Attachment 08 - SOW attach Volume 1 Part 3.pdf

PDF 9 MB Posted

Attached to
Y1DA--538-21-701 EHRM Infrastructure Upgrades Construction Chillicothe, OH (VA-23-00066755)
Solicitation number
36C77623B0058
Issued by

About this file

This package of construction drawings and specifications is for infrastructure upgrades at the Chillicothe VA Medical Center in Chillicothe, Ohio. The project involves renovations and upgrades to buildings 1, 3, 7, 18, 21, 23, and 24, including electrical, mechanical and telecommunications work. Key work includes installing new partitions, doors, flooring and ceilings in various rooms, upgrading telecommunications closets, and modifying spaces to accommodate new uses. The solicitation number for this project is 36C77623B0058, issued by the Department of Veterans Affairs Technology Acquisition Center in Austin, Texas. The estimated period of performance is 11 months from the award date. Pricing will be fixed-price, and the contract has no set-aside provisions.

View the file

Other files

File Type Posted
Abstract of offers - Chillicothe Bid Opening 01172024 signed.pdf PDF
S06 - Amendment 0009 Bid Opening.pdf PDF
S06 - Amendment 0008 Extend due date to 01172024.pdf PDF
S06 - 36C77623B0058 0007.pdf PDF
S06 - Amendment 0007 Att 10 - 14.063_024-EP100 - ELECTRICAL PLAN - BASEMENT FLOOR.pdf PDF
S06 - Amendment 0007 Att 13 - 14.116_E616.31 - PANELBOARD SCHEDULES.pdf PDF
S06 - Amendment 0007 Att 4 - Chiillicothe VA Lead Paint Survey Report.pdf PDF
S06 - Amendment 0007 Att 7 - 000-TS100 - CAMPUS TECHNOLOGY SITE PLAN.pdf PDF
S06 - Amendment 0007 Att 6 - 000-TN500 - TECHNOLOGY DETAILS.pdf PDF
S06 - Amendment 0007 Att 3 - 2023-01 AHERA.pdf PDF
S06 - Amendment 0007 Att 11 - 14.077_031-EP100 - ELECTRICAL PLAN - GROUND FLOOR.pdf PDF
S06 - Amendment 0007 Att 16 - 026-TN100 - BASEMENT PLAN -TECHNOLOGY.pdf PDF
S06 - Amendment 0007 Att 14 - 018-TN209 - TECHNOLOGY ENLARGEMENT.pdf PDF
S06 - Amendment 0007 Att 8 - 13.038_030-MD101 - MECHANICAL DEMOLITION PLAN - FIRST FLOOR.pdf PDF
S06 - Amendment 0007 Att 12 - 14.080_035-EP100 - ELECTRICAL PLAN - BASEMENT.pdf PDF
S06 - Amendment 0007 Att 1 Technical questions Round 2 responses.pdf PDF
S06 - Amendment 0007 Att 2 - Final SWP3.pdf PDF
S06 - Amendment 0007 Att 15 - 018-TN210 - TECHNOLOGY ENLARGEMENT.pdf PDF
S06 - Amendment 0007 Att 5 - 000-TN400 - TECHNOLOGY RISER DIAGRAMS.pdf PDF
S06 - Amendment 0007 Att 9 - 14.062_023-EP101 - ELECTRICAL PLAN - FIRST FLOOR.pdf PDF
Amendment 0006 36C77623B0058.pdf PDF
Amendment 0005 36C77623B0058.pdf PDF
Amendment 0005 - Attachment Addendum 1.zip ZIP file
Amendment 0005 - Attachment - Vendor Questions_Responses final.pdf PDF
Amendment 0004 36C77623B0058.pdf PDF
Amendment 0003 36C77623B0058.docx DOCX document
Att 10 Volume 10 - Technology_Combined.pdf PDF
Att 8 Volume 8 - Electrical_Combined.pdf PDF
Att 6 Volume 6 - Mechanical_Combined.pdf PDF
Att 9 Volume 9 - Electrical_Combined.pdf PDF
Att 13 Volume 13 - Fiber_Combined.pdf PDF
Att 4 Volume 4 - Architectural_Combined.pdf PDF
Att 5 Volume 5 - Fire Suppression_Combined.pdf PDF
Att 14 S04 - Site Visit sign in 10-11-2023.pdf PDF
Att 7 Volume 7 - Mechanical_Combined.pdf PDF
Att 12 Volume 12 - Fiber_Combined.pdf PDF
Att 11 Volume 11 - Technology_Combined.pdf PDF
Att 3 Volume 3 - Architectural_Combined.pdf PDF
Att 2 Volume 2 - Civil_Combined (1).pdf PDF
36C77623B0058 0002.docx DOCX document
Att 1 Volume 1 - General and Civil_Combined.pdf PDF
DBA Wage Rates Construction - Ross Cty.pdf PDF
36C77623B0058 0001.docx DOCX document
Attachment 04 - DBA Wage Determination.pdf PDF
Updated _Specifications_Combined.pdf PDF
Attachment 09 - SOW attach Volume 1 Part 4.pdf PDF
Attachment 04 - Wage Rate Determination - Chillicothe.pdf PDF
Attachment 11 - SOW attach Volume 1 Part 6.pdf PDF
Attachment 19 - SOW attach Volume 3 Part 4.pdf PDF
Attachment 17 - SOW attach Volume 3 Part 2.pdf PDF
Show 40 more

Latest 50 of 65 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROFILE VIEW OF FOC BLDG 25 A

HORIZONTAL SCALE: 1" = 20'

VERTICAL SCALE: 1" = 5'

PROFILE VIEW OF FOC BLDG 25 B

HORIZONTAL SCALE: 1" = 20'

VERTICAL SCALE: 1" = 5'

PROFILE VIEW OF FOC BLDG 21 A

HORIZONTAL SCALE: 1" = 20'

VERTICAL SCALE: 1" = 5'

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

RJJ LKSNo. Revisions: Date:

NOT FOR CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

612-20-101

CHILLICOTHE, OH

CONSTRUCTION

DOCUMENTS - 95%

04/14/2023

CHILLICOTHE

VAMC

DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022

DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022

SCHEMATIC DESIGN - 35% 07/18/2022

DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023

CU211

FIBER P-P BUILDINGS B01

PROFILE VIEW OF FOC BLDG 36 A

VERTICAL SCALE: 1" = 5'

PROFILE VIEW OF FOC BLDG 36 B

HORIZONTAL SCALE: 1" = 20'

VERTICAL SCALE: 1" = 5'

PROFILE VIEW OF FOC BLDG 21 B

HORIZONTAL SCALE: 1" = 20'

VERTICAL SCALE: 1" = 5'

Tripp Street

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

RJJ LKSNo. Revisions: Date:

NOT FOR CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

612-20-101

CHILLICOTHE, OH

CONSTRUCTION

DOCUMENTS - 95%

04/14/2023

CHILLICOTHE

VAMC

DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022

DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022

SCHEMATIC DESIGN - 35% 07/18/2022

DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023

CU212

FIBER P-P BUILDINGS B02

PROFILE VIEW OF FOC BLDG 23 B

VERTICAL SCALE: 1" = 5'

PROFILE VIEW OF FOC BLDG 20 A

HORIZONTAL SCALE: 1" = 20'

VERTICAL SCALE: 1" = 5'

Tripp Street Tripp Street

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

RJJ LKSNo. Revisions: Date:

NOT FOR CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

612-20-101

CHILLICOTHE, OH

CONSTRUCTION

DOCUMENTS - 95%

04/14/2023

CHILLICOTHE

VAMC

DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022

DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022

SCHEMATIC DESIGN - 35% 07/18/2022

DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023

CU213

FIBER P-P BUILDINGS B03

PROFILE VIEW OF FOC BLDG 20 B

VERTICAL SCALE: 1" = 5'

PROFILE VIEW OF FOC BLDG 259 A

HORIZONTAL SCALE: 1" = 20'

VERTICAL SCALE: 1" = 5'

Tripp Street

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

RJJ LKSNo. Revisions: Date:

NOT FOR CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

612-20-101

CHILLICOTHE, OH

CONSTRUCTION

DOCUMENTS - 95%

04/14/2023

CHILLICOTHE

VAMC

DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022

DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022

SCHEMATIC DESIGN - 35% 07/18/2022

DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023

CU214

FIBER P-P BUILDINGS B04

PROFILE VIEW OF FOC BLDG 261 A

VERTICAL SCALE: 1" = 5'

PROFILE VIEW OF FOC BLDG 261 B

HORIZONTAL SCALE: 1" = 20'

VERTICAL SCALE: 1" = 5'

PROFILE VIEW OF FOC BLDG 259 B

HORIZONTAL SCALE: 1" = 20'

VERTICAL SCALE: 1" = 5'

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

RJJ LKSNo. Revisions: Date:

NOT FOR CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

612-20-101

CHILLICOTHE, OH

CONSTRUCTION

DOCUMENTS - 95%

04/14/2023

CHILLICOTHE

VAMC

DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022

DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022

SCHEMATIC DESIGN - 35% 07/18/2022

DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023

CU215

FIBER P-P BUILDINGS B05

PROFILE VIEW OF FOC BLDG 60 A

VERTICAL SCALE: 1" = 5'

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

RJJ LKSNo. Revisions: Date:

NOT FOR CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

612-20-101

CHILLICOTHE, OH

CONSTRUCTION

DOCUMENTS - 95%

04/14/2023

CHILLICOTHE

VAMC

DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022

DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022

SCHEMATIC DESIGN - 35% 07/18/2022

DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023

CU216

FIBER P-P BUILDINGS B06

PROFILE VIEW OF FOC BLDG 60 A

VERTICAL SCALE: 1" = 5'

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

RJJ LKSNo. Revisions: Date:

NOT FOR CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

612-20-101

CHILLICOTHE, OH

CONSTRUCTION

DOCUMENTS - 95%

04/14/2023

CHILLICOTHE

VAMC

DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022

DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022

SCHEMATIC DESIGN - 35% 07/18/2022

DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023

CU217

FIBER P-P BUILDINGS B07

PROFILE VIEW OF FOC BLDG 60 B

VERTICAL SCALE: 1" = 5'

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

RJJ LKSNo. Revisions: Date:

NOT FOR CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

612-20-101

CHILLICOTHE, OH

CONSTRUCTION

DOCUMENTS - 95%

04/14/2023

CHILLICOTHE

VAMC

DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022

DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022

SCHEMATIC DESIGN - 35% 07/18/2022

DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023

CU218

FIBER P-P BUILDINGS B08

PROFILE VIEW OF FOC BLDG 60 B

VERTICAL SCALE: 1" = 5'

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

RJJ LKSNo. Revisions: Date:

NOT FOR CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

612-20-101

CHILLICOTHE, OH

CONSTRUCTION

DOCUMENTS - 95%

04/14/2023

CHILLICOTHE

VAMC

DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022

DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022

SCHEMATIC DESIGN - 35% 07/18/2022

DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023

CU219

FIBER P-P BUILDINGS B09

PROFILE VIEW OF FOC BLDG 247 B

VERTICAL SCALE: 1" = 5'

PROFILE VIEW OF FOC BLDG 247 A

HORIZONTAL SCALE: 1" = 20'

VERTICAL SCALE: 1" = 5'

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

RJJ LKSNo. Revisions: Date:

NOT FOR CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

612-20-101

CHILLICOTHE, OH

CONSTRUCTION

DOCUMENTS - 95%

04/14/2023

CHILLICOTHE

VAMC

DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022

DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022

SCHEMATIC DESIGN - 35% 07/18/2022

DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023

CU220

FIBER P-P BUILDINGS B10

PROFILE VIEW OF FOC BLDG 31 A

VERTICAL SCALE: 1" = 5'

PROFILE VIEW OF FOC BLDG 31 B

HORIZONTAL SCALE: 1" = 20'

VERTICAL SCALE: 1" = 5'

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

RJJ LKSNo. Revisions: Date:

NOT FOR CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

612-20-101

CHILLICOTHE, OH

CONSTRUCTION

DOCUMENTS - 95%

04/14/2023

CHILLICOTHE

VAMC

DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022

DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022

SCHEMATIC DESIGN - 35% 07/18/2022

DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023

CU221

FIBER P-P BUILDINGS B11

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

RJJ LKSNo. Revisions: Date:

NOT FOR CONSTRUCTION

EHRM INFRASTRUCTURE

UPGRADES

612-20-101

CHILLICOTHE, OH

CONSTRUCTION

DOCUMENTS - 95%

04/14/2023

CHILLICOTHE

VAMC

DESIGN DEVELOPMENT - 65% SUBMITTAL 10/14/2022

DESIGN DEVELOPMENT - 65% SUBMITTAL REV 1 12/16/2022

SCHEMATIC DESIGN - 35% 07/18/2022

DESIGN DEVELOPMENT - 95% SUBMITTAL 03/17/2023

CONCRETE HEADER3

MOUNTABLE CONCRETE CURB AND GUTTER4

CONCRETE CURB AND TERMINAL SECTION2

TYPE 2 UTILITY TRENCH PATCH5 TYPE 3 UTILITY TRENCH PATCH6

GENERAL NOTES

PCC SIDEWALK DETAIL1

PLACE CONCRETE BLOCK

OR OTHER DEVICE TO

PREVENT TUBE FROM

PLUGGING INTAKE

OVERLAP TUBE 1' AND SECURE

WITH WIRE OR WIRE TIES

UNDISTRIBUTED

GROUND

FILTER CLOTH

16" MIN. HEIGHT

OF FILTER CLOTH

0"

M

IN

0"

M

IN

8" M

IN EMBED FILTER CLOTH MIN.

10" INTO GROUND

48" MIN. FENCE POST

ROLL WITH TRACTOR

TIRE 1-4 TIMES

STATIC SLICE INSTALLATION

PERIMETER SEDIMENT CONTROL NOTES:

1. FENCE POST TO BE STEEL "T" OR "U" TYPE OR 2" HARDWOOD. FENCE POSTS

ARE TO BE DRIVEN INTO GROUND 18" MIN. AT 10' MAXIMUM SPACING.

2. FILTER CLOTH TO BE FILTER X, MIRAFI 100X, STABILINKA T140N. CLOTH TO BE

FASTENED SECURELY TO FENCE POSTS. WHEN TWO SECTIONS OF FILTER

CLOTH ADJOIN EACH OTHER THEY SHALL BE OVERLAPPED BY 6" AND FOLDED.

3. MAINTENANCE SHALL BE PERFORMED AS NEEDED AND MATERIAL REMOVED

WHEN "BULGES" DEVELOP IN THE SILT FENCE.

PERIMETER SEDIMENT CONTROL DETAIL

FILTER TUBES USED FOR INLET PROTECTION8

CK101

CIVIL DETAILS

UP UP

DN

ZONE 1

ZONE 3ZONE 2

ZONE 5ZONE 4

001-AE100.1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:5

:4

P

M

001-AE100

OVERALL BASMENT FLOOR PLAN

03/17/2023 PQ JF

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 001

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N

1" = 10'-0"

BUILDING 1 - BASEMENT FLOOR PLAN

001-AE100.1

Training Room

BB103

Game Room

BC100A

Storage

BB102

TELECOMM. ROOM

BB105

Cio Equipment Storage

BB101

Stair

S1-0

Corridor

CB6

Corridor

CB5

Engineering Room

BB104

Mechanical

BB106

Tele Clos

BB104A

Toilet

BB107

Corridor

CB4

Stair

S2-0Storage

BB100

Corridor

CB1

Storage

BB101A

2 - 5

TELECOMM. ROOM

BB105

BB105

TELECOMM. ROOM

BB105

TELECOMM. ROOM

BB105

BB105

TELECOMM. ROOM

BB105

A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.

B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.

G E N E R A L D E M O L I T I O N N O T E S

G E N E R A L C O N S T R U C T I O N N O T E S

A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.

B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.

C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED

OTHERWISE.

D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER

MANUFACTURER'S WRITTEN INSTRUCTIONS.

E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE

ACCORDINGLY.

F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.

G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.

H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO

MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.

I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.

J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED

OTHERWISE.

K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE

STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.

L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A

PARTITION BRACING ELEMENT.

M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.

N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER

REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.

O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION

P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.

S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED

WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:5

:0

P

M

001-AE100.1

BASEMENT FLOOR PLAN - ZONE 1

03/17/2023 PQ JF

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 001

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

1/8" = 1'-0"

BASEMENT FLOOR PLAN - ZONE 1

1/4" = 1'-0"

DEMO - TR LOCATION FLOOR PLAN

1/4" = 1'-0"

DEMO - TR LOCATION RCP

1/4" = 1'-0"

NEW WORK - TR LOCATION FLOOR PLAN

1/4" = 1'-0"

NEW WORK - TR LOCATION RCP

D R A W I N G N O T E S :

1 REMOVE EXISTING DOOR FRAME AND DOOR LEAF; TURN DOOR LEAF OVER TO VA TO ADD TO EXISTING STOCK.

2 REMOVE EXISTING FLOORING FINISH AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR

INSTALLATION OF ELECTRIC DISSIPATING FLOORING DURING CONSTRUCTION.

3 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND

CONDUIT. PAINT WHITE ALL BUT FIRE RATING LABEL.

4 EXISTING MOUNTED PLYWOOD TO REMAIN, TYPICAL.

5 INSTALL ELECTRICAL DISSIPATING FLOOR PAINT - SEE HATCHED AREA

6 WINDOW SECURITY BARS - INSTALLED ON INTERIOR OF WINDOW OPENING

7 REMOVE WALL BASE ALONG THIS WALL - LEADER ARROW POINTS TO WALL SURFACE

8 INSTALL WALL BASE ALONG WALL

9 MOUNT AND PROVIDE NEW ABC FIRE EXTINGUISHER

10 REMOVE ALL PAINT AND DEBRIS FROM WALL. AREA IDENTIFIED BY DASHED LINE.

11 PAINT WALLS - REFER TO FINISH SCHEDULE

12 NO CEILING IN THIS AREA

DN DNDN

ZONE 1

ZONE 3ZONE 2

ZONE 5ZONE 4

001-AE101.1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:5

:1

P

M

001-AE101

OVERALL FIRST FLOOR PLAN

03/17/2023 PQ JF

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 001

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

1" = 10'-0"

BUILDING 1 - FIRST FLOOR PLAN

UP

Toilet

Voucher Examiner & Employee Travel

Conference Room

Contract Specialist

Contract Spec Intern

Supply Tech

Chief Acquisitions/ Contracting

Contract Liason

Contract Specialist

Contract Specialists

Admin Support Assist

Chief Logistics

Chief Inventory Supply Support

Inventory Management Spec

Item Manager

Item Manager

Item Manager

Xerox/supplies

Toilet

Files Storage

TR

Corridor

1C002

Corridor

1C006

Stair

S1-1

001-AE101.2

22 - 5

A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.

B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.

G E N E R A L D E M O L I T I O N N O T E S

G E N E R A L C O N S T R U C T I O N N O T E S

A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.

B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.

C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED

OTHERWISE.

D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER

MANUFACTURER'S WRITTEN INSTRUCTIONS.

E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE

ACCORDINGLY.

F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.

G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.

H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO

MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.

I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.

J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED

OTHERWISE.

K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE

STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.

L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A

PARTITION BRACING ELEMENT.

M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.

N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER

REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.

O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION

P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.

S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED

WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.

Files Storage

TR

Files Storage

TR

9 10

Files Storage

98 SF

TR

TR

Files Storage

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:5

:3

P

M

001-AE101.2

FIRST FLOOR PLAN - ZONE 2

03/17/2023 Checker Author

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95%CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

1/8" = 1'-0"

FIRST FLOOR PLAN - ZONE 1

D R A W I N G N O T E S :

1 REMOVE WALL

2 NO CEILING IN THIS AREA

3 MOUNT AND PROVIDE NEW ABC FIRE EXTINGUISHER

4 INSTALL ELECTRICAL DISSIPATING FLOOR PAINT - SEE HATCHED AREA

5 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND

CONDUIT. PAINT WHITE ALL BUT FIRE RATING LABEL.

6 WINDOW SECURITY BARS - INSTALLED ON INTERIOR OF WINDOW OPENING

7 REMOVE CEILING SYSTEMS AND SUPPORTS

8 REMOVE CEILING GRID AND ACOUSTICAL TILES. LEAVE CEILING GRID SUPPORTS FOR INSTALLATION OF NEW GRID AND

TILES.

9 PAINT WALLS - REFER TO FINISH SCHEDULE

10 INSTALL WALL BASE, MATCH EXISTING BASE.

1/4" = 1'-0"

B01 - FIRST FLOOR PLAN - ZONE 1

1/4" = 1'-0"

B01 - FIRST FLOOR PLAN - ZONE 1

1/4" = 1'-0"

B01 - FIRST FLOOR - ZONE 2 - TR - NEW RCP

1/4" = 1'-0"

B01 - FIRST FLOOR - ZONE 2 - TR - DEMO RCP

DN DNDN

001-AE101.1

Risk Manager

Performance Measure Coordinator

Patient Safety

External Review Manager

Contracting Liason Office

Toilet

Filing Supplies

Utilization Nurse

HAC

Performance Measure Coordinator

Program Support Assistant

Systems Design Coordinator

HAC

Copy Room

Break Room

TR

Quality Improvement Facilitator

Quality Manager

QI Program Asst

Waiting

1L001

Corridor

1C002

Waiting

1L002

Corridor

1C007

Stair

S2-1

Stair

S1-1

2 - 5

Eeo Manage

TR

1L002

Eeo Manage

TR

A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.

B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.

G E N E R A L D E M O L I T I O N N O T E S

G E N E R A L C O N S T R U C T I O N N O T E S

A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.

B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.

C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED

OTHERWISE.

D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER

MANUFACTURER'S WRITTEN INSTRUCTIONS.

E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE

ACCORDINGLY.

F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.

G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.

H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO

MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.

I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.

J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED

OTHERWISE.

K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE

STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.

L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A

PARTITION BRACING ELEMENT.

M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.

N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER

REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.

O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION

P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.

S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED

WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:5

:2

P

M

001-AE101.1

FIRST FLOOR PLAN - ZONE 1

03/17/2023 PQ JF

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 001

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

1/8" = 1'-0"

FIRST FLOOR PLAN - ZONE 1

1/4" = 1'-0"

ROOM 179 - DEMOLITION FLOOR PLAN

1/4" = 1'-0"

ROOM 179 - FLOOR PLAN

D R A W I N G N O T E S :

1 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND

CONDUIT. PAINT WHITE ALL BUT FIRE RATING LABEL.

2 REMOVE EXISTING FLOORING FINISH AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR

INSTALLATION OF ELECTRIC DISSIPATING FLOORING DURING CONSTRUCTION.

3 REMOVE CEILING SYSTEMS AND SUPPORTS

4 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND

CONDUIT. PAINT WHITE ALL BUT FIRE RATING LABEL.

5 INSTALL ELECTRICAL DISSIPATING FLOOR PAINT - SEE HATCHED AREA

6 WINDOW SECURITY BARS - INSTALLED ON INTERIOR OF WINDOW OPENING

7 NO CEILING IN THIS AREA

8 REMOVED AND REPLACE FRAME AND LOCKSET AS REQUIRED FOR CARD READER. REUSE REMAINING HARDWARE

9 MOUNT AND PROVIDE NEW ABC FIRE EXTINGUISHER

10 REMOVE PACKAGED THERMAL UNIT

1/4" = 1'-0"

B01 - FIRST FLOOR - ZONE 1 - TR - DEMO RCP

1/4" = 1'-0"

B01 - FIRST FLOOR - ZONE 1 - TR - NEW RCP

DN

UP

D

EM

D

D

EM

D

EM

D

EM

D

D

D

EM

EM

D

D

D

EM

E M

D

D

E M

D

ZONE 1

ZONE 3ZONE 2

ZONE 5ZONE 4

001-AE102.1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:5

:4

P

M

001-AE102

OVERALL SECOND FLOOR PLAN

03/17/2023 PQ JF

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 001

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N

1" = 10'-0"

B01 - SECOND FLOOR - OVERALL

190 SF

Toilet

Toilet

9 SF

Elect. Room

196 SF

Piv Room

197 SF

Regional Counsel Conf

Regional Counsel Library

Hr Assistants

Copy/mail Room

Hrm Office

Intern Office

Hrm Office

Resource Room

Hrm Specalists

Vet Pro

Hrm Office

Hrm Office

Hrm Office

Tele Clos

Employee Resources

Regional Counsel Office

224A

Corridor

2C5

Regional Counsel Office

224B

Tele Clos

Stair

S1-2

Corridor

2C003

302 SF

Corridor

2C002

155 SF

Corridor

2C3

HMR ASSISTANT

238 001-AE102.2

22 - 5

A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.

B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.

G E N E R A L D E M O L I T I O N N O T E S

G E N E R A L C O N S T R U C T I O N N O T E S

A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.

B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.

C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED

OTHERWISE.

D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER

MANUFACTURER'S WRITTEN INSTRUCTIONS.

E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE

ACCORDINGLY.

F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.

G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.

H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO

MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.

I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.

J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED

OTHERWISE.

K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE

STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.

L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A

PARTITION BRACING ELEMENT.

M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.

N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER

REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.

O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION

P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.

S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED

WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.

Tele Clos

HMR ASSISTANT

REMOVE FLOORING BOUNDARY

Tele Clos

HMR ASSISTANT

5 6

7 8

HMR ASSISTANT

Tele Clos

HMR ASSISTANT

Tele Clos

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:5

:1

P

M

001-AE102.2

SECOND FLOOR PLAN - ZONE 2

03/17/2023 Checker Author

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95%CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N

1/8" = 1'-0"

B01 - SECOND FLOOR PLAN - ZONE 2

D R A W I N G N O T E S :

1 REMOVE EXISTING FLOORING FINISH AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR

INSTALLATION OF ELECTRIC DISSIPATING FLOORING DURING CONSTRUCTION.

2 REMOVE WALL

3 NEW WALL - REFER TO GI001 FOR WALL TYPE DETAIL - 1 HR FIRE RATING

4 INSTALL ELECTRICAL DISSIPATING FLOOR PAINT - SEE HATCHED AREA

5 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND

CONDUIT. PAINT WHITE ALL BUT FIRE RATING LABEL.

6 WINDOW SECURITY BARS - INSTALLED ON INTERIOR OF WINDOW OPENING

7 PAINT WALLS - REFER TO FINISH SCHEDULE

8 INSTALL WALL BASE ALONG WALL

1/4" = 1'-0"

B01 - SECOND FLOOR PLAN - ZONE 2 - TR - DEMO PLAN

1/4" = 1'-0"

B01 - SECOND FLOOR PLAN - ZONE 2 - TR - NEW PLAN

1/4" = 1'-0"

B01 - SECOND FLOOR PLAN - ZONE 2 - TR - DEMO RCP

1/4" = 1'-0"

B01 - SECOND FLOOR PLAN - ZONE 2 - TR - NEW WORK RCP

DN

UP

001-AE102.1

22 - 5

Health Systems Spec Pcs

Emergency Preparedness Coordinator

Patient Business Intern

Assistant Patient Business Manager

Customer Service Coordinator

Toilet

Dss Liason

Interior Designer

Conference/Training

Facility Telehealth Coordinator

HAC

Break Room

Toilet

Training Room

Training Room

Patient Business Service Manager

245A

Heart Code Room

Stair

S1-2

Stair

S2-2

Corridor

2C002

Corridor

2C001 Corridor

2C006

Corridor

2C005

TR

284B

TR

284B

10' - 5"

R E

M O

V E

F

LO

O

R

IN

G B

O U

N D

A R

Y

TRAINING ROOM

TRAINING ROOM

10' - 5"

TR

284B

284B

TRAINING ROOM

A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.

B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.

G E N E R A L D E M O L I T I O N N O T E S

G E N E R A L C O N S T R U C T I O N N O T E S

A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.

B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.

C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED

OTHERWISE.

D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER

MANUFACTURER'S WRITTEN INSTRUCTIONS.

E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE

ACCORDINGLY.

F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.

G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.

H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO

MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.

I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.

J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED

OTHERWISE.

K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE

STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.

L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A

PARTITION BRACING ELEMENT.

M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.

N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER

REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.

O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION

P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.

S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED

WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:5

:0

P

M

001-AE102.1

SECOND FLOOR PLAN - ZONE 1

03/17/2023 PQ JF

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 001

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N

1/8" = 1'-0"

B01 - SECOND FLOOR PLAN - ZONE 1

1/4" = 1'-0"

B01 - SECOND FLOOR PLAN - ZONE 1 - TR - NEW WORK RCP

1/4" = 1'-0"

B01 - SECOND FLOOR PLAN - ZONE 1 - TR - DEMO PLAN

1/4" = 1'-0"

B01 - SECOND FLOOR PLAN - ZONE 1 - TR - NEW WORK PLAN

1/4" = 1'-0"

B01 - SECOND FLOOR PLAN - ZONE 1 - TR - DEMO RCP

D R A W I N G N O T E S :

1 REMOVE EXISTING FLOORING FINISH AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR

INSTALLATION OF ELECTRIC DISSIPATING FLOORING DURING CONSTRUCTION.

2 WINDOW SECURITY BARS - INSTALLED ON INTERIOR OF WINDOW OPENING

3 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND

CONDUIT. PAINT WHITE ALL BUT FIRE RATING LABEL.

4 INSTALL ELECTRICAL DISSIPATING FLOOR PAINT - SEE HATCHED AREA

5 REMOVE EXISTING DOOR FRAME AND DOOR LEAF; TURN DOOR LEAF OVER TO VA TO ADD TO EXISTING STOCK.

6 REMOVE CEILING SYSTEMS AND SUPPORTS WHERE FUTURE TR IS. LEAVE CEILING SUPPORTS IN ADJACENT SPACE THAT

WILL NEED TO HAVE CEILING INSTALLED AND TIED INTO EXISTING CEILING GRID.

7 NO CEILING IN THIS AREA

8 INSTALL NEW CEILING COMPONENTS TO TIE EXISTING CEILING SYSTEM TO NEW WALL - MATCH EXISTING GRID

COMPONENTS AND ACOUSTICAL CEILING TILES

9 NEW WALL - REFER TO GI001 FOR WALL TYPE DETAIL - 1 HR FIRE RATING

10 INSTALL WALL BASE, MATCH EXISTING BASE.

ZONE 1

ZONE 2

ZONE 4 ZONE 5

ZONE 3

003-AE101.1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:5

:1

P

M

003-AE101

OVERALL FIRST FLOOR PLAN

03/17/2023 PQ JF

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 003

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N

1" = 10'-0"

B03 - FIRST FLOOR PLAN - OVERALL

003-AE101.1

Supply

106C

HAC

106E

Toilet

106F

Toilet

106G

Corridor

C1-3

Corridor

C1-1

Vet Rep

107A

Day Treatment Office

Program Assistant

Forms Storage

110A

Elect. Room

111A

Toilet

TR

Office

Incentive Therapy

Vestibule

Office

100G

Office

100E

Office

100F

Stair

S2-1

Stair

S1-1

Elect. Room

100A

Office

100H

Office

100D

Supply

100B

Office

100C

Corridor

Existing Dark Room

106A

Waiting

Corridor

106B

Veteran's Industries Marketing

Corridor

C1-2

2 - 5

TR

TR

TR

TR

A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.

B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.

G E N E R A L D E M O L I T I O N N O T E S

G E N E R A L C O N S T R U C T I O N N O T E S

A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.

B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.

C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED

OTHERWISE.

D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER

MANUFACTURER'S WRITTEN INSTRUCTIONS.

E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE

ACCORDINGLY.

F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.

G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.

H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO

MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.

I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.

J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED

OTHERWISE.

K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE

STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.

L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A

PARTITION BRACING ELEMENT.

M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.

N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER

REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.

O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION

P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.

S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED

WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:5

:2

P

M

003-AE101.1

FIRST FLOOR PLAN - ZONE 1

03/17/2023 PQ JF

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 003

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N

1/8" = 1'-0"

B03 - FIRST FLOOR PLAN - ZONE 1

1/4" = 1'-0"

B03 - FIRST FLOOR PLAN - ZONE 1 - TR - DEMO PLAN

1/4" = 1'-0"

B03 - FIRST FLOOR PLAN - ZONE 1 - TR - NEW WORK PLAN

1/4" = 1'-0"

B03 - FIRST FLOOR PLAN - ZONE 1 - TR - DEMO RCP

1/4" = 1'-0"

B03 - FIRST FLOOR PLAN - ZONE 1 - TR - DEMO RCP

D R A W I N G N O T E S :

1 REMOVE EXISTING FLOORING FINISH AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR

INSTALLATION OF ELECTRIC DISSIPATING FLOORING DURING CONSTRUCTION.

2 REMOVE CEILING SYSTEMS AND SUPPORTS

3 INSTALL ELECTRICAL DISSIPATING FLOOR PAINT - SEE HATCHED AREA

4 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND

CONDUIT. PAINT WHITE ALL BUT FIRE RATING LABEL.

5 WINDOW SECURITY BARS - INSTALLED ON INTERIOR OF WINDOW OPENING

6 MOUNT AND PROVIDE NEW ABC FIRE EXTINGUISHER

7 NO CEILING IN THIS AREA

Uniform/PAP Work Room

108K2

PAP Storage

108K3

Toilet

108K4

PAP Storage

108K1

Uniform Drop-off

108K

Toilet

108J

Vestibule

108V2

Corridor

108L

Serving Line/Dining Area

Chief Dietetics

106A

Vestibule

108V1

Dietetics Secretary

106B

Conference Room

Mechanical

106H

Entry

106I

Delivery/Entry

105B

Cart Room

Office

106E

Office

106F

Office

106G Office

106D

HAC

105A

Elect. Room

107A

Toilet

106C

Tele Clos

106K

Closet

106J

Kitchen

104A

Kitchen

Supervisor's Office

Stair 2

S-2-1

Office

Toilet

Freezer

Corridor

Entry Corridor

HAC

115A

Mechanical

109A

Freezer

Dishwashing

109Toilet

Toilet

Vestibule

108V4

Tray Line Assembly

108C

Corridor

109D

HAC

109B Dishwashing

Dietician Office

108F

Toilet

108A

Toilet

108B

TR

108D

Soiled Utility

108G Clean Linen

108H

HAC

108E

Ingredient Control

Refrigerator

118BFreezer

118C

Entry

Stair 1

S-1-1

Toilet

120B

Closet

120C

Office

120A

Freezer

118E

Refrigerator

118D

Vestibule

108V3

Office

120D

Mechanical/Generator Room

109CDock

104B

Closet

105C

Corridor

007-AE101

22 - 5

108G

Soiled Utility

TELE. CLOSET

108D

108D

TR

108D

108G

Soiled Utility

TELE. CLOSET

108D

TR

108D

A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.

B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.

G E N E R A L D E M O L I T I O N N O T E S G E N E R A L C O N S T R U C T I O N N O T E S

A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.

B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.

C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED

OTHERWISE.

D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER

MANUFACTURER'S WRITTEN INSTRUCTIONS.

E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE

ACCORDINGLY.

F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.

G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.

H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO

MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.

I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.

J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED

OTHERWISE.

K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE

STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.

L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A

PARTITION BRACING ELEMENT.

M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.

N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER

REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.

O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION.

P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.

S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED

WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:5

:4

P

M

007-AE101

OVERALL FIRST FLOOR PLAN

03/17/2023 PQ JF

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 007

CHILLICOTHE

VAMC

Approved: Veteran's Affairs Medical Center

No. Revisions: Date:

CONSTRUCTION DOCUMENTS - 95% 04/14/2023

N

1" = 10'-0"

B07 - FIRST FLOOR PLAN - OVERALL

1/4" = 1'-0"

B07 - FIRST FLOOR PLAN - TR - DEMO PLAN

1/4" = 1'-0"

B07 - FIRST FLOOR PLAN - TR - NEW WORK PLAN

1/4" = 1'-0"

B07 - FIRST FLOOR PLAN - TR - DEMO RCP

1/4" = 1'-0"

B07 - FIRST FLOOR PLAN - TR - NEW WORK RCP

D R A W I N G N O T E S :

1 REMOVE EXISTING FLOORING FINISH AND MASTIC MATERIAL FROM FLOOR. CLEAN AND PREPARE FLOOR FOR

INSTALLATION OF ELECTRIC DISSIPATING FLOORING DURING CONSTRUCTION.

2 REMOVE WALL

3 REMOVE CEILING SYSTEMS AND SUPPORTS

4 EXISTING MOUNTED PLYWOOD TO REMAIN, TYPICAL.

5 INSTALL ELECTRICAL DISSIPATING FLOOR PAINT - SEE HATCHED AREA

6 INSTALL 3/4" FIRE-RETARDANT TREATED PLYWOOD - 4' X 8' SHEETS ALIGN WITH EXISTING - CUT AROUND OUTLETS AND

CONDUIT. PAINT WHITE ALL BUT FIRE RATING LABEL.

7 REMOVE WALL BASE ALONG THIS WALL - LEADER ARROW POINTS TO WALL SURFACE

8 MOUNT AND PROVIDE NEW ABC FIRE EXTINGUISHER

D R A W I N G N O T E S :

DN DN

UP

DN

Lobby

Auditorium

Elevator Lobby

Volunteer Work Room

110American Legion Aux

Activities Aide

Activities Aide

Corridor

4M

Closet

Stair

S2-1

Storage

105A

Storage

105B

Lobby

Chair Storage

Vestibule

101A

Lounge

HAC

Stair

S1 Toilet

Toilet

103A

HAC

Corridor

101B

009-AE101

22 - 5

Volunteer Work Room

CLOSET

/8

9' - 10 7/8"

DEMOLITION BOUNDARY

Volunteer Work Room

TR

9' - 6"

CLOSET

Volunteer Work Room

TR

A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRIAL ROOMS ARE APPROXIMATELY 12' TALL.

B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.

G E N E R A L D E M O L I T I O N N O T E S G E N E R A L C O N S T R U C T I O N N O T E S

A. ALL PROPOSED PARTITIONS ARE ARE TYPE 1 - REFER TO WALL TYPE DETAIL ON SHEET GI001.

B. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.

C. ALL DIMENSIONS ARE TO COLUMN CENTERLINES OR FINISHED ELEVATION OF WALLS OR SURFACES UNLESS NOTED

OTHERWISE.

D. CONTRACTOR TO PROVIDE ALL RELATED FASTENERS, TRIM AND ACCESSORIES FOR INSTALL PRODUCTS PER

MANUFACTURER'S WRITTEN INSTRUCTIONS.

E. REFER TO DEMOLITION DRAWINGS, IF ANY, FOR WORK REQUIRED IN ADVANCE OF CONSTRUCTION AND COORDINATE

ACCORDINGLY.

F. ALL DOOR FRAMES ARE TO BE INSTALLED 4" AWAY OF ADJACENT PERPENDICULAR WALLS UNLESS NOTED OTHERWISE.

G. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL M.E.P. SPECIFIC INFORMATION.

H. EXISTING CONSTRUCTION TO REMAIN. EXTERIOR WALLS AND COLUMN ENCLOSURES SHALL BE PATCHED AS REQUIRED TO

MATCH ADJACENT NEW CONSTRUCTION AND RECEIVE NEW FINISHES.

I. COLD-FORMED STEEL (CFS) FRAMING SUPPLIER SHALL PROVIDE ENGINEERED DRAWINGS.

J. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED

OTHERWISE.

K. WHERE PARTITIONS OF DIFFERENT THICKNESS MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE

STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE.

L. CFS FRAMING STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A

PARTITION BRACING ELEMENT.

M. PROVIDE DOUBLE 0.0312" CFS FRAMING STUDS AT JAMBS OF DOOR AND FIXED GLASS FRAMES, AT OPEN PARTITION ENDS, AND WHERE PARTITION IS TO RECEIVE WALL MOUNTED SHELVES, CASEWORK, PLUMBING FIXTURES, ETC.

N. PROVIDE ADDITIONAL BRACING AS REQUIRED AT ALL CFS FRAMING STUD INSTALLATIONS EXCEEDING STUD MANUFACTURER

REQUIREMENTS FOR MAXIMUM ALLOWED HEIGHT AND DEFLECTION.

O. REFER TO CEILING PLAN AND FINISH LEGEND FOR CEILING FINISH INFORMATION.

P. REFER TO MECHANICAL DRAWINGS FOR QUANTITY AND TYPE OF DIFFUSERS, RETURN AIR GRILLES, AND EXHAUST GRILLES.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

Q. REFER TO ELECTRICAL DRAWINGS FOR QUANTITY AND TYPES OF LIGHTS, SPEAKERS, DETECTORS, POWER OUTLETS, ETC.

SCRIBE CEILING MATERIALS CAREFULLY FOR A TIGHT FIT.

R. SEAL ALL PENITRATIONS. SEAL PENTRATIONS IN RATED ASSEMBLIES WITH SEALANT TO MATCH RATING OF ASSMEBLY.

S. FILL ALL OPENINGS IN WALLS, FLOOR, CEILINGS AS A RESULT OF DEMOLITION. MAINTAIN ASSEMBLY RATING IN RATED

WALLS, FLOORS AND CEILIGNS AS INDICATED ON PLANS.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

NOT FOR CONSTRUCTION

A u to d e s k D o c s /C h ill ic o th e V

A

E H

R M

/F F

E

C h ill ic o th e

E H

R M

C a m p u s rv t

/1

/2

:0

:0

P

M

009-AE101

OVERALL FIRST FLOOR PLAN

03/17/2023 PQ JF

EHRM INFRASTRUCTURE

UPGRADES

538-21-701

CHILLICOTHE, OHIO

CONSTRUCTION

DOCUMENTS - 95% 009

CHILLICOTH…