Attachment 08 - SOW attach Volume 1 Part 3.pdf
PDF 9 MB Posted
- Attached to
- Y1DA--538-21-701 EHRM Infrastructure Upgrades Construction Chillicothe, OH (VA-23-00066755)
- Solicitation number
- 36C77623B0058
About this file
This package of construction drawings and specifications is for infrastructure upgrades at the Chillicothe VA Medical Center in Chillicothe, Ohio. The project involves renovations and upgrades to buildings 1, 3, 7, 18, 21, 23, and 24, including electrical, mechanical and telecommunications work. Key work includes installing new partitions, doors, flooring and ceilings in various rooms, upgrading telecommunications closets, and modifying spaces to accommodate new uses. The solicitation number for this project is 36C77623B0058, issued by the Department of Veterans Affairs Technology Acquisition Center in Austin, Texas. The estimated period of performance is 11 months from the award date. Pricing will be fixed-price, and the contract has no set-aside provisions.
View the file
Other files
Show 40 more
Latest 50 of 65 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROFILE VIEW OF FOC BLDG 25 A
HORIZONTAL SCALE: 1" = 20'
VERTICAL SCALE: 1" = 5'
PROFILE VIEW OF FOC BLDG 25 B
HORIZONTAL SCALE: 1" = 20'
VERTICAL SCALE: 1" = 5'
PROFILE VIEW OF FOC BLDG 21 A
HORIZONTAL SCALE: 1" = 20'
VERTICAL SCALE: 1" = 5'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RJJ LKSNo. Revisions: Date:
NOT FOR CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
612-20-101
CHILLICOTHE, OH
CONSTRUCTION
DOCUMENTS - 95%
04/14/2023
CHILLICOTHE
VAMC
DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022
DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022
SCHEMATIC DESIGN - 35% 07/18/2022
DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023
CU211
FIBER P-P BUILDINGS B01
PROFILE VIEW OF FOC BLDG 36 A
VERTICAL SCALE: 1" = 5'
PROFILE VIEW OF FOC BLDG 36 B
HORIZONTAL SCALE: 1" = 20'
VERTICAL SCALE: 1" = 5'
PROFILE VIEW OF FOC BLDG 21 B
HORIZONTAL SCALE: 1" = 20'
VERTICAL SCALE: 1" = 5'
Tripp Street
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RJJ LKSNo. Revisions: Date:
NOT FOR CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
612-20-101
CHILLICOTHE, OH
CONSTRUCTION
DOCUMENTS - 95%
04/14/2023
CHILLICOTHE
VAMC
DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022
DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022
SCHEMATIC DESIGN - 35% 07/18/2022
DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023
CU212
FIBER P-P BUILDINGS B02
PROFILE VIEW OF FOC BLDG 23 B
VERTICAL SCALE: 1" = 5'
PROFILE VIEW OF FOC BLDG 20 A
HORIZONTAL SCALE: 1" = 20'
VERTICAL SCALE: 1" = 5'
Tripp Street Tripp Street
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RJJ LKSNo. Revisions: Date:
NOT FOR CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
612-20-101
CHILLICOTHE, OH
CONSTRUCTION
DOCUMENTS - 95%
04/14/2023
CHILLICOTHE
VAMC
DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022
DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022
SCHEMATIC DESIGN - 35% 07/18/2022
DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023
CU213
FIBER P-P BUILDINGS B03
PROFILE VIEW OF FOC BLDG 20 B
VERTICAL SCALE: 1" = 5'
PROFILE VIEW OF FOC BLDG 259 A
HORIZONTAL SCALE: 1" = 20'
VERTICAL SCALE: 1" = 5'
Tripp Street
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RJJ LKSNo. Revisions: Date:
NOT FOR CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
612-20-101
CHILLICOTHE, OH
CONSTRUCTION
DOCUMENTS - 95%
04/14/2023
CHILLICOTHE
VAMC
DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022
DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022
SCHEMATIC DESIGN - 35% 07/18/2022
DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023
CU214
FIBER P-P BUILDINGS B04
PROFILE VIEW OF FOC BLDG 261 A
VERTICAL SCALE: 1" = 5'
PROFILE VIEW OF FOC BLDG 261 B
HORIZONTAL SCALE: 1" = 20'
VERTICAL SCALE: 1" = 5'
PROFILE VIEW OF FOC BLDG 259 B
HORIZONTAL SCALE: 1" = 20'
VERTICAL SCALE: 1" = 5'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RJJ LKSNo. Revisions: Date:
NOT FOR CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
612-20-101
CHILLICOTHE, OH
CONSTRUCTION
DOCUMENTS - 95%
04/14/2023
CHILLICOTHE
VAMC
DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022
DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022
SCHEMATIC DESIGN - 35% 07/18/2022
DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023
CU215
FIBER P-P BUILDINGS B05
PROFILE VIEW OF FOC BLDG 60 A
VERTICAL SCALE: 1" = 5'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RJJ LKSNo. Revisions: Date:
NOT FOR CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
612-20-101
CHILLICOTHE, OH
CONSTRUCTION
DOCUMENTS - 95%
04/14/2023
CHILLICOTHE
VAMC
DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022
DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022
SCHEMATIC DESIGN - 35% 07/18/2022
DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023
CU216
FIBER P-P BUILDINGS B06
PROFILE VIEW OF FOC BLDG 60 A
VERTICAL SCALE: 1" = 5'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RJJ LKSNo. Revisions: Date:
NOT FOR CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
612-20-101
CHILLICOTHE, OH
CONSTRUCTION
DOCUMENTS - 95%
04/14/2023
CHILLICOTHE
VAMC
DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022
DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022
SCHEMATIC DESIGN - 35% 07/18/2022
DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023
CU217
FIBER P-P BUILDINGS B07
PROFILE VIEW OF FOC BLDG 60 B
VERTICAL SCALE: 1" = 5'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RJJ LKSNo. Revisions: Date:
NOT FOR CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
612-20-101
CHILLICOTHE, OH
CONSTRUCTION
DOCUMENTS - 95%
04/14/2023
CHILLICOTHE
VAMC
DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022
DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022
SCHEMATIC DESIGN - 35% 07/18/2022
DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023
CU218
FIBER P-P BUILDINGS B08
PROFILE VIEW OF FOC BLDG 60 B
VERTICAL SCALE: 1" = 5'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RJJ LKSNo. Revisions: Date:
NOT FOR CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
612-20-101
CHILLICOTHE, OH
CONSTRUCTION
DOCUMENTS - 95%
04/14/2023
CHILLICOTHE
VAMC
DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022
DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022
SCHEMATIC DESIGN - 35% 07/18/2022
DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023
CU219
FIBER P-P BUILDINGS B09
PROFILE VIEW OF FOC BLDG 247 B
VERTICAL SCALE: 1" = 5'
PROFILE VIEW OF FOC BLDG 247 A
HORIZONTAL SCALE: 1" = 20'
VERTICAL SCALE: 1" = 5'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RJJ LKSNo. Revisions: Date:
NOT FOR CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
612-20-101
CHILLICOTHE, OH
CONSTRUCTION
DOCUMENTS - 95%
04/14/2023
CHILLICOTHE
VAMC
DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022
DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022
SCHEMATIC DESIGN - 35% 07/18/2022
DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023
CU220
FIBER P-P BUILDINGS B10
PROFILE VIEW OF FOC BLDG 31 A
VERTICAL SCALE: 1" = 5'
PROFILE VIEW OF FOC BLDG 31 B
HORIZONTAL SCALE: 1" = 20'
VERTICAL SCALE: 1" = 5'
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RJJ LKSNo. Revisions: Date:
NOT FOR CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
612-20-101
CHILLICOTHE, OH
CONSTRUCTION
DOCUMENTS - 95%
04/14/2023
CHILLICOTHE
VAMC
DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022
DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022
SCHEMATIC DESIGN - 35% 07/18/2022
DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023
CU221
FIBER P-P BUILDINGS B11
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
RJJ LKSNo. Revisions: Date:
NOT FOR CONSTRUCTION
EHRM INFRASTRUCTURE
UPGRADES
612-20-101
CHILLICOTHE, OH
CONSTRUCTION
DOCUMENTS - 95%
04/14/2023
CHILLICOTHE
VAMC
DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022
DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022
SCHEMATIC DESIGN - 35% 07/18/2022
DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023
CONCRETE HEADER3
MOUNTABLE CONCRETE CURB AND GUTTER4
CONCRETE CURB AND TERMINAL SECTION2
TYPE 2 UTILITY TRENCH PATCH5 TYPE 3 UTILITY TRENCH PATCH6
GENERAL NOTES
PCC SIDEWALK DETAIL1
PLACE CONCRETE BLOCK
OR OTHER DEVICE TO
PREVENT TUBE FROM
PLUGGING INTAKE
OVERLAP TUBE 1' AND SECURE
WITH WIRE OR WIRE TIES
UNDISTRIBUTED
GROUND
FILTER CLOTH
16" MIN. HEIGHT
OF FILTER CLOTH
0"
M
IN
0"
M
IN
8" M
IN EMBED FILTER CLOTH MIN.
10" INTO GROUND
48" MIN. FENCE POST
ROLL WITH TRACTOR
TIRE 1-4 TIMES
STATIC SLICE INSTALLATION
PERIMETER SEDIMENT CONTROL NOTES:
1. FENCE POST TO BE STEEL "T" OR "U" TYPE OR 2" HARDWOOD. FENCE POSTS
ARE TO BE DRIVEN INTO GROUND 18" MIN. AT 10' MAXIMUM SPACING.
2. FILTER CLOTH TO BE FILTER X, MIRAFI 100X, STABILINKA T140N. CLOTH TO BE
FASTENED SECURELY TO FENCE POSTS. WHEN TWO SECTIONS OF FILTER
CLOTH ADJOIN EACH OTHER THEY SHALL BE OVERLAPPED BY 6" AND FOLDED.
3. MAINTENANCE SHALL BE PERFORMED AS NEEDED AND MATERIAL REMOVED
WHEN "BULGES" DEVELOP IN THE SILT FENCE.
PERIMETER SEDIMENT CONTROL DETAIL
FILTER TUBES USED FOR INLET PROTECTION8
CK101
CIVIL DETAILS
UP UP
DN
ZONE 1
ZONE 3ZONE 2
ZONE 5ZONE 4
001-AE100.1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
NOT FOR CONSTRUCTION
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:5
:4
P
M
001-AE100
OVERALL BASMENT FLOOR PLAN
03/17/2023 PQ JF
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
CONSTRUCTION
DOCUMENTS - 95% 001
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
No. Revisions: Date:
CONSTRUCTION DOCUMENTS - 95% 04/14/2023
N
1" = 10'-0"
BUILDING 1 - BASEMENT FLOOR PLAN
001-AE100.1
Training Room
BB103
Game Room
BC100A
Storage
BB102
TELECOMM. ROOM
BB105
Cio Equipment Storage
BB101
Stair
S1-0
Corridor
CB6
Corridor
CB5
Engineering Room
BB104
Mechanical
BB106
Tele Clos
BB104A
Toilet
BB107
Corridor
CB4
Stair
S2-0Storage
BB100
Corridor
CB1
Storage
BB101A
2 - 5
TELECOMM. ROOM
BB105
BB105
TELECOMM. ROOM
BB105
TELECOMM. ROOM
BB105
BB105
TELECOMM. ROOM
BB105
A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.
B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.
G E N E R A L D E M O L I T I O N N O T E S
G E N E R A L C O N S T R U C T I O N N O T E S
A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.
B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.
C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED
OTHERWISE.
D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER
MANUFACTURER'S WRITTEN INSTRUCTIONS.
E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE
ACCORDINGLY.
F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.
G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.
H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO
MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.
I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.
J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED
OTHERWISE.
K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE
STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.
L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A
PARTITION BRACING ELEMENT.
M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.
N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER
REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.
O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION
P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.
S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED
WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
NOT FOR CONSTRUCTION
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:5
:0
P
M
001-AE100.1
BASEMENT FLOOR PLAN - ZONE 1
03/17/2023 PQ JF
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
CONSTRUCTION
DOCUMENTS - 95% 001
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
No. Revisions: Date:
CONSTRUCTION DOCUMENTS - 95% 04/14/2023
1/8" = 1'-0"
BASEMENT FLOOR PLAN - ZONE 1
1/4" = 1'-0"
DEMO - TR LOCATION FLOOR PLAN
1/4" = 1'-0"
DEMO - TR LOCATION RCP
1/4" = 1'-0"
NEW WORK - TR LOCATION FLOOR PLAN
1/4" = 1'-0"
NEW WORK - TR LOCATION RCP
D R A W I N G N O T E S :
1 REMOVE EXISTING DOOR FRAME AND DOOR LEAF; TURN DOOR LEAF OVER TO VA TO ADD TO EXISTING STOCK.
2 REMOVE EXISTING FLOORING FINISH AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR
INSTALLATION OF ELECTRIC DISSIPATING FLOORING DURING CONSTRUCTION.
3 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND
CONDUIT. PAINT WHITE ALL BUT FIRE RATING LABEL.
4 EXISTING MOUNTED PLYWOOD TO REMAIN, TYPICAL.
5 INSTALL ELECTRICAL DISSIPATING FLOOR PAINT - SEE HATCHED AREA
6 WINDOW SECURITY BARS - INSTALLED ON INTERIOR OF WINDOW OPENING
7 REMOVE WALL BASE ALONG THIS WALL - LEADER ARROW POINTS TO WALL SURFACE
8 INSTALL WALL BASE ALONG WALL
9 MOUNT AND PROVIDE NEW ABC FIRE EXTINGUISHER
10 REMOVE ALL PAINT AND DEBRIS FROM WALL. AREA IDENTIFIED BY DASHED LINE.
11 PAINT WALLS - REFER TO FINISH SCHEDULE
12 NO CEILING IN THIS AREA
DN DNDN
ZONE 1
ZONE 3ZONE 2
ZONE 5ZONE 4
001-AE101.1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
NOT FOR CONSTRUCTION
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:5
:1
P
M
001-AE101
OVERALL FIRST FLOOR PLAN
03/17/2023 PQ JF
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
CONSTRUCTION
DOCUMENTS - 95% 001
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
No. Revisions: Date:
CONSTRUCTION DOCUMENTS - 95% 04/14/2023
1" = 10'-0"
BUILDING 1 - FIRST FLOOR PLAN
UP
Toilet
Voucher Examiner & Employee Travel
Conference Room
Contract Specialist
Contract Spec Intern
Supply Tech
Chief Acquisitions/ Contracting
Contract Liason
Contract Specialist
Contract Specialists
Admin Support Assist
Chief Logistics
Chief Inventory Supply Support
Inventory Management Spec
Item Manager
Item Manager
Item Manager
Xerox/supplies
Toilet
Files Storage
TR
Corridor
1C002
Corridor
1C006
Stair
S1-1
001-AE101.2
22 - 5
A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.
B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.
G E N E R A L D E M O L I T I O N N O T E S
G E N E R A L C O N S T R U C T I O N N O T E S
A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.
B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.
C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED
OTHERWISE.
D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER
MANUFACTURER'S WRITTEN INSTRUCTIONS.
E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE
ACCORDINGLY.
F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.
G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.
H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO
MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.
I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.
J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED
OTHERWISE.
K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE
STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.
L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A
PARTITION BRACING ELEMENT.
M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.
N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER
REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.
O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION
P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.
S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED
WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.
Files Storage
TR
Files Storage
TR
9 10
Files Storage
98 SF
TR
TR
Files Storage
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
NOT FOR CONSTRUCTION
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:5
:3
P
M
001-AE101.2
FIRST FLOOR PLAN - ZONE 2
03/17/2023 Checker Author
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
CONSTRUCTION
DOCUMENTS - 95%CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
No. Revisions: Date:
CONSTRUCTION DOCUMENTS - 95% 04/14/2023
1/8" = 1'-0"
FIRST FLOOR PLAN - ZONE 1
D R A W I N G N O T E S :
1 REMOVE WALL
2 NO CEILING IN THIS AREA
3 MOUNT AND PROVIDE NEW ABC FIRE EXTINGUISHER
4 INSTALL ELECTRICAL DISSIPATING FLOOR PAINT - SEE HATCHED AREA
5 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND
CONDUIT. PAINT WHITE ALL BUT FIRE RATING LABEL.
6 WINDOW SECURITY BARS - INSTALLED ON INTERIOR OF WINDOW OPENING
7 REMOVE CEILING SYSTEMS AND SUPPORTS
8 REMOVE CEILING GRID AND ACOUSTICAL TILES. LEAVE CEILING GRID SUPPORTS FOR INSTALLATION OF NEW GRID AND
TILES.
9 PAINT WALLS - REFER TO FINISH SCHEDULE
10 INSTALL WALL BASE, MATCH EXISTING BASE.
1/4" = 1'-0"
B01 - FIRST FLOOR PLAN - ZONE 1
1/4" = 1'-0"
B01 - FIRST FLOOR PLAN - ZONE 1
1/4" = 1'-0"
B01 - FIRST FLOOR - ZONE 2 - TR - NEW RCP
1/4" = 1'-0"
B01 - FIRST FLOOR - ZONE 2 - TR - DEMO RCP
DN DNDN
001-AE101.1
Risk Manager
Performance Measure Coordinator
Patient Safety
External Review Manager
Contracting Liason Office
Toilet
Filing Supplies
Utilization Nurse
HAC
Performance Measure Coordinator
Program Support Assistant
Systems Design Coordinator
HAC
Copy Room
Break Room
TR
Quality Improvement Facilitator
Quality Manager
QI Program Asst
Waiting
1L001
Corridor
1C002
Waiting
1L002
Corridor
1C007
Stair
S2-1
Stair
S1-1
2 - 5
Eeo Manage
TR
1L002
Eeo Manage
TR
A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.
B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.
G E N E R A L D E M O L I T I O N N O T E S
G E N E R A L C O N S T R U C T I O N N O T E S
A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.
B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.
C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED
OTHERWISE.
D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER
MANUFACTURER'S WRITTEN INSTRUCTIONS.
E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE
ACCORDINGLY.
F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.
G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.
H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO
MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.
I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.
J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED
OTHERWISE.
K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE
STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.
L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A
PARTITION BRACING ELEMENT.
M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.
N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER
REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.
O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION
P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.
S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED
WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
NOT FOR CONSTRUCTION
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:5
:2
P
M
001-AE101.1
FIRST FLOOR PLAN - ZONE 1
03/17/2023 PQ JF
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
CONSTRUCTION
DOCUMENTS - 95% 001
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
No. Revisions: Date:
CONSTRUCTION DOCUMENTS - 95% 04/14/2023
1/8" = 1'-0"
FIRST FLOOR PLAN - ZONE 1
1/4" = 1'-0"
ROOM 179 - DEMOLITION FLOOR PLAN
1/4" = 1'-0"
ROOM 179 - FLOOR PLAN
D R A W I N G N O T E S :
1 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND
CONDUIT. PAINT WHITE ALL BUT FIRE RATING LABEL.
2 REMOVE EXISTING FLOORING FINISH AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR
INSTALLATION OF ELECTRIC DISSIPATING FLOORING DURING CONSTRUCTION.
3 REMOVE CEILING SYSTEMS AND SUPPORTS
4 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND
CONDUIT. PAINT WHITE ALL BUT FIRE RATING LABEL.
5 INSTALL ELECTRICAL DISSIPATING FLOOR PAINT - SEE HATCHED AREA
6 WINDOW SECURITY BARS - INSTALLED ON INTERIOR OF WINDOW OPENING
7 NO CEILING IN THIS AREA
8 REMOVED AND REPLACE FRAME AND LOCKSET AS REQUIRED FOR CARD READER. REUSE REMAINING HARDWARE
9 MOUNT AND PROVIDE NEW ABC FIRE EXTINGUISHER
10 REMOVE PACKAGED THERMAL UNIT
1/4" = 1'-0"
B01 - FIRST FLOOR - ZONE 1 - TR - DEMO RCP
1/4" = 1'-0"
B01 - FIRST FLOOR - ZONE 1 - TR - NEW RCP
DN
UP
D
EM
D
D
EM
D
EM
D
EM
D
D
D
EM
EM
D
D
D
EM
E M
D
D
E M
D
ZONE 1
ZONE 3ZONE 2
ZONE 5ZONE 4
001-AE102.1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
NOT FOR CONSTRUCTION
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:5
:4
P
M
001-AE102
OVERALL SECOND FLOOR PLAN
03/17/2023 PQ JF
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
CONSTRUCTION
DOCUMENTS - 95% 001
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
No. Revisions: Date:
CONSTRUCTION DOCUMENTS - 95% 04/14/2023
N
1" = 10'-0"
B01 - SECOND FLOOR - OVERALL
190 SF
Toilet
Toilet
9 SF
Elect. Room
196 SF
Piv Room
197 SF
Regional Counsel Conf
Regional Counsel Library
Hr Assistants
Copy/mail Room
Hrm Office
Intern Office
Hrm Office
Resource Room
Hrm Specalists
Vet Pro
Hrm Office
Hrm Office
Hrm Office
Tele Clos
Employee Resources
Regional Counsel Office
224A
Corridor
2C5
Regional Counsel Office
224B
Tele Clos
Stair
S1-2
Corridor
2C003
302 SF
Corridor
2C002
155 SF
Corridor
2C3
HMR ASSISTANT
238 001-AE102.2
22 - 5
A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.
B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.
G E N E R A L D E M O L I T I O N N O T E S
G E N E R A L C O N S T R U C T I O N N O T E S
A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.
B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.
C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED
OTHERWISE.
D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER
MANUFACTURER'S WRITTEN INSTRUCTIONS.
E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE
ACCORDINGLY.
F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.
G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.
H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO
MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.
I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.
J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED
OTHERWISE.
K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE
STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.
L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A
PARTITION BRACING ELEMENT.
M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.
N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER
REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.
O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION
P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.
S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED
WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.
Tele Clos
HMR ASSISTANT
REMOVE FLOORING BOUNDARY
Tele Clos
HMR ASSISTANT
5 6
7 8
HMR ASSISTANT
Tele Clos
HMR ASSISTANT
Tele Clos
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
NOT FOR CONSTRUCTION
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:5
:1
P
M
001-AE102.2
SECOND FLOOR PLAN - ZONE 2
03/17/2023 Checker Author
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
CONSTRUCTION
DOCUMENTS - 95%CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
No. Revisions: Date:
CONSTRUCTION DOCUMENTS - 95% 04/14/2023
N
1/8" = 1'-0"
B01 - SECOND FLOOR PLAN - ZONE 2
D R A W I N G N O T E S :
1 REMOVE EXISTING FLOORING FINISH AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR
INSTALLATION OF ELECTRIC DISSIPATING FLOORING DURING CONSTRUCTION.
2 REMOVE WALL
3 NEW WALL - REFER TO GI001 FOR WALL TYPE DETAIL - 1 HR FIRE RATING
4 INSTALL ELECTRICAL DISSIPATING FLOOR PAINT - SEE HATCHED AREA
5 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND
CONDUIT. PAINT WHITE ALL BUT FIRE RATING LABEL.
6 WINDOW SECURITY BARS - INSTALLED ON INTERIOR OF WINDOW OPENING
7 PAINT WALLS - REFER TO FINISH SCHEDULE
8 INSTALL WALL BASE ALONG WALL
1/4" = 1'-0"
B01 - SECOND FLOOR PLAN - ZONE 2 - TR - DEMO PLAN
1/4" = 1'-0"
B01 - SECOND FLOOR PLAN - ZONE 2 - TR - NEW PLAN
1/4" = 1'-0"
B01 - SECOND FLOOR PLAN - ZONE 2 - TR - DEMO RCP
1/4" = 1'-0"
B01 - SECOND FLOOR PLAN - ZONE 2 - TR - NEW WORK RCP
DN
UP
001-AE102.1
22 - 5
Health Systems Spec Pcs
Emergency Preparedness Coordinator
Patient Business Intern
Assistant Patient Business Manager
Customer Service Coordinator
Toilet
Dss Liason
Interior Designer
Conference/Training
Facility Telehealth Coordinator
HAC
Break Room
Toilet
Training Room
Training Room
Patient Business Service Manager
245A
Heart Code Room
Stair
S1-2
Stair
S2-2
Corridor
2C002
Corridor
2C001 Corridor
2C006
Corridor
2C005
TR
284B
TR
284B
10' - 5"
R E
M O
V E
F
LO
O
R
IN
G B
O U
N D
A R
Y
TRAINING ROOM
TRAINING ROOM
10' - 5"
TR
284B
284B
TRAINING ROOM
A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.
B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.
G E N E R A L D E M O L I T I O N N O T E S
G E N E R A L C O N S T R U C T I O N N O T E S
A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.
B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.
C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED
OTHERWISE.
D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER
MANUFACTURER'S WRITTEN INSTRUCTIONS.
E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE
ACCORDINGLY.
F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.
G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.
H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO
MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.
I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.
J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED
OTHERWISE.
K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE
STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.
L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A
PARTITION BRACING ELEMENT.
M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.
N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER
REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.
O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION
P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.
S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED
WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
NOT FOR CONSTRUCTION
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:5
:0
P
M
001-AE102.1
SECOND FLOOR PLAN - ZONE 1
03/17/2023 PQ JF
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
CONSTRUCTION
DOCUMENTS - 95% 001
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
No. Revisions: Date:
CONSTRUCTION DOCUMENTS - 95% 04/14/2023
N
1/8" = 1'-0"
B01 - SECOND FLOOR PLAN - ZONE 1
1/4" = 1'-0"
B01 - SECOND FLOOR PLAN - ZONE 1 - TR - NEW WORK RCP
1/4" = 1'-0"
B01 - SECOND FLOOR PLAN - ZONE 1 - TR - DEMO PLAN
1/4" = 1'-0"
B01 - SECOND FLOOR PLAN - ZONE 1 - TR - NEW WORK PLAN
1/4" = 1'-0"
B01 - SECOND FLOOR PLAN - ZONE 1 - TR - DEMO RCP
D R A W I N G N O T E S :
1 REMOVE EXISTING FLOORING FINISH AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR
INSTALLATION OF ELECTRIC DISSIPATING FLOORING DURING CONSTRUCTION.
2 WINDOW SECURITY BARS - INSTALLED ON INTERIOR OF WINDOW OPENING
3 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND
CONDUIT. PAINT WHITE ALL BUT FIRE RATING LABEL.
4 INSTALL ELECTRICAL DISSIPATING FLOOR PAINT - SEE HATCHED AREA
5 REMOVE EXISTING DOOR FRAME AND DOOR LEAF; TURN DOOR LEAF OVER TO VA TO ADD TO EXISTING STOCK.
6 REMOVE CEILING SYSTEMS AND SUPPORTS WHERE FUTURE TR IS. LEAVE CEILING SUPPORTS IN ADJACENT SPACE THAT
WILL NEED TO HAVE CEILING INSTALLED AND TIED INTO EXISTING CEILING GRID.
7 NO CEILING IN THIS AREA
8 INSTALL NEW CEILING COMPONENTS TO TIE EXISTING CEILING SYSTEM TO NEW WALL - MATCH EXISTING GRID
COMPONENTS AND ACOUSTICAL CEILING TILES
9 NEW WALL - REFER TO GI001 FOR WALL TYPE DETAIL - 1 HR FIRE RATING
10 INSTALL WALL BASE, MATCH EXISTING BASE.
ZONE 1
ZONE 2
ZONE 4 ZONE 5
ZONE 3
003-AE101.1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
NOT FOR CONSTRUCTION
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:5
:1
P
M
003-AE101
OVERALL FIRST FLOOR PLAN
03/17/2023 PQ JF
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
CONSTRUCTION
DOCUMENTS - 95% 003
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
No. Revisions: Date:
CONSTRUCTION DOCUMENTS - 95% 04/14/2023
N
1" = 10'-0"
B03 - FIRST FLOOR PLAN - OVERALL
003-AE101.1
Supply
106C
HAC
106E
Toilet
106F
Toilet
106G
Corridor
C1-3
Corridor
C1-1
Vet Rep
107A
Day Treatment Office
Program Assistant
Forms Storage
110A
Elect. Room
111A
Toilet
TR
Office
Incentive Therapy
Vestibule
Office
100G
Office
100E
Office
100F
Stair
S2-1
Stair
S1-1
Elect. Room
100A
Office
100H
Office
100D
Supply
100B
Office
100C
Corridor
Existing Dark Room
106A
Waiting
Corridor
106B
Veteran's Industries Marketing
Corridor
C1-2
2 - 5
TR
TR
TR
TR
A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.
B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.
G E N E R A L D E M O L I T I O N N O T E S
G E N E R A L C O N S T R U C T I O N N O T E S
A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.
B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.
C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED
OTHERWISE.
D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER
MANUFACTURER'S WRITTEN INSTRUCTIONS.
E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE
ACCORDINGLY.
F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.
G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.
H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO
MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.
I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.
J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED
OTHERWISE.
K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE
STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.
L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A
PARTITION BRACING ELEMENT.
M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.
N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER
REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.
O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION
P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.
S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED
WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
NOT FOR CONSTRUCTION
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:5
:2
P
M
003-AE101.1
FIRST FLOOR PLAN - ZONE 1
03/17/2023 PQ JF
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
CONSTRUCTION
DOCUMENTS - 95% 003
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
No. Revisions: Date:
CONSTRUCTION DOCUMENTS - 95% 04/14/2023
N
1/8" = 1'-0"
B03 - FIRST FLOOR PLAN - ZONE 1
1/4" = 1'-0"
B03 - FIRST FLOOR PLAN - ZONE 1 - TR - DEMO PLAN
1/4" = 1'-0"
B03 - FIRST FLOOR PLAN - ZONE 1 - TR - NEW WORK PLAN
1/4" = 1'-0"
B03 - FIRST FLOOR PLAN - ZONE 1 - TR - DEMO RCP
1/4" = 1'-0"
B03 - FIRST FLOOR PLAN - ZONE 1 - TR - DEMO RCP
D R A W I N G N O T E S :
1 REMOVE EXISTING FLOORING FINISH AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR
INSTALLATION OF ELECTRIC DISSIPATING FLOORING DURING CONSTRUCTION.
2 REMOVE CEILING SYSTEMS AND SUPPORTS
3 INSTALL ELECTRICAL DISSIPATING FLOOR PAINT - SEE HATCHED AREA
4 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND
CONDUIT. PAINT WHITE ALL BUT FIRE RATING LABEL.
5 WINDOW SECURITY BARS - INSTALLED ON INTERIOR OF WINDOW OPENING
6 MOUNT AND PROVIDE NEW ABC FIRE EXTINGUISHER
7 NO CEILING IN THIS AREA
Uniform/PAP Work Room
108K2
PAP Storage
108K3
Toilet
108K4
PAP Storage
108K1
Uniform Drop-off
108K
Toilet
108J
Vestibule
108V2
Corridor
108L
Serving Line/Dining Area
Chief Dietetics
106A
Vestibule
108V1
Dietetics Secretary
106B
Conference Room
Mechanical
106H
Entry
106I
Delivery/Entry
105B
Cart Room
Office
106E
Office
106F
Office
106G Office
106D
HAC
105A
Elect. Room
107A
Toilet
106C
Tele Clos
106K
Closet
106J
Kitchen
104A
Kitchen
Supervisor's Office
Stair 2
S-2-1
Office
Toilet
Freezer
Corridor
Entry Corridor
HAC
115A
Mechanical
109A
Freezer
Dishwashing
109Toilet
Toilet
Vestibule
108V4
Tray Line Assembly
108C
Corridor
109D
HAC
109B Dishwashing
Dietician Office
108F
Toilet
108A
Toilet
108B
TR
108D
Soiled Utility
108G Clean Linen
108H
HAC
108E
Ingredient Control
Refrigerator
118BFreezer
118C
Entry
Stair 1
S-1-1
Toilet
120B
Closet
120C
Office
120A
Freezer
118E
Refrigerator
118D
Vestibule
108V3
Office
120D
Mechanical/Generator Room
109CDock
104B
Closet
105C
Corridor
007-AE101
22 - 5
108G
Soiled Utility
TELE. CLOSET
108D
108D
TR
108D
108G
Soiled Utility
TELE. CLOSET
108D
TR
108D
A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.
B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.
G E N E R A L D E M O L I T I O N N O T E S G E N E R A L C O N S T R U C T I O N N O T E S
A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.
B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.
C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED
OTHERWISE.
D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER
MANUFACTURER'S WRITTEN INSTRUCTIONS.
E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE
ACCORDINGLY.
F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.
G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.
H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO
MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.
I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.
J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED
OTHERWISE.
K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE
STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.
L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A
PARTITION BRACING ELEMENT.
M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.
N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER
REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.
O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION.
P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.
S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED
WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
NOT FOR CONSTRUCTION
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:5
:4
P
M
007-AE101
OVERALL FIRST FLOOR PLAN
03/17/2023 PQ JF
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
CONSTRUCTION
DOCUMENTS - 95% 007
CHILLICOTHE
VAMC
Approved: Veteran's Affairs Medical Center
No. Revisions: Date:
CONSTRUCTION DOCUMENTS - 95% 04/14/2023
N
1" = 10'-0"
B07 - FIRST FLOOR PLAN - OVERALL
1/4" = 1'-0"
B07 - FIRST FLOOR PLAN - TR - DEMO PLAN
1/4" = 1'-0"
B07 - FIRST FLOOR PLAN - TR - NEW WORK PLAN
1/4" = 1'-0"
B07 - FIRST FLOOR PLAN - TR - DEMO RCP
1/4" = 1'-0"
B07 - FIRST FLOOR PLAN - TR - NEW WORK RCP
D R A W I N G N O T E S :
1 REMOVE EXISTING FLOORING FINISH AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR
INSTALLATION OF ELECTRIC DISSIPATING FLOORING DURING CONSTRUCTION.
2 REMOVE WALL
3 REMOVE CEILING SYSTEMS AND SUPPORTS
4 EXISTING MOUNTED PLYWOOD TO REMAIN, TYPICAL.
5 INSTALL ELECTRICAL DISSIPATING FLOOR PAINT - SEE HATCHED AREA
6 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND
CONDUIT. PAINT WHITE ALL BUT FIRE RATING LABEL.
7 REMOVE WALL BASE ALONG THIS WALL - LEADER ARROW POINTS TO WALL SURFACE
8 MOUNT AND PROVIDE NEW ABC FIRE EXTINGUISHER
D R A W I N G N O T E S :
DN DN
UP
DN
Lobby
Auditorium
Elevator Lobby
Volunteer Work Room
110American Legion Aux
Activities Aide
Activities Aide
Corridor
4M
Closet
Stair
S2-1
Storage
105A
Storage
105B
Lobby
Chair Storage
Vestibule
101A
Lounge
HAC
Stair
S1 Toilet
Toilet
103A
HAC
Corridor
101B
009-AE101
22 - 5
Volunteer Work Room
CLOSET
/8
9' - 10 7/8"
DEMOLITION BOUNDARY
Volunteer Work Room
TR
9' - 6"
CLOSET
Volunteer Work Room
TR
A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.
B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.
G E N E R A L D E M O L I T I O N N O T E S G E N E R A L C O N S T R U C T I O N N O T E S
A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.
B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.
C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED
OTHERWISE.
D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER
MANUFACTURER'S WRITTEN INSTRUCTIONS.
E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE
ACCORDINGLY.
F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.
G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.
H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO
MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.
I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.
J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED
OTHERWISE.
K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE
STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.
L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A
PARTITION BRACING ELEMENT.
M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.
N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER
REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.
O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION.
P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.
SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.
R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.
S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED
WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
VA FORM 08 - 6231
A
FULLY SPRINKLERED
U.S. Department of Veterans Affairs
B
C
D
E
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
NOT FOR CONSTRUCTION
A u to d e s k D o c s /C h ill ic o th e V
A
E H
R M
/F F
E
C h ill ic o th e
E H
R M
C a m p u s rv t
/1
/2
:0
:0
P
M
009-AE101
OVERALL FIRST FLOOR PLAN
03/17/2023 PQ JF
EHRM INFRASTRUCTURE
UPGRADES
538-21-701
CHILLICOTHE, OHIO
CONSTRUCTION
DOCUMENTS - 95% 009
CHILLICOTH…
This is the start of the file's text. The full file is on GovTribe.