S06 - Amendment 0007 Att 3 - 2023-01 AHERA.pdf

PDF 6 MB Posted

Attached to
Y1DA--538-21-701 EHRM Infrastructure Upgrades Construction Chillicothe, OH (VA-23-00066755)
Solicitation number
36C77623B0058
Issued by

About this file

This solicitation is for construction services to upgrade infrastructure at the Chillicothe VA Medical Center in Chillicothe, Ohio. The Department of Veterans Affairs Technology Acquisition Center Austin is seeking proposals to modernize existing electrical, HVAC, and plumbing systems. Offerors must have the capability to perform renovations, repairs, and installations. The period of performance is 270 calendar days from the notice to proceed. Proposals are due by August 15, 2022 and the contract is expected to be awarded by September 30, 2022.

View the file

Other files

File Type Posted
Abstract of offers - Chillicothe Bid Opening 01172024 signed.pdf PDF
S06 - Amendment 0009 Bid Opening.pdf PDF
S06 - Amendment 0008 Extend due date to 01172024.pdf PDF
S06 - 36C77623B0058 0007.pdf PDF
S06 - Amendment 0007 Att 10 - 14.063_024-EP100 - ELECTRICAL PLAN - BASEMENT FLOOR.pdf PDF
S06 - Amendment 0007 Att 13 - 14.116_E616.31 - PANELBOARD SCHEDULES.pdf PDF
S06 - Amendment 0007 Att 4 - Chiillicothe VA Lead Paint Survey Report.pdf PDF
S06 - Amendment 0007 Att 7 - 000-TS100 - CAMPUS TECHNOLOGY SITE PLAN.pdf PDF
S06 - Amendment 0007 Att 6 - 000-TN500 - TECHNOLOGY DETAILS.pdf PDF
S06 - Amendment 0007 Att 11 - 14.077_031-EP100 - ELECTRICAL PLAN - GROUND FLOOR.pdf PDF
S06 - Amendment 0007 Att 16 - 026-TN100 - BASEMENT PLAN -TECHNOLOGY.pdf PDF
S06 - Amendment 0007 Att 14 - 018-TN209 - TECHNOLOGY ENLARGEMENT.pdf PDF
S06 - Amendment 0007 Att 8 - 13.038_030-MD101 - MECHANICAL DEMOLITION PLAN - FIRST FLOOR.pdf PDF
S06 - Amendment 0007 Att 12 - 14.080_035-EP100 - ELECTRICAL PLAN - BASEMENT.pdf PDF
S06 - Amendment 0007 Att 1 Technical questions Round 2 responses.pdf PDF
S06 - Amendment 0007 Att 2 - Final SWP3.pdf PDF
S06 - Amendment 0007 Att 15 - 018-TN210 - TECHNOLOGY ENLARGEMENT.pdf PDF
S06 - Amendment 0007 Att 5 - 000-TN400 - TECHNOLOGY RISER DIAGRAMS.pdf PDF
S06 - Amendment 0007 Att 9 - 14.062_023-EP101 - ELECTRICAL PLAN - FIRST FLOOR.pdf PDF
Amendment 0006 36C77623B0058.pdf PDF
Amendment 0005 36C77623B0058.pdf PDF
Amendment 0005 - Attachment Addendum 1.zip ZIP file
Amendment 0005 - Attachment - Vendor Questions_Responses final.pdf PDF
Amendment 0004 36C77623B0058.pdf PDF
Amendment 0003 36C77623B0058.docx DOCX document
Att 10 Volume 10 - Technology_Combined.pdf PDF
Att 8 Volume 8 - Electrical_Combined.pdf PDF
Att 6 Volume 6 - Mechanical_Combined.pdf PDF
Att 9 Volume 9 - Electrical_Combined.pdf PDF
Att 13 Volume 13 - Fiber_Combined.pdf PDF
Att 4 Volume 4 - Architectural_Combined.pdf PDF
Att 5 Volume 5 - Fire Suppression_Combined.pdf PDF
Att 14 S04 - Site Visit sign in 10-11-2023.pdf PDF
Att 7 Volume 7 - Mechanical_Combined.pdf PDF
Att 12 Volume 12 - Fiber_Combined.pdf PDF
Att 11 Volume 11 - Technology_Combined.pdf PDF
Att 3 Volume 3 - Architectural_Combined.pdf PDF
Att 2 Volume 2 - Civil_Combined (1).pdf PDF
36C77623B0058 0002.docx DOCX document
Att 1 Volume 1 - General and Civil_Combined.pdf PDF
DBA Wage Rates Construction - Ross Cty.pdf PDF
36C77623B0058 0001.docx DOCX document
Attachment 04 - DBA Wage Determination.pdf PDF
Updated _Specifications_Combined.pdf PDF
Attachment 08 - SOW attach Volume 1 Part 3.pdf PDF
Attachment 09 - SOW attach Volume 1 Part 4.pdf PDF
Attachment 04 - Wage Rate Determination - Chillicothe.pdf PDF
Attachment 11 - SOW attach Volume 1 Part 6.pdf PDF
Attachment 19 - SOW attach Volume 3 Part 4.pdf PDF
Attachment 17 - SOW attach Volume 3 Part 2.pdf PDF
Show 40 more

Latest 50 of 65 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS 6-MONTH SURVEILLANCE REPORT

LOCATION:

CHILLICOTHE VA MEDICAL CENTER

17273 STATE ROUTE 104

CHILLICOTHE, OH 45601

CONTRACT NO.: 36C25021D0039

INSPECTION DATE:

JUNE 14, 2023

PRIME CONTRACTOR:

CASTLE HILL ASSOCIATES, LLC

1197 FARNSWORTH RD. – UNIT E

WATERVILLE, OH 43566

567-952-0212

CHILLICOTHE VA MEDICAL CENTER – CHILLICOTHE, OH

JUNE 2023

TABLE OF CONTENTS

1.0 ASBESTOS SURVEILLANCE INSPECTION REPORT

• Table 1 – List of Acronyms

2.0 APPENDICES

Appendix A – Asbestos Quantities and Assessments

Appendix B – Asbestos Location Drawings

Appendix C - Inspector Certifications

1.0 EXECUTIVE SUMMARY

On June 14, 2023, Castle Hill Associates, LLC was contracted by the US Department of Veterans Affairs (VA) to perform a 6-month asbestos surveillance inspection of the occupied buildings at the Chillicothe VA Medical Center in Chillicothe, OH. The survey was performed as part of the VA Contract Number 36C25021D0039. The Performance Work Statement (PWS) issued by the VA defined the scope of work for the asbestos surveillance inspection.

The inspection was conducted by Priscilla Bersee who is licensed by the Ohio EPA as Asbestos Hazard Evaluation Specialist. The project manager was Brett Brumbaugh who is also an Ohio EPA as Asbestos Hazard Evaluation Specialist and Project Designer. There were numerous asbestos surveys, surveillance inspections, and reinspections conducted at the facility and those reports were reviewed and utilized by Castle Hill as part of this reinspection. There were no limitations or exceptions to the PWS for the surveys conducted.

The basis of this inspection was the AHERA Asbestos 3-year Reinspection survey conducted by Castle Hill Associates in December of 2022. The intent of the 6-month surveillance inspection is to determine any changes in condition of the previously identified asbestos containing materials in the facilities. The 6-month reinspection process was originally specified in the US EPA AHERA (Asbestos Hazard Emergency Response Act) regulation which was passed by Congress in 1986.

The regulation was adopted by the US Department of Veteran Affairs by VHA Directive 7714 dated April 14, 2017.

This directive establishes the Veterans Health Administration (VHA) policy on the identification, management, and control of hazards related to asbestos-containing materials (ACM) at Department of Veterans Affairs (VA) facilities. It is the intent of this policy to assist facilities in developing a comprehensive building asbestos survey, Operations and Maintenance (O&M) plan, and local policies that comply with each of the federal regulations listed below. AUTHORITY: Title 38 United States Code 7301(b); 29 Code of Federal Regulations (CFR) 1910.1001; 29 CFR 1926.1101; 40 CFR Part 763, Subpart E; and 40 CFR 61.

As part of this 6-month surveillance inspections, all previously identified asbestos containing materials were observed and their current condition compared to the original inspection. All accessible functional areas in the buildings were surveyed.

2.0 SUMMARY OF INSPECTION FINDINGS

The following buildings were reinspected as part of this project:

BLDG. # BUILDING NAME

1 Director, Chief of Staff, Human Resources

10 Vacant 3

11 Vacant 4

17 Non-Housekeeping Quarters

179 Storage Building

18 CIO, Police and Security

2 Vacant

20 Incinerator Building

207 Residential Garage

21 Engineering

210 Extended Care Unit

211 Echo, EEG, EKG/Holter, KT

212 Administration Offices/Storage

218 Old Z-Lite Building/Storage

219 Electrical Equipment Building

22 Locksmith Building

23 Acquisition, Material Management

24 Geriatrics, Shared Medical Appointments

247 Gymnasium, Pool

25 Laundry Building

252 Chapel

256 Wastewater Treatment Plant

259 Steam Plant

26 Kinesiotherapy, Mental Health

27 GI, Diabetic, OT Clinics, Medical Records, Special

28 Veteran's Canteen Service

29 Hoptel

3 Day Treatment, Vocational Rehabilitation

30 Medical Intensive Care Unit

31 Admissions, Dental Pharmacy

35 Mental Health Offices, Domiciliary

36 Tool Room Building

4 Pickaway Ross CTC Nursing Program

5 Alvis House

6 Vacant 2

60 Meeting House/Museum

7 Main Patient Kitchen

8 Southern Ohio Council – Call Center

9 Recreational Hall, Voluntary Service

T228 Engineering 4

T233 Engineering/Storage

T236 Greenhouse Garage

T38-40 Engineering 5

T41 Engineering 2

T42 Engineering 3

T51/52 Greenhouse

2.1 Changes in the Condition of the Asbestos-Containing Building Materials The following is a summary of the asbestos containing materials, locations, quantities of materials in each inspected building for this project:

Building 1 – Director, Chief of Staff, Human Resources

Asbestos Containing Materials Locations Changes in Condition

Transite cement flat sheets S. wall of basement mechanical room BB104 None

12” floor tile and mastic (most located under carpeting)

Basement, 1st, and 2nd floors None

Building 3 - Day Treatment, Vocational Rehabilitation

Condition

Asbestos contaminated soils under concrete cap Crawl spaces under building

Removed prior to concrete cap installation per report provided by VA 12-22-22, No change 6/14/23

12” floor tile and mastic (most located under carpeting or vinyl plank flooring) 1st Floor

None

White sink undercoating Basement Room 12 Removed per report provided 12-22-22 by VA No change 6/14/23

Building 7 - Main Patient Kitchen

Condition

Black mastic above cork insulation (inaccessible above freezers)

Basement freezers rooms 17, 18, and

Removed per report provided 12-22-22 by VA

Building 8 - Southern Ohio Council

Condition

Asbestos pipe insulation Basement rooms 2, 3, 5, and 6

Removed per report provided by VA 12-22-22 No change 6/14/23

12” floor tile and mastic (most located under carpeting) Only remaining room is 106

Per VA report of 12-22-22

Black residual mastic under carpeting 1st floor None

Building 9 - Recreational Hall, Voluntary Service

Condition

Asbestos pipe insulation Crawl space, Basement, and 1st floor room 103

None

9” and 12” floor tile and mastic Basement None

Building 18 - CIO, Police and Security

Condition

Asbestos pipe insulation Basement None

9” and 12” floor tile and mastic under carpet Basement, 1st, and 2nd floors None

Building 20 – Auto cleaning shop (Old Boiler House)

Condition

Water tank insulation and debris on floor 3rd floor N.W. loft None

Steam pipe insulation

1st floor S.W. garage, 1st floor old boiler room at ceiling at N. end, 2nd floor N.W. mechanical room, and 3rd floor N.W. loft

None

Exterior window frame caulking 1st, 2nd, and 3rd floor metal windows None

White sink undercoating 2nd floor room 202 None

Building 22 - Locksmith Building

Condition

Steam pipe insulation Floor trenches under wood cover

Removed per report provided by VA 12-22-22

Building 23 - Acquisition, Material Management

Condition

Steam pipe insulation

Basement (N. and S. sides)

Removed 12 lf of insulation on N. side of

Basement; No change 6/14/23

Building 24 - Geriatrics, Shared Medical Appointments

Condition

12” floor tile and mastic (most located under carpeting)

Basement GC109B, GB116, GB120, GB113, GBS1, and GA51

Black residual mastic under carpet Basement GB113 None

Building 25 - Laundry Building

Condition

Asbestos contaminated soils under concrete cap Crawl spaces under building

Crawlspace abated per VA Report info 12-22-22 No change 6/14/23

Mud fittings on fiberglass insulated pipes Basement mechanical room 1 and Room 105 on 1st floor

75’ removed from Mech Room in basement per VA report of 12-22-22 approximately 50’ remains in area, No change 6/14/23

12” floor tile and mastic 1st Floor Rooms 107, 108, and 108 None

Interior window glazing on metal windows All 1st floor windows None

Building 26 - Kinesiotherapy, Mental Health

Condition

Asbestos contaminated soils under concrete cap

Crawl spaces under building None

Building 27 - GI, Diabetic, OT Clinics, Medical Records, Special

Condition

9” green floor tile and mastic 1st and 2nd floor stairwells None

Residual mastic located under carpeting and vinyl plank flooring Basement, 1st, and 2nd floors None

Building 28 - Veteran's Canteen Service

Condition

Steam pipe insulation Basement Room 3, 1st floor hallway and Room 8, men’s restroom removed

Men’s restroom TSI has been removed, No change 6/14/23

9” and 12” vinyl floor tile and mastic 2nd floor (all under carpet except stairwell)

Building 29 – Hoptel (vacant)

• All known asbestos materials were removed from this building.

Building 30 - Medical Intensive Care Unit

Condition

Asbestos contaminated soils under concrete cap

Crawl spaces under building (N. and S.)

Removed per report 12- 22-22, No change 6/14/23

Steam and domestic water pipe insulation Ground floor room 6 and 1st floor room

121. Also assumed to be in pipe chases

Material removed from Mech Room., No change 6/14/23

9” and 12” floor tile and mastic Ground floor, 1st, and 2nd floors Removed from 4a to 4H and Hall, No change

Building 31 - Mental Health Offices, Domiciliary

Condition

Black mastic under 12” vinyl floor tile, carpeting, and vinyl plank flooring

Basement, 1st, and 2nd floors None

Building 35 - Voluntary Services

Condition

Asbestos contaminated soils under concrete cap

Crawl spaces under building (N. and S.)

None

Residual black mastic under 12” vinyl floor tile, 18” floor tile, carpeting, and vinyl plank flooring

Basement, 1st, and 2nd floors

Building 36 - Tool Room Building

Condition

Steam pipe insulation Basement perimeter pipe runs None

Exterior window frame caulking 1st floor windows None

Building 179 - Storage Building

Condition

Transite cement siding Exterior

Damage to Transite siding on ground with debris – still damaged

Building 210 - Extended Care Unit

Building 211 - Echo, EEG, EKG/Holter, KT

Building 212 - Administration Offices/Storage

Condition

9” and 12” floor tile and mastic (including under carpeting) Basement, 1st, and 2nd floors None

Undercoating on metal sinks Rooms 221 and 222 None

Exterior window caulking Windows on basement, 1st, and 2nd None

Building 228 – Shops (Pest Control, Paint, and Electrical)

Condition

12” tan floor tile (negative mastic) Break area None

Transite wall panels Room 102 None

Steam pipe insulation Rooms 101, 102, 102A and 103A None

Building 247 - Gymnasium, Pool

Condition

Asbestos contaminated soils under concrete cap

Crawl space None

Building 252 – Chapel

Condition

Interior window caulking Interior windows None

Interior caulking on windows and brick seams Exterior windows and brick seams None 9” vinyl floor tile and black mastic under carpeting

Rooms 104, 111 and hallway None

12” vinyl floor tile under carpet Sanctuary room 101 None

Building T38-40 - Engineering 5 - Storage and Shops

• There are no asbestos materials identified in this building.

Building T-41 - Engineering 2 Storage Building

Condition

Asbestos cement siding Exterior siding of building + debris on ground

Wall falling in on building, significant damage observed

Asbestos cement roof shingles Roofing Damaged

9” and 12” vinyl floor tile and mastic 101, 102, and 102A None

Building T-52 – Greenhouse

Building T-233 Engineering/Storage

3.0 CONCLUSION/RECOMMENDATIONS

An operations and maintenance (O&M) program has been developed by the VAMC specifically for the positively identified ACBM in the facilities. Any renovation/demolition work which may impact these positive materials should be conducted in accordance with the O&M program and all applicable Federal, state, and local regulations by appropriately trained and VA-approved personnel and contractors. Since demolition was not performed as part of the inspection work at the facilities, certain areas such as pipe chases and areas above fixed permanent ceilings, fire-door interiors, and vault/safe wall and door linings were not inspected or tested. Prior to renovation and alteration work which could impact these areas, Castle Hill recommends that exploratory demolition be performed and a qualified inspector be utilized to examine the areas and collect samples as needed. Castle Hill recommends sampling of roofing materials and electrical components (not specifically examined as part of this survey) if renovation activities are planned which may disturb these materials.

Inspector Signature:

Priscilla Bersee Asbestos Hazard Evaluation Specialist Ohio EPA License #ES36153

Project Manager, Brett L. Brumbaugh, REPA, CESCO

Asbestos Hazard Evaluation Specialist Ohio EPA License #ES3488

TABLE 1

LIST OF ACRONYMS

ACBM Asbestos Containing Building Material ACM Asbestos Containing Material AHERA Asbestos Hazard Emergency Response Act AIHA American Industrial Hygiene Association CAA Clean Air Act CFR Code of Federal Regulations EPA United States Environmental Protection Agency HazCom Hazard Communication HEPA High Efficiency Particulate Air Filter HVAC Heating, Ventilation, and Air Conditioning MISC Miscellaneous Asbestos Containing Material NESHAP National Emission Standards for Hazardous Air Pollutants NIOSH National Institute for Occupational Safety and Health NIST National Institute of Standards and Technology NOB Non-friable Organically Bound NVLAP National Voluntary Laboratory Accreditation Program OEPA Ohio EPA OSHA Occupational Safety and Health Administration PAT AIHA Proficiency Analytical Testing Program PCM Phase Contrast Microscopy PEL Permissible Exposure Limit PLM Polarized Light Microscopy TEM Transmission Electron Microscopy TSCA Toxic Substances Control Act TSI Thermal Systems Insulation Castle Hill Castle Hill Associates, LLC VA United States Department of Veterans Affairs VAMC VA Medical Center XRD X-Ray Diffraction

APPENDIX A

Asbestos Quantities and Assessments

Monday, June 26, 2023 Page 1 of 77 ACM Materials Project No. 5887.01

Building Number 1

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 06 Floor Tile and associated

Mastic underneath Carpet 135 s.f. Second Floor Positive204NF-I

06 Mastic underneath Carpet 230 s.f. Basement PositiveBA118NF-I

06 Mastic underneath Carpet 100 s.f. Basement PositiveBA116NF-I

06 Floor Tile and associated Mastic underneath Carpet

195 s.f. First Floor Positive138NF-I

06 Floor Tile and associated Mastic underneath Carpet

50 s.f. First Floor Positive139NF-I

06 Floor Tile and associated mastic underneath carpet

600 s.f. Second Floor Positive264NF-I

06 Floor Tile and associated Mastic underneath Carpet

85 s.f. Second Floor Positive217NF-I

06 Floor Tile and associated Mastic underneath Carpet

170 s.f. Second Floor Positive281NF-I

06 Floor Tile and associated Mastic underneath Carpet

120 s.f. Second Floor Positive280NF-I

06 Floor Tile and associated Mastic underneath Carpet

75 s.f. First Floor Positive147NF-I

06 Floor Tile and associated Mastic underneath Carpet

640 s.f. First Floor Positive163NF-I

06 Floor Tile and associated Mastic underneath Carpet

120 s.f. Basement PositiveBB105NF-I

06 Floor Tile and associated Mastic underneath Carpet

100 s.f. First Floor Positive172NF-I

06 Floor Tile and associated Mastic underneath Carpet

135 s.f. Second Floor Positive243NF-I

06 Floor Tile and associated Mastic underneath Carpet

85 s.f. Second Floor Positive244NF-I

06 Floor Tile and associated Mastic underneath Carpet

135 s.f. First Floor Positive154NF-I

06 Floor Tile and associated Mastic underneath Carpet

135 s.f. First Floor Positive155NF-I

06 Floor Tile and associated Mastic underneath Carpet

135 s.f. First Floor Positive157NF-I

06 Floor Tile and associated Mastic underneath Carpet

150 s.f. Second Floor Positive202NF-I

Building Number 1

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 06 Floor Tile and associated

Mastic underneath Carpet 150 s.f. First Floor Positive131NF-I

06 Floor Tile and associated Mastic underneath Carpet

205 s.f. Second Floor Positive209NF-I

06 Floor Tile and associated Mastic underneath Carpet

120 s.f. First Floor Positive162NF-I

06 Floor Tile and associated Mastic underneath Carpet

135 s.f. First Floor Positive132NF-I

06 Floor Tile and associated Mastic underneath Carpet

160 s.f. Second Floor Positive230NF-I

06 Floor Tile and associated Mastic underneath Carpet

120 s.f. Second Floor Positive259NF-I

06 Floor Tile and associated Mastic underneath Carpet

315 s.f. First Floor Positive119NF-I

06 Floor Tile and associated Mastic underneath Carpet

135 s.f. First Floor Positive133NF-I

06 Floor Tile and associated Mastic underneath Carpet

145 s.f. First Floor Positive118NF-I

06 Floor Tile and associated Mastic underneath Carpet

135 s.f. Second Floor Positive247NF-I

06 Floor Tile and associated Mastic underneath Carpet

360 s.f. Second Floor Positive246NF-I

06 Floor Tile and associated Mastic underneath Carpet

180 s.f. Second Floor Positive216NF-I

06 Floor Tile and associated Mastic underneath Carpet

145 s.f. Second Floor Positive263NF-I

06 Floor Tile and associated Mastic underneath Carpet

120 s.f. Second Floor Positive262NF-I

06 Floor Tile and associated Mastic underneath Carpet

170 s.f. First Floor Positive112NF-I

06 Floor Tile and associated Mastic underneath Carpet

145 s.f. Second Floor Positive205NF-I

06 Floor Tile and associated Mastic underneath Carpet

300 s.f. First Floor Positive170NF-I

06 Floor Tile and associated Mastic underneath Carpet

110 s.f. First Floor Positive141NF-I

06 Floor Tile and associated Mastic underneath Carpet

170 s.f. First Floor Positive171NF-I

Monday, June 26, 2023

Building Number 1

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 06 Floor Tile and associated

Mastic underneath Carpet 110 s.f. First Floor Positive140NF-I

06 Floor Tile and associated Mastic underneath Carpet

180 s.f. First Floor Positive181NF-I

06 Floor Tile and associated Mastic underneath Carpet

100 s.f. First Floor Positive180NF-I

06 Floor Tile and associated Mastic underneath Carpet

120 s.f. First Floor Positive179NF-I

06 Floor Tile and associated Mastic underneath Carpet

170 s.f. First Floor Positive178NF-I

06 Floor Tile and associated Mastic underneath Carpet

50 s.f. First Floor Positive177NF-I

06 Floor Tile and associated Mastic underneath Carpet

180 s.f. First Floor Positive176NF-I

06 Floor Tile and associated Mastic underneath Carpet

120 s.f. First Floor Positive175NF-I

06 Floor Tile and associated Mastic underneath Carpet

195 s.f. First Floor Positive174NF-I

06 Mastic underneath Carpet 100 s.f. Basement PositiveBA101BNF-I

06 Floor Tile and associated Mastic underneath Carpet

150 s.f. First Floor Positive114NF-I

06 Floor Tile and associated Mastic underneath Carpet

220 s.f. Second Floor Positive238NF-I

06 Floor Tile and associated Mastic underneath Carpet

100 s.f. First Floor Positive123NF-I

06 Floor Tile and associated Mastic underneath Carpet

85 s.f. Second Floor Positive210NF-I

06 Floor Tile and associated Mastic underneath Carpet

100 s.f. First Floor Positive124NF-I

06 Floor Tile and associated Mastic underneath Carpet

135 s.f. First Floor Positive158NF-I

06 Floor Tile and associated Mastic underneath Carpet

170 s.f. First Floor Positive115NF-I

06 Floor Tile and associated Mastic underneath Carpet

150 s.f. First Floor Positive113NF-I

06 Floor Tile and associated Mastic underneath Carpet

160 s.f. Second Floor Positive227NF-I

Building Number 1

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 06 Floor Tile and associated

Mastic underneath Carpet 150 s.f. Second Floor Positive201NF-I

06 Floor Tile and associated Mastic underneath Carpet

120 s.f. Second Floor Positive234NF-I

06 Floor Tile and associated Mastic underneath Carpet

265 s.f. First Floor Positive116NF-I

06 Floor Tile and associated Mastic underneath Carpet

85 s.f. Second Floor Positive237NF-I

06 Floor Tile and associated Mastic underneath Carpet

100 s.f. First Floor Positive122NF-I

06 Floor Tile and associated Mastic underneath Carpet

135 s.f. First Floor Positive129NF-I

06 Floor Tile and associated Mastic underneath Carpet

165 s.f. First Floor Positive143NF-I

06 Floor Tile and associated Mastic underneath Carpet

290 s.f. Second Floor Positive254NF-I

06 Floor Tile and associated Mastic underneath Carpet

135 s.f. First Floor Positive128NF-I

06 Floor Tile and associated Mastic underneath Carpet

195 s.f. Second Floor Positive255NF-I

06 Floor Tile and associated Mastic underneath Carpet

170 s.f. First Floor Positive127NF-I

06 Floor Tile and associated Mastic underneath Carpet

120 s.f. Second Floor Positive256NF-I

06 Floor Tile and associated Mastic underneath Carpet

120 s.f. First Floor Positive126NF-I

06 Floor Tile and associated Mastic underneath Carpet

150 s.f. Second Floor Positive257NF-I

06 Floor Tile and associated Mastic underneath Carpet

150 s.f. Second Floor Positive258NF-I

06 Floor Tile and associated Mastic underneath Carpet

160 s.f. Second Floor Positive235NF-I

06 Floor Tile and associated Mastic underneath Carpet

120 s.f. Second Floor Positive224ANF-I

06 Mastic underneath Carpet 100 s.f. Basement PositiveBA101NF-I

06 Floor Tile and associated Mastic underneath Carpet

220 s.f. First Floor Positive164NF-I

Building Number 1

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 06 Floor Tile and associated

Mastic underneath Carpet 150 s.f. Second Floor Positive203NF-I

06 Floor Tile and associated Mastic underneath Carpet

145 s.f. First Floor Positive165NF-I

06 Floor Tile and associated Mastic underneath Carpet

135 s.f. First Floor Positive166NF-I

06 Floor Tile and associated Mastic underneath Carpet

170 s.f. First Floor Positive167NF-I

06 Floor Tile and associated Mastic underneath Carpet

160 s.f. Second Floor Positive233NF-I

06 Floor Tile and associated Mastic underneath Carpet

240 s.f. First Floor Positive168NF-I

06 Floor Tile and associated Mastic underneath Carpet

385 s.f. First Floor Positive110NF-I

06 Floor Tile Under 12"X12" Blue Green Floor Tile with White Smudges and associated Mastic

250 s.f. Basement PositiveBA102NF-I

06 Floor Tile and associated Mastic underneath Carpet

580 s.f. Second Floor Positive231NF-I

06 Floor Tile and associated Mastic underneath Carpet

420 s.f. Second Floor Positive224NF-I

06 Floor Tile and associated Mastic underneath Carpet

440 s.f. First Floor Positive121NF-I

06 Floor Tile and associated Mastic underneath Carpet

120 s.f. Second Floor Positive260NF-I

06 Floor Tile and associated Mastic underneath Carpet

120 s.f. Second Floor Positive224BNF-I

06 Floor Tile and associated Mastic underneath Carpet

220 s.f. Second Floor Positive220NF-I

06 Floor Tile and associated Mastic underneath Carpet

160 s.f. Second Floor Positive225NF-I

06 Mastic underneath Carpet 135 s.f. Basement PositiveBA114NF-I

06 Floor Tile and associated Mastic underneath Carpet

145 s.f. Second Floor Positive261NF-I

06 Floor Tile and associated Mastic underneath Carpet

145 s.f. Second Floor Positive219NF-I

Building Number 1

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 06 Floor Tile and associated

Mastic underneath Carpet 145 s.f. Second Floor Positive226NF-I

06 Floor Tile and associated Mastic underneath Carpet

160 s.f. Second Floor Positive232NF-I

06 Floor Tile and associated Mastic underneath Carpet

50 s.f. First Floor Positive149NF-I

06 Floor Tile and associated Mastic underneath Carpet

100 s.f. First Floor Positive136NF-I

06 Floor Tile and associated Mastic underneath Carpet

205 s.f. Second Floor Positive223NF-I

06 Mastic underneath Carpet 100 s.f. Basement PositiveBA105NF-I

06 Floor Tile and associated Mastic underneath Carpet

135 s.f. Second Floor Positive269NF-I

06 Floor Tile and associated Mastic underneath Carpet

160 s.f. Second Floor Positive214NF-I

06 Floor Tile and associated Mastic underneath Carpet

170 s.f. First Floor Positive134NF-I

06 Floor Tile and associated Mastic underneath Carpet

145 s.f. Second Floor Positive270NF-I

06 Floor Tile and associated Mastic underneath Carpet

135 s.f. Second Floor Positive271NF-I

06 Floor Tile and associated Mastic underneath Carpet

120 s.f. Second Floor Positive272NF-I

06 Mastic underneath Carpet 110 s.f. Basement PositiveBA111NF-I

06 Floor Tile and associated Mastic underneath Carpet

150 s.f. Second Floor Positive274NF-I

06 Mastic underneath Carpet 110 s.f. Basement PositiveBA110NF-I

06 Floor Tile and associated Mastic underneath Carpet

135 s.f. First Floor Positive144NF-I

06 Mastic underneath Carpet 160 s.f. Basement PositiveBA112NF-I

06 Floor Tile and associated Mastic underneath Carpet

120 s.f. Second Floor Positive275NF-I

06 Floor Tile and associated Mastic underneath Carpet

135 s.f. Second Floor Positive276NF-I

06 Floor Tile and associated Mastic underneath Carpet

170 s.f. Second Floor Positive277NF-I

Building Number 1

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 06 Floor Tile and associated

Mastic underneath Carpet 170 s.f. Second Floor Positive279NF-I

06 Floor Tile and associated Mastic underneath Carpet

135 s.f. First Floor Positive102NF-I

06 Floor Tile and associated Mastic underneath Carpet

150 s.f. First Floor Positive103NF-I

06 Floor Tile and associated Mastic underneath Carpet

150 s.f. Second Floor Positive273NF-I

06 Floor Tile and associated Mastic underneath Carpet

150 s.f. First Floor Positive130NF-I

06 Floor Tile and associated Mastic underneath Carpet

160 s.f. Second Floor Positive218NF-I

06 Floor Tile and associated Mastic underneath Carpet

135 s.f. First Floor Positive145NF-I

06 Floor Tile and associated Mastic underneath Carpet

36 s.f. First Floor Positive169ANF-I

06 Floor Tile and associated Mastic underneath Carpet

160 s.f. Second Floor Positive211NF-I

06 Floor Tile and associated Mastic underneath Carpet

160 s.f. First Floor Positive161NF-I

06 Floor Tile and associated Mastic underneath Carpet

120 s.f. Second Floor Positive228NF-I

06 Floor Tile and associated Mastic underneath Carpet

120 s.f. First Floor Positive160NF-I

06 Floor Tile and associated Mastic underneath Carpet

145 s.f. Second Floor Positive268NF-I

06 Floor Tile and associated Mastic underneath Carpet

240 s.f. Second Floor Positive245ANF-I

06 Mastic underneath Carpet 160 s.f. Basement PositiveBA107NF-I

06 Floor Tile and associated Mastic underneath Carpet

150 s.f. Second Floor Positive245NF-I

06 Floor Tile and associated Mastic underneath Carpet

940 s.f. Second Floor Positive265NF-I

06 Floor Tile and associated Mastic underneath Carpet

195 s.f. Second Floor Positive266NF-I

06 Floor Tile and Associated Mastic Under Carpet

4299 s.f. Second Floor PositiveHallwayNF-I

Building Number 1

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 06 Floor Tile and associated

Mastic underneath Carpet 100 s.f. Second Floor Positive267NF-I

06 Floor Tile and associated Mastic underneath Carpet

270 s.f. Second Floor Positive215NF-I

06 Floor Tile and associated Mastic underneath Carpet

160 s.f. Second Floor Positive229NF-I

06 Floor Tile and associated Mastic underneath Carpet

120 s.f. First Floor Positive105NF-I

06 Floor Tile and associated Mastic underneath Carpet

170 s.f. First Floor Positive153NF-I

06 Floor Tile and associated Mastic underneath Carpet

3950 s.f. First Floor PositiveHallwayNF-I

06 Floor Tile and associated Mastic underneath Carpet

135 s.f. Second Floor Positive212NF-I

06 Floor Tile and associated Mastic underneath Carpet

145 s.f. Second Floor Positive213NF-I

06 Floor Tile and associated Mastic underneath Carpet

240 s.f. First Floor Positive120NF-I

06 Floor Tile and associated Mastic underneath Carpet

170 s.f. First Floor Positive159NF-I

06 Floor Tile and associated Mastic underneath Carpet

800 s.f. Basement PositiveHallway

CB2-CB3

NF-I

06 Floor Tile and associated Mastic underneath Carpet

135 s.f. First Floor Positive101NF-I

06 Mastic underneath Carpet 120 s.f. Basement PositiveBA113NF-I

06 Mastic underneath Carpet 120 s.f. Basement PositiveBA108NF-I

06 Mastic underneath Carpet 100 s.f. Basement PositiveBA101CNF-I

06 Mastic underneath Carpet 100 s.f. Basement PositiveBA103NF-I

06 Floor Tile and associated Mastic underneath Carpet

145 s.f. First Floor Positive125NF-I

06 Mastic underneath Carpet 135 s.f. Basement PositiveBA109NF-I

06 Floor Tile and associated Mastic underneath Carpet

120 s.f. First Floor Positive104NF-I

06 Mastic underneath Carpet 100 s.f. Basement PositiveBA101DNF-I

Building Number 1

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 06 Floor Tile and associated

Mastic underneath Carpet 145 s.f. First Floor Positive111NF-I

06 Floor Tile and associated Mastic underneath Carpet

340 s.f. First Floor Positive169NF-I

06 Floor Tile and associated Mastic underneath Carpet

170 s.f. Second Floor Positive221NF-I

06 Floor Tile and associated Mastic underneath Carpet

315 s.f. First Floor Positive109NF-I

06 Floor Tile and associated Mastic underneath Carpet

170 s.f. First Floor Positive135NF-I

12 12" x 12" Beige Floor Tile with Multi-Colored Smudges and associated Mastic

225 s.f. Basement PositiveHallway

CB-1

NF-I

12 12" x 12" Beige Floor Tile with Multi-Colored Smudges and associated Mastic

200 s.f. Basement PositiveEast Stairwell

NF-I

12 12" x 12" Beige Floor Tile with Multi-Colored Smudges and associated Mastic

175 s.f. Basement PositiveHallway

CB-4

NF-I

12 12" x 12" Beige Floor Tile with Multi-Colored Smudges and associated Mastic

200 s.f. Basement PositiveWest Stairwell

NF-I

13 12" x 12" Light Brown Floor Tile with Red and White Smudges and associated Mastic

555 s.f. Basement PositiveHallway

CB-5

NF-I

13 12" x 12" Light Brown Floor Tile with Red and White Smudges and associated Mastic

375 s.f. Basement PositiveBB102NF-I

13 12" x 12" Light Brown Floor Tile with Red and White Smudges and associated Mastic

825 s.f. Basement PositiveBB103NF-I

13 12" x 12" Light Brown Floor Tile with Red and White Smudges and associated Mastic

90 s.f. Basement PositiveBC100DNF-I

Building Number 1

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 13 Black Residual Mastic associated with removed 12" x 12" Light Brown Floor Tile with Red and White Smudges

90 s.f. Basement PositiveBC100ENF-I

13 12" x 12" Light Brown Floor Tile with Red and White Smudges and associated Mastic

180 s.f. Basement PositiveBC100GNF-I

13 12" x 12" Light Brown Floor Tile with Red and White Smudges and associated Mastic

500 s.f. Basement PositiveBC100BNF-I

13 12" x 12" Light Brown Floor Tile with Red and White Smudges and associated Mastic

300 s.f. Basement PositiveBC100ANF-I

13 12" x 12" Light Brown Floor Tile with Red and White Smudges and associated Mastic

610 s.f. Basement PositiveBC100NF-I

13 12" x 12" Light Brown Floor Tile with Red and White Smudges and associated Mastic

160 s.f. Basement PositiveBB108NF-I

19 Grey Cement Wall Panel 35 s.f. Basement PositiveBetween Rooms

BB104

And

BB106

NF-II

6 Floor Tile and associated Mastic underneath Carpet

135 s.f. First Floor Positive182NF-I

Building Number 10

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 05 12" x 12" Off-White Floor Tile with Brown Streaks and associated Mastic

50 s.f. First Floor PositiveCenter Stairwell

NF-I

11 9" x 9" Floor Tile and associated Mastic underneath Carpet

280 s.f. First Floor Positive113NF-I

11 9" x 9" Floor Tile and associated Mastic underneath Carpet

170 s.f. First Floor Positive110NF-I

Building Number 10

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 11 9" x 9" Floor Tile and associated Mastic underneath Carpet

140 s.f. First Floor Positive111NF-I

11 9" x 9" Floor Tile and associated Mastic underneath Carpet

225 s.f. First Floor PositiveHallwayNF-I

11 9" x 9" Floor Tile and associated Mastic underneath Carpet

170 s.f. First Floor Positive105NF-I

11 9" x 9" Floor Tile and associated Mastic underneath Carpet

155 s.f. First Floor Positive112NF-I

11 9" x 9" Floor Tile and associated Mastic underneath Carpet

140 s.f. First Floor Positive104NF-I

11 9" x 9" Floor Tile and associated Mastic underneath Carpet

140 s.f. First Floor Positive109NF-I

11 9" x 9" Floor Tile and associated Mastic underneath Carpet

310 s.f. First Floor Positive102NF-I

11 9" x 9" Floor Tile and associated Mastic underneath Carpet

140 s.f. First Floor Positive103NF-I

13 Grey Thermal Pipe Insulation and Fittings with Cloth Wrap

35 l.f. First Floor Positive105F

13 Grey Thermal Pipe Insulation and Fittings with Cloth Wrap

75 l.f. Basement PositiveCrawl Space

F

13 Grey Thermal Pipe Insulation and Fittings with Cloth Wrap

30 l.f. Basement PositiveTank Room

F

13 Grey Thermal Pipe Insulation and Fittings with Cloth Wrap

11 each Basement PositiveTank Room

F

14 Yellow Mastic Under Ceramic Wall Tile

200 s.f. First Floor PositiveHallwayNF-I

Building Number 11

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 06 12" x 12" Off White Floor Tile with Brown Streaks and associated Mastic

20 s.f. Basement Positive3NF-I

Building Number 11

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 06 12" x 12" Off White Floor Tile with Brown Streaks and associated Mastic

210 s.f. Basement Positive1NF-I

06 12" x 12" Off White Floor Tile with Brown Streaks and associated Mastic

100 s.f. First Floor PositiveEntrywayNF-I

06 12" x 12" Off White Floor Tile with Brown Streaks and associated Mastic (under carpet)

250 s.f. Second Floor Positive205NF-I

06 12" x 12" Off White Floor Tile with Brown Streaks and associated Mastic

30 s.f. Basement Positive2ANF-I

06 12" x 12" Off White Floor Tile with Brown Streaks and associated Mastic (under carpet)

250 s.f. Second Floor Positive206NF-I

06 12" x 12" Off White Floor Tile with Brown Streaks and associated Mastic (under carpet)

50 s.f. Second Floor Positive208ANF-I

06 12" x 12" Off White Floor Tile with Brown Streaks and associated Mastic

250 s.f. First Floor Positive111NF-I

06 12" x 12" Off White Floor Tile with Brown Streaks and associated Mastic (under carpet)

300 s.f. Second Floor Positive212ANF-I

06 12" x 12" Off White Floor Tile with Brown Streaks and associated Mastic (2nd layer)

250 s.f. First Floor Positive107NF-I

06 12" x 12" Off White Floor Tile with Brown Streaks and associated Mastic (under carpet)

250 s.f. Second Floor Positive214NF-I

06 12" x 12" Off White Floor Tile with Brown Streaks and associated Mastic (under carpet)

250 s.f. Second Floor Positive202NF-I

06 12" x 12" Off White Floor Tile with Brown Streaks and associated Mastic

245 s.f. Basement Positive2NF-I

Building Number 11

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 06 12" x 12" Off White Floor Tile with Brown Streaks and associated Mastic

300 s.f. First Floor PositiveHallwayNF-I

06 12" x 12" Off White Floor Tile with Brown Streaks and associated Mastic

250 s.f. First Floor Positive110ANF-I

06 12" x 12" Off White Floor Tile with Brown Streaks and associated Mastic (under carpet)

300 s.f. Second Floor Positive212NF-I

06 12" x 12" Off White Floor Tile with Brown Streaks and associated Mastic (under carpet)

250 s.f. Second Floor Positive208NF-I

06 12" x 12" Off White Floor Tile with Brown Streaks and associated Mastic (under carpet)

250 s.f. Second Floor Positive207NF-I

06 12" x 12" Off White Floor Tile with Brown Streaks and associated Mastic (under carpet)

250 s.f. Second Floor Positive201NF-I

06 12" x 12" Off-White Floor Tile with Brown Streaks and associated Mastic

450 s.f. PositiveStairwellsNF-I

06 12" x 12" Off White Floor Tile with Brown Streaks and associated Mastic (under carpet)

250 s.f. Second Floor Positive213NF-I

09 Yellow and Black Carpet Mastic

375 s.f. Second Floor PositiveHallwayNF-I

09 Yellow and Black Carpet Mastic

195 s.f. First Floor Positive106NF-I

09 Yellow and Black Carpet Mastic

80 s.f. First Floor Positive105NF-I

09 Yellow and Black Carpet Mastic

145 s.f. First Floor Positive104NF-I

09 Yellow and Black Carpet Mastic

195 s.f. First Floor Positive103NF-I

09 Yellow and Black Carpet Mastic

140 s.f. Second Floor Positive204NF-I

Building Number 11

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 09 Yellow and Black Carpet

Mastic 500 s.f. First Floor Positive102NF-I

09 Yellow and Black Carpet Mastic

160 s.f. First Floor Positive105ANF-I

09 Yellow and Black Carpet Mastic

714 s.f. PositiveRoom 12NF-II

09 Yellow and Black Carpet Mastic

155 s.f. Second Floor Positive203NF-I

14 Grey Thermal Pipe Insulation and Fittings with Cloth Wrap

35 l.f. First Floor Positive106F

14 Grey Thermal Pipe Insulation and Fittings with Cloth Wrap

255 l.f. Crawlspace and Tank Room

PositiveThroughou t

F

14 Grey Thermal Pipe Insulation and Fittings with Cloth Wrap

26 l.f. Basement PositiveThroughou t

F

15 Exterior Window/Door Caulk 1150 l.f. Exterior Window/Door PositiveNF-II

Building Number 17

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 03 12" x 12" Grey Floor Tile with

Maroon and Green Smudges and associated Mastic

55 s.f. Second Floor PositiveBathroomNF-I

04 12" x 12" Beige Floor Tile with Brown Streaks and associated Mastic

585 s.f. Basement PositiveNF-I

04 12" x 12" Beige Floor Tile with Brown Streaks and associated Mastic

160 s.f. Basement PositiveServing Kitchen

NF-I

04 12" x 12" Beige Floor Tile with Brown Streaks and associated Mastic

145 s.f. Basement PositiveBedroomNF-I

05 12" x 12" White Floor Tile with Black Streaks and associated Mastic

150 s.f. Basement PositiveUtility Room

NF-I

07 6" Black Cove Base and associated Black Mastic

50 l.f. Basement PositiveServing Kitchen

NF-I

18 9" x 9" Green and Black Floor Tile (checkered pattern) and Associated Mastic

70 s.f. Basement PositiveStorageNF-I

Building Number 179

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 1 Transite exterior siding 320 s.f. Exterior siding PositiveExteriorNF-I

Building Number 18

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 05 Residual Black Mastic associated with Removed 9" x 9" Floor Tile underneath Carpet

975 s.f. Second Floor Positive215NF-I

05 9" x 9" Floor Tile and associated Mastic underneath Floor Tile

135 s.f. Basement Positive5BNF-I

05 9" x 9" Floor Tile and associated Mastic underneath Carpet

180 s.f. Basement Positive5ANF-I

05 9" x 9" Floor Tile and associated Mastic underneath Carpet

625 s.f. Basement Positive5NF-I

05 9" x 9" Floor Tile and associated Mastic underneath Carpet

115 s.f. Basement Positive4NF-I

18 Grey Thermal Pipe Insulation and Fittings with Cloth Wrap

390 l.f. Basement PositiveThroughou t

F

18 Grey Thermal Pipe Insulation and Fittings with Cloth Wrap

6 l.f. Basement PositiveCenter Stairwell

F

18 Grey Thermal Pipe Insulation and Fittings with Cloth Wrap

40 l.f. Basement Positive8F

18 Grey Thermal Pipe Insulation and Fittings with Cloth Wrap

5 l.f. Basement Positive12F

Building Number 2

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 06 12" x 12" Off-White Floor Tile with Dark Streaks and associated Mastic

80 s.f. Second Floor Positive206NF-I

06 12" x 12" Off-White Floor Tile with Dark Streaks and associated Mastic

55 s.f. Second Floor Positive207ANF-I

06 12" x 12" Off-White Floor Tile with Dark Streaks and associated Mastic

500 s.f. First Floor PositiveSouth Hallway

NF-I

Building Number 2

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 06 12" x 12" Off-White Floor Tile with Dark Streaks and associated Mastic

480 s.f. Second Floor Positive207NF-I

06 12" x 12" Off-White Floor Tile with Dark Streaks and associated Mastic

30 s.f. First Floor Positive109ANF-I

06 12" x 12" Off-White Floor Tile with Dark Streaks and associated Mastic

240 s.f. First Floor Positive109NF-I

06 12" x 12" Off-White Floor Tile with Dark Streaks and associated Mastic

120 s.f. First Floor Positive102NF-I

06 12" x 12" Off-White Floor Tile with Dark Streaks and associated Mastic

120 s.f. First Floor Positive103NF-I

06 12" x 12" Off-White Floor Tile with Dark Streaks and associated Mastic

80 s.f. Second Floor Positive218NF-I

06 12" x 12" Off-White Floor Tile with Dark Streaks and associated Mastic

140 s.f. First Floor Positive104BNF-I

06 12" x 12" Off-White Floor Tile with Dark Streaks and associated Mastic

108 s.f. First Floor Positive121NF-I

06 12" x 12" Off-White Floor Tile with Dark Streaks and associated Mastic

120 s.f. First Floor Positive104CNF-I

06 12" x 12" Off-White Floor Tile with Dark Streaks and associated Mastic

1105 s.f. First Floor Positive108NF-I

06 12" x 12" Off-White Floor Tile with Dark Streaks and associated Mastic

450 s.f. First Floor PositiveStairwellsNF-I

06 12" x 12" Off-White Floor Tile with Dark Streaks and associated Mastic

140 s.f. First Floor Positive104ANF-I

06 12" x 12" Off-White Floor Tile with Dark Streaks and associated Mastic

155 s.f. First Floor Positive113NF-I

Building Number 2

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 06 12" x 12" Off-White Floor Tile with Dark Streaks and associated Mastic

65 s.f. First Floor Positive102NF-I

06 12" x 12" Off-White Floor Tile with Dark Streaks and associated Mastic

505 s.f. First Floor Positive106NF-I

10 Grey Thermal Pipe Wrap Insulation and Fittings with Cloth Wrap Debris

16 l.f. First Floor Positive113F

10 Grey Thermal Pipe Insulation and Fittings with Cloth Wrap

2 l.f. First Floor Positive105 Pipe chase

F

10 Grey Thermal Pipe Insulation and Fittings with Cloth Wrap

765 l.f. Pipe Basement PositiveCrawlspac e

F

10 Grey Thermal Pipe Wrap Insulation and Fittings with Cloth Wrap Debris

5400 s.f. Crawl Space PositiveF

10 Grey Thermal Pipe Insulation and Fittings with Cloth Wrap

24 l.f. First Floor Positive109F

10 Grey Thermal Pipe Insulation and Fittings with Cloth Wrap

1380 l.f. Pipe Basement PositiveTank Room

F

10 Grey Thermal Pipe Insulation and Fittings with Cloth Wrap

12 l.f. First Floor Positive103 Pipe chase

F

10 Grey Thermal Pipe Insulation and Fittings with Cloth Wrap Fittings

30 each Tank Room PositiveF

10 Grey Thermal Pipe Insulation and Fittings with Cloth Wrap

31 l.f. First Floor Positive111/112F

11 Hot Water Tank Insulation 125 s.f. Basement PositiveTank Room

F

12 12" x 12" Cream with Olive Streaks Floor Tile and Black Mastic

100 s.f. First Floor Positive118NF-II

13 12" x 12" Olive Floor Tile and Black Mastic

100 s.f. First Floor Positive118NF-I

14 Tar Roofing (Silver/Black) Flat Roofs on Two Back Porches

1144 s.f. Roof PositiveBack Porches

NF-I

Building Number 20

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom

Building Number 20

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 07 White Sink Undercoating 1 sink Second Floor Positive202NF-II

27 Debris on Floor 150 s.f. Third Floor PositiveF

31 Grey Exterior Window Caulk 425 l.f. Exterior Windows PositiveNF-II

32 Hot water tank insulation 330 s.f. Third Floor PositiveLoftF

33 Steam pipe insulation 425 l.f. First, Second, and Third Floors

PositiveGarage, boiler room, mechanica l room, and loft

F

Building Number 21

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 09 Floor Tile and associated

Mastic under Tan and Wood Pattern Brown Sheet Flooring

290 s.f. First Floor Positive28NF-I

09 Floor Tile and associated Mastic under Tan and Wood Pattern Brown Sheet Flooring

270 s.f. First Floor Positive30NF-I

14 Grey Thermal Pipe Insulation and Fittings with Cloth Wrap

150 l.f. Positive28AF

15 Contaminated Soil 240 s.f. Pipe Basement PositiveCrawlspac e

F

Building Number 212

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 05 White Sink Undercoating 1 Second Floor Positive221NF-II

06 Black Sink Undercoating 1 Second Floor Positive222NF-II

09 Grey Exterior Window Caulk 2128 l.f. Second Floor PositiveExterior Windows

NF-II

09 Grey Exterior Window Caulk 1108 l.f. Basement PositiveExterior Windows

NF-II

09 Grey Exterior Window Caulk 2008 l.f. First Floor PositiveExterior Windows

NF-II

16 12" x 12" Off-White Floor Tile with Brown Streaks and associated Mastic

145 s.f. Basement Positive5NF-I

Building Number 212

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 16 12" x 12" Off-White Floor Tile with Brown Streaks and associated Mastic

170 s.f. Basement PositiveNorth Stairwell

NF-I

16 12" x 12" Off-White Floor Tile with Brown Streaks and associated Mastic

170 s.f. Basement PositiveSouth Stairwell

NF-I

16 12" x 12" Off-White Floor Tile with Brown Streaks and associated Mastic

25 s.f. Basement Positive18NF-I

16 12" x 12" Off-White Floor Tile with Brown Streaks and associated Mastic

2080 s.f. Basement Positive12NF-I

16 12" x 12" Off-White Floor Tile with Brown Streaks and associated Mastic Under Carpet

490 s.f. Basement Positive14NF-I

16 12" x 12" Off-White Floor Tile with Brown Streaks and associated Mastic

1660 s.f. Basement PositiveHallwayNF-I

17 12" x 12" White Floor Tile with Dark Streaks and associated Mastic

1215 s.f. Basement Positive11NF-I

19 9" x 9" Green and White (Checker Pattern) Floor Tile and associated Mastic

405 s.f. Second Floor Positive239NF-I

19 9" x 9" Green and White (Checker Pattern) Floor Tile and associated Mastic

550 s.f. Second Floor PositiveNortheast Hallway

NF-I

19 9" x 9" Green and White (Checker Pattern) Floor Tile and associated Mastic

100 s.f. Second Floor Positive221ANF-I

19 9" x 9" Green and White (Checker Pattern) Floor Tile and associated Mastic - Under Beige Floor Tile with Brown Smudges

315 s.f. First Floor Positive122NF-I

19 9" x 9" Green and White (Checker Pattern) Floor Tile and associated Mastic

235 s.f. Basement PositiveHallwayNF-I

19 9" x 9" Green and White (Checker Pattern) Floor Tile and associated Mastic

135 s.f. Second Floor Positive204NF-I

Building Number 212

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 19 9" x 9" Green and White

(Checker Pattern) Floor Tile and associated Mastic underneath Carpet

90 s.f. Second Floor Positive203NF-I

19 9" x 9" Green and White (Checker Pattern) Floor Tile and associated Mastic

450 s.f. Second Floor Positive205NF-I

19 9" x 9" Green and White (Checker Pattern) Floor Tile and associated Mastic

2000 s.f. Second Floor PositiveCenter Hallway

NF-I

19 9" x 9" Green and White (Checker Pattern) Floor Tile and associated Mastic

100 s.f. Second Floor Positive226NF-I

19 9" x 9" Green and White (Checker Pattern) Floor Tile and associated Mastic

160 s.f. First Floor Positive121NF-I

19 9" x 9" Green and White (Checker Pattern) Floor Tile and associated Mastic - Under Carpet

420 s.f. First Floor Positive106NF-I

21 9" x 9" White with Green Smudges Floor Tile and associated Mastic

220 s.f. Second Floor Positive236NF-I

21 9" x 9" White with Green Smudges Floor Tile and associated Mastic underneath Carpet

220 s.f. First Floor Positive110NF-I

21 9" x 9" White with Green Smudges Floor Tile and associated Mastic

220 s.f. Second Floor Positive238NF-I

21 9" x 9" White with Green Smudges Floor Tile and associated Mastic underneath Carpet

220 s.f. First Floor Positive108NF-I

21 9" x 9" White with Green Smudges Floor Tile and associated Mastic

245 s.f. Second Floor Positive213NF-I

21 9" x 9" White with Green Smudges Floor Tile and associated Mastic underneath Carpet

540 s.f. First Floor Positive109NF-I

Building Number 212

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 21 9" x 9" White with Green

Smudges Floor Tile and associated Mastic

190 s.f. Second Floor Positive217NF-I

21 9" x 9" White with Green Smudges Floor Tile and associated Mastic

510 s.f. Second Floor Positive237NF-I

21 9" x 9" White with Green Smudges Floor Tile and associated Mastic underneath Carpet

145 s.f. First Floor Positive111NF-I

21 9" x 9" White with Green Smudges Floor Tile and associated Mastic

510 s.f. Second Floor Positive207NF-I

21 9" x 9" White with Green Smudges Floor Tile and associated Mastic - Under 12"X12" Tan Speckled Floor Tile

85 s.f. First Floor Positive136NF-I

21 9" x 9" White with Green Smudges Floor Tile and associated Mastic - Under 14"X14" Granite Tile

365 s.f. First Floor Positive138NF-I

21 9" x 9" White with Green Smudges Floor Tile and associated Mastic

220 s.f. Second Floor Positive206NF-I

21 9" x 9" White with Green Smudges Floor Tile and associated Mastic underneath Carpet

365 s.f. First Floor Positive107NF-I

21 9" x 9" White with Green Smudges Floor Tile and associated Mastic - Under Carpet

300 s.f. First Floor PositiveNortheast Hallway

NF-I

21 9" x 9" White with Green Smudges Floor Tile and associated Mastic

135 s.f. Second Floor Positive235NF-I

21 9" x 9" White with Green Smudges Floor Tile and associated Mastic

135 s.f. Second Floor Positive209NF-I

21 9" x 9" White with Green Smudges Floor Tile and associated Mastic - Under Carpet

300 s.f. First Floor PositiveSoutheast Hallway

Building Number 212

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 21 9" x 9" White with Green

Smudges Floor Tile and associated Mastic

200 s.f. Second Floor PositiveNortheast Hallway

NF-I

21 9" x 9" White with Green Smudges Floor Tile and associated Mastic

300 s.f. Second Floor PositiveSoutheast Hallway

NF-I

21 9" x 9" White with Green Smudges Floor Tile and associated Mastic

200 s.f. First Floor PositiveSouthwest Hallway

NF-I

21 9" x 9" White with Green Smudges Floor Tile and associated Mastic

220 s.f. Second Floor Positive208NF-I

22 9" x 9" White with Brown Smudges Floor Tile and associated Mastic underneath Carpet

200 s.f. Second Floor Positive220NF-I

22 9" x 9" White with Brown Smudges Floor Tile and associated Mastic

245 s.f. Second Floor Positive231NF-I

22 9" x 9" White with Brown Smudges Floor Tile and associated Mastic

265 s.f. Second Floor Positive240NF-I

22 9" x 9" White with Brown Smudges Floor Tile and associated Mastic

240 s.f. Second Floor Positive224NF-I

22 9" x 9" White with Brown Smudges Floor Tile and associated Mastic

155 s.f. Second Floor Positive219NF-I

23 9" x 9" Green Floor Tile and associated Mastic underneath Carpet

265 s.f. First Floor Positive115NF-I

23 9" x 9" Green Floor Tile and associated Mastic

200 s.f. Second Floor PositiveNorthwest Hallway

NF-I

23 9" x 9" Green Floor Tile and associated Mastic

450 s.f. Second Floor Positive215NF-I

23 9" x 9" Green Floor Tile and associated Mastic underneath Carpet

265 s.f. First Floor Positive119NF-I

23 9" x 9" Green Floor Tile and associated Mastic underneath Carpet

220 s.f. First Floor Positive118NF-I

Building Number 212

HSA Number Material Description Friability Quantity Units Material Location Sample ResultRoom 23 9" x 9" Green Floor Tile and associated Mastic underneath Carpet

480 s.f. First Floor Positive117NF-I

23 9" x 9" Green Floor Tile and associated Mastic

450 s.f. Second Floor Positive229NF-I

23 9" x 9" Green Floor Tile and associated Mastic

265 s.f. Second Floor Positive216NF-I

23 9" x 9" Green Floor Tile and associated Mastic

220 s.f. Second Floor Positive214NF-I

23 9" x 9" Green Floor Tile and associated Mastic

220 s.f. Second Floor…