsEA
E03SEnergy Absorbing Barrels, Installed and FilledEA
E03TTemporary, Changeable Message Signage for Traffic ControlDAY
FOD Control
E03UManual FOD ControlHR
E03VMechanical FOD ControlHR
Non-Prepriced Items
E03WNon-Priced Item (To Be Negotiated Per Task Order)EA

&"Arial,Regular"&8FOR OFFICIAL USE ONLY Source Selection Sensitive Information See FAR 2.101 and 3.104

&"Arial,Regular"&8FA9301-16-R-0011 PAVING ID/IQ SOLICITATION

ATTACHMENT 7 (L-1)

ELIN PRICING TEMPLATE (YEAR 5) (REVISED 11 MAY 2017) &"Arial,Regular"&8FOR OFFICIAL USE ONLY

File details come from the government source that posted it. Updated .