Attachment 13 - SOW attach Volume 2 Part 2.pdf
PDF 19 MB Posted
- Attached to
- Y1DA--538-21-701 EHRM Infrastructure Upgrades Construction Chillicothe, OH (VA-23-00066755)
- Solicitation number
- 36C77623B0058
About this file
This attachment is a statement of work for infrastructure upgrades to the Chillicothe VA Medical Center in Ohio. The statement of work details the required construction services, which include upgrades to the medical center's electrical systems, HVAC systems, and information technology infrastructure to support the electronic health records modernization initiative. Offerors must have experience in healthcare facility construction and renovations. The solicitation number for this opportunity is 36C77623B0058, issued by the Department of Veterans Affairs Technology Acquisition Center. The response due date is July 21, 2021 and the period of performance for awarded contracts is 365 days.
View the file
Other files
Show 40 more
Latest 50 of 65 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
DN
UP
DN
UP
DN
DN
DN
DN
DN
UP
REF.
Tech. Room
G-322A
Elec. Clos.
G-328
Tele Clos
G-202
Copier Storage
G-312
Exam Room
G-316
Corridor
Corridor
Office
G-322
Office
G-323
Corridor
Waiting
G-343A
Wheelchair Storage
G-343D CT Power Equipment
G-345G
Corridor
CT Scan Room
G-345F
Corridor
G-550
Shell Space
G-524
Elect. Room
G-500C
TR
G-500D
Corridor
G194
Clerks
G160A
Conference Room
G182
Toilet
G163
Unisex-Specimen
G161
Elect. Room
G160G
TR
G160H
MH Clinic
G-206
Social Worker
G-204
Corridor
BC007
MH Conference Room
G-200
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:3
A
M
031-MD100
MECHANICAL DEMOLITION PLAN -
GROUND
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 031
CHILLICOTHE
VAMC
Approved: Owner
1/16" = 1'-0"
BLDG 31 - GROUND - MECHANICAL DEMOLITION PLAN
D R A W I N G N O T E S :
1 CHECK EXISTING SPLIT SYSTEM FOR PROPER FUNCTIONING. DEMOLISH IF DOESN'T MEET REQUIREMENT AND REPLACE
WITH SPLIT SYSTEM AS SCHEDULED.
2 DEMOLISH EXISTING RADIATOR, CONNECTED PIPING, SUPPORTS, WIRING AND CONTROLS.
3 REMOVE EXISTING SUPPLY DIFFUSER.
No. Revisions: Date:
CONSTRUCTION DOCUMENTS - 95% SUBMITTAL 03/17/2023
CONSTRUCTION DOCUMENTS - 95% 04/14/2023
TR
1-210
Storage
1-129
Mechanical
F212
Elect. Room
F202
TR
F204
Group Therapy
F209
Blood Draw
1-211
Corridor
1C2
Corridor
1C1 Storage
1-211A
Vacant
1-209
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:4
A
M
031-MD101
MECHANICAL DEMOLITION PLAN -
FIRST FLOOR
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 031
CHILLICOTHE
VAMC
Approved: Owner
1/16" = 1'-0"
BLDG 31 - FIRST FLOOR - MECHANICAL DEMOLITION PLAN
D R A W I N G N O T E S :
1 EXISTING EQUIPMENT TO REMAIN.
No. Revisions: Date:
UP
DN
UP
DN
DN
DN
DN
DN
UP
REF.
E M
E M
EM
EM
EM
EM (E)
EM (E)EM (E)
(E
46" (E)
(E)
E M
E
E M
E
(E)
(E)
EM
E M
E M
E M
E M
EM
E M
EM
E M
EM
T
T
P
E
MEM
EM
E M
E
MEM
P
P
ODU-11
1 ODU-1
1/2"ø RCD UP 1/2"ø RRP UP 3/8"ø RSP UP
1ODU-1
1ODU-2
3/8"ø RSP 1/2"ø RRP 1/2"ø RCD
2IDU-2
3/8"ø RSP UP 1/2"ø RRP UP 3/8"ø RSP UP 1/2"ø RRP UP
1/2"ø RRP UP 3/8"ø RSP UP 1/2"ø RRP UP 3/8"ø RSP UP
2 IDU-2
ODU-2
1/2"ø RCD 1/2"ø RRP 3/8"ø RSP
SA
50 CFM
RA
50 CFM
3 3
IDU-22
ODU-2 1
Corridor
G-550
Elect. Room
G-500C
Shell Space
G-524
TR
G-500D
CT Scan Room
G-345F
Corridor
Corridor
Corridor
CT Power Equipment
G-345G
Wheelchair Storage
G-343D Waiting
G-343A
Social Worker
G-204
MH Clinic
G-206
Tele Clos
G-202
MH Conference Room
G-200
Corridor
BC007
Corridor
G194
Conference Room
G182
Clerks
G160A
TR
G182A
Elect. Room
G160G
Unisex-Specimen
G161
Toilet
G163
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:5
A
M
031-MH100
MECHANICAL NEW WORK PLAN -
GROUND
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 031
CHILLICOTHE
VAMC
Approved: Owner
1/16" = 1'-0"
BLDG 31 - GROUND - MECHANICAL NEW WORK PLAN
D R A W I N G N O T E S :
1 INSTALL NEW HEAT PUMP ON A CONCRETE PAD AND SUPPLY PIPING BACK TO TELECOMMUNICATION ROOM.
2 PROVIDE NEW SPLIT UNIT SYSTEM, ASSOCIATED PIPING, CONTROLS, SUPPORTS AND WIRING.
3 RE BALANCE EXISTING VAV BOXES AND EXISTING RETURN GRILLES TO NEW AIRFLOW SHOW ON DRAWING.
4 PROVIDE NEW DRIP PANS UNDER PIPING DIRECTLY OVER NEW ELECTRICAL EQUIPMENT.
5 DRILL HOLES IN THE WALL TO RUN REFRIGERANT AND CONDENSATE DRAINAGE PIPING TO THE HEAT PUMP OUTSIDE.
6 PROVIDE NEW THERMOSTAT FOR TELECOMMUNICATION ROOM.
No. Revisions: Date:
E M
EM
EM
E M
E M
EM
E M
EM
E M
EM
EM
T
E M
TR
1-210
3/8"ø RSP 1/2"ø RRP 3/8"ø RSP 1/2"ø RRP
1/2"ø RCD
1/2"ø RCD
1 IDU-1
3 SA
30 CFM
EA
30 CFM
1IDU-1
1/2"ø RRP DN 3/8"ø RSP DN
1/2"ø RCD DN
1/2"ø RCD DN
1/2"ø RRP DN
3/8"ø RSP DN
1/2"ø RRP UP & DN
3/8"ø RSP UP & DN
1/2"ø RRP UP & DN 3/8"ø RSP UP & DN
Storage
1-211A
Blood Draw
1-211
Corridor
1C1
Corridor
1C2
Vacant
1-209
HAC
1-213
Mechanical
F212
Elect. Room
F202
TR
F204
Group Therapy
F209
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:0
A
M
031-MH101
MECHANICAL NEW WORK PLAN -
FIRST FLOOR
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 031
CHILLICOTHE
VAMC
Approved: Owner
1/16" = 1'-0"
BLDG 31 - FIRST FLOOR - MECHANICAL NEW WORK PLAN
D R A W I N G N O T E S :
1 PROVIDE NEW SPLIT UNIT SYSTEM, ASSOCIATED PIPING, CONTROLS, SUPPORTS AND WIRING.
2 PROVIDE NEW THERMOSTAT FOR TELECOMMUNICATION ROOM.
3 RE BALANCE EXISTING VAV BOXES AND EXISTING RETURN GRILLES TO NEW AIRFLOW SHOW ON DRAWING.
4 ROUTE NEW CONDENSATE DRAIN PIPING TO MOP SINK IN EXISTING HAC CLOSET.
No. Revisions: Date:
M H
2D /1
V 46" MH2D/1V
2D/1V 2D/1V
2D/1V 2D/1V
M H
2D /1
V
M
H 2D
/1 V
46" MH2D/1V
M H
2D /1
V
M H
2D /1
V
M H
W
2D/1V
46" MH2D/1V
M H
W
46" MH
W
M H
2D /1
V
M H
2D /1
V
M H
2D /1
V
AP
AP AP
M H
2D /1
V
M H
2D /1
V
46" MH
2D/1V
M H
W
46" MH2D/1V
3D
46" MH
2D/1V
AP
M H
3D
M
H 2D
/1 V
M H
W
2D /1
V
2D /1
V
M H
2D /1
V
46" MH 3D
AP
46" MHWW
3D
W
2D/1V 2D/1V
2D /1
V
2D /1
V
3D
3DW
2D/1V
2D/1V
3D
46" MH
2D/1V
W
W
M H
2D /1
V
46" MH
2D/1V
AP
AP
M H
2D /1
V
M H
2D /1
V
46" MH 3D
2D/1V2D/1V
AP
46" MH
2D/1V
AP
46" MH
2D/1V
M H
2D /1
V
3D
46" MH
2D/1V
46" MH
2D/1V
AP
AP2D/1V
M H
2D /1
VW
3D
2D/1V
2D /1
V 1V
2D/1V
2D /1
V
46" MH
2D/1V
46" MH
2D/1V
46" MH
2D/1V
3D
AP
2D /1
V
2D/1V
3D
W
2D/1V
1V
3D 2D/1V
W
W
2D /1
V
2D/1V
2D/1V
2D/1V
W
2D/1V
2D/1V
2D /1
V
2D /1
V
2D/1V
AP
3D 3D
2D/1V
2D/1V 2D
/1 V
2D /1
V
2D /1
V
2D/1V
2D /1
V
2D /1
V
2D/1V
2D /1
V
2D /1
V
2D/1V
2D /1
V 2D
/1 V
2D/1V
2D/1V
3D
W
2D /1
V
2D /1
V
2D/1V
2D/1V
M H
2D /1
V
2D/1V
2D/1V
2D/1V
46" MH
2D/1V
1D
3D
2D/1V
46" MH
2D/1V
2D /1
V 2D
/1 V
2D/1V
2D/1V
AP
AP
46" MH
2D/1V
2D/1V
2V
2D /1
V
2D /1
V 2D
/1 V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V1V
AP
2D/1V
2D/1V
2D/1V
2D/1V
2D /1
V
2D /1
V
2D /1
V
2D /1
V
2D/1V
AP
AP
1D
2D/1V
2D/1V
2D /1
V
46" MH
2D/1V
AP
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
46" MH
2D/1V
2D/1V
2D/1V 1V
2D/1V
AP
AP
1V 2D /1
V
2D/1V
2D/1V
2V
2D/1V
2D /1
V1V
AP
AP
T
IDU-1
TR
2-207A
1/2"ø RCD
1/2"ø RRP 3/8"ø RSP
1/2"ø RCD 1/2"ø RRP 3/8"ø RSP
SA
45 CFM
RA
45 CFM
Vacant
2-206
Corridor
2C002
Pharmacy Secretary/ Clerk
2-207
Chief, Pharmacy
2-207B
Stair #4
S-204
Corridor
2C001
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:1
A
M
031-MH102
MECHANICAL NEW WORK PLAN -
SECOND FLOOR
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 031
CHILLICOTHE
VAMC
Approved: Owner
1/8" = 1'-0"
BLDG 31 - SECOND FLOOR - MECHANICAL NEW WORK PLAN
D R A W I N G N O T E S :
1 PROVIDE NEW SPLIT UNIT SYSTEM, ASSOCIATED PIPING, CONTROLS, SUPPORTS AND WIRING.
2 DRILL HOLES IN THE WALL TO RUN REFRIGERANT AND CONDENSATE DRAINAGE PIPING TO THE HEAT PUMP OUTSIDE.
3 PROVIDE NEW THERMOSTAT FOR TELECOMMUNICATION ROOM.
4 RE BALANCE EXISTING VAV BOXES AND EXISTING RETURN GRILLES TO NEW AIRFLOW SHOW ON DRAWING.
No. Revisions: Date:
TR
BC102
Storage
BC108
Soiled Linen
BA102
Equip Storage
BC101
Corridor
BCC1
Corridor
BC108F
Elevator Machine Room
BC103
Recreational Therapy
BC104
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:1
A
M
035-MD100
MECHANICAL DEMOLITION PLAN -
BASEMENT
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 035
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 35 - BASEMENT - MECHANICAL DEMOLITION PLAN
D R A W I N G N O T E S :
1 DEMOLISH EXISTING RADIATOR, CONNECTED PIPING, SUPPORTS, WIRING AND CONTROLS.
2 EXISTING EQUIPMENT TO REMAIN.
No. Revisions: Date:
D W
T
TR
1A109
Physician Assistant
1A108 Visitor Lounge
1A104
Space
BC107
Corridor
1AC1
Corridor
1BC1
Corridor
1CC1
Nurse Manager
1C101
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:2
A
M
035-MD101
MECHANICAL DEMOLITION PLAN -
FIRST FLOOR
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 035
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 35 - FIRST FLOOR - MECHANICAL DEMOLITION PLAN
D R A W I N G N O T E S :
1 DEMOLISH EXISTING RADIATOR, CONNECTED PIPING, SUPPORTS, WIRING AND CONTROLS.
2 EXISTING EQUIPMENT TO REMAIN.
No. Revisions: Date:
R E
F
T
TR
2A109
Nursing/ Break
2A104
Vistation Room
2B101
Space
1BC7
Corridor
2AC1
Fire Alarm Closet
2A106 Linen Chute
2A107
Visitation Room
2C101
Corridor
2CC1
Corridor
2BC1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:3
A
M
035-MD102
MECHANICAL DEMOLITION PLAN -
SECOND FLOOR
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 035
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 35 - SECOND FLOOR - MECHANICAL DEMOLITION PLAN
D R A W I N G N O T E S :
1 DEMOLISH EXISTING RADIATOR, CONNECTED PIPING, SUPPORTS, WIRING AND CONTROLS.
2 EXISTING EQUIPMENT TO REMAIN.
No. Revisions: Date:
T
TR
3A109
Corridor
3AC1
Corridor
3BC1
NCCPAC Revenue Utilization Review Nurse
3B101
Health Behavior Coordinator
3A104
Physician Assistant
3A108
Social Worker
3C101
FA Clos
3A106
Corridor
3CC1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:3
A
M
035-MD103
MECHANICAL DEMOLITION PLAN -
THIRD FLOOR
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 035
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 35 - THIRD FLOOR - MECHANICAL DEMOLITION PLAN
D R A W I N G N O T E S :
1 DEMOLISH EXISTING RADIATOR, CONNECTED PIPING, SUPPORTS, WIRING AND CONTROLS.
2 EXISTING EQUIPMENT TO REMAIN.
No. Revisions: Date:
AP
AP
1D 3D 2D/1V3D 3D
2D/1V
2D/1V
1D
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V2D/1V
AP
3D3D
3D2D/1V3D
3D
2D/1V
2D/1V 3D
3D
3D
2D/1V
3D 3D2D/1V 3D
AP
AP
AP
AP
AP
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
W
2D/1V
2D/1V
2D/1V
2D/1V 2V
AP
AP
AP
AP
W 2D/1V
W
3D 3D
3D
3D 3D 3D
2D/1V 2D/1V
AP
AP
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D/1V
AP
AP
AP
3D3D3D3D
2D /1
V 2D
/1 V
2D /1
V
2D /1
V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
3D
3D
2D/1V
T
TR
BC102
ODU-2
ODU-2
IDU-2
3/8"ø RSP
1/2"ø RRP
1/2"ø RCD
3/8"ø RSP UP
1/2"ø RRP UP 1/2"ø RCD UP
1/2"ø RCD UP 3/8"ø RSP UP
1/2"ø RRP UP
1/2"ø RCD UP 3/8"ø RSP UP 1/2"ø RRP UP
Soiled Linen
BA102
Equip Storage
BC101
Corridor
BCC1
Corridor
BC108F
Storage
BC108
Recreational Therapy
BC104
Elevator Machine Room
BC103
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:4
A
M
035-MH100
MECHANICAL NEW WORK PLAN -
BASEMENT
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 035
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 35 - BASEMENT - MECHANICAL NEW WORK PLAN
D R A W I N G N O T E S :
1 INSTALL NEW HEAT PUMP ON A CONCRETE PAD AND SUPPLY PIPING BACK TO TELECOMMUNICATION ROOM.
2 PROVIDE NEW SPLIT UNIT SYSTEM, ASSOCIATED PIPING, CONTROLS, SUPPORTS AND WIRING.
3 PROVIDE NEW THERMOSTAT FOR TELECOMMUNICATION ROOM.
4 DRILL HOLES IN THE WALL TO RUN REFRIGERANT AND CONDENSATE DRAINAGE PIPING TO THE HEAT PUMP OUTSIDE.
No. Revisions: Date:
2D/1V
2D/1V
AP
2D/1V
2D/1V
W 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
W
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V 2D/1V
2D/1V2D/1V
2D/1V 2D/1V
2D/1V 2D
/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
AP
AP
AP
AP
AP
2D/1V
AP
AP
AP
2D/1V
2D/1V
2D/1V2D/1V
2D/1V
AP
AP
2D/1V
2D/1V 2D/1V
2D/1V
W
W
2D/1V
2D/1V 2D/1V
2D/1V
W W
2D/1V
2D/1V 2D/1V
2D/1V
W W
2D/1V
W
AP
2D/1V
W
2D/1V
2D/1V
2D/1V 2D/1V
W
W W
2D/1V 2D/1V
W
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D /1
V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
W
AP
AP
2D/1V
2D/1V
2D/1V
W
AP
AP
W
W
W
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
T
IDU-2
TR
1A109
3/8"ø RSP UP & DN 1/2"ø RRP UP & DN
1/2"ø RCD UP & DN
3/8"ø RSP UP & DN 1/2"ø RRP UP & DN 1/2"ø RCD UP & DN
1/2"ø RCD DN 3/8"ø RSP DN
1/2"ø RRP DN
EA
35 CFM
SA
35 CFM
Visitor Lounge
1A104
Physician Assistant
1A108
Corridor
1AC1
Corridor
1BC1
Corridor
1CC1
Nurse Manager
1C101
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:5
A
M
035-MH101
MECHANICAL NEW WORK PLAN -
FIRST FLOOR
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 035
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 35 - FIRST FLOOR - MECHANICAL NEW WORK PLAN
D R A W I N G N O T E S :
1 PROVIDE NEW SPLIT UNIT SYSTEM, ASSOCIATED PIPING, CONTROLS, SUPPORTS AND WIRING.
2 DRILL HOLES IN THE WALL TO RUN REFRIGERANT AND CONDENSATE DRAINAGE PIPING TO THE HEAT PUMP OUTSIDE.
3 RE BALANCE EXISTING VAV BOXES AND EXISTING RETURN GRILLES TO NEW AIRFLOW SHOW ON DRAWING.
No. Revisions: Date:
R E
F
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
W
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
46" MH
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
46" MH
2D/1V 46" MH
2D/1V
46" MH
2D/1V
2D/1V
2D/1V
2D/1V
46" MH
2D/1V
46" MH
2D/1V
46" MH
2D/1V
46" MH
2D/1V
AP
AP
T
IDU-2
TR
2A109
3/8"ø RSP UP & DN
1/2"ø RRP UP & DN
1/2"ø RCD UP & DN 3/8"ø RSP DN
1/2"ø RRP DN
1/2"ø RCD DN
EA
35 CFM
SA
35 CFM
Corridor
2AC1
Corridor
2BC1
Corridor
2CC1
Visitation Room
2C101
Nursing/ Break
2A104
Vistation Room
2B101
Fire Alarm Closet
2A106
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:5
A
M
035-MH102
MECHANICAL NEW WORK PLAN -
SECOND FLOOR
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 035
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 35 - SECOND FLOOR - MECHANICAL NEW WORK PLAN
D R A W I N G N O T E S :
1 PROVIDE NEW SPLIT UNIT SYSTEM, ASSOCIATED PIPING, CONTROLS, SUPPORTS AND WIRING.
2 DRILL HOLES IN THE WALL TO RUN REFRIGERANT AND CONDENSATE DRAINAGE PIPING TO THE HEAT PUMP OUTSIDE.
3 RE BALANCE EXISTING VAV BOXES AND EXISTING RETURN GRILLES TO NEW AIRFLOW SHOW ON DRAWING.
No. Revisions: Date:
46" MH
2D/1V 46" MH
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V2D/1V
2D/1V2D/1V 2D/1V
2D/1V
AP
AP
AP
2D/1V 2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
AP
2D /1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
AP
AP
W
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
AP
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
46" MH
2D/1V
2D/1V
2D/1V
AP
AP
46" MH
2D/1V
2D/1V
AP
46" MH
2D/1V
46" MH
2D/1V
2D/1V
2D/1V 46
M H
2D /1
V
2D/1V
W
2D/1V
2D/1V
2D/1V
AP
W
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
AP
APW
W
2D/1V
46" MH
2D/1V
46" MH
2D/1V
AP
AP
AP
2D/1V
2D/1V 2D/1V
2D/1V
AP
2D/1V
2D/1V
AP
W
T
TR
3A109
IDU-2
1/2"ø RCD DN
1/2"ø RRP DN
3/8"ø RSP DN
EA
35 CFM
SA
35 CFM
Physician Assistant
3A108
Health Behavior Coordinator
3A104
NCCPAC Revenue Utilization Review Nurse
3B101
Corridor
3BC1
Corridor
3AC1
Corridor
3CC1
Social Worker
3C101
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:0
A
M
035-MH103
MECHANICAL NEW WORK PLAN -
THIRD FLOOR
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 035
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 35 - THIRD FLOOR - MECHANICAL NEW WORK PLAN
D R A W I N G N O T E S :
1 PROVIDE NEW SPLIT UNIT SYSTEM, ASSOCIATED PIPING, CONTROLS, SUPPORTS AND WIRING.
2 DRILL HOLES IN THE WALL TO RUN REFRIGERANT AND CONDENSATE DRAINAGE PIPING TO THE HEAT PUMP OUTSIDE.
3 RE BALANCE EXISTING VAV BOXES AND EXISTING RETURN GRILLES TO NEW AIRFLOW SHOW ON DRAWING.
No. Revisions: Date:
G023 1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:4
A
M
210-MD100
MECHANICAL DEMOLITION PLAN -
BASEMENT
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 210
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 210 - BASEMENT - MECHANICAL DEMOLITION PLAN
D R A W I N G N O T E S :
1 EXISTING EQUIPMENT TO REMAIN.
No. Revisions: Date:
Equipment Storage
102 Staff Toilet
103A
Corridor
Activity/ Multi-Purpose Room
Beauty/Barber Shop
Elect. Room
Work Room
141A
Stair 4
100D
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:5
A
M
210-MD101
MECHANICAL DEMOLITION PLAN -
FIRST FLOOR
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 210
CHILLICOTHE
VAMC
Approved: Owner
D R A W I N G N O T E S :
1 REMOVE EXISTING RETURN GRILLE TO BE REINSTALLED LATER.
3/32" = 1'-0"
BLDG 210 - FIRST FLOOR - MECHNANICAL DEMOLITION PLAN
No. Revisions: Date:
BID DOCUMENTS 05/01/2023
Equipment Storage
Activity/ Multi-Purpose Room
Corridor
Beauty/Barber Shop
Clean Utility
238Work Room
241A
ELECT. ROOM
Nurses' Station
Food Cart
201A
Staff Toilet
203A
Stair 4
200D
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:0
A
M
210-MD102
MECHANICAL DEMOLITION PLAN -
SECOND FLOOR
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 210
CHILLICOTHE
VAMC
Approved: Owner
D R A W I N G N O T E S :
1 REMOVE EXISTING RETURN GRILLE TO BE REINSTALLED LATER.
3/32" = 1'-0"
BLDG 210 - SECOND FLOOR - MECHANICAL DEMOLITION PLAN
No. Revisions: Date:
S C
S C
S C
S C
2D/1V
2D/1V
2D/1V 2D /1
V
2D /1
V
AP
AP
2D/1V
2D/1V
AP
AP
2D/1V
2D /1
V
2D/1V
2D/1V
AP
1D
AP
AP
AP
AP
AP
1D
2D/1V
APAP
AP
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
AP
AP
AP
AP
AP
AP
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
AP
AP
46" MH2D/1V
2D/1V
2D/1V 2D/1V 2D/1V
2D/1V
2D/1V
AP AP
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
AP
AP
AP
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V2D/1V
2D/1V2D/1V
AP
AP
AP
T
TR
G023
ODU-1
1IDU-1
ODU-1
2 ODU-2
1/2"ø RCD UP
1/2"ø RRP UP
3/8"ø RSP UP 1/2"ø RCD UP 1/2"ø RRP UP 3/8"ø RSP UP
1/2"ø RCD 1/2"ø RRP 3/8"ø RSP
1/2"ø RCD 1/2"ø RRP 3/8"ø RSP
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:1
A
M
210-MH100
MECHANICAL NEW WORK PLAN -
BASEMENT
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 210
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 210 - BASEMENT - MECHANICAL NEW WORK PLAN
D R A W I N G N O T E S :
1 PROVIDE NEW SPLIT UNIT SYSTEM, ASSOCIATED PIPING, CONTROLS, SUPPORTS AND WIRING.
2 INSTALL NEW HEAT PUMP ON A CONCRETE PAD AND SUPPLY PIPING BACK TO TELECOMMUNICATION ROOM.
3 DRILL HOLES IN THE WALL TO RUN REFRIGERANT AND CONDENSATE DRAINAGE PIPING TO THE HEAT PUMP OUTSIDE.
No. Revisions: Date:
1D
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V 2D/1V
AP
AP
AP
AP
AP
AP
2D/1V
2D/1V
AP
AP
AP
AP
AP
W
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D/1V2D/1V
AP
AP
AP
AP
2D/1V2D/1V
2D/1V2D/1V2D/1V2D/1V
2D/1V2D/1V2D/1V2D/1V
AP
AP
2D/1V
2D/1V2D/1V2D/1V
2D/1V
2D /1
V
2D/1V
AP
AP
AP
AP
AP
2D/1V
AP
AP
2D/1V
2D/1V W W
AP
AP AP
AP
AP
AP
AP
AP
AP
AP
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
M H
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
1V
T
IDU-1
IDU-1
1/2"ø RCD UP & DN 1/2"ø RRP UP & DN
1/2"ø RCD UP & DN 3/8"ø RSP UP & DN
1/2"ø RRP UP & DN
3/8"ø RSP UP & DN
1/2"ø RCD 1/2"ø RRP
3/8"ø RSP 1/2"ø RCD 1/2"ø RRP 3/8"ø RSP
RA
120 CFM
SA
120 CFM
TR
102A
Equipment Storage
Corridor
Activity/ Multi-Purpose Room
103Closet
103B
Staff Toilet
103A
Beauty/Barber Shop
Elect. Room
Work Room
141A
Nurses' Station
Stair 4
100D
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:2
A
M
210-MH101
MECHANICAL NEW WORK PLAN -
FIRST FLOOR
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 210
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 210 - FIRST FLOOR - MECHANICAL NEW WORK PLAN
D R A W I N G N O T E S :
1 PROVIDE NEW SPLIT UNIT SYSTEM, ASSOCIATED PIPING, CONTROLS, SUPPORTS AND WIRING.
2 DRILL HOLES IN THE WALL TO RUN REFRIGERANT AND CONDENSATE DRAINAGE PIPING TO THE HEAT PUMP OUTSIDE.
3 PROVIDE NEW THERMOSTAT FOR TELECOMMUNICATION ROOM.
4 PROVIDE NEW DRIP PANS UNDER PIPING DIRECTLY OVER NEW ELECTRICAL EQUIPMENT.
5 REINSTALL RETURN GRILLE TO MAIN ON THE OUTSIDE OF THE WALL.
No. Revisions: Date:
2D/1V
2D/1V
2D/1V
W
W
AP
APAP
AP AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
1D
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
AP
AP
AP
AP
AP
AP
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V2D/1V
AP
AP
AP
2D/1V2D/1V2D/1V2D/1V
2D/1V2D/1V2D/1V2D/1V
2D/1V2D/1V2D/1V2D/1V
2D/1V
2D/1V
2D/1V
AP
AP
AP AP
AP
AP
AP
AP
AP
AP
1D 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
AP
AP
AP
AP
AP
2D/1V
T
1IDU-1
3/8"ø RSP 1/2"ø RRP
1/2"ø RCD
3/8"ø RSP 1/2"ø RRP 1/2"ø RCD
RA
120 CFM
SA
120 CFM
Equipment Storage
TR
202A
Food Cart
201A
Corridor
Beauty/Barber Shop
ELECT. ROOM
Work Room
241A
Nurses' Station
Activity/ Multi-Purpose Room
Staff Toilet
203A
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:3
A
M
210-MH102
MECHANICAL NEW WORK PLAN -
SECOND FLOOR
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 210
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 210 - SECOND FLOOR - MECHANICAL NEW WORK PLAN
D R A W I N G N O T E S :
1 PROVIDE NEW SPLIT UNIT SYSTEM, ASSOCIATED PIPING, CONTROLS, SUPPORTS AND WIRING.
2 DRILL HOLES IN THE WALL TO RUN REFRIGERANT AND CONDENSATE DRAINAGE PIPING TO THE HEAT PUMP OUTSIDE.
3 PROVIDE NEW THERMOSTAT FOR TELECOMMUNICATION ROOM.
4 PROVIDE NEW DRIP PANS UNDER PIPING DIRECTLY OVER NEW ELECTRICAL EQUIPMENT.
5 RE BALANCE EXISTING VAV BOXES AND EXISTING RETURN GRILLES TO NEW AIRFLOW SHOW ON DRAWING.
No. Revisions: Date:
Corridor
G001
TR
G020
Bistro
G019
Toilet
G014
Toilet
G015 Linen Chute Collect.
G018
Mechanical
G028
Staff Locker
G027
Mop Closet
G027B
Tele Clos
G007
Office
G006A Toilet
G005
Toilet
G004
Clean Linen
G003
Waiting
G008A
Stair
S6-G Space
3CC7
Corridor
G001
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:2
A
M
211-MD100
MECHANICAL DEMOLITION PLAN -
BASEMENT
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 211
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 211 - BASEMENT - MECHANICAL DEMOLITION PLAN
D R A W I N G N O T E S :
1 DEMOLISH EXISTING SPLIT UNIT SYSTEM, ASSOCIATED PIPING, CONTROLS, SUPPORTS AND WIRING.
2 REMOVE EXISTING RETURN GRILLE TO BE REINSTALLED LATER.
No. Revisions: Date:
Dining Room
Soiled Utility
Waiting
111A
Corridor
Corridor
Living Room
Food Service
Dining Room
Kitchen
Stair
S2-1 Toilet
Staff Toilet
Corridor
Activities
Clean Utility
Elect. Room
Beauty / Barber Shop
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:4
A
M
211-MD101
MECHANICAL DEMOLITION PLAN -
FIRST FLOOR
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 211
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 211 - FIRST FLOOR - MECHANICAL DEMOLITION PLAN
D R A W I N G N O T E S :
1 REMOVE EXISTING SUPPLY DIFFUSER TO BE REINSTALLED LATER.
No. Revisions: Date:
Dining Room
Soiled Utility
Waiting
211A
Corridor
Activities
Clean Utility
Elect. Room
261Beauty / Barber Shop
Corridor
Food Service
207 Living Room
Dining Room
Stair
S2-2Toilet
Staff Toilet
Kitchen
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:5
A
M
211-MD102
MECHANICAL DEMOLITION PLAN -
SECOND FLOOR
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 211
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 211 - SECOND FLOOR - MECHANICAL DEMOLITION PLAN
D R A W I N G N O T E S :
1 REMOVE EXISTING SUPPLY DIFFUSER TO BE REINSTALLED LATER.
No. Revisions: Date:
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
1V 1V
1V 1V
1V 1V
1V 1V
1V 1V
2D/1V
2D/1V
2D/1V2D/1V 2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
1D
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
W W
2D/1V
2D/1V
W
46" MH2D/1V
46" MH
2D/1V
46" MH
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V 2D/1V
2D/1V
2D/1V2D/1V
2D/1V
W
1D
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V 2D/1V
2D/1V 2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
1V
T
1ODU-2
IDU-22
3/8"ø RSP 1/2"ø RRP 1/2"ø RCD
1/2"ø RRP UP
3/8"ø RSP UP 1/2"ø RRP UP
3/8"ø RSP UP1/2"ø RCD UP
ODU-2ODU-1ODU-1
3/8"ø RSP UP
1/2"ø RRP UP
1/2"ø RCD UP
3/8"ø RSP UP
1/2"ø RRP UP
1/2"ø RCD UP
3/8"ø RSP UP
1/2"ø RRP UP
1/2"ø RCD UP
Corridor
G001
Bistro
G019
Vestibule
G012
Elevator Equipment
G027A
Toilet
G014
Toilet
G015
TR
G020
Linen Chute Collect.
G018
Staff Locker
G027 Clean Linen
G003
Mechanical
G028
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:0
A
M
211-MH100
MECHANICAL NEW WORK PLAN -
BASEMENT
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 211
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 211 - BASEMENT - MECHANICAL NEW WORK PLAN
D R A W I N G N O T E S :
1 INSTALL NEW HEAT PUMP ON A CONCRETE PAD AND SUPPLY PIPING BACK TO TELECOMMUNICATION ROOM.
2 PROVIDE NEW SPLIT UNIT SYSTEM, ASSOCIATED PIPING, CONTROLS, SUPPORTS AND WIRING.
3 PROVIDE NEW THERMOSTAT FOR TELECOMMUNICATION ROOM.
4 REINSTALL RETURN GRILLE TO MAIN ON THE OUTSIDE OF THE WALL.
5 DRILL HOLES IN THE WALL TO RUN REFRIGERANT AND CONDENSATE DRAINAGE PIPING TO THE HEAT PUMP OUTSIDE.
No. Revisions: Date:
AP
AP
AP
AP
AP
AP
72" MH
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
APAP
AP
AP
2D/1V
70" MH
2D/1V
46" MH2D/1V
46" MH
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
W
W 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
W
W
W
2D/1V
2D / 1V2D/1V
2D/1V
2D/1V
46" MH
2D/1V
46" MH
2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D/1V
46" M H
2D / 1V
46" M H2D
/ 1V 46" M
H2D / 1V
2D/1V
2D/1V
46" MH
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V46" M H
2D / 1V
46" M H2D
/ 1V 46" M
H2D / 1V
2D/1V
2D/1V
2D/1V
W
2D/1V
T
T
TT
IDU-2 2
1/2"ø RCD DN 1/2"ø RCD UP & DN
1/2"ø RRP DN
3/8"ø RSP DN
1/2"ø RRP UP & DN
3/8"ø RSP UP & DN
3/8"ø RSP 1/2"ø RRP 1/2"ø RCD
3/8"ø RSP 1/2"ø RRP
1/2"ø RCD
2 IDU-1
IDU-1
3 3 1/2"ø RCD UP & DN
1/2"ø RRP UP & DN
3/8"ø RSP UP & DN
Food Service
TR
108A Living Room
Stair
S2-1
Corridor
Dining Room
Kitchen
Toilet
Staff Toilet
Corridor
Waiting
111A
Corridor
Soiled Utility
TR
198A
Dining Room
Activities
Clean Utility
Elect. Room
Central Work Station
Beauty / Barber Shop
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:1
A
M
211-MH101
MECHANICAL NEW WORK PLAN -
FIRST FLOOR
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 211
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 211 - FIRST FLOOR - MECHANICAL NEW WORK PLAN
D R A W I N G N O T E S :
1 PROVIDE NEW THERMOSTAT FOR TELECOMMUNICATION ROOM.
2 PROVIDE NEW SPLIT UNIT SYSTEM, ASSOCIATED PIPING, CONTROLS, SUPPORTS AND WIRING.
3 DRILL HOLES IN THE WALL TO RUN REFRIGERANT AND CONDENSATE DRAINAGE PIPING TO THE HEAT PUMP OUTSIDE.
4 REROUTE EXISTING FIRE PROTECTION PIPING.
No. Revisions: Date:
1V
2D/1V
2D/1V
2D/1V
W
W
AP
AP
AP
AP AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
1V
2D/1V
1V
1V
2D/1V 2D/1V
2D/1V
2D/1V2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
AP
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
1V
1V
1V
T
TT
2IDU-2
1/2"ø RCD DN 3/8"ø RSP DN
1/2"ø RRP DN
1/2"ø RCD
1/2"ø RRP 3/8"ø RSP
2 IDU-2
Corridor
Dining Room
Waiting
211A
Soiled Utility
TR
298A
Activities
Beauty / Barber Shop
Clean Utility
Elect. Room
Central Work Station
Food Service
Kitchen
Dining Room
Living Room
Room
208B
Corridor
Stair
S2-2
Corridor
Staff Toilet
Toilet
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:2
A
M
211-MH102
MECHANICAL NEW WORK PLAN -
SECOND FLOOR
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 211
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 211 - SECOND FLOOR - MECHANICAL NEW WORK PLAN
D R A W I N G N O T E S :
1 PROVIDE NEW THERMOSTAT FOR TELECOMMUNICATION ROOM.
2 PROVIDE NEW SPLIT UNIT SYSTEM, ASSOCIATED PIPING, CONTROLS, SUPPORTS AND WIRING.
3 DRILL HOLES IN THE WALL TO RUN REFRIGERANT AND CONDENSATE DRAINAGE PIPING TO THE HEAT PUMP OUTSIDE.
4 REINSTALL SUPPLY DIFFUSER OUTSIDE OF THE WALL.
No. Revisions: Date:
Elevator Lobby
Stair #2
S2-0 Privacy Officer
Storage
15B
Elevator Equipment
Corridor
C1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:5
A
M
212-MD100
MECHANICAL DEMOLITION PLAN -
BASEMENT
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 212
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 212 - BASEMENT - MECHANICAL DEMOLITION PLAN
D R A W I N G N O T E S :
1 DEMOLISH EXISTING SPLIT UNIT SYSTEM, ASSOCIATED PIPING, CONTROLS, SUPPORTS AND WIRING.
2 DEMOLISH EXISTING WINDOW AC UNIT, CONNECTED WIRING, CONTROLS, AND SUPPORTS AND COORDINATE WINDOW
REPLACEMENT WITH GENERAL CONTRACTOR.
No. Revisions: Date:
REF.
DN1
DATA
Corridor
C101
Storage
Stair #3
S3-1
Daycare Storage
139B
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:5
A
M
212-MD101
MECHANICAL DEMOLITION PLAN -
FIRST FLOOR
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 212
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 212 - FIRST FLOOR - MECHANICAL DEMOLITION PLAN
D R A W I N G N O T E S :
1 DEMOLISH EXISTING SPLIT UNIT SYSTEM, ASSOCIATED PIPING, CONTROLS, SUPPORTS AND WIRING.
No. Revisions: Date:
COPIER
224A
PATIENT BUSINESS SERVICE
CHIEF
Corridor
C202
STAIRS
S2-2
Corridor
C203
PATIENT BUSINESS SERVICE
SECRETARY
240A
PATIENT BUSINESS SERVICE
ASSISTANT CHEIF
UNOCCUPIED OFFICE SPACE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:0
A
M
212-MD102
MECHANICAL DEMOLITION PLAN -
SECOND FLOOR
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 212
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 212 - SECOND FLOOR - MECHANICAL DEMOLITION PLAN
D R A W I N G N O T E S :
1 DEMOLISH EXISTING SPLIT UNIT SYSTEM, ASSOCIATED PIPING, CONTROLS, SUPPORTS AND WIRING.
No. Revisions: Date:
AP
AP
AP
AP
AP
2D/1V 2D/1V
2D/1V
W
AP
2D/1V
2D/1V
AP 2D/1V
2D/1V
AP
AP
AP
AP
AP
AP AP
AP
AP
AP
2D/1V 2D/1V 2D/1V 2D/1V 2D/1V
2D/1V2D/1V2D/1V
2D/1V
W
AP
2D/1V
2D/1V W
2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D/1V
2D/1V
T
ODU-2
IDU-2
TR
15A
ODU-2
3/8"ø RSP 1/2"ø RRP 1/2"ø RCD
3/8"ø RSP UP
1/2"ø RRP UP 1/2"ø RCD UP
2ODU-2
1/2"ø RRP UP
3/8"ø RSP UP
1/2"ø RCD UP
Elevator Equipment
Elevator Lobby
Stair #2
S2-0
Storage
15B
TR
15A
Privacy Officer
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:0
A
M
212-MH100
MECHANICAL NEW WORK PLAN -
BASEMENT
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 212
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 212 - BASEMENT - MECHANICAL NEW WORK PLAN
D R A W I N G N O T E S :
1 PROVIDE NEW SPLIT UNIT SYSTEM, ASSOCIATED PIPING, CONTROLS, SUPPORTS AND WIRING.
2 INSTALL NEW HEAT PUMP ON A CONCRETE PAD AND SUPPLY PIPING BACK TO TELECOMMUNICATION ROOM.
3 DRILL HOLES IN THE WALL TO RUN REFRIGERANT AND CONDENSATE DRAINAGE PIPING TO THE HEAT PUMP OUTSIDE.
4 PROVIDE NEW THERMOSTAT FOR TELECOMMUNICATION ROOM.
No. Revisions: Date:
REF.
AP
AP
AP
2D/1V 2D/1V 2D/1V
2D/1V
2D/1V
2D/1V 2D/1V2D/1V
1D
1D
2D/1V
2D/1V
AP
AP AP
3D 3D
2D/1V
2D/1V2D/1V
1D
2D/1V 1D
2D/1V
AP
2D/1V
2D/1V 2D/1V
2D/1V
AP
2D/1V
AP
AP
1D
AP
AP
2D/1V2D/1V
2D/1V
AP
6D
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
AP
AP
W
AP
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V2D/1V
W
2D/1V 2D/1V
2D/1V
2D/1V2D/1V
2D/1V2D/1V 2D/1V
APAP
2D/1V2D/1V
AP
2D/1V
2D/1V
2D/1V
2D/1V
AP
2D/1V2D/1V
2D/1V2D/1V
T
AFGE Storage
114A
DATA
IDU-2
33/8"ø RSP DN
1/2"ø RRP DN
1/2"ø RCD DN
3/8"ø RSP UP & DN
1/2"ø RRP UP & DN
1/2"ø RCD UP & DN
TR
Vacant Nurse Station
Vacant Med Room
149A Storage
Vacant
Stair #2
S2-1
Elevator Lobby
Corridor
C101
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:1
A
M
212-MH101
MECHANICAL NEW WORK PLAN -
FIRST FLOOR
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 212
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 212 - FIRST FLOOR - MECHANICAL NEW WORK PLAN
D R A W I N G N O T E S :
1 PROVIDE NEW THERMOSTAT FOR TELECOMMUNICATION ROOM.
2 PROVIDE NEW SPLIT UNIT SYSTEM, ASSOCIATED PIPING, CONTROLS, SUPPORTS AND WIRING.
3 DRILL HOLES IN THE WALL TO RUN REFRIGERANT AND CONDENSATE DRAINAGE PIPING TO THE HEAT PUMP OUTSIDE.
No. Revisions: Date:
AP AP
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
AP
2D/1V
2D/1V2D/1V 2D/1V
2D/1V
2D/1V 2D/1V
AP
2D/1V
2D/1V 2D/1V
2D/1V
AP
AP AP
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V 2D/1V
2D/1V
AP
AP
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V2D/1V
2D/1V 2D/1V
2D/1V
2D2D2D
2D2D2D
2D2D2D
2D2D2D
2D2D2D
AP AP
2D/1V 2D/1V
2D/1V2D/1V
2D/1V 2D/1V
2D/1V
2D2D2D
2D2D2D
2D2D2D
2D2D2D
2D2D2D
AP AP
AP
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
AP
AP AP
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D 2D 2D2D 2D
2D 2D 2D2D
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
AP
AP
T
TR
IDU-2
3/8"ø RSP DN
1/2"ø RRP DN
1/2"ø RCD DN
PATIENT BUSINESS SERVICE
SECRETARY
240A
PATIENT BUSINESS SERVICE
ASSISTANT CHEIF
UNOCCUPIED OFFICE SPACE
Corridor
C203
Corridor
C202
STAIRS
S2-2COPIER
224A
PATIENT BUSINESS SERVICE
CHIEF
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:2
A
M
212-MH102
MECHANICAL NEW WORK PLAN -
SECOND FLOOR
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 212
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 212 - SECOND FLOOR - MECHANICAL NEW WORK PLAN
D R A W I N G N O T E S :
1 PROVIDE NEW SPLIT UNIT SYSTEM, ASSOCIATED PIPING, CONTROLS, SUPPORTS AND WIRING.
2 DRILL HOLES IN THE WALL TO RUN REFRIGERANT AND CONDENSATE DRAINAGE PIPING TO THE HEAT PUMP OUTSIDE.
3 PROVIDE NEW THERMOSTAT FOR TELECOMMUNICATION ROOM.
No. Revisions: Date:
2D/1V2D/1V
2D/1V
AP
2D/1V
2D/1V
46" MH2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
AP
AP
T
46" MH2D/1V 2D/1V
2D/1V
TR
2-9
Office
2-3
Space
2-2
Office
2-1
Corridor
C-1 3 IDU-2
3/8"ø RSP
1/2"ø RRP
1/2"ø RCD
1 ODU-2
3/8"ø RSP UP 1/2"ø RRP UP
1/2"ø RCD UP
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:4
A
M
259-MH101
MECHANICAL NEW WORK PLAN -
SECOND FLOOR
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 259
CHILLICOTHE
VAMC
Approved: Owner
3/32" = 1'-0"
BLDG 259 - SECOND FLOOR - MECHANICAL NEW WORK PLAN
D R A W I N G N O T E S :
1 INSTALL NEW HEAT PUMP ON A CONCRETE PAD AND SUPPLY PIPING BACK TO TELECOMMUNICATION ROOM.
2 PROVIDE NEW THERMOSTAT FOR TELECOMMUNICATION ROOM.
3 PROVIDE NEW SPLIT UNIT SYSTEM, ASSOCIATED PIPING, CONTROLS, SUPPORTS AND WIRING.
4 DRILL HOLES IN THE WALL TO RUN REFRIGERANT AND CONDENSATE DRAINAGE PIPING TO THE HEAT PUMP OUTSIDE.
3/32" = 1'-0"
BLDG 259 - FIRST FLOOR - MECHANICAL NEW WORK PLAN
No. Revisions: Date:
DNUP
A P
2 2 2D
/1V
2D /1V
A P
2V
1V 1D
/1V
T
1/2"ø RCD 1/2"ø RRP 3/8"ø RSP
IDU-2
ODU-2
Control Room
Corridor
Office
Toilet
Storage
HAC
Break Room
TR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:5
A
M
261-MH101
MECHANICAL NEW WORK PLAN -
FIRST FLOOR
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTS 261
CHILLICOTHE
VAMC
Approved: Owner
D R A W I N G N O T E S :
1 PROVIDE NEW SPLIT UNIT SYSTEM, ASSOCIATED PIPING, CONTROLS, SUPPORTS AND WIRING.
2 INSTALL NEW HEAT PUMP ON A CONCRETE PAD AND SUPPLY PIPING BACK TO TELECOMMUNICATION ROOM.
3 DRILL HOLES IN THE WALL TO RUN REFRIGERANT AND CONDENSATE DRAINAGE PIPING TO THE HEAT PUMP OUTSIDE.
4 PROVIDE NEW THERMOSTAT FOR TELECOMMUNICATION ROOM.
3/32" = 1'-0"
BLDG 261 - FIRST FLOOR - MECHANICAL NEW WORK PLAN
No. Revisions: Date:
REFRIGERANT SUPPLY AND RETURN
LINES MOVING HEAT FROM THE
INDOOR UNIT TO THE HEAT PUMP.
DRAIN PIPING
HOT RETURN AIR FROM TR
COOL SUPPLY AIR FROM
THE SPLIT UNIT INTO TR
AIR FILTER
LOUVER
INDOOR UNIT
(FAN UNIT)
OUTDOOR UNIT
(HEAT PUMP)
FUNCTION SWITCH
AIR OUTLET GRILLE
COOL OA THROUGH
BACK OF HEAT PUMP
WARM OA EXHAUSTED OUT
THE FRONT OF THE HEAT PUMP
4' - 0"
4' - 0"
HEAT PUMP
CONCRETE PAD
GROUND
H E
A T
P U
M P
CONCRETE PAD
GROUND
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:0
A
M
M500
MECHANICAL DETAILS
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTSCHILLICOTHE
VAMC
Approved: Owner
NTS
Mini-Split Sytem Detail
NTS
Concrete Pad for Heat Pump
No. Revisions: Date:
NEW TR
SPACE
T
HVAC
MS
SPLIT SYSTEM DRAIN PAN
(TYP)
POINT TYPE ALARMS
POINT DESCRIPTION
G R
A P
H
IC
H A
R D
W A
R E
IN
P U
T
H A
R D
W A
R E
O U
T P
U T
S O
F T
W A
R E
P O
IN
T
D E
F A
U L
T V
A L
U E
H
IG
H A
N A
L O
G L
IM
IT
L O
W A
N A
L O
G L
IM
IT
B
IN
A R
Y
L A
T C
H D
IA
G
N O
S T
IC
S E
N S
O R
F A
IL
C O
M M
U N
IC
A
T
IO
N F
A
IL
D
IA
G N
O S
T
IC
S
NOTES
EMCS UNITARY AIR CONDITIONING UNITS - ALARM
MONITORING
ZONE SENSOR
ZONE TEMPERATURE X AI X X X SENSOR FAILURE 1
X BI X X SENSOR FAILURE 1
BAS COMMUNICATION STATE X X X
KEY: A = ANALOG, B = BINARY, I = INPUT, O = OUTPUT
NOTES: 1. SENSOR FOR MONITORING AND ALARMS.
POINT TYPE ALARMS
POINT DESCRIPTION
DRAIN PAN MOISTURE
CONTROLS SYMBOLS
T TEMPERATURE TRANSMITTER - WALL MOUNT
HVAC DDC CONTROLLER
CONTROL SIGNAL
MS MOISTURE SWITCH - SECONDARY DRAIN PAN
CONTROLS FOR UNITARY EQUIPMENT SERVING THE TR ROOMS ARE
STAND-ALONE TYPE. CONTRACTOR SHALL PROVIDE PROGRAMMABLE
THERMOSTAT/REMOTE CONTROLLER REQUIRED TO CONTROL TO THE
SETPOINTS AND SCHEDULES LISTED BELOW.
THE CONTROL DIAGRAM AND POINTS LIST ON THIS SHEET SHOWS
SENSORS USED FOR CENTRAL MONITORING AND ALARMS. SENSORS
AND POINTS ARE IN ADDITION TO THE CONTROLS REQUIRED FOR THE
OPERATION OF THE UNITARY CONDITIONING EQUIPMENT AND
HUMIDIFIER.
EQUIPMENT SETPOINTS:
COOLING (ACU-1): 78 F
ANALOG ALARM SETPOINTS:
TEMPERATURE LOW: 62F
TEMPERATURE HIGH: 83F
CONTROLS OVERVIEW - TR ROOM HVAC
SPLIT SYSTEM HEAT PUMP SCHEDULE
MARK LOCATION
AREA
AND/OR
BLDG
SERVED
TYPE
TOTAL SUPPLY
AIR FLOW
MIN. OUTSIDE
AIR FLOW
EXT STATIC
PRESSURE
COOLING CAPACITY HEATING CAPACITY
AIR FILTER
MARK NO
ELECTRICAL DATA
REMARKSMIN TOTAL
CAPACITY
MIN SENS
CAPACITY MIN
SEER
EAT OSA DESIGN
TEMP COMP
RLA/FLA
MIN. HEAT
CAPACITY
EAT DB
LAT
Db
OSA DESIGN
TEMP
INDOOR FAN OUTDOOR UNIT FAN MCA
(OUTDOOR/
INDOOR UNIT)
PHASE VOLTDb Wb
CFM [L/s] CFM [L/s] IN [Pa] MBH [kW] MBH [kW] °F [°C] °F [°C] °F [°C] MBH KW °F [°C] °F [°C] °F [°C] HP [W] CONTROL CURRENT [A] CONTROL
ODU-1 / IDU-1 CAMPUS IT CLOSETS
DUCTLESS
HEAT PUMP
117-437 [55-210] 0 [ 0 ] N/A N/A 12 [ 41 ] 11.04 [ 3 ] 21.5 81 [ 27 ] 67 [ 19 ] [ 95 ] [ 35 ] 5.7/0.42 12 [ 4 ] 60 [ 16 ] 80 [ 27 ] [ 47 ] [ 8 ]
N/A - INTEGRAL
TO IDU-1
0.67 [ 500 ]
AUTO SPEED
ADJ.
0.42 ADJUSTABLE 15 / 1 1 208 -----
ODU-2 / IDU-2 CAMPUS IT CLOSETS
DUCTLESS
HEAT PUMP
117-437 [55-210] 0 [ 0 ] N/A N/A 18 [ 61 ] 16.56 [ 5 ] 19.5 81 [ 27 ] 67 [ 19 ] [ 95 ] [ 35 ] 7.3/0.95 18 [ 5 ] 60 [ 16 ] 80 [ 27 ] [ 47 ] [ 8 ]
N/A - INTEGRAL
TO IDU-2
0.67 [ 500 ]
AUTO SPEED
ADJ.
0.95 ADJUSTABLE 13 / 1 1 208 -----
NOTES:
1. PROVIDE PRECHARGED REFRIGERANT LINE SET BETWEEN INDOOR UNIT AND OUTDOOR UNIT.
2. PROVIDE WALL MOUNTED REMOTE CONTROLLER.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:5
:1
A
M
M601
MECHANICAL SCHEDULES AND
CONTROLS
05/01/2023 KF JV
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
95% CONSTRUCTION
DOCUMENTSCHILLICOTHE
VAMC
Approved: Owner
No. Revisions: Date:
KEY PAD/CARD READER
PANIC BUTTON
HANDICAP DOOR MOTOR
HANDICAP DOOR OPERATOR
ELECTRIC LATCH
SECURITY CAMERA CCTV - DOME
DURESS/PANIC ALARM
PILOT LIGHT / CHIME
PUSHBUTTON
MD MOTION DETECTOR
CC
EL
AP
X
PB
K
HD
HA
PP
WIRELESS ACCESS POINT
KEY PAD
FIRE ALARM CONTROL PANEL
FIRE ALARM ANNUNCIATOR PANEL
FIRE ALARM STROBE
FIRE ALARM STROBE
FIRE ALARM SPEAKER/STROBE
FIRE ALARM CHIME/STROBE
FIRE ALARM SPEAKER/STROBE CEILDING MOUNTED
SMOKE DETECTOR
DUCT DETECTOR. "R" INDICATES RETURN DUCT. "S"
INDICATES SUPPLY DUCT.
DUCT REMOTE TEST STATION
KNOX BOX
FIRE ALARM CONTROL RELAY. C- CONTROL I-INPUT.
DOOR HOLDER
HEAT DETECTOR
COMBINATION HORN/STROBE WITH SENDING STATION
FACP
FAA
F
F
F
S
F F
S
H
S
R
K
AM
D
R
C
FIRE ALARM
DATA/TELEPHONE
SECURITY / ACCESS CONTROL
LIGHTING
POWER
GROUNDING
EMERGENCY LIGHT
EXTERIOR SITE
WIRING ABBREVIATIONS
DATA/TELEPHONE OUTLET. PROVIDE (2) CAT 6a CABLES WITHIN
CONDUIT OR OTHER APPROVED RACEWAY FROM OUTLET TO
NEAREST IT CLOSET OR CABLE TRAY. SUBSCRIPT INDICATES # OF
DATA CABLES.
1' x 4' FIXTURE. UPPERCASE INDICATES TYPE PER THE FIXTURE SCHEDULE.
LOWER CASE LETTER "a" INDICATES SWITCH ZONE.
2' x 4' FIXTURE.
WALL MOUNTED FIXTURE.
INDUSTRIAL FIXTURE.
WALL MOUNTED FIXTURE.
EXIT SIGN WITH DIRECTIONAL ARROWS AS INDICATED
RECESSED FIXTURE, DOWNLIGHT
3-WAY, 20 AMP, 125 VOLT TOGGLE SWITCH MOUNTED 42" AFF.
4-WAY, 20 AMP, 125 VOLT TOGGLE SWITCH MOUNTED 42" AFF.
WALL MOUNTED OCCUPANCY SENSOR WITH OVERRIDE SWITCH
CEILING MOUNTED OCCUPANCY SENSOR
20 AMP, 125 VOLT SINGLE-POLE TOGGLE SWITCH MOUNTED 42" AFF.
a - CONTROLS LIGHTS WITH "a" DESIGNATION
LIGHTING CONTROLLER
20A, 125V DIMMER SWITCH MOUNTED 42" AFF
2' x 2' FIXTURE.
CEILING MOUNTED DAYLIGHT SENSOR
PHOTOCELL
A1 a a
OS
D
OS
DS
LC#
PC
FLUSH FLOOR MOUNTED NEMA 5-20 DUPLEX RECEPTACLE
UNLESS NOTED OTHERWISE
FLUSH FLOOR MOUNTED NEMA 5-20 QUAD RECEPTACLE
UNLESS NOTED OTHERWISE
NEMA 5-20 DUPLEX RECEPTACLE MOUNTED 18" AFF
UNLESS NOTED OTHERWISE
SUBSCRIPT: WP - WEATHERPROOF, GF - GROUND FAULT CIRCUIT
INTERRUPTER
NEMA 5-20 DOUBLE DUPLEX RECEPTACLE MOUNTED 18" AFF
UNLESS NOTED OTHERWISE
NEMA 5-20 DUPLEX RECEPTACLE MOUNTED 44" AFF
UNLESS NOTED OTHERWISE
RECEPTACLE, (NEMA CONFIGURATION AS NOTED)
NEMA 5-20 DUPLEX RECEPTACLE WITH USB CHARGER MOUNTED 18" AFF
UNLESS NOTED OTHERWISE
NEMA 5-20 DUPLEX SPLIT RECEPTACLE MOUNTED 18" AFF
UNLESS NOTED OTHERWISE
NEMA 5-20 SIMPLEX RECEPTACLE MOUNTED 18" AFF
UNLESS NOTED OTHERWISE
JUNCTION BOX
POWER CONNECTION
MOTOR
NON-FUSED DISCONNECT SWITCH. SIZE AS SHOWN
FUSED DISCONNECT SWITCH. SIZE FUSES FOR EQUIPMENT
BASED ON MANUFACTURERS RECOMMENDATIONS
COMBINATION STARTER
SURFACE MOUNTED PANELBOARD OR AUTOMATIC TRANSFER
SWITCH AS INDICATED.
RECESSED MOUNTED PANELBOARD
UNDERGROUND
CONCEALED OR OPEN
FLEXIBLE CONDUIT CONNECTION
EXISTING UNDERGROUND ELECTRICAL LINE.EUP
WP/GF
6-30R
J
EXISTING OVERHEAD ELECTRICAL LINE.
EXISTING UNDERGROUND COMMUNICATION LINE
EXISTING OVERHEAD COMMUNICATION LINE
EXISTING ITEMS TO BE REMOVED
NEW UNDERGROUND PRIMARY
NEW UNDERGROUND SECONDARY
NEW UNDERGROUND COMMUNICATIONS
EXISTING SECTIONALIZER CABINET
NEW PAD MOUNTED TRANSFORMER
NEW ELECTRICAL HANDHOLE
EXISTING COMMUNICATIONS MANHOLE
NEW COMMUNICATIONS MANHOLE
EXISTING POLE MOUNTED LIGHTING FIXTURE
NEW POLE MOUNTED LIGHTING FIXTURE
NEW BOLLARD LIGHT FIXTURE.
EP
EUC
EC
E
UP
US
UC
S
T
H
E
M
M
C
C
AIR TERMINAL
GROUNDING ROD
STATIC GROUNDING RECEPTACLE
CONNECTION TO GROUND
GRID COUNTERPOISE CONDUCTOR
LIGHTNING PROTECTION ROOF CONDUCTOR
LIGHTNING PROTECTION DOWN CONDUCTOR
G
RC
DC
2' x 4' FIXTURE. SOLID FILL INDICATES FIXTURE ON LIFE SAFETY OR
EMERGENCY CIRCUIT.
(WHERE GENERATOR POWER IS NOT AVAILABLE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .