618-21-700.MEHRM.FINAL.B70.20220506Part-5.pdf

PDF 16 MB Posted

Attached to
EHRM Infrastructure Upgrades Construction Design-Bid Build Project at the Minneapolis VA Medical Center (VAMC)
Solicitation number
36C77622R0045
Issued by

About this file

This document provides details on a federal contract opportunity for construction design and infrastructure upgrades at the Minneapolis VA Medical Center. The project scope involves construction and commissioning of infrastructure needed for the VA's Electronic Health Record Modernization initiative, including building a new server room. Work will take place across multiple departments and is expected to be completed within 450 calendar days of the notice to proceed. The total magnitude of construction is estimated between $20-50 million. The solicitation will be issued as a request for proposal evaluated according to FAR Parts 15, 19, and 36 and will be set aside specifically for Service-Disabled Veteran-Owned Small Businesses. All questions must be submitted in writing by the deadline to the identified point of contact.

View the file

Other files

File Type Posted
Technical Question Tracking Sheet Infra Upgrades FINAL.pdf PDF
36C77622R0045 0009.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-11.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-1.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-7.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-2.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-6.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-4.pdf PDF
618-21-700.ADD-001.Summary.Log.20220707.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-9.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-5.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-10.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-3.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-8.pdf PDF
36C77622R0045 0008.docx DOCX document
Technical Question Tracking Sheet - Infra Upgrades - FINAL.pdf PDF
36C77622R0045 0007.pdf PDF
36C77622R0045 0006.docx DOCX document
Technical Question Tracking Sheet - Infra Upgrades - Minneapolis.docx DOCX document
36C77622R0045 0005.docx DOCX document
36C77622R0045 0004.docx DOCX document
Technical Question Tracking Sheet - Infra Upgrades.docx DOCX document
36C77622R0045 0003.pdf PDF
Site Visit Sign In sheet.pdf PDF
36C77622R0045 0002.pdf PDF
36C77622R0045 0001.pdf PDF
36C77622R0045 - Update 5.23.22.docx DOCX document
618-21-700.MEHRM.FINAL.B70.20220506Part-7.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-11.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-33-36.zip ZIP file
618-21-700.MEHRM.FINAL.B76.20220506-REDUCED.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-48-52.zip ZIP file
36C77622R0045.docx DOCX document
618-21-700.MEHRM.FINAL.B70.20220506Part-21.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-25-28.zip ZIP file
618-21-700.MEHRM.FINAL.B70.20220506Part-4.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-23.pdf PDF
618-21-700.MEHRM.FINAL.B75.20220506-REDUCED.pdf PDF
618-21-700.MEHRM.FINAL_SPECIFICATIONS.20220506Part-2.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-45-47.zip ZIP file
618-21-700.MEHRM.FINAL.B70.20220506Part-6.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-13.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-20.pdf PDF
618-21-700.MEHRM.FINAL.B73.20220506-REDUCED.pdf PDF
618-21-700.MEHRM.FINAL.B49.20220506-REDUCED.pdf PDF
01 00 00 Appendix A - Bid Form Template.xlsx XLSX spreadsheet
618-21-700.MEHRM.FINAL.SITE.20220506-REDUCED.pdf PDF
618-21-700.MEHRM.FINAL.B222.20220506-REDUCED.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-12.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-16-17.zip ZIP file
Show 40 more

Latest 50 of 80 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET SYMBOL LEGEND

KEYNOTES

GENERAL NOTES

EXISTING CONSTRUCTION TO REMAIN

EXISTING CONSTRUCTION TO BE DEMOLISHED

NEW CONSTRUCTION, WITH PARTITION TYPE

A

A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT

REQUIREMENTS AND PROJECT LOCATION DRAWINGS.

B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES

INFORMATION.

C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL

SYSTEMS INFORMATION.

D. NEW IT CLOSETS SHALL BE SMOKE RATED AND COMPLY WITH THE

LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS

STANDARDS.

E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.

F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.

G. SEE TYPICAL CEILING DETAILS ON SHEET A-531

PARTITION RATING GRAPHICS:

2 HR FIRE SHAFT

1 HR SMOKE BARRIER

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION:

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND

SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.

1 HR INCIDENTAL USE

1 HR FIRE & SMOKE BARRIER

C3-123C3-123

C3-160C3-160

C3-161C3-161

C3-164C3-164

C3-171C3-171

3S-63S-6

C3-65C3-65

3A-1233A-123

3A-1273A-1273A-1293A-1293A-1303A-130

3A-1313A-131

3A-1323A-132

3A-1333A-133

3A-1343A-134

3A-1353A-135

3A-1253A-125

3A-1283A-128

3A-1243A-124

3A-1263A-126

3F-131O3F-131O

3H-1013H-101

3G-1153G-115

3G-1163G-116

3G-1173G-117

3G-1183G-118 3G-1193G-119

3G-1203G-1203G-1213G-1213G-1223G-122

3G-1013G-101

3G-1043G-104

3G-104A3G-104A 3G-104B3G-104B

3G-104C3G-104C

3G-1063G-106 3G-1083G-108

3G-1123G-112

3G-110A3G-110A

3G-1003G-100

3G-101A3G-101A

3G-1023G-102

3G-1033G-103

3G-1053G-105

3G-1073G-107

3G-1093G-109 3G-109A3G-109A

3G-1103G-110

3H-1233H-123

3G-1243G-124

3H-1003H-100

3H-105B3H-105B

3H-1223H-122

3G-1133G-113 3G-1143G-1143G-1233G-123

3G-1113G-111

3H-100A3H-100A 3H-100B3H-100B

3H-105A3H-105A

3L-1033L-103EE

C-6C-6 on e-ei gh th in ch o ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in es ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

NOT FOR CONSTRUCTION

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

TRUE NORTH

PLAN NORTH

KEYPLANA/E:

TRIPLE C - The A/E Group

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

A

B D

EF

G

H

J

K

L

M

C

As indicated

B

IM

/6

-2

-7

E

H R

M I n fr a s tr u c tu re U p g ra d e s M

P L S

V A

M C

/6 -2

-7

.M

E H

R M

.A R

C H

.B .L

.r v t

/5

/2

:4 :5

A

M

05/06/2022 M. Perkins K. McDermott

618-21-700

1383 - 70A-403F

ARCHITECTURAL ENLARGED VIEWS - THIRD

LEVEL AREA F

1 Veterans Drive, Minneapolis, MN 55417

B70

EHRM INFRASTRUCTURE

UPGRADESFINAL BID DOCUMENTS

1" = 10'-0" F3

ARCHITECTURAL FLOOR PLAN - THIRD LEVEL AREA F

NOT USED

/06

/20

GENERAL NOTES

EXISTING CONSTRUCTION TO REMAIN

EXISTING CONSTRUCTION TO BE DEMOLISHED

NEW CONSTRUCTION, WITH PARTITION TYPE

A

A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT

REQUIREMENTS AND PROJECT LOCATION DRAWINGS.

B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES

INFORMATION.

C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL

SYSTEMS INFORMATION.

D. NEW IT CLOSETS SHALL BE SMOKE RATED AND COMPLY WITH THE

LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS

STANDARDS.

E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.

F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.

G. SEE TYPICAL CEILING DETAILS ON SHEET A-531

PARTITION RATING GRAPHICS:

2 HR FIRE SHAFT

1 HR SMOKE BARRIER

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION:

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND

SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.

1 HR INCIDENTAL USE

1 HR FIRE & SMOKE BARRIER

TELECOM

ROOM

(ORANGE-STACK)

3H-114

ACTUAL: 242 SF

PROG: 170 SF

PRIMARY

TELECOM

ROOM

(PINK-STACK)

3F-122E

ACTUAL: 222 SF

PROG: 170 SF

PROGRAM

3F-1213F-121 3F-127-143F-127-143F-127-133F-127-133F-127-123F-127-123F-127-113F-127-113F-127-103F-127-10

3F-127-93F-127-93H-105B3H-105B 3H-105A3H-105A

TELECOM

ROOM

3F-122A3F-122A

ELECTRICAL

ROOM

3F-122B3F-122B

ELECTRICAL

ROOM

3F-122C3F-122C

TELECOM

ROOM

3F-122D3F-122D

3L-123A3L-123A

3L-1223L-122

3L-119A3L-119A

3L-1193L-119

3L-1253L-125

3L-1273L-127

C5C5

3L-1133L-113

3L-1143L-114

3L-1023L-102

3L-1033L-103 3L-1043L-104 3L-1053L-105

3L-1063L-106

3L-1073L-107

3L-1083L-108 3L-1093L-109

3L-1103L-110

3L-1113L-111

3L-1123L-112

3L-1153L-115

3L-1163L-116 3L-1183L-118

3L-1203L-120

3L-1213L-121

3L-1173L-117

3L-120A3L-120A3L-127A3L-127A 3L-105A3L-105A

3L-109A3L-109A

3L-115A3L-115A3L-103A3L-103A

3L-103B3L-103B

3L-104A3L-104A

3L-104B3L-104B

3L-121A3L-121A

3L-124A3L-124A3L-126A3L-126A 3L-128A3L-128A3L-129A3L-129A

3L-132A3L-132A3L-133A3L-133A 3L-135A3L-135A

3L-102A3L-102A

3H-1193H-119

3L-1013L-101

3H-1173H-117

3H-1123H-112

3H-1133H-113 3H-1163H-116

3H-1183H-118

3H-1213H-121

3H-117B3H-117B

3H-117A3H-117A

3H-117D3H-117D

3L-1303L-130

3L-1313L-131

3F-1223F-122

3L-1233L-123

3L-1243L-1243L-1263L-126

3L-1283L-1283L-1293L-1293L-1323L-1323L-1333L-1333L-1343L-1343L-1353L-135

3H-117C3H-117C

3H-1203H-120 3H-1093H-109

M-8M-8

EE

C3-66C3-66

C3-63C3-63

C3-64C3-64

C-6C-6

C3-62C3-62

C3-61AC3-61A

C3-57C3-57

C3-58C3-58 C3-56AC3-56A

C3-61C3-61

C3-59C3-59

C3-60C3-60

C3-56C3-56

C3-55C3-55

C3-54C3-54

3K-1383K-138 3K-1013K-101 3K-1023K-102

3K-102A3K-102A

3K-1373K-137

3K-137A3K-137A

C3-73C3-73

3J-1063J-106

3H-1113H-111

3J-143A3J-143A

3H-1043H-104

3H-1053H-105

C3-173C3-173

C3-68C3-68

3H-1103H-110

3H-105C3H-105C

3J-1433J-143

70A-403G

C2

70A-403G

C4

70A-403G

B2

70A-403G

B4

TELECOM

ROOM

(ORANGE-STACK)

3H-114

ACTUAL: 242 SF

PROG: 170 SF

PRIMARY

B

B

B

B

3H -1

A

70A-100

D8

TYP ALL

TR WALLS

8 8

TELECOM

ROOM

(ORANGE-STACK)

3H-114

ACTUAL: 242 SF

PROG: 170 SF

PRIMARY

'-1

0"

TELECOM

ROOM

(PINK-STACK)

3F-122E

ACTUAL: 222 SF

PROG: 170 SF

PROGRAM

B

B

B

A4

A

3F -1

E

ALIGN

'-6

/8

TELECOM

ROOM

(PINK-STACK)

3F-122E

ACTUAL: 222 SF

PROG: 170 SF

PROGRAM

3F-1223F-122

HOSPITALIST

3H-1143H-114

GOLD

MEDICINE

3H-1153H-115

HOSPITALIST

3H-1143H-114

GOLD

MEDICINE

3H-1153H-115

3F-1223F-122 on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

NOT FOR CONSTRUCTION

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

TRUE NORTH

PLAN NORTH

KEYPLANA/E:

TRIPLE C - The A/E Group

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

A

B D

EF

G

H

J

K

L

M

C

As indicated

B

IM

/6

-2

-7

E

H R

M I n fr a s tr u c tu re U p g ra d e s M

P L S

V A

M C

/6 -2

-7

.M

E H

R M

.A R

C H

.B .L

.r v t

/5

/2

:4 :0

A

M

05/06/2022 M. Perkins K. McDermott

618-21-700

1383 - 70A-403G

ARCHITECTURAL ENLARGED VIEWS - THIRD

LEVEL AREA G

1 Veterans Drive, Minneapolis, MN 55417

B70

EHRM INFRASTRUCTURE

UPGRADESFINAL BID DOCUMENTS

1" = 10'-0" F2

ARCHITECTURAL FLOOR PLAN - THIRD LEVEL AREA G

1/4" = 1'-0" C2

ARCHITECTURAL FLOOR PLAN - THIRD LEVEL

- ROOM 3H-114 - DEMO

1/4" = 1'-0"

C4

ARCHITECTURAL FLOOR PLAN - THIRD LEVEL

- ROOM 3H-114 - NEW

1/4" = 1'-0"

C6

ARCHITECTURAL RCP - THIRD LEVEL - ROOM

3H-114 - DEMO

1/4" = 1'-0"

C8

ARCHITECTURAL RCP - THIRD LEVEL - ROOM

3H-114 - NEW

1/4" = 1'-0" B2

ARCHITECTURAL FLOOR PLAN - THIRD LEVEL

- ROOM 3F-122E - DEMO

1/4" = 1'-0"

B4

ARCHITECTURAL FLOOR PLAN - THIRD LEVEL

- ROOM 3F-122E - NEW

1/4" = 1'-0"

B8

ARCHITECTURAL RCP - THIRD LEVEL - ROOM

3F-122E - NEW

1/4" = 1'-0"

B6

ARCHITECTURAL RCP - THIRD LEVEL - ROOM

3F-122E - DEMO

1 REMOVE EXISTING WALL AND FRAMING.

2 REMOVE EXISTING DOOR AND FRAME. INFILL OPENING TO MATCH

ADJACENT CONSTRUCTION AND FINISH FOR CONTINUOUS SURFACE.

3 REMOVE FLOORING AND WALL BASE IN ROOM.

4 NEW 45 MIN SMOKE RATED DOOR. SEE DOOR SCHEDULE AND

SPECIFICATIONS FOR ADDITIONAL INFORMATION. COORDINATE

DOOR AND FRAME WITH ACCESS CONTROL HARDWARE.

5 EXISTING WALLS TO BECOME 1HR FIRE AND SMOKE-RATED. EXTEND

TO DECK AS REQUIRED. PATCH AND SEAL ALL PENETRATIONS AS

NECESSARY.

6 PROVIDE NEW FIRE EXTINGUISHER CABINET WITH A TYPE 2A:10B:C

CLEAN AGENT FIRE EXTINGUISHER LOCATED NO GREATER THAN 75

FEET AWAY FROM THE NEW TR. CONTRACTOR TO COORDINATE THE

NEW LOCATION WITH THE COR. CONTRACTOR SHALL BID A NEW FEC

FOR EACH TR IN THE SCOP

7 REMOVE EXISTING DOOR AND FRAME.

8 REMOVE EXISTING ACOUSTICAL CEILING AND LIGHTS. MODIFY

AND/OR PROVIDE ADDITIONAL SUPPORTS AS REQUIRED FOR

EXISTING CEILING ITEMS TO REMAIN.

9 EXISTING OPEN TO DECK CEILING TO REMAIN.

10 TELECOM ROOM TO BE OPEN TO DECK ABOVE.

11 PROVIDE TEMPORARY AIR TIGHT BARRIER AROUND WORK AREA

DURING ANY ACTIVITIES WHICH PRODUCE DUST – TYPICAL.

/06

GENERAL NOTES

EXISTING CONSTRUCTION TO REMAIN

EXISTING CONSTRUCTION TO BE DEMOLISHED

NEW CONSTRUCTION, WITH PARTITION TYPE

A

A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT

REQUIREMENTS AND PROJECT LOCATION DRAWINGS.

B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES

INFORMATION.

C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL

SYSTEMS INFORMATION.

D. NEW IT CLOSETS SHALL BE SMOKE RATED AND COMPLY WITH THE

LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS

STANDARDS.

E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.

F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.

G. SEE TYPICAL CEILING DETAILS ON SHEET A-531

PARTITION RATING GRAPHICS:

2 HR FIRE SHAFT

1 HR SMOKE BARRIER

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION:

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND

SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.

1 HR INCIDENTAL USE

1 HR FIRE & SMOKE BARRIER

3H-117D3H-117D3K-1383K-138 3K-1013K-101 3K-1023K-102

3K-102A3K-102A

3K-103A3K-103A

3K-103B3K-103B

3K-104A3K-104A

3K-104B3K-104B

3K-105A3K-105A

3K-109A3K-109A

3K-1063K-106

3K-1313K-131

3K-1113K-111 3K-1123K-112

3K-1133K-113

3K-1143K-114 3K-1153K-115

3K-1163K-116

3K-1173K-117

3K-1183K-118

3K-1193K-119

3K-1203K-120

3K-1213K-121

3K-1223K-122

3K-1233K-123

3K-1243K-124

3K-1253K-125

3K-1263K-126

3K-1273K-127

3K-1283K-128

3K-1293K-129

3K-1303K-130

3K-1323K-132

3K-1343K-134

3K-1353K-135

3K-1363K-136

3K-1373K-137

3K-1033K-103

3K-1043K-104

3K-1053K-105

3K-1083K-108

3K-1093K-109

3K-128A3K-128A

3K-115A3K-115A

3K-117A3K-117A

3K-120A3K-120A

3K-121A3K-121A

TELECOM

ROOM

3K-122A3K-122A

ELECTRICAL

ROOM

3K-122B3K-122B

3K-124A3K-124A

3K-125A3K-125A

3K-127A3K-127A

3K-129A3K-129A

3K-132A3K-132A

3K-135A3K-135A

3K-137A3K-137A

3K-130A3K-130A

3K-1073K-107

3K-1103K-110

C3-76C3-76

C3-75C3-75 C3-74C3-74

3K-1333K-133

C3-78C3-78

C7C7

C3-77C3-77

C3-73C3-73

C3-81C3-81

C3-80C3-80

C3-79C3-79 on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

NOT FOR CONSTRUCTION

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

TRUE NORTH

PLAN NORTH

KEYPLANA/E:

TRIPLE C - The A/E Group

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

A

B D

EF

G

H

J

K

L

M

C

As indicated

B

IM

/6

-2

-7

E

H R

M I n fr a s tr u c tu re U p g ra d e s M

P L S

V A

M C

/6 -2

-7

.M

E H

R M

.A R

C H

.B .L

.r v t

/5

/2

:4 :0

A

M

05/06/2022 M. Perkins K. McDermott

618-21-700

1383 - 70A-403H

ARCHITECTURAL ENLARGED VIEWS - THIRD

LEVEL AREA H

1 Veterans Drive, Minneapolis, MN 55417

B70

EHRM INFRASTRUCTURE

UPGRADESFINAL BID DOCUMENTS

1" = 10'-0" F6

ARCHITECTURAL FLOOR PLAN - THIRD LEVEL AREA H

NOT USED

/06

GENERAL NOTES

EXISTING CONSTRUCTION TO REMAIN

EXISTING CONSTRUCTION TO BE DEMOLISHED

NEW CONSTRUCTION, WITH PARTITION TYPE

A

A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT

REQUIREMENTS AND PROJECT LOCATION DRAWINGS.

B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES

INFORMATION.

C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL

SYSTEMS INFORMATION.

D. NEW IT CLOSETS SHALL BE SMOKE RATED AND COMPLY WITH THE

LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS

STANDARDS.

E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.

F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.

G. SEE TYPICAL CEILING DETAILS ON SHEET A-531

PARTITION RATING GRAPHICS:

2 HR FIRE SHAFT

1 HR SMOKE BARRIER

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION:

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND

SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.

1 HR INCIDENTAL USE

1 HR FIRE & SMOKE BARRIER

3H-105B3H-105B

3K-137A3K-137A

ELECTRICAL

ROOM

3J-124C3J-124C

TELECOM

ROOM

3J-124D3J-124D

TELECOM

ROOM

3J-124A3J-124A

3J-1013J-101

3J-1023J-1023J-1033J-103

3J-1043J-104 3J-1053J-105

3J-1063J-106

3J-1073J-107

3J-1083J-108

3J-1093J-109

3J-1103J-1103J-1113J-111

3J-1123J-1123J-1133J-113

3J-1143J-1143J-1153J-1153J-1163J-116

3J-1173J-1173J-1183J-118

3J-1193J-1193J-1203J-120

3J-1213J-121

3J-1223J-1223J-1233J-123

3J-107A3J-107A

3J-1253J-125

3J-1263J-126

3J-1273J-127

3J-1283J-128

3J-1323J-132

3J-1313J-131

3J-1303J-130 3J-1373J-137

3J-1413J-141

3H-1043H-104

3J-1243J-124

ELECTRICAL

ROOM

3J-124B3J-124B

3J-141A3J-141A

3J-142A3J-142A

C3-93C3-93

3J-126A3J-126A

C3-98C3-98

C3-97C3-97

C3-173C3-173

C3-68C3-68

C3-100C3-100

C3-99C3-99

C3-92C3-92C3-95C3-95

C3-96C3-96

3J-1423J-142

C3-90C3-90

3J-1333J-133 3J-1343J-134 3J-138B3J-138B

3J-1363J-136

3J-1353J-135 C8C8

3J-1383J-138

3J-138A3J-138A

3J-1393J-139

3J-139A3J-139A

C3-84C3-84

3J-1403J-140

3J-140A3J-140A

3H-105C3H-105C

3J-1433J-143 on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

NOT FOR CONSTRUCTION

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

TRUE NORTH

PLAN NORTH

KEYPLANA/E:

TRIPLE C - The A/E Group

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

A

B D

EF

G

H

J

K

L

M

C

As indicated

B

IM

/6

-2

-7

E

H R

M I n fr a s tr u c tu re U p g ra d e s M

P L S

V A

M C

/6 -2

-7

.M

E H

R M

.A R

C H

.B .L

.r v t

/5

/2

:4 :1

A

M

05/06/2022 M. Perkins K. McDermott

618-21-700

1383 - 70A-403J

ARCHITECTURAL ENLARGED VIEWS - THIRD

LEVEL AREA J

1 Veterans Drive, Minneapolis, MN 55417

B70

EHRM INFRASTRUCTURE

UPGRADESFINAL BID DOCUMENTS

1" = 10'-0" F2

ARCHITECTURAL FLOOR PLAN - THIRD LEVEL AREA J

NOT USED

/06

GENERAL NOTES

EXISTING CONSTRUCTION TO REMAIN

EXISTING CONSTRUCTION TO BE DEMOLISHED

NEW CONSTRUCTION, WITH PARTITION TYPE

A

A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT

REQUIREMENTS AND PROJECT LOCATION DRAWINGS.

B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES

INFORMATION.

C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL

SYSTEMS INFORMATION.

D. NEW IT CLOSETS SHALL BE SMOKE RATED AND COMPLY WITH THE

LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS

STANDARDS.

E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.

F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.

G. SEE TYPICAL CEILING DETAILS ON SHEET A-531

PARTITION RATING GRAPHICS:

2 HR FIRE SHAFT

1 HR SMOKE BARRIER

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION:

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND

SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.

1 HR INCIDENTAL USE

1 HR FIRE & SMOKE BARRIER

TELECOM

ROOM

(BLUE-STACK)

3N-101A

ACTUAL: 170 SF

PROG: 170 SF

PRIMARY

3P-1033P-103

3P-1053P-105

3P-1063P-106

3P-1293P-129

3P-1073P-107

3P-1083P-1083P-1103P-110

3P-1123P-112

3P-1133P-113

3P-1153P-115

3P-1173P-117 3P-1183P-118

3P-1193P-1193P-1203P-120

3P-1213P-121

3P-1223P-122 3P-1233P-123

3P-1243P-124

3P-1253P-125

3P-1263P-126

3P-1273P-127

3P-1283P-128

3N-1013N-101

3P-1023P-102

3P-1043P-104

3P-1093P-109

3P-1113P-111

3P-1143P-114

3P-1163P-116

C3-105C3-105

C3-103C3-103

C3-102C3-102

C3-104C3-104 C3-101C3-101

3A-1033A-103

3M-1033M-103

3M-1063M-106

3M-1073M-107

3M-1083M-108

3M-1093M-109

3M-1123M-112 3M-1143M-114

3M-1153M-115

3M-1163M-116

3M-1173M-117

3M-117A3M-117A

3P-1303P-1303P-1013P-101

3N-1023N-102

3N-1033N-103

3M-112A3M-112A

C3-106C3-106

C3-127C3-127 on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

NOT FOR CONSTRUCTION

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

TRUE NORTH

PLAN NORTH

KEYPLANA/E:

TRIPLE C - The A/E Group

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

A

B D

EF

G

H

J

K

L

M

C

As indicated

B

IM

/6

-2

-7

E

H R

M I n fr a s tr u c tu re U p g ra d e s M

P L S

V A

M C

/6 -2

-7

.M

E H

R M

.A R

C H

.B .L

.r v t

/5

/2

:4 :1

A

M

05/06/2022 M. Perkins K. McDermott

618-21-700

1383 - 70A-403K

ARCHITECTURAL ENLARGED VIEWS - THIRD

LEVEL AREA K

1 Veterans Drive, Minneapolis, MN 55417

B70

EHRM INFRASTRUCTURE

UPGRADESFINAL BID DOCUMENTS

1" = 10'-0" F3

ARCHITECTURAL FLOOR PLAN - THIRD LEVEL AREA K

NOT USED

/06

GENERAL NOTES

EXISTING CONSTRUCTION TO REMAIN

EXISTING CONSTRUCTION TO BE DEMOLISHED

NEW CONSTRUCTION, WITH PARTITION TYPE

A

A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT

REQUIREMENTS AND PROJECT LOCATION DRAWINGS.

B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES

INFORMATION.

C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL

SYSTEMS INFORMATION.

D. NEW IT CLOSETS SHALL BE SMOKE RATED AND COMPLY WITH THE

LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS

STANDARDS.

E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.

F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.

G. SEE TYPICAL CEILING DETAILS ON SHEET A-531

PARTITION RATING GRAPHICS:

2 HR FIRE SHAFT

1 HR SMOKE BARRIER

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION:

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND

SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.

1 HR INCIDENTAL USE

1 HR FIRE & SMOKE BARRIER

TELECOM

ROOM

(BLUE-STACK)

3N-101A

ACTUAL: 170 SF

PROG: 170 SF

PRIMARY

M-4M-4

C3-125C3-125

C3-117C3-117

BB

C3-126C3-126

3A-1043A-104

3A-1363A-136

3A-1373A-137

3N-1013N-101

C3-105C3-105

3S-23S-2

3Q-1023Q-102

3Q-1033Q-103

3Q-1053Q-105

3Q-1073Q-107

3Q-1083Q-108

3Q-1113Q-111 3Q-1123Q-112

3Q-1133Q-113 3Q-1143Q-114

3Q-1223Q-122

3Q-1233Q-123

3Q-1243Q-124

3Q-1253Q-125

3Q-1263Q-126

3Q-1273Q-127

3Q-1283Q-128

3N-1073N-107

TELECOM

ROOM

3N-1083N-108

3M-1233M-123

3A-1013A-101

3A-1023A-102

3A-1033A-103

TELECOM

ROOM

3M-1013M-101

ELECTRICAL

ROOM

3M-1023M-102

3M-1033M-103

3M-1043M-104

3M-1053M-105

3M-1063M-106

3M-1073M-107

3M-1083M-108

3M-1093M-109

3S-73S-7

3M-1123M-112

3M-1133M-113

3M-1143M-114

3M-1153M-115

3M-1163M-116

3M-1173M-117

3M-1203M-120

3M-1213M-121

3M-117A3M-117A

3P-1303P-1303P-1013P-101

3N-1023N-102

3N-1033N-103

3N-1043N-104

3N-1053N-105

3S-83S-8

3Q-1013Q-101

3Q-1043Q-104

3Q-1103Q-110

3S-103S-10

3N-1063N-106

FF

GG

M2M2

3M-1183M-118

3M-1193M-119

ELECTRICAL

ROOM

3N-1093N-109

3Q-1063Q-106

3Q-1093Q-109

C3-113C3-113

C3-114C3-114

3M-112A3M-112A

3M-1703M-170

C3-107C3-107

C3-106C3-106

C3-108C3-108

C3-109C3-109

C3-110C3-110 C3-112C3-112

C3-127C3-127

C9C9

C10C10

M-3M-3

M-10M-10

3R-106D3R-106D3R-106F3R-106F3R-106H3R-106H3R-106K3R-106K

3R-121E3R-121E

3R-121D3R-121D

3R-121C3R-121C

3R-121B3R-121B 3R-106J3R-106J 3R-106I3R-106I 3R-106G3R-106G 3R-106B3R-106B

3R-106C3R-106C

3R-1033R-1033R-106A3R-106A 3R-1093R-1093R-121A3R-121A

3R-1063R-106

3R-121M3R-121M

3R-121F3R-121F

3R-121G3R-121G3R-121H3R-121H3R-121I3R-121I

3R-121J3R-121J

3R-121K3R-121K

3R-122A3R-122A

3R-122B3R-122B

3R-122C3R-122C

3R-122D3R-122D 3R-122e3R-122e 3R-122f3R-122f

3R-122g3R-122g

3R-122h3R-122h

3R-1223R-122

3R-1233R-123 3R-126A3R-126A 3R-126B3R-126B 3R-1193R-119

3R-1243R-124

3R-1253R-125

3R-126f3R-126f

3R-126e3R-126e

3R-1283R-128

3R-1293R-129

3R-126d3R-126d 3R-126c3R-126c

3R-1103R-110

3R-1113R-111

3R-1123R-112

3R-1143R-114

3R-1163R-116

3R-1183R-118

3R-1263R-126

3R-107A3R-107A

3R-107B3R-107B

3R-1133R-113

3R-1153R-115

3R-1173R-117

3R-117A3R-117A 3R-117B3R-117B

3R-117C3R-117C

3R-117D3R-117D

3R-102A3R-102A

3R-1073R-107

3R-1023R-102

3R-1013R-101

C3R152C3R152

C3R150C3R150C3R130C3R130

C3R128C3R128

3R-1213R-121

3R-100b3R-100b

3R-121n3R-121n

3R-1003R-100

ELECTRICAL

ROOM

3T-1053T-105

3V-1113V-111

3V-1123V-1123V-112a3V-112a3V-112b3V-112b

70A-403L

B4

70A-403L

B3

TELECOM

ROOM

(BLUE-STACK)

3N-101A

ACTUAL: 170 SF

PROG: 170 SF

PRIMARY

B

B A

B

B

A4

3N-101A

ALIGN

'-5

/8

70A-100

D8

TYP ALL

TR WALLS

2 4

TELECOM

ROOM

(BLUE-STACK)

3N-101A

ACTUAL: 170 SF

PROG: 170 SF

PRIMARY

3N-1013N-101

3N-1013N-101 on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

NOT FOR CONSTRUCTION

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

TRUE NORTH

PLAN NORTH

KEYPLANA/E:

TRIPLE C - The A/E Group

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

A

B D

EF

G

H

J

K

L

M

C

As indicated

B

IM

/6

-2

-7

E

H R

M I n fr a s tr u c tu re U p g ra d e s M

P L S

V A

M C

/6 -2

-7

.M

E H

R M

.A R

C H

.B .L

.r v t

/5

/2

:4 :2

A

M

05/06/2022 M. Perkins K. McDermott

618-21-700

1383 - 70A-403L

ARCHITECTURAL ENLARGED VIEWS - THIRD

LEVEL AREA L

1 Veterans Drive, Minneapolis, MN 55417

B70

EHRM INFRASTRUCTURE

UPGRADESFINAL BID DOCUMENTS

1" = 10'-0" F3

ARCHITECTURAL FLOOR PLAN - THIRD LEVEL AREA L

1 REMOVE FLOORING AND WALL BASE IN AREA.

2 REMOVE EXISTING RAMP TRANSITION. REPLACE WITH MODULAR

ADA COMPLIANT RAMP - FIELD VERIFY DIMENSIONS REQUIRED

AND SUBMIT FOR APPROVAL PRIOR TO ORDERING. BASIS OF

DESIGN - EZ ACCESS TRANSITIONS MODULAR ENTRY RAMP,

https://handiramp.com/product/ez-access-transitions-modular-entry-ramps/

OR EQUAL

3 NEW 45 MIN SMOKE RATED DOOR. SEE DOOR SCHEDULE AND

SPECIFICATIONS FOR ADDITIONAL INFORMATION. COORDINATE

DOOR AND FRAME WITH ACCESS CONTROL HARDWARE.

4 EXISTING OPEN TO DECK CEILING TO REMAIN.

5 TELECOM ROOM TO BE OPEN TO DECK ABOVE.

6 PROVIDE NEW FIRE EXTINGUISHER CABINET WITH A TYPE 2A:10B:C

CLEAN AGENT FIRE EXTINGUISHER LOCATED NO GREATER THAN

75 FEET AWAY FROM THE NEW TR. CONTRACTOR TO COORDINATE

THE NEW LOCATION WITH THE COR. CONTRACTOR SHALL BID A

NEW FEC FOR EACH TR IN THE SCOP

7 EXISTING EXTERIOR WALLS NO RATING REQUIRED

8 PROVIDE TRANSLUSCENT FILM ON INSIDE OF WINDOWS

1/4" = 1'-0" B3

ARCHITECTURAL FLOOR PLAN - THIRD LEVEL

- ROOM 3N-101A - DEMO

1/4" = 1'-0"

B4

ARCHITECTURAL FLOOR PLAN - THIRD LEVEL

- ROOM 3N-101A - NEW

1/4" = 1'-0"

B6

ARCHITECTURAL RCP - THIRD LEVEL - ROOM

3N-101A - DEMO

1/4" = 1'-0"

B7

ARCHITECTURAL RCP - THIRD LEVEL - ROOM

3N-101A - NEW

/06

GENERAL NOTES

EXISTING CONSTRUCTION TO REMAIN

EXISTING CONSTRUCTION TO BE DEMOLISHED

NEW CONSTRUCTION, WITH PARTITION TYPE

A

A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT

REQUIREMENTS AND PROJECT LOCATION DRAWINGS.

B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES

INFORMATION.

C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL

SYSTEMS INFORMATION.

D. NEW IT CLOSETS SHALL BE SMOKE RATED AND COMPLY WITH THE

LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS

STANDARDS.

E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.

F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.

G. SEE TYPICAL CEILING DETAILS ON SHEET A-531

PARTITION RATING GRAPHICS:

2 HR FIRE SHAFT

1 HR SMOKE BARRIER

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION:

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND

SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.

1 HR INCIDENTAL USE

1 HR FIRE & SMOKE BARRIER

TELECOM

ROOM

(YELLOW-STACK)

3Q-118G

ACTUAL: 128 SF

PROG: 170 SF

PRIMARY

3Q-1133Q-113 3Q-1143Q-114

3Q-1223Q-122

3Q-1103Q-110 C3-113C3-113 3R-106D3R-106D3R-106F3R-106F3R-106H3R-106H3R-106K3R-106K

3R-121E3R-121E

3R-121D3R-121D

3R-121F3R-121F

3R-121G3R-121G3R-121H3R-121H3R-121I3R-121I

3S-13S-1

3V-1043V-104

3V-104A3V-104A

3V-1063V-106

3V-1083V-108

3V-1103V-110

ELECTRICAL

ROOM

3T-1053T-105

3V-1113V-111

TELECOM

ROOM

3T-1063T-106

3T-1073T-107

TELECOM

ROOM

3T-1083T-108

3T-1103T-110

3V-1093V-1093V-1133V-113

3V-1153V-115 3V-1073V-107

3V-1053V-105 3V-1173V-117

3V-1213V-121

3V-1193V-119

3V-1033V-103

3V-1143V-114 3V-1293V-129

3V-1283V-128

3V-1273V-127 3V-1183V-118

3V-1163V-116

3V-1123V-1123V-112a3V-112a3V-112b3V-112b

3V-1223V-122

3V-1203V-1203V-1253V-125

3V-124E3V-124E

3V-134b3V-134b 3V-1243V-124 3V-1233V-123

3V-124b3V-124b

3V-124c3V-124c

3V-1303V-130

3V-130a3V-130a 3V-131a3V-131a

3V-1263V-126

3V-1313V-131

3V-1673V-167

3V-1473V-147 3V-1333V-133

3V-133a3V-133a3V-132a3V-132a 3V-149a3V-149a3V-147a3V-147a

3V-1493V-149 3V-1323V-132

3V-101O3V-101O3V-101N3V-101N

3V-137b3V-137b 3V-1373V-137

3V-137a3V-137a

3V-134a3V-134a

3V-1343V-1343V-1353V-1353V-1363V-136

ELECTRICAL

ROOM

3Q-118D3Q-118D

TELECOM

ROOM

3Q-118F3Q-118F

ELECTRICAL

ROOM

3Q-118E3Q-118E

TELECOM

ROOM

3Q-118A3Q-118A

TELECOM

ROOM

3Q-118C3Q-118C

3V-1433V-143

3V-1443V-144

3V-1453V-145

3V-1463V-146

3V-1483V-148

3V-1503V-150

3V-1513V-151

3V-1523V-152

3V-1533V-153

3V-1543V-154 3V-1583V-158

3V-1603V-160

3V-1613V-161 3V-1633V-163

3V-1643V-164

3V-1553V-155

3V-1563V-156 3V-1573V-157 3V-1593V-159 3V-1623V-162 3V-1653V-165 3V-1663V-166

3Q-1153Q-115

3Q-1193Q-1193Q-1203Q-120

3Q-1213Q-121

3Q-1183Q-118

ELECTRICAL

ROOM

3Q-118B3Q-118B

3Q-1163Q-116

3Q-1173Q-117

3V-1383V-1383V-1393V-1393V-1403V-1403V-1413V-141

3V-1423V-142

M-5M-5

3V-1023V-102

3V-1013V-101

3V-101A3V-101A

3V-101B3V-101B

3V-101C3V-101C

3V-101D3V-101D

3V-101E3V-101E

3V-101F3V-101F

3V-101G3V-101G 3V-101H3V-101H 3V-101I3V-101I

3V-101J3V-101J

3V-101K3V-101K

3V-101M3V-101M

C3-187C3-187

C3-189C3-189

C3-186C3-186

C3-185C3-185

C3-184C3-184

C3-138C3-138

3V-160A3V-160A

C3-135C3-135

C3-133C3-133

3V-1003V-100

3V-100A3V-100A

3V-1683V-168

ELECTRICAL

ROOM

3T-1093T-109

C3-182C3-182 C3-181C3-181

C3-180C3-180

C3-183C3-183

C3-179C3-179

3V-1753V-175

3V-102A3V-102A

3V-117A3V-117A

3V-118A3V-118A

C3-111C3-111

C3-110C3-110 C3-112C3-112

3V-124A3V-124A

70A-403M

B3

70A-403M

B4

3" 3'

-4 "7

TELECOM

ROOM

(YELLOW-STACK)

3Q-118G

ACTUAL: 128 SF

PROG: 170 SF

PRIMARY

B

B

B

B

3Q-118G ALIGN

16'-3 5/8"

A

A4

9D

T Y

P A

L L

T R

W A

L L S

TELECOM

ROOM

(YELLOW-STACK)

3Q-118G

ACTUAL: 128 SF

PROG: 170 SF

PRIMARY

3Q-1183Q-118 3Q-1183Q-118 on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

NOT FOR CONSTRUCTION

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

TRUE NORTH

PLAN NORTH

KEYPLANA/E:

TRIPLE C - The A/E Group

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

A

B D

EF

G

H

J

K

L

M

C

As indicated

B

IM

/6

-2

-7

E

H R

M I n fr a s tr u c tu re U p g ra d e s M

P L S

V A

M C

/6 -2

-7

.M

E H

R M

.A R

C H

.B .L

.r v t

/5

/2

:4 :3

A

M

05/06/2022 M. Perkins K. McDermott

618-21-700

1383 - 70A-403M

ARCHITECTURAL ENLARGED VIEWS - THIRD

LEVEL AREA M

1 Veterans Drive, Minneapolis, MN 55417

B70

EHRM INFRASTRUCTURE

UPGRADESFINAL BID DOCUMENTS

1" = 10'-0" F3

ARCHITECTURAL FLOOR PLAN - THIRD LEVEL AREA M

1/4" = 1'-0" B3

ARCHITECTURAL FLOOR PLAN - THIRD LEVEL

- ROOM 3Q-118G - DEMO

1/4" = 1'-0"

B4

ARCHITECTURAL FLOOR PLAN - THIRD LEVEL

- ROOM 3Q-118G - NEW

1/4" = 1'-0"

B8

ARCHITECTURAL RCP - THIRD LEVEL - ROOM

3Q-118G - NEW

1/4" = 1'-0"

B6

ARCHITECTURAL RCP - THIRD LEVEL - ROOM

3Q-118G - DEMO

1 REMOVE FLOORING AND WALL BASE IN AREA.

2 NEW SMOKE RATED DOOR. SEE DOOR SCHEDULE AND

SPECIFICATIONS FOR ADDITIONAL INFORMATION. COORDINATE

DOOR AND FRAME WITH ACCESS CONTROL HARDWARE.

3 EXISTING WALLS TO BECOME 1HR FIRE AND SMOKE-RATED. EXTEND

TO DECK AS REQUIRED. PATCH AND SEAL ALL PENETRATIONS AS

NECESSARY.

4 PROVIDE NEW FIRE EXTINGUISHER CABINET WITH A TYPE 2A:10B:C

CLEAN AGENT FIRE EXTINGUISHER LOCATED NO GREATER THAN 75

FEET AWAY FROM THE NEW TR. CONTRACTOR TO COORDINATE THE

NEW LOCATION WITH THE COR. CONTRACTOR SHALL BID A NEW

FEC FOR EACH TR IN THE SCOPE OF WORK. SEE SPECIFICATION 10

44 13.

5 EXISTING OPEN TO DECK CEILING TO REMAIN.

6 TELECOM ROOM TO BE OPEN TO DECK ABOVE.

7 REMOVE PORTION OF WALL FOR NEW DOOR.

8 PROVIDE TEMPORARY AIR TIGHT BARRIER AROUND WORK AREA

DURING ANY ACTIVITIES WHICH PRODUCE DUST – TYPICAL.

/06

GENERAL NOTES

EXISTING CONSTRUCTION TO REMAIN

EXISTING CONSTRUCTION TO BE DEMOLISHED

NEW CONSTRUCTION, WITH PARTITION TYPE

A

A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT

REQUIREMENTS AND PROJECT LOCATION DRAWINGS.

B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES

INFORMATION.

C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL

SYSTEMS INFORMATION.

D. NEW TELECOM ROOMS SHALL BE 1 HR FIRE AND SMOKE RATED AND

COMPLY WITH THE LATEST VA PHYSICAL SECURITY STANDARDS, AND

CAMPUS STANDARDS.

E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.

F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.

G. SEE TYPICAL CEILING DETAILS ON SHEET A-531

PARTITION RATING GRAPHICS:

2 HR FIRE SHAFT

1 HR SMOKE BARRIER

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION:

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND

SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.

1 HR INCIDENTAL USE

1 HR FIRE & SMOKE BARRIER

HHJJKKLLMMNNPPQQRRSSTTUUVV

70A-404A

B3

70A-404A

B2

TELECOM

ROOM

4U-1014U-101

TELECOM

ROOM

4U-100A4U-100A

4D-1224D-122

TELECOM

ROOM

4D-122A4D-122A

ELECTRICAL

ROOM

4D-122B4D-122B

4S-94S-9

4U-1034U-103

4U-104A4U-104A 4U-1044U-104

4U-1054U-105

4U-1064U-106

ELECTRICAL

ROOM

4U-1074U-107

TELECOM

ROOM

4U-1084U-108

4S-130A4S-130A

4S-130B4S-130B

4S-130C4S-130C

4S-130D4S-130D

4S-130E4S-130E

4S-130F4S-130F

4S-130G4S-130G4S-130H4S-130H

4S-1324S-132

4S-1354S-135

4S-1364S-136

4S-1374S-137

4S-1384S-138

4S-1394S-139

4S-1404S-140

4S-1414S-141

4S-1424S-142

4S-1434S-143

4S-1444S-144

4S-1454S-145

4S-1334S-133

4U-1004U-100

4T-1054T-105

C4-197C4-197

C4-4C4-4

C4-23C4-23 4U-1094U-109 C4-41C4-41

C4-22C4-22

4S-1304S-130

4S-1314S-131

4S-1344S-134

C4-1C4-1

C4-2C4-2

C4-6C4-6 C4-7C4-7 C4-8C4-8

C4-9C4-9

4U-104C4U-104C

C4-11C4-11

C4-12C4-12

C4-13C4-13

C4-14C4-14

C4-15C4-15

C4-16C4-16

C4-8AC4-8A

4U-104D4U-104D4U-104B4U-104B

4E-1534E-153

4S-1294S-129

4D-1474D-147 4D-1484D-148 4D-1494D-149 4D-1504D-150 4D-1514D-151 4D-1524D-152

4D-1464D-146 4D-1454D-145 4D-1444D-144

4D-1374D-137

4D-1344D-134 4D-1354D-135 4D-1364D-136

4D-137A4D-137A

4D-1384D-138

4D-1434D-143

4D-1424D-142

4D-1394D-139

4D-1414D-141

4D-1404D-140

4D-1334D-133 4D-132A4D-132A 4D-1324D-132

4D-1214D-121 4D-1234D-123 4D-1244D-124

4D-1254D-125

4D-1314D-131

4D-1264D-126 4D-1274D-127

4D-1304D-130 4D-1294D-129

4D-1284D-128

C4D-036C4D-036

C4D-037C4D-037

4S-1294S-129

4D-1264D-126 4D-1274D-127 4D-1284D-128

B

B

A3

A

B B

A

B

B

TELECOM

ROOM

4U-100A4U-100A

94U-100A

12'-11"

'-3

/4

V .I.

F

'-0

4' -0

1'

-0

TELECOM

ROOM

4U-100A4U-100A on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

TRUE NORTH

PLAN NORTH

KEYPLANA/E:

TRIPLE C - The A/E Group

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

A

B D

E F

G

H

J

K

L

M

C

As indicated

B

IM

/6

-2

-7

E

H R

M I n fr a s tr u c tu re U p g ra d e s

M P

L S

V A

M C

/6 -2

-7

.M

E H

R M

.A R

C H

.B .L

.r v t

/5

/2

:2 :4

A

M

05/06/2022 M. Perkins K. McDermott

618-21-700

1383 - 70A-404A

ARCHITECTURAL ENLARGED VIEWS -

FOURTH LEVEL AREA A

1 Veterans Drive, Minneapolis, MN 55417

B70

EHRM INFRASTRUCTURE

UPGRADESFINAL BID DOCUMENTS

1 NEW 45 MIN SMOKE RATED DOOR. SEE DOOR SCHEDULE AND

SPECIFICATIONS FOR ADDITIONAL INFORMATION. COORDINATE

DOOR AND FRAME WITH ACCESS CONTROL HARDWARE.

2 EXISTING WALLS TO BECOME 1 HR FIRE AND SMOKE-RATED.

EXTEND UP TO DECK AS REQUIRED. PATCH AND SEAL ALL

PENETRATIONS AS NECESSARY.

3 REMOVE ALL FLOORING AND MILLWORK IN THIS ROOM.

4 REMOVE EXISTING DROP CEILING. MODIFY AND/OR PROVIDE

ADDITIONAL SUPPORTS AS REQUIRED FOR EXISTING CEILING

ITEMS TO REMAIN (GRILLES, FIRE ALARMS, SENSORS, ETC.)

5 TELECOM ROOM TO BE OPEN TO DECK ABOVE.

6 MODIFY EXISTING ACOUSTICAL CEILING AS REQUIRED FOR NEW

WALLS.

7 PROVIDE NEW FIRE EXTINGUISHER CABINET WITH A TYPE 2A:10B:C

CLEAN AGENT FIRE EXTINGUISHER LOCATED NO GREATER THAN 75

FEET AWAY FROM THE NEW TR. CONTRACTOR TO COORDINATE

THE NEW LOCATION WITH THE COR. CONTRACTOR SHALL BID A

NEW FEC FOR EACH TR IN THE SCOPE OF WORK. SEE

SPECIFICATION 10 44 13.

8 EXISTING CONSTRUCTION TO BE DEMOLISHED FROM THIS

LOCATION

9 NEW FURRING WALL AT EXTERIOR WALL TO ENCLOSE WINDOW.

MAINTAIN 1/2" GAP BETWEEN EXISTING WALL INTERIOR FACE AND

NEW STUDS. MODIFY / REMOVE INTERIOR WINDOW TRIM AS

REQUIRED.

10 REMOVE PORTION OF WALL FOR NEW DOOR.

11 PROVIDE TEMPORARY AIR TIGHT BARRIER AROUND WORK AREA

DURING ANY ACTIVITIES WHICH PRODUCE DUST – TYPICAL.

SCALE: 1" = 10'-0"

F2

ARCHITECTURAL FLOOR PLAN -

FOURTH LEVEL AREA A

SCALE: 1/4" = 1'-0"

B3

ARCHITECTURAL FLOOR PLAN -

FOURTH LEVEL - RM 4U-100A - NEW

SCALE: 1/4" = 1'-0"

B2

ARCHITECTURAL FLOOR PLAN -

FOURTH LEVEL - RM 4U-100A - DEMO

SCALE: 1/4" = 1'-0"

B5

ARCHITECTURAL RCP - FOURTH

LEVEL - RM 4U-100A - DEMO

SCALE: 1/4" = 1'-0"

B7

ARCHITECTURAL RCP - FOURTH

LEVEL - RM 4U-100A - NEW

SCALE: 1" = 200'-0"

B8

BUILDING 70 - DIAMOND ANALYSIS

/06

GENERAL NOTES

EXISTING CONSTRUCTION TO REMAIN

EXISTING CONSTRUCTION TO BE DEMOLISHED

NEW CONSTRUCTION, WITH PARTITION TYPE

A

A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT

REQUIREMENTS AND PROJECT LOCATION DRAWINGS.

B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES

INFORMATION.

C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL

SYSTEMS INFORMATION.

D. NEW TELECOM ROOMS SHALL BE 1 HR FIRE AND SMOKE RATED AND

COMPLY WITH THE LATEST VA PHYSICAL SECURITY STANDARDS, AND

CAMPUS STANDARDS.

E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.

F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.

G. SEE TYPICAL CEILING DETAILS ON SHEET A-531

PARTITION RATING GRAPHICS:

2 HR FIRE SHAFT

1 HR SMOKE BARRIER

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION:

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND

SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.

1 HR INCIDENTAL USE

1 HR FIRE & SMOKE BARRIER

MMNNPPQQRRSSTTUUVVWWXX

4S-130G4S-130G4S-130H4S-130H4T-1054T-105

4S-1014S-101

4S-1024S-102

4S-1034S-103

4S-1044S-104

4S-1054S-105

4S-1184S-118

4S-1234S-123

4S-1244S-124

4S-1254S-125

4S-1264S-126

4S-1274S-127 4S-1284S-128

4S-1294S-129

4S-24S-2

4T-1024T-102

4T-102A4T-102A

4T-102C4T-102C

M-4M-4

TELECOM

ROOM

4T-1014T-101

AA

BB

4A-1054A-105

ELECTRICAL

ROOM

4A-1064A-106

4A-1074A-107

4A-1084A-108

ELECTRICAL

ROOM

4A-1094A-109

4A-1104A-110

4S-54S-5

4A-110A4A-110A

4A-107A4A-107A

4S-34S-3

C4-89C4-89

4B-1014B-101

4B-1024B-102

4B-1034B-103

4B-1044B-104

4B-1054B-105 4B-1064B-106 4B-1074B-107

4B-1084B-108

4B-1094B-109 4B-1104B-110

4B-1114B-111 4B-108B4B-108B

4B-1134B-113

4B-1144B-114

4B-1154B-115

4B-1164B-116

4B-1174B-117

4B-1184B-118

TELECOM

ROOM

4B-1194B-119

ELECTRICAL

ROOM

4B-1204B-120

4B-1214B-1214B-1224B-1224B-1234B-123

4B-1244B-124

4B-1254B-125

4B-1264B-126

4B-1274B-127

4B-1284B-128

4B-1294B-1294B-1304B-130

4B-1314B-131

4B-1324B-1324B-1334B-133

4B-1344B-134

4B-1354B-135

4B-1364B-136

4B-1374B-137

4B-1404B-140

4B-1414B-141

4B-1424B-1424B-1434B-143 4B-1444B-144

4B-1454B-145

4B-1464B-146

4B-1474B-147TELECOM

ROOM

4B-1494B-149

4B-1504B-150

4B-1514B-151 4B-1524B-1524B-1534B-1534B-1544B-154

4B-1554B-155 4B-1564B-156

4B-1574B-157

4B-101B4B-101B

4B-101C4B-101C

4B-108A4B-108A

4B-1584B-158 4B-1594B-159 4B-1604B-160

4S-44S-4

C4-181C4-181

C4-32C4-32

C4-86C4-86

4S-1214S-121

4S-1224S-122

4T-102B4T-102B

C4-76C4-76

C4-80C4-80

C4-82C4-82

C4-79C4-79

C4-84C4-84

C4-73C4-73

C4-72C4-72

C4-72AC4-72A

C4-74C4-74

C4-28C4-28 C4-29C4-29

C4-30C4-30

C4-183C4-183

C4-184C4-184

C4-185C4-185

C4-20C4-20

4B-1394B-139

C4-88C4-88

C4-182C4-182

C4-31C4-31

4S-1004S-100

4B-1004B-100

4B-108C4B-108C

4D-1214D-121

4D-1204D-120

4D-1084D-108

4C-1174C-117

C-10C-10 4A-1014A-101

4A-1024A-102

4A-1034A-103

M2M2

C9C9

4M-1054M-105

C4-90C4-90

C4-179C4-179 on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

TRUE NORTH

PLAN NORTH

KEYPLANA/E:

TRIPLE C - The A/E Group

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

A

B D

E F

G

H

J

K

L

M

C

As indicated

B

IM

/6

-2

-7

E

H R

M I n fr a s tr u c tu re U p g ra d e s

M P

L S

V A

M C

/6 -2

-7

.M

E H

R M

.A R

C H

.B .L

.r v t

/5

/2

:2 :5

A

M

05/06/2022 M. Perkins K. McDermott

618-21-700

1383 - 70A-404B

ARCHITECTURAL ENLARGED VIEWS -

FOURTH LEVEL AREA B

1 Veterans Drive, Minneapolis, MN 55417

B70

EHRM INFRASTRUCTURE

UPGRADESFINAL BID DOCUMENTS

1" = 10'-0" F3

ARCHITECTURAL FLOOR PLAN - FOURTH LEVEL AREA B

NOT USED

/06

GENERAL NOTES

EXISTING CONSTRUCTION TO REMAIN

EXISTING CONSTRUCTION TO BE DEMOLISHED

NEW CONSTRUCTION, WITH PARTITION TYPE

A

A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT

REQUIREMENTS AND PROJECT LOCATION DRAWINGS.

B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES

INFORMATION.

C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL

SYSTEMS INFORMATION.

D. NEW TELECOM ROOMS SHALL BE 1 HR FIRE AND SMOKE RATED AND

COMPLY WITH THE LATEST VA PHYSICAL SECURITY STANDARDS, AND

CAMPUS STANDARDS.

E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.

F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.

G. SEE TYPICAL CEILING DETAILS ON SHEET A-531

PARTITION RATING GRAPHICS:

2 HR FIRE SHAFT

1 HR SMOKE BARRIER

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION:

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND

SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.

1 HR INCIDENTAL USE

1 HR FIRE & SMOKE BARRIER

HHJJKKLLMM

TELECOM

ROOM

4C-1024C-102

C4-41C4-414E-1534E-153

4D-1014D-101

4D-1474D-147 4D-1484D-148 4D-1494D-149 4D-1504D-150 4D-1514D-151 4D-1524D-152

4D-1464D-146 4D-1454D-145 4D-1444D-144

4D-1374D-137

4D-1344D-134 4D-1354D-135…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .