S06 - Amendment 0007 Att 11 - 14.077_031-EP100 - ELECTRICAL PLAN - GROUND FLOOR.pdf
PDF 1 MB Posted
- Attached to
- Y1DA--538-21-701 EHRM Infrastructure Upgrades Construction Chillicothe, OH (VA-23-00066755)
- Solicitation number
- 36C77623B0058
About this file
This document contains an electrical plan for infrastructure upgrades at the Chillicothe VA Medical Center in Chillicothe, Ohio. The plan provides details on new and updated electrical systems for the ground floor, including locations for new and existing panelboards, receptacles, lighting, switches, data systems, and HVAC equipment. Key areas that will receive electrical work include telecom closets, electrical rooms, and areas with new or replaced HVAC systems. System details include circuiting plans and notes for equipment such as disconnects, busbars, and power supplies.
The related federal contract opportunity is a solicitation for construction services for the EHRM Infrastructure Upgrades project at the Chillicothe VAMC. The solicitation number is 36C77623B0058 and was issued by the Department of Veterans Affairs Technology Acquisition Center in Austin, Texas. The opportunity identification in the Federal Business Opportunities database is VA-23-00066755. The solicitation is for upgrading and replacing infrastructure systems as detailed in the electrical plan and related construction documents.
View the file
Other files
Show 40 more
Latest 50 of 65 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
DN
UP
DN
UP
DN
DN
DN
DN
DN
UP
REF.
AP
AP
2D/1V 6D
AP
AP
AP
AP
AP
AP
M H
W
W
2D/1V
2D/1V
2D/1V
2D /1
V
2D/1V
6D
AP
2D/1V
AP
2D/1V
AP
2D/1V 2D/1V
2D/1V
2D/1V 2D/1V 2D/1V
2D/1V
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
AP
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
AP
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
AP
AP
2D/1V
2D/1V
AP
2D/1V
2D/1V 2D/1V
2D/1V
AP
AP
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D /1
V
2D/1V
AP
AP
2D/1V
2D/1V2D/1V
2D/1V2D/1VAP
AP
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
APAP 2D/1V
2D /1
V
AP
2D/1V
AP
2D/1V
1D
2D/1V 2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V 2D /1
V
2D/1V
AP
AP
2D/1V
2D/1V
2D/1V2D/1V
AP
AP
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V2D/1V
2D/1V
2D/1V
1V1V
2D/1V
2D /1
V
2D /1
V
1V 2D/1V 1V
2D/1V
2D/1V2D/1V
2D/1V
2D/1V 2D/1V
2D/1V2D/1V
2D/1V 2D/1V
AP
2D/1V
AP
2D/1V2D/1V 1V 1V
2D/1V
1V 1V
2D/1V
AP
AP
AP
AP
2D/1V2D/1V
1V 2D/1V
2D /1
V
2D/1V
AP
AP2D/1V
2D/1V
AP
2D/1V2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
AP
2D/1V
AP
1V
2D /1
V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
AP
2D /1
V
2D/1V
1V
2D/1V
2D/1V
2D/1V
AP
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
AP
AP
1D
AP
2D/1V 2D/1V
2D/1V
2D/1V
1V 1V
AP
2D/1V
2D/1V
2D/1V 2D/1V1V
1V2D/1V
2D/1V
AP
2D/1V
AP
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V AP
2D/1V
2D /1
V
2D/1V
1V
2D/1V
2D/1V
AP
2D/1V
2D/1V
AP
2D/1V
2D/1V
2D/1V 2D/1V2D/1V
2D/1V
2D/1V
2D/1V
1V
AP
AP
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
2D/1V 2D/1V
2D/1V
2D/1V
2D/1V
2D/1V
CC
CC
CC
CC
E M
E
E M
E
(E)
(E)
K
AP
CC
EM
T
2D/1V
2D/1V 2D/1V1V
2D/1V
CC
E M
E M
EM
EM
E M
E M
EM
RX
DCEL
K
K
EM (E)
EM (E)
EM (E) AP
CC
E M
E M
E M
EM
T
2D/1V
CCD
C
E S
R X
K
EM
E M
EM
E M
E M
E M
031-EP100
031-EP100
031-EP100
031-EP100
ELECT. ROOM
G-500C
TR
G-500D
MAIN ELECT. ROOM
242G
TR
G-328
ELECT ROOM
G-217B
TELE CLOS
G-217A
TR
G-202
ELECT. ROOM
G-147
TELE CLOSET
G-132
ELECT. ROOM
G-122
ELECT. ROOM
G160G
(E) (B31) GB
(E) GA
(E) GIS
(E) (B31) GCRA
(E) (B31) EPBB
(E) PBA
(E) EPBA
(E) RBA
(E) RBB(E) BX
(E) BX2
(E) BR
(E) EBN
(E) 1F(E) 1G
(E) (B31) BW SEC
ODU-2
ODU-1
ODU-1
(B31) 1CR1A - 6,8
(B31) 1CR1A - 7,9
(E) (B31) EPBB - 12,14
ODU-1
(E) (B31) GCRA - 24,26
APPROXIMATE LOCATION OF
PANELBOAR "(E) 31CRDP1" ON
FLOOR BELOW.
C1 C1
IDU-2TR
G-500D
Elect. Room
G-500C
(E) (B31) GEQ2
(E) (B31) GC
(E) (B31) GD
(E) (B31) 31PDP1
(E) (B31) GEQ2 - 42,44,46 (E) (B31)
GEQ2-43(E) (B31)
GEQ2-43
ODU-2
(E) (B31) GEQ2 - 45,47
(E) (B31) GD - 21,23,25
C1
C1
C1
C1
CT Power Equipment
G-345G
(E) (B31)
GEQ2-43
(E) (B31)
GEQ2-43
(E) (B31)
GEQ2-43
(E) (B31)
GEQ2-43
(E) (B31) GEQ2 - 48,50,52
(E) (B31) GD - 22,24,26
(E) (B31) GEQ2 - 49
(E) (B31) GEQ2 - 49
(E) (B31) GEQ2 - 49
(E) (B31) GEQ2 - 49
(E) (B31) GEQ2 - 49(E) (B31) GEQ2 - 49
IDU-1 10
ODU-1
(E) (B31) GEQ2 - 51,53
C1
C1
(E) (B31) BW SEC 2 - 17,19,21 (E) (B31) EPBB - 2,4,6
IDU-2
ODU-2
(E) (B31) EPBB - 8,10
C1
C1
(E) (B31) GB (E) GA
(E) GIS (E) (B31) GCRA
(E) (B31) GB - 23,25,27
(E) (B31) GCRA - 29,31,33
(E) (B31) GCRA - 13 (E) (B31) GCRA - 13
(E) (B31) GCRA - 13
(E) (B31) GCRA - 13
(E) (B31) GCRA - 13
IDU-2
C1
C1
(E) (B31)
GCRA-15
(E) (B31)
GCRA-15
(E) (B31)
GCRA-15
(E) (B31)
GCRA-15
12 12
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e
V A
E
H R
M /F
F E
C h ill ic o th e
E H
R M
M
E P rv t
/1
/2
:1
:4
P M
031-EP100
ELECTRICAL PLAN - GROUND
FLOOR
07/07/2023 JB CLG
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OH
BID DOCUMENTS
CHILLICOTHE
VAMC
Approved: Owner
1/16" = 1'-0"
BLDG 31 - OVERALL GROUND - ELECTRICAL NEW WORK PLAN
1/4" = 1'-0"
BLDG - TR G500D - ELECTRICAL NEW WORK PLAN
1/4" = 1'-0"
BLDG 31 - TR G345G - ELECTRICAL NEW WORK PLAN
1/4" = 1'-0"
BLDG - TR G202 / G204 - ELECTRICAL NEW WORK PLAN
1/4" = 1'-0"
BLDG - TR G182B - ELECTRICAL NEW WORK PLAN
D R A W I N G N O T E S :
1 PROVIDE (2) L21-20R RECEPTACLES. MOUNT ABOVE DATA RACK ON SIDE OF CABLE TRAY.
2 INSTALL NEW BUSBAR GROUNDING ELECTRODE. (TGB) THE BONDING CONDUCTOR SHALL BE COPPER, STRANDED OR SOLID IN CONDUIT AND SHALL BE RUN IN AS STRAIGHT A LINE AS PRACTICABLE. (1/0 CU). THE BONDING CONDUCTOR SHALL BE CONNECTED TO THE INTERSYSTEM BONDING TERMINATION. (1/0 CU). IF NO INTERSYSTEM BONDING TERMINATION EXISTS, CONNECT TO THE GROUNDED INTERIOR METAL WATER PIPING SYSTEM, WITHIN 1.5 M (5 FT) FROM
ITS POINT OF ENTRANCE TO THE BUILDING.
3 PROVIDE (2) L21-30R RECEPTACLES. MOUNT ON TOP OF NEW DATA RACK. CIRCUIT TO EMERGENCY POWER CIRCUIT
MAINTAINED FROM DEMO PHASE.
4 CIRCUIT TO EXISTING EMERGENCY RECEPTACLE CIRCUIT IN THIS ROOM.
5 CIRCUIT NEW TR LIGHTING FIXTURES TO LOCAL LIGHTING CIRCUIT MAINTAINED DURING DEMOLITION.
6 CIRCUIT NEW RECEPTACLES TO EMERGENCY PANEL.
7 INSTALL NEW KEY PAD / CARD READER, DOOR CONTACT, ELECTRIC STRIKE, AND MOTION SENSOR TO DOOR.
8 INSTALL NEW 8 DOOR SYMMETRY PACS PANEL CONTROLLER AND POWER SUPPLY.
9 CIRCUIT INDOOR UNIT TO ASSOCIATED CONDENSING UNIT LOCATED OUTSIDE, BEYOND OUTSIDE WALL OF BUILDING ON
GROUND LEVEL.
10 CIRCUIT INDOOR CASSETTE UNIT TO OUTDOOR CONDENSER. PROVIDE DISCONNECT SWITCH MOUNTED UP HIGH NEXT
TO CASSETTE UNIT.
11 INSTALL NEW 120V 30A HEAVY DUTY NON-FUSED DISCONNECT AND FEED (2)#12, #12 GROUND, 3/4"C TO SPLIT SYSTEM
UNIT MOTOR.
12 CIRCUIT TO LOCAL RECEPTACLE CIRCUIT IN THIS ROOM.
No. Revisions: Date:
BID DOCUMENTS 07/07/2023
1 ADDENDUM #1 10/30/2023
2 ADDENDUM #2 12/11/2023
| Sheets |
| 031-EP100 - ELECTRICAL PLAN - GROUND FLOOR |
File details come from the government source that posted it. Updated .