618-21-700.MEHRM.FINAL.B70.20220506Part-3.pdf
PDF 14 MB Posted
- Solicitation number
- 36C77622R0045
About this file
This document describes a federal contract opportunity for construction design and infrastructure upgrades at the Minneapolis VA Medical Center. The project involves building infrastructure to support the Electronic Health Record Modernization project, including constructing a new server room on the hospital roof. Work will take place throughout multiple departments and require coordination to minimize disruption. The solicitation will be a Request for Proposal evaluated according to FAR Parts 15, 19, and 36. It is set aside for Service-Disabled Veteran-Owned Small Businesses. The period of performance is approximately 450 calendar days with a magnitude of construction between $20-50 million. All questions must be submitted in writing by the specified date.
View the file
Other files
Show 40 more
Latest 50 of 80 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
70A-404A
B3
70A-404D
C3
70A-404G
B4
70A-404G
C4
70A-404L
F1
70A-404M
B4
AREA A
AREA B
AREA C
AREA D
AREA E
AREA F
AREA G
AREA H
AREA J
AREA K
AREA L
AREA M
SHEET SYMBOL LEGEND
KEYNOTES
GENERAL NOTES
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
NEW CONSTRUCTION, WITH PARTITION TYPE
A
A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT
REQUIREMENTS AND PROJECT LOCATION DRAWINGS.
B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES
INFORMATION.
C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
SYSTEMS INFORMATION.
D. NEW TELECOM ROOMS SHALL BE 1 HR FIRE AND SMOKE RATED AND
COMPLY WITH THE LATEST VA PHYSICAL SECURITY STANDARDS, AND
CAMPUS STANDARDS.
E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.
F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.
G. SEE TYPICAL CEILING DETAILS ON SHEET A-531
PARTITION RATING GRAPHICS:
2 HR FIRE SHAFT
1 HR SMOKE BARRIER
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION:
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND
SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.
1 HR INCIDENTAL USE
1 HR FIRE & SMOKE BARRIER
on e-ei gh th in ch o ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in es ne fo ot
REVISIONS DATE
General Notes:
GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO
THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED
BY THE VARIOUS SUBCONTRACTORS.
Approved: Division Chief
Issue Date Checked Drawn
DrawingNumber
Building Number
Project NumberDrawing Title Project Title
Location Drawing Scale
Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs
Office of Construction and Facilities Management
FULLY SPRINKLERED
Phase
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
TRUE NORTH
PLAN NORTH
KEYPLANA/E:
TRIPLE C - The A/E Group
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
A
B D
E F
G
H
J
K
L
M
C
As indicated
B
IM
/6
-2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e s
M P
L S
V A
M C
/6 -2
-7
.M
E H
R M
.A R
C H
.B .L
.r v t
/5
/2
:2 :3
A
M
05/06/2022 M. Perkins K. McDermott
618-21-700
1383 - 70A-104
OVERALL ARCHITECTURAL FLOOR PLAN -
FOURTH LEVEL
1 Veterans Drive, Minneapolis, MN 55417
B70
EHRM INFRASTRUCTURE
UPGRADESFINAL BID DOCUMENTS
1/32" = 1'-0" F2
OVERALL ARCHITECTURAL FLOOR PLAN - FOURTH LEVEL
DOOR AND FRAME SCHEDULE
IDENTIFICATION DIMENSIONS PANEL FRAME DETAIL
FIRE RATING
HARDWARE
NOTESLEVEL ROOM NO. ROOM NAME DOOR NO. W1 H T TYPE MATERIAL FINISH GLAZING UNDERCUT TYPE MATERIAL FINISH HEAD JAMB SILL GROUP ELECTRICAL
LEVEL 4 4C-102 TELECOM ROOM 4C-102 3' - 0" 7' - 0" 1 3/4" F WD WD NONE 3/8" 1 HM PTD E8/ 70A-100 E7/ 70A-100 45 MIN SH-HW-3F SEE ELECT & SPECS
LEVEL 4 4F-121E TELECOM ROOM 4F-121E 3' - 0" 7' - 0" 1 3/4" F WD WD NONE 3/8" 1 HM PTD E8/ 70A-100 E7/ 70A-100 45 MIN SH-HW-3F SEE ELECT & SPECS
LEVEL 4 4H-118 TELECOM ROOM 4H-118 3' - 0" 7' - 0" 1 3/4" F WD WD NONE 3/8" 1 HM PTD E8/ 70A-100 E7/ 70A-100 45 MIN SH-HW-3F SEE ELECT & SPECS
LEVEL 4 4P-103 TELECOM ROOM 4P-103 3' - 8" 6' - 6" 1 3/4" F WD WD NONE 3/8" 1 HM PTD E8/ 70A-100 E7/ 70A-100 45 MIN SH-HW-3F SEE ELECT & SPECS
LEVEL 4 4Q-118E TELECOM ROOM 4Q-118E 3' - 0" 7' - 0" 1 3/4" F WD WD NONE 3/8" 1 HM PTD E8/ 70A-100 E7/ 70A-100 45 MIN SH-HW-3F SEE ELECT & SPECS
LEVEL 4 4U-100A TELECOM ROOM 4U-100A 3' - 8" 7' - 0" 1 3/4" F WD WD NONE 3/8" 1 HM PTD E8/ 70A-100 E7/ 70A-100 45 MIN SH-HW-3F SEE ELECT & SPECS
NOT USED
/06
/20
SHEET SYMBOL LEGEND
KEYNOTES
GENERAL NOTES
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
NEW CONSTRUCTION, WITH PARTITION TYPE
A
A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT
REQUIREMENTS AND PROJECT LOCATION DRAWINGS.
B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES
INFORMATION.
C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
SYSTEMS INFORMATION.
D. NEW IT CLOSETS SHALL BE SMOKE RATED AND COMPLY WITH THE
LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS
STANDARDS.
E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.
F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.
G. SEE TYPICAL CEILING DETAILS ON SHEET A-531
PARTITION RATING GRAPHICS:
2 HR FIRE SHAFT
1 HR SMOKE BARRIER
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION:
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND
SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.
1 HR INCIDENTAL USE
1 HR FIRE & SMOKE BARRIER
HJKLMNPQRSTUV
BT-109BT-109
CB-3CB-3
BU-101BU-101BU-102BU-102
BU-103BU-103
BU-109BU-109
BU-110BU-110
BU-111BU-111 BU-112BU-112 BU-113BU-113 BU-114BU-114
CB-4ACB-4A
CB-1CB-1
CB-2CB-2
CB-4CB-4
CB-6CB-6
BU-116BU-116
BU-117BU-117
BU-118BU-118
BU-119BU-119BU-120BU-120
BU-121BU-121
BU-122BU-122 BU-123BU-123
CC
BU-110ABU-110A BU-110BBU-110B
BU-110CBU-110C BU-110DBU-110D
BU-110EBU-110E
BU-118ABU-118A
BU-118BBU-118B
BU-118CBU-118C
BU-118DBU-118D
BU-122ABU-122A
CB-10CB-10
CB-11CB-11
CB-13CB-13
CB-14CB-14
CB-15CB-15
BD-101BD-101
TELECOM
ROOM
BD-101ABD-101A
ELECTRICAL
ROOM
BD-101CBD-101C
TELECOM
ROOM
BD-101DBD-101D
TELECOM
ROOM
BD-101EBD-101E
ELECTRICAL
ROOM
BD-101FBD-101F
BD-101GBD-101G
BD-103BD-103
BB-128BB-128
BB-141BB-141BB-144BB-144
BB-146BB-146
M-5M-5
TELECOM
ROOM
BT-105BT-105
BT-107BT-107
BT-108BT-108
CB-3CB-3
TELECOM
ROOM
(GREEN-STACK)
BU-107A
ACTUAL: 195 SF
PROG: 170 SF
PRIMARY
BT-109BT-109
BU-101BU-101BU-102BU-102
BU-103BU-103
BU-105BU-105
BU-106BU-106
BU-107BU-107
BU-108BU-108
BU-109BU-109
BU-110BU-110
BU-111BU-111 BU-112BU-112 BU-113BU-113 BU-114BU-114
CB-4ACB-4A
CB-1CB-1
CB-2CB-2
CB-4CB-4
CB-6CB-6
BU-116BU-116
BU-117BU-117
BU-118BU-118
BU-119BU-119BU-120BU-120
BU-121BU-121
BU-122BU-122 BU-123BU-123
CC
BU-110ABU-110A BU-110BBU-110B
BU-110CBU-110C BU-110DBU-110D
BU-110EBU-110E
BU-118ABU-118A
BU-118BBU-118B
BU-118CBU-118C
BU-118DBU-118D
BU-122ABU-122A
CB-10CB-10
CB-11CB-11
CB-13CB-13
CB-14CB-14
CB-15CB-15
BD-101BD-101
ELECTRICAL
ROOM
BD-101BBD-101B
BD-101GBD-101G
BD-103BD-103
BB-128BB-128
BB-144BB-144BB-146BB-146
M-5M-5
BT-107BT-107
BT-108BT-108
70A-400A
B2
70A-400A
B4
BU-104BU-104
3'-4" 4"
'-1
1"
'-1
1"
TYP.
A 4 B
B
B
B
TELECOM
ROOM
(GREEN-STACK)
BU-107A
ACTUAL: 195 SF
PROG: 170 SF
PRIMARY
(EXT'G VIF)
17'-1 3/8"
'-7
B U
-1
A
BU-107BU-107
70A-100
D8
TYP ALL
TR WALLS
BU-104BU-104 BU-107BU-107
MEDICAL
SUPPLIES
BU-104BU-104
OPEN
OFFICE
BU-107BU-107
TELECOM
ROOM
(GREEN-STACK)
BU-107A
ACTUAL: 195 SF
PROG: 170 SF
PRIMARY
BU-107BU-107
on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot
REVISIONS DATE
General Notes:
GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO
THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED
BY THE VARIOUS SUBCONTRACTORS.
Approved: Division Chief
Issue Date Checked Drawn
DrawingNumber
Building Number
Project NumberDrawing Title Project Title
Location Drawing Scale
Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs
Office of Construction and Facilities Management
FULLY SPRINKLERED
Phase
NOT FOR CONSTRUCTION
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
TRUE NORTH
PLAN NORTH
KEYPLANA/E:
TRIPLE C - The A/E Group
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
A
B
D
F
G
H
J
K
L
M
N
As indicated
B
IM
/6
-2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e s M
P L S
V A
M C
/6 -2
-7
.M
E H
R M
.A R
C H
.B .L
.r v t
/5
/2
:1
:3
A
M
05/06/2022 M. Perkins K. McDermott
618-21-700
1383 - 70A-400A
ARCHITECTURAL ENLARGED VIEWS -
BASEMENT LEVEL AREA A
1 Veterans Drive, Minneapolis, MN 55417
B70
EHRM INFRASTRUCTURE
UPGRADESFINAL BID DOCUMENTS
1 REMOVE FLOORING AND WALL BASE IN AREA
2 TEMPORARY WALLS FOR ICRA ENCLOSURE. RE: ICRA REQUIREMENTS
3 REMOVE EXISTING DOOR AND FRAME. SEE DOOR SCHEDULE AND
SPECIFICATIONS FOR ADDITIONAL INFORMATION. MODIFY DOOR AS
REQUIRED FOR NEW ACCESS CONTROL HARDWARE. NEW DOOR TO
BE 45 MIN SMOKE RATED.
4 ALL WALLS TO BE 1 HR FIRE AND SMOKE-RATED. EXTEND TO DECK AS
NECESSARY. PATCH AND SEAL ALL PENETRATIONS AS NECESSARY.
5 REMOVE EXISTING ACOUSTICAL CEILING AND LIGHTS. MODIFY
AND/OR PROVIDE ADDITIONAL SUPPORTS AS REQUIRED FOR
EXISTING CEILING ITEMS TO REMAIN.
6 EXISTING ACOUSTICAL CEILING TO REMAIN. MODIFY AS NEEDED FOR
NEW WALLS.
7 TELECOM ROOM TO BE OPEN TO DECK ABOVE.
8 PROVIDE NEW FIRE EXTINGUISHER CABINET WITH A TYPE 2A:10B:C
CLEAN AGENT FIRE EXTINGUISHER LOCATED NO GREATER THAN 75
FEET AWAY FROM THE NEW TR. CONTRACTOR TO COORDINATE THE
NEW LOCATION WITH THE COR. CONTRACTOR SHALL BID A NEW FEC
FOR EACH TR IN THE SCOPE OF WORK. SEE SPECIFICATION 10 44 13.
9 PROVIDE TEMPORARY AIR TIGHT BARRIER AROUND WORK AREA
DURING ANY ACTIVITIES WHICH PRODUCE DUST. RE: ICRA
REQUIREMENTS
1" = 10'-0" F2
ARCHITECTURAL FLOOR PLAN - BASEMENT LEVEL AREA A
1/4" = 1'-0" B2
ARCHITECTURAL FLOOR PLAN - BASEMENT
LEVEL - ROOM BU-107 - DEMO
1/4" = 1'-0"
B4
ARCHITECTURAL FLOOR PLAN - BASEMENT
LEVEL - ROOM BU-107 - NEW
1/4" = 1'-0"
B6
ARCHITECTURAL RCP - BASEMENT LEVEL -
ROOM BU-107 - DEMO
1/4" = 1'-0"
B8
ARCHITECTURAL RCP - BASEMENT LEVEL -
ROOM BU-107 - NEW
/06
GENERAL NOTES
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
NEW CONSTRUCTION, WITH PARTITION TYPE
A
A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT
REQUIREMENTS AND PROJECT LOCATION DRAWINGS.
B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES
INFORMATION.
C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
SYSTEMS INFORMATION.
D. NEW IT CLOSETS SHALL BE SMOKE RATED AND COMPLY WITH THE
LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS
STANDARDS.
E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.
F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.
G. SEE TYPICAL CEILING DETAILS ON SHEET A-531
PARTITION RATING GRAPHICS:
2 HR FIRE SHAFT
1 HR SMOKE BARRIER
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION:
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND
SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.
1 HR INCIDENTAL USE
1 HR FIRE & SMOKE BARRIER
HJKLMNPQRSTUV
BD-135BD-135
BD-110BD-110BD-111BD-111
BD-112BD-112BD-113BD-113
BD-114BD-114
BD-115BD-115
BD-116BD-116
BD-117BD-117
BD-118BD-118
BD-119BD-119
BD-120BD-120
BD-121BD-121
BD-122BD-122BD-122ABD-122A
BD-120ABD-120A
BD-109BD-109
BD-123ABD-123A
BD-123BD-123
BD-124BD-124
BD-125BD-125BD-126BD-126BD-127BD-127
BD-128BD-128
BD-129BD-129 BD-130BD-130 BD-131BD-131
BD-132BD-132
BD-133BD-133
BD-134BD-134
BD-102BD-102
BD-103BD-103
BD-104BD-104
BD-105BD-105
BD-105ABD-105A
BD-106ABD-106A
BD-106BD-106
BD-107BD-107
BD-108BD-108
BD-110ABD-110A
BB-101BB-101 BB-102BB-102 BB-103BB-103 BB-104BB-104 BB-105BB-105 BB-106BB-106 BB-107BB-107 BB-108BB-108 BB-109BB-109
BB-110BB-110
BB-111BB-111
BB-112BB-112
BB-113BB-113
BB-114BB-114
BB-115BB-115
BB-116BB-116 BB-117BB-117
BB-118BB-118
BB-118ABB-118A
BB-121BB-121
BB-122BB-122
BB-123BB-123
BB-124BB-124
BB-125BB-125
BB-126BB-126
BB-127BB-127
BB-128BB-128
BB-129BB-129
BB-130BB-130
BB-131BB-131
BB-132BB-132
BB-133BB-133
BB-134BB-134
BB-135BB-135
BB-136BB-136
BB-137BB-137
BB-138BB-138
BB-139BB-139BB-140BB-140
BB-141BB-141
BB-142BB-142BB-143BB-143
BB-144BB-144
BB-145BB-145
BB-146BB-146
BB-147BB-147
BB-148BB-148BB-149BB-149
BB-150BB-150
BB-151BB-151
BB-152BB-152
ELECTRICAL
ROOM
BT-101BT-101
BA-113BA-113
BA-117BA-117
BA-117ABA-117A
BA-119BA-119 BA-119ABA-119A
CB-17CB-17 CB-17ACB-17A
CB-19CB-19
CB-20CB-20 CB-21CB-21
CB-22CB-22
CB-23CB-23
CB-23ACB-23A
CB-24CB-24
CB-25CB-25
CB-25ACB-25A
CB-26CB-26
CB-27CB-27
CB-28CB-28 CB-29CB-29
CB35BCB35B
CB32CB32
CB-52CB-52
BD-135BD-135
BD-110BD-110BD-111BD-111
BD-112BD-112BD-113BD-113
BD-114BD-114
BD-115BD-115
BD-116BD-116
BD-117BD-117
BD-118BD-118
BD-119BD-119
BD-120BD-120
BD-121BD-121
BD-122BD-122
BD-120ABD-120A
BD-109BD-109
BD-123ABD-123A
BD-123BD-123
BD-124BD-124
BD-125BD-125BD-126BD-126BD-127BD-127
BD-128BD-128
BD-129BD-129 BD-130BD-130 BD-131BD-131
BD-132BD-132
BD-133BD-133
BD-134BD-134
BD-102BD-102
BD-103BD-103
BD-104BD-104
BD-105BD-105
BD-105ABD-105A
BD-106ABD-106A
BD-106BD-106
BD-107BD-107
BD-108BD-108
BD-110ABD-110A
BB-101BB-101 BB-102BB-102 BB-103BB-103 BB-104BB-104 BB-105BB-105 BB-106BB-106 BB-107BB-107 BB-108BB-108 BB-109BB-109
BB-110BB-110
BB-111BB-111
BB-112BB-112
BB-113BB-113
BB-114BB-114
BB-115BB-115
BB-116BB-116 BB-117BB-117
BB-118BB-118
BB-118ABB-118A
BB-121BB-121
BB-122BB-122
BB-123BB-123
BB-124BB-124
BB-125BB-125
BB-126BB-126
BB-127BB-127
BB-128BB-128
BB-129BB-129
BB-130BB-130
BB-131BB-131
BB-132BB-132
BB-133BB-133
BB-134BB-134
BB-135BB-135
BB-136BB-136
BB-137BB-137
BB-138BB-138
BB-139BB-139BB-140BB-140
BB-141BB-141
BB-142BB-142BB-143BB-143
BB-144BB-144
BB-145BB-145
BB-146BB-146
BB-147BB-147
BB-148BB-148BB-149BB-149
BB-150BB-150
BB-151BB-151
BB-152BB-152
TELECOM
ROOM
BT-102BT-102
BA-113BA-113
BA-117BA-117
BA-117ABA-117A
BA-119BA-119 BA-119ABA-119A
CB-17CB-17 CB-17ACB-17A
CB-19CB-19
CB-20CB-20 CB-21CB-21
CB-22CB-22
CB-23CB-23
CB-23ACB-23A
CB-24CB-24
CB-25CB-25
CB-25ACB-25A
CB-26CB-26
CB-27CB-27
CB-28CB-28 CB-29CB-29
CB35BCB35B
CB32CB32
BH-111GBH-111G
on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot
REVISIONS DATE
General Notes:
GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO
THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED
BY THE VARIOUS SUBCONTRACTORS.
Approved: Division Chief
Issue Date Checked Drawn
DrawingNumber
Building Number
Project NumberDrawing Title Project Title
Location Drawing Scale
Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs
Office of Construction and Facilities Management
FULLY SPRINKLERED
Phase
NOT FOR CONSTRUCTION
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
TRUE NORTH
PLAN NORTH
KEYPLANA/E:
TRIPLE C - The A/E Group
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
A
B
D
F
G
H
J
K
L
M
N
As indicated
B
IM
/6
-2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e s M
P L S
V A
M C
/6 -2
-7
.M
E H
R M
.A R
C H
.B .L
.r v t
/5
/2
:1
:4
A
M
05/06/2022 M. Perkins K. McDermott
618-21-700
1383 - 70A-400B
ARCHITECTURAL ENLARGED VIEWS -
BASEMENT LEVEL AREA B
1 Veterans Drive, Minneapolis, MN 55417
B70
EHRM INFRASTRUCTURE
UPGRADESFINAL BID DOCUMENTS
1" = 10'-0" F2
ARCHITECTURAL FLOOR PLAN - BASEMENT LEVEL AREA B
NOT USED
/06
ABCDEFGH
CB35CB35
CB36CB36
CB36ACB36A
CB35BCB35B
TELECOM
ROOM
(CYAN-STACK)
CB35C
ACTUAL: 170 SF
PROG: 170 SF
PRIMARY
70A-400D
B3
70A-400D
B5
SHEET SYMBOL LEGEND
KEYNOTES
GENERAL NOTES
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
NEW CONSTRUCTION, WITH PARTITION TYPE
A
A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT
REQUIREMENTS AND PROJECT LOCATION DRAWINGS.
B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES
INFORMATION.
C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
SYSTEMS INFORMATION.
D. NEW IT CLOSETS SHALL BE SMOKE RATED AND COMPLY WITH THE
LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS
STANDARDS.
E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.
F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.
G. SEE TYPICAL CEILING DETAILS ON SHEET A-531
PARTITION RATING GRAPHICS:
2 HR FIRE SHAFT
1 HR SMOKE BARRIER
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION:
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND
SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.
1 HR INCIDENTAL USE
1 HR FIRE & SMOKE BARRIER
TELECOM
ROOM
(CYAN-STACK)
CB35C
ACTUAL: 170 SF
PROG: 170 SF
PRIMARY
B
B
A3
B
A 3 B
C B
C
ALIGN
'-6
/2
3 4
TELECOM
ROOM
(CYAN-STACK)
CB35CCB35C
CB35CB35
CB35CB35
HSS 12X3X1/4 HEADER
EXISTING WALL CONSTRUCTION
FIT NEW STRUCTURE TIGHT
TO EXISTING WALL
HSS 6X2X1/4 JAMBS
FLOOR FINISH
AT DOOR
THRESHOLD.
STEEL PLATE 12" X 3" X 1/2"
2X 1/2" DIAM. ADHESIVE ANCHORS
(HIT HY-200) INTO EXISTING
STRUCTURAL FLOOR.
1 1/2" 1 1/2"
1/
2" 9"
1/
2"
1/4"
HSS 6X2X1/4 JAMBS
A A
SECTION A: JAMB AND BASEPLATE DETAIL
EXISTING WALL
HSS 12X3X1/4 HEADER,
FIT TIGHT TO STRUCTURE
HSS 6X2X1/4 JAMB BEYOND
WALL BEYOND
EXISTING WALL
1/4"
3 SIDES
SECTION B: HEADER DETAIL
B on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot
REVISIONS DATE
General Notes:
GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO
THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED
BY THE VARIOUS SUBCONTRACTORS.
Approved: Division Chief
Issue Date Checked Drawn
DrawingNumber
Building Number
Project NumberDrawing Title Project Title
Location Drawing Scale
Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs
Office of Construction and Facilities Management
FULLY SPRINKLERED
Phase
NOT FOR CONSTRUCTION
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
TRUE NORTH
PLAN NORTH
KEYPLANA/E:
TRIPLE C - The A/E Group
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
A
B
D
F
G
H
J
K
L
M
N
As indicated
B
IM
/6
-2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e s M
P L S
V A
M C
/6 -2
-7
.M
E H
R M
.A R
C H
.B .L
.r v t
/5
/2
:1
:5
A
M
05/06/2022 M. Perkins K. McDermott
618-21-700
1383 - 70A-400D
ARCHITECTURAL ENLARGED VIEWS -
BASEMENT LEVEL AREA D
1 Veterans Drive, Minneapolis, MN 55417
B70
EHRM INFRASTRUCTURE
UPGRADESFINAL BID DOCUMENTS
1" = 10'-0" F4
ARCHITECTURAL FLOOR PLAN - BASMENT LEVEL AREA D
1/4" = 1'-0" B3
ARCHITECTURAL FLOOR PLAN - BASEMENT
LEVEL - ROOM CB35C - DEMO
1/4" = 1'-0"
B5
ARCHITECTURAL FLOOR PLAN - BASEMENT
LEVEL - ROOM CB35C - NEW
1/4" = 1'-0" B6
ARCHITECTURAL RCP - BASEMENT LEVEL -
ROOM CB35C - DEMO
1/4" = 1'-0"
B8
ARCHITECTURAL RCP - BASEMENT LEVEL -
ROOM CB35C - NEW
1 REMOVE FLOORING AND WALL BASE IN ROOM.
2 NEW 45 MIN SMOKE RATED DOOR. SEE DOOR SCHEDULE AND
SPECIFICATIONS FOR ADDITIONAL INFORMATION. COORDINATE DOOR
AND FRAME WITH ACCESS CONTROL HARDWARE.
3 REMOVE EXISTING ACOUSTICAL CEILING AND LIGHTS. MODIFY
AND/OR PROVIDE ADDITIONAL SUPPORTS AS REQUIRED FOR
EXISTING CEILING ITEMS TO REMAIN.
4 TELECOM ROOM TO BE OPEN TO DECK ABOVE.
5 PROVIDE NEW FIRE EXTINGUISHER CABINET WITH A TYPE 2A:10B:C
CLEAN AGENT FIRE EXTINGUISHER LOCATED NO GREATER THAN 75
FEET AWAY FROM THE NEW TR. CONTRACTOR TO COORDINATE THE
NEW LOCATION WITH THE COR. CONTRACTOR SHALL BID A NEW FEC
FOR EACH TR IN THE SCOPE OF WORK. SEE SPECIFICATION 10 44 13.
3/4" = 1'-0" C7
NEW DOOR IN EXISTING WALL
/06
GENERAL NOTES
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
NEW CONSTRUCTION, WITH PARTITION TYPE
A
A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT
REQUIREMENTS AND PROJECT LOCATION DRAWINGS.
B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES
INFORMATION.
C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
SYSTEMS INFORMATION.
D. NEW IT CLOSETS SHALL BE SMOKE RATED AND COMPLY WITH THE
LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS
STANDARDS.
E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.
F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.
G. SEE TYPICAL CEILING DETAILS ON SHEET A-531
PARTITION RATING GRAPHICS:
2 HR FIRE SHAFT
1 HR SMOKE BARRIER
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION:
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND
SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.
1 HR INCIDENTAL USE
1 HR FIRE & SMOKE BARRIER
HJKLMNPQRSTUV
BB-101BB-101 BB-102BB-102 BB-103BB-103 BB-104BB-104 BB-105BB-105 BB-106BB-106 BB-107BB-107 BB-108BB-108 BB-109BB-109
BA-113BA-113
BA-110BA-110
M-1M-1 TELECOM
ROOM
BC-101BC-101
ELECTRICAL
ROOM
BC-102BC-102
BC-103BC-103
DD
BF-101BF-101
BF-102BF-102
BF-103BF-103
BF-104BF-104 BF-105BF-105 BF-106BF-106
BF-107BF-107 BF-108BF-108
BF-109BF-109
BF-110BF-110
BF-111BF-111
BF-112BF-112
BF-113BF-113
BF-114BF-114
BF-115BF-115
BF-116BF-116
BF-117BF-117 BF-118BF-118
BF-119BF-119
BF-120BF-120
BF-121BF-121
BF-122BF-122
BF-123BF-123
BF-124BF-124
BF-125BF-125 BF-126BF-126
BF-127BF-127
BF-128BF-128
BF-129BF-129
BF-130BF-130
BF-131BF-131 BF-132BF-132
BF-133BF-133
BF-134BF-134
BF-135BF-135
BF-136BF-136
BF-138BF-138
BF-139BF-139
BF-115ABF-115A
BF-115BBF-115B
BF-115CBF-115C
BF-115DBF-115D
BF-115EBF-115E
BF-111ABF-111A
BF-123ABF-123A
BF-125ABF-125A BF-126ABF-126A
ELECTRICAL
ROOM
BA-112BA-112
BA-109BA-109
CB32CB32
CB33CB33 CB34CB34
CB37CB37
CB38CB38
CB39CB39
CB42CB42
CB42ACB42A
CB32BCB32B
CB50CB50
CB51CB51
CB51ACB51A
CB49CB49
BC-103ABC-103A
BS-4BS-4
BH-101BH-101
BH-103BH-103
TELECOM
ROOM
BH-105BH-105ELECTRICAL
ROOM
BH-106BH-106 BH-101ABH-101A
CB-54CB-54
C-6C-6
BIOMED
COMP
ROOM
BG-111BG-111
BG-111ABG-111A
CB32ACB32A
CB31CB31
BD-115BD-115
BD-116BD-116
BB-101BB-101 BB-102BB-102 BB-103BB-103 BB-104BB-104 BB-105BB-105 BB-106BB-106 BB-107BB-107 BB-108BB-108 BB-109BB-109
BA-113BA-113
BC-104BC-104
BC-105BC-105
BC-106BC-106
BC-107BC-107 BC-108BC-108
BC-108ABC-108A
BC-105ABC-105A
BC-104ABC-104A
CB40CB40
CB41CB41
M-7M-7
CB40ACB40A
C4C4
CB31CB31
BD-115BD-115
BD-116BD-116
BB-101BB-101 BB-102BB-102 BB-103BB-103 BB-104BB-104 BB-105BB-105 BB-106BB-106 BB-107BB-107 BB-108BB-108 BB-109BB-109
BA-113BA-113
CB31CB31
BD-115BD-115
BD-116BD-116
BB-101BB-101 BB-102BB-102 BB-103BB-103 BB-104BB-104 BB-105BB-105 BB-106BB-106 BB-107BB-107 BB-108BB-108 BB-109BB-109
BA-113BA-113
BA-110BA-110
M-1M-1 TELECOM
ROOM
BC-101BC-101
BC-103BC-103
BC-104BC-104
BC-105BC-105
BC-106BC-106
BC-107BC-107 BC-108BC-108
BC-108ABC-108A
BC-105ABC-105A
BC-104ABC-104A
DD
BF-101BF-101
BF-102BF-102
BF-103BF-103
BF-104BF-104 BF-105BF-105 BF-106BF-106
BF-107BF-107 BF-108BF-108
BF-109BF-109
BF-110BF-110
BF-111BF-111
BF-112BF-112
BF-113BF-113
BF-114BF-114
BF-115BF-115
BF-116BF-116
BF-117BF-117 BF-118BF-118
BF-119BF-119
BF-120BF-120
BF-121BF-121
BF-122BF-122
BF-123BF-123
BF-124BF-124
BF-125BF-125 BF-126BF-126
BF-127BF-127
BF-128BF-128
BF-129BF-129
BF-130BF-130
BF-131BF-131 BF-132BF-132
BF-133BF-133
BF-134BF-134
BF-135BF-135
BF-136BF-136
BF-138BF-138
BF-139BF-139
BF-115ABF-115A
BF-115BBF-115B
BF-115CBF-115C
BF-115DBF-115D
BF-115EBF-115E
BF-111ABF-111A
BF-123ABF-123A
BF-125ABF-125A BF-126ABF-126A
TELECOM
ROOM
BA-111BA-111
ELECTRICAL
ROOM
BA-112BA-112
BA-109BA-109
CB32CB32
CB33CB33 CB34CB34
CB37CB37
CB38CB38
CB39CB39
CB40CB40
CB41CB41
CB42CB42
CB42ACB42A
CB32BCB32B
CB50CB50
CB51CB51
CB51ACB51A
CB49CB49
M-7M-7
CB40ACB40A
BC-103ABC-103A
BS-4BS-4
C4C4
BH-101BH-101
BH-103BH-103
TELECOM
ROOM
BH-105BH-105ELECTRICAL
ROOM
BH-106BH-106 BH-101ABH-101A
CB-54CB-54
C-6C-6
CB32ACB32A
CB31CB31BH-111IBH-111I
on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot
REVISIONS DATE
General Notes:
GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO
THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED
BY THE VARIOUS SUBCONTRACTORS.
Approved: Division Chief
Issue Date Checked Drawn
DrawingNumber
Building Number
Project NumberDrawing Title Project Title
Location Drawing Scale
Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs
Office of Construction and Facilities Management
FULLY SPRINKLERED
Phase
NOT FOR CONSTRUCTION
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
TRUE NORTH
PLAN NORTH
KEYPLANA/E:
TRIPLE C - The A/E Group
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
A
B
D
F
G
H
J
K
L
M
N
As indicated
B
IM
/6
-2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e s M
P L S
V A
M C
/6 -2
-7
.M
E H
R M
.A R
C H
.B .L
.r v t
/5
/2
:1
:0
A
M
05/06/2022 M. Perkins K. McDermott
618-21-700
1383 - 70A-400F
ARCHITECTURAL ENLARGED VIEWS -
BASEMENT LEVEL AREA F
1 Veterans Drive, Minneapolis, MN 55417
B70
EHRM INFRASTRUCTURE
UPGRADESFINAL BID DOCUMENTS
1" = 10'-0" F2
ARCHITECTURAL FLOOR PLAN - BASEMENT LEVEL AREA F
NOT USED
/06
UP
UP
SHEET SYMBOL LEGEND
KEYNOTES
GENERAL NOTES
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
NEW CONSTRUCTION, WITH PARTITION TYPE
A
A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT
REQUIREMENTS AND PROJECT LOCATION DRAWINGS.
B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES
INFORMATION.
C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
SYSTEMS INFORMATION.
D. NEW IT CLOSETS SHALL BE SMOKE RATED AND COMPLY WITH THE
LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS
STANDARDS.
E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.
F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.
G. SEE TYPICAL CEILING DETAILS ON SHEET A-531
PARTITION RATING GRAPHICS:
2 HR FIRE SHAFT
1 HR SMOKE BARRIER
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION:
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND
SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.
1 HR INCIDENTAL USE
1 HR FIRE & SMOKE BARRIER
QRSTUVW
BF-103BF-103
EE
BH-101BH-101
BH-102BH-102
BH-103BH-103
BH-104BH-104
TELECOM
ROOM
BH-105BH-105
ELECTRICAL
ROOM
BH-106BH-106
BH-107BH-107 BH-108BH-108 BH-109BH-109 BH-110BH-110
MAIN
TELEPHONE
ROOM
BH-111BH-111
BH-112BH-112BH-113BH-113
BH-114BH-114
BH-115BH-115
BH-100BH-100
BH-101ABH-101A
BH-104ABH-104A
CB-54CB-54
CB-43CB-43
CB-46CB-46
CB-47CB-47
CB-48CB-48
C-6C-6
C-7C-7
CB-52CB-52
CB-53CB-53
M-8M-8
CB-55CB-55
CB-56CB-56
BG-102BG-102
BG-103BG-103 BG-104BG-104
BG-105BG-105
BG-106BG-106
BG-107BG-107
BG-112BG-112
BG-105ABG-105A
BG-105BBG-105B
CB-93CB-93
CB-94CB-94
MAIN
SERVER
ROOM
(ORANGE-STACK)
BH-111ABH-111A
BF-103BF-103
EE
BH-101BH-101
BH-102BH-102
BH-103BH-103
BH-104BH-104
ELECTRICAL
ROOM
BH-106BH-106
BH-107BH-107 BH-108BH-108 BH-109BH-109 BH-110BH-110
BH-112BH-112BH-113BH-113
BH-114BH-114
BH-115BH-115
BH-100BH-100
BH-101ABH-101A
BH-104ABH-104A
CB-54CB-54
CB-43CB-43
CB-46CB-46
CB-47CB-47
CB-48CB-48
C-6C-6
C-7C-7
CB-52CB-52
CB-53CB-53
M-8M-8
CB-55CB-55
CB-56CB-56
C5C5
BG-103BG-103 BG-104BG-104
BG-105BG-105
BG-112BG-112
BG-105ABG-105A
BG-105BBG-105B
CB-93CB-93
CB-94CB-94
70A-400G
B2
70A-400G
B6
RST
MAIN
SERVER
ROOM
(ORANGE-STACK)
BH-111ABH-111A
MAIN
SERVER
ROOM
(ORANGE-STACK)
BH-111ABH-111A
MAIN
SERVER
ROOM
(ORANGE-STACK)
BH-111ABH-111A
on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot
REVISIONS DATE
General Notes:
GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO
THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED
BY THE VARIOUS SUBCONTRACTORS.
Approved: Division Chief
Issue Date Checked Drawn
DrawingNumber
Building Number
Project NumberDrawing Title Project Title
Location Drawing Scale
Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs
Office of Construction and Facilities Management
FULLY SPRINKLERED
Phase
NOT FOR CONSTRUCTION
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
TRUE NORTH
PLAN NORTH
KEYPLANA/E:
TRIPLE C - The A/E Group
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
A
B
D
F
G
H
J
K
L
M
N
As indicated
B
IM
/6
-2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e s M
P L S
V A
M C
/6 -2
-7
.M
E H
R M
.A R
C H
.B .L
.r v t
/5
/2
:1
:1
A
M
05/06/2022 M. Perkins K. McDermott
618-21-700
1383 - 70A-400G
ARCHITECTURAL ENLARGED VIEWS -
BASEMENT LEVEL AREA G
1 Veterans Drive, Minneapolis, MN 55417
B70
EHRM INFRASTRUCTURE
UPGRADESFINAL BID DOCUMENTS
1" = 10'-0" F2
ARCHITECTURAL FLOOR PLAN - BASEMENT LEVEL AREA G
1 EXISTING ACOUSTICAL CEILING TO REMAIN.
2 EXISTING FLOORING AND WALL BASE TO REMAIN.
1/4" = 1'-0" B2
ARCHITECTURAL FLOOR PLAN - BASEMENT
LEVEL - ROOM BH-111 - DEMO
1/4" = 1'-0" B6
ARCHITECTURAL FLOOR PLAN - BASEMENT
LEVEL - ROOM BH-111 - NEW
SCALE: 1/4" = 1'-0"
F6
ARCHITECTURAL RCP - BASEMENT
LEVEL - ROOM BH-111A - EXISTING TO
REMAIN
/06
GENERAL NOTES
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
NEW CONSTRUCTION, WITH PARTITION TYPE
A
A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT
REQUIREMENTS AND PROJECT LOCATION DRAWINGS.
B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES
INFORMATION.
C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
SYSTEMS INFORMATION.
D. NEW IT CLOSETS SHALL BE SMOKE RATED AND COMPLY WITH THE
LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS
STANDARDS.
E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.
F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.
G. SEE TYPICAL CEILING DETAILS ON SHEET A-531
PARTITION RATING GRAPHICS:
2 HR FIRE SHAFT
1 HR SMOKE BARRIER
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION:
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND
SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.
1 HR INCIDENTAL USE
1 HR FIRE & SMOKE BARRIER
TUVWX
CB-95CB-95
CB-96CB-96
CB-95ACB-95A
CB-95BCB-95B
C7C7
BJ-101BJ-101
CB-95CB-95
CB-96CB-96
CB-95ACB-95A
CB-95BCB-95B
on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot
REVISIONS DATE
General Notes:
GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO
THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED
BY THE VARIOUS SUBCONTRACTORS.
Approved: Division Chief
Issue Date Checked Drawn
DrawingNumber
Building Number
Project NumberDrawing Title Project Title
Location Drawing Scale
Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs
Office of Construction and Facilities Management
FULLY SPRINKLERED
Phase
NOT FOR CONSTRUCTION
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
TRUE NORTH
PLAN NORTH
KEYPLANA/E:
TRIPLE C - The A/E Group
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
A
B
D
F
G
H
J
K
L
M
N
As indicated
B
IM
/6
-2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e s M
P L S
V A
M C
/6 -2
-7
.M
E H
R M
.A R
C H
.B .L
.r v t
/5
/2
:1
:2
A
M
05/06/2022 M. Perkins K. McDermott
618-21-700
1383 - 70A-400H
ARCHITECTURAL ENLARGED VIEWS -
BASEMENT LEVEL AREA H
1 Veterans Drive, Minneapolis, MN 55417
B70
EHRM INFRASTRUCTURE
UPGRADESFINAL BID DOCUMENTS
1" = 10'-0" F6
ARCHITECTURAL FLOOR PLAN - BASEMENT LEVEL AREA H
NOT USED
/06
GENERAL NOTES
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
NEW CONSTRUCTION, WITH PARTITION TYPE
A
A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT
REQUIREMENTS AND PROJECT LOCATION DRAWINGS.
B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES
INFORMATION.
C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
SYSTEMS INFORMATION.
D. NEW IT CLOSETS SHALL BE SMOKE RATED AND COMPLY WITH THE
LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS
STANDARDS.
E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.
F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.
G. SEE TYPICAL CEILING DETAILS ON SHEET A-531
PARTITION RATING GRAPHICS:
2 HR FIRE SHAFT
1 HR SMOKE BARRIER
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION:
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND
SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.
1 HR INCIDENTAL USE
1 HR FIRE & SMOKE BARRIER
WXYZAABBCCDDEEFFGGHHJJ
BG-101BG-101
BG-102BG-102
BG-103BG-103 BG-104BG-104
BG-105BG-105
BG-106BG-106
BG-107BG-107
BG-108BG-108
BG-109BG-109
BG-110BG-110
BIOMED
COMP
ROOM
BG-111BG-111
BG-112BG-112
BG-111ABG-111A
BG-105ABG-105A
BG-105BBG-105B
BJ-101BJ-101
BJ-102BJ-102
BJ-103BJ-103
TELECOM
ROOM
BJ-103ABJ-103A
BJ-103CBJ-103C
ELECTRICAL
ROOM
BJ-103DBJ-103D
TELECOM
ROOM
BJ-103EBJ-103E
CB-92CB-92
CB-93CB-93
CB-94CB-94
CB-97CB-97
CB-98CB-98
CB-99CB-99
CB-100CB-100
BM-131BM-131
BM-128BM-128
BM-129BM-129
BM-130BM-130
BM-123ABM-123A
BM-123BBM-123B
BM-123CBM-123C
BM-123DBM-123D
BM-123EBM-123E
BM-123FBM-123F
BM-123GBM-123G BM-123HBM-123H
BM-123JBM-123J
BM-123KBM-123K
BJ-103FBJ-103F
BP-123LBP-123L
CB-89CB-89CB-90CB-90
BG-104BG-104
BG-105BG-105
BIOMED
COMP
ROOM
BG-111BG-111
BG-101BG-101
BG-102BG-102
BG-103BG-103 BG-104BG-104
BG-105BG-105
BG-106BG-106
BG-107BG-107
BG-108BG-108
BG-109BG-109
BG-110BG-110
BIOMED
COMP
ROOM
BG-111BG-111
BG-112BG-112
BG-105ABG-105A
BG-105BBG-105B
BJ-101BJ-101
BJ-102BJ-102
BJ-103BJ-103
TELECOM
ROOM
BJ-103ABJ-103A
ELECTRICAL
ROOM
BJ-103BBJ-103B
BJ-103CBJ-103C
CB-92CB-92
CB-93CB-93
CB-94CB-94
CB-97CB-97
CB-98CB-98
CB-99CB-99
CB-100CB-100
BM-131BM-131
BM-128BM-128
BM-129BM-129
BM-130BM-130
BM-123ABM-123A
BM-123BBM-123B
BM-123CBM-123C
BM-123DBM-123D
BM-123EBM-123E
BM-123FBM-123F
BM-123GBM-123G BM-123HBM-123H
BM-123JBM-123J
BM-123KBM-123K
BJ-103FBJ-103F
BP-123LBP-123L
CB-89CB-89CB-90CB-90
on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot
REVISIONS DATE
General Notes:
GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO
THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED
BY THE VARIOUS SUBCONTRACTORS.
Approved: Division Chief
Issue Date Checked Drawn
DrawingNumber
Building Number
Project NumberDrawing Title Project Title
Location Drawing Scale
Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs
Office of Construction and Facilities Management
FULLY SPRINKLERED
Phase
NOT FOR CONSTRUCTION
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
TRUE NORTH
PLAN NORTH
KEYPLANA/E:
TRIPLE C - The A/E Group
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
A
B
D
F
G
H
J
K
L
M
N
As indicated
B
IM
/6
-2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e s M
P L S
V A
M C
/6 -2
-7
.M
E H
R M
.A R
C H
.B .L
.r v t
/5
/2
:1
:4
A
M
05/06/2022 M. Perkins K. McDermott
618-21-700
1383 - 70A-400J
ARCHITECTURAL ENLARGED VIEWS -
BASEMENT LEVEL AREA J
1 Veterans Drive, Minneapolis, MN 55417
B70
EHRM INFRASTRUCTURE
UPGRADESFINAL BID DOCUMENTS
1" = 10'-0" F2
ARCHITECTURAL FLOOR PLAN - BASEMENT LEVEL AREA J
NOT USED
/06
GENERAL NOTES
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
NEW CONSTRUCTION, WITH PARTITION TYPE
A
A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT
REQUIREMENTS AND PROJECT LOCATION DRAWINGS.
B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES
INFORMATION.
C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
SYSTEMS INFORMATION.
D. NEW IT CLOSETS SHALL BE SMOKE RATED AND COMPLY WITH THE
LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS
STANDARDS.
E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.
F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.
G. SEE TYPICAL CEILING DETAILS ON SHEET A-531
PARTITION RATING GRAPHICS:
2 HR FIRE SHAFT
1 HR SMOKE BARRIER
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION:
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND
SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.
1 HR INCIDENTAL USE
1 HR FIRE & SMOKE BARRIER
WXYZAABBCCDDEEFFGGHHJJ
CB32BCB32B
BG-101BG-101
BM-131BM-131
BM-123BBM-123B
BM-123CBM-123C
BM-123EBM-123E
BM-123GBM-123G BM-123HBM-123H
BG-101BG-101
BM-123BM-123
BM-123ABM-123A
BP-123LBP-123L
BM-101BM-101
BM-102BM-102
BM-103BM-103
BM-104BM-104
BM-105BM-105
BM-107BM-107
BM-108BM-108
BM-108ABM-108A
BM-109BM-109
BM-110BM-110
BM-111BM-111
BM-112BM-112BM-113BM-113
BM-114BM-114
BM-115BM-115
BM-116BM-116
BM-117BM-117
BM-118BM-118
BM-119BM-119
BM-120BM-120
BM-121BM-121
BM-122BM-122
BA-101BA-101
BA-102BA-102
TELECOM
ROOM
BA-103BA-103
ELECTRICAL
ROOM
BA-104BA-104
BA-105BA-105
BA-106BA-106
BA-107BA-107
BM-116ABM-116ABM-116BBM-116B
BM-116CBM-116CBM-116DBM-116D
BM-124BM-124
BM-125BM-125
BM-126BM-126
BM-127BM-127
FF
CB-86CB-86
BM-111ABM-111A
BM-111BBM-111B
BM-111CBM-111C
BM-111DBM-111D
BM-111EBM-111E
BM-119ABM-119A
BM-119BBM-119B BM-119CBM-119C
BM-119DBM-119D
BM-119EBM-119E
BM-107ABM-107A
BM-107BBM-107B
BM-107CBM-107C
BM-107DBM-107D
CB-79ACB-79A
CB-87CB-87
CB-88CB-88
CB-89CB-89CB-90CB-90
CB-92ACB-92A
CB32BCB32B
CB31CB31
GG
CB-86CB-86
BN-101BN-101
BN-105BN-105
BN-106BN-106 BN-107BN-107
CB-101CB-101
BP-105BP-105
BP-105ABP-105A
BM-131BM-131
BP-105BP-105
BP-105ABP-105A
TELECOM
ROOM
(BLUE-STACK)
BM-122A
ACTUAL: 172 SF
PROG: 170 SF
PRIMARY
CB32BCB32B
BG-101BG-101
BM-131BM-131
BM-123BBM-123B
BM-123CBM-123C
BM-123EBM-123E
BM-123GBM-123G BM-123HBM-123H
BM-123BM-123
BP-123LBP-123L
BM-101BM-101
BM-102BM-102
BM-103BM-103
BM-104BM-104
BM-105BM-105
BM-107BM-107
BM-108BM-108
BM-108ABM-108A
BM-109BM-109
BM-110BM-110
BM-111BM-111
BM-112BM-112BM-113BM-113
BM-114BM-114
BM-115BM-115
BM-116BM-116
BM-117BM-117
BM-118BM-118
BM-119BM-119
BM-120BM-120
BM-121BM-121
BM-122BM-122
BA-101BA-101
BA-102BA-102
BA-105BA-105
BA-107BA-107
BM-116ABM-116ABM-116BBM-116B
BM-116CBM-116CBM-116DBM-116D
BM-124BM-124
BM-125BM-125
BM-126BM-126
BM-127BM-127
FF
CB-86CB-86
BM-111ABM-111A
BM-111BBM-111B
BM-111CBM-111C
BM-111DBM-111D
BM-111EBM-111E
BM-119ABM-119A
BM-119BBM-119B BM-119CBM-119C
BM-119DBM-119D
BM-119EBM-119E
BS-7BS-7
M3M3
M2M2
BM-107ABM-107A
BM-107BBM-107B
BM-107CBM-107C
BM-107DBM-107D
C10C10
M9M9
CB-87CB-87
CB-88CB-88
CB-89CB-89CB-90CB-90
CB-92ACB-92A
CB31CB31
GG BN-101BN-101
BN-105BN-105
BN-106BN-106 BN-107BN-107
AA
CB-101CB-101
BP-105BP-105
ELECTRICAL
ROOM
BP-107BP-107
BP-105ABP-105A
BP-118BP-118
TELECOM
ROOM
BP-107ABP-107A
70A-400K
B2
70A-400K
B4
3'-4" 4"
TELECOM
ROOM
(BLUE-STACK)
BM-122ABM-122A
A3
B
B
B
B
B
B
12'-9 5/8"
B M
-1
AA
3'-0"
3' -2
TELECOM
ROOM
(BLUE-STACK)
BM-122ABM-122A
BM-122BM-122
BM-122BM-122
on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot
REVISIONS DATE
General Notes:
GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO
THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED
BY THE VARIOUS SUBCONTRACTORS.
Approved: Division Chief
Issue Date Checked Drawn
DrawingNumber
Building Number
Project NumberDrawing Title Project Title
Location Drawing Scale
Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs
Office of Construction and Facilities Management
FULLY SPRINKLERED
Phase
NOT FOR CONSTRUCTION
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
TRUE NORTH
PLAN NORTH
KEYPLANA/E:
TRIPLE C - The A/E Group
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
A
B
D
F
G
H
J
K
L
M
N
As indicated
B
IM
/6
-2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e s M
P L S
V A
M C
/6 -2
-7
.M
E H
R M
.A R
C H
.B .L
.r v t
/5
/2
:1
:1
A
M
05/06/2022 M. Perkins K. McDermott
618-21-700
1383 - 70A-400K
ARCHITECTURAL ENLARGED VIEWS -
BASEMENT LEVEL AREA K
1 Veterans Drive, Minneapolis, MN 55417
B70
EHRM INFRASTRUCTURE
UPGRADESFINAL BID DOCUMENTS
1" = 10'-0" F1
ARCHITECTURAL FLOOR PLAN - BASEMENT LEVEL AREA K
1 REMOVE EXISTING WALL AND FRAMING.
2 REMOVE EXISTNG DOOR AND FRAME. INFILL OPENING TO MATCH
ADJACENT CONSTRUCTION AND FINISH FOR CONTINUOUS SURFACE.
3 REMOVE FLOORING AND WALL BASE IN ROOM.
4 REMOVE PORTION OF WALL FOR NEW DOOR.
5 REMOVE EXISTING SINK. CAP PLUMBING.
6 NEW 45 MIN SMOKE RATED DOOR. SEE DOOR SCHEDULE AND
SPECIFICATIONS FOR ADDITIONAL INFORMATION. COORDINATE DOOR
AND FRAME WITH ACCESS CONTROL HARDWARE.
7 REMOVE EXISTING ACOUSTICAL CEILING AND LIGHTS. MODIFY
AND/OR PROVIDE ADDITIONAL SUPPORTS AS REQUIRED FOR
EXISTING CEILING ITEMS TO REMAIN.
8 EXISTING ACOUSTICAL CEILING TO REMAIN. MODIFY AS NEEDED FOR
NEW WALLS.
9 TELECOM ROOM TO BE OPEN TO DECK ABOVE.
10 PROVIDE NEW FIRE EXTINGUISHER CABINET WITH A TYPE 2A:10B:C
CLEAN AGENT FIRE EXTINGUISHER LOCATED NO GREATER THAN 75
FEET AWAY FROM THE NEW TR. CONTRACTOR TO COORDINATE THE
NEW LOCATION WITH THE COR. CONTRACTOR SHALL BID A NEW FEC
FOR EACH TR IN THE SCOPE OF WORK. SEE SPECIFICATION 10 44 13.
11 TEMPORARY WALLS AND DOOR FOR ICRA ENCLOSURE. RE: ICRA
REQUIREMENTS
1/4" = 1'-0" B2
ARCHITECTURAL FLOOR PLAN - BASEMENT
LEVEL - ROOM BM-122A - DEMO
1/4" = 1'-0" B4
ARCHITECTURAL FLOOR PLAN - BASEMENT
LEVEL - ROOM BM-122A - NEW
1/4" = 1'-0"
B5
ARCHITECTURAL RCP - BASEMENT LEVEL -
ROOM BM-122A - DEMO
1/4" = 1'-0"
B7
ARCHITECTURAL RCP - BASEMENT LEVEL -
ROOM BM-122A - NEW
/06
GENERAL NOTES
EXISTING CONSTRUCTION TO REMAIN
EXISTING CONSTRUCTION TO BE DEMOLISHED
NEW CONSTRUCTION, WITH PARTITION TYPE
A
A. SEE GENERAL NOTES AND PLANS FOR TYPICAL GENERAL PROJECT
REQUIREMENTS AND PROJECT LOCATION DRAWINGS.
B. SEE INTERIOR FINISH DRAWINGS FOR ADDITIONAL FINISHES
INFORMATION.
C. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL
SYSTEMS INFORMATION.
D. NEW IT CLOSETS SHALL BE SMOKE RATED AND COMPLY WITH THE
LATEST VA PHYSICAL SECURITY STANDARDS, AND CAMPUS
STANDARDS.
E. SEE TYPICAL WALL FRAMING DETAILS ON SHEET A-511.
F. SEE TYPICAL HEAD OF WALL DETAIL ON SHEET A-512.
G. SEE TYPICAL CEILING DETAILS ON SHEET A-531
PARTITION RATING GRAPHICS:
2 HR FIRE SHAFT
1 HR SMOKE BARRIER
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION:
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND
SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.
1 HR INCIDENTAL USE
1 HR FIRE & SMOKE BARRIER
VWXYZAABBCCDDEEFFGGHHJJ
CB-3CB-3
BB-128BB-128
BB-129BB-129
BB-130BB-130
BB-131BB-131
BB-132BB-132
TELECOM
ROOM
BT-102BT-102
BA-119BA-119 BA-119ABA-119A
BA-110BA-110
BF-123BF-123
TELECOM
ROOM
BA-111BA-111
ELECTRICAL
ROOM
BA-112BA-112
BA-109BA-109
BM-101BM-101
BM-117BM-117
BM-118BM-118
BM-119BM-119
BM-120BM-120
BM-121BM-121
BM-122BM-122
BM-122ABM-122A
BA-101BA-101
BA-102BA-102
TELECOM
ROOM
BA-103BA-103
ELECTRICAL
ROOM
BA-104BA-104
BA-106BA-106
FF
CB-86CB-86
BM-119BBM-119B BM-119CBM-119C
BM-119DBM-119D
BM-119EBM-119E
BM-107ABM-107A CB-79ACB-79A
CB32ACB32A
CB32BCB32B
CB31CB31
GG
CB-86CB-86
CB-79CB-79
BN-101BN-101
TELECOM
ROOM
BN-102BN-102
BN-104BN-104
BN-105BN-105
BN-106BN-106 BN-107BN-107
CB-86ACB-86A CB-81CB-81
BQ-101BQ-101
BQ-102BQ-102
BQ-103BQ-103
BQ-104BQ-104
BQ-107BQ-107
BQ-108BQ-108
BQ-109BQ-109 BQ-112BQ-112
BQ-113BQ-1…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .