This document provides details for a federal contract opportunity to provide EHRM Infrastructure Upgrades Construction for the Department of Veterans Affairs in Chillicothe, Ohio. The solicitation number is 36C77623B0058 and seeks to award a contract to support upgrading infrastructure at the Chillicothe VA medical center including installing new fiber cabling as indicated by the related 11MB file titled "Att 12 Volume 12 - Fiber_Combined.pdf". Responses are due by the date listed on the Solicitation Number Y1DA--538-21-701 posted by the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas. The opportunity type is listed as a Solicitation and additional details on required products, services, pricing, response dates, or terms are not provided in this high-level summary document.
View the file
Other files
Show 40 more
Latest 50 of 65 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N
N
CHILLICOTHE VA MEDICAL CENTER
PROJECT NUMBER: 538-21-701
DEPARTMENT OF VETERANS AFFAIRS
273 STATE ROUTE 104, CHILLICOTHE, OHIO 45601
EHRM INFRASTRUCTURE UPGRADES
SHEET NAMING EXAMPLE:
BUILDING NUMBER
DISCIPLINE
SHEET TYPE
FLOOR NUMBER
ZONE LOCATION ON FLOOR
100-AE101.1
G E N E R A L N O T E S
A. SEE GENERAL PROJECT NOTES FOR NEW WORK FOR ADDITIONAL REQUIREMENTS FOR WORK WITHIN THE
EXISTING FACILITY. THE CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND FIELD CONDITIONS
PRIOR TO DEMOLITION AND CONSTRUCTION. IF PROVIDED, THE GENERAL CONTRACTOR SHALL EXAMINE
EXISTING BUILDING DOCUMENTS. THE CONTRACTOR SHALL BRING ANY DISCREPANCIES TO THE
IMMEDIATE ATTENTION OF THE C.O.R. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF
EXISTING ITEMS TO REMAIN DURING DEMOLITION AND CONSTRUCTION. MAINTAIN EXIT EGRESS PATHS
TO EXISTING EXIT DOORS DURING CONSTRUCTION.
B. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL CONSTRUCTION ROUTES BEYOND THE
AREAS OF WORK AND THE ROUTES MUST BE RETURNED TO THEIR ORIGINAL CONDITION AT THE END OF
THE PROJECT.
C. ALL DEMOLITION AND CONSTRUCTION ACTIVITIES SHALL BE COORDINATED WITH THE C.O.R. TO MINIMIZE
DISRUPTIONS OF NORMAL FUNCTIONS OF THE VA'S OCCUPIED AREAS.
D. IF CONSTRUCTION NOISE IS ANTICIPATED, SUBMIT A WRITTEN REQUEST TO THE C.O.R. FOR THE
SCHEDULED TIME OF THE CONSTRUCTION ACTIVITIES. NO WORK SHALL BE DONE WITHOUT THE WRITTEN
APPROVAL OF THE C.O.R. THE C.O.R. RESERVES THE RIGHT TO DISCONTINUE NOISY CONSTRUCTION AT
ANY TIME. NO RADIOS SHALL BE PERMITTED AT ANY TIME IN WORK AREAS ADJACENT TO OCCUPIED
SPACES.
E. ALL EXISTING SERVICES AND UTILITIES SHALL BE MAINTAINED TO AREAS THAT ARE IN OPERATION AND
SERVED BY THEM. COORDINATE ALL DISRUPTIONS OR DISCONTINUATIONS OF UTILITIES AND SERVICES
WITH C.O.R. NO SHUT DOWN OF EXISTING SERVICES IS ALLOWED TO OCCUR UNTIL RECEIVING THE
C.O.R.'S WRITTEN APPROVAL OF THE SHUT DOWN SCHEDULE. PROVIDE TEMPORARY SERVICES AND/OR
UTILITIES DURING INTERRUPTIONS AS REQUIRED AND APPROVED BY THE C.O.R.
F. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PREVENT DAMAGE TO THE V.A.'S
AREAS ADJACENT TO NEW CONSTRUCTION OR AREAS WHERE VARIOUS SYSTEM CONNECTIONS OR
EXTENSIONS ARE REQUIRED. IN THESE AREAS, THE CONTRACTOR IS RESPONSIBLE FOR DAMAGE
CAUSED BY LACK OF SUFFICIENT PROTECTION FROM THE WEATHER AND FROM THE RESULTS OF ALL
CONSTRUCTION ACTIVITY INCLUDING BUT NOT LIMITED TO DUST AND WATER.
G. THE CONTRACTOR SHALL RECEIVE WRITTEN APPROVAL FROM THE C.O.R. BEFORE USING OPEN FLAMES, WELDING RODS AND TORCHES. THE CONTRACTOR IS RESPONSIBLE FOR ALL MEANS AND METHODS TO
PROHIBIT THE MIGRATION OF SMOKE AND OTHER PRODUCTS OF COMBUSTION INTO OCCUPIED AREAS OF
THE EXISTING BUILDING AND FOR OBTAINING ALL REQUIRED PERMITS RELATED TO HOT WORK.
H. DO NOT OVERLOAD THE EXISTING BUILDING STRUCTURE. MAINTAIN THE STRUCTURAL INTEGRITY OF ALL
STRUCTURAL FRAMING MEMBERS AND SYSTEMS AT ALL TIMES.
I. ALL DEMOLISHED MATERIAL, EXCEPT MATERIAL THAT IS LISTED OR MARKED FOR RETENTION, SHALL
BECOME THE PROPERTY OF THE CONTRACTOR AND IT SHALL BE DISPOSED OF. NO DEBRIS RESULTING
FROM WORK SHALL BE LEFT IN THE CONSTRUCTION ROUTES BEYOND THE AREAS OF WORK.
J. REMOVAL OF A PARTICULAR ITEM IS TO INCLUDE ALL RELATED ITEMS, SUCH AS REMOVAL OF WALLS
WOULD INCLUDE ASSOCIATED DOORS, HARDWARE, ELECTRICAL, PLUMBING, MECHANICAL, ETC. REFER
TO DEMOLITION DRAWINGS FOR MORE INFORMATION. FOR ALL REMOVALS, THE GENERAL CONTRACTOR
AND SUBCONTRACTORS SHALL COORDINATE WITH ALL OTHER DISCIPLINES.
K. THE CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT FOR ITEMS NOT DEMOLISHED OR REMOVED
AS REQUIRED UNTIL PERMANENT SUPPORT IS PROVIDED IN THE FINAL CONSTRUCTION.
L. ALL OPENINGS IN EXISTING WALLS, CEILINGS AND FLOORS, WHICH ARE THE RESULT OF REMOVALS AND
OTHER NEW CONSTRUCTION ACTIVITY, SHALL BE PATCHED WITH NEW MATERIALS THAT MATCH THE
EXISTING MATERIALS OR AS NOTED ON DRAWINGS. IF THE PATCH IS TO BE MADE IN FIRE RATED
CONSTRUCTION, THE PATCH MUST ACHIEVE THE REQUIRED FIRE RATING. THE PATCH SHALL BE FINISHED
TO A LIKE NEW CONDITION TO MATCH THE EXISTING FINISH.
M. ALL EXISTING OPENINGS IN CEILINGS, FLOORS AND WALLS DISCOVERED IN THE EXISTING STRUCTURE
SHALL BE PATCHED WITH NEW MATERIALS THAT MATCH THE EXISTING MATERIALS. IF THE PATCH IS TO
BE MADE IN FIRE RATED CONSTRUCTION, THE PATCH MUST ACHIEVE THE REQUIRED FIRE RATING. THE
PATCH SHALL BE FINISHED TO A LIKE NEW CONDITION TO MATCH THE EXISTING FINISH.
N. WHERE EXISTING SURFACES ARE TO BE REFINISHED OR ARE TO SERVE AS SUBSTRATE FOR THE
ATTACHMENT OR APPLICATION OF NEW MATERIALS OR CONSTRUCTION, PREPARE OR ALTER THE
EXISTING SURFACES AS NECESSARY TO PROPERLY ACCOMMODATE THE NEW MATERIALS.
O. FIELD VERIFY SIZES AND DIMENSIONS OF ALL EXISTING UTILITIES THAT IMPACT THE NEW WORK.
DETERMINE THE SIZE AND LOCATION THE PENETRATIONS FROM THE EXISTING UTILITIES WITHIN THE NEW
WORK. SEAL TIGHT TO ALL PENETRATIONS AND CAULK.
P. PENETRATIONS THROUGH EXISTING FIRE RATED CONSTRUCTION MUST BE PROPERLY CLOSED AND FIRE
SAFE'D TO ACHIEVE THE REQUIRED FIRE RATING BY THE END OF CONSTRUCTION OPERATIONS FOR EACH
DAY.
Q. NEW HOLES IN EXISTING ROOF STRUCTURES FOR NEW WORK MUST BE COORDINATED WITH THE
EXISTING STRUCTURE SO THAT CRITICAL STRUCTURAL MEMBERS ARE NOT DAMAGED.
R. UNLESS OTHERWISE NOTED, THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISTING
SALVAGED STOCK BEFORE ORDERING NEW MATERIAL.
E X I S T I N G F A C I L I T I E S:
A. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND FEDERAL AUTHORITIES, CODES, RULES AND REGULATIONS.
B. THESE DOCUMENTS SHOW THE MINIMUM CONSTRUCTION REQUIREMENTS AND THE MINIMUM QUALITY OF
WORK EXPECTED. MORE STRINGENT REQUIREMENTS STIPULATED WITHIN RELEVANT MANUFACTURER’S
INSTALLATION INSTRUCTIONS WILL SUPERSEDE.
C. ANY UNFORESEEN OR UNCLEAR CONDITIONS SHALL BE REPORTED TO THE C.O.R. PRIOR TO PROCEEDING
WITH WORK.
D. ANY CONFLICTS WITHIN THE DRAWINGS, BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, OR
BETWEEN THE DRAWINGS AND THE ACTUAL CONDITIONS AT THE SITE, ARE TO BE BROUGHT TO THE
IMMEDIATE ATTENTION OF THE C.O.R. THE CONTRACTOR SHALL NOT PROCEED WITH WORK UNTIL
WRITTEN CLARIFICATION FROM THE ARCHITECT/ENGINEER IS RECEIVED.
E. UNLESS OTHERWISE NOTED, ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED PER THE APPLICABLE
PROVISIONS OF THESE DOCUMENTS AND THE MANUFACTURER’S INSTRUCTIONS.
F. ALL MATERIALS USED SHALL BE NEW UNLESS OTHERWISE NOTED AND/OR OF A QUALITY TO MEET OR
EXCEED ALL APPLICABLE INDUSTRY STANDARDS. WHERE SPECIFIED PRODUCTS OR MANUFACTURERS
ARE NOT NOTED, THE CONTRACTOR IS REQUIRED TO NOTIFY THE ARCHITECT TO OBTAIN A MINIMUM
STANDARD OF QUALITY.
G. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL MEANS, METHODS AND TECHNIQUES FOR
CONSTRUCTION.
H. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR JOB-SITE SAFETY INCLUDING THE ADHERENCE TO
OSHA REGULATIONS.
I. ALL ELECTRICAL AND MECHANICAL WORK SHALL BE PERFORMED BY PERSONNEL LICENSED IN THE STATE
WHERE THIS PROJECT IS LOCATED.
J. REMOVE ALL DEBRIS PROPERLY FROM THE SITE. LOAD DEBRIS DIRECTLY ONTO TRUCKS FOR REMOVAL.
DISPOSE OF DEBRIS LEGALLY. DO NOT BURN DEBRIS ON THE SITE. DO NOT ALLOW DEBRIS TO ENTER
SEWERS. DO NOT ALLOW PILED DEBRIS TO ENDANGER STRUCTURES, BLOCK EXISTS OR ROADWAYS.
COMBUSTIBLE WASTE WHICH COULD CREATE A FIRE HAZARD SHALL NOT BE PERMITTED TO ACCUMULATE
IN OR AROUND THE CONSTRUCTION SITE.
K. COORDINATE ALL WORK WITH ALL OTHER DISCIPLINES, INCLUDING, EXACT SIZE AND LOCATION OF ALL
ROOF AND FLOOR OPENINGS SHOWN ON ARCHITECTURAL DRAWINGS SHALL BE VERIFIED WITH THE
ASSOCIATED SUB-CONTRACTORS PRIOR TO CONSTRUCTION.
L. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL GOVERN. ALL PLAN DIMENSIONS ARE TAKEN TO FINISH
FACE OF CONSTRUCTION.
M. ALL CONCEALED WOOD SHALL BE FIRE RETARDANT TREATED.
N. SEAL CONSTRUCTION TIGHT TO ALL PENETRATIONS AND APPLY SEALANT.
O. ALL PENETRATIONS THROUGH FIRE RATED CONSTRUCTION MUST BE FIRE SAFE'D IN ACCORDANCE WITH
THE SPECIFICATIONS. IF FLOOR OR RATED WALL PENETRATIONS CANNOT BE FIRESTOPPED AT THE END
OF THE WORK SHIFT DUE TO THE NEED TO PULL ADDITIONAL CABLES, TEMPORARY FIRESTOPPING
COMPOSED OF MINERAL WOOL SHOULD BE INSTALLED IN THE PENETRATION TO PROVIDE PROTECTION
AGAINST FIRE/SMOKE SPREAD THROUGH THE UNSEALED PENETRATION.
P. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL EQUIPMENT INSTALLATION AND VERIFYING
ALL REQUIRED ROUGH OPENINGS, AND ROUGH-IN DIMENSIONS WITH THE EQUIPMENT MANUFACTURER, AND C.O.R. PRIOR TO CONSTRUCTION.
Q. REFER TO SHEET AE601 FOR SCHEDULES AND PARTITION TYPES.
N E W W O R K:
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:3
:4
P
M
GI000.12
COVER SHEET - VOL. 12
07/07/2023 PQ JF
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
BID DOCUMENTS - 100%
CAMPUS
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
VOLUME 12 OF 13
N.T.S.Scale:
CAMPUS MAP
N.T.S.Scale:
VICINITY MAP
No. Revisions: Date:
BID DOCUMENTS 07/07/2023
SHEET INDEX
GENERAL
GI000.12 COVER SHEET - VOL. 12
SHEET INDEX
TELECOMMUNICATION
000-TN000 TECHNOLOGY COVERSHEET
000-TN400 TECHNOLOGY RISER DIAGRAMS
000-TN500 TECHNOLOGY DETAILS
000-TS100 CAMPUS TECHNOLOGY SITE PLAN
001-TN100 BASEMENT PLAN - TECHNOLOGY
001-TN101 LEVEL 01 PLAN - TECHNOLOGY
001-TN102 LEVEL 02 PLAN - TECHNOLOGY
003-TN100 BASEMENT PLAN - TECHNOLOGY
003-TN101 LEVEL 01 PLAN - TECHNOLOGY
007-TN100 BASEMENT PLAN - TECHNOLOGY
007-TN101 LEVEL 01 PLAN - TECHNOLOGY
009-TN100 BASEMENT PLAN - TECHNOLOGY
009-TN101 LEVEL 01 PLAN - TECHNOLOGY
009-TN102 LEVEL 02 PLAN - TECHNOLOGY
018-TD101 LEVEL 01 DEMOLITION PLAN - TECHNOLOGY
018-TN100 BASEMENT PLAN - TECHNOLOGY
018-TN101 LEVEL 01 PLAN - TECHNOLOGY
018-TN102 LEVEL 02 PLAN - TECHNOLOGY
018-TN200 DATA CENTER #122 PATHWAY LAYOUT - TECHNOLOGY
018-TN201 DATA CENTER #122 PHASE 1 PLAN - TECHNOLOGY
018-TN202 DATA CENTER #122 PHASE 2 PLAN - TECHNOLOGY
018-TN203 DATA CENTER #122 PHASE 3 PLAN - TECHNOLOGY
018-TN204 DATA CENTER #122 PHASE 4 PLAN - TECHNOLOGY
018-TN205 COPPER BACKBONE EQUIPMENT DETAIL
018-TN206 DATA CENTER STRUCTURED CABLING SYSTEM DIAGRAM
018-TN207 FIBER BACKBONE RISER-CORE A
018-TN208 FIBER BACKBONE RISER-CORE B
020-TN101 LEVEL 01 PLAN - TECHNOLOGY
020-TN102 LEVEL 02 PLAN - TECHNOLOGY
020-TN103 LEVEL 03 PLAN - TECHNOLOGY
021-TN101 LEVEL 01 PLAN - TECHNOLOGY
021-TN102 LEVEL 02 PLAN - TECHNOLOGY
023-TN100 BASEMENT PLAN - TECHNOLOGY
023-TN101 LEVEL 01 PLAN - TECHNOLOGY
024-TN100 BASEMENT PLAN - TECHNOLOGY
024-TN101 LEVEL 01 PLAN - TECHNOLOGY
024-TN102 LEVEL 02 PLAN - TECHNOLOGY
024-TN103 LEVEL 03 PLAN - TECHNOLOGY
025-TN100 BASEMENT PLAN - TECHNOLOGY
025-TN101 LEVEL 01 PLAN - TECHNOLOGY
026-TN100 BASEMENT PLAN - TECHNOLOGY
026-TN101 LEVEL 01 PLAN - TECHNOLOGY
026-TN102 LEVEL 02 PLAN - TECHNOLOGY
026-TN103 LEVEL 03 PLAN - TECHNOLOGY
027-TN100 BASEMENT PLAN - TECHNOLOGY
027-TN101 LEVEL 01 PLAN - TECHNOLOGY
027-TN102 LEVEL 02 PLAN - TECHNOLOGY
027-TN103 LEVEL 03 PLAN - TECHNOLOGY
028-TN100 BASEMENT PLAN - TECHNOLOGY
028-TN101 LEVEL 01 PLAN - TECHNOLOGY
028-TN102 LEVEL 02 PLAN - TECHNOLOGY
030-TN100 BASEMENT PLAN - TECHNOLOGY
030-TN101 LEVEL 01 PLAN - TECHNOLOGY
030-TN102 LEVEL 02 PLAN - TECHNOLOGY
030-TN103 LEVEL 03 PLAN - TECHNOLOGY
TECHNOLOGY SYMBOL LIST
SYMBOL: DESCRIPTION: NOTE:
EQUIPMENT
LIST ABBREV.:
TECHNOLOGY ABBREVIATION KEY
ENTRANCE FACILITYEF-#
MAIN CROSS-CONNECTMC-#
TELECOMMUNICATIONS ROOMTR-#
ABOVE FINISHED FLOORAFF
BELOW FINISHED CEILINGBFC
CONDUITC
SIMILARSIM
TYPICALTYP
MOUNTING HEIGHT ABOVE FINISHED FLOOR+#
JUNCTION BOXJ-BOX
ABBR: DESCRIPTION:
UNLESS OTHERWISE NOTEDUON
FIELD OF VIEWFOV
DOUBLE POLE DOUBLE THROWDPDT
PAN TILT ZOOMPTZ
POWER OVER ETHERNETPOE
ABOVE FINISHED GRADEAFG
DELAYED EGRESSDE
TECHNOLOGY GENERAL NOTES:
1. ##-###-# INDICATES TECHNOLOGY EQUIPMENT SCHEDULE ITEM LABELED AS "EQUIPMENT
LIST ABBREVIATION"
2. REFER TO TECHNOLOGY EQUIPMENT SCHEDULE AND SPECIFICATIONS FOR FULL
DESCRIPTIONS AND MANUFACTURERS OF ALL DEVICES.
TECHNOLOGY MOUNTING SUBSCRIPT KEY:
A MOUNT AT +6" TO CENTERLINE ABOVE COUNTER OR BACKSPLASH
H MOUNT ORIENTED HORIZONTALLY
L MOUNT IN CASEWORK
M MOUNT IN MODULAR FURNITURE
S MOUNT IN SURFACE RACEWAY
A SLASH IS USED BETWEEN TWO SUBSCRIPTS, E.G., A/H.
1. THE LOCATION OF THE CONDUIT, HAND HOLES AND/OR MAINTENANCE HOLES SHOWN ARE
APPROXIMATE LOCATIONS. FIELD VERIFY THE LOCATION OF ALL UTILITIES PRIVATE AND/OR
PUBLIC PRIOR TO THE INSTALLATION OF THE COMPONENT. FIELD COORDINATE THE FINAL
LOCATION WITH THE OWNER AND ENGINEER PRIOR TO INSTALLATION.
2. POTHOLING TO LOCATE EXISTING UNDERGROUND UTILITIES, IF APPLICABLE, SHALL BE
INCLUDED IN THE CONTRACTOR'S BID. CONTRACTOR IS RESPONSIBLE FOR FINAL
PLACEMENT OF HAND HOLES AND/OR MAINTENANCE HOLES AND SHALL NOTIFY THE
ENGINEER OF FINAL LOCATIONS PRIOR TO INSTALLATION.
3. HAND HOLES AND/OR MAINTENANCE HOLES SHALL BE CONSTRUCTED SO THAT THE TOP OF
THE FRAME WILL BE FLUSH WITH THE GROUND LINE.
4. REMOVAL AND REPLACEMENT OF THE EXISTING UNDERGROUND UTILITIES THAT ARE
REQUIRED TO COMPLETE THE INSTALLATION SHALL BE INCLUDED IN THE CONTRACTOR'S
BID.
5. CONTRACTOR SHALL INCLUDE IN THEIR BID ANY REMOVAL AND REPLACEMENT OF EXISTING
SIDEWALK, PAVEMENT, GRASS, SHRUBS, TREES, ETC. THAT WILL BE IMPACTED BY THE
INSTALLATION OF THE NEW CONDUITS SHOWN ON THE DRAWINGS. IF TREES ARE REQUIRED
TO BE REMOVED THE CONTRACTOR SHALL CONTACT THE OWNER AND DISCUSS OPTIONS
PRIOR TO CUTTING DOWN ANY TREE OR SHRUB OVER 5' IN HEIGHT.
6. NO ADDITIONAL COST SHALL BE APPROVED FOR PLACING CONDUITS DEEPER THAN
REQUIRED MINIMUM DEPTH TO AVOID EXISTING UNDERGROUND UTILITIES.
7. PROVIDE A MINIMUM OF 25'-0" SLACK LOOP WITHIN EACH HAND HOLES AND/OR
MAINTENANCE HOLES. SLACK LOOP SHALL BE SECURE SO COPPER OR FIBER IS NOT
RESTING ON EARTH AFTER FINAL INSTALLATION.
TECHNOLOGY OUTSIDE PLANT NOTES
1. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE ADA STANDARDS FOR
ACCESSIBLE DESIGN. REFER TO THE ADA GUIDELINES FOR ALL CONFIGURATION DETAILS
ON THIS PAGE FOR ADDITIONAL INFORMATION.
2. CONCEAL ALL CONDUIT IN WALLS, PARTITIONS, ABOVE CEILING, IN FLOOR SLAB, ETC.
UNLESS OTHERWISE INDICATED ON THE PLANS OR IN THE SPECIFICATIONS. CONDUIT IN
MECHANICAL ROOMS AND STORAGE ROOMS WITHOUT CEILINGS MAY BE EXPOSED ON
BUILDING STRUCTURE.
3. BOXES LOCATED ON OPPOSITE SIDES OF NON-RATED WALLS SHALL BE OFFSET A MINIMUM
OF 6" HORIZONTALLY. BOXES ON OPPOSITE SIDES OF FIRE RATED WALLS SHALL BE
OFFSET A MINIMUM OF 24" HORIZONTALLY. "THRU-THE-WALL" BOXES SHALL NOT BE
ALLOWED WITHOUT PRIOR WRITTEN APPROVAL OF THE ARCHITECT/ENGINEER.
4. VERIFY ALL FURNITURE, MODULAR FURNITURE, AND EQUIPMENT LOCATIONS WITH
ARCHITECTURAL PLANS, ELEVATIONS, AND REVIEWED SHOP DRAWINGS. PRIOR TO MAKING
THE ACTUAL TELECOMMUNICATIONS INSTALLATION, ADJUST OUTLETS OR CONNECTION
LOCATIONS TO ACCOMMODATE FURNITURE AND/OR EQUIPMENT.
5. TELECOMMUNICATIONS EQUIPMENT SHALL BE MOUNTED TO ALLOW ACCESS TO
ELECTRICAL AND MECHANICAL EQUIPMENT. ALL MOUNTING OF TELECOMMUNICATION
DEVICES ON EQUIPMENT SUPPLIED BY ANOTHER CONTRACTOR SHALL BE APPROVED IN
ADVANCE BY THE OTHER CONTRACTOR.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL
OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE
EXPENSE OF THIS CONTRACTOR. ALL CONDUITS THROUGH WALLS SHALL BE GROUTED OR
SEALED INTO OPENINGS.
7. ALL MATERIALS USED TO SEAL PENETRATIONS OF FIRE RATED WALLS AND FLOORS SHALL
BE TESTED AND CERTIFIED AS A SYSTEM PER ASTM E814 STANDARDS FOR FIRE TESTS OF
THROUGH-PENETRATION FIRESTOPS. REFER TO 27 05 03 AND 28 05 03 AND 26 05 03 FOR
ADDITIONAL INFORMATION AND REQUIREMENTS SPECIFIC TO FIRESTOPPING.
8. THE TECHNOLOGY CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND REPLACEMENT OF
THE CEILINGS, CEILING TILES, AND CEILING GRID ASSOCIATED WITH THE AREAS OF WORK
BY ALL CONTRACTORS.
9. ALL LADDER RACK AND CABLE TRAY SIZES ARE AS DEFINED ON THE DRAWINGS. REFER TO
SPECIFICATION SECTIONS 27 05 28 AND 27 11 00 FOR APPROVED MANUFACTURERS AND
INSTALLATION REQUIREMENTS.
10. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO THE
WALLS, FLOORS, CEILINGS, AND ROOFS. THE CONTRACTOR WHOSE WORK CAUSES
DAMAGE IS RESPONSIBLE FOR PATCHING TO MATCH ORIGINAL CONSTRUCTION, FIRE
RATING, AND FINISH.
11. FLUSH MOUNT ALL TELECOMMUNICATION OUTLETS AT +18" FROM FLOOR (CENTERLINE
DIMENSION), EXCEPT WHERE OTHERWISE NOTED. OUTLETS MAY BE SURFACE MOUNTED
WHEN CONDUIT IS SPECIFIED EXPOSED.
TECHNOLOGY INSTALLATION NOTES:
GENERAL NOTES:
1. ALL SYMBOLS AND ABBREVIATIONS LISTED MAY NOT BE APPLICABLE TO THIS PROJECT.
REFER TO THE TECHNOLOGY EQUIPMENT SCHEDULE FOR MORE COMPLETE DESCRIPTION
AND ITEMS.
2. ALL SYMBOLS AND ABBREVIATIONS REFER TO TECHNOLOGY SHEETS ONLY AS DEFINED ON
THE SHEET INDEX. REFER TO THE GENERAL TECHNOLOGY NOTES FOR ADDITIONAL
INFORMATION.
3. ALL SYMBOLS LISTED ABOVE ARE FOR REFERENCE ONLY. REFER TO PLANS AND LINE TYPE
KEY FOR NEW, EXISTING TO REMAIN AND TO BE REMOVED ITEMS FOR ADDITIONAL
INFORMATION.
4. REFER TO RISERS ON SHEET(S): TN400
CABLE TRAY, CHANNEL TRAY, BASKET
TRAY
LADDER RACK
WIDTH X HEIGHT
WIDTH X HEIGHT
DIAMETERø C CONDUIT
CONDUIT DOWN
CONDUIT UP OR UP/DOWN
CONDUIT SLEEVE
CONTINUATION
PLAN OR DETAIL NUMBER
PLAN OR DETAIL NAME
PLAN OR DETAIL SCALE
DETAIL REFERRED TO BY SECTION CUT
SHEET DETAIL IS LOCATED ON
NAME
VIEW NAME
1/8" = 1'-0"
M101
SIMSIM
INDICATES SIMILAR DETAIL REFERENCED
IN MULTIPLE LOCATIONS
LEVEL NAME
10'-0" HEIGHT ABOVE
PROJECT 0'-0"
1 INDICATES NOTE USED TO DESCRIBE
ADDITIONAL INFORMATION ABOUT
WORK REQUIRED, SPECIFIC TO THE
SHEET AND/OR DETAIL
N O R
HT
INDICATES DIRECTION OF TRUE NORTH
VIEW KEY
LINE TYPE AND TAG KEY:
NEW WORK BY THIS CONTRACTOR (WIDE LINE)
NEW
EXISTING TO BE REMOVED (SHORT DASHED PATTERN)
NEW UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN)
EXISTING TO REMAIN OR WORK BY OTHERS (NARROW LINE)
EXISTING
EXISTING TO BE REMOVED BY OTHERS (SHORT DASHED PATTERN)
EXISTING UNDERFLOOR OR UNDERGROUND (LONG DASHED PATTERN)
HALFTONING DOES NOT MODIFY SCOPE.
'TAG'-E TAGS WITH DASH 'E' INDICATES THE REFERENCED OBJECT IS EXISTING
TAG UNDERLINED TAG INDICATES OBJECT IS IN-SCOPE. IF NEW, ADDITIONAL
INFORMATION IS AVAILABLE IN A SCHEDULE, MATERIAL LIST, OR SYMBOL LIST
INDICATES AN EXISTING SYSTEM'S POINT OF CONNECTION/REMOVAL
T101
BUILDING CODE: IBC 20** EDITION
UBC 20**
FIRE CODE: IFC 20** EDITION -OR-
NFPA: 1 20** EDITION
PLUMBING CODE: IPC 20** EDITION
UPC 20**
MECHANICAL CODE: IMC 20** EDITION
UMC 20**
ELECTRICAL CODE: NFPA 70 (NEC) 20** EDITION
LIFE SAFETY CODE: NFPA 101 20** EDITION
ENERGY CONSERVATION CODE: IECC 20**
ASHRAE 90.1 20**
HEALTH DEPARTMENT CODE: CURRENT EDITION
LOCAL BUILDING CODE: CURRENT EDITION
APPLICABLE CODES
CONTRACTOR SHALL COMPLY WITH APPLICABLE CODES AND LOCAL AMENDMENTS.
TEMPERATURE CONTROLS CONTRACTORT.C.C.
SECURITY CONTRACTORS.C.
AUDIO/VISUAL CONTRACTORA.V.C.
NURSE CALL CONTRACTORN.C.C.
CIVIL CONTRACTORC.C.
ASBESTOS ABATEMENT CONTRACTOR
FIRE PROTECTION CONTRACTORF.P.C.
HEATING CONTRACTORH.C.
PLUMBING CONTRACTORP.C.
GENERAL CONTRACTORG.C.
MECHANICAL CONTRACTORM.C.
VENTILATION CONTRACTORV.C.
ELECTRICAL CONTRACTORE.C.
A.C.
CONTRACTOR ABBREVIATION KEY
ABBR: DESCRIPTION:
TECHNOLOGY CONTRACTORT.C.
CONSTRUCTION MANAGERC.M.
FOOD SERVICE CONTRACTORF.S.C.
M
A X
20" MAX.
M
A X
20"-25" MAX.
M
A X
M
IN
. 4
M
A X
M
A X
10" MAX. 10"-24" MAX.
ADA GUIDELINES - FRONT ACCESS
ADA STANDARDS FOR ACCESSIBLE DESIGN
INSTALL ABOVE COUNTER
DEVICE AT 44" ABOVE
FINISHED FLOOR.
INSTALL ABOVE COUNTER
DEVICE AT 40" ABOVE
FINISHED FLOOR.
INSTALL DEVICE AT 18"
ABOVE FINISHED FLOOR.
ADA GUIDELINES - SIDE ACCESS
INSTALL DEVICE AT 44"
ABOVE FINISHED FLOOR.
INSTALL DEVICE AT 42"
ABOVE FINISHED FLOOR.
TECHNOLOGY SHEET INDEX
000-TN000 TECHNOLOGY COVERSHEET
000-TN400 TECHNOLOGY RISER DIAGRAMS
000-TN500 TECHNOLOGY DETAILS
000-TS100 CAMPUS TECHNOLOGY SITE PLAN
001-TN100 BASEMENT PLAN - TECHNOLOGY
001-TN101 LEVEL 01 PLAN - TECHNOLOGY
001-TN102 LEVEL 02 PLAN - TECHNOLOGY
003-TN100 BASEMENT PLAN - TECHNOLOGY
003-TN101 LEVEL 01 PLAN - TECHNOLOGY
007-TN100 BASEMENT PLAN - TECHNOLOGY
007-TN101 LEVEL 01 PLAN - TECHNOLOGY
009-TN100 BASEMENT PLAN - TECHNOLOGY
009-TN101 LEVEL 01 PLAN - TECHNOLOGY
009-TN102 LEVEL 02 PLAN - TECHNOLOGY
018-TD101 LEVEL 01 DEMOLITION PLAN - TECHNOLOGY
018-TN100 BASEMENT PLAN - TECHNOLOGY
018-TN101 LEVEL 01 PLAN - TECHNOLOGY
018-TN102 LEVEL 02 PLAN - TECHNOLOGY
018-TN200 DATA CENTER #122 PATHWAY LAYOUT - TECHNOLOGY
018-TN201 DATA CENTER #122 PHASE 1 PLAN - TECHNOLOGY
018-TN202 DATA CENTER #122 PHASE 2 PLAN - TECHNOLOGY
018-TN203 DATA CENTER #122 PHASE 3 PLAN - TECHNOLOGY
018-TN204 DATA CENTER #122 PHASE 4 PLAN - TECHNOLOGY
018-TN205 COPPER BACKBONE EQUIPMENT DETAIL
018-TN206 DATA CENTER STRUCTURED CABLING SYSTEM DIAGRAM
018-TN207 FIBER BACKBONE RISER-CORE A.
018-TN208 FIBER BACKBONE RISER-CORE B.
020-TN101 LEVEL 01 PLAN - TECHNOLOGY
020-TN102 LEVEL 02 PLAN - TECHNOLOGY
020-TN103 LEVEL 03 PLAN - TECHNOLOGY
021-TN101 LEVEL 01 PLAN - TECHNOLOGY
021-TN102 LEVEL 02 PLAN - TECHNOLOGY
023-TN100 BASEMENT PLAN - TECHNOLOGY
023-TN101 LEVEL 01 PLAN - TECHNOLOGY
024-TN100 BASEMENT PLAN - TECHNOLOGY
024-TN101 LEVEL 01 PLAN - TECHNOLOGY
024-TN102 LEVEL 02 PLAN - TECHNOLOGY
024-TN103 LEVEL 03 PLAN - TECHNOLOGY
025-TN100 BASEMENT PLAN - TECHNOLOGY
025-TN101 LEVEL 01 PLAN - TECHNOLOGY
026-TN100 BASEMENT PLAN - TECHNOLOGY
026-TN101 LEVEL 01 PLAN - TECHNOLOGY
026-TN102 LEVEL 02 PLAN - TECHNOLOGY
026-TN103 LEVEL 03 PLAN - TECHNOLOGY
027-TN100 BASEMENT PLAN - TECHNOLOGY
027-TN101 LEVEL 01 PLAN - TECHNOLOGY
027-TN102 LEVEL 02 PLAN - TECHNOLOGY
027-TN103 LEVEL 03 PLAN - TECHNOLOGY
028-TN100 BASEMENT PLAN - TECHNOLOGY
028-TN101 LEVEL 01 PLAN - TECHNOLOGY
028-TN102 LEVEL 02 PLAN - TECHNOLOGY
030-TN100 BASEMENT PLAN - TECHNOLOGY
030-TN101 LEVEL 01 PLAN - TECHNOLOGY
030-TN102 LEVEL 02 PLAN - TECHNOLOGY
030-TN103 LEVEL 03 PLAN - TECHNOLOGY
031-TN100 OVERALL BASEMENT FLOOR PLAN - TECHNOLOGY
031-TN101 OVERALL GROUND FLOOR PLAN - TECHNOLOGY
031-TN102 OVERALL FIRST FLOOR PLAN - TECHNOLOGY
031-TN103 OVERALL SECOND FLOOR PLAN - TECHNOLOGY
031-TN104 OVERALL THIRD FLOOR PLAN - TECHNOLOGY
035-TN0SB SUB BASEMENT PLAN - TECHNOLOGY
035-TN100 BASEMENT PLAN - TECHNOLOGY
035-TN101 LEVEL 01 PLAN - TECHNOLOGY
035-TN102 LEVEL 02 PLAN - TECHNOLOGY
035-TN103 LEVEL 03 PLAN - TECHNOLOGY
036-TN100 BASEMENT AND FIRST FLOOR PLAN - TECHNOLOGY
060-TN100 LEVEL 01 PLAN - TECHNOLOGY
210-TN100 BASEMENT PLAN - TECHNOLOGY
210-TN101 LEVEL 01 PLAN - TECHNOLOGY
210-TN102 LEVEL 02 PLAN - TECHNOLOGY
210-TN103 LEVEL 03 PLAN - TECHNOLOGY
211-TN100 BASEMENT PLAN - TECHNOLOGY
211-TN101 LEVEL 01 PLAN - TECHNOLOGY
211-TN102 LEVEL 02 PLAN - TECHNOLOGY
211-TN103 LEVEL 03 PLAN - TECHNOLOGY
212-TN100 BASEMENT PLAN - TECHNOLOGY
212-TN101 LEVEL 01 PLAN - TECHNOLOGY
212-TN102 LEVEL 02 PLAN - TECHNOLOGY
247-TN100 BASEMENT PLAN - TECHNOLOGY
247-TN110 LEVEL 01 PLAN - TECHNOLOGY
252-TN101 LEVEL 01 PLAN - TECHNOLOGY
259-TN101 LEVEL 01 PLAN - TECHNOLOGY
259-TN102 LEVEL 02 PLAN - TECHNOLOGY
261-TN101 LEVEL 01 PLAN - TECHNOLOGY
GRAND TOTAL: 84
SUGGESTED MATRIX OF RESPONSIBILITY
ITEM: SHOWN ON:
FURNISHED
BY:
INSTALLED
BY: NOTES:
TECHNOLOGY ROUGH-IN, REFER TO
TECHNOLOGY EQUIPMENT SCHEDULE
AND SPECIFICATIONS FOR DEFINITION
T-SERIES E.C. E.C. 3. 4.
INFORMATION OUTLET FACEPLATES,
JACKS, AND TERMINATIONS
T-SERIES T.C. T.C.
CONDUIT SLEEVES (WHEN SHOWN ON
DRAWINGS)
T-SERIES E.C. E.C.
CONDUIT SLEEVES (NOT SHOWN BUT
REQUIRED FOR PROPER INSTALLATION
OF SYSTEM)
N/A T.C. T.C. 2. 4.
TELECOMMUNICATION SYSTEMS
ROUGH-IN
T-SERIES E.C. [T.C] E.C. 1.
TELECOMMUNICATION EQUIPMENT,
CABLING, AND TERMINATIONS
T-SERIES T.C. T.C.
CABLE TRAY (INCLUDING WIRE BASKET
TRAY) REFER TO SPECIFICATION
SECTION 27 05 28 FOR DEFINITION
T-SERIES E.C. E.C.
LADDER RACK T-SERIES T.C. T.C. 5.
GROUNDING LUGS ON TECHNOLOGY
EQUIPMENT
T-SERIES T.C. E.C. 6.
BONDING SYSTEM FOR TECHNOLOGY
SYSTEM, REFER TO SPECIFICATION
SECTION 27 05 26 FOR DEFINITION
T-SERIES E.C. E.C. 7. 8.
CONNECTION OF TECHNOLOGY
BONDING SYSTEM TO THE ELECTRICAL
GROUND SYSTEM
T-SERIES E.C. E.C.
LINE VOLTAGE POWER (+120V OR
GREATER)
E-SERIES E.C. E.C.
LINE VOLTAGE POWER (NOT SHOWN
BUT REQUIRED FOR PROPER
INSTALLATION OF SYSTEM)
N/A T.C. E.C. 2. 4.
LINE VOLTAGE POWER FOR DOOR
HARDWARE POWER SUPPLIES
ARCH SPEC E.C. E.C.
LOW VOLTAGE CABLING FOR
TECHNOLOGY SYSTEMS
T-SERIES T.C. T.C.
CABLE HANGERS AND SUPPORTS OR
OTHER CABLE ROUTING METHODS
(OTHER THAN CONDUIT AND CABLE
TRAY)
T-SERIES T.C. T.C. 5.
TECHNOLOGY SERVICE ENTRANCE
CONDUITS, HANDHOLES, AND
MANHOLES
[E]T-SERIES E.C. E.C.
FLOOR BOX (ROUGH-IN) T & E SERIES E.C. E.C.
SUGGESTED MATRIX OF RESPONSIBILITY NOTES
1. LOCATIONS OF TELECOMMUNICATIONS ROUGH-INS SHALL BE INDICATED BY THE INFORMATION
OUTLET SYMBOLS ON THE DRAWINGS. REFER TO THE TECHNOLOGY SYMBOL LIST FOR
ADDITIONAL INFORMATION.
2. BASED ON THE INHERENT DIFFERENCES IN PRODUCTS FROM VARIOUS MANUFACTURERS, ALL
REQUIRED EQUIPMENT MAY NOT BE SHOWN ON THE DRAWINGS FOR ALL ACCEPTABLE
MANUFACTURERS.
3. INCLUDES BACKBOXES AND CONDUIT REQUIRED FOR THE TECHNOLOGY SYSTEMS
INSTALLATION. THE E.C. SHALL BASE THE BID ON THE BASIS OF DESIGN SHOWN ON THE
CONTRACT DOCUMENTS.
4. ALL CHANGES TO THE SLEEVES, BACKBOXES, CONDUITS, AND POWER REQUIRED BECAUSE OF
THE T.C.'S SELECTION OF AN ALTERNATE ACCEPTABLE MANUFACTURER OR FROM SYSTEM
CONFIGURATIONS THAT ARE LEFT TO THE CHOICE OF THE CONTRACTOR SHALL BE INCLUDED
IN THE T.C.'S BID. THIS BID SHALL INCLUDE INSTALLATION BY A LICENSED ELECTRICIAN.
5. UNLESS TRADE RULES DICTATE OTHERWISE.
6. FURNISHED AS PART OF THE EQUIPMENT WHEN POSSIBLE, OR FURNISHED TO THE E.C. FOR
INSTALLATION IN THE FIELD.
7. INCLUDES ALL CONDUCTORS, GROUND BARS, AND TERMINATIONS FOR THE COMPLETE
BONDING SYSTEM REQUIRED BY THE SPECIFICATIONS.
8. REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF PANELS AND SWITCHBOARDS SHOWN
IN THE TECHNOLOGY BONDING RISER DIAGRAM AND TYPICAL TELECOM ROOM BONDING FLOW
DIAGRAM.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/T
.0
V A
-C h ill ic o th e
C a m p u s
C .r v t
/6
/2
:3
:2
P M
000-TN000
TECHNOLOGY COVERSHEET
07/07/2023 ACA ECW
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
BID DOCUMENTS
CAMPUS
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
THE EQUIPMENT LIST ABBREVIATIONS AND THE GENERAL TECHNOLOGY EQUIPMENT SCHEDULE ARE FOR THE CONVENIENCE OF THE CONTRACTOR. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF QUANTITIES AND SHALL FURNISH ALL MATERIAL REQUIRED, WHETHER SPECIFIED OR NOT, TO PRODUCE A SATISFACTORY WORKING SYSTEM.
CATALOG NUMBERS ARE NOT TO BE CONSIDERED COMPLETE BUT ARE GIVEN ONLY TO AID THE CONTRACTOR IN THE SEARCH FOR MATERIAL. NO MATERIAL SHALL BE ORDERED BY MANUFACTURER AND CATALOG NUMBER ONLY. EACH CONTRACTOR SHALL FIRST READ THE COMPLETE DESCRIPTION OF THE MATERIAL ON THESE DRAWINGS AND SPECIFICATIONS. THE FIRST MANUFACTURER LISTED IS THE BASIS OF DESIGN. "STANDARD COLOR" INDICATES FACTORY FINISH AVAILABLE AT NO ADDITIONAL CHARGE.
TECHNOLOGY EQUIPMENT SCHEDULE
EQUIPMENT LIST
ABBREVIATION EQUIPMENT LIST DESCRIPTION
MANUFACTURER AND
MODEL
SC-BP-1 ANGLED BLANKING PANEL INSERTS, 1RMU OR 2RMU, PROVIDE CLEAN ASETHETIC TRASITION FROM ANGLED PATCH PANELS
TO FLAT EQUIPMENT, IMPROVES AIRFLOW AND THERMAL MANAGEMENT.
LEVITON
#49254-BA SERIES
SC-CT-1 18" W x 4"DEEP WIRE-MESH STYLE CABLE TRAY, HIGH QUALITY WELDED STEEL CONSTRUCTION, ELECTRO-GALVINIZED
FINISH WITH MOUNTING HARDWARE, SPLICE KIT AND GROUNDING JUMPERS
CABLOFIL
CF105/450EZ
OR APPROVED EQUAL
SC-FPW-1 4" FIRE-RATED PATHWAY FLOOR GRID SYSTEM, 14"L x 23"W x 4-1/2"H, STEEL CONSTRUCTION, (4) 4" PATHWAYS, FLOOR FRAME
KIT,
UL CERTIFIED FIRE BARRIER PATHWAY, 4HR FIRE RATING
STI
EZDG444S2
OR APPROVED EQUAL
SC-FPW-2 4" FIRE-RATED PATHWAY FLOOR GRID SYSTEM, 14"L x 23"W x 4-1/2"H, STEEL CONSTRUCTION, (8) 4" PATHWAYS, FLOOR FRAME
KIT,
UL CERTIFIED FIRE BARRIER PATHWAY, 4HR FIRE RATING
STI
EZDG844S2
OR APPROVED EQUAL
SC-FT-1 DIRECTIONAL AIRFLOW PERFORATED FLOOR TILE PANELS, 2' x 2', STEEL CONSTRUCTION, 32% OPEN AIR DELIVER, 93% TOTAL AIR CAPTURE (TAC), COOLS UP TO 8KW PER CABINET, 1250 LB STATIC LOAD CAPACITY, WITH ADJUSTABLE SCREW TO DIRECT
AIRFLOW AND SLIDE DAMPER.
TATE INC.
#DIRECTIONAL PERFORATED
PANEL-32
#NF8N-113N-E40-1
#39043-E63
OR APPROVED EQUAL
SC-LR-1 LADDER RUNWAY, 18"W TUBULAR STEEL CONSTRUCTION, RUST-RESISTANT BLACK ENAMEL FINISH WITH MOUNTING HARDWARE, ADAPTERS, FITTINGS, SUPPORTS WITH CROSS-MEMBER RADIUS DROPS AS REQUIRED, UL LISTED
CHATSWORTH
#11252-718
OR APPROVED ERQUAL
SC-MDA-1
SC-HDA-1
NETWORK CABINET - 83.4"H x 40"W x 43.3"D, 45RMU, SINGLE PERFORATED METAL FRONT DOOR WITH KEYED SWING HANDLE LOCK, DOUBLE PERFORATED METAL REAR DOOR WITH KEYED SWING HANDLE LATCH, STANDARD TOP PANEL WITH 2-PIECE BRUSH, SIDE PANELS WITH BRUSH SEALED CABLE OPENINGS, BOTTOM PANEL WITH BRUSH, INTEGRATED GROUNDING TABS.
PROVIDE ANGLED BLANKING PANELS INSERTS AT EMPTY SPACE BETWEEN EQIPMENT.
CHATSWORTH
#NF8N-113N-E40-1
#39043-E63
OR APPROVED EQUAL
SC-MPP-1 ANGLED, QUICKPORT, 110 STYLE, MODULAR PATCH PANEL, 24-PORT CATEGORY 6 MODULAR RJ45 SNAP IN JACKS,WELEDED STEEL CONSTRUCTION, BLOCK POWDER COAT FINISH, MOUNT DIRECTLY TO EIA STANDARD 19" WIDE RACK MOUNTING
SYSTEM. REQUIRES 1 RMU OF SPACE.
LEVITON
#69587-U24
SC-MPP-2 ANGLED, QUICKPORT, 110 STYLE, HIGH DENSITY, MODULAR PATCH PANEL, 48-PORT CATEGORY 6 MODULAR RJ45 SNAP IN JACKS,WELEDED STEEL CONSTRUCTION, BLOCK POWDER COAT FINISH, MOUNT DIRECTLY TO EIA STANDARD 19" WIDE RACK MOUNTING SYSTEM. REQUIRES 1 RMU OF SPACE, WITH HIGH DENSITY 6-PORT COPPER CASSETTES.
LEVITON
#E2X1A-S48
#E2XHD-BRK
SC-MPP-3 VOICE GRADE, HIGH DENSITY, MODULAR PATCH PANEL, 48-PORT, WELDED STEEL CONSTRUCTION, MOUNT DIRECTLY TO EIA STANDARD 19"W RACK MOUNTING SYSTEM, WITH 25-PAIR FEMALE RJ-21X CONNECTOR WITH STANDOFF BOLT, CONNECT (4)
CONDUCTORS PER PORT
LEVITON
#49018-J48
SC-RK-1 20"W x 7'-0" x 15"DEEP, HEAVY-DUTY, UNIVERSAL EQUIPMENT RACK, ALUMINUM EXRUSION CONSTRUCTION, BOLTED ASSEMBLY, 10-32 AND12-24 PRE-DRILLED HOLES, GLACIER WHITE FINISH WITH VERTICAL RACK BONDING BUSBAR
CHATSWORTH
#46753-E03 #40160-072
SC-SPR-1 MODULAR DATA LINE SURGE PROTECTION SYSTEM WITH "PRM24" CHASSIS, MOUNTING HARDWARE, GROUND WIRE AND (24) DATA LINE MODULES ("PTEL2R" FOR ANALOG TELEPHONE PROTECTION), MOUNT DIRECTLY TO EIA STANDARD 19" WIDE RACK MOUNTING SYSTEM. EACH "PTEL2R" PROTECTS UP TO TWO LINES, USE PINS #3&4 AND #5&6 ON RJ45 CONNECTORS FOR
TERMINATIONS.
APC
#PRM24-PTEL2R
SC-SVR-1 SERVER CABINET - 84.6" x 23.6"W x 43.30"D, 45RMU, SINGLE PERFORATED METAL FRONT DOOR WITH KEYED SWING HANDLE LOCK, DOUBLE PERFORATED METAL REAR DOOR WITH KEYED SWING HANDLE LATCH, TOP PANEL WITH 2-PIECE BRUSH, (2) SOLID SIDE PANELS, BOTTOM PANEL WITH BRUSH, AIR DAM, FINGER CABLE MANAGER, CASTER KIT, PDU BRACKETS, GLACIER WHITE FINISH, UL LISTED. PROVIDE ANGLED BLANKING PANELS AT EMPTY SPACE BETWEEN EQUIPMENT.
CHATSWORTH
#FF1N-113C-E42-F
OR APPROVED EQUAL
No. Revisions: Date:
BID DOCUMENTS 07/07/2023
Eddie C. Willis, Jr.
REG. NO. 191562R
EXPIRES 12-31-25
REGIS
TE
R
ED
C
O
MMUNICA T IONS DISTRIBUT IO
N
DESIG
NER
RCDD
22003180.00
BLDG #18
SERVER RM #122
CORE “A”
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OM4 MM / 12 OS1 SM
24 OS2 SM24 OM4 MM / 12 OS1 SM
24OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM
BLDG. #3 MDF #103
24 OS2 SM
BLDG. #1 MDF #BB105
24 OS2 SMBLDG. #1 TR #139
24 OS2 SM
BLDG. #9 MDF #109
24 OS2 SM
BLDG. #20 TE #204
24 OS2 SM BLDG. #21 MDF #28A
24 OS2 SM
BLDG. #23 MDF #121A
24 OS2 SM BLDG. #24 MDF GB103
24 OS2 SM
BLDG. #24 TR #123
24 OS2 SM BLDG. #24 TR #222
24 OS2 SM
BLDG. #25 MDF #102A
24 OS2 SM BLDG. #27 MDF #14
24 OS2 SM
BLDG. #27 TR #167
24 OS2 SM BLDG. #27 TR #271
24 OS2 SM
BLDG. #30 MDF #8E
24 OS2 SM BLDG. #30 TR #127
24 OS2 SM
BLDG. #30 TR #226
24 OS2 SM BLDG. #35 MDF #BC102
24 OS2 SM
BLDG. #35 TR #1A109
24 OS2 SM BLDG. #35 TR #2A109
24 OS2 SM
BLDG. #35 TR #3A109
24 OS2 SM BLDG. #36 TE #36C
24 OS2 SM
BLDG. #60 TE #20
24 OS2 SM
BLDG. #1 TR #179
24 OS2 SMBLDG. #1 TR #242
24 OS2 SM
BLDG. #1 TR #284
24 OS2 SMBLDG. #7 MDF #108D
24 OS2 SM
BLDG. #18 TR #115
24 OM4 AND 12 OS1BLDG. #18 TR #225A
24 OM4 AND 12 OS1
BLDG. #26 TR #133
24 OS2 SM
BLDG. #28 MDF #201
24 OS2 SM
BLDG. #31 TR #G-182
24 OS2 SM
BLDG. #31 TR #G-500D
24 OS2 SM
BLDG. #31 TR #1-210
24 OS2 SM
BLDG. #210 MDF #G023
24 OS2 SM
BLDG. #210 TR #202A
24 OS2 SM
BLDG. #26 MDF #27
24 OS2 SM
BLDG. #26 TR #200A
24 OS2 SM
BLDG. #31 MDF #G-202
24 OS2 SM
BLDG. #31 TR #G-345G
24 OS2 SM
BLDG. #31 TR #F-204
24 OS2 SM
BLDG. #31 TR #2-207A
24 OS2 SM
BLDG. #210 TR #102A
24 OS2 SM
24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
BLDG. #212 MDF #15A
24 OS2 SMBLDG. #212 TR #102
24 OS2 SM
BLDG. #247 TE #109
24 OS2 SM
BLDG. #259 MDF #2-9
24 OS2 SM
BLDG. #212 TR #225
24 OS2 SM
BLDG. #211 TR #G007
24 OS2 SM
BLDG. #211 TR #189A
24 OS2 SM
BLDG. #211 TR #289A
24 OS2 SM
BLDG. #211 MDF #G020
24 OS2 SM
BLDG. #211 TR #108A
24 OS2 SM
BLDG. #211 TR #208A
24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM
BLDG. #252 TE #103
24 OS2 SM
24 OS2 SM
BLDG. #261 MDF #103
24 OS2 SM
BLDG #18
SERVER RM #122
CORE “B”
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OM4 MM / 12 OS1 SM
24 OS2 SM24 OM4 MM / 12 OS1 SM
24OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM
BLDG. #3 MDF #103
24 OS2 SM
BLDG. #1 MDF #BB105
24 OS2 SMBLDG. #1 TR #139
24 OS2 SM
BLDG. #9 MDF #109
24 OS2 SM
BLDG. #20 TE #204
24 OS2 SM BLDG. #21 MDF #28A
24 OS2 SM
BLDG. #23 MDF #121A
24 OS2 SM BLDG. #24 MDF GB103
24 OS2 SM
BLDG. #24 TR #123
24 OS2 SM BLDG. #24 TR #222
24 OS2 SM
BLDG. #25 MDF #102A
24 OS2 SM BLDG. #27 MDF #14
24 OS2 SM
BLDG. #27 TR #167
24 OS2 SM BLDG. #27 TR #271
24 OS2 SM
BLDG. #30 MDF #8E
24 OS2 SM BLDG. #30 TR #127
24 OS2 SM
BLDG. #30 TR #226
24 OS2 SM BLDG. #35 MDF #BC102
24 OS2 SM
BLDG. #35 TR #1A109
24 OS2 SM BLDG. #35 TR #2A109
24 OS2 SM
BLDG. #35 TR #3A109
24 OS2 SM BLDG. #36 TE #36C
24 OS2 SM
BLDG. #60 TE #20
24 OS2 SM
BLDG. #1 TR #179
24 OS2 SMBLDG. #1 TR #242
24 OS2 SM
BLDG. #1 TR #284
24 OS2 SMBLDG. #7 MDF #108D
24 OS2 SM
BLDG. #18 TR #115
24 OM4 AND 12 OS1BLDG. #18 TR #225A
24 OM4 AND 12 OS1
BLDG. #26 TR #133
24 OS2 SM
BLDG. #28 MDF #201
24 OS2 SM
BLDG. #31 TR #G-182
24 OS2 SM
BLDG. #31 TR #G-500D
24 OS2 SM
BLDG. #31 TR #1-210
24 OS2 SM
BLDG. #210 MDF #G023
24 OS2 SM
BLDG. #210 TR #202A
24 OS2 SM
BLDG. #26 MDF #27
24 OS2 SM
BLDG. #26 TR #200A
24 OS2 SM
BLDG. #31 MDF #G-202
24 OS2 SM
BLDG. #31 TR #G-345G
24 OS2 SM
BLDG. #31 TR #F-204
24 OS2 SM
BLDG. #31 TR #2-207A
24 OS2 SM
BLDG. #210 TR #102A
24 OS2 SM
24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM24 OS2 SM
BLDG. #212 MDF #15A
24 OS2 SMBLDG. #212 TR #102
24 OS2 SM
BLDG. #247 TE #109
24 OS2 SM
BLDG. #259 MDF #2-9
24 OS2 SM
BLDG. #212 TR #225
24 OS2 SM
BLDG. #211 TR #G007
24 OS2 SM
BLDG. #211 TR #189A
24 OS2 SM
BLDG. #211 TR #289A
24 OS2 SM
BLDG. #211 MDF #G020
24 OS2 SM
BLDG. #211 TR #108A
24 OS2 SM
BLDG. #211 TR #208A
24 OS2 SM
24 OS2 SM24 OS2 SM
24 OS2 SM
BLDG. #252 TE #103
24 OS2 SM
24 OS2 SM
BLDG. #261 MDF #103
24 OS2 SM
BLDG #18
(T.E.R.) #012A
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER
BLDG. #3 MDF #103
25 PAIR COPPER
BLDG. #1 MDF #BB105
25 PAIR COPPERBLDG. #1 TR #139
25 PAIR COPPER
BLDG. #9 MDF #109
25 PAIR COPPER
BLDG. #20 TE #204
25 PAIR COPPER BLDG. #21 MDF #28A
25 PAIR COPPER
BLDG. #23 MDF #121A
25 PAIR COPPER BLDG. #24 MDF GB103
25 PAIR COPPER
BLDG. #24 TR #123
25 PAIR COPPER BLDG. #24 TR #222
25 PAIR COPPER
BLDG. #25 MDF #102A
25 PAIR COPPER BLDG. #27 MDF #14
25 PAIR COPPER
BLDG. #27 TR #167
25 PAIR COPPER BLDG. #27 TR #271
25 PAIR COPPER
BLDG. #30 MDF #8E
25 PAIR COPPER BLDG. #30 TR #127
25 PAIR COPPER
BLDG. #30 TR #226
25 PAIR COPPER BLDG. #35 MDF #BC102
25 PAIR COPPER
BLDG. #35 TR #1A109
25 PAIR COPPER BLDG. #35 TR #2A109
25 PAIR COPPER
BLDG. #35 TR #3A109
25 PAIR COPPER BLDG. #36 TE #36C
25 PAIR COPPER
BLDG. #60 TE #20
25 PAIR COPPER
BLDG. #1 TR #179
25 PAIR COPPERBLDG. #1 TR #242
25 PAIR COPPER
BLDG. #1 TR #284
25 PAIR COPPERBLDG. #7 MDF #108D
25 PAIR COPPER
BLDG. #18 TR #115
25 PAIR COPPERBLDG. #18 TR #225A
25 PAIR COPPER
BLDG. #26 TR #133
25 PAIR COPPER
BLDG. #28 MDF #201
25 PAIR COPPER
BLDG. #31 TR #G-182
25 PAIR COPPER
BLDG. #31 TR #G-500D
25 PAIR COPPER
BLDG. #31 TR #1-210
25 PAIR COPPER
BLDG. #210 MDF #G023
25 PAIR COPPER
BLDG. #210 TR #202A
25 PAIR COPPER
BLDG. #26 MDF #27
25 PAIR COPPER
BLDG. #26 TR #200A
25 PAIR COPPER
BLDG. #31 MDF #G-202
25 PAIR COPPER
BLDG. #31 TR #G-345G
25 PAIR COPPER
BLDG. #31 TR #F-204
25 PAIR COPPER
BLDG. #31 TR #2-207A
25 PAIR COPPER
BLDG. #210 TR #102A
25 PAIR COPPER
25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
BLDG. #212 MDF #15A
25 PAIR COPPERBLDG. #212 TR #102
25 PAIR COPPER
BLDG. #247 TE #109
25 PAIR COPPER
BLDG. #259 MDF #2-9
25 PAIR COPPER
BLDG. #212 TR #225
25 PAIR COPPER
BLDG. #211 TR #G007
25 PAIR COPPER
BLDG. #211 TR #189A
25 PAIR COPPER
BLDG. #211 TR #289A
25 PAIR COPPER
BLDG. #211 MDF #G020
25 PAIR COPPER
BLDG. #211 TR #108A
25 PAIR COPPER
BLDG. #211 TR #208A
25 PAIR COPPER
25 PAIR COPPER25 PAIR COPPER
25 PAIR COPPER
BLDG. #252 TE #103
25 PAIR COPPER
25 PAIR COPPER
BLDG. #261 MDF #103
25 PAIR COPPER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/T
.0
V A
-C h ill ic o th e
C a m p u s
C .r v t
/6
/2
:3
:2
P M
000-TN400
TECHNOLOGY RISER DIAGRAMS
07/07/2023 ACA ECW
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
BID DOCUMENTS
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
NO SCALE
VA CHILLICOTHE - FIBER BACKBONE RISER - CORE A
1 NO SCALE
VA CHILLICOTHE - FIBER BACKBONE RISER - CORE B
NO SCALE
VA CHILLICOTHE - COPPER BACKBONE RISER
No. Revisions: Date:
BID DOCUMENTS 07/07/2023
Eddie C. Willis, Jr.
REG. NO. 191562R
EXPIRES 12-31-25
REGIS
TE
R
ED
C
O
MMUNICA T IONS DISTRIBUT IO
N
DESIG
NER
LID SHALL BE MARKED
"TELECOMMUNICATIONS"
MOUSE HOLES - (4).
CONDUIT ENTRY PENETRATION NOT TO
EXCEED 25 PERCENT OF SIDE WALL AREA
STAINLESS STEEL HEX
HEAD BOLT W/WASHER
PULL SLOT
SKID RESISTANT SURFACE
EXTENSIONS AS
REQUIRED BY
CONDUIT DEPTH
KNOCKOUTS - (8)
SLOPE GRADE AWAY
FROM COVER 1" IN 3'
GRAVEL DRAINAGE BED MINIMUM 6"
DEPTH. MINIMUM SIZE GRAVEL 1"
NOTES:
1. ALL DIMENSIONS ARE NOMINAL INSIDE CLEARANCES.
2. ANY SPLICES OR DEVICES IN HANDHOLE SHALL BE SUBMERGIBLE.
8" E
XTENSIO
N
LOG
O
LENGTH
W
IDTH
DEPTH
BELOW GRADE CONCRETE WALL OR FLOOR
HYDROSTATIC SEAL ASSEMBLY. INSTALL
ASSEMBLY SO BOLT HEADS ARE ACCESSIBLE
FROM INTERIOR FOR DISASSEMBLY.
"LINK-SEAL", OZ-GEDNEY "CSM" SERIES,
CROUSE-HINDS "TW" SERIES, REFER TO NOTE #1
DUCT SEALING COMPOUND IN INTERIOR OF CONDUIT.
JM CLIPPER DUXSEAL OR EQUIVALENT PULL BOX, CONDUIT
FITTING OR AUXILIARY
GUTTER, REFER TO
NOTE #2
APPLY CAULK FLUSH WITH SURFACE AND PROVIDE
CHROME ESCUTCHEON RING FOR FINISHED WALLS
CAST OR MALLEABLE IRON SLEEVE WITH WATER
STOP, IF NOT CORE DRILLED
IF APPLICABLE, DOWEL DUCT BANK TO CONCRETE
WALL WITH MINIMUM OF (4) #4 EMBEDDED
MINIMUM OF 4" AND EPOXY ANCHORED
NOTES:
1. HYDROSTATIC SEAL SELECTION BASED ON OUTSIDE DIAMETER OF CONDUIT AND INSIDE
DIAMETER OF SLEEVE OR BORE.
2. PROVIDE PULL BOX, CONDUIT FITTING OR AUXILIARY GUTTER, SIZED PER N.E.C. WITHIN 5' OF
CONDUIT ENTER TO ALLOW SEALING OF CONDUITS. BOX ORIENTATION IS DIAGRAMMATIC
SEALING COMPOUND SHALL BE NON-HARDENING MATERIAL FOR WATERSTOP AND MOISTURE
BARRIER, OZ/GEDNEY "DUX" OR APPROVED EQUIVALENT SEAL BOTH ENDS OF EXTERIOR
CONDUITS.
3. THIS DETAIL APPLIES TO ALL BELOW GRADE WALL AND FLOOR CONDUIT ENTRIES INTO
BUILDING.
RIGID METAL CONDUIT THRU WALL
MARKER TAPE WITH
METALLIC TRACER, 12"
ABOVE DUCT BANK
(4) #4 BARS CONTINUOUS
ON TOP AND BOTTOM
4" (5") SCHEDULE 40 PVC
4" MINIMUM COMPACTED
AGGREGATE BASE.
[PRECAST CONCRETE PADS
ON UNDISTURBED EARTH
UNDER EACH SPACER]
#4 TIE BARS AT 3'-0" ON CENTER
INTERMEDIATE SPACER
CONDUIT NONMETALLIC SPACER,
MAXIMUM 5' ON CENTER. [CARLON
S288 SERIES, UNDERGROUND
DEVICES WUNPEECE, OSBORN
ASSOCIATES 5100 SERIES]
3" MIN.
M
IN
M
IN
M A
X
/2
/4
2500 PSI CONCRETE
7 1/2" 7 1/2" 7 1/2" 7 1/2"
CLEAN EARTH
BACKFILL PLACED PER
SPECIFICATIONS
FINISHED GRADE
NOTES:
1. INSTALL 2000LB TENSILE STRENGTH BRAIDED POLYPROPYLENE
PULLCORD IN ALL CONDUITS.
2. TRENCHING AND BACKFILL ACCORDING TO SPECIFICATIONS.
3. MINIMUM OF 4'-0" CLEAR BETWEEN ADJACENT DUCTBANKS.
4. DOWEL ENDS OF DUCTBANK TO FOUNDATION OR MANHOLE WITH A
MINIMUM OF (4) #4 DOWELS.
(3) FIBER INNERDUCTS &
CAT5E COPPER CABLES
IN EACH CONDUIT
(3) FIBER INNERDUCTS &
OS2 OPTICAL FIBER
CABLES IN EACH CONDUIT
(3) FIBER INNERDUCTS &
CAT5E COPPER CABLES
IN EACH CONDUIT
/2
MARKER TAPE WITH
METALLIC TRACER, 12"
ABOVE DUCT BANK
(4) #4 BARS CONTINUOUS
ON TOP AND BOTTOM
4" (5") SCHEDULE 40 PVC
4" MINIMUM COMPACTED
AGGREGATE BASE.
[PRECAST CONCRETE PADS
ON UNDISTURBED EARTH
UNDER EACH SPACER]
#4 TIE BARS AT 3'-0" ON CENTER
INTERMEDIATE SPACER
CONDUIT NONMETALLIC SPACER,
MAXIMUM 5' ON CENTER. [CARLON
S288 SERIES, UNDERGROUND
DEVICES WUNPEECE, OSBORN
ASSOCIATES 5100 SERIES]
M
IN
. 2
M
IN
M A
X
/2
/4
2500 PSI CONCRETE
CLEAN EARTH
BACKFILL PLACED PER
SPECIFICATIONS
FINISHED GRADE
NOTES:
1. INSTALL 2000LB TENSILE STRENGTH BRAIDED POLYPROPYLENE
PULLCORD IN ALL CONDUITS.
2. TRENCHING AND BACKFILL ACCORDING TO SPECIFICATIONS.
3. MINIMUM OF 4'-0" CLEAR BETWEEN ADJACENT DUCTBANKS.
4. DOWEL ENDS OF DUCTBANK TO FOUNDATION OR MANHOLE WITH A
MINIMUM OF (4) #4 DOWELS.
(3) FIBER INNERDUCTS &
OS2 OPTICAL FIBER
CABLES IN EACH CONDUIT
(2) 4" SPARE CONDUITS
3" MIN 7 1/2" 7 1/2" 7 1/2" 7 1/2"
T
W
PULLING IRONS, COORDINATE
LOCATIONS OPPOSITE CONDUIT
ENTRY LOCATIONS
MANHOLE FRAME AND LID AND
OPENING SHOWN DIAGRAMMATICALLY.
LOCATE IN CORNER AS INDICATED ON
PLAN OR AS REQUIRED FOR ACCESS
AS COORDINATED WITH CABLE
PENETRATIONS IN MANHOLE
SECTION VIEW
FINISH GRADE
SLOPE CONDUIT TO
MANHOLE (TYP.)
5/8" x 8'-0" COPPER GROUND ROD. BOND
TO ALL STEEL IN MANHOLE WITH 1-#6 AWG.
BOND TO ALL GROUND CONDUCTORS
ROUTED IN MANHOLE
COORDINATE CONDUIT ENTRY
LOCATIONS WITH SITE PLAN (TYP.)
PROVIDE FIBERGLASS MANHOLE LADDER
FOR ACCESS. COORDINATE LOCATION
WITH MANHOLE FRAME AND LID. PROVIDE
AND INSTALL ALL NECESSARY EQUIPMENT
TO SECURE LADDER TO MANHOLE. REFER
TO SPECIFICATIONS FOR DETAILS
#4 AT 6" O.C. EACH WAY
R-1640 MANHOLE FRAME WITH SOLID LID
MANUFACTURED BY NEENAH FOUNDRY
COMPANY, THE LID SHALL BE MARKED
"TELECOMMUNICATIONS". LID SHALL BE
LOCKABLE.
GROUT
PRE CAST BOTTOM SECTION
#4`S AT 6" O.C. BOTTOM
EACH WAY
#4 TOP AND BOTTOM ON
FOUR SIDES OF OPENING
PROVIDE PRE CAST
EXTENSIONS AS NEEDED
TO REACH GRADE
MINIMUM OF 1/3 CU. YD
OF CRUSHED GRAVEL
2" PVC DRAIN PIPE, SLOPE
DOWN TOWARDS GRAVEL
AWAY FROM THE MANHOLE
DRAIN COVER
TWIST TIMER SWITCH.
FIELD LOCATE NEAR
MANHOLE ENTRANCE,
+48" AFF
REFER TO ELECTRICAL SITE PLANS FOR CIRCUIT
IDENTIFICATION AND PANEL BOARD LOCATION
CAST-IN-PLACE OR
PRE-CAST CONCRETE TOP
PRE CAST TOP SECTION
INSIDE MANHOLE DIMENSIONS
SHALL BE 72"W X 72"Dx 72"H
M
IN
IM
U
M
(1
(1
(7
/2
M
IN
IM
U
M
(6
M
IN
IM
U
M
(36")
(6") (6")
(1
(1
MALLEABLE IRON
BELL END (TYP.)
S
NOTES:
1. DETAIL SHOWN DIAGRAMMATICALLY.REFER TO 0-TG003 FOR MANHOLE LOCATIONS.
2. DETAIL IS TYPICAL OF ALL MANHOLES.
3. A MINIMUM OF 50' OF EACH FIBER CABLE SHALL BE COILED IN EACH MAINTENANCE HOLE.
4. MINIMUM INTERIOR DIMENSIONS OF 72" X 72" X 72".
20'-0" MINIMUM
MARKER TAPE WITH
METALLIC TRACER, 12"
ABOVE DUCT BANK
(4) #4 BARS CONTINUOUS
ON TOP AND BOTTOM
4" (5") SCHEDULE 40 PVC
4" MINIMUM COMPACTED
AGGREGATE BASE.
[PRECAST CONCRETE PADS
ON UNDISTURBED EARTH
UNDER EACH SPACER]
#4 TIE BARS AT 3'-0"
ON CENTER
INTERMEDIATE SPACER
CONDUIT NONMETALLIC SPACER,
MAXIMUM 5' ON CENTER. [CARLON
S288 SERIES, UNDERGROUND
DEVICES WUNPEECE, OSBORN
ASSOCIATES 5100 SERIES]
3" MIN.
M
IN
M
IN
M A
X
/2
/4
2500 PSI CONCRETE
7 1/2" 7 1/2"
CLEAN EARTH
BACKFILL PLACED PER
SPECIFICATIONS
FINISHED GRADE
NONMETALLIC REDUCER SPACER
NOTES:
1. INSTALL 2000 lb TENSILE STRENGTH BRAIDED POLYPROPYLENE
PULL CORD IN ALL CONDUITS.
2. TRENCHING AND BACKFILL ACCORDING TO SPECIFICATIONS.
3. MINIMUM OF 4'-0" CLEAR BETWEEN ADJACENT DUCTBANKS.
4. DOWEL ENDS OF DUCTBANK TO FOUNDATION OR MANHOLE
WITH A MINIMUM OF (4) #4 DOWELS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/T
.0
V A
-C h ill ic o th e
C a m p u s
C .r v t
/6
/2
:3
:2
P M
000-TN500
TECHNOLOGY DETAILS
07/07/2023 ACA ECW
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
BID DOCUMENTS
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
NO SCALE
EXTERIOR HAND HOLE DETAIL
NO SCALE
EXTERIOR WALL PENETRATION DETAIL
NO SCALE
CORE "A" DUCTBANK DETAIL
NO SCALE
CORE "B" DUCTBANK DETAIL
NO SCALE
TELECOMMUNICATIONS MANHOLE DETAIL
NO SCALE
DUCT BANK DETAIL (3x2)
No. Revisions: Date:
BID DOCUMENTS 07/07/2023
Eddie C. Willis, Jr.
REG. NO. 191562R
EXPIRES 12-31-25
REGIS
TE
R
ED
C
O
MMUNICA T IONS DISTRIBUT IO
N
DESIG
NER
S °3 '4 "W
.3
N12°09'33"W 101.51'
S °3 '3 "W
.3
S °3 '5 "W
.7
N °3 '4 "E
.2
S12°12'35"E 618.40'
T41
T40
5 3
F F E
.9
F F E
.9
F F E
.3
F F E
.4
F F E
.0
F F E
.0
F F E
.3
F F E
.7
F F E
.0
F F E
.3
F F E
.7
F F E
.1
F F E
.8
F F E
.3
F F E
.3
F F E
.3
F F E
.8
F F E
.3
F F E
.3
F F E
.5
F F E
.7
F F E
.8
F F E
.9
F F E
.9
F F E
.9
(N O R
TH
S
ID
E
F F E
.9
(S O U
TH
S
ID
E
F F E
.8
F F E
.1
F F E
.9
F F E
.0
F F E
.5
F F E
.8
F F E
.6
F F E
.8
F F E
.5
F F E
.9
F F E
.7
F F E
.5
F F E
.5
F F E
.3
F F E
.8
F F E
.9
F F E
.4
F F E
.4
F F E
.3
F F E
.3
F F E
.6
F F E
.4
F F E
.6
F F E
.1
F F E
.8
F F E
.9
F F E
.0
F F E
.5
F F E
.8
F F E
.7
F F E
.2
F F E
.8
F F E
.8
F F E
.5
F F E
.5
FFE =
661.43
F F E
.3
F F E
.0
F F E
.7
F F E
.1
F F E
.9 7F F E
.7
F F E
.0
F F E
.8
F F E
.3
F F E
.8
F F E
.9
F F E
.9
F F E
.7
F F E
.6
STEPS
T
T
T
T
T
T
T
T T
T T
T T
T T T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T
T T
T
T
P T
T
T
T
T
T
T
T
T
T
T
T T
T
T
T
A
B
B
A
B B
A
A
A A
A A
A
A
A B
B
B B
B
B
B
B
B A
B
B
A
B A
B
A
A
A
A
A
B
B B
35 3
252 24
AB
SHEET NOTES:
1. REFER TO CIVIL PLANS FOR EXACT ROUTING AND
QUANTITIES.
2. DASHED LINES REPRESENT DUCTBANK, CRAWL
SPACE OR UNDERGROUND CONDUITS
3. PROVIDE (3) MAXCELL, 3-POCKET FABRIC
INNERDUCTS (MXE8683) IN EACH 4" CONDUIT.
4. REFER TO 1/TN401 EXTERIOR HAND HOLE DETAIL
FOR ADDITIONAL INFORMATION.
5. REFER TO 2/TN401, EXTERIOR WALL
PENETRATION DETAIL FOR ADDITIONAL
INFORMATION.
6. REFER TO 3/TN401, EXTERIOR PATHWAY DETAIL
FOR ADDITIONAL INFORMATION.
7. REFER TO OPTICAL FIBER AND COPPER RISER
DIAGRAMS ON TN400 FOR ADDITIONAL
INFORMATION.
SP2
A
B
B
A
B A
SP1/SP2
SP2
AB
KEYNOTES:
1. LOCATION OF EXISTING TELECOMMUNICATIONS
MANHOLE AND ASSOCIATED UNDERGROUND
PATHWAY TO DATA CENTER IN BUILDING #18.
MANHOLE CONTAINS BACKBONE OPTICAL FIBER
CABLES FOR BOTH PRIMARY AND SECONDARY
SERVICE PROVIDERS (SP1/SP2).
2. APPROXIMATE LOCATION OF SP2 EXISTING
UNDERGROUND PATHWAYS FROM COMMON
MANHOLE WITH SP1 BACK TO EXISTING SP2
MANHOLE.
3. CONTRACTOR SHALL PROVIDE NEW TELECOM
DUCTBANK FROM EXISTING SP2 MANHOLE
INDICATED AND ROUTE BELOW GRADE AS
SHOWN TO PROVIDE DIVERSE PATHWAY INTO
BUILDING #18.
4. CONTRACTOR SHALL PROVIDE NEW MANHOLE
AT LOCATION INDICATED WITH CONDUIT
DUCTBANK OUT OF BUILDING #18 TO START
"CORE B" BACKBONE CABLE ROUTE.
5. CONTRACTOR SHALL PROVIDE NEW MANHOLE AT
LOCATION INDICATED WITH CONDUIT DUCTBANK
FROM BUILDING #18 AND MANHOLE TO START
"CORE A" BACKBONE CABLE ROUTE.
6. ROUTE CONDUIT DUCTBANK UNDER
EXISTING STAIRS.
7. ROUTE CONDUIT DUCTBANK UNDER
COVERED WALKWAY.
8. ROUTE DUCTBANKS UNDER OUTDOOR PATIO
AND CRAWL SPACE OF BUILDING ADDITION.
9. COORDINATE DUCTBANK ROUTING IN THIS AREA
TO AVOID TREES AND LANDSCAPE MONUMENTS
AND BASEBALL FIELD FENCING.
A-LOOP
B-LOOP
B-LOOP
B -L
O O
P
B-LOOP
A-LOOP
B-LOOP
B -L
O O
P
A -L
O O
P
A-LOOP A-LOOP
B-LOOP
B-LO
O P
A-LOOP
(3) 4"C(2) 4"C
(3) 4"C
(2) 4"C
(2) 4"C (3) 4"C
(2) 4"C
(3) 4"C
(2) 4"C
(3) 4"C
(2) 4"C
(3) 4"C
(2) 4"C
(3) 4"C
(3) 4"C
(2) 4"C
(3) 4"C(2) 4"C
(3) 4"C
(2) 4"C
(3) 4"C
(2) 4"C
(3) 4"C(3) 4"C
(2) 4"C
(2) 4"C
(3) 4"C(3) 4"C
(2) 4"C(2) 4"C
(2) 4"C
(3) 4"C
(3) 4"C
(2) 4"C
(2) 4"C(2) 4"C
(3) 4"C
(2) 4"C
(3) 4"C
(3) 4"C(2) 4"C
(3) 4"C
(2) 4"C
(2) 4"C(3) 4"C
(3) 4"C
(2) 4"C
A -L
O O
P
B-LOOP
A -L
O O
P
B -L
O O
P
B-LOOP
A-LOOP
A -L
O O
P
A
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/T
.0
V A
-C h ill ic o th e
C a m p u s
C .r v t
/6
/2
:3
:2
P M
000-TS100
CAMPUS TECHNOLOGY SITE PLAN
07/07/2023 ACA ECW
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
BID DOCUMENTS
SITE
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
N O R
HT
1" = 110'-0"
CAMPUS TECHNOLOGY SITE PLAN
No. Revisions: Date:
BID DOCUMENTS 07/07/2023
Eddie C. Willis, Jr.
REG. NO. 191562R
EXPIRES 12-31-25
REGIS
TE
R
ED
C
O
MMUNICA T IONS DISTRIBUT IO
N
DESIG
NER
DN
Training Room
BB103
Bowling Alley
BC100B
Game Room
BC100
Tele Clos
BB105
Records Storage
BA110
Mds Records Storage
BA112
Admin Office Academic
Affairs
BA114
Admin Officer Gecl
BA111
Palliative Care
BA109
Associate Chief Nurse
BA107
Palliative Care
Coordination
BA105
Community Health Nurse
BA103
Comm Social Worker
BA108
Corridor
CB3
Pharmacist
BA101A
Nursing Storage
BA102
Elect. Room
BC100F
Elect. Room
BC100E
Vestibule
BC100D
Stair
S1-0
Corridor
CB5
Mechanical
BB106
Toilet
BB107
Corridor
CB4
HAC
BA100
Stair
S2-0
Corridor
CB1
Storage
BB101A
Vet Director Coordinator
BA101B
Gecl Clinical Liason/ Non Va Case Rn
BA101C
Toilet
BA104
Corridor
CB2
Pin Setting Equip
BC100C
Game Room
BC100A
Supply Room
BC100G
Storage
BB102
Cio Equipment
Storage
BB101
Dep Cos
BA116Ao Rehab Services
BA113
Corridor
CB6
Engineering Room
BB104
Tele Clos
BB104A
Storage
BB100
Toilet
BA106
Tele Clos
BA102A
(2) 4"C - (5) 24-STRAND OS2 OPTICAL
FIBER AND (5) 25-PAIR COPPER CABLES
AND (1) 4”C - SPARE
(1) 4"C - (5) 24-STRAND OS2
OPTICAL FIBER CABLES
AND (1) 4”C -SPARE
BA
OUTLINE OF TR #139
AT FLOOR ABOVE
OUTLINE OF TR #179
AT FLOOR ABOVE
HANDHOLE
HANDHOLE
(1) 4"C - (1) 24-STRAND OS2
OPTICAL FIBER CABLE
(2) 4"C - (1) 24-STRAND OS2
OPTICAL FIBER AND
25-PAIR COPPER CABLES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD…