618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-5.pdf

PDF 18 MB Posted

Attached to
EHRM Infrastructure Upgrades Construction Design-Bid Build Project at the Minneapolis VA Medical Center (VAMC)
Solicitation number
36C77622R0045
Issued by

About this file

This document provides details for a federal solicitation seeking construction design and build services. The solicitation will be issued as a Request for Proposal to upgrade infrastructure needed for an Electronic Health Record Modernization project at the Minneapolis VA Medical Center. The construction and commissioning must be completed in accordance with drawings and specifications provided by the architect-engineer. Services include building a new server room on the hospital roof and upgrades throughout multiple departments. The period of performance is approximately 450 calendar days from notice to proceed. The magnitude of construction is estimated between $20-50 million. The solicitation is set aside as a total small business preference and only offers from Service-Disabled Veteran-Owned Small Businesses will be considered. The NAICS code is 236220 and all questions must be submitted in writing to the agency contact.

View the file

Other files

File Type Posted
Technical Question Tracking Sheet Infra Upgrades FINAL.pdf PDF
36C77622R0045 0009.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-11.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-1.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-7.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-2.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-6.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-4.pdf PDF
618-21-700.ADD-001.Summary.Log.20220707.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-9.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-10.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-3.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-8.pdf PDF
36C77622R0045 0008.docx DOCX document
Technical Question Tracking Sheet - Infra Upgrades - FINAL.pdf PDF
36C77622R0045 0007.pdf PDF
36C77622R0045 0006.docx DOCX document
Technical Question Tracking Sheet - Infra Upgrades - Minneapolis.docx DOCX document
36C77622R0045 0005.docx DOCX document
36C77622R0045 0004.docx DOCX document
Technical Question Tracking Sheet - Infra Upgrades.docx DOCX document
36C77622R0045 0003.pdf PDF
Site Visit Sign In sheet.pdf PDF
36C77622R0045 0002.pdf PDF
36C77622R0045 0001.pdf PDF
36C77622R0045 - Update 5.23.22.docx DOCX document
618-21-700.MEHRM.FINAL.B70.20220506Part-7.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-11.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-33-36.zip ZIP file
618-21-700.MEHRM.FINAL.B76.20220506-REDUCED.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-48-52.zip ZIP file
36C77622R0045.docx DOCX document
618-21-700.MEHRM.FINAL.B70.20220506Part-21.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-25-28.zip ZIP file
618-21-700.MEHRM.FINAL.B70.20220506Part-4.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-23.pdf PDF
618-21-700.MEHRM.FINAL.B75.20220506-REDUCED.pdf PDF
618-21-700.MEHRM.FINAL_SPECIFICATIONS.20220506Part-2.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-45-47.zip ZIP file
618-21-700.MEHRM.FINAL.B70.20220506Part-6.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-13.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-20.pdf PDF
618-21-700.MEHRM.FINAL.B73.20220506-REDUCED.pdf PDF
618-21-700.MEHRM.FINAL.B49.20220506-REDUCED.pdf PDF
01 00 00 Appendix A - Bid Form Template.xlsx XLSX spreadsheet
618-21-700.MEHRM.FINAL.SITE.20220506-REDUCED.pdf PDF
618-21-700.MEHRM.FINAL.B222.20220506-REDUCED.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-12.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-16-17.zip ZIP file
618-21-700.MEHRM.FINAL.B70.20220506Part-29-32.zip ZIP file
Show 40 more

Latest 50 of 80 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PARTITION RATING GRAPHICS:

2 HR FIRE SHAFT

1 HR SMOKE BARRIER

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION:

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND

SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.

1 HR INCIDENTAL USE

70M-441

F5

70M-442

F7

4F-1474F-147 4F-1484F-148 4F-1494F-149 4F-1504F-150 4F-1514F-151

C4F-064C4F-064

4L-117B4L-117B

4F-121A4F-121A

4F-121B4F-121B

C4F-065C4F-065

C4-120C4-120

C4-122C4-122

4F-1474F-147

C4F-064C4F-064 4S-64S-6 4H-1214H-121

C4-116C4-116

4H-1204H-120

EE

C-6C-6

4L-1014L-101

4L-1084L-108 4L-1094L-109 4L-1104L-110 4L-1124L-112

4L-1134L-113 4L-1154L-115 4L-1174L-117 4L-117A4L-117A

4L-117A4L-117A2323

4F-121E4F-121E

4H-1144H-114

4H-1154H-115 4H-1164H-116

M-8M-8

4L-1034L-103 4L-1044L-104 4L-1054L-105

4L-1064L-106

4L-1074L-107 4L-1114L-111

4L-1144L-114 4L-118C4L-118C

4L-1214L-121

4L-1224L-122

4L-1234L-123

4L-1244L-124

4L-1254L-125

4L-1264L-1264L-1274L-127 4L-1284L-128

4L-1294L-129

4L-1304L-130

4L-1314L-131

4L-1324L-132

4L-1334L-133

4L-1344L-134

4L-1354L-135

4L-1364L-136

4L-1374L-137

4L-1384L-138

4L-1394L-139

4L-1404L-140

C5C5

4L-125A4L-125A

4F-121C4F-121C

4F-121D4F-121D

C4-117C4-117

C4-118C4-118

C4-119C4-119

C4-123C4-123

C4-126C4-126

C4-115C4-115

4L-1024L-102

4L-102A4L-102A

C4-124C4-124

4L-114A4L-114A 4L-1164L-116

4L-118A4L-118A 4L-118B4L-118B

4L-118D4L-118D4L-1184L-118

4K-1014K-101

4K-1024K-102

4K-1434K-143

4H-1084H-108

C4-114C4-114

4L-1394L-139

C4-125C4-125

4S-64S-6

4H-1144H-114

EE

C4-115C4-115

C4-137C4-137

70M-441

F2

70M-442

F5

1" CD

1" CD

1 1/2" CHWS

1 1/2" CHWR

TELECOM

ROOM

(ORANGE-STACK)

4H-1184H-118

TELECOM

ROOM

(PINK-STACK)

4F-121F4F-121F

3/4" CD

1 1/2" CHWR1 1/2" CHWS

1 1/4" CHWS

1 1/4" CHWR

3/4" CD

3/4" CD

1 1/4" CHWR

1 1/4" CHWS

on e-ei gh th in ch o ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in es ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

GENERAL NOTES

KEYNOTES

A

B D

TRUE NORTH

PLAN NORTH

E F

G

H

J

K

L

M

C

KEYPLANA/E:

TRIPLE C - The A/E Group

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

As indicated

B

IM

/6

-2

-7

E

H R

M I n fr a s tr u c tu re U p g ra d e s M

P L S

V A

M C

/6 -2

-7

.M

E H

R M

.M E

P .B

.L

.r v t

/7

/2

:4

:5

P

M

05/06/2022 M. Perkins G. Weaver

618-21-700

1383 - 70M-104G

MECHANICAL PLAN - FOURTH LEVEL AREA G

1 Veterans Drive, Minneapolis, MN 55417

B70

EHRM INFRASTRUCTURE

UPGRADESFINAL BID DOCUMENTS

1. PROVIDE PACKAGED NEW FAN COIL UNIT, CHILLED WATER PIPING,

CONDENSATE PIPING, THERMOSTAT AND BACNET CONTROLS MODULE

CONNECTED TO EXISTING CHILLED WATER SUPPLY/RETURN RISER. SEE RISER

DIAGRAMS FOR CONNECTIONS. LOCATE FAN COIL UNITS ABOVE DOOR.

PROVIDE DRAIN PAN WITH LEAK DETECTION CONNECTED TO BAS.

2. PROVIDE CONDENSATE PUMP, TO BE MOUNTED HIDDEN WITHIN THE INDOOR

UNIT, CAPABLE OF LIFTING UP 50 FEET WITH 8 FEET SUCTION AND 10 GPH

PUMPING CAPACITY. PROVIDE ELECTRICAL SERVICE FOR CONDENSATE PUMP

IF NOT FED FROM INDOOR UNIT. PROVIDE NEW CONDENSATE LINE FOR NEW

MECHANICAL EQUIPMENT, COORDINATE WITH VA. PROVIDE COORDINATION

DRAWINGS FOR EACH DRAIN LINE INSTALLATION PER 01 33 23 PRIOR TO

BEGINNING WORK.

3. PROVIDE NEW DEDICATED THERMOSTAT, COORDINATE FINAL LOCATION WITH

EXISTING AND NEW EQUIPMENT. THERMOSTATS SHALL BE DISPLAY ONLY WITH

CONTROLLABILITY THROUGH THE BMS.

4. PROVIDE BACNET CONTROLLER MOUNTED ADJACENT TO UNIT IN TR. CONNECT

WITH UTP CABLE TO EXISTING ETHERNET SWITCH IN LOCAL TR TO BE

ADDRESSABLE ON VA NETWORK/HVAC FMS.

5. PROVIDE NEW PUMPED CONDENSATE LINE, DROP DOWN ON WALL TO

DISCHARGE OVER EXISTING SINK BELOW, SECURE PIPING TO WALL. PIPE TO BE

CUT AT 45 DEGREE ANGLE AT OUTLET.

6. SEE ARCHITECTURAL DRAWINGS FOR CONTEXT.

7. PROVIDE ELECTRICAL CIRCUIT FOR EACH NEW CHILLED WATER FAN COIL UNIT.

SEE ELECTRICAL SHEETS.

8. EXISTING FACILITY HOUSE AIR THERMOSTAT TO REMAIN, PROTECT IN PLACE.

9. EXISTING CEILING MOUNTED SUPPLY AND RETURN AIR DEVICES TO REMAIN.

COORDINATE WITH REMOVAL OF EXISTING GYPSUM CEILING AND ALL OTHER

TRADES, RESUPPORT AIR DEVICE AS REQUIRED ABOVE CABLE TRAY AND

LIGHTING. SEE SHEET E-501 AND ARCHITECTURAL PLANS FOR ADDITIONAL

INFORMATION.

10. CONTRACTOR SHALL PROVIDE RATED PENETRATION TO MATCH WALL RATING

AT THIS LOCATION. SEE DETAILS ON M-500 SERIES SHEETS AND

SPECIFICATIONS FOR ADDITIONAL INFORMATION.

11. EXISTING PENETRATION TO REMAIN.

12. REBALANCE AIRFLOW AFTER CONSTRUCTION IS COMPLETE.

13. REMOVE RADIATORS AND CAP SERVICE LINES IN THE INTERSTITIAL SPACE.

14. CONNECT TO EXISTING CONDENSATE STACK.

A. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT, DUCTWORK AND PIPING

WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND SHALL

PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN

REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.

B. COORDINATE ALL DUCTWORK AND PIPE ROUTING AND ELEVATIONS WITH

OTHER TRADES IN ADVANCE OF INSTALLATION.

C. TEST AND BALANCE CONTRACTOR SHALL PROVIDE A PRE-

CONSTRUCTION TAB REPORT FOR THE EQUIPMENT AND ASSOCIATED

SYSTEMS SHOWN ON THE CONSTRUCTION DOCUMENTS AND UTILIZE

ALL AVAILABLE AS-BUILT DRAWINGS FROM THE OWNER. TEST AND

BALANCE CONTRACTOR SHALL VISIT SITE PRIOR TO CONSTRUCTION

AND VERIFY ALL EXISTING EQUIPMENT AND DEVICES, AND DEVELOP

THEIR TEST AND BALANCE FORMS INCLUDING DRAWINGS SHOWING

EQUIPMENT LOCATIONS, AIR DISTRIBUTION DEVICE LOCATIONS AND

TAG NUMBERS. IF THERE ARE LOCATIONS WHERE THE DRAWINGS DO

NOT REFLECT FIELD CONDITIONS, THE TEST AND BALANCE

CONTRACTOR SHALL INCLUDE THE AIRFLOW READINGS ON THE FORMS

AND LOCATE THE EQUIPMENT AND/OR AIR DEVICE ON THE DRAWINGS.

REFER TO SPECIFICATION SECTION 23 05 93 FOR MORE INFORMATION.

D. ALL DATA OBTAINED VIA TESTING AND MEASURING SHALL BE UTILIZED

TO ESTABLISH NEW HVAC SYSTEM PERFORMANCE AND BALANCE DATA

FOR THE RENOVATION. DATA SHALL BE FORWARDED TO THE PROJECT

ENGINEER FOR REVIEW AND COMMENT PRIOR TO COMMENCING THE

DEMOLITION AND/OR NEW WORK ASSOCIATED WITH THE FACILITY

RENOVATION.

E. THE CONTRACTOR SHALL PATCH, PAINT AND RETURN TO MATCH EXISTING

CONDITIONS FOR ANY FLOOR, WALL, OR CEILING THAT WAS DISTURBED TO

COMPLETE THIS PROJECT.

F. ALL NEW THERMOSTATS ARE TO BE MOUNTED AT A HEIGHT OF 54” ABOVE

FINISHED FLOOR. VERIFY FINAL THERMOSTAT LOCATIONS WITH VA.

G. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTS AND

ELEVATIONS.

H. ALL PIPING PLACED WITHIN INTERSTITIAL AREA.

NOTE: NOT ALL KEYNOTES ARE

USED ON EACH SHEET

SCALE: 1" = 10'-0"

F2

MECHANICAL PLAN - FIRST LEVEL

AREA G

1 Revision 1 Date 1

05/06/2022

ADDENDUM #1 07/07/2022

1 HR SMOKE BARRIER

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION:

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND

SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.

1 HR INCIDENTAL USE

4K-1014K-101

4K-1024K-102

4K-1034K-103

4K-1434K-143

4H-1084H-108

C4-127C4-127

4K-1244K-124

4K-1204K-120 4K-1214K-121

4K-1044K-104

4K-1054K-105

4K-1064K-106

4K-1074K-107

4K-1084K-108

4K-1094K-109 4K-1104K-110

4K-1114K-111

4K-1124K-112 4K-1134K-113

4K-1144K-114

4K-1154K-115

4K-1164K-116

4K-1174K-117

4K-1194K-119

4K-1224K-1224K-1234K-1234K-1254K-125

4K-1264K-126

4K-1274K-127 4K-1284K-128

4K-1294K-129

4K-1314K-131

4K-1324K-132

4K-1334K-133

4K-1344K-134

4K-1354K-135

4K-1364K-136

4K-1374K-137

4K-1384K-138 4K-1394K-139

4K-1404K-140

4K-1414K-141

4K-1424K-142

4K-102A4K-102A

4K-134A4K-134A

4K-136A4K-136A

4K-133A4K-133A

C-7C-7

4K-131A4K-131A

4K-140A4K-140A

4K-138A4K-138A

4K-1184K-118

4K-1304K-130

4K-121A4K-121A

C4-132C4-132

C4-133C4-133

C4-134C4-134

C4-131C4-131

4K-142A4K-142A

C4-135C4-135

4K-130A4K-130A

4K-124A4K-124A

4K-124B4K-124B

4H-108A4H-108A

4H-101A4H-101A

C4-138C4-138

C4-137C4-137

C4-135C4-135 on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

GENERAL NOTES

KEYNOTES

A

B D

TRUE NORTH

PLAN NORTH

E F

G

H

J

K

L

M

C

KEYPLANA/E:

TRIPLE C - The A/E Group

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

As indicated

B

IM

/6

-2

-7

E

H R

M I n fr a st ru ct u re

U p g ra d e s

M P

L S

V A

M C

/6 -2

-7

.M

E H

R M

.M E

P .B

.L

.r vt /6

/2

:2 :3

P

M

05/06/2022 M. Perkins G. Weaver

618-21-700

1383 - 70M-104H

MECHANICAL PLAN - FOURTH LEVEL AREA H

1 Veterans Drive, Minneapolis, MN 55417

B70

EHRM INFRASTRUCTURE

UPGRADESFINAL BID DOCUMENTS

1. PROVIDE PACKAGED NEW FAN COIL UNIT, CHILLED WATER PIPING,

CONDENSATE PIPING, THERMOSTAT AND BACNET CONTROLS MODULE

CONNECTED TO EXISTING CHILLED WATER SUPPLY/RETURN RISER. SEE RISER

DIAGRAMS FOR CONNECTIONS. LOCATE FAN COIL UNITS ABOVE DOOR.

PROVIDE DRAIN PAN WITH LEAK DETECTION CONNECTED TO BAS.

2. PROVIDE CONDENSATE PUMP, TO BE MOUNTED HIDDEN WITHIN THE INDOOR

UNIT, CAPABLE OF LIFTING UP 50 FEET WITH 8 FEET SUCTION AND 10 GPH

PUMPING CAPACITY. PROVIDE ELECTRICAL SERVICE FOR CONDENSATE PUMP

IF NOT FED FROM INDOOR UNIT. PROVIDE NEW CONDENSATE LINE FOR NEW

MECHANICAL EQUIPMENT, COORDINATE WITH VA. PROVIDE COORDINATION

DRAWINGS FOR EACH DRAIN LINE INSTALLATION PER 01 33 23 PRIOR TO

BEGINNING WORK.

3. PROVIDE NEW DEDICATED THERMOSTAT, COORDINATE FINAL LOCATION WITH

EXISTING AND NEW EQUIPMENT. THERMOSTATS SHALL BE DISPLAY ONLY WITH

CONTROLLABILITY THROUGH THE BMS.

4. PROVIDE BACNET CONTROLLER MOUNTED ADJACENT TO UNIT IN TR. CONNECT

WITH UTP CABLE TO EXISTING ETHERNET SWITCH IN LOCAL TR TO BE

ADDRESSABLE ON VA NETWORK/HVAC FMS.

5. PROVIDE NEW PUMPED CONDENSATE LINE, DROP DOWN ON WALL TO

DISCHARGE OVER EXISTING SINK BELOW, SECURE PIPING TO WALL. PIPE TO BE

CUT AT 45 DEGREE ANGLE AT OUTLET.

6. SEE ARCHITECTURAL DRAWINGS FOR CONTEXT.

7. PROVIDE ELECTRICAL CIRCUIT FOR EACH NEW CHILLED WATER FAN COIL UNIT.

SEE ELECTRICAL SHEETS.

8. EXISTING FACILITY HOUSE AIR THERMOSTAT TO REMAIN, PROTECT IN PLACE.

9. EXISTING CEILING MOUNTED SUPPLY AND RETURN AIR DEVICES TO REMAIN.

COORDINATE WITH REMOVAL OF EXISTING GYPSUM CEILING AND ALL OTHER

TRADES, RESUPPORT AIR DEVICE AS REQUIRED ABOVE CABLE TRAY AND

LIGHTING. SEE SHEET E-501 AND ARCHITECTURAL PLANS FOR ADDITIONAL

INFORMATION.

10. CONTRACTOR SHALL PROVIDE RATED PENETRATION TO MATCH WALL RATING

AT THIS LOCATION. SEE DETAILS ON M-500 SERIES SHEETS AND

SPECIFICATIONS FOR ADDITIONAL INFORMATION.

11. EXISTING PENETRATION TO REMAIN.

12. REBALANCE AIRFLOW AFTER CONSTRUCTION IS COMPLETE.

13. REMOVE RADIATORS AND CAP SERVICE LINES IN THE INTERSTITIAL SPACE.

14. CONNECT TO EXISTING CONDENSATE STACK.

A. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT, DUCTWORK AND PIPING

WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND SHALL

PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN

REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.

B. COORDINATE ALL DUCTWORK AND PIPE ROUTING AND ELEVATIONS WITH

OTHER TRADES IN ADVANCE OF INSTALLATION.

C. TEST AND BALANCE CONTRACTOR SHALL PROVIDE A PRE-

CONSTRUCTION TAB REPORT FOR THE EQUIPMENT AND ASSOCIATED

SYSTEMS SHOWN ON THE CONSTRUCTION DOCUMENTS AND UTILIZE

ALL AVAILABLE AS-BUILT DRAWINGS FROM THE OWNER. TEST AND

BALANCE CONTRACTOR SHALL VISIT SITE PRIOR TO CONSTRUCTION

AND VERIFY ALL EXISTING EQUIPMENT AND DEVICES, AND DEVELOP

THEIR TEST AND BALANCE FORMS INCLUDING DRAWINGS SHOWING

EQUIPMENT LOCATIONS, AIR DISTRIBUTION DEVICE LOCATIONS AND

TAG NUMBERS. IF THERE ARE LOCATIONS WHERE THE DRAWINGS DO

NOT REFLECT FIELD CONDITIONS, THE TEST AND BALANCE

CONTRACTOR SHALL INCLUDE THE AIRFLOW READINGS ON THE FORMS

AND LOCATE THE EQUIPMENT AND/OR AIR DEVICE ON THE DRAWINGS.

REFER TO SPECIFICATION SECTION 23 05 93 FOR MORE INFORMATION.

D. ALL DATA OBTAINED VIA TESTING AND MEASURING SHALL BE UTILIZED

TO ESTABLISH NEW HVAC SYSTEM PERFORMANCE AND BALANCE DATA

FOR THE RENOVATION. DATA SHALL BE FORWARDED TO THE PROJECT

ENGINEER FOR REVIEW AND COMMENT PRIOR TO COMMENCING THE

DEMOLITION AND/OR NEW WORK ASSOCIATED WITH THE FACILITY

RENOVATION.

E. THE CONTRACTOR SHALL PATCH, PAINT AND RETURN TO MATCH EXISTING

CONDITIONS FOR ANY FLOOR, WALL, OR CEILING THAT WAS DISTURBED TO

COMPLETE THIS PROJECT.

F. ALL NEW THERMOSTATS ARE TO BE MOUNTED AT A HEIGHT OF 54” ABOVE

FINISHED FLOOR. VERIFY FINAL THERMOSTAT LOCATIONS WITH VA.

G. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTS AND

ELEVATIONS.

H. ALL PIPING PLACED WITHIN INTERSTITIAL AREA.

NOTE: NOT ALL KEYNOTES ARE

USED ON EACH SHEET

1" = 10'-0" F6

MECHANICAL PLAN - FIRST LEVEL AREA H

1 HR SMOKE BARRIER

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION:

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND

SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.

1 HR INCIDENTAL USE

4G-1124G-112

4G-1164G-116 4G-1154G-115

4H-1014H-101

C4-110C4-110

4H-1154H-115

4K-1024K-102

4K-1434K-143

4H-1084H-108

C4-114C4-114

4K-1424K-142 4K-142A4K-142A

4J-1014J-101

4H-108A4H-108A

4H-101A4H-101A

C4-139C4-139

C4-138C4-138

4J-1024J-1024J-1034J-1034J-1044J-104

4J-1054J-105

4J-1064J-106

4J-1074J-107

4J-1084J-108 4J-1094J-109

4J-1104J-110

4J-1114J-111

4J-1124J-1124J-1134J-113

4J-1144J-114

4J-1154J-115

4J-1164J-116

4J-1174J-117

4J-1184J-118

4J-1194J-119

4J-1204J-120

4J-1214J-121

4J-1224J-122

4J-1234J-123

4J-1244J-124

4J-1254J-125

4J-1264J-126

4J-1274J-127 4J-1284J-128

4J-1294J-129 4J-1304J-130

4J-1314J-131

4J-1324J-132

4J-102B4J-102B4J-103B4J-103B

4J-102A4J-102A4J-103A4J-103A

4J-104A4J-104A

4J-109A4J-109A4J-115A4J-115A4J-119A4J-119A

4J-120A4J-120A

4J-121A4J-121A

4J-121B4J-121B

4J-121C4J-121C

4J-121D4J-121D

4J-123A4J-123A

4J-125A4J-125A 4J-116A4J-116A

C-8C-8

4J-124A4J-124A 4J-126A4J-126A 4J-129A4J-129A 4J-130A4J-130A

4J-132A4J-132A

4H-1024H-102

4H-1034H-103

4H-1044H-104

4H-1054H-105

4H-1064H-106

4H-1074H-107

4H-1094H-109 4H-1104H-110

4H-1114H-111

4H-1134H-113

4H-101D4H-101D

4H-101C4H-101C

4H-101B4H-101B4H-101E4H-101E

C4-142C4-142

C4-141C4-141

C4-143C4-143

C4-144C4-144

C4-145C4-145

C4-146C4-146

C4-147C4-147

C4-148C4-148

C4-149C4-149

4J-122A4J-122A

4H-1124H-112

4P-1194P-119

4P-1204P-120

4P-1214P-121

4P-1224P-122

4P-1234P-123 4P-1244P-124

4J-1214J-121

4J-121C4J-121C on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

GENERAL NOTES

KEYNOTES

A

B D

TRUE NORTH

PLAN NORTH

E F

G

H

J

K

L

M

C

KEYPLANA/E:

TRIPLE C - The A/E Group

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

As indicated

B

IM

/6

-2

-7

E

H R

M I n fr a st ru ct u re

U p g ra d e s

M P

L S

V A

M C

/6 -2

-7

.M

E H

R M

.M E

P .B

.L

.r vt /6

/2

:2 :4

P

M

05/06/2022 M. Perkins G. Weaver

618-21-700

1383 - 70M-104J

MECHANICAL PLAN - FOURTH LEVEL AREA J

1 Veterans Drive, Minneapolis, MN 55417

B70

EHRM INFRASTRUCTURE

UPGRADESFINAL BID DOCUMENTS

1. PROVIDE PACKAGED NEW FAN COIL UNIT, CHILLED WATER PIPING,

CONDENSATE PIPING, THERMOSTAT AND BACNET CONTROLS MODULE

CONNECTED TO EXISTING CHILLED WATER SUPPLY/RETURN RISER. SEE RISER

DIAGRAMS FOR CONNECTIONS. LOCATE FAN COIL UNITS ABOVE DOOR.

PROVIDE DRAIN PAN WITH LEAK DETECTION CONNECTED TO BAS.

2. PROVIDE CONDENSATE PUMP, TO BE MOUNTED HIDDEN WITHIN THE INDOOR

UNIT, CAPABLE OF LIFTING UP 50 FEET WITH 8 FEET SUCTION AND 10 GPH

PUMPING CAPACITY. PROVIDE ELECTRICAL SERVICE FOR CONDENSATE PUMP

IF NOT FED FROM INDOOR UNIT. PROVIDE NEW CONDENSATE LINE FOR NEW

MECHANICAL EQUIPMENT, COORDINATE WITH VA. PROVIDE COORDINATION

DRAWINGS FOR EACH DRAIN LINE INSTALLATION PER 01 33 23 PRIOR TO

BEGINNING WORK.

3. PROVIDE NEW DEDICATED THERMOSTAT, COORDINATE FINAL LOCATION WITH

EXISTING AND NEW EQUIPMENT. THERMOSTATS SHALL BE DISPLAY ONLY WITH

CONTROLLABILITY THROUGH THE BMS.

4. PROVIDE BACNET CONTROLLER MOUNTED ADJACENT TO UNIT IN TR. CONNECT

WITH UTP CABLE TO EXISTING ETHERNET SWITCH IN LOCAL TR TO BE

ADDRESSABLE ON VA NETWORK/HVAC FMS.

5. PROVIDE NEW PUMPED CONDENSATE LINE, DROP DOWN ON WALL TO

DISCHARGE OVER EXISTING SINK BELOW, SECURE PIPING TO WALL. PIPE TO BE

CUT AT 45 DEGREE ANGLE AT OUTLET.

6. SEE ARCHITECTURAL DRAWINGS FOR CONTEXT.

7. PROVIDE ELECTRICAL CIRCUIT FOR EACH NEW CHILLED WATER FAN COIL UNIT.

SEE ELECTRICAL SHEETS.

8. EXISTING FACILITY HOUSE AIR THERMOSTAT TO REMAIN, PROTECT IN PLACE.

9. EXISTING CEILING MOUNTED SUPPLY AND RETURN AIR DEVICES TO REMAIN.

COORDINATE WITH REMOVAL OF EXISTING GYPSUM CEILING AND ALL OTHER

TRADES, RESUPPORT AIR DEVICE AS REQUIRED ABOVE CABLE TRAY AND

LIGHTING. SEE SHEET E-501 AND ARCHITECTURAL PLANS FOR ADDITIONAL

INFORMATION.

10. CONTRACTOR SHALL PROVIDE RATED PENETRATION TO MATCH WALL RATING

AT THIS LOCATION. SEE DETAILS ON M-500 SERIES SHEETS AND

SPECIFICATIONS FOR ADDITIONAL INFORMATION.

11. EXISTING PENETRATION TO REMAIN.

12. REBALANCE AIRFLOW AFTER CONSTRUCTION IS COMPLETE.

13. REMOVE RADIATORS AND CAP SERVICE LINES IN THE INTERSTITIAL SPACE.

14. CONNECT TO EXISTING CONDENSATE STACK.

A. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT, DUCTWORK AND PIPING

WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND SHALL

PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN

REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.

B. COORDINATE ALL DUCTWORK AND PIPE ROUTING AND ELEVATIONS WITH

OTHER TRADES IN ADVANCE OF INSTALLATION.

C. TEST AND BALANCE CONTRACTOR SHALL PROVIDE A PRE-

CONSTRUCTION TAB REPORT FOR THE EQUIPMENT AND ASSOCIATED

SYSTEMS SHOWN ON THE CONSTRUCTION DOCUMENTS AND UTILIZE

ALL AVAILABLE AS-BUILT DRAWINGS FROM THE OWNER. TEST AND

BALANCE CONTRACTOR SHALL VISIT SITE PRIOR TO CONSTRUCTION

AND VERIFY ALL EXISTING EQUIPMENT AND DEVICES, AND DEVELOP

THEIR TEST AND BALANCE FORMS INCLUDING DRAWINGS SHOWING

EQUIPMENT LOCATIONS, AIR DISTRIBUTION DEVICE LOCATIONS AND

TAG NUMBERS. IF THERE ARE LOCATIONS WHERE THE DRAWINGS DO

NOT REFLECT FIELD CONDITIONS, THE TEST AND BALANCE

CONTRACTOR SHALL INCLUDE THE AIRFLOW READINGS ON THE FORMS

AND LOCATE THE EQUIPMENT AND/OR AIR DEVICE ON THE DRAWINGS.

REFER TO SPECIFICATION SECTION 23 05 93 FOR MORE INFORMATION.

D. ALL DATA OBTAINED VIA TESTING AND MEASURING SHALL BE UTILIZED

TO ESTABLISH NEW HVAC SYSTEM PERFORMANCE AND BALANCE DATA

FOR THE RENOVATION. DATA SHALL BE FORWARDED TO THE PROJECT

ENGINEER FOR REVIEW AND COMMENT PRIOR TO COMMENCING THE

DEMOLITION AND/OR NEW WORK ASSOCIATED WITH THE FACILITY

RENOVATION.

E. THE CONTRACTOR SHALL PATCH, PAINT AND RETURN TO MATCH EXISTING

CONDITIONS FOR ANY FLOOR, WALL, OR CEILING THAT WAS DISTURBED TO

COMPLETE THIS PROJECT.

F. ALL NEW THERMOSTATS ARE TO BE MOUNTED AT A HEIGHT OF 54” ABOVE

FINISHED FLOOR. VERIFY FINAL THERMOSTAT LOCATIONS WITH VA.

G. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTS AND

ELEVATIONS.

H. ALL PIPING PLACED WITHIN INTERSTITIAL AREA.

NOTE: NOT ALL KEYNOTES ARE

USED ON EACH SHEET

SCALE: 1" = 10'-0"

F2

MECHANICAL PLAN - FIRST LEVEL

AREA J

1 HR SMOKE BARRIER

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION:

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND

SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.

1 HR INCIDENTAL USE

C4-100C4-100

4H-1014H-101

C4-100C4-100

4J-1234J-123

4J-1244J-124 4J-1264J-126 4J-1294J-129 4J-1304J-130

4J-1324J-132

4J-121D4J-121D

4H-101D4H-101D

C4-149C4-149

4J-122A4J-122A

4P-1194P-119

4P-1204P-120

4P-1214P-121

4P-1224P-122

4P-1234P-123 4P-1244P-124

C4-152C4-152

C4-150C4-150

4P-1084P-108

4P-1094P-109

4P-1104P-110

4P-1114P-111

4P-1124P-112 4P-1134P-113

4P-1144P-1144P-1154P-115

4P-1164P-116

4P-1174P-117

4P-1184P-118

4P-1254P-125

4P-1264P-1264P-1274P-127

4P-1284P-128

4P-1294P-129

4P-1304P-130

4P-1314P-131

4P-1324P-132

4P-1074P-107

C4-151C4-151

C4-100C4-100

4P-1324P-132

C4-152C4-152

C4-150C4-150

1" CD

on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

GENERAL NOTES

KEYNOTES

A

B D

TRUE NORTH

PLAN NORTH

E F

G

H

J

K

L

M

C

KEYPLANA/E:

TRIPLE C - The A/E Group

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

As indicated

B

IM

/6

-2

-7

E

H R

M I n fr a st ru ct u re

U p g ra d e s

M P

L S

V A

M C

/6 -2

-7

.M

E H

R M

.M E

P .B

.L

.r vt /6

/2

:2 :5

P

M

05/06/2022 M. Perkins G. Weaver

618-21-700

1383 - 70M-104K

MECHANICAL PLAN - FOURTH LEVEL AREA K

1 Veterans Drive, Minneapolis, MN 55417

B70

EHRM INFRASTRUCTURE

UPGRADESFINAL BID DOCUMENTS

1. PROVIDE PACKAGED NEW FAN COIL UNIT, CHILLED WATER PIPING,

CONDENSATE PIPING, THERMOSTAT AND BACNET CONTROLS MODULE

CONNECTED TO EXISTING CHILLED WATER SUPPLY/RETURN RISER. SEE RISER

DIAGRAMS FOR CONNECTIONS. LOCATE FAN COIL UNITS ABOVE DOOR.

PROVIDE DRAIN PAN WITH LEAK DETECTION CONNECTED TO BAS.

2. PROVIDE CONDENSATE PUMP, TO BE MOUNTED HIDDEN WITHIN THE INDOOR

UNIT, CAPABLE OF LIFTING UP 50 FEET WITH 8 FEET SUCTION AND 10 GPH

PUMPING CAPACITY. PROVIDE ELECTRICAL SERVICE FOR CONDENSATE PUMP

IF NOT FED FROM INDOOR UNIT. PROVIDE NEW CONDENSATE LINE FOR NEW

MECHANICAL EQUIPMENT, COORDINATE WITH VA. PROVIDE COORDINATION

DRAWINGS FOR EACH DRAIN LINE INSTALLATION PER 01 33 23 PRIOR TO

BEGINNING WORK.

3. PROVIDE NEW DEDICATED THERMOSTAT, COORDINATE FINAL LOCATION WITH

EXISTING AND NEW EQUIPMENT. THERMOSTATS SHALL BE DISPLAY ONLY WITH

CONTROLLABILITY THROUGH THE BMS.

4. PROVIDE BACNET CONTROLLER MOUNTED ADJACENT TO UNIT IN TR. CONNECT

WITH UTP CABLE TO EXISTING ETHERNET SWITCH IN LOCAL TR TO BE

ADDRESSABLE ON VA NETWORK/HVAC FMS.

5. PROVIDE NEW PUMPED CONDENSATE LINE, DROP DOWN ON WALL TO

DISCHARGE OVER EXISTING SINK BELOW, SECURE PIPING TO WALL. PIPE TO BE

CUT AT 45 DEGREE ANGLE AT OUTLET.

6. SEE ARCHITECTURAL DRAWINGS FOR CONTEXT.

7. PROVIDE ELECTRICAL CIRCUIT FOR EACH NEW CHILLED WATER FAN COIL UNIT.

SEE ELECTRICAL SHEETS.

8. EXISTING FACILITY HOUSE AIR THERMOSTAT TO REMAIN, PROTECT IN PLACE.

9. EXISTING CEILING MOUNTED SUPPLY AND RETURN AIR DEVICES TO REMAIN.

COORDINATE WITH REMOVAL OF EXISTING GYPSUM CEILING AND ALL OTHER

TRADES, RESUPPORT AIR DEVICE AS REQUIRED ABOVE CABLE TRAY AND

LIGHTING. SEE SHEET E-501 AND ARCHITECTURAL PLANS FOR ADDITIONAL

INFORMATION.

10. CONTRACTOR SHALL PROVIDE RATED PENETRATION TO MATCH WALL RATING

AT THIS LOCATION. SEE DETAILS ON M-500 SERIES SHEETS AND

SPECIFICATIONS FOR ADDITIONAL INFORMATION.

11. EXISTING PENETRATION TO REMAIN.

12. REBALANCE AIRFLOW AFTER CONSTRUCTION IS COMPLETE.

13. REMOVE RADIATORS AND CAP SERVICE LINES IN THE INTERSTITIAL SPACE.

14. CONNECT TO EXISTING CONDENSATE STACK.

A. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT, DUCTWORK AND PIPING

WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND SHALL

PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN

REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.

B. COORDINATE ALL DUCTWORK AND PIPE ROUTING AND ELEVATIONS WITH

OTHER TRADES IN ADVANCE OF INSTALLATION.

C. TEST AND BALANCE CONTRACTOR SHALL PROVIDE A PRE-

CONSTRUCTION TAB REPORT FOR THE EQUIPMENT AND ASSOCIATED

SYSTEMS SHOWN ON THE CONSTRUCTION DOCUMENTS AND UTILIZE

ALL AVAILABLE AS-BUILT DRAWINGS FROM THE OWNER. TEST AND

BALANCE CONTRACTOR SHALL VISIT SITE PRIOR TO CONSTRUCTION

AND VERIFY ALL EXISTING EQUIPMENT AND DEVICES, AND DEVELOP

THEIR TEST AND BALANCE FORMS INCLUDING DRAWINGS SHOWING

EQUIPMENT LOCATIONS, AIR DISTRIBUTION DEVICE LOCATIONS AND

TAG NUMBERS. IF THERE ARE LOCATIONS WHERE THE DRAWINGS DO

NOT REFLECT FIELD CONDITIONS, THE TEST AND BALANCE

CONTRACTOR SHALL INCLUDE THE AIRFLOW READINGS ON THE FORMS

AND LOCATE THE EQUIPMENT AND/OR AIR DEVICE ON THE DRAWINGS.

REFER TO SPECIFICATION SECTION 23 05 93 FOR MORE INFORMATION.

D. ALL DATA OBTAINED VIA TESTING AND MEASURING SHALL BE UTILIZED

TO ESTABLISH NEW HVAC SYSTEM PERFORMANCE AND BALANCE DATA

FOR THE RENOVATION. DATA SHALL BE FORWARDED TO THE PROJECT

ENGINEER FOR REVIEW AND COMMENT PRIOR TO COMMENCING THE

DEMOLITION AND/OR NEW WORK ASSOCIATED WITH THE FACILITY

RENOVATION.

E. THE CONTRACTOR SHALL PATCH, PAINT AND RETURN TO MATCH EXISTING

CONDITIONS FOR ANY FLOOR, WALL, OR CEILING THAT WAS DISTURBED TO

COMPLETE THIS PROJECT.

F. ALL NEW THERMOSTATS ARE TO BE MOUNTED AT A HEIGHT OF 54” ABOVE

FINISHED FLOOR. VERIFY FINAL THERMOSTAT LOCATIONS WITH VA.

G. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTS AND

ELEVATIONS.

H. ALL PIPING PLACED WITHIN INTERSTITIAL AREA.

NOTE: NOT ALL KEYNOTES ARE

USED ON EACH SHEET

SCALE: 1" = 10'-0"

F3

MECHANICAL PLAN - FIRST LEVEL

AREA K

1 HR SMOKE BARRIER

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION:

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND

SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.

1 HR INCIDENTAL USE

4M-101

4M-104

TELECOM ROOM

4M-106

ELECTRICAL ROOM

4M-107

C4-177

4P-133

C4-154

4P-101

4P-102

TELECOM ROOM

4P-103

4P-101A

4N-101

4N-1024N-1034N-104

4N-1054N-106

TELECOM ROOM

4N-107

ELECTRICAL ROOM

4N-108

F

G

4S-8

4S-10

4M-102

4M-103

4M-108

4M-1104M-1114M-1124M-1134M-1144M-115 4M-1164M-117

4M-119

4M-120

4M-121

4M-122

4M-125

4M-126

4M-131

4M-132

4M-133

4M-134

4M-135

4M-122A

4M-109B

4M-109C

4M-115A

4S-7

4Q-101

4Q-102

4Q-103

4Q-104

4Q-105

4Q-106

4Q-107

4Q-108

4Q-109

4Q-111 4Q-112 4Q-123

4Q-124

4Q-125

4Q-126

4Q-127

C4-173

C4-174A

C4-156

C4-165

C4-157

C4-158

C4-166

4M-118

4M-109

4M-109A

C4-164

C4-159 C4-163C4-159 C4-163

70M-441 C5

70M-441 C2

1 1/2" CHWR

1 1/2" CHWS

3/4" CD

1" CDPIPE RISER

PIPE RISER

1 1/2" CHWS

1 1/2" CHWR

on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

GENERAL NOTES

KEYNOTES

A

B D

TRUE NORTH

PLAN NORTH

E F

G

H

J

K

L

M

C

KEYPLANA/E:

TRIPLE C - The A/E Group

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

As indicated

B

IM

/6

-2

-7

E

H R

M I n fr a st ru ct u re

U p g ra d e s

M P

L S

V A

M C

/6 -2

-7

.M

E H

R M

.M E

P .B

.L

.r vt /6

/2

:2 :1

P

M

05/06/2022 M. Perkins G. Weaver

618-21-700

1383 - 70M-104L

MECHANICAL PLAN - FOURTH LEVEL AREA L

1 Veterans Drive, Minneapolis, MN 55417

B70

EHRM INFRASTRUCTURE

UPGRADESFINAL BID DOCUMENTS

1. PROVIDE PACKAGED NEW FAN COIL UNIT, CHILLED WATER PIPING,

CONDENSATE PIPING, THERMOSTAT AND BACNET CONTROLS MODULE

CONNECTED TO EXISTING CHILLED WATER SUPPLY/RETURN RISER. SEE RISER

DIAGRAMS FOR CONNECTIONS. LOCATE FAN COIL UNITS ABOVE DOOR.

PROVIDE DRAIN PAN WITH LEAK DETECTION CONNECTED TO BAS.

2. PROVIDE CONDENSATE PUMP, TO BE MOUNTED HIDDEN WITHIN THE INDOOR

UNIT, CAPABLE OF LIFTING UP 50 FEET WITH 8 FEET SUCTION AND 10 GPH

PUMPING CAPACITY. PROVIDE ELECTRICAL SERVICE FOR CONDENSATE PUMP

IF NOT FED FROM INDOOR UNIT. PROVIDE NEW CONDENSATE LINE FOR NEW

MECHANICAL EQUIPMENT, COORDINATE WITH VA. PROVIDE COORDINATION

DRAWINGS FOR EACH DRAIN LINE INSTALLATION PER 01 33 23 PRIOR TO

BEGINNING WORK.

3. PROVIDE NEW DEDICATED THERMOSTAT, COORDINATE FINAL LOCATION WITH

EXISTING AND NEW EQUIPMENT. THERMOSTATS SHALL BE DISPLAY ONLY WITH

CONTROLLABILITY THROUGH THE BMS.

4. PROVIDE BACNET CONTROLLER MOUNTED ADJACENT TO UNIT IN TR. CONNECT

WITH UTP CABLE TO EXISTING ETHERNET SWITCH IN LOCAL TR TO BE

ADDRESSABLE ON VA NETWORK/HVAC FMS.

5. PROVIDE NEW PUMPED CONDENSATE LINE, DROP DOWN ON WALL TO

DISCHARGE OVER EXISTING SINK BELOW, SECURE PIPING TO WALL. PIPE TO BE

CUT AT 45 DEGREE ANGLE AT OUTLET.

6. SEE ARCHITECTURAL DRAWINGS FOR CONTEXT.

7. PROVIDE ELECTRICAL CIRCUIT FOR EACH NEW CHILLED WATER FAN COIL UNIT.

SEE ELECTRICAL SHEETS.

8. EXISTING FACILITY HOUSE AIR THERMOSTAT TO REMAIN, PROTECT IN PLACE.

9. EXISTING CEILING MOUNTED SUPPLY AND RETURN AIR DEVICES TO REMAIN.

COORDINATE WITH REMOVAL OF EXISTING GYPSUM CEILING AND ALL OTHER

TRADES, RESUPPORT AIR DEVICE AS REQUIRED ABOVE CABLE TRAY AND

LIGHTING. SEE SHEET E-501 AND ARCHITECTURAL PLANS FOR ADDITIONAL

INFORMATION.

10. CONTRACTOR SHALL PROVIDE RATED PENETRATION TO MATCH WALL RATING

AT THIS LOCATION. SEE DETAILS ON M-500 SERIES SHEETS AND

SPECIFICATIONS FOR ADDITIONAL INFORMATION.

11. EXISTING PENETRATION TO REMAIN.

12. REBALANCE AIRFLOW AFTER CONSTRUCTION IS COMPLETE.

13. REMOVE RADIATORS AND CAP SERVICE LINES IN THE INTERSTITIAL SPACE.

14. CONNECT TO EXISTING CONDENSATE STACK.

A. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT, DUCTWORK AND PIPING

WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND SHALL

PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN

REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.

B. COORDINATE ALL DUCTWORK AND PIPE ROUTING AND ELEVATIONS WITH

OTHER TRADES IN ADVANCE OF INSTALLATION.

C. TEST AND BALANCE CONTRACTOR SHALL PROVIDE A PRE-

CONSTRUCTION TAB REPORT FOR THE EQUIPMENT AND ASSOCIATED

SYSTEMS SHOWN ON THE CONSTRUCTION DOCUMENTS AND UTILIZE

ALL AVAILABLE AS-BUILT DRAWINGS FROM THE OWNER. TEST AND

BALANCE CONTRACTOR SHALL VISIT SITE PRIOR TO CONSTRUCTION

AND VERIFY ALL EXISTING EQUIPMENT AND DEVICES, AND DEVELOP

THEIR TEST AND BALANCE FORMS INCLUDING DRAWINGS SHOWING

EQUIPMENT LOCATIONS, AIR DISTRIBUTION DEVICE LOCATIONS AND

TAG NUMBERS. IF THERE ARE LOCATIONS WHERE THE DRAWINGS DO

NOT REFLECT FIELD CONDITIONS, THE TEST AND BALANCE

CONTRACTOR SHALL INCLUDE THE AIRFLOW READINGS ON THE FORMS

AND LOCATE THE EQUIPMENT AND/OR AIR DEVICE ON THE DRAWINGS.

REFER TO SPECIFICATION SECTION 23 05 93 FOR MORE INFORMATION.

D. ALL DATA OBTAINED VIA TESTING AND MEASURING SHALL BE UTILIZED

TO ESTABLISH NEW HVAC SYSTEM PERFORMANCE AND BALANCE DATA

FOR THE RENOVATION. DATA SHALL BE FORWARDED TO THE PROJECT

ENGINEER FOR REVIEW AND COMMENT PRIOR TO COMMENCING THE

DEMOLITION AND/OR NEW WORK ASSOCIATED WITH THE FACILITY

RENOVATION.

E. THE CONTRACTOR SHALL PATCH, PAINT AND RETURN TO MATCH EXISTING

CONDITIONS FOR ANY FLOOR, WALL, OR CEILING THAT WAS DISTURBED TO

COMPLETE THIS PROJECT.

F. ALL NEW THERMOSTATS ARE TO BE MOUNTED AT A HEIGHT OF 54” ABOVE

FINISHED FLOOR. VERIFY FINAL THERMOSTAT LOCATIONS WITH VA.

G. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTS AND

ELEVATIONS.

H. ALL PIPING PLACED WITHIN INTERSTITIAL AREA.

NOTE: NOT ALL KEYNOTES ARE

USED ON EACH SHEET

1" = 10'-0" F3

MECHANICAL PLAN - FIRST LEVEL AREA L

1 HR SMOKE BARRIER

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION:

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND

SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.

1 HR INCIDENTAL USE

70M-443 C6

C4-19C4-19

C4-20C4-20

4T-1034T-103

C4-20C4-20

4S-1174S-117

C4-163C4-163

4Q-118E4Q-118E

4S-1084S-108

4S-1094S-109

4S-1104S-110

4S-1114S-111

4S-1124S-112

4S-1134S-113

4S-1144S-114

4S-1154S-115

4S-1164S-116

4Q-1174Q-117

4Q-1184Q-118

4Q-1194Q-1194Q-1204Q-120

4Q-118A4Q-118A 4Q-118B4Q-118B

4Q-118C4Q-118C

4Q-118D4Q-118D

4V-1014V-101

4V-1024V-102

4V-1034V-1034V-1044V-104

4V-1054V-105

4V-1064V-106

4V-1084V-108

4V-1094V-109

4V-1104V-110

4V-1114V-111

4V-1124V-112

4V-1134V-113

4V-1144V-114 4V-107B4V-107B

4V-100A4V-100A

4T-1064T-106

4T-1074T-107

4T-1084T-108

4T-1094T-109

4T-1104T-110

4T-1114T-111

4T-1124T-112

4T-1134T-113 4T-1144T-114

4T-114A4T-114A

4S-14S-1

4T-1044T-104

4V-1074V-107

4V-107A4V-107A

C4-186C4-186

C4-161C4-161

C4-194C4-194

C4-193C4-193

C4-190C4-190

C4-191C4-191

C4-192C4-192C4-195C4-195

4V-1004V-100

C4-187C4-187

4T-113A4T-113A

C4-136C4-136

70M-443 C3

1 1/2" CHWR

1 1/2" CHWS

1 1/2" CHWR

1 1/2" CHWS

1" CD

on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

GENERAL NOTES

KEYNOTES

A

B D

TRUE NORTH

PLAN NORTH

E F

G

H

J

K

L

M

C

KEYPLANA/E:

TRIPLE C - The A/E Group

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

As indicated

B

IM

/6

-2

-7

E

H R

M I n fr a st ru ct u re

U p g ra d e s

M P

L S

V A

M C

/6 -2

-7

.M

E H

R M

.M E

P .B

.L

.r vt /6

/2

:2 :2

P

M

05/06/2022 M. Perkins G. Weaver

618-21-700

1383 - 70M-104M

MECHANICAL PLAN - FOURTH LEVEL AREA M

1 Veterans Drive, Minneapolis, MN 55417

B70

EHRM INFRASTRUCTURE

UPGRADESFINAL BID DOCUMENTS

1. PROVIDE PACKAGED NEW FAN COIL UNIT, CHILLED WATER PIPING,

CONDENSATE PIPING, THERMOSTAT AND BACNET CONTROLS MODULE

CONNECTED TO EXISTING CHILLED WATER SUPPLY/RETURN RISER. SEE RISER

DIAGRAMS FOR CONNECTIONS. LOCATE FAN COIL UNITS ABOVE DOOR.

PROVIDE DRAIN PAN WITH LEAK DETECTION CONNECTED TO BAS.

2. PROVIDE CONDENSATE PUMP, TO BE MOUNTED HIDDEN WITHIN THE INDOOR

UNIT, CAPABLE OF LIFTING UP 50 FEET WITH 8 FEET SUCTION AND 10 GPH

PUMPING CAPACITY. PROVIDE ELECTRICAL SERVICE FOR CONDENSATE PUMP

IF NOT FED FROM INDOOR UNIT. PROVIDE NEW CONDENSATE LINE FOR NEW

MECHANICAL EQUIPMENT, COORDINATE WITH VA. PROVIDE COORDINATION

DRAWINGS FOR EACH DRAIN LINE INSTALLATION PER 01 33 23 PRIOR TO

BEGINNING WORK.

3. PROVIDE NEW DEDICATED THERMOSTAT, COORDINATE FINAL LOCATION WITH

EXISTING AND NEW EQUIPMENT. THERMOSTATS SHALL BE DISPLAY ONLY WITH

CONTROLLABILITY THROUGH THE BMS.

4. PROVIDE BACNET CONTROLLER MOUNTED ADJACENT TO UNIT IN TR. CONNECT

WITH UTP CABLE TO EXISTING ETHERNET SWITCH IN LOCAL TR TO BE

ADDRESSABLE ON VA NETWORK/HVAC FMS.

5. PROVIDE NEW PUMPED CONDENSATE LINE, DROP DOWN ON WALL TO

DISCHARGE OVER EXISTING SINK BELOW, SECURE PIPING TO WALL. PIPE TO BE

CUT AT 45 DEGREE ANGLE AT OUTLET.

6. SEE ARCHITECTURAL DRAWINGS FOR CONTEXT.

7. PROVIDE ELECTRICAL CIRCUIT FOR EACH NEW CHILLED WATER FAN COIL UNIT.

SEE ELECTRICAL SHEETS.

8. EXISTING FACILITY HOUSE AIR THERMOSTAT TO REMAIN, PROTECT IN PLACE.

9. EXISTING CEILING MOUNTED SUPPLY AND RETURN AIR DEVICES TO REMAIN.

COORDINATE WITH REMOVAL OF EXISTING GYPSUM CEILING AND ALL OTHER

TRADES, RESUPPORT AIR DEVICE AS REQUIRED ABOVE CABLE TRAY AND

LIGHTING. SEE SHEET E-501 AND ARCHITECTURAL PLANS FOR ADDITIONAL

INFORMATION.

10. CONTRACTOR SHALL PROVIDE RATED PENETRATION TO MATCH WALL RATING

AT THIS LOCATION. SEE DETAILS ON M-500 SERIES SHEETS AND

SPECIFICATIONS FOR ADDITIONAL INFORMATION.

11. EXISTING PENETRATION TO REMAIN.

12. REBALANCE AIRFLOW AFTER CONSTRUCTION IS COMPLETE.

13. REMOVE RADIATORS AND CAP SERVICE LINES IN THE INTERSTITIAL SPACE.

14. CONNECT TO EXISTING CONDENSATE STACK.

A. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT, DUCTWORK AND PIPING

WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND SHALL

PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN

REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.

B. COORDINATE ALL DUCTWORK AND PIPE ROUTING AND ELEVATIONS WITH

OTHER TRADES IN ADVANCE OF INSTALLATION.

C. TEST AND BALANCE CONTRACTOR SHALL PROVIDE A PRE-

CONSTRUCTION TAB REPORT FOR THE EQUIPMENT AND ASSOCIATED

SYSTEMS SHOWN ON THE CONSTRUCTION DOCUMENTS AND UTILIZE

ALL AVAILABLE AS-BUILT DRAWINGS FROM THE OWNER. TEST AND

BALANCE CONTRACTOR SHALL VISIT SITE PRIOR TO CONSTRUCTION

AND VERIFY ALL EXISTING EQUIPMENT AND DEVICES, AND DEVELOP

THEIR TEST AND BALANCE FORMS INCLUDING DRAWINGS SHOWING

EQUIPMENT LOCATIONS, AIR DISTRIBUTION DEVICE LOCATIONS AND

TAG NUMBERS. IF THERE ARE LOCATIONS WHERE THE DRAWINGS DO

NOT REFLECT FIELD CONDITIONS, THE TEST AND BALANCE

CONTRACTOR SHALL INCLUDE THE AIRFLOW READINGS ON THE FORMS

AND LOCATE THE EQUIPMENT AND/OR AIR DEVICE ON THE DRAWINGS.

REFER TO SPECIFICATION SECTION 23 05 93 FOR MORE INFORMATION.

D. ALL DATA OBTAINED VIA TESTING AND MEASURING SHALL BE UTILIZED

TO ESTABLISH NEW HVAC SYSTEM PERFORMANCE AND BALANCE DATA

FOR THE RENOVATION. DATA SHALL BE FORWARDED TO THE PROJECT

ENGINEER FOR REVIEW AND COMMENT PRIOR TO COMMENCING THE

DEMOLITION AND/OR NEW WORK ASSOCIATED WITH THE FACILITY

RENOVATION.

E. THE CONTRACTOR SHALL PATCH, PAINT AND RETURN TO MATCH EXISTING

CONDITIONS FOR ANY FLOOR, WALL, OR CEILING THAT WAS DISTURBED TO

COMPLETE THIS PROJECT.

F. ALL NEW THERMOSTATS ARE TO BE MOUNTED AT A HEIGHT OF 54” ABOVE

FINISHED FLOOR. VERIFY FINAL THERMOSTAT LOCATIONS WITH VA.

G. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTS AND

ELEVATIONS.

H. ALL PIPING PLACED WITHIN INTERSTITIAL AREA.

NOTE: NOT ALL KEYNOTES ARE

USED ON EACH SHEET

1" = 10'-0" F3

MECHANICAL PLAN - FIRST LEVEL AREA M

1 HR SMOKE BARRIER

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION:

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND

SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.

1 HR INCIDENTAL USE

70M-105

F1

PIPE DROP

PIPE DROP

1" CD

Elec. Equip. Room

5K-107A 200.00

SF

FCU-5K-13

FCU-5K-14

TYP.

3/4" CD

1" CD

3/4" CD

6 9 12 on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

GENERAL NOTES

KEYNOTES

A/E:

TRIPLE C - The A/E Group

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

As indicated

B

IM

/6

-2

-7

E

H R

M I n fr a s tr u c tu re U p g ra d e s M

P L S

V A

M C

/6 -2

-7

.M

E H

R M

.M E

P .B

.L

.r v t

/6

/2

:2 :0

P

M

05/06/2022 M. Perkins G. Weaver

618-21-700

1383 - 70M-105

MECHANICAL PLAN - FIFTH LEVEL

1 Veterans Drive, Minneapolis, MN 55417

B70

EHRM INFRASTRUCTURE

UPGRADESFINAL BID DOCUMENTS

1. PROVIDE PACKAGED NEW FAN COIL UNIT, CHILLED WATER PIPING,

CONDENSATE PIPING, THERMOSTAT AND BACNET CONTROLS MODULE

CONNECTED TO EXISTING CHILLED WATER SUPPLY/RETURN RISER. SEE RISER

DIAGRAMS FOR CONNECTIONS. LOCATE FAN COIL UNITS ABOVE DOOR.

PROVIDE DRAIN PAN WITH LEAK DETECTION CONNECTED TO BAS.

2. PROVIDE CONDENSATE PUMP, TO BE MOUNTED HIDDEN WITHIN THE INDOOR

UNIT, CAPABLE OF LIFTING UP 50 FEET WITH 8 FEET SUCTION AND 10 GPH

PUMPING CAPACITY. PROVIDE ELECTRICAL SERVICE FOR CONDENSATE PUMP

IF NOT FED FROM INDOOR UNIT. PROVIDE NEW CONDENSATE LINE FOR NEW

MECHANICAL EQUIPMENT, COORDINATE WITH VA. PROVIDE COORDINATION

DRAWINGS FOR EACH DRAIN LINE INSTALLATION PER 01 33 23 PRIOR TO

BEGINNING WORK.

3. PROVIDE NEW DEDICATED THERMOSTAT, COORDINATE FINAL LOCATION WITH

EXISTING AND NEW EQUIPMENT. THERMOSTATS SHALL BE DISPLAY ONLY WITH

CONTROLLABILITY THROUGH THE BMS.

4. PROVIDE BACNET CONTROLLER MOUNTED ADJACENT TO UNIT IN TR. CONNECT

WITH UTP CABLE TO EXISTING ETHERNET SWITCH IN LOCAL TR TO BE

ADDRESSABLE ON VA NETWORK/HVAC FMS.

5. PROVIDE NEW PUMPED CONDENSATE LINE, DROP DOWN ON WALL TO

DISCHARGE OVER EXISTING SINK BELOW, SECURE PIPING TO WALL. PIPE TO BE

CUT AT 45 DEGREE ANGLE AT OUTLET.

6. SEE ARCHITECTURAL DRAWINGS FOR CONTEXT.

7. PROVIDE ELECTRICAL CIRCUIT FOR EACH NEW CHILLED WATER FAN COIL UNIT.

SEE ELECTRICAL SHEETS.

8. EXISTING FACILITY HOUSE AIR THERMOSTAT TO REMAIN, PROTECT IN PLACE.

9. EXISTING CEILING MOUNTED SUPPLY AND RETURN AIR DEVICES TO REMAIN.

COORDINATE WITH REMOVAL OF EXISTING GYPSUM CEILING AND ALL OTHER

TRADES, RESUPPORT AIR DEVICE AS REQUIRED ABOVE CABLE TRAY AND

LIGHTING. SEE SHEET E-501 AND ARCHITECTURAL PLANS FOR ADDITIONAL

INFORMATION.

10. CONTRACTOR SHALL PROVIDE RATED PENETRATION TO MATCH WALL RATING

AT THIS LOCATION. SEE DETAILS ON M-500 SERIES SHEETS AND

SPECIFICATIONS FOR ADDITIONAL INFORMATION.

11. EXISTING PENETRATION TO REMAIN.

12. REBALANCE AIRFLOW AFTER CONSTRUCTION IS COMPLETE.

13. REMOVE RADIATORS AND CAP SERVICE LINES IN THE INTERSTITIAL SPACE.

14. CONNECT TO EXISTING CONDENSATE STACK.

A. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT, DUCTWORK AND PIPING

WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND SHALL

PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN

REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.

B. COORDINATE ALL DUCTWORK AND PIPE ROUTING AND ELEVATIONS WITH

OTHER TRADES IN ADVANCE OF INSTALLATION.

C. TEST AND BALANCE CONTRACTOR SHALL PROVIDE A PRE-

CONSTRUCTION TAB REPORT FOR THE EQUIPMENT AND ASSOCIATED

SYSTEMS SHOWN ON THE CONSTRUCTION DOCUMENTS AND UTILIZE

ALL AVAILABLE AS-BUILT DRAWINGS FROM THE OWNER. TEST AND

BALANCE CONTRACTOR SHALL VISIT SITE PRIOR TO CONSTRUCTION

AND VERIFY ALL EXISTING EQUIPMENT AND DEVICES, AND DEVELOP

THEIR TEST AND BALANCE FORMS INCLUDING DRAWINGS SHOWING

EQUIPMENT LOCATIONS, AIR DISTRIBUTION DEVICE LOCATIONS AND

TAG NUMBERS. IF THERE ARE LOCATIONS WHERE THE DRAWINGS DO

NOT REFLECT FIELD CONDITIONS, THE TEST AND BALANCE

CONTRACTOR SHALL INCLUDE THE AIRFLOW READINGS ON THE FORMS

AND LOCATE THE EQUIPMENT AND/OR AIR DEVICE ON THE DRAWINGS.

REFER TO SPECIFICATION SECTION 23 05 93 FOR MORE INFORMATION.

D. ALL DATA OBTAINED VIA TESTING AND MEASURING SHALL BE UTILIZED

TO ESTABLISH NEW HVAC SYSTEM PERFORMANCE AND…

This is the start of the file's text. The full file is on GovTribe.