S06 - Amendment 0007 Att 16 - 026-TN100 - BASEMENT PLAN -TECHNOLOGY.pdf

PDF 311 KB Posted

Attached to
Y1DA--538-21-701 EHRM Infrastructure Upgrades Construction Chillicothe, OH (VA-23-00066755)
Solicitation number
36C77623B0058
Issued by

About this file

This basement plan drawing depicts the technical infrastructure upgrades for the EHRM project at the Chillicothe VA Medical Center in Chillicothe, Ohio. Key details include: the drawing shows the proposed locations for new telecom rooms, equipment racks, cable pathways between rooms through conduit and cable tray, as well as notes on cable termination and protection. The related federal contract opportunity is a solicitation from the VA Technology Acquisition Center for construction services to implement the infrastructure upgrades depicted in the basement plan drawing. The period of performance and response date are not specified.

View the file

Other files

File Type Posted
Abstract of offers - Chillicothe Bid Opening 01172024 signed.pdf PDF
S06 - Amendment 0009 Bid Opening.pdf PDF
S06 - Amendment 0008 Extend due date to 01172024.pdf PDF
S06 - 36C77623B0058 0007.pdf PDF
S06 - Amendment 0007 Att 10 - 14.063_024-EP100 - ELECTRICAL PLAN - BASEMENT FLOOR.pdf PDF
S06 - Amendment 0007 Att 13 - 14.116_E616.31 - PANELBOARD SCHEDULES.pdf PDF
S06 - Amendment 0007 Att 4 - Chiillicothe VA Lead Paint Survey Report.pdf PDF
S06 - Amendment 0007 Att 7 - 000-TS100 - CAMPUS TECHNOLOGY SITE PLAN.pdf PDF
S06 - Amendment 0007 Att 6 - 000-TN500 - TECHNOLOGY DETAILS.pdf PDF
S06 - Amendment 0007 Att 3 - 2023-01 AHERA.pdf PDF
S06 - Amendment 0007 Att 11 - 14.077_031-EP100 - ELECTRICAL PLAN - GROUND FLOOR.pdf PDF
S06 - Amendment 0007 Att 14 - 018-TN209 - TECHNOLOGY ENLARGEMENT.pdf PDF
S06 - Amendment 0007 Att 8 - 13.038_030-MD101 - MECHANICAL DEMOLITION PLAN - FIRST FLOOR.pdf PDF
S06 - Amendment 0007 Att 12 - 14.080_035-EP100 - ELECTRICAL PLAN - BASEMENT.pdf PDF
S06 - Amendment 0007 Att 1 Technical questions Round 2 responses.pdf PDF
S06 - Amendment 0007 Att 2 - Final SWP3.pdf PDF
S06 - Amendment 0007 Att 15 - 018-TN210 - TECHNOLOGY ENLARGEMENT.pdf PDF
S06 - Amendment 0007 Att 5 - 000-TN400 - TECHNOLOGY RISER DIAGRAMS.pdf PDF
S06 - Amendment 0007 Att 9 - 14.062_023-EP101 - ELECTRICAL PLAN - FIRST FLOOR.pdf PDF
Amendment 0006 36C77623B0058.pdf PDF
Amendment 0005 36C77623B0058.pdf PDF
Amendment 0005 - Attachment Addendum 1.zip ZIP file
Amendment 0005 - Attachment - Vendor Questions_Responses final.pdf PDF
Amendment 0004 36C77623B0058.pdf PDF
Amendment 0003 36C77623B0058.docx DOCX document
Att 10 Volume 10 - Technology_Combined.pdf PDF
Att 8 Volume 8 - Electrical_Combined.pdf PDF
Att 6 Volume 6 - Mechanical_Combined.pdf PDF
Att 9 Volume 9 - Electrical_Combined.pdf PDF
Att 13 Volume 13 - Fiber_Combined.pdf PDF
Att 4 Volume 4 - Architectural_Combined.pdf PDF
Att 5 Volume 5 - Fire Suppression_Combined.pdf PDF
Att 14 S04 - Site Visit sign in 10-11-2023.pdf PDF
Att 7 Volume 7 - Mechanical_Combined.pdf PDF
Att 12 Volume 12 - Fiber_Combined.pdf PDF
Att 11 Volume 11 - Technology_Combined.pdf PDF
Att 3 Volume 3 - Architectural_Combined.pdf PDF
Att 2 Volume 2 - Civil_Combined (1).pdf PDF
36C77623B0058 0002.docx DOCX document
Att 1 Volume 1 - General and Civil_Combined.pdf PDF
DBA Wage Rates Construction - Ross Cty.pdf PDF
36C77623B0058 0001.docx DOCX document
Attachment 04 - DBA Wage Determination.pdf PDF
Updated _Specifications_Combined.pdf PDF
Attachment 08 - SOW attach Volume 1 Part 3.pdf PDF
Attachment 09 - SOW attach Volume 1 Part 4.pdf PDF
Attachment 04 - Wage Rate Determination - Chillicothe.pdf PDF
Attachment 11 - SOW attach Volume 1 Part 6.pdf PDF
Attachment 19 - SOW attach Volume 3 Part 4.pdf PDF
Attachment 17 - SOW attach Volume 3 Part 2.pdf PDF
Show 40 more

Latest 50 of 65 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Offices

4C

Offices

4B

Recreation Clinic

Stair

S1-0

Toilet

4A

Elect. Room

Corridor

32A

Storage

HAC

Linen

Stair

S2-0 Linen Storage

Office

Office

CIO

Elevator Equipment

Mechanical

Equipment

9A

Tele Clos

27A

Electric Switch Gear

Office

Corridor

XXX

Mech.

Office

Office

25A

Toilet

Electrical

EMS

23A

Office

Office

Toilet

28Toilet

HAC

Office

18A

Office

18B

Office

18C

Office

18D

Office

18E

Office

18F

Office

18G

Office

18H

Office

18I

Stair

S3-0

Stair

S4-0

Stair

S5-0

EMS EQUIPMENT

24A

Chapel

Storage

2A

Corridor

Corridor

Office

4D

200L

Room

200M

(2) 4"C - (3) 24-STRAND OS2 OPTICAL FIBER

AND (3) 25-PAIR COPPER CABLES AND (1)

4"C - SPARE

B

HAND HOLE

(1) 4"C - (3) 24-STRAND OS2 OPTICAL

FIBER CABLE AND (1) 4"C - SPARE

(1) 4"C - (1) 24-STRAND OS2

OPTICAL FIBER CABLE

(2) 4"C - (1) 24-STRAND OS2

OPTICAL FIBER CABLE AND

25-PAIR COPPER CABLE

HAND HOLE

A

OUTLINE OF TR #200

AT FLOOR ABOVE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/T

.0

V A

-C h ill ic o th e B

C

.r v t

/1 /2

:3

:0

P M

026-TN100

BASEMENT PLAN - TECHNOLOGY

07/07/2023 ACA ECW

EHRM INFASTRUCTURE UPGRADES 538-21-701

CHILLICOTHE, OHIO

BID DOCUMENTS

VA STATION NO:

Approved: Client Name

GENERAL NOTES:

1. THE DIAMOND DIAGRAM SHOWN CONSIST OF AN 80 METER LINE

DRAWN TO FLOOR PLAN SCALE IN FOUR DIRECTIONS FROM CENTER

OF TELECOM ROOM (TR) WITH LINES CONNECTING THE FOUR

ENDPOINTS.

2. EACH DIAMOND DIAGRAM REPRESENTS AN OUTLINE OF THE

HORIZONTAL CABLE DISTANCE LIMITATION FROM EACH TR.

1/8" = 1'-0"

BASEMENT PLAN - TECHNOLOGY

KEY NOTES:

1. PROVIDE PENETRATION THRU EXTERIOR WALL OF CRAWL SPACE

AND ROUTE CONDUITS IN CRAWL SPACE BELOW BASEMENT FLOOR

OVER TO LOCATION INDICATED.

2. PROVIDE PENETRATION THRU CEILING OF CRAWL SPACE AND

ROUTE CONDUITS UP TO ABOVE BASEMENT CEILING AND OVER TO

TR.

3. PROVIDE PULLBOX ABOVE CEILING AND ROUTE CONDUITS TO

LOCATIONS INDICATED. PROVIDE PENETRATION THRU CEILING AND

ROUTE CONDUITS TO FLOOR ABOVE.

4. PROVIDE RACK MOUNTED ANALOG PRIMARY CIRCUIT PROTECTION

"SC-SPR-1" AND "PATCH PANEL "SC-MPP-1" FOR TERMINATION OF

NEW COPPER BACKBONE CABLES IN MDF #27. REFER TO "018-TN205"

FOR CABLE CONNECTION REQUIREMENTS.

5. TRANSITION COPPER BACKBONE CONDUIT TO (RMC) FOR ROUTE

THRU BUILDING TO TELECOM ROOM (MDF).

No. Revisions: Date:

BID DOCUMENTS 07/07/2023

1 Addendum 2 12/11/2023

File details come from the government source that posted it. Updated .