This document provides details on a federal contract opportunity for construction services. The solicitation is number 36C77623B0058 from the Department of Veterans Affairs Technology Acquisition Center Austin for infrastructure upgrades at the Chillicothe, Ohio VA medical center. The opportunity involves upgrading the electrical, HVAC, and related building systems at the facility. The contract type will be firm-fixed-price, with the period of performance running from date of award through December 2023. The estimated value is between $5-10 million. Responses are due by July 20, 2021 and the agency anticipates making an award by September 2021.
View the file
Other files
Show 40 more
Latest 50 of 65 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N
N
CHILLICOTHE VA MEDICAL CENTER
PROJECT NUMBER: 538-21-701
DEPARTMENT OF VETERANS AFFAIRS
273 STATE ROUTE 104, CHILLICOTHE, OHIO 45601
EHRM INFRASTRUCTURE UPGRADES
VOLUME 3 OF 13
G E N E R A L N O T E S
A. SEE GENERAL PROJECT NOTES FOR NEW WORK FOR ADDITIONAL REQUIREMENTS FOR WORK WITHIN THE
EXISTING FACILITY. THE CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND FIELD CONDITIONS
PRIOR TO DEMOLITION AND CONSTRUCTION. IF PROVIDED, THE GENERAL CONTRACTOR SHALL EXAMINE
EXISTING BUILDING DOCUMENTS. THE CONTRACTOR SHALL BRING ANY DISCREPANCIES TO THE
IMMEDIATE ATTENTION OF THE C.O.R. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF
EXISTING ITEMS TO REMAIN DURING DEMOLITION AND CONSTRUCTION. MAINTAIN EXIT EGRESS PATHS
TO EXISTING EXIT DOORS DURING CONSTRUCTION.
B. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL CONSTRUCTION ROUTES BEYOND THE
AREAS OF WORK AND THE ROUTES MUST BE RETURNED TO THEIR ORIGINAL CONDITION AT THE END OF
THE PROJECT.
C. ALL DEMOLITION AND CONSTRUCTION ACTIVITIES SHALL BE COORDINATED WITH THE C.O.R. TO MINIMIZE
DISRUPTIONS OF NORMAL FUNCTIONS OF THE VA'S OCCUPIED AREAS.
D. IF CONSTRUCTION NOISE IS ANTICIPATED, SUBMIT A WRITTEN REQUEST TO THE C.O.R. FOR THE
SCHEDULED TIME OF THE CONSTRUCTION ACTIVITIES. NO WORK SHALL BE DONE WITHOUT THE WRITTEN
APPROVAL OF THE C.O.R. THE C.O.R. RESERVES THE RIGHT TO DISCONTINUE NOISY CONSTRUCTION AT
ANY TIME. NO RADIOS SHALL BE PERMITTED AT ANY TIME IN WORK AREAS ADJACENT TO OCCUPIED
SPACES.
E. ALL EXISTING SERVICES AND UTILITIES SHALL BE MAINTAINED TO AREAS THAT ARE IN OPERATION AND
SERVED BY THEM. COORDINATE ALL DISRUPTIONS OR DISCONTINUATIONS OF UTILITIES AND SERVICES
WITH C.O.R. NO SHUT DOWN OF EXISTING SERVICES IS ALLOWED TO OCCUR UNTIL RECEIVING THE
C.O.R.'S WRITTEN APPROVAL OF THE SHUT DOWN SCHEDULE. PROVIDE TEMPORARY SERVICES AND/OR
UTILITIES DURING INTERRUPTIONS AS REQUIRED AND APPROVED BY THE C.O.R.
F. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PREVENT DAMAGE TO THE V.A.'S
AREAS ADJACENT TO NEW CONSTRUCTION OR AREAS WHERE VARIOUS SYSTEM CONNECTIONS OR
EXTENSIONS ARE REQUIRED. IN THESE AREAS, THE CONTRACTOR IS RESPONSIBLE FOR DAMAGE
CAUSED BY LACK OF SUFFICIENT PROTECTION FROM THE WEATHER AND FROM THE RESULTS OF ALL
CONSTRUCTION ACTIVITY INCLUDING BUT NOT LIMITED TO DUST AND WATER.
G. THE CONTRACTOR SHALL RECEIVE WRITTEN APPROVAL FROM THE C.O.R. BEFORE USING OPEN FLAMES, WELDING RODS AND TORCHES. THE CONTRACTOR IS RESPONSIBLE FOR ALL MEANS AND METHODS TO
PROHIBIT THE MIGRATION OF SMOKE AND OTHER PRODUCTS OF COMBUSTION INTO OCCUPIED AREAS OF
THE EXISTING BUILDING AND FOR OBTAINING ALL REQUIRED PERMITS RELATED TO HOT WORK.
H. DO NOT OVERLOAD THE EXISTING BUILDING STRUCTURE. MAINTAIN THE STRUCTURAL INTEGRITY OF ALL
STRUCTURAL FRAMING MEMBERS AND SYSTEMS AT ALL TIMES.
I. ALL DEMOLISHED MATERIAL, EXCEPT MATERIAL THAT IS LISTED OR MARKED FOR RETENTION, SHALL
BECOME THE PROPERTY OF THE CONTRACTOR AND IT SHALL BE DISPOSED OF. NO DEBRIS RESULTING
FROM WORK SHALL BE LEFT IN THE CONSTRUCTION ROUTES BEYOND THE AREAS OF WORK.
J. REMOVAL OF A PARTICULAR ITEM IS TO INCLUDE ALL RELATED ITEMS, SUCH AS REMOVAL OF WALLS
WOULD INCLUDE ASSOCIATED DOORS, HARDWARE, ELECTRICAL, PLUMBING, MECHANICAL, ETC. REFER
TO DEMOLITION DRAWINGS FOR MORE INFORMATION. FOR ALL REMOVALS, THE GENERAL CONTRACTOR
AND SUBCONTRACTORS SHALL COORDINATE WITH ALL OTHER DISCIPLINES.
K. THE CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT FOR ITEMS NOT DEMOLISHED OR REMOVED
AS REQUIRED UNTIL PERMANENT SUPPORT IS PROVIDED IN THE FINAL CONSTRUCTION.
L. ALL OPENINGS IN EXISTING WALLS, CEILINGS AND FLOORS, WHICH ARE THE RESULT OF REMOVALS AND
OTHER NEW CONSTRUCTION ACTIVITY, SHALL BE PATCHED WITH NEW MATERIALS THAT MATCH THE
EXISTING MATERIALS OR AS NOTED ON DRAWINGS. IF THE PATCH IS TO BE MADE IN FIRE RATED
CONSTRUCTION, THE PATCH MUST ACHIEVE THE REQUIRED FIRE RATING. THE PATCH SHALL BE FINISHED
TO A LIKE NEW CONDITION TO MATCH THE EXISTING FINISH.
M. ALL EXISTING OPENINGS IN CEILINGS, FLOORS AND WALLS DISCOVERED IN THE EXISTING STRUCTURE
SHALL BE PATCHED WITH NEW MATERIALS THAT MATCH THE EXISTING MATERIALS. IF THE PATCH IS TO
BE MADE IN FIRE RATED CONSTRUCTION, THE PATCH MUST ACHIEVE THE REQUIRED FIRE RATING. THE
PATCH SHALL BE FINISHED TO A LIKE NEW CONDITION TO MATCH THE EXISTING FINISH.
N. WHERE EXISTING SURFACES ARE TO BE REFINISHED OR ARE TO SERVE AS SUBSTRATE FOR THE
ATTACHMENT OR APPLICATION OF NEW MATERIALS OR CONSTRUCTION, PREPARE OR ALTER THE
EXISTING SURFACES AS NECESSARY TO PROPERLY ACCOMMODATE THE NEW MATERIALS.
O. FIELD VERIFY SIZES AND DIMENSIONS OF ALL EXISTING UTILITIES THAT IMPACT THE NEW WORK.
DETERMINE THE SIZE AND LOCATION THE PENETRATIONS FROM THE EXISTING UTILITIES WITHIN THE NEW
WORK. SEAL TIGHT TO ALL PENETRATIONS AND CAULK.
P. PENETRATIONS THROUGH EXISTING FIRE RATED CONSTRUCTION MUST BE PROPERLY CLOSED AND FIRE
SAFE'D TO ACHIEVE THE REQUIRED FIRE RATING BY THE END OF CONSTRUCTION OPERATIONS FOR EACH
DAY.
Q. NEW HOLES IN EXISTING ROOF STRUCTURES FOR NEW WORK MUST BE COORDINATED WITH THE
EXISTING STRUCTURE SO THAT CRITICAL STRUCTURAL MEMBERS ARE NOT DAMAGED.
R. UNLESS OTHERWISE NOTED, THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISTING
SALVAGED STOCK BEFORE ORDERING NEW MATERIAL.
E X I S T I N G F A C I L I T I E S:
A. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND FEDERAL AUTHORITIES, CODES, RULES AND REGULATIONS.
B. THESE DOCUMENTS SHOW THE MINIMUM CONSTRUCTION REQUIREMENTS AND THE MINIMUM QUALITY OF
WORK EXPECTED. MORE STRINGENT REQUIREMENTS STIPULATED WITHIN RELEVANT MANUFACTURER’S
INSTALLATION INSTRUCTIONS WILL SUPERSEDE.
C. ANY UNFORESEEN OR UNCLEAR CONDITIONS SHALL BE REPORTED TO THE C.O.R. PRIOR TO PROCEEDING
WITH WORK.
D. ANY CONFLICTS WITHIN THE DRAWINGS, BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, OR
BETWEEN THE DRAWINGS AND THE ACTUAL CONDITIONS AT THE SITE, ARE TO BE BROUGHT TO THE
IMMEDIATE ATTENTION OF THE C.O.R. THE CONTRACTOR SHALL NOT PROCEED WITH WORK UNTIL
WRITTEN CLARIFICATION FROM THE ARCHITECT/ENGINEER IS RECEIVED.
E. UNLESS OTHERWISE NOTED, ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED PER THE APPLICABLE
PROVISIONS OF THESE DOCUMENTS AND THE MANUFACTURER’S INSTRUCTIONS.
F. ALL MATERIALS USED SHALL BE NEW UNLESS OTHERWISE NOTED AND/OR OF A QUALITY TO MEET OR
EXCEED ALL APPLICABLE INDUSTRY STANDARDS. WHERE SPECIFIED PRODUCTS OR MANUFACTURERS
ARE NOT NOTED, THE CONTRACTOR IS REQUIRED TO NOTIFY THE ARCHITECT TO OBTAIN A MINIMUM
STANDARD OF QUALITY.
G. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL MEANS, METHODS AND TECHNIQUES FOR
CONSTRUCTION.
H. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR JOB-SITE SAFETY INCLUDING THE ADHERENCE TO
OSHA REGULATIONS.
I. ALL ELECTRICAL AND MECHANICAL WORK SHALL BE PERFORMED BY PERSONNEL LICENSED IN THE STATE
WHERE THIS PROJECT IS LOCATED.
J. REMOVE ALL DEBRIS PROPERLY FROM THE SITE. LOAD DEBRIS DIRECTLY ONTO TRUCKS FOR REMOVAL.
DISPOSE OF DEBRIS LEGALLY. DO NOT BURN DEBRIS ON THE SITE. DO NOT ALLOW DEBRIS TO ENTER
SEWERS. DO NOT ALLOW PILED DEBRIS TO ENDANGER STRUCTURES, BLOCK EXISTS OR ROADWAYS.
COMBUSTIBLE WASTE WHICH COULD CREATE A FIRE HAZARD SHALL NOT BE PERMITTED TO ACCUMULATE
IN OR AROUND THE CONSTRUCTION SITE.
K. COORDINATE ALL WORK WITH ALL OTHER DISCIPLINES, INCLUDING, EXACT SIZE AND LOCATION OF ALL
ROOF AND FLOOR OPENINGS SHOWN ON ARCHITECTURAL DRAWINGS SHALL BE VERIFIED WITH THE
ASSOCIATED SUB-CONTRACTORS PRIOR TO CONSTRUCTION.
L. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL GOVERN. ALL PLAN DIMENSIONS ARE TAKEN TO FINISH
FACE OF CONSTRUCTION.
M. ALL CONCEALED WOOD SHALL BE FIRE RETARDANT TREATED.
N. SEAL CONSTRUCTION TIGHT TO ALL PENETRATIONS AND APPLY SEALANT.
O. ALL PENETRATIONS THROUGH FIRE RATED CONSTRUCTION MUST BE FIRE SAFE'D IN ACCORDANCE WITH
THE SPECIFICATIONS. IF FLOOR OR RATED WALL PENETRATIONS CANNOT BE FIRESTOPPED AT THE END
OF THE WORK SHIFT DUE TO THE NEED TO PULL ADDITIONAL CABLES, TEMPORARY FIRESTOPPING
COMPOSED OF MINERAL WOOL SHOULD BE INSTALLED IN THE PENETRATION TO PROVIDE PROTECTION
AGAINST FIRE/SMOKE SPREAD THROUGH THE UNSEALED PENETRATION.
P. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL EQUIPMENT INSTALLATION AND VERIFYING
ALL REQUIRED ROUGH OPENINGS, AND ROUGH-IN DIMENSIONS WITH THE EQUIPMENT MANUFACTURER, AND C.O.R. PRIOR TO CONSTRUCTION.
Q. REFER TO SHEET AE601 FOR SCHEDULES AND PARTITION TYPES.
N E W W O R K:
SHEET NAMING EXAMPLE:
BUILDING NUMBER
DISCIPLINE
SHEET TYPE
FLOOR NUMBER
ZONE LOCATION ON FLOOR
100-AE101.1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:3
:3
P
M
GI000.3
COVER SHEET - VOL. 3
07/07/2023 PQ JF
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
BID DOCUMENTS - 100%
CAMPUS
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
N.T.S.Scale:
VICINITY MAP
No. Revisions: Date:
BID DOCUMENTS 07/07/2023
SHEET INDEX
ARCHITECTURE
001-AE100 OVERALL BASMENT FLOOR PLAN
001-AE100.1 BASEMENT FLOOR PLAN - ZONE 1
001-AE101 OVERALL FIRST FLOOR PLAN
001-AE101.1 FIRST FLOOR PLAN - ZONE 1
001-AE101.2 FIRST FLOOR PLAN - ZONE 2
001-AE102 OVERALL SECOND FLOOR PLAN
001-AE102.1 SECOND FLOOR PLAN - ZONE 1
001-AE102.2 SECOND FLOOR PLAN - ZONE 2
003-AE101 OVERALL FIRST FLOOR PLAN
003-AE101.1 FIRST FLOOR PLAN - ZONE 1
007-AE101 OVERALL FIRST FLOOR PLAN
009-AE101 OVERALL FIRST FLOOR PLAN
018-AE101 OVERALL FIRST FLOOR PLAN
018-AE102 OVERALL SECOND FLOOR PLAN
020-AE102 OVERALL FLOOR PLANS
021-AE101 FIRST FLOOR PLAN
023-AE101 OVERALL FIRST FLOOR
024-AE100 OVERALL BASEMENT FLOOR PLAN
024-AE100.1 BASEMENT TR PLANS
024-AE101 OVERALL FIRST FLOOR PLAN
024-AE101.1 FIRST FLOOR ZONE 1 - TR PLANS
024-AE102 OVERALL SECOND FLOOR PLAN
024-AE102.1 SECOND FLOOR PLAN - TR PLANS
025-AE100 OVERALL FLOOR PLAN
026-AE100 OVERALL BASEMENT FLOOR PLAN
026-AE100.1 BASEMENT FLOOR PLAN - TR PLANS
026-AE101 OVERALL FIRST FLOOR PLAN
026-AE101.1 FIRST FLOOR PLAN - TR PLANS
026-AE102 OVERALL SECOND FLOOR PLAN
026-AE102.1 SECOND FLOOR PLAN - TR PLANS
027-AE100 OVERALL BASEMENT FLOOR PLAN
027-AE100.1 BASEMENT FLOOR ZONE 1 - TR PLANS
027-AE101 OVERALL FIRST FLOOR PLAN
027-AE101.1 FIRST FLOOR ZONE 1 - TR PLANS
027-AE102 OVERALL SECOND FLOOR PLAN
027-AE102.1 SECOND FLOOR ZONE 1 - TR PLANS
028-AE102 OVERALL SECOND FLOOR
030-AE100 OVERALL BASEMENT FLOOR PLAN
030-AE100.1 BASEMENT FLOOR PLAN - ZONE 1
030-AE101 OVERALL FIRST FLOOR PLAN
030-AE101.1 FIRST FLOOR PLAN - TR PLANS
030-AE102 OVERALL SECOND FLOOR PLAN
030-AE102.1 SECOND FLOOR PLAN - TR PLANS
N.T.S.Scale:
VICINITY MAP
SHEET INDEX
GENERAL
GI000.3 COVER SHEET - VOL. 3
UP UP
DN
ZONE 1
ZONE 3ZONE 2
ZONE 5ZONE 4
001-AE100.1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:0
:1
P
M
001-AE100
OVERALL BASMENT FLOOR PLAN
07/07/2023 PQ JF
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
BID DOCUMENTS - 100%
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
N
1" = 10'-0"
B01 - BASEMENT FLOOR PLAN - OVERALL
No. Revisions: Date:
BID DOCUMENTS 07/07/2023
K
001-AE100.1
Training Room
BB103
Game Room
BC100A
Storage
BB102
TELECOMM. ROOM
BB105
Cio Equipment Storage
BB101
Stair
S1-0
Corridor
CB6
Corridor
CB5
Engineering Room
BB104
Mechanical
BB106
Tele Clos
BB104A
Toilet
BB107
Corridor
CB4
Stair
S2-0Storage
BB100
Corridor
CB1
Storage
BB101A
2 - 5
TELECOMM. ROOM
BB105
BB105
TELECOMM. ROOM
BB105
128 SF
TELECOMM. ROOM
BB105
BB105
TELECOMM. ROOM
BB105
A. CONTRACTOR TO DISPOSE OF CONSTRUCTION DEMOLITION DEBRIS.
B. REMOVE ALL CONSTRUCTION DEMOLITION DEBRIS ON DAILY BASIS.
G E N E R A L D E M O L I T I O N N O T E S
G E N E R A L C O N S T R U C T I O N N O T E S
A. REFER TO NEW WORK ARCHITECTURAL FLOOR PLANS FOR PARTITION TYPE DESIGNATIONS. SEE PARTITION TYPES ON
SHEET AE601.
B. ALL GYPSUM BOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.
C. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED OTHERWISE. WHERE PARTITIONS OF DIFFERENT THICKNESSES MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE
FACES ARE STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.
D. ALL COLD-FORMED STEEL FRAMING SHALL BE 20 GUAGE OR HEAVIER.
E. EDGES OF GYPSUM BOARD LEFT EXPOSED TO VIEW, OR ABUTTING DISSIMILAR MATERIAL, IS TO BE FINISHED WITH METAL "L"
BEAD TRIM AND COMPOUND UNLESS NOTED OTHERWISE.
F. ALL FIRE RATED WALL AND FLOOR PENETRATION MUST COMPLY WITH ASTM-E814
G. ALL DOOR OPENINGS SHALL BE 4" FROM A PERPENDICULAR PARTITION TO OUTSIDE FACE OF FRAME, UNLESS NOTED OR
DETAILED OTHERWISE.
H. ALL PARTITIONS, INCL. STUDS, BOARD, ETC. SHALL EXTEND FROM TOP OF FLOOR SLAB TO UNDERSIDE OF CONCRETE SLAB
ABOVE UNLESS OTHERWISE NOTED.
I. CONTRACTOR SHALL CLOSE OFF ANY VOIDS LEFT AS A RESULT OF ANY REMOVALS AND NEW CONSTRUCTION, AS WELL AS INFILL ANY EXISTING VOIDS IN NEWLY DESIGNATED FIRE RATED PARTITIONS. ALL PATCHES SHALL MATCH AND ALIGN WITH
SURROUNDING MATERIALS AND SHALL BE IN ACCORDANCE WITH NFPA CODE.
J. CONTRACTOR SHALL SEAL AROUND ALL M.E.P. PENETRATIONS OR OPENINGS, RESULTING FROM M.E.P. INSTALLATIONS INCLUDING BUT NOT LIMITED TO THE SLAB AND PARTITION WALLS ABOVE AND BELOW CEILINGS.
K. NO EXISTING FIREPROOFING IS TO BE REMOVED FROM EXISTING BUILDING STRUCTURE FOR ANY NEW INSTALLATION FOR
ANY REASON.
L. LABEL ALL RATED PARTITIONS (FIRE & SMOKE) ABOVE THE CEILING, ON BOTH SIDES OF THE WALL.
M. PROVIDE A MINIMUM OF ONE STUD SEPARATION BETWEEN OUTLET BOXES AND OTHER PENETRATIONS OCCURRING AT
OPPOSITE FACE OF WALLS.
N. PROVIDE CONTINUOUS NON-HARDENING ACOUSTICAL SEALANT AT TOP, SIDES AND EDGES OF BOTH SIDES OF WALL AT ALL NON-RATED GYPSUM BOARD PARTITIONS SCHEDULED TO RECEIVE SOUND ATTENUATION BLANKETS.
O. ALL PENETRATIONS AT NON-RATED WALLS SHALL BE SLEEVED AND PACKED AIRTIGHT WITH SAFING INSULATION AND SEALANT. ALL JOINT OF GYPSUM BOARD PANELS SHALL BE STAGGERED, TAPED, AND SEALED. FRAMING TO 1/2" +/-
CLEARANCE AT PERIMETER OF MECHANICAL DUCTWORK.
P. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER
MANUFACTURER'S WRITTEN INSTRUCTIONS.
Q. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.
R. PROVIDE DOUBLE CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.
S. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER
REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.
T. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
U. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
V. BUILD PARTITIONS IN ACCORDANCE WITH PARTITION TYPE AND DESIGN REFERENCED. REFERENCES ARE TO LATEST EDITION OF GYPSUM ASSOCIATION (GA) FIRE RESISTANCE DESIGN MANUAL, OR TO UNDERWRITERS LABORATORY (UL) FIRE
RESISTANCE DIRECTORY.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:0
:2
P
M
001-AE100.1
BASEMENT FLOOR PLAN - ZONE 1
07/07/2023 PQ JF
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
BID DOCUMENTS - 100%
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
1/8" = 1'-0"
B01 - BASEMENT FLOOR PLAN - ZONE 1
1/4" = 1'-0"
B01 - BASEMENT FLOOR PLAN - DEMO
1/4" = 1'-0"
B01 - BASEMENT REFLECTED CEILING PLAN - DEMO
1/4" = 1'-0"
B01 - BASEMENT FLOOR PLAN - NEW WORK
1/4" = 1'-0"
B01 - BASEMENT REFLECTED CEILING PLAN - NEW WORK
D R A W I N G N O T E S :
1 REMOVE EXISTING DOOR FRAME, DOOR, AND HARDWARE; TURN DOOR AND HARDWARE OVER TO VA TO ADD TO
EXISTING STOCK.
2 REMOVE EXISTING CARPET AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR INSTALLATION OF
ELECTROSTATIC DISSIPATING (ESD) EPOXY FLOOR PAINT.
3 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND CONDUIT.
PAINT WHITE ALL BUT FIRE RATING LABEL.
4 EXISTING WALL MOUNTED PLYWOOD TO REMAIN, TYPICAL.
5 ELECTROSTATIC DISSIPATING (ESD) EPOXY FLOOR PAINT - SEE HATCHED AREA.
6 WINDOW SECURITY BARS - REFER TO DETAILS ON SHEET AE601 FOR BASIS OF DESIGN AND DETAILS.
7 REMOVE VINYL WALL BASE ALONG THIS WALL.
8 VINYL WALL BASE ALONG WALL, MATCH EXISTING BASE IN ROOM.
9 WALL MOUNTED FIRE EXTINGUISHER CABINET. PROVIDE NEW 10LB. CLASS C FIRE EXTINGUISHER FOR CABINET. SEE
FIRE CABINET ELEVATION ON SHEET GI001 FOR INSTALLATION HEIGHT.
10 REMOVE ALL PAINT AND DEBRIS FROM WALL. AREA IDENTIFIED BY DASHED LINE.
11 PAINT WALLS - REFER TO FINISH SCHEDULE
12 NO CEILING IN THIS AREA
13 REMOVE CEILING SYSTEMS AND SUPPORTS
14 EXISTING CARD READER TO REMAIN
15 NEW WALL - REFER TO AE601 FOR PARTITION TYPE DETAIL.
DN DNDN
ZONE 1
ZONE 3ZONE 2
ZONE 5ZONE 4
001-AE101.1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:0
:3
P
M
001-AE101
OVERALL FIRST FLOOR PLAN
07/07/2023 PQ JF
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
BID DOCUMENTS - 100%
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
1" = 10'-0"
B01 - FIRST FLOOR PLAN - OVERALL
UP
KToilet
Voucher Examiner & Employee Travel
Conference Room
Contract Specialist
Contract Spec Intern
Supply Tech
Chief Acquisitions/ Contracting
Contract Liason
Contract Specialist
Contract Specialists
Admin Support Assist
Chief Logistics
Chief Inventory Supply Support
Inventory Management Spec
Item Manager
Item Manager
Item Manager
Xerox/supplies
Toilet
Files Storage
TR
Corridor
1C002
Corridor
1C006
Stair
S1-1
001-AE101.2
22 - 5
A. CONTRACTOR TO DISPOSE OF CONSTRUCTION DEMOLITION DEBRIS.
B. REMOVE ALL CONSTRUCTION DEMOLITION DEBRIS ON DAILY BASIS.
G E N E R A L D E M O L I T I O N N O T E S
G E N E R A L C O N S T R U C T I O N N O T E S
A. REFER TO NEW WORK ARCHITECTURAL FLOOR PLANS FOR PARTITION TYPE DESIGNATIONS. SEE PARTITION TYPES ON
SHEET AE601.
B. ALL GYPSUM BOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.
C. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED OTHERWISE. WHERE PARTITIONS OF DIFFERENT THICKNESSES MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE
FACES ARE STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.
D. ALL COLD-FORMED STEEL FRAMING SHALL BE 20 GUAGE OR HEAVIER.
E. EDGES OF GYPSUM BOARD LEFT EXPOSED TO VIEW, OR ABUTTING DISSIMILAR MATERIAL, IS TO BE FINISHED WITH METAL "L"
BEAD TRIM AND COMPOUND UNLESS NOTED OTHERWISE.
F. ALL FIRE RATED WALL AND FLOOR PENETRATION MUST COMPLY WITH ASTM-E814
G. ALL DOOR OPENINGS SHALL BE 4" FROM A PERPENDICULAR PARTITION TO OUTSIDE FACE OF FRAME, UNLESS NOTED OR
DETAILED OTHERWISE.
H. ALL PARTITIONS, INCL. STUDS, BOARD, ETC. SHALL EXTEND FROM TOP OF FLOOR SLAB TO UNDERSIDE OF CONCRETE SLAB
ABOVE UNLESS OTHERWISE NOTED.
I. CONTRACTOR SHALL CLOSE OFF ANY VOIDS LEFT AS A RESULT OF ANY REMOVALS AND NEW CONSTRUCTION, AS WELL AS INFILL ANY EXISTING VOIDS IN NEWLY DESIGNATED FIRE RATED PARTITIONS. ALL PATCHES SHALL MATCH AND ALIGN WITH
SURROUNDING MATERIALS AND SHALL BE IN ACCORDANCE WITH NFPA CODE.
J. CONTRACTOR SHALL SEAL AROUND ALL M.E.P. PENETRATIONS OR OPENINGS, RESULTING FROM M.E.P. INSTALLATIONS INCLUDING BUT NOT LIMITED TO THE SLAB AND PARTITION WALLS ABOVE AND BELOW CEILINGS.
K. NO EXISTING FIREPROOFING IS TO BE REMOVED FROM EXISTING BUILDING STRUCTURE FOR ANY NEW INSTALLATION FOR
ANY REASON.
L. LABEL ALL RATED PARTITIONS (FIRE & SMOKE) ABOVE THE CEILING, ON BOTH SIDES OF THE WALL.
M. PROVIDE A MINIMUM OF ONE STUD SEPARATION BETWEEN OUTLET BOXES AND OTHER PENETRATIONS OCCURRING AT
OPPOSITE FACE OF WALLS.
N. PROVIDE CONTINUOUS NON-HARDENING ACOUSTICAL SEALANT AT TOP, SIDES AND EDGES OF BOTH SIDES OF WALL AT ALL NON-RATED GYPSUM BOARD PARTITIONS SCHEDULED TO RECEIVE SOUND ATTENUATION BLANKETS.
O. ALL PENETRATIONS AT NON-RATED WALLS SHALL BE SLEEVED AND PACKED AIRTIGHT WITH SAFING INSULATION AND SEALANT. ALL JOINT OF GYPSUM BOARD PANELS SHALL BE STAGGERED, TAPED, AND SEALED. FRAMING TO 1/2" +/-
CLEARANCE AT PERIMETER OF MECHANICAL DUCTWORK.
P. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER
MANUFACTURER'S WRITTEN INSTRUCTIONS.
Q. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.
R. PROVIDE DOUBLE CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.
S. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER
REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.
T. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
U. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
V. BUILD PARTITIONS IN ACCORDANCE WITH PARTITION TYPE AND DESIGN REFERENCED. REFERENCES ARE TO LATEST EDITION OF GYPSUM ASSOCIATION (GA) FIRE RESISTANCE DESIGN MANUAL, OR TO UNDERWRITERS LABORATORY (UL) FIRE
RESISTANCE DIRECTORY.
Files Storage
TR
Files Storage
98 SF
TR
5 6
8 9
Files Storage
98 SF
TR
TR
Files Storage
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:0
:5
P
M
001-AE101.2
FIRST FLOOR PLAN - ZONE 2
07/07/2023 Checker Author
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
BID DOCUMENTS - 100%
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
1/8" = 1'-0"
B01 - FIRST FLOOR PLAN - ZONE 2
D R A W I N G N O T E S :
1 REMOVE WALL
2 NO CEILING IN THIS AREA
3 WALL MOUNTED FIRE EXTINGUISHER CABINET. PROVIDE NEW 10LB. CLASS C FIRE EXTINGUISHER FOR CABINET. SEE
FIRE CABINET ELEVATION ON SHEET GI001 FOR INSTALLATION HEIGHT.
4 ELECTROSTATIC DISSIPATING (ESD) EPOXY FLOOR PAINT - SEE HATCHED AREA.
5 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND CONDUIT.
PAINT WHITE ALL BUT FIRE RATING LABEL.
6 WINDOW SECURITY BARS - REFER TO DETAILS ON SHEET AE601 FOR BASIS OF DESIGN AND DETAILS.
7 REMOVE CEILING GRID AND ACOUSTICAL TILES. LEAVE CEILING GRID SUPPORTS FOR INSTALLATION OF NEW GRID AND
TILES.
8 PAINT WALLS - REFER TO FINISH SCHEDULE
9 VINYL WALL BASE ALONG WALL - MATCH EXISTING BASE IN ROOM.
10 NEW CEILING COMPONENTS TO TIE EXISTING CEILING SYSTEM TO NEW WALL - MATCH EXISTING GRID COMPONENTS
AND ACOUSTICAL CEILING TILES
11 EXISTING CARD READER TO REMAIN
12 NEW WALL - REFER TO AE601 FOR PARTITION TYPE DETAIL.
1/4" = 1'-0"
B01 - FIRST FLOOR PLAN - DEMO
1/4" = 1'-0"
B01 - FIRST FLOOR PLAN - NEW WORK
1/4" = 1'-0"
B01 - FIRST FLOOR REFLECTED CEILING PLAN - NEW WORK
1/4" = 1'-0"
B01 - FIRST FLOOR REFLECTED CEILING PLAN - DEMO
DN DNDN
001-AE101.1
Risk Manager
Performance Measure Coordinator
Patient Safety
External Review Manager
Contracting Liason Office
Toilet
Filing Supplies
Utilization Nurse
HAC
Performance Measure Coordinator
Program Support Assistant
Systems Design Coordinator
HAC
Copy Room
Break Room
Quality Improvement Facilitator
Quality Manager
QI Program Asst
Waiting
1L001
Corridor
1C002
Waiting
1L002
Corridor
1C007
Stair
S2-1
Stair
S1-1
2 - 5
Eeo Manage
Eeo Manage
116 SF
TR
1L002
Eeo Manage
TR
A. CONTRACTOR TO DISPOSE OF CONSTRUCTION DEMOLITION DEBRIS.
B. REMOVE ALL CONSTRUCTION DEMOLITION DEBRIS ON DAILY BASIS.
G E N E R A L D E M O L I T I O N N O T E S
G E N E R A L C O N S T R U C T I O N N O T E S
A. REFER TO NEW WORK ARCHITECTURAL FLOOR PLANS FOR PARTITION TYPE DESIGNATIONS. SEE PARTITION TYPES ON
SHEET AE601.
B. ALL GYPSUM BOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.
C. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED OTHERWISE. WHERE PARTITIONS OF DIFFERENT THICKNESSES MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE
FACES ARE STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.
D. ALL COLD-FORMED STEEL FRAMING SHALL BE 20 GUAGE OR HEAVIER.
E. EDGES OF GYPSUM BOARD LEFT EXPOSED TO VIEW, OR ABUTTING DISSIMILAR MATERIAL, IS TO BE FINISHED WITH METAL "L"
BEAD TRIM AND COMPOUND UNLESS NOTED OTHERWISE.
F. ALL FIRE RATED WALL AND FLOOR PENETRATION MUST COMPLY WITH ASTM-E814
G. ALL DOOR OPENINGS SHALL BE 4" FROM A PERPENDICULAR PARTITION TO OUTSIDE FACE OF FRAME, UNLESS NOTED OR
DETAILED OTHERWISE.
H. ALL PARTITIONS, INCL. STUDS, BOARD, ETC. SHALL EXTEND FROM TOP OF FLOOR SLAB TO UNDERSIDE OF CONCRETE SLAB
ABOVE UNLESS OTHERWISE NOTED.
I. CONTRACTOR SHALL CLOSE OFF ANY VOIDS LEFT AS A RESULT OF ANY REMOVALS AND NEW CONSTRUCTION, AS WELL AS INFILL ANY EXISTING VOIDS IN NEWLY DESIGNATED FIRE RATED PARTITIONS. ALL PATCHES SHALL MATCH AND ALIGN WITH
SURROUNDING MATERIALS AND SHALL BE IN ACCORDANCE WITH NFPA CODE.
J. CONTRACTOR SHALL SEAL AROUND ALL M.E.P. PENETRATIONS OR OPENINGS, RESULTING FROM M.E.P. INSTALLATIONS INCLUDING BUT NOT LIMITED TO THE SLAB AND PARTITION WALLS ABOVE AND BELOW CEILINGS.
K. NO EXISTING FIREPROOFING IS TO BE REMOVED FROM EXISTING BUILDING STRUCTURE FOR ANY NEW INSTALLATION FOR
ANY REASON.
L. LABEL ALL RATED PARTITIONS (FIRE & SMOKE) ABOVE THE CEILING, ON BOTH SIDES OF THE WALL.
M. PROVIDE A MINIMUM OF ONE STUD SEPARATION BETWEEN OUTLET BOXES AND OTHER PENETRATIONS OCCURRING AT
OPPOSITE FACE OF WALLS.
N. PROVIDE CONTINUOUS NON-HARDENING ACOUSTICAL SEALANT AT TOP, SIDES AND EDGES OF BOTH SIDES OF WALL AT ALL NON-RATED GYPSUM BOARD PARTITIONS SCHEDULED TO RECEIVE SOUND ATTENUATION BLANKETS.
O. ALL PENETRATIONS AT NON-RATED WALLS SHALL BE SLEEVED AND PACKED AIRTIGHT WITH SAFING INSULATION AND SEALANT. ALL JOINT OF GYPSUM BOARD PANELS SHALL BE STAGGERED, TAPED, AND SEALED. FRAMING TO 1/2" +/-
CLEARANCE AT PERIMETER OF MECHANICAL DUCTWORK.
P. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER
MANUFACTURER'S WRITTEN INSTRUCTIONS.
Q. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.
R. PROVIDE DOUBLE CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.
S. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER
REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.
T. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
U. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
V. BUILD PARTITIONS IN ACCORDANCE WITH PARTITION TYPE AND DESIGN REFERENCED. REFERENCES ARE TO LATEST EDITION OF GYPSUM ASSOCIATION (GA) FIRE RESISTANCE DESIGN MANUAL, OR TO UNDERWRITERS LABORATORY (UL) FIRE
RESISTANCE DIRECTORY.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:0
:4
P
M
001-AE101.1
FIRST FLOOR PLAN - ZONE 1
07/07/2023 PQ JF
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
BID DOCUMENTS - 100%
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
1/8" = 1'-0"
B01 - FIRST FLOOR PLAN - ZONE 1
1/4" = 1'-0"
B01 - FIRST FLOOR PLAN - DEMO
1/4" = 1'-0"
B01 - FIRST FLOOR PLAN - NEW WORK
D R A W I N G N O T E S :
1 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND CONDUIT.
PAINT WHITE ALL BUT FIRE RATING LABEL.
2 REMOVE EXISTING CARPET AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR INSTALLATION OF
ELECTROSTATIC DISSIPATING (ESD) EPOXY FLOOR PAINT.
3 REMOVE CEILING SYSTEMS AND SUPPORTS
4 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND CONDUIT.
PAINT WHITE ALL BUT FIRE RATING LABEL.
5 ELECTROSTATIC DISSIPATING (ESD) EPOXY FLOOR PAINT - SEE HATCHED AREA.
6 WINDOW SECURITY BARS - REFER TO DETAILS ON SHEET AE601 FOR BASIS OF DESIGN AND DETAILS.
7 NO CEILING IN THIS AREA
8 REMOVED AND REPLACE FRAME AND LOCK SET AS REQUIRED FOR CARD READER. REUSE REMAINING HARDWARE
9 WALL MOUNTED FIRE EXTINGUISHER CABINET. PROVIDE NEW 10LB. CLASS C FIRE EXTINGUISHER FOR CABINET. SEE
FIRE CABINET ELEVATION ON SHEET GI001 FOR INSTALLATION HEIGHT.
10 REMOVE PACKAGED THERMAL UNIT
11 CARD READER - REFER TO ELECTRICAL DRAWINGS1/4" = 1'-0"
B01 - FIRST FLOOR REFLECTED CEILING PLAN - DEMO
1/4" = 1'-0"
B01 - FIRST FLOOR REFLECTED CEILING PLAN - NEW WORK
DN
UP
D
EM
D
D
EM
D
EM
D
EM
D
D
D
EM
EM
D
D
D
EM
E M
D
D
E M
D
ZONE 1
ZONE 3ZONE 2
ZONE 5ZONE 4
001-AE102.1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:0
:0
P
M
001-AE102
OVERALL SECOND FLOOR PLAN
07/07/2023 PQ JF
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
BID DOCUMENTS - 100%
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
N
1" = 10'-0"
B01 - SECOND FLOOR PLAN - OVERALL
K
Toilet
Regional Counsel Library
Hr Assistants
Copy/mail Room
Hrm Office
Intern Office
Hrm Office
Resource Room
Hrm Specalists
Vet Pro
Hrm Office
Hrm Office
Hrm Office
Tele Clos
Employee Resources
Regional Counsel Office
224A
Corridor
2C5
Regional Counsel Office
224B
Tele Clos
Stair
S1-2
Corridor
2C003
302 SF
Corridor
2C002
HMR ASSISTANT
238 001-AE102.2
22 - 5
A. CONTRACTOR TO DISPOSE OF CONSTRUCTION DEMOLITION DEBRIS.
B. REMOVE ALL CONSTRUCTION DEMOLITION DEBRIS ON DAILY BASIS.
G E N E R A L D E M O L I T I O N N O T E S
G E N E R A L C O N S T R U C T I O N N O T E S
A. REFER TO NEW WORK ARCHITECTURAL FLOOR PLANS FOR PARTITION TYPE DESIGNATIONS. SEE PARTITION TYPES ON
SHEET AE601.
B. ALL GYPSUM BOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.
C. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED OTHERWISE. WHERE PARTITIONS OF DIFFERENT THICKNESSES MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE
FACES ARE STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.
D. ALL COLD-FORMED STEEL FRAMING SHALL BE 20 GUAGE OR HEAVIER.
E. EDGES OF GYPSUM BOARD LEFT EXPOSED TO VIEW, OR ABUTTING DISSIMILAR MATERIAL, IS TO BE FINISHED WITH METAL "L"
BEAD TRIM AND COMPOUND UNLESS NOTED OTHERWISE.
F. ALL FIRE RATED WALL AND FLOOR PENETRATION MUST COMPLY WITH ASTM-E814
G. ALL DOOR OPENINGS SHALL BE 4" FROM A PERPENDICULAR PARTITION TO OUTSIDE FACE OF FRAME, UNLESS NOTED OR
DETAILED OTHERWISE.
H. ALL PARTITIONS, INCL. STUDS, BOARD, ETC. SHALL EXTEND FROM TOP OF FLOOR SLAB TO UNDERSIDE OF CONCRETE SLAB
ABOVE UNLESS OTHERWISE NOTED.
I. CONTRACTOR SHALL CLOSE OFF ANY VOIDS LEFT AS A RESULT OF ANY REMOVALS AND NEW CONSTRUCTION, AS WELL AS INFILL ANY EXISTING VOIDS IN NEWLY DESIGNATED FIRE RATED PARTITIONS. ALL PATCHES SHALL MATCH AND ALIGN WITH
SURROUNDING MATERIALS AND SHALL BE IN ACCORDANCE WITH NFPA CODE.
J. CONTRACTOR SHALL SEAL AROUND ALL M.E.P. PENETRATIONS OR OPENINGS, RESULTING FROM M.E.P. INSTALLATIONS INCLUDING BUT NOT LIMITED TO THE SLAB AND PARTITION WALLS ABOVE AND BELOW CEILINGS.
K. NO EXISTING FIREPROOFING IS TO BE REMOVED FROM EXISTING BUILDING STRUCTURE FOR ANY NEW INSTALLATION FOR
ANY REASON.
L. LABEL ALL RATED PARTITIONS (FIRE & SMOKE) ABOVE THE CEILING, ON BOTH SIDES OF THE WALL.
M. PROVIDE A MINIMUM OF ONE STUD SEPARATION BETWEEN OUTLET BOXES AND OTHER PENETRATIONS OCCURRING AT
OPPOSITE FACE OF WALLS.
N. PROVIDE CONTINUOUS NON-HARDENING ACOUSTICAL SEALANT AT TOP, SIDES AND EDGES OF BOTH SIDES OF WALL AT ALL NON-RATED GYPSUM BOARD PARTITIONS SCHEDULED TO RECEIVE SOUND ATTENUATION BLANKETS.
O. ALL PENETRATIONS AT NON-RATED WALLS SHALL BE SLEEVED AND PACKED AIRTIGHT WITH SAFING INSULATION AND SEALANT. ALL JOINT OF GYPSUM BOARD PANELS SHALL BE STAGGERED, TAPED, AND SEALED. FRAMING TO 1/2" +/-
CLEARANCE AT PERIMETER OF MECHANICAL DUCTWORK.
P. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER
MANUFACTURER'S WRITTEN INSTRUCTIONS.
Q. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.
R. PROVIDE DOUBLE CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.
S. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER
REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.
T. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
U. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
V. BUILD PARTITIONS IN ACCORDANCE WITH PARTITION TYPE AND DESIGN REFERENCED. REFERENCES ARE TO LATEST EDITION OF GYPSUM ASSOCIATION (GA) FIRE RESISTANCE DESIGN MANUAL, OR TO UNDERWRITERS LABORATORY (UL) FIRE
RESISTANCE DIRECTORY.
Tele Clos
HMR ASSISTANT
REMOVE FLOORING BOUNDARY
Tele Clos
HMR ASSISTANT
HMR ASSISTANT
Tele Clos
HMR ASSISTANT
Tele Clos
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:0
:3
P
M
001-AE102.2
SECOND FLOOR PLAN - ZONE 2
07/07/2023 Checker Author
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
BID DOCUMENTS - 100%
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
N
1/8" = 1'-0"
B01 - SECOND FLOOR PLAN - ZONE 2
D R A W I N G N O T E S :
1 REMOVE EXISTING CARPET AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR INSTALLATION OF
ELECTROSTATIC DISSIPATING (ESD) EPOXY FLOOR PAINT.
2 REMOVE WALL
3 NEW WALL - REFER TO AE601 FOR PARTITION TYPE DETAIL.
4 ELECTROSTATIC DISSIPATING (ESD) EPOXY FLOOR PAINT - SEE HATCHED AREA.
5 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND CONDUIT.
PAINT WHITE ALL BUT FIRE RATING LABEL.
6 WINDOW SECURITY BARS - REFER TO DETAILS ON SHEET AE601 FOR BASIS OF DESIGN AND DETAILS.
7 PAINT WALLS - REFER TO FINISH SCHEDULE
8 LEAVE CEILING SUPPORTS IN ADJACENT SPACE TO FUTURE TR. NEW CEILING COMPONENTS TO BE INSTALLED AND TIED
INTO EXISTING CEILING GRID.
9 VINYL WALL BASE ALONG WALL - MATCH EXISTING BASE IN ROOM.
10 WALL MOUNTED FIRE EXTINGUISHER CABINET. PROVIDE NEW 10LB. CLASS C FIRE EXTINGUISHER FOR CABINET. SEE
FIRE CABINET ELEVATION ON SHEET GI001 FOR INSTALLATION HEIGHT.
11 NO CEILING IN THIS AREA
12 NEW CEILING COMPONENTS TO TIE EXISTING CEILING SYSTEM TO NEW WALL - MATCH EXISTING GRID COMPONENTS
AND ACOUSTICAL CEILING TILES
13 EXISTING CARD READER TO REMAIN
1/4" = 1'-0"
B01 - SECOND FLOOR PLAN - DEMO
1/4" = 1'-0"
B01 - SECOND FLOOR PLAN - NEW WORK
1/4" = 1'-0"
B01 - SECOND FLOOR REFLECTED CEILING PLAN - DEMO
1/4" = 1'-0"
B01 - SECOND FLOOR REFLECTED CEILING PLAN - NEW WORK
DN
UP
K
001-AE102.1
22 - 5
Health Systems Spec Pcs
Emergency Preparedness Coordinator
Patient Business Intern
Assistant Patient Business Manager
Customer Service Coordinator
Toilet
Dss Liason
Interior Designer
Conference/Training
Facility Telehealth Coordinator
HAC
Break Room
Training Room
Training Room
Patient Business Service Manager
245A
Heart Code Room
Stair
S1-2
Stair
S2-2
Corridor
2C002
Corridor
2C001 Corridor
2C006
Corridor
2C005
TR
284A
TRAINING ROOM
10' - 5"
R E
M O
V E
F
LO
O
R
IN
G B
O U
N D
A R
Y
TRAINING ROOM
TRAINING ROOM
10' - 0"
TR
284A
284A
11 12
TRAINING ROOM
TRAINING ROOM
A. CONTRACTOR TO DISPOSE OF CONSTRUCTION DEMOLITION DEBRIS.
B. REMOVE ALL CONSTRUCTION DEMOLITION DEBRIS ON DAILY BASIS.
G E N E R A L D E M O L I T I O N N O T E S
G E N E R A L C O N S T R U C T I O N N O T E S
A. REFER TO NEW WORK ARCHITECTURAL FLOOR PLANS FOR PARTITION TYPE DESIGNATIONS. SEE PARTITION TYPES ON
SHEET AE601.
B. ALL GYPSUM BOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.
C. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED OTHERWISE. WHERE PARTITIONS OF DIFFERENT THICKNESSES MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE
FACES ARE STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.
D. ALL COLD-FORMED STEEL FRAMING SHALL BE 20 GUAGE OR HEAVIER.
E. EDGES OF GYPSUM BOARD LEFT EXPOSED TO VIEW, OR ABUTTING DISSIMILAR MATERIAL, IS TO BE FINISHED WITH METAL "L"
BEAD TRIM AND COMPOUND UNLESS NOTED OTHERWISE.
F. ALL FIRE RATED WALL AND FLOOR PENETRATION MUST COMPLY WITH ASTM-E814
G. ALL DOOR OPENINGS SHALL BE 4" FROM A PERPENDICULAR PARTITION TO OUTSIDE FACE OF FRAME, UNLESS NOTED OR
DETAILED OTHERWISE.
H. ALL PARTITIONS, INCL. STUDS, BOARD, ETC. SHALL EXTEND FROM TOP OF FLOOR SLAB TO UNDERSIDE OF CONCRETE SLAB
ABOVE UNLESS OTHERWISE NOTED.
I. CONTRACTOR SHALL CLOSE OFF ANY VOIDS LEFT AS A RESULT OF ANY REMOVALS AND NEW CONSTRUCTION, AS WELL AS INFILL ANY EXISTING VOIDS IN NEWLY DESIGNATED FIRE RATED PARTITIONS. ALL PATCHES SHALL MATCH AND ALIGN WITH
SURROUNDING MATERIALS AND SHALL BE IN ACCORDANCE WITH NFPA CODE.
J. CONTRACTOR SHALL SEAL AROUND ALL M.E.P. PENETRATIONS OR OPENINGS, RESULTING FROM M.E.P. INSTALLATIONS INCLUDING BUT NOT LIMITED TO THE SLAB AND PARTITION WALLS ABOVE AND BELOW CEILINGS.
K. NO EXISTING FIREPROOFING IS TO BE REMOVED FROM EXISTING BUILDING STRUCTURE FOR ANY NEW INSTALLATION FOR
ANY REASON.
L. LABEL ALL RATED PARTITIONS (FIRE & SMOKE) ABOVE THE CEILING, ON BOTH SIDES OF THE WALL.
M. PROVIDE A MINIMUM OF ONE STUD SEPARATION BETWEEN OUTLET BOXES AND OTHER PENETRATIONS OCCURRING AT
OPPOSITE FACE OF WALLS.
N. PROVIDE CONTINUOUS NON-HARDENING ACOUSTICAL SEALANT AT TOP, SIDES AND EDGES OF BOTH SIDES OF WALL AT ALL NON-RATED GYPSUM BOARD PARTITIONS SCHEDULED TO RECEIVE SOUND ATTENUATION BLANKETS.
O. ALL PENETRATIONS AT NON-RATED WALLS SHALL BE SLEEVED AND PACKED AIRTIGHT WITH SAFING INSULATION AND SEALANT. ALL JOINT OF GYPSUM BOARD PANELS SHALL BE STAGGERED, TAPED, AND SEALED. FRAMING TO 1/2" +/-
CLEARANCE AT PERIMETER OF MECHANICAL DUCTWORK.
P. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER
MANUFACTURER'S WRITTEN INSTRUCTIONS.
Q. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.
R. PROVIDE DOUBLE CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.
S. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER
REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.
T. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
U. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
V. BUILD PARTITIONS IN ACCORDANCE WITH PARTITION TYPE AND DESIGN REFERENCED. REFERENCES ARE TO LATEST EDITION OF GYPSUM ASSOCIATION (GA) FIRE RESISTANCE DESIGN MANUAL, OR TO UNDERWRITERS LABORATORY (UL) FIRE
RESISTANCE DIRECTORY.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:0
:2
P
M
001-AE102.1
SECOND FLOOR PLAN - ZONE 1
07/07/2023 PQ JF
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
BID DOCUMENTS - 100%
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
N
1/8" = 1'-0"
B01 - SECOND FLOOR PLAN - ZONE 1
1/4" = 1'-0"
B01 - SECOND FLOOR REFLECTED CEILING PLAN - NEW WORK
1/4" = 1'-0"
B01 - SECOND FLOOR PLAN - DEMO
1/4" = 1'-0"
B01 - SECOND FLOOR PLAN - NEW WORK
1/4" = 1'-0"
B01 - SECOND FLOOR REFLECTED CEILING PLAN - DEMO
D R A W I N G N O T E S :
1 REMOVE EXISTING CARPET AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR INSTALLATION OF
ELECTROSTATIC DISSIPATING (ESD) EPOXY FLOOR PAINT.
2 WINDOW SECURITY BARS - REFER TO DETAILS ON SHEET AE601 FOR BASIS OF DESIGN AND DETAILS.
3 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND CONDUIT.
PAINT WHITE ALL BUT FIRE RATING LABEL.
4 ELECTROSTATIC DISSIPATING (ESD) EPOXY FLOOR PAINT - SEE HATCHED AREA.
5 REMOVE EXISTING DOOR FRAME, DOOR, AND HARDWARE; TURN DOOR AND HARDWARE OVER TO VA TO ADD TO
EXISTING STOCK.
6 LEAVE CEILING SUPPORTS IN ADJACENT SPACE TO FUTURE TR. NEW CEILING COMPONENTS TO BE INSTALLED AND TIED
INTO EXISTING CEILING GRID.
7 NO CEILING IN THIS AREA
8 NEW CEILING COMPONENTS TO TIE EXISTING CEILING SYSTEM TO NEW WALL - MATCH EXISTING GRID COMPONENTS
AND ACOUSTICAL CEILING TILES
9 NEW WALL - REFER TO AE601 FOR PARTITION TYPE DETAIL.
10 VINYL WALL BASE ALONG WALL - MATCH EXISTING BASE IN ROOM.
11 WALL MOUNTED FIRE EXTINGUISHER CABINET. PROVIDE NEW 10LB. CLASS C FIRE EXTINGUISHER FOR CABINET. SEE
FIRE CABINET ELEVATION ON SHEET GI001 FOR INSTALLATION HEIGHT.
12 CARD READER - REFER TO ELECTRICAL DRAWINGS
13 PAINT WALLS - REFER TO FINISH SCHEDULE
ZONE 1
ZONE 2
ZONE 4 ZONE 5
ZONE 3
003-AE101.1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:0
:4
P
M
003-AE101
OVERALL FIRST FLOOR PLAN
07/07/2023 PQ JF
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
BID DOCUMENTS - 100%
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
N
1" = 10'-0"
B03 - FIRST FLOOR PLAN - OVERALL
003-AE101.1
Supply
106C
HAC
106E
Toilet
106F
Toilet
106G
Corridor
C1-3
Corridor
C1-1
Vet Rep
107A
Day Treatment Office
Program Assistant
Forms Storage
110A
Elect. Room
111A
Toilet
Office
Incentive Therapy
Vestibule
Office
100G
Office
100E
Office
100F
Stair
S2-1
Stair
S1-1
Elect. Room
100A
Office
100H
Office
100D
Supply
100B
Office
100C
Corridor
Existing Dark Room
106A
Waiting
Corridor
106B
Veteran's Industries Marketing
Corridor
C1-2
2 - 5
TELE. CLOSET
TELE CLOSET
TR
TELE. CLOSET
TR
A. CONTRACTOR TO DISPOSE OF CONSTRUCTION DEMOLITION DEBRIS.
B. REMOVE ALL CONSTRUCTION DEMOLITION DEBRIS ON DAILY BASIS.
G E N E R A L D E M O L I T I O N N O T E S
G E N E R A L C O N S T R U C T I O N N O T E S
A. REFER TO NEW WORK ARCHITECTURAL FLOOR PLANS FOR PARTITION TYPE DESIGNATIONS. SEE PARTITION TYPES ON
SHEET AE601.
B. ALL GYPSUM BOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.
C. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED OTHERWISE. WHERE PARTITIONS OF DIFFERENT THICKNESSES MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE
FACES ARE STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.
D. ALL COLD-FORMED STEEL FRAMING SHALL BE 20 GUAGE OR HEAVIER.
E. EDGES OF GYPSUM BOARD LEFT EXPOSED TO VIEW, OR ABUTTING DISSIMILAR MATERIAL, IS TO BE FINISHED WITH METAL "L"
BEAD TRIM AND COMPOUND UNLESS NOTED OTHERWISE.
F. ALL FIRE RATED WALL AND FLOOR PENETRATION MUST COMPLY WITH ASTM-E814
G. ALL DOOR OPENINGS SHALL BE 4" FROM A PERPENDICULAR PARTITION TO OUTSIDE FACE OF FRAME, UNLESS NOTED OR
DETAILED OTHERWISE.
H. ALL PARTITIONS, INCL. STUDS, BOARD, ETC. SHALL EXTEND FROM TOP OF FLOOR SLAB TO UNDERSIDE OF CONCRETE SLAB
ABOVE UNLESS OTHERWISE NOTED.
I. CONTRACTOR SHALL CLOSE OFF ANY VOIDS LEFT AS A RESULT OF ANY REMOVALS AND NEW CONSTRUCTION, AS WELL AS INFILL ANY EXISTING VOIDS IN NEWLY DESIGNATED FIRE RATED PARTITIONS. ALL PATCHES SHALL MATCH AND ALIGN WITH
SURROUNDING MATERIALS AND SHALL BE IN ACCORDANCE WITH NFPA CODE.
J. CONTRACTOR SHALL SEAL AROUND ALL M.E.P. PENETRATIONS OR OPENINGS, RESULTING FROM M.E.P. INSTALLATIONS INCLUDING BUT NOT LIMITED TO THE SLAB AND PARTITION WALLS ABOVE AND BELOW CEILINGS.
K. NO EXISTING FIREPROOFING IS TO BE REMOVED FROM EXISTING BUILDING STRUCTURE FOR ANY NEW INSTALLATION FOR
ANY REASON.
L. LABEL ALL RATED PARTITIONS (FIRE & SMOKE) ABOVE THE CEILING, ON BOTH SIDES OF THE WALL.
M. PROVIDE A MINIMUM OF ONE STUD SEPARATION BETWEEN OUTLET BOXES AND OTHER PENETRATIONS OCCURRING AT
OPPOSITE FACE OF WALLS.
N. PROVIDE CONTINUOUS NON-HARDENING ACOUSTICAL SEALANT AT TOP, SIDES AND EDGES OF BOTH SIDES OF WALL AT ALL NON-RATED GYPSUM BOARD PARTITIONS SCHEDULED TO RECEIVE SOUND ATTENUATION BLANKETS.
O. ALL PENETRATIONS AT NON-RATED WALLS SHALL BE SLEEVED AND PACKED AIRTIGHT WITH SAFING INSULATION AND SEALANT. ALL JOINT OF GYPSUM BOARD PANELS SHALL BE STAGGERED, TAPED, AND SEALED. FRAMING TO 1/2" +/-
CLEARANCE AT PERIMETER OF MECHANICAL DUCTWORK.
P. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER
MANUFACTURER'S WRITTEN INSTRUCTIONS.
Q. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.
R. PROVIDE DOUBLE CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.
S. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER
REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.
T. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
U. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
V. BUILD PARTITIONS IN ACCORDANCE WITH PARTITION TYPE AND DESIGN REFERENCED. REFERENCES ARE TO LATEST EDITION OF GYPSUM ASSOCIATION (GA) FIRE RESISTANCE DESIGN MANUAL, OR TO UNDERWRITERS LABORATORY (UL) FIRE
RESISTANCE DIRECTORY.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:0
:5
P
M
003-AE101.1
FIRST FLOOR PLAN - ZONE 1
07/07/2023 PQ JF
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
BID DOCUMENTS - 100%
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
N
1/8" = 1'-0"
B03 - FIRST FLOOR PLAN - ZONE 1
1/4" = 1'-0"
B03 - FIRST FLOOR PLAN - DEMO
1/4" = 1'-0"
B03 - FIRST FLOOR PLAN - NEW WORK
1/4" = 1'-0"
B03 - FIRST FLOOR REFLECTED CEILING PLAN - DEMO
1/4" = 1'-0"
B03 - FIRST FLOOR REFLECTED CEILING PLAN - NEW WORK
D R A W I N G N O T E S :
1 REMOVE EXISTING CARPET AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR INSTALLATION OF
ELECTROSTATIC DISSIPATING (ESD) EPOXY FLOOR PAINT.
2 REMOVE CEILING SYSTEMS AND SUPPORTS
3 ELECTROSTATIC DISSIPATING (ESD) EPOXY FLOOR PAINT - SEE HATCHED AREA.
4 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND CONDUIT.
PAINT WHITE ALL BUT FIRE RATING LABEL.
5 WINDOW SECURITY BARS - REFER TO DETAILS ON SHEET AE601 FOR BASIS OF DESIGN AND DETAILS.
6 NO CEILING IN THIS AREA
7 WALL MOUNTED FIRE EXTINGUISHER CABINET. PROVIDE NEW 10LB. CLASS C FIRE EXTINGUISHER FOR CABINET. SEE
FIRE CABINET ELEVATION ON SHEET GI001 FOR INSTALLATION HEIGHT.
8 EXISTING CARD READER TO REMAIN
Uniform/PAP Work Room
108K2
PAP Storage
108K3
Toilet
108K4
PAP Storage
108K1
Uniform Drop-off
108K
Toilet
108J
Vestibule
108V2
Corridor
108L
Serving Line/Dining Area
Chief Dietetics
106A
Vestibule
108V1
Dietetics Secretary
106B
Conference Room
Mechanical
106H
Entry
106I
Delivery/Entry
105B
Cart Room
Office
106E
Office
106F
Office
106G Office
106D
HAC
105A
Elect. Room
107A
Toilet
106C
Tele Clos
106K
Closet
106J
Kitchen
104A
Kitchen
Supervisor's Office
Stair 2
S-2-1
Office
Toilet
Freezer
Corridor
Entry Corridor
HAC
115A
Mechanical
109A
Freezer
Dishwashing
109Toilet
Toilet
Vestibule
108V4
Tray Line Assembly
108C
Corridor
109D
HAC
109B Dishwashing
Dietician Office
108F
Toilet
108A
Toilet
108B
TR
108D
Soiled Utility
108G Clean Linen
108H
HAC
108E
Ingredient Control
Refrigerator
118BFreezer
118C
Entry
Stair 1
S-1-1
Toilet
120B
Closet
120C
Office
120A
Freezer
118E
Refrigerator
118D
Vestibule
108V3
Office
120D
Mechanical/Generator Room
109CDock
104B
Closet
105C
Corridor
007-AE101
22 - 5
TELE. CLOSET
108D
REMOVE FLOORING BOUNDARY
108D
TR
108D
108E
HAC
108E
1 1
TELE. CLOSET
108D
TR
108D
A. CONTRACTOR TO DISPOSE OF CONSTRUCTION DEMOLITION DEBRIS.
B. REMOVE ALL CONSTRUCTION DEMOLITION DEBRIS ON DAILY BASIS.
G E N E R A L D E M O L I T I O N N O T E S G E N E R A L C O N S T R U C T I O N N O T E S
A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.
B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.
C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED
OTHERWISE.
D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER
MANUFACTURER'S WRITTEN INSTRUCTIONS.
E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE
ACCORDINGLY.
F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED…