Atch_7_(L-1)_ELIN_Pricing_Template.xlsx
XLSX spreadsheet 59 KB Posted
- Attached to
- Paving Indefinite Delivery/Indefinite Quantity (ID/IQ) Contract Federal contract opportunity
- Solicitation number
- FA9301-16-R-0011
About this file
7. (L-1) ELIN Pricing Template
View the file
Other files for this federal contract opportunity
Show all 48
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Year 1
| FA9301-16-R-0011 PAVING ID/IQ SOLITICATION | |||
| EXHIBIT LINE ITEM NUMBER (ELIN) PRICING TEMPLATE | |||
| YEAR 1 | |||
| Offeror Name: | |||
| ELIN | DESCRIPTION | UNIT OF MEASURE | PROPOSED PRICE |
| Sub-Base Course | |||
| A001 | Each 6'' of Sub-base preparation | SY | |
| A002 | Each added inch of Sub-base preparation | SY | |
| Base Course | |||
| A003 | 6'' Base | SY | |
| A004 | Added Base Inch 1"-5" | SY | |
| ACC Pavement | |||
| A005 | Each 3'' AC (64/28 Polymer Modified Mix) | SY | |
| A006 | Airfield Roadways, Each 3'' AC (64/28 Polymer Modified Mix, no RAP) | SY | |
| A007 | Airfield Shoulders, Each 3'' AC (64/28 Polymer Modified Mix, no RAP) | SY | |
| A008 | Each Added Inch (64/28 Polymer Modified Mix) | SY | |
| A009 | Airfield Roadways, Each Added Inch (64/28 Polymer Modified Mix, no RAP) | SY | |
| A00A | Airfield Shoulders, Each Added Inch (64/28 Polymer Modified Mix, no RAP) | SY | |
| A00B | Airfield - Load Bearing, Each 3'' AC (64/28 Polymer Modified Mix, no RAP) | SY | |
| A00C | Airfield - Load-Bearing Each Added Inch (64/28 Polymer Modified Mix, no RAP) | SY | |
| ACC Milling | |||
| A00D | Mill ACC, first inch | SY | |
| A00E | Milling, each added inch | SY | |
| ACC Pulverization | |||
| A00F | Pulverize ACC and incorporate on-site into base course, each 3" | SY | |
| A00G | Pulverize ACC and dispose off-base | SY | |
| Base and Sub-Base Reinforcement Measures | |||
| A00H | Cement Treated Soil Treatment @ 6% portland cement, top 8" inches | SY | |
| Bituminous Surface Treatment | |||
| A00J | Single Coat Treatment | SY | |
| A00K | Double Coat Treatment | SY | |
| ACC Spray Applications | |||
| A00L | Tack Coat | SY | |
| A00M | Fog Seals | SY | |
| A00N | Prime Coat | SY | |
| A00P | GSB-88 Rejuvenator | SY | |
| ACC Crack Seal | |||
| A00Q | ACC Crack Seal, Wide Cracks (1'' to 4'') | LF | |
| A00R | ACC Crack Seal, Medium Cracks (1/2" to 1'') | LF | |
| A00S | ACC Crack Seal, Narrow Cracks (1/16" to 1/2'') | LF | |
| Slurry Seal | |||
| A00T | Single Application, with Tack Coat | SY | |
| A00U | Single Application, without Tack Coat | SY | |
| ACC Patching | |||
| A00V | ACC Patch < 100SY | SY | |
| A00W | ACC Patch >100SY | SY | |
| Roadway and Airfield Markings | |||
| A00X | Roadway Striping, 4'' Line, with A/F Type 1 Beads | SF | |
| A00Y | Roadway Striping, 4'' Line, with A/F Type 4 Beads | SF | |
| A00Z | Roadway MARKING REFLECTIVE with A/F Type 1 Beads | SF | |
| A010 | Roadway MARKING REFLECTIVE with A/F Type 4 Beads | SF | |
| A011 | Roadway Marking, Thermoplastic Material | SF | |
| A012 | Airfield Striping, 30" Line total - on Full-Width Black Background, with A/F Type 1 Beads | LF | |
| A013 | Airfield Striping, 30" Line total - on Full-Width Black Background, with A/F Type 3 Beads | LF | |
| A014 | Airfield Markings, with A/F Type 1 Beads | SF | |
| A015 | Airfield Markings, with A/F Type 3 Beads | SF | |
| A016 | Airfield, Thermoplastic Material Airfield Rated | SF | |
| A017 | Non-Lead-Based Paint Removal | SF | |
| A018 | Temporary Construction-use Reflectors | EA | |
| A019 | Permanent, Type D Two-Way Reflective Markers | EA | |
| A01A | Permanent, Type G One-Way Reflectors | EA | |
| A01B | Rumble Strips, rubberized material purchased and installed post-construction | EA | |
| A01C | Rumble Strips, created in ACC at construction | LF | |
| Concrete Work | |||
| A01D | Reinforced PCC Airfield, 650 psi Flexural Strength (ASR Free Aggregate) | CY | |
| A01E | Unreinforced PCC Airfield, 650 psi Flexural Strength (ASR Free Aggregate) | CY | |
| A01F | PCC Roadway, Roadway Use, Slipform | CY | |
| A01G | Reinforced Concrete Pad, Formed and Cast in-place | CY | |
| A01H | Reinforced PCC Headwall, Formed and Cast-in-place | CY | |
| A01J | PCC Valley Gutters | CF | |
| A01K | PCC Spandrels | CF | |
| A01L | 6" Curb with 18" Gutter | LF | |
| A01M | 6" Curb, Curb Only | LF | |
| A01N | Sidewalks 6" thick, unreinforced, 5' wide | LF | |
| A01P | ADA Entrances/Exits, Constructed in Existing Sidewalks, including demolition and disposal | EA | |
| A01Q | Corner-Wide ADA Entrances/Exits, Constructed in Existing Sidewalks, including demolition and disposal | EA | |
| A01R | ADA Entrances/Exits, with new Sidewalk Construction | EA | |
| A01S | Corner-Wide ADA Entrances/Exits, with new Sidewalk Construction | EA | |
| A01T | Handicap Ramp 1:12 Maximum, 5' wide, with handrail both sides | LF | |
| A01U | PCC Crack Seal, Rout and Seal Includes all preparation and pressure-applied epoxy sealant | LF | |
| A01V | Spall Repair, PCC Pavement | SF | |
| Culverts | |||
| A01W | Culvert, 30'' Remove Only | LF | |
| A01X | Culvert, 36'' Remove Only | LF | |
| A01Y | Culvert, 30'' CMP Install Only including end treatment | LF | |
| A01Z | Culvert, 36'' CMP Install Only including end treatment | LF | |
| A020 | Culvert, 24'' RCP Install Only including end treatment | LF | |
| A021 | Culvert, 30'' RCP Install Only including end treatment | LF | |
| A022 | Culvert, 36'' RCP Install Only including end treatment | LF | |
| Handling of Government Furnished Material | |||
| A023 | Material Trucking | TON/MI | |
| A024 | On-Base Bulk Material Loading & Unloading | CY | |
| A025 | Placement of government furnished base 6" | SY | |
| A026 | Each added inch of government furnished base 1"-5" | SY | |
| A027 | Placement of government furnished Sub-base 6" | SY | |
| A028 | Each added inch of goverment furnished Sub-base | SY | |
| Professional and Speciality Services | |||
| A029 | Exploratory Drilling per hole, in earth or AC, each foot | EA | |
| A02A | Exploratory Drilling, per hole, in rock or through PCC, each 6'' deep | EA | |
| A02B | Drive Sample, Testing, and a Report | EA | |
| A02C | Soil Sampling, Testing, and a Report | EA | |
| A02D | 2-Man Survey Team, In-Field Marking and Report (These items are for additional surveying, as required, above and beyond a standard paving project. Surveying incidental to a standard paving project is to be included in the line items associated with the standard paving project.) | HR | |
| A02E | Pot-holing for utilities (These items are for additional pot-holing, as required, above and beyond a standard paving project. Pot-holing incidental to a standard paving project is to be included in the line items associated with the standard paving project.) | HR | |
| A02F | Under-Roadway Tunneling for Utility Placement, up to 12" Diameter | LF | |
| Material Handling | |||
| A02G | Maintenance and Reconstruction of SHOULDERS using existing on-site materials only | LF | |
| A02H | Maintenance and reconstruction of ditches using existing, on-site materials only | LF | |
| A02J | Common Excavation | CY | |
| A02K | Rock Excavation | CY | |
| A02L | Excavation of Unsuitable Materials | CY | |
| A02M | Off-Base Material Disposal | CY | |
| A02N | Select Fill Material | CY | |
| A02P | Raise or Lower Utility Covers | EA | |
| Gates, Walls, and Fencing | |||
| A02Q | 8' Chain Link Fence | LF | |
| A02R | 3 Fencing Wire outriggers | LF | |
| A02S | 8' Pedestrian Gate | LF | |
| A02T | 8' Rolling Vehicle Gate | LF | |
| A02U | 8' Vehicle Swing Gate | LF | |
| A02V | 8' Heavy-Duty Vehicle Swing Gate | LF | |
| A02W | CMU wall, 2' High, split-face block | LF | |
| A02X | Tortoise Fence, Erection and Removal per plan provided by EM | LF | |
| A02Y | Construction of Protective Berms 95% compacted cohesive soil, 8" lifts, graded to smooth finish | CY | |
| A02Z | K-RAILS, for use during construction, installation and removal | LF | |
| A030 | Reduced Height airfield barriers, for use during construction, installation and removal | LF | |
| Lights and Signage | |||
| A031 | New Installation of Regulatory and Warning Signs, including single post | EA | |
| A032 | Directional Signs, sign-face manufacture and installation on existing posts. Type III or Higher micro prismatic reflective sign panels. ASTM D4956-13 and AASHTO M 268-13. | SF | |
| A033 | Remove and Replace Standard Signs on existing posts. Type III or Higher micro prismatic reflective sign panels. ASTM D4956-13 and AASHTO M 268-13. | EA | |
| A034 | Steel Breakaway Sign posts, 2" square, frangibly mounted up to 10' above grade. Anodized brown iaw the Edwards Base Design Standards. ASTM A653/A653M, ASTM A1011/A1011M, ASTM A123/A123M. | EA | |
| A035 | Treated Wooden 8"x8" Sign Posts, up to 20' above grade Painted brown iaw the Edwards Base Design Standards. ASTM D4444, AWPA U1, AWPA. | EA | |
| A036 | Lighting or Utility Pole, breakaway, up to 40' above grade (To Include Alumin. Pole, One Arm Bracket, Up To 6' Deep Conc Base, Wire, and Conduit) | EA | |
| A037 | Single LED Luminaire | EA | |
| A038 | Double LED Luminaire | EA | |
| Joint Repair & Rubber Removal | |||
| A039 | Silicone Joint Repair | LF | |
| A03A | Jet Fuel Resistant Joint Repair (DLA SS-S-200) | LF | |
| A03B | Compression Joint Seal | LF | |
| A03C | Airfield Rubber Removal - WATER | SF | |
| Demolition and Disposal | |||
| A03D | Demo Curb and Gutter | LF | |
| A03E | Demo Asphalt | CY | |
| A03F | Demo Concrete | CY | |
| Guardrails and Barriers | |||
| A03G | Guardrails | LF | |
| A03H | TL3 Energy Absorbing Barrier Ends | EA | |
| A03J | TL2 Energy Absorbing Barrier Ends | EA | |
| A03K | Non-Energy Absorbing Gating Ends | EA | |
| A03L | Energy Absorbing Barrels, Installed and Filled | EA | |
| A03M | Temporary, Changeable Message Signage for Traffic Control | DAY | |
| FOD Control | |||
| A03N | Manual FOD Control | HR | |
| A03P | Mechanical FOD Control | HR | |
| Non-Prepriced Items | |||
| A03Q | Non-Priced Item (To Be Negotiated Per Task Order) | EA | |
| TOTAL |
&"Arial,Regular"&8FOR OFFICIAL USE ONLY Source Selection Sensitive Information See FAR 2.101 and 3.104
&"Arial,Regular"&8FA9301-16-R-0011 PAVING ID/IQ SOLICITATION
ATTACHMENT 7 (L-1)
ELIN PRICING TEMPLATE (YEAR 1) &8FOR OFFICIAL USE ONLY
See FAR 2.101 and 3.104
Year 2
| FA9301-16-R-0011 PAVING ID/IQ SOLITICATION | |||
| EXHIBIT LINE ITEM NUMBER (ELIN) PRICING TEMPLATE | |||
| YEAR 2 | |||
| Offeror Name: | |||
| ELIN | DESCRIPTION | UNIT OF MEASURE | PROPOSED PRICE |
| Sub-Base Course | |||
| B001 | Each 6'' of Sub-base preparation | SY | |
| B002 | Each added inch of Sub-base preparation | SY | |
| Base Course | |||
| B003 | 6'' Base | SY | |
| B004 | Added Base Inch 1"-5" | SY | |
| ACC Pavement | |||
| B005 | Each 3'' AC (64/28 Polymer Modified Mix) | SY | |
| B006 | Airfield Roadways, Each 3'' AC (64/28 Polymer Modified Mix, no RAP) | SY | |
| B007 | Airfield Shoulders, Each 3'' AC (64/28 Polymer Modified Mix, no RAP) | SY | |
| B008 | Each Added Inch (64/28 Polymer Modified Mix) | SY | |
| B009 | Airfield Roadways, Each Added Inch (64/28 Polymer Modified Mix, no RAP) | SY | |
| B00A | Airfield Shoulders, Each Added Inch (64/28 Polymer Modified Mix, no RAP) | SY | |
| B00B | Airfield - Load Bearing, Each 3'' AC (64/28 Polymer Modified Mix, no RAP) | SY | |
| B00C | Airfield - Load-Bearing Each Added Inch (64/28 Polymer Modified Mix, no RAP) | SY | |
| ACC Milling | |||
| B00D | Mill ACC, first inch | SY | |
| B00E | Milling, each added inch | SY | |
| ACC Pulverization | |||
| B00F | Pulverize ACC and incorporate on-site into base course, each 3" | SY | |
| B00G | Pulverize ACC and dispose off-base | SY | |
| Base and Sub-Base Reinforcement Measures | |||
| B00H | Cement Treated Soil Treatment @ 6% portland cement, top 8" inches | SY | |
| Bituminous Surface Treatment | |||
| B00J | Single Coat Treatment | SY | |
| B00K | Double Coat Treatment | SY | |
| ACC Spray Applications | |||
| B00L | Tack Coat | SY | |
| B00M | Fog Seals | SY | |
| B00N | Prime Coat | SY | |
| B00P | GSB-88 Rejuvenator | SY | |
| ACC Crack Seal | |||
| B00Q | ACC Crack Seal, Wide Cracks (1'' to 4'') | LF | |
| B00R | ACC Crack Seal, Medium Cracks (1/2" to 1'') | LF | |
| B00S | ACC Crack Seal, Narrow Cracks (1/16" to 1/2'') | LF | |
| Slurry Seal | |||
| B00T | Single Application, with Tack Coat | SY | |
| B00U | Single Application, without Tack Coat | SY | |
| ACC Patching | |||
| B00V | ACC Patch < 100SY | SY | |
| B00W | ACC Patch >100SY | SY | |
| Roadway and Airfield Markings | |||
| B00X | Roadway Striping, 4'' Line, with A/F Type 1 Beads | SF | |
| B00Y | Roadway Striping, 4'' Line, with A/F Type 4 Beads | SF | |
| B00Z | Roadway MARKING REFLECTIVE with A/F Type 1 Beads | SF | |
| B010 | Roadway MARKING REFLECTIVE with A/F Type 4 Beads | SF | |
| B011 | Roadway Marking, Thermoplastic Material | SF | |
| B012 | Airfield Striping, 30" Line total - on Full-Width Black Background, with A/F Type 1 Beads | LF | |
| B013 | Airfield Striping, 30" Line total - on Full-Width Black Background, with A/F Type 3 Beads | LF | |
| B014 | Airfield Markings, with A/F Type 1 Beads | SF | |
| B015 | Airfield Markings, with A/F Type 3 Beads | SF | |
| B016 | Airfield, Thermoplastic Material Airfield Rated | SF | |
| B017 | Non-Lead-Based Paint Removal | SF | |
| B018 | Temporary Construction-use Reflectors | EA | |
| B019 | Permanent, Type D Two-Way Reflective Markers | EA | |
| B01A | Permanent, Type G One-Way Reflectors | EA | |
| B01B | Rumble Strips, rubberized material purchased and installed post-construction | EA | |
| B01C | Rumble Strips, created in ACC at construction | LF | |
| Concrete Work | |||
| B01D | Reinforced PCC Airfield, 650 psi Flexural Strength (ASR Free Aggregate) | CY | |
| B01E | Unreinforced PCC Airfield, 650 psi Flexural Strength (ASR Free Aggregate) | CY | |
| B01F | PCC Roadway, Roadway Use, Slipform | CY | |
| B01G | Reinforced Concrete Pad, Formed and Cast in-place | CY | |
| B01H | Reinforced PCC Headwall, Formed and Cast-in-place | CY | |
| B01J | PCC Valley Gutters | CF | |
| B01K | PCC Spandrels | CF | |
| B01L | 6" Curb with 18" Gutter | LF | |
| B01M | 6" Curb, Curb Only | LF | |
| B01N | Sidewalks 6" thick, unreinforced, 5' wide | LF | |
| B01P | ADA Entrances/Exits, Constructed in Existing Sidewalks, including demolition and disposal | EA | |
| B01Q | Corner-Wide ADA Entrances/Exits, Constructed in Existing Sidewalks, including demolition and disposal | EA | |
| B01R | ADA Entrances/Exits, with new Sidewalk Construction | EA | |
| B01S | Corner-Wide ADA Entrances/Exits, with new Sidewalk Construction | EA | |
| B01T | Handicap Ramp 1:12 Maximum, 5' wide, with handrail both sides | LF | |
| B01U | PCC Crack Seal, Rout and Seal Includes all preparation and pressure-applied epoxy sealant | LF | |
| B01V | Spall Repair, PCC Pavement | SF | |
| Culverts | |||
| B01W | Culvert, 30'' Remove Only | LF | |
| B01X | Culvert, 36'' Remove Only | LF | |
| B01Y | Culvert, 30'' CMP Install Only including end treatment | LF | |
| B01Z | Culvert, 36'' CMP Install Only including end treatment | LF | |
| B020 | Culvert, 24'' RCP Install Only including end treatment | LF | |
| B021 | Culvert, 30'' RCP Install Only including end treatment | LF | |
| B022 | Culvert, 36'' RCP Install Only including end treatment | LF | |
| Handling of Government Furnished Material | |||
| B023 | Material Trucking | TON/MI | |
| B024 | On-Base Bulk Material Loading & Unloading | CY | |
| B025 | Placement of government furnished base 6" | SY | |
| B026 | Each added inch of government furnished base 1"-5" | SY | |
| B027 | Placement of government furnished Sub-base 6" | SY | |
| B028 | Each added inch of goverment furnished Sub-base | SY | |
| Professional and Speciality Services | |||
| B029 | Exploratory Drilling per hole, in earth or AC, each foot | EA | |
| B02A | Exploratory Drilling, per hole, in rock or through PCC, each 6'' deep | EA | |
| B02B | Drive Sample, Testing, and a Report | EA | |
| B02C | Soil Sampling, Testing, and a Report | EA | |
| B02D | 2-Man Survey Team, In-Field Marking and Report (These items are for additional surveying, as required, above and beyond a standard paving project. Surveying incidental to a standard paving project is to be included in the line items associated with the standard paving project.) | HR | |
| B02E | Pot-holing for utilities (These items are for additional pot-holing, as required, above and beyond a standard paving project. Pot-holing incidental to a standard paving project is to be included in the line items associated with the standard paving project.) | HR | |
| B02F | Under-Roadway Tunneling for Utility Placement, up to 12" Diameter | LF | |
| Material Handling | |||
| B02G | Maintenance and Reconstruction of SHOULDERS using existing on-site materials only | LF | |
| B02H | Maintenance and reconstruction of ditches using existing, on-site materials only | LF | |
| B02J | Common Excavation | CY | |
| B02K | Rock Excavation | CY | |
| B02L | Excavation of Unsuitable Materials | CY | |
| B02M | Off-Base Material Disposal | CY | |
| B02N | Select Fill Material | CY | |
| B02P | Raise or Lower Utility Covers | EA | |
| Gates, Walls, and Fencing | |||
| B02Q | 8' Chain Link Fence | LF | |
| B02R | 3 Fencing Wire outriggers | LF | |
| B02S | 8' Pedestrian Gate | LF | |
| B02T | 8' Rolling Vehicle Gate | LF | |
| B02U | 8' Vehicle Swing Gate | LF | |
| B02V | 8' Heavy-Duty Vehicle Swing Gate | LF | |
| B02W | CMU wall, 2' High, split-face block | LF | |
| B02X | Tortoise Fence, Erection and Removal per plan provided by EM | LF | |
| B02Y | Construction of Protective Berms 95% compacted cohesive soil, 8" lifts, graded to smooth finish | CY | |
| B02Z | K-RAILS, for use during construction, installation and removal | LF | |
| B030 | Reduced Height airfield barriers, for use during construction, installation and removal | LF | |
| Lights and Signage | |||
| B031 | New Installation of Regulatory and Warning Signs, including single post | EA | |
| B032 | Directional Signs, sign-face manufacture and installation on existing posts. Type III or Higher micro prismatic reflective sign panels. ASTM D4956-13 and AASHTO M 268-13. | SF | |
| B033 | Remove and Replace Standard Signs on existing posts. Type III or Higher micro prismatic reflective sign panels. ASTM D4956-13 and AASHTO M 268-13. | EA | |
| B034 | Steel Breakaway Sign posts, 2" square, frangibly mounted up to 10' above grade. Anodized brown iaw the Edwards Base Design Standards. ASTM A653/A653M, ASTM A1011/A1011M, ASTM A123/A123M. | EA | |
| B035 | Treated Wooden 8"x8" Sign Posts, up to 20' above grade Painted brown iaw the Edwards Base Design Standards. ASTM D4444, AWPA U1, AWPA. | EA | |
| B036 | Lighting or Utility Pole, breakaway, up to 40' above grade (To Include Alumin. Pole, One Arm Bracket, Up To 6' Deep Conc Base, Wire, and Conduit) | EA | |
| B037 | Single LED Luminaire | EA | |
| B038 | Double LED Luminaire | EA | |
| Joint Repair & Rubber Removal | |||
| B039 | Silicone Joint Repair | LF | |
| B03A | Jet Fuel Resistant Joint Repair (DLA SS-S-200) | LF | |
| B03B | Compression Joint Seal | LF | |
| B03C | Airfield Rubber Removal - WATER | SF | |
| Demolition and Disposal | |||
| B03D | Demo Curb and Gutter | LF | |
| B03E | Demo Asphalt | CY | |
| B03F | Demo Concrete | CY | |
| Guardrails and Barriers | |||
| B03G | Guardrails | LF | |
| B03H | TL3 Energy Absorbing Barrier Ends | EA | |
| B03J | TL2 Energy Absorbing Barrier Ends | EA | |
| B03K | Non-Energy Absorbing Gating Ends | EA | |
| B03L | Energy Absorbing Barrels, Installed and Filled | EA | |
| B03M | Temporary, Changeable Message Signage for Traffic Control | DAY | |
| FOD Control | |||
| B03N | Manual FOD Control | HR | |
| B03P | Mechanical FOD Control | HR | |
| Non-Prepriced Items | |||
| B03Q | Non-Priced Item (To Be Negotiated Per Task Order) | EA | |
| TOTAL |
See FAR 2.101 and 3.104
&"Arial,Regular"&8FA9301-16-R-0011 PAVING ID/IQ SOLICITATION
ATTACHMENT 7 (L-1)
ELIN PRICING TEMPLATE (YEAR 2) &"Arial,Regular"&8FOR OFFICIAL USE ONLY
Year 3
| FA9301-16-R-0011 PAVING ID/IQ SOLITICATION | |||
| EXHIBIT LINE ITEM NUMBER (ELIN) PRICING TEMPLATE | |||
| YEAR 3 | |||
| Offeror Name: | |||
| ELIN | DESCRIPTION | UNIT OF MEASURE | PROPOSED PRICE |
| Sub-Base Course | |||
| C001 | Each 6'' of Sub-base preparation | SY | |
| C002 | Each added inch of Sub-base preparation | SY | |
| Base Course | |||
| C003 | 6'' Base | SY | |
| C004 | Added Base Inch 1"-5" | SY | |
| ACC Pavement | |||
| C005 | Each 3'' AC (64/28 Polymer Modified Mix) | SY | |
| C006 | Airfield Roadways, Each 3'' AC (64/28 Polymer Modified Mix, no RAP) | SY | |
| C007 | Airfield Shoulders, Each 3'' AC (64/28 Polymer Modified Mix, no RAP) | SY | |
| C008 | Each Added Inch (64/28 Polymer Modified Mix) | SY | |
| C009 | Airfield Roadways, Each Added Inch (64/28 Polymer Modified Mix, no RAP) | SY | |
| C00A | Airfield Shoulders, Each Added Inch (64/28 Polymer Modified Mix, no RAP) | SY | |
| C00B | Airfield - Load Bearing, Each 3'' AC (64/28 Polymer Modified Mix, no RAP) | SY | |
| C00C | Airfield - Load-Bearing Each Added Inch (64/28 Polymer Modified Mix, no RAP) | SY | |
| ACC Milling | |||
| C00D | Mill ACC, first inch | SY | |
| C00E | Milling, each added inch | SY | |
| ACC Pulverization | |||
| C00F | Pulverize ACC and incorporate on-site into base course, each 3" | SY | |
| C00G | Pulverize ACC and dispose off-base | SY | |
| Base and Sub-Base Reinforcement Measures | |||
| C00H | Cement Treated Soil Treatment @ 6% portland cement, top 8" inches | SY | |
| Bituminous Surface Treatment | |||
| C00J | Single Coat Treatment | SY | |
| C00K | Double Coat Treatment | SY | |
| ACC Spray Applications | |||
| C00L | Tack Coat | SY | |
| C00M | Fog Seals | SY | |
| C00N | Prime Coat | SY | |
| C00P | GSB-88 Rejuvenator | SY | |
| ACC Crack Seal | |||
| C00Q | ACC Crack Seal, Wide Cracks (1'' to 4'') | LF | |
| C00R | ACC Crack Seal, Medium Cracks (1/2" to 1'') | LF | |
| C00S | ACC Crack Seal, Narrow Cracks (1/16" to 1/2'') | LF | |
| Slurry Seal | |||
| C00T | Single Application, with Tack Coat | SY | |
| C00U | Single Application, without Tack Coat | SY | |
| ACC Patching | |||
| C00V | ACC Patch < 100SY | SY | |
| C00W | ACC Patch >100SY | SY | |
| Roadway and Airfield Markings | |||
| C00X | Roadway Striping, 4'' Line, with A/F Type 1 Beads | SF | |
| C00Y | Roadway Striping, 4'' Line, with A/F Type 4 Beads | SF | |
| C00Z | Roadway MARKING REFLECTIVE with A/F Type 1 Beads | SF | |
| C010 | Roadway MARKING REFLECTIVE with A/F Type 4 Beads | SF | |
| C011 | Roadway Marking, Thermoplastic Material | SF | |
| C012 | Airfield Striping, 30" Line total - on Full-Width Black Background, with A/F Type 1 Beads | LF | |
| C013 | Airfield Striping, 30" Line total - on Full-Width Black Background, with A/F Type 3 Beads | LF | |
| C014 | Airfield Markings, with A/F Type 1 Beads | SF | |
| C015 | Airfield Markings, with A/F Type 3 Beads | SF | |
| C016 | Airfield, Thermoplastic Material Airfield Rated | SF | |
| C017 | Non-Lead-Based Paint Removal | SF | |
| C018 | Temporary Construction-use Reflectors | EA | |
| C019 | Permanent, Type D Two-Way Reflective Markers | EA | |
| C01A | Permanent, Type G One-Way Reflectors | EA | |
| C01B | Rumble Strips, rubberized material purchased and installed post-construction | EA | |
| C01C | Rumble Strips, created in ACC at construction | LF | |
| Concrete Work | |||
| C01D | Reinforced PCC Airfield, 650 psi Flexural Strength (ASR Free Aggregate) | CY | |
| C01E | Unreinforced PCC Airfield, 650 psi Flexural Strength (ASR Free Aggregate) | CY | |
| C01F | PCC Roadway, Roadway Use, Slipform | CY | |
| C01G | Reinforced Concrete Pad, Formed and Cast in-place | CY | |
| C01H | Reinforced PCC Headwall, Formed and Cast-in-place | CY | |
| C01J | PCC Valley Gutters | CF | |
| C01K | PCC Spandrels | CF | |
| C01L | 6" Curb with 18" Gutter | LF | |
| C01M | 6" Curb, Curb Only | LF | |
| C01N | Sidewalks 6" thick, unreinforced, 5' wide | LF | |
| C01P | ADA Entrances/Exits, Constructed in Existing Sidewalks, including demolition and disposal | EA | |
| C01Q | Corner-Wide ADA Entrances/Exits, Constructed in Existing Sidewalks, including demolition and disposal | EA | |
| C01R | ADA Entrances/Exits, with new Sidewalk Construction | EA | |
| C01S | Corner-Wide ADA Entrances/Exits, with new Sidewalk Construction | EA | |
| C01T | Handicap Ramp 1:12 Maximum, 5' wide, with handrail both sides | LF | |
| C01U | PCC Crack Seal, Rout and Seal Includes all preparation and pressure-applied epoxy sealant | LF | |
| C01V | Spall Repair, PCC Pavement | SF | |
| Culverts | |||
| C01W | Culvert, 30'' Remove Only | LF | |
| C01X | Culvert, 36'' Remove Only | LF | |
| C01Y | Culvert, 30'' CMP Install Only including end treatment | LF | |
| C01Z | Culvert, 36'' CMP Install Only including end treatment | LF | |
| C020 | Culvert, 24'' RCP Install Only including end treatment | LF | |
| C021 | Culvert, 30'' RCP Install Only including end treatment | LF | |
| C022 | Culvert, 36'' RCP Install Only including end treatment | LF | |
| Handling of Government Furnished Material | |||
| C023 | Material Trucking | TON/MI | |
| C024 | On-Base Bulk Material Loading & Unloading | CY | |
| C025 | Placement of government furnished base 6" | SY | |
| C026 | Each added inch of government furnished base 1"-5" | SY | |
| C027 | Placement of government furnished Sub-base 6" | SY | |
| C028 | Each added inch of goverment furnished Sub-base | SY | |
| Professional and Speciality Services | |||
| C029 | Exploratory Drilling per hole, in earth or AC, each foot | EA | |
| C02A | Exploratory Drilling, per hole, in rock or through PCC, each 6'' deep | EA | |
| C02B | Drive Sample, Testing, and a Report | EA | |
| C02C | Soil Sampling, Testing, and a Report | EA | |
| C02D | 2-Man Survey Team, In-Field Marking and Report (These items are for additional surveying, as required, above and beyond a standard paving project. Surveying incidental to a standard paving project is to be included in the line items associated with the standard paving project.) | HR | |
| C02E | Pot-holing for utilities (These items are for additional pot-holing, as required, above and beyond a standard paving project. Pot-holing incidental to a standard paving project is to be included in the line items associated with the standard paving project.) | HR | |
| C02F | Under-Roadway Tunneling for Utility Placement, up to 12" Diameter | LF | |
| Material Handling | |||
| C02G | Maintenance and Reconstruction of SHOULDERS using existing on-site materials only | LF | |
| C02H | Maintenance and reconstruction of ditches using existing, on-site materials only | LF | |
| C02J | Common Excavation | CY | |
| C02K | Rock Excavation | CY | |
| C02L | Excavation of Unsuitable Materials | CY | |
| C02M | Off-Base Material Disposal | CY | |
| C02N | Select Fill Material | CY | |
| C02P | Raise or Lower Utility Covers | EA | |
| Gates, Walls, and Fencing | |||
| C02Q | 8' Chain Link Fence | LF | |
| C02R | 3 Fencing Wire outriggers | LF | |
| C02S | 8' Pedestrian Gate | LF | |
| C02T | 8' Rolling Vehicle Gate | LF | |
| C02U | 8' Vehicle Swing Gate | LF | |
| C02V | 8' Heavy-Duty Vehicle Swing Gate | LF | |
| C02W | CMU wall, 2' High, split-face block | LF | |
| C02X | Tortoise Fence, Erection and Removal per plan provided by EM | LF | |
| C02Y | Construction of Protective Berms 95% compacted cohesive soil, 8" lifts, graded to smooth finish | CY | |
| C02Z | K-RAILS, for use during construction, installation and removal | LF | |
| C030 | Reduced Height airfield barriers, for use during construction, installation and removal | LF | |
| Lights and Signage | |||
| C031 | New Installation of Regulatory and Warning Signs, including single post | EA | |
| C032 | Directional Signs, sign-face manufacture and installation on existing posts. Type III or Higher micro prismatic reflective sign panels. ASTM D4956-13 and AASHTO M 268-13. | SF | |
| C033 | Remove and Replace Standard Signs on existing posts. Type III or Higher micro prismatic reflective sign panels. ASTM D4956-13 and AASHTO M 268-13. | EA | |
| C034 | Steel Breakaway Sign posts, 2" square, frangibly mounted up to 10' above grade. Anodized brown iaw the Edwards Base Design Standards. ASTM A653/A653M, ASTM A1011/A1011M, ASTM A123/A123M. | EA | |
| C035 | Treated Wooden 8"x8" Sign Posts, up to 20' above grade Painted brown iaw the Edwards Base Design Standards. ASTM D4444, AWPA U1, AWPA. | EA | |
| C036 | Lighting or Utility Pole, breakaway, up to 40' above grade (To Include Alumin. Pole, One Arm Bracket, Up To 6' Deep Conc Base, Wire, and Conduit) | EA | |
| C037 | Single LED Luminaire | EA | |
| C038 | Double LED Luminaire | EA | |
| Joint Repair & Rubber Removal | |||
| C039 | Silicone Joint Repair | LF | |
| C03A | Jet Fuel Resistant Joint Repair (DLA SS-S-200) | LF | |
| C03B | Compression Joint Seal | LF | |
| C03C | Airfield Rubber Removal - WATER | SF | |
| Demolition and Disposal | |||
| C03D | Demo Curb and Gutter | LF | |
| C03E | Demo Asphalt | CY | |
| C03F | Demo Concrete | CY | |
| Guardrails and Barriers | |||
| C03G | Guardrails | LF | |
| C03H | TL3 Energy Absorbing Barrier Ends | EA | |
| C03J | TL2 Energy Absorbing Barrier Ends | EA | |
| C03K | Non-Energy Absorbing Gating Ends | EA | |
| C03L | Energy Absorbing Barrels, Installed and Filled | EA | |
| C03M | Temporary, Changeable Message Signage for Traffic Control | DAY | |
| FOD Control | |||
| C03N | Manual FOD Control | HR | |
| C03P | Mechanical FOD Control | HR | |
| Non-Prepriced Items | |||
| C03Q | Non-Priced Item (To Be Negotiated Per Task Order) | EA | |
| TOTAL |
See FAR 2.101 and 3.104
&"Arial,Regular"&8FA9301-16-R-0011 PAVING ID/IQ SOLICITATION
ATTACHMENT 7 (L-1)
ELIN PRICING TEMPLATE (YEAR 3) &"Arial,Regular"&8FOR OFFICIAL USE ONLY
Year 4
| FA9301-16-R-0011 PAVING ID/IQ SOLITICATION | |||
| EXHIBIT LINE ITEM NUMBER (ELIN) PRICING TEMPLATE | |||
| YEAR 4 | |||
| Offeror Name: | |||
| ELIN | DESCRIPTION | UNIT OF MEASURE | PROPOSED PRICE |
| Sub-Base Course | |||
| D001 | Each 6'' of Sub-base preparation | SY | |
| D002 | Each added inch of Sub-base preparation | SY | |
| Base Course | |||
| D003 | 6'' Base | SY | |
| D004 | Added Base Inch 1"-5" | SY | |
| ACC Pavement | |||
| D005 | Each 3'' AC (64/28 Polymer Modified Mix) | SY | |
| D006 | Airfield Roadways, Each 3'' AC (64/28 Polymer Modified Mix, no RAP) | SY | |
| D007 | Airfield Shoulders, Each 3'' AC (64/28 Polymer Modified Mix, no RAP) | SY | |
| D008 | Each Added Inch (64/28 Polymer Modified Mix) | SY | |
| D009 | Airfield Roadways, Each Added Inch (64/28 Polymer Modified Mix, no RAP) | SY | |
| D00A | Airfield Shoulders, Each Added Inch (64/28 Polymer Modified Mix, no RAP) | SY | |
| D00B | Airfield - Load Bearing, Each 3'' AC (64/28 Polymer Modified Mix, no RAP) | SY | |
| D00C | Airfield - Load-Bearing Each Added Inch (64/28 Polymer Modified Mix, no RAP) | SY | |
| ACC Milling | |||
| D00D | Mill ACC, first inch | SY | |
| D00E | Milling, each added inch | SY | |
| ACC Pulverization | |||
| D00F | Pulverize ACC and incorporate on-site into base course, each 3" | SY | |
| D00G | Pulverize ACC and dispose off-base | SY | |
| Base and Sub-Base Reinforcement Measures | |||
| D00H | Cement Treated Soil Treatment @ 6% portland cement, top 8" inches | SY | |
| Bituminous Surface Treatment | |||
| D00J | Single Coat Treatment | SY | |
| D00K | Double Coat Treatment | SY | |
| ACC Spray Applications | |||
| D00L | Tack Coat | SY | |
| D00M | Fog Seals | SY | |
| D00N | Prime Coat | SY | |
| D00P | GSB-88 Rejuvenator | SY | |
| ACC Crack Seal | |||
| D00Q | ACC Crack Seal, Wide Cracks (1'' to 4'') | LF | |
| D00R | ACC Crack Seal, Medium Cracks (1/2" to 1'') | LF | |
| D00S | ACC Crack Seal, Narrow Cracks (1/16" to 1/2'') | LF | |
| Slurry Seal | |||
| D00T | Single Application, with Tack Coat | SY | |
| D00U | Single Application, without Tack Coat | SY | |
| ACC Patching | |||
| D00V | ACC Patch < 100SY | SY | |
| D00W | ACC Patch >100SY | SY | |
| Roadway and Airfield Markings | |||
| D00X | Roadway Striping, 4'' Line, with A/F Type 1 Beads | SF | |
| D00Y | Roadway Striping, 4'' Line, with A/F Type 4 Beads | SF | |
| D00Z | Roadway MARKING REFLECTIVE with A/F Type 1 Beads | SF | |
| D010 | Roadway MARKING REFLECTIVE with A/F Type 4 Beads | SF | |
| D011 | Roadway Marking, Thermoplastic Material | SF | |
| D012 | Airfield Striping, 30" Line total - on Full-Width Black Background, with A/F Type 1 Beads | LF | |
| D013 | Airfield Striping, 30" Line total - on Full-Width Black Background, with A/F Type 3 Beads | LF | |
| D014 | Airfield Markings, with A/F Type 1 Beads | SF | |
| D015 | Airfield Markings, with A/F Type 3 Beads | SF | |
| D016 | Airfield, Thermoplastic Material Airfield Rated | SF | |
| D017 | Non-Lead-Based Paint Removal | SF | |
| D018 | Temporary Construction-use Reflectors | EA | |
| D019 | Permanent, Type D Two-Way Reflective Markers | EA | |
| D01A | Permanent, Type G One-Way Reflectors | EA | |
| D01B | Rumble Strips, rubberized material purchased and installed post-construction | EA | |
| D01C | Rumble Strips, created in ACC at construction | LF | |
| Concrete Work | |||
| D01D | Reinforced PCC Airfield, 650 psi Flexural Strength (ASR Free Aggregate) | CY | |
| D01E | Unreinforced PCC Airfield, 650 psi Flexural Strength (ASR Free Aggregate) | CY | |
| D01F | PCC Roadway, Roadway Use, Slipform | CY | |
| D01G | Reinforced Concrete Pad, Formed and Cast in-place | CY | |
| D01H | Reinforced PCC Headwall, Formed and Cast-in-place | CY | |
| D01J | PCC Valley Gutters | CF | |
| D01K | PCC Spandrels | CF | |
| D01L | 6" Curb with 18" Gutter | LF | |
| D01M | 6" Curb, Curb Only | LF | |
| D01N | Sidewalks 6" thick, unreinforced, 5' wide | LF | |
| D01P | ADA Entrances/Exits, Constructed in Existing Sidewalks, including demolition and disposal | EA | |
| D01Q | Corner-Wide ADA Entrances/Exits, Constructed in Existing Sidewalks, including demolition and disposal | EA | |
| D01R | ADA Entrances/Exits, with new Sidewalk Construction | EA | |
| D01S | Corner-Wide ADA Entrances/Exits, with new Sidewalk Construction | EA | |
| D01T | Handicap Ramp 1:12 Maximum, 5' wide, with handrail both sides | LF | |
| D01U | PCC Crack Seal, Rout and Seal Includes all preparation and pressure-applied epoxy sealant | LF | |
| D01V | Spall Repair, PCC Pavement | SF | |
| Culverts | |||
| D01W | Culvert, 30'' Remove Only | LF | |
| D01X | Culvert, 36'' Remove Only | LF | |
| D01Y | Culvert, 30'' CMP Install Only including end treatment | LF | |
| D01Z | Culvert, 36'' CMP Install Only including end treatment | LF | |
| D020 | Culvert, 24'' RCP Install Only including end treatment | LF | |
| D021 | Culvert, 30'' RCP Install Only including end treatment | LF | |
| D022 | Culvert, 36'' RCP Install Only including end treatment | LF | |
| Handling of Government Furnished Material | |||
| D023 | Material Trucking | TON/MI | |
| D024 | On-Base Bulk Material Loading & Unloading | CY | |
| D025 | Placement of government furnished base 6" | SY | |
| D026 | Each added inch of government furnished base 1"-5" | SY | |
| D027 | Placement of government furnished Sub-base 6" | SY | |
| D028 | Each added inch of goverment furnished Sub-base | SY | |
| Professional and Speciality Services | |||
| D029 | Exploratory Drilling per hole, in earth or AC, each foot | EA | |
| D02A | Exploratory Drilling, per hole, in rock or through PCC, each 6'' deep | EA | |
| D02B | Drive Sample, Testing, and a Report | EA | |
| D02C | Soil Sampling, Testing, and a Report | EA | |
| D02D | 2-Man Survey Team, In-Field Marking and Report (These items are for additional surveying, as required, above and beyond a standard paving project. Surveying incidental to a standard paving project is to be included in the line items associated with the standard paving project.) | HR | |
| D02E | Pot-holing for utilities (These items are for additional pot-holing, as required, above and beyond a standard paving project. Pot-holing incidental to a standard paving project is to be included in the line items associated with the standard paving project.) | HR | |
| D02F | Under-Roadway Tunneling for Utility Placement, up to 12" Diameter | LF | |
| Material Handling | |||
| D02G | Maintenance and Reconstruction of SHOULDERS using existing on-site materials only | LF | |
| D02H | Maintenance and reconstruction of ditches using existing, on-site materials only | LF | |
| D02J | Common Excavation | CY | |
| D02K | Rock Excavation | CY | |
| D02L | Excavation of Unsuitable Materials | CY | |
| D02M | Off-Base Material Disposal | CY | |
| D02N | Select Fill Material | CY | |
| D02P | Raise or Lower Utility Covers | EA | |
| Gates, Walls, and Fencing | |||
| D02Q | 8' Chain Link Fence | LF | |
| D02R | 3 Fencing Wire outriggers | LF | |
| D02S | 8' Pedestrian Gate | LF | |
| D02T | 8' Rolling Vehicle Gate | LF | |
| D02U | 8' Vehicle Swing Gate | LF | |
| D02V | 8' Heavy-Duty Vehicle Swing Gate | LF | |
| D02W | CMU wall, 2' High, split-face block | LF | |
| D02X | Tortoise Fence, Erection and Removal per plan provided by EM | LF | |
| D02Y | Construction of Protective Berms 95% compacted cohesive soil, 8" lifts, graded to smooth finish | CY | |
| D02Z | K-RAILS, for use during construction, installation and removal | LF | |
| D030 | Reduced Height airfield barriers, for use during construction, installation and removal | LF | |
| Lights and Signage | |||
| D031 | New Installation of Regulatory and Warning Signs, including single post | EA | |
| D032 | Directional Signs, sign-face manufacture and installation on existing posts. Type III or Higher micro prismatic reflective sign panels. ASTM D4956-13 and AASHTO M 268-13. | SF | |
| D033 | Remove and Replace Standard Signs on existing posts. Type III or Higher micro prismatic reflective sign panels. ASTM D4956-13 and AASHTO M 268-13. | EA | |
| D034 | Steel Breakaway Sign posts, 2" square, frangibly mounted up to 10' above grade. Anodized brown iaw the Edwards Base Design Standards. ASTM A653/A653M, ASTM A1011/A1011M, ASTM A123/A123M. | EA | |
| D035 | Treated Wooden 8"x8" Sign Posts, up to 20' above grade Painted brown iaw the Edwards Base Design Standards. ASTM D4444, AWPA U1, AWPA. | EA | |
| D036 | Lighting or Utility Pole, breakaway, up to 40' above grade (To Include Alumin. Pole, One Arm Bracket, Up To 6' Deep Conc Base, Wire, and Conduit) | EA | |
| D037 | Single LED Luminaire | EA | |
| D038 | Double LED Luminaire | EA | |
| Joint Repair & Rubber Removal | |||
| D039 | Silicone Joint Repair | LF | |
| D03A | Jet Fuel Resistant Joint Repair (DLA SS-S-200) | LF | |
| D03B | Compression Joint Seal | LF | |
| D03C | Airfield Rubber Removal - WATER | SF | |
| Demolition and Disposal | |||
| D03D | Demo Curb and Gutter | LF | |
| D03E | Demo Asphalt | CY | |
| D03F | Demo Concrete | CY | |
| Guardrails and Barriers | |||
| D03G | Guardrails | LF | |
| D03H | TL3 Energy Absorbing Barrier Ends | EA | |
| D03J | TL2 Energy Absorbing Barrier Ends | EA | |
| D03K | Non-Energy Absorbing Gating Ends | EA | |
| D03L | Energy Absorbing Barrels, Installed and Filled | EA | |
| D03M | Temporary, Changeable Message Signage for Traffic Control | DAY | |
| FOD Control | |||
| D03N | Manual FOD Control | HR | |
| D03P | Mechanical FOD Control | HR | |
| Non-Prepriced Items | |||
| D03Q | Non-Priced Item (To Be Negotiated Per Task Order) | EA | |
| TOTAL |
See FAR 2.101 and 3.104
&"Arial,Regular"&8FA9301-16-R-0011 PAVING ID/IQ SOLICITATION
ATTACHMENT 7 (L-1)
ELIN PRICING TEMPLATE (YEAR 4) &"Arial,Regular"&8FOR OFFICIAL USE ONLY
Year 5
| FA9301-16-R-0011 PAVING ID/IQ SOLITICATION | |||
| EXHIBIT LINE ITEM NUMBER (ELIN) PRICING TEMPLATE | |||
| YEAR 5 | |||
| Offeror Name: | |||
| ELIN | DESCRIPTION | UNIT OF MEASURE | PROPOSED PRICE |
| Sub-Base Course | |||
| E001 | Each 6'' of Sub-base preparation | SY | |
| E002 | Each added inch of Sub-base preparation | SY | |
| Base Course | |||
| E003 | 6'' Base | SY | |
| E004 | Added Base Inch 1"-5" | SY | |
| ACC Pavement | |||
| E005 | Each 3'' AC (64/28 Polymer Modified Mix) | SY | |
| E006 | Airfield Roadways, Each 3'' AC (64/28 Polymer Modified Mix, no RAP) | SY | |
| E007 | Airfield Shoulders, Each 3'' AC (64/28 Polymer Modified Mix, no RAP) | SY | |
| E008 | Each Added Inch (64/28 Polymer Modified Mix) | SY | |
| E009 | Airfield Roadways, Each Added Inch (64/28 Polymer Modified Mix, no RAP) | SY | |
| E00A | Airfield Shoulders, Each Added Inch (64/28 Polymer Modified Mix, no RAP) | SY | |
| E00B | Airfield - Load Bearing, Each 3'' AC (64/28 Polymer Modified Mix, no RAP) | SY | |
| E00C | Airfield - Load-Bearing Each Added Inch (64/28 Polymer Modified Mix, no RAP) | SY | |
| ACC Milling | |||
| E00D | Mill ACC, first inch | SY | |
| E00E | Milling, each added inch | SY | |
| ACC Pulverization | |||
| E00F | Pulverize ACC and incorporate on-site into base course, each 3" | SY | |
| E00G | Pulverize ACC and dispose off-base | SY | |
| Base and Sub-Base Reinforcement Measures | |||
| E00H | Cement Treated Soil Treatment @ 6% portland cement, top 8" inches | SY | |
| Bituminous Surface Treatment | |||
| E00J | Single Coat Treatment | SY | |
| E00K | Double Coat Treatment | SY | |
| ACC Spray Applications | |||
| E00L | Tack Coat | SY | |
| E00M | Fog Seals | SY | |
| E00N | Prime Coat | SY | |
| E00P | GSB-88 Rejuvenator | SY | |
| ACC Crack Seal | |||
| E00Q | ACC Crack Seal, Wide Cracks (1'' to 4'') | LF | |
| E00R | ACC Crack Seal, Medium Cracks (1/2" to 1'') | LF | |
| E00S | ACC Crack Seal, Narrow Cracks (1/16" to 1/2'') | LF | |
| Slurry Seal | |||
| E00T | Single Application, with Tack Coat | SY | |
| E00U | Single Application, without Tack Coat | SY | |
| ACC Patching | |||
| E00V | ACC Patch < 100SY | SY | |
| E00W | ACC Patch >100SY | SY | |
| Roadway and Airfield Markings | |||
| E00X | Roadway Striping, 4'' Line, with A/F Type 1 Beads | SF | |
| E00Y | Roadway Striping, 4'' Line, with A/F Type 4 Beads | SF | |
| E00Z | Roadway MARKING REFLECTIVE with A/F Type 1 Beads | SF | |
| E010 | Roadway MARKING REFLECTIVE with A/F Type 4 Beads | SF | |
| E011 | Roadway Marking, Thermoplastic Material | SF | |
| E012 | Airfield Striping, 30" Line total - on Full-Width Black Background, with A/F Type 1 Beads | LF | |
| E013 | Airfield Striping, 30" Line total - on Full-Width Black Background, with A/F Type 3 Beads | LF | |
| E014 | Airfield Markings, with A/F Type 1 Beads | SF | |
| E015 | Airfield Markings, with A/F Type 3 Beads | SF | |
| E016 | Airfield, Thermoplastic Material Airfield Rated | SF | |
| E017 | Non-Lead-Based Paint Removal | SF | |
| E018 | Temporary Construction-use Reflectors | EA | |
| E019 | Permanent, Type D Two-Way Reflective Markers | EA | |
| E01A | Permanent, Type G One-Way Reflectors | EA | |
| E01B | Rumble Strips, rubberized material purchased and installed post-construction | EA | |
| E01C | Rumble Strips, created in ACC at construction | LF | |
| Concrete Work | |||
| E01D | Reinforced PCC Airfield, 650 psi Flexural Strength (ASR Free Aggregate) | CY | |
| E01E | Unreinforced PCC Airfield, 650 psi Flexural Strength (ASR Free Aggregate) | CY | |
| E01F | PCC Roadway, Roadway Use, Slipform | CY | |
| E01G | Reinforced Concrete Pad, Formed and Cast in-place | CY | |
| E01H | Reinforced PCC Headwall, Formed and Cast-in-place | CY | |
| E01J | PCC Valley Gutters | CF | |
| E01K | PCC Spandrels | CF | |
| E01L | 6" Curb with 18" Gutter | LF | |
| E01M | 6" Curb, Curb Only | LF | |
| E01N | Sidewalks 6" thick, unreinforced, 5' wide | LF | |
| E01P | ADA Entrances/Exits, Constructed in Existing Sidewalks, including demolition and disposal | EA | |
| E01Q | Corner-Wide ADA Entrances/Exits, Constructed in Existing Sidewalks, including demolition and disposal | EA | |
| E01R | ADA Entrances/Exits, with new Sidewalk Construction | EA | |
| E01S | Corner-Wide ADA Entrances/Exits, with new Sidewalk Construction | EA | |
| E01T | Handicap Ramp 1:12 Maximum, 5' wide, with handrail both sides | LF | |
| E01U | PCC Crack Seal, Rout and Seal Includes all preparation and pressure-applied epoxy sealant | LF | |
| E01V | Spall Repair, PCC Pavement | SF | |
| Culverts | |||
| E01W | Culvert, 30'' Remove Only | LF | |
| E01X | Culvert, 36'' Remove Only | LF | |
| E01Y | Culvert, 30'' CMP Install Only including end treatment | LF | |
| E01Z | Culvert, 36'' CMP Install Only including end treatment | LF | |
| E020 | Culvert, 24'' RCP Install Only including end treatment | LF | |
| E021 | Culvert, 30'' RCP Install Only including end treatment | LF | |
| E022 | Culvert, 36'' RCP Install Only including end treatment | LF | |
| Handling of Government Furnished Material | |||
| E023 | Material Trucking | TON/MI | |
| E024 | On-Base Bulk Material Loading & Unloading | CY | |
| E025 | Placement of government furnished base 6" | SY | |
| E026 | Each added inch of government furnished base 1"-5" | SY | |
| E027 | Placement of government furnished Sub-base 6" | SY | |
| E028 | Each added inch of goverment furnished Sub-base | SY | |
| Professional and Speciality Services | |||
| E029 | Exploratory Drilling per hole, in earth or AC, each foot | EA | |
| E02A | Exploratory Drilling, per hole, in rock or through PCC, each 6'' deep | EA | |
| E02B | Drive Sample, Testing, and a Report | EA | |
| E02C | Soil Sampling, Testing, and a Report | EA | |
| E02D | 2-Man Survey Team, In-Field Marking and Report (These items are for additional surveying, as required, above and beyond a standard paving project. Surveying incidental to a standard paving project is to be included in the line items associated with the standard paving project.) | HR | |
| E02E | Pot-holing for utilities (These items are for additional pot-holing, as required, above and beyond a standard paving project. Pot-holing incidental to a standard paving project is to be included in the line items associated with the standard paving project.) | HR | |
| E02F | Under-Roadway Tunneling for Utility Placement, up to 12" Diameter | LF | |
| Material Handling | |||
| E02G | Maintenance and Reconstruction of SHOULDERS using existing on-site materials only | LF | |
| E02H | Maintenance and reconstruction of ditches using existing, on-site materials only | LF | |
| E02J | Common Excavation | CY | |
| E02K | Rock Excavation | CY | |
| E02L | Excavation of Unsuitable Materials | CY | |
| E02M | Off-Base Material Disposal | CY | |
| E02N | Select Fill Material | CY | |
| E02P | Raise or Lower Utility Covers | EA | |
| Gates, Walls, and Fencing | |||
| E02Q | 8' Chain Link Fence | LF | |
| E02R | 3 Fencing Wire outriggers | LF | |
| E02S | 8' Pedestrian Gate | LF | |
| E02T | 8' Rolling Vehicle Gate | LF | |
| E02U | 8' Vehicle Swing Gate | LF | |
| E02V | 8' Heavy-Duty Vehicle Swing Gate | LF | |
| E02W | CMU wall, 2' High, split-face block | LF | |
| E02X | Tortoise Fence, Erection and Removal per plan provided by EM | LF | |
| E02Y | Construction of Protective Berms 95% compacted cohesive soil, 8" lifts, graded to smooth finish | CY | |
| E02Z | K-RAILS, for use during construction, installation and removal | LF | |
| E030 | Reduced Height airfield barriers, for use during construction, installation and removal | LF | |
| Lights and Signage | |||
| E031 | New Installation of Regulatory and Warning Signs, including single post | EA | |
| E032 | Directional Signs, sign-face manufacture and installation on existing posts. Type III or Higher micro prismatic reflective sign panels. ASTM D4956-13 and AASHTO M 268-13. | SF | |
| E033 | Remove and Replace Standard Signs on existing posts. Type III or Higher micro prismatic reflective sign panels. ASTM D4956-13 and AASHTO M 268-13. | EA | |
| E034 | Steel Breakaway Sign posts, 2" square, frangibly mounted up to 10' above grade. Anodized brown iaw the Edwards Base Design Standards. ASTM A653/A653M, ASTM A1011/A1011M, ASTM A123/A123M. | EA | |
| E035 | Treated Wooden 8"x8" Sign Posts, up to 20' above grade Painted brown iaw the Edwards Base Design Standards. ASTM D4444, AWPA U1, AWPA. | EA | |
| E036 | Lighting or Utility Pole, breakaway, up to 40' above grade (To Include Alumin. Pole, One Arm Bracket, Up To 6' Deep Conc Base, Wire, and Conduit) | EA | |
| E037 | Single LED Luminaire | EA | |
| E038 | Double LED Luminaire | EA | |
| Joint Repair & Rubber Removal | |||
| E039 | Silicone Joint Repair | LF | |
| E03A | Jet Fuel Resistant Joint Repair (DLA SS-S-200) | LF | |
| E03B | Compression Joint Seal | LF | |
| E03C | Airfield Rubber Removal - WATER | SF | |
| Demolition and Disposal | |||
| E03D | Demo Curb and Gutter | LF | |
| E03E | Demo Asphalt | CY | |
| E03F | Demo Concrete | CY | |
| Guardrails and Barriers | |||
| E03G | Guardrails | LF | |
| E03H | TL3 Energy Absorbing Barrier Ends | EA | |
| E03J | TL2 Energy Absorbing Barrier Ends | EA | |
| E03K | Non-Energy Absorbing Gating Ends | EA | |
| E03L | Energy Absorbing Barrels, Installed and Filled | EA | |
| E03M | Temporary, Changeable Message Signage for Traffic Control | DAY | |
| FOD Control | |||
| E03N | Manual FOD Control | HR | |
| E03P | Mechanical FOD Control | HR | |
| Non-Prepriced Items | |||
| E03Q | Non-Priced Item (To Be Negotiated Per Task Order) | EA | |
| TOTAL |
&8FOR OFFICIAL USE ONLY
See FAR 2.101 and 3.104
&"Arial,Regular"&8FA9301-16-R-0011 PAVING ID/IQ SOLICITATION
ATTACHMENT 7 (L-1)
ELIN PRICING TEMPLATE (YEAR 5) &"Arial,Regular"&8FOR OFFICIAL USE ONLY
File details come from the government source that posted it. Updated .