Attachment 09 - SOW attach Volume 1 Part 4.pdf

PDF 9 MB Posted

Attached to
Y1DA--538-21-701 EHRM Infrastructure Upgrades Construction Chillicothe, OH (VA-23-00066755)
Solicitation number
36C77623B0058
Issued by

About this file

This document is a solicitation for construction services for infrastructure upgrades at the Chillicothe VA Medical Center in Chillicothe, Ohio. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center in Austin, Texas for project number 538-21-701. The scope of work includes renovations and upgrades to existing buildings including demolition, new partitions, flooring replacement, and electrical work. The estimated award date is April 2023. Pricing will be fixed-price.

View the file

Other files

File Type Posted
Abstract of offers - Chillicothe Bid Opening 01172024 signed.pdf PDF
S06 - Amendment 0009 Bid Opening.pdf PDF
S06 - Amendment 0008 Extend due date to 01172024.pdf PDF
S06 - 36C77623B0058 0007.pdf PDF
S06 - Amendment 0007 Att 10 - 14.063_024-EP100 - ELECTRICAL PLAN - BASEMENT FLOOR.pdf PDF
S06 - Amendment 0007 Att 13 - 14.116_E616.31 - PANELBOARD SCHEDULES.pdf PDF
S06 - Amendment 0007 Att 4 - Chiillicothe VA Lead Paint Survey Report.pdf PDF
S06 - Amendment 0007 Att 7 - 000-TS100 - CAMPUS TECHNOLOGY SITE PLAN.pdf PDF
S06 - Amendment 0007 Att 6 - 000-TN500 - TECHNOLOGY DETAILS.pdf PDF
S06 - Amendment 0007 Att 3 - 2023-01 AHERA.pdf PDF
S06 - Amendment 0007 Att 11 - 14.077_031-EP100 - ELECTRICAL PLAN - GROUND FLOOR.pdf PDF
S06 - Amendment 0007 Att 16 - 026-TN100 - BASEMENT PLAN -TECHNOLOGY.pdf PDF
S06 - Amendment 0007 Att 14 - 018-TN209 - TECHNOLOGY ENLARGEMENT.pdf PDF
S06 - Amendment 0007 Att 8 - 13.038_030-MD101 - MECHANICAL DEMOLITION PLAN - FIRST FLOOR.pdf PDF
S06 - Amendment 0007 Att 12 - 14.080_035-EP100 - ELECTRICAL PLAN - BASEMENT.pdf PDF
S06 - Amendment 0007 Att 1 Technical questions Round 2 responses.pdf PDF
S06 - Amendment 0007 Att 2 - Final SWP3.pdf PDF
S06 - Amendment 0007 Att 15 - 018-TN210 - TECHNOLOGY ENLARGEMENT.pdf PDF
S06 - Amendment 0007 Att 5 - 000-TN400 - TECHNOLOGY RISER DIAGRAMS.pdf PDF
S06 - Amendment 0007 Att 9 - 14.062_023-EP101 - ELECTRICAL PLAN - FIRST FLOOR.pdf PDF
Amendment 0006 36C77623B0058.pdf PDF
Amendment 0005 36C77623B0058.pdf PDF
Amendment 0005 - Attachment Addendum 1.zip ZIP file
Amendment 0005 - Attachment - Vendor Questions_Responses final.pdf PDF
Amendment 0004 36C77623B0058.pdf PDF
Amendment 0003 36C77623B0058.docx DOCX document
Att 10 Volume 10 - Technology_Combined.pdf PDF
Att 8 Volume 8 - Electrical_Combined.pdf PDF
Att 6 Volume 6 - Mechanical_Combined.pdf PDF
Att 9 Volume 9 - Electrical_Combined.pdf PDF
Att 13 Volume 13 - Fiber_Combined.pdf PDF
Att 4 Volume 4 - Architectural_Combined.pdf PDF
Att 5 Volume 5 - Fire Suppression_Combined.pdf PDF
Att 14 S04 - Site Visit sign in 10-11-2023.pdf PDF
Att 7 Volume 7 - Mechanical_Combined.pdf PDF
Att 12 Volume 12 - Fiber_Combined.pdf PDF
Att 11 Volume 11 - Technology_Combined.pdf PDF
Att 3 Volume 3 - Architectural_Combined.pdf PDF
Att 2 Volume 2 - Civil_Combined (1).pdf PDF
36C77623B0058 0002.docx DOCX document
Att 1 Volume 1 - General and Civil_Combined.pdf PDF
DBA Wage Rates Construction - Ross Cty.pdf PDF
36C77623B0058 0001.docx DOCX document
Attachment 04 - DBA Wage Determination.pdf PDF
Updated _Specifications_Combined.pdf PDF
Attachment 08 - SOW attach Volume 1 Part 3.pdf PDF
Attachment 04 - Wage Rate Determination - Chillicothe.pdf PDF
Attachment 11 - SOW attach Volume 1 Part 6.pdf PDF
Attachment 19 - SOW attach Volume 3 Part 4.pdf PDF
Attachment 17 - SOW attach Volume 3 Part 2.pdf PDF
Show 40 more

Latest 50 of 65 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T

024-AE101.1

Toilet

112A

Bed Room

112B Bed Room

112C

Entry

Toilet

113A

Bed Room

113BBed Room

113C

Entry

Corridor

1C4

Bed Room

114A Bed Room

114B

Entry

Toilet

114C Bed Room

Toilet

115A

HAC

MHRRTP Screener

Psychologist

118Library

Bed Room

108C

Toilet

108B

Elect. Room

Bed Room

106A

Entry

Bed Room

107C Bed Room

107A

Toilet

107B

Stairs

1BS1

Dietician

Interview Room

Staff Work Room

Storage

120A

Linen Chute

Laundry Room

Toilet

122A

Toilet

Nurse Manager

Corridor

Corridor

1C5

Conference Room

124A

Entry

Entry

Entry

Bed Room

108A Bed Room

106C

Nurse Station

Day Room

Corridor

1C3

Corridor

1C2

Corridor

1C1

Toilet

106B

124E Tele Clos

Conference Room

124A

124E

Tele Clos

Corridor

1C5

Entry

DEMOLITION BOUNDARY

TR

Conference Room

124A

Corridor

1C5

Entry

ALIGN WALLS

7 8

TR

Conference Room

124A

124E

Tele Clos

TR

A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.

B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.

G E N E R A L D E M O L I T I O N N O T E S

G E N E R A L C O N S T R U C T I O N N O T E S

A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.

B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.

C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED

OTHERWISE.

D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER

MANUFACTURER'S WRITTEN INSTRUCTIONS.

E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE

ACCORDINGLY.

F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.

G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.

H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO

MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.

I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.

J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED

OTHERWISE.

K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE

STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.

L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A

PARTITION BRACING ELEMENT.

M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.

N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER

REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.

O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION

P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.

S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED

WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:0

:3

P

M

024-AE101.1

FIRST FLOOR ZONE 1 - TR PLANS

03/17/2023 PQ JF

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 024

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N

1/8" = 1'-0"

B24 - FIRST FLOOR - ZONE 1

D R A W I N G N O T E S :

1 NO CEILING IN THIS AREA

2 REMOVE CEILING SYSTEMS AND SUPPORTS

3 REMOVE WALL

4 REMOVE EXISTING FLOORING FINISH AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR

INSTALLATION OF ELECTRIC DISSIPATING FLOORING DURING CONSTRUCTION.

5 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND

CONDUIT. PAINT WHITE ALL BUT FIRE RATING LABEL.

6 WINDOW SECURITY BARS - INSTALLED ON INTERIOR OF WINDOW OPENING

7 INSTALL ELECTRICAL DISSIPATING FLOOR PAINT - SEE HATCHED AREA

8 MOUNT AND PROVIDE NEW ABC FIRE EXTINGUISHER

N

1/4" = 1'-0"

B24 - FIRST FLOOR - TR DEMO

N

1/4" = 1'-0"

B24 - FIRST FLOOR - TR NEW WORK

N

1/4" = 1'-0"

B24 - FIRST FLOOR PLAN - TR - DEMO RCP

N

1/4" = 1'-0"

B24 - FIRST FLOOR PLAN - TR - NEW WORK RCP

ZONE 1 ZONE 2

024-AE102.1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:0

:3

P

M

024-AE102

OVERALL SECOND FLOOR PLAN

03/17/2023 PQ JF

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 024

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N

1/8" = 1'-0"

B24 - SECOND FLOOR

T

024-AE102.1

Toilet

213A

Bed Room

213B Bed Room

213C

Entry

Toilet

214A

Entry

Bed Room

214B Bed Room

214C

Corridor

2C3

Bed Room

215A Bed Room

215B

Entry

Toilet

215C

Bed Room

Toilet

216A

Physician Assist/Exam

Laundry Room

Soiled Linen

219A

Linen Chute

Crash Carts

Storage

221A

EXAM ROOM

Tele Clos

Day Rm/Training

Corridor

2C4

Addiction Therapist

Equipment

Med. Room

201A

EXAM ROOM

Social Worker

Detox Coordinator

Stairs

2S3

Bed Room

206A

Toilet

206B

Bed Room

207A

Toilet

207B

Entry

Bed Room

207C

Bed Room

208A

Toilet

208B

Elect. Room

Library

HAC

Entry

Bed Room

206C

Entry

Bed Room

208C

Corridor

2C2

Corridor

2C1

Nurse Station

Day Room

Toilet

217A

Day Rm/Training

Tele Clos

Corridor

2C4

DEMOLITION BOUNDARY

/2

1' - 0" 10' - 6"

Tele Clos

1' - 0"

DEMOLITION BOUNDARY

/4

Day Rm/Training

Tele Clos

Corridor

2C4

Tele Clos

A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.

B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.

G E N E R A L D E M O L I T I O N N O T E S

G E N E R A L C O N S T R U C T I O N N O T E S

A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.

B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.

C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED

OTHERWISE.

D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER

MANUFACTURER'S WRITTEN INSTRUCTIONS.

E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE

ACCORDINGLY.

F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.

G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.

H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO

MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.

I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.

J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED

OTHERWISE.

K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE

STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.

L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A

PARTITION BRACING ELEMENT.

M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.

N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER

REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.

O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION

P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.

S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED

WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:0

:5

P

M

024-AE102.1

SECOND FLOOR PLAN - TR PLANS

03/17/2023 PQ JF

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 024

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N

1/8" = 1'-0"

B24 - SECOND FLOOR - ZONE 1

D R A W I N G N O T E S :

1 REMOVE WALL

2 REMOVE WALL BASE ALONG THIS WALL - LEADER ARROW POINTS TO WALL SURFACE

3 REMOVE CEILING SYSTEMS AND SUPPORTS

4 EXISTING MOUNTED PLYWOOD TO REMAIN, TYPICAL.

5 REMOVE EXISTING FLOORING FINISH AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR

INSTALLATION OF ELECTRIC DISSIPATING FLOORING DURING CONSTRUCTION.

6 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND

CONDUIT. PAINT WHITE ALL BUT FIRE RATING LABEL.

7 INSTALL ELECTRICAL DISSIPATING FLOOR PAINT - SEE HATCHED AREA

8 NEW WALL - REFER TO GI001 FOR WALL TYPE DETAIL - 1 HR FIRE RATING

9 INSTALL WALL BASE, MATCH EXISTING BASE.

10 NO CEILING IN THIS AREA

11 MOUNT AND PROVIDE NEW ABC FIRE EXTINGUISHER

N

1/4" = 1'-0"

B24 - SECOND FLOOR - TR - DEMO

N

1/4" = 1'-0"

B24 - SECOND FLOOR - TR - NEW WORK

N

1/4" = 1'-0"

B24 - SECOND FLOOR PLAN - TR - DEMO RCP

N

1/4" = 1'-0"

B24 - SECOND FLOOR PLAN - TR - NEW WORK RCP

025-AE100

VOC Assembly

101A

VOC Recycle

Office

VOC Office

104A

VOC Office

Toilet

Shower

Shower

Toilet

Linen Distribution

Toilet

102B

LINEN DISTRIBUTION

102C Laundry Manager

Elect. Room

101B

Room

2B

TELE CLOS

102D

BREAK ROOM

102A

2-5

DEMOLITION BOUNDARY

TELE CLOS

102D

LINEN DISTRIBUTION

102C

TR

102D

VOC Recycle

BREAK ROOM

102A

LINEN DISTRIBUTION

102C

9' - 1 3/4"

102D

TELE CLOS

102D

LINEN DISTRIBUTION

102C

BREAK ROOM

102A

VOC Recycle

TR

102D

G E N E R A L C O N S T R U C T I O N N O T E S

A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.

B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.

C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED

OTHERWISE.

D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER

MANUFACTURER'S WRITTEN INSTRUCTIONS.

E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE

ACCORDINGLY.

F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.

G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.

H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO

MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.

I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.

J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED

OTHERWISE.

K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE

STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.

L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A

PARTITION BRACING ELEMENT.

M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.

N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER

REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.

O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION.

P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.

S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED

WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.

A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.

B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.

G E N E R A L D E M O L I T I O N N O T E S

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:0

:0

P

M

025-AE100

OVERALL FLOOR PLANS

03/17/2023 PQ JF

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 025

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N

1/8" = 1'-0"

B25-FIRST FLOOR

N

1/4" = 1'-0"

B25-FIRST FLOOR - TR - DEMO

N

1/4" = 1'-0"

B25-FIRST FLOOR - TR - NEW WORK

N

1/4" = 1'-0"

B25-FIRST FLOOR PLAN - TR - DEMO RCP

N

1/4" = 1'-0"

B25-FIRST FLOOR PLAN - TR - NEW WORK RCP

D R A W I N G N O T E S :

1 REMOVE EXISTING FLOORING FINISH AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR

INSTALLATION OF ELECTRIC DISSIPATING FLOORING DURING CONSTRUCTION.

2 NO CEILING IN THIS AREA

3 REMOVE WALL

4 REMOVE EXISTING DOOR FRAME AND DOOR LEAF; TURN DOOR LEAF OVER TO VA TO ADD TO EXISTING STOCK.

5 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND

CONDUIT. PAINT WHITE ALL BUT FIRE RATING LABEL.

6 EXISTING MOUNTED PLYWOOD TO REMAIN, TYPICAL.

7 REMOVE PORTION OF WALL SYSTEM FOR FUTURE INSTALLATION OF DOOR FRAME AND DOOR LEAF.

8 PATCH WALL OPENING OF REMOVED DOOR/WINDOW WITH COLD-FORMED METAL FRAMING AND TYPE X GYPSUM BOARD

TO MATCH EXISTING. MAINTAIN 1 HR FIRE RATING.

9 INSTALL WALL BASE, MATCH EXISTING BASE.

10 NEW WALL - REFER TO GI001 FOR WALL TYPE DETAIL - 1 HR FIRE RATING

11 MOUNT AND PROVIDE NEW ABC FIRE EXTINGUISHER

DN

ZONE 1

ZONE 2 ZONE 3

ZONE 4

026-AE100.1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:0

:0

P

M

026-AE100

OVERALL BASEMENT FLOOR PLAN

03/17/2023 PQ JF

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 026

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N

1/8" = 1'-0"

B26 - BASEMENT

026-AE100.1

TR

Social Work Service

TR

Social Work Service

159 SF

TR

A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.

B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.

G E N E R A L D E M O L I T I O N N O T E S

G E N E R A L C O N S T R U C T I O N N O T E S

A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.

B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.

C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED

OTHERWISE.

D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER

MANUFACTURER'S WRITTEN INSTRUCTIONS.

E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE

ACCORDINGLY.

F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.

G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.

H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO

MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.

I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.

J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED

OTHERWISE.

K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE

STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.

L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A

PARTITION BRACING ELEMENT.

M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.

N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER

REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.

O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION

P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.

S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED

WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:0

:2

P

M

026-AE100.1

BASEMENT FLOOR PLAN - TR

PLANS

03/17/2023 PQ JF

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 026

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N

1/8" = 1'-0"

B26 - BASEMENT FLOOR PLAN - ZONE 1

N

1/4" = 1'-0"

B26 - BASEMENT FLOOR PLAN - TR - DEMO

N

1/4" = 1'-0"

B26 - BASEMENT FLOOR PLAN - TR - NEW WORK

N

1/4" = 1'-0"

B26 - BASEMENT - TR - DEMO RCP

N

1/4" = 1'-0"

B26 - BASEMENT - TR - NEW WORK RCP

D R A W I N G N O T E S :

1 REMOVE EXISTING FLOORING FINISH AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR

INSTALLATION OF ELECTRIC DISSIPATING FLOORING DURING CONSTRUCTION.

2 REMOVED AND REPLACE FRAME AND LOCKSET AS REQUIRED FOR CARD READER. REUSE REMAINING HARDWARE

3 REMOVE CEILING SYSTEMS AND SUPPORTS

4 NEW WALL - REFER TO GI001 FOR WALL TYPE DETAIL - 1 HR FIRE RATING

5 WINDOW SECURITY BARS - INSTALLED ON INTERIOR OF WINDOW OPENING

6 INSTALL ELECTRICAL DISSIPATING FLOOR PAINT - SEE HATCHED AREA

7 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND

CONDUIT. PAINT WHITE ALL BUT FIRE RATING LABEL.

8 NO CEILING IN THIS AREA

9 MOUNT AND PROVIDE NEW ABC FIRE EXTINGUISHER

10 EXISTING MOUNTED PLYWOOD TO REMAIN, TYPICAL.

2-5

ZONE 2 ZONE 3

ZONE 4

026-AE101.1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:0

:3

P

M

026-AE101

OVERALL FIRST FLOOR PLAN

03/17/2023 Checker Author

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 026

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N

1/8" = 1'-0"

B26 - FIRST FLOOR

E M

EM

E M

E M

E M

EM

EM

EM

K

026-AE101.1

DATA

DATA

TR

DATA

TR

A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.

B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.

G E N E R A L D E M O L I T I O N N O T E S

G E N E R A L C O N S T R U C T I O N N O T E S

A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.

B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.

C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED

OTHERWISE.

D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER

MANUFACTURER'S WRITTEN INSTRUCTIONS.

E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE

ACCORDINGLY.

F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.

G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.

H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO

MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.

I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.

J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED

OTHERWISE.

K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE

STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.

L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A

PARTITION BRACING ELEMENT.

M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.

N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER

REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.

O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION

P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.

S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED

WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:0

:5

P

M

026-AE101.1

FIRST FLOOR PLAN - TR PLANS

03/17/2023 Checker Author

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 026

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N

1/8" = 1'-0"

B26 - FIRST FLOOR PLAN - ZONE 1

N

1/4" = 1'-0"

B26 - FIRST FLOOR PLAN - TR - DEMO

N

1/4" = 1'-0"

B26 - FIRST FLOOR PLAN - TR - NEW WORK

N

1/4" = 1'-0"

B26 - FIRST FLOOR - TR - DEMO RCP

N

1/4" = 1'-0"

B26 - FIRST FLOOR - TR - NEW WORK RCP

D R A W I N G N O T E S :

1 Existing Slab

2 NO CEILING IN THIS AREA

3 MOUNT AND PROVIDE NEW ABC FIRE EXTINGUISHER

4 INSTALL ELECTRICAL DISSIPATING FLOOR PAINT - SEE HATCHED AREA

5 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND

CONDUIT. PAINT WHITE ALL BUT FIRE RATING LABEL.

6 EXISTING MOUNTED PLYWOOD TO REMAIN, TYPICAL.

ZONE 2 ZONE 3

026-AE102.1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:0

:5

P

M

026-AE102

OVERALL SECOND FLOOR PLAN

03/17/2023 Checker Author

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 026

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N

1/8" = 1'-0"

B26 - SECOND FLOOR

026-AE102.1

Room

TR

200A

D E

M O

LI

T

IO

N

B O

U N

D A

R Y

BREAK ROOM

5"

1' - 0"3' - 0"6"

TR

200A

200A

D E

M O

LI

T

IO

N

B O

U N

D A

R Y

BREAK ROOM

TR

200A

A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.

B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.

G E N E R A L D E M O L I T I O N N O T E S

G E N E R A L C O N S T R U C T I O N N O T E S

A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.

B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.

C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED

OTHERWISE.

D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER

MANUFACTURER'S WRITTEN INSTRUCTIONS.

E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE

ACCORDINGLY.

F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.

G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.

H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO

MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.

I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.

J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED

OTHERWISE.

K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE

STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.

L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A

PARTITION BRACING ELEMENT.

M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.

N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER

REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.

O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION

P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.

S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED

WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:0

:1

P

M

026-AE102.1

SECOND FLOOR PLAN - TR PLANS

03/17/2023 PQ JF

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 026

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N

1/8" = 1'-0"

B26 - SECOND FLOOR PLAN - ZONE 1

N

1/4" = 1'-0"

B26 - SECOND FLOOR PLAN - TR - DEMO

N

1/4" = 1'-0"

B26 - SECOND FLOOR PLAN - TR - NEW WORK

N

1/4" = 1'-0"

B26 - SECOND FLOOR - TR - DEMO RCP

N

1/4" = 1'-0"

B26 - SECOND FLOOR - TR - NEW WORK RCP

D R A W I N G N O T E S :

1 REMOVE EXISTING FLOORING FINISH AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR

INSTALLATION OF ELECTRIC DISSIPATING FLOORING DURING CONSTRUCTION.

2 REMOVE CEILING SYSTEMS AND SUPPORTS

3 INSTALL ELECTRICAL DISSIPATING FLOOR PAINT - SEE HATCHED AREA

4 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND

CONDUIT. PAINT WHITE ALL BUT FIRE RATING LABEL.

5 NO CEILING IN THIS AREA

6 WINDOW SECURITY BARS - INSTALLED ON INTERIOR OF WINDOW OPENING

7 MOUNT AND PROVIDE NEW ABC FIRE EXTINGUISHER

8 NEW WALL - REFER TO GI001 FOR WALL TYPE DETAIL - 1 HR FIRE RATING

9 INSTALL WALL BASE ALONG WALL

10 PAINT WALLS - REFER TO FINISH SCHEDULE

11 REMOVE PORTION OF WALL SYSTEM FOR FUTURE INSTALLATION OF DOOR FRAME AND DOOR LEAF.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:0

:1

P

M

027-AE100

OVERALL BASEMENT FLOOR PLAN

03/17/2023 Checker Author

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 027

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N

1/8" = 1'-0"

B27 - BASEMENT

027-AE100.1

Mechanical

Toilet

Toilet

Soiled Linen

13 TR

Elevator Equipment

Optometry Waiting

Corridor

Tele Clos

HAC

Mechanical

Toilet

Elec Switchgear

Elevator Equipment

Corridor

1B

Corridor

1A

Corridor

1C Vending Area

1D

Storage

17G

Infection Control

17F

MDRO prevention Coordinator

17E

Infection Control Nurse

17D

EMS Supervisor

17B

RME Coordinator

17A

MAS Secretary

17C

Toilet

32B

Linen Chute

13A

Corridor

1E

Optometry

16A

16B

Stairs

000B

Stairs

000A

Closet

16C

2-5

DATA

TR

DATA

TR

A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.

B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.

G E N E R A L D E M O L I T I O N N O T E S

G E N E R A L C O N S T R U C T I O N N O T E S

A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.

B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.

C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED

OTHERWISE.

D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER

MANUFACTURER'S WRITTEN INSTRUCTIONS.

E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE

ACCORDINGLY.

F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.

G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.

H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO

MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.

I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.

J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED

OTHERWISE.

K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE

STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.

L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A

PARTITION BRACING ELEMENT.

M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.

N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER

REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.

O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION

P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.

S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED

WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:0

:3

P

M

027-AE100.1

BASEMENT FLOOR ZONE 1 - TR

PLANS

03/17/2023 PQ JF

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 027

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N

1/8" = 1'-0"

B27 - BASEMENT - ZONE 1

N

1/4" = 1'-0"

B27 - BASEMENT - TR - DEMO

N

1/4" = 1'-0"

B27 - BASEMENT - TR - NEW WORK

N

1/4" = 1'-0"

B27 - BASEMENT FLOOR PLAN - TR - DEMO RCP

N

1/4" = 1'-0"

B27 - BASEMENT FLOOR PLAN - TR - NEW WORK RCP

D R A W I N G N O T E S :

1 NO CEILING IN THIS AREA

2 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND

CONDUIT. PAINT WHITE ALL BUT FIRE RATING LABEL.

3 EXISTING MOUNTED PLYWOOD TO REMAIN, TYPICAL.

4 REMOVE EXISTING FLOORING FINISH AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR

INSTALLATION OF ELECTRIC DISSIPATING FLOORING DURING CONSTRUCTION.

5 INSTALL ELECTRICAL DISSIPATING FLOOR PAINT - SEE HATCHED AREA

6 MOUNT AND PROVIDE NEW ABC FIRE EXTINGUISHER

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:0

:4

P

M

027-AE101

OVERALL FIRST FLOOR PLAN

03/17/2023 Checker Author

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 027

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N

1/8" = 1'-0"

B27 - FIRST FLOOR

027-AE101.1

Waiting

Visitor

Optometry Exam

Optometry Exam

Linen Chute

Soiled Utility

Retinal Exam

Tele Clos

131 Ice Machine

Pat Ed & Visit Coor

Toilet

Women's Veteran Program Manager

Break Room

Conference Room

Women's Health Diagnostic Coordinator

GECL Physician's Assistant

Centeral Check In

140 Neurology

Soiled Utility

Exam Room

UV Room

Associate Chief Nurse

TR

Corridor

100A

Corridor

100B

Corridor

100C

Corridor

100D

Corridor

100E

Corridor

100I

ASSOCIATE CHEIF NURSE

TR

ASSOCIATE CHEIF NURSE

TELECOMM. ROOM

A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.

B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.

G E N E R A L D E M O L I T I O N N O T E S

G E N E R A L C O N S T R U C T I O N N O T E S

A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.

B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.

C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED

OTHERWISE.

D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER

MANUFACTURER'S WRITTEN INSTRUCTIONS.

E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE

ACCORDINGLY.

F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.

G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.

H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO

MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.

I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.

J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED

OTHERWISE.

K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE

STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.

L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A

PARTITION BRACING ELEMENT.

M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.

N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER

REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.

O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION

P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.

S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED

WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:0

:0

P

M

027-AE101.1

FIRST FLOOR ZONE 1 - TR PLANS

03/17/2023 PQ JF

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 027

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N

1/8" = 1'-0"

B27 - FIRST FLOOR - ZONE 1

N

1/4" = 1'-0"

B27 - FIRST FLOOR - TR - DEMO

N

1/4" = 1'-0"

B27 - FIRST FLOOR - TR - NEW WORK

N

1/4" = 1'-0"

B27 - FIRST FLOOR PLAN - TR - DEMO RCP

N

1/4" = 1'-0"

B27 - FIRST FLOOR PLAN - TR - NEW WORK RCP

D R A W I N G N O T E S :

1 REMOVE EXISTING FLOORING FINISH AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR

INSTALLATION OF ELECTRIC DISSIPATING FLOORING DURING CONSTRUCTION.

2 INSTALL ELECTRICAL DISSIPATING FLOOR PAINT - SEE HATCHED AREA

3 REMOVED AND REPLACE FRAME AND LOCKSET AS REQUIRED FOR CARD READER. REUSE REMAINING HARDWARE

4 NO CEILING IN THIS AREA

5 Casework To Be Removed

6 REMOVE CEILING SYSTEMS AND SUPPORTS

7 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND

8 WINDOW SECURITY BARS - INSTALLED ON INTERIOR OF WINDOW OPENING

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:0

:0

P

M

027-AE102

OVERALL SECOND FLOOR PLAN

03/17/2023 Checker Author

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 027

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N.T.S.Scale:

B27 - SECOND FLOOR

027-AE102.1

Pain Clinic Check In

Release of Information

Pain Clinic Waiting

Toilet

Chiropractor

Pain Coordinator

GI Clerical

Linen Chute

GI Clinic Lounge

Tele Clos

235 Storage

PBS Kitchenette

Toilet

Exam Room

Pain Management Storage

Conference Room

Psychologist

Clinical Pharmacist

Physician

Physician

Staff Neurologist

TR

Corridor

200A

Corridor

200C

Corridor

200B

Corridor

200D

Corridor

200B1

Corridor

200B2

Toilet

234A

TR

100 SF

TR

TR

TR

A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.

B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.

G E N E R A L D E M O L I T I O N N O T E S

G E N E R A L C O N S T R U C T I O N N O T E S

A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.

B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.

C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED

OTHERWISE.

D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER

MANUFACTURER'S WRITTEN INSTRUCTIONS.

E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE

ACCORDINGLY.

F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.

G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.

H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO

MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.

I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.

J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED

OTHERWISE.

K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE

STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.

L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A

PARTITION BRACING ELEMENT.

M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.

N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER

REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.

O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION

P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.

S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED

WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:0

:2

P

M

027-AE102.1

SECOND FLOOR ZONE 1 - TR

PLANS

03/17/2023 PQ JF

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 027

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N

1/8" = 1'-0"

B27 - SECOND FLOOR - ZONE 1

N

1/4" = 1'-0"

B27 - SECOND FLOOR - DEMO

N

1/4" = 1'-0"

B27 - SECOND FLOOR - NEW WORK

N

1/4" = 1'-0"

B27 - SECOND FLOOR PLAN - TR - DEMO RCP

N

1/4" = 1'-0"

B27 - SECOND FLOOR PLAN - TR - NEW WORK RCP

D R A W I N G N O T E S :

1 REMOVE EXISTING FLOORING FINISH AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR

INSTALLATION OF ELECTRIC DISSIPATING FLOORING DURING CONSTRUCTION.

2 REMOVE CEILING SYSTEMS AND SUPPORTS

3 NO CEILING IN THIS AREA

4 INSTALL ELECTRICAL DISSIPATING FLOOR PAINT - SEE HATCHED AREA

028-AE102

Canteen Salon

CRC Office

Social Worker

Social Worker Supervisor

Canteen Storage

Toilet

Social Work Supervisor

Copy/File Room

Waiting

MHICM Case Manager

Toilet

Conference Room

MHICM Case Manager

MHICM Case Manager

MHCIM Case Manager

CRC/MHICM Program Manager

Medical Foster Home Coordinator

Closet

210A

Secretary Social Work Service

210B

Chief, Social Worker Service

210C

CRC/MHICM Program Support Assistant

210D

Closet

201A

Closet

202A

Closet

203A

Closet

204A

Closet

205A

Closet

205B

HAC

207A

Closet

208A

Closet

208B

Closet

209A

Closet

209B Closet

2011A

Closet

2011B

HAC

212A

Closet

214A

Closet

215A

Closet

216A

Closet

217A

Closet

218A

Corridor

Corridor

200A Stairs

Stairs

Elevator Lobby

Stairs

2-5

Tele. Closet

TELE. CLOSET

TR

TELE. CLOSET

TR

A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.

B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.

G E N E R A L D E M O L I T I O N N O T E S

G E N E R A L C O N S T R U C T I O N N O T E S

A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.

B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.

C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED

OTHERWISE.

D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER

MANUFACTURER'S WRITTEN INSTRUCTIONS.

E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE

ACCORDINGLY.

F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.

G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.

H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO

MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.

I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.

J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED

OTHERWISE.

K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE

STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.

L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A

PARTITION BRACING ELEMENT.

M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.

N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER

REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.

O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION

P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.

S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED

WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:0

:3

P

M

028-AE102

OVERALL SECOND FLOOR

03/17/2023 Checker Author

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 028

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N

1/8" = 1'-0"

B28 - SECOND FLOOR

N

1/4" = 1'-0"

B28 - SECOND FLOOR - TR - DEMO

N

1/4" = 1'-0"

B28 - SECOND FLOOR - TR - NEW WORK

N

1/4" = 1'-0"

B28 - SECOND FLOOR - TR - DEMO RCP

N

1/4" = 1'-0"

B28 - SECOND FLOOR - TR - NEW WORK RCP

D R A W I N G N O T E S :

1 REMOVE EXISTING FLOORING FINISH AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR

INSTALLATION OF ELECTRIC DISSIPATING FLOORING DURING CONSTRUCTION.

2 NO CEILING IN THIS AREA

3 REMOVE WALL

4 REMOVE EXISTING DOOR FRAME AND DOOR LEAF; TURN DOOR LEAF OVER TO VA TO ADD…