618-21-700.MEHRM.FINAL.B70.20220506Part-18.pdf

PDF 14 MB Posted

Attached to
EHRM Infrastructure Upgrades Construction Design-Bid Build Project at the Minneapolis VA Medical Center (VAMC)
Solicitation number
36C77622R0045
Issued by

About this file

This document describes a federal contract opportunity for construction design and infrastructure upgrades at the Minneapolis VA Medical Center. The project involves building infrastructure to support the nationally mandated Electronic Health Record Modernization project, including constructing a new server room on the hospital roof. The solicitation will be issued as a Request for Proposal evaluated according to FAR Parts 15, 19, and 36. It is advertised as a total Service-Disabled Veteran-Owned Small Business set-aside, with proposals due to the Department of Veterans Affairs by April 29th, 2022. The period of performance is approximately 450 calendar days from issuance of the notice to proceed. The magnitude of construction is estimated between $20-50 million.

View the file

Other files

File Type Posted
Technical Question Tracking Sheet Infra Upgrades FINAL.pdf PDF
36C77622R0045 0009.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-11.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-1.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-7.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-2.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-6.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-4.pdf PDF
618-21-700.ADD-001.Summary.Log.20220707.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-9.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-5.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-10.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-3.pdf PDF
618-21-700.MEHRM.FINAL.B70.Addendum1.20220707.ReducedPart-8.pdf PDF
36C77622R0045 0008.docx DOCX document
Technical Question Tracking Sheet - Infra Upgrades - FINAL.pdf PDF
36C77622R0045 0007.pdf PDF
36C77622R0045 0006.docx DOCX document
Technical Question Tracking Sheet - Infra Upgrades - Minneapolis.docx DOCX document
36C77622R0045 0005.docx DOCX document
36C77622R0045 0004.docx DOCX document
Technical Question Tracking Sheet - Infra Upgrades.docx DOCX document
36C77622R0045 0003.pdf PDF
Site Visit Sign In sheet.pdf PDF
36C77622R0045 0002.pdf PDF
36C77622R0045 0001.pdf PDF
36C77622R0045 - Update 5.23.22.docx DOCX document
618-21-700.MEHRM.FINAL.B70.20220506Part-7.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-11.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-33-36.zip ZIP file
618-21-700.MEHRM.FINAL.B76.20220506-REDUCED.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-48-52.zip ZIP file
36C77622R0045.docx DOCX document
618-21-700.MEHRM.FINAL.B70.20220506Part-21.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-25-28.zip ZIP file
618-21-700.MEHRM.FINAL.B70.20220506Part-4.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-23.pdf PDF
618-21-700.MEHRM.FINAL.B75.20220506-REDUCED.pdf PDF
618-21-700.MEHRM.FINAL_SPECIFICATIONS.20220506Part-2.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-45-47.zip ZIP file
618-21-700.MEHRM.FINAL.B70.20220506Part-6.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-13.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-20.pdf PDF
618-21-700.MEHRM.FINAL.B73.20220506-REDUCED.pdf PDF
618-21-700.MEHRM.FINAL.B49.20220506-REDUCED.pdf PDF
01 00 00 Appendix A - Bid Form Template.xlsx XLSX spreadsheet
618-21-700.MEHRM.FINAL.SITE.20220506-REDUCED.pdf PDF
618-21-700.MEHRM.FINAL.B222.20220506-REDUCED.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-12.pdf PDF
618-21-700.MEHRM.FINAL.B70.20220506Part-16-17.zip ZIP file
Show 40 more

Latest 50 of 80 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WAP

WAP WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

PARTITION RATING GRAPHICS:

2 HR FIRE SHAFT

1 HR SMOKE BARRIER

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION:

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND

SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.

1 HR INCIDENTAL USE

C1-23-C

C1-23-B

C1-22-A

C1-23-A

C -2

-D

C -2

-E

C -2

-B

C1-22-AP-A

1U-152-AP-A

C1-35-AP-A

C1-22-AP-B

1D-120-AP-A

4-AP-A

1U-156-D

1U-156-E

1U-156-AP-A

1U-156-A

U

-1 -B

U

-1 -C

1U-151-A 1U-151-B

1U-151-C

1U-149-A1U-147-A

1U-147-AP-A

1U-146-C

1U-146-B

1U-146-A1U-116-E

1U-116-A

1U-116-B 1U-116-C

1U-116-D

1D-120-A

U

-1 -A

U

-1 -B

U

-1 -A

1U-114-AP-A

U

-1 -B

U

-1 -A

1U-110-A

U

-1 -A

C1-12-AP-A

U

-1 -A 1U-101-B

1U-101-C

U

-1 -E

U

-1 -D

1U-101-F

1U-101-G

1U-101-H

1U-101-J

1U-101-K

1U-101-L

C1-4-AP-A

C1-3-AP-A

C1-3-AP-B

C1-3-AP-C

U

-1 -B

U

-1 -C

U

-1 -D

1U-100-A

1U-133-B

1U-133-A

1U-131-AP-A

1U-131-A

U

-1 -A

U

-1 -A

U

-1 -A

U

-1 -A

U

-1 -B

1U-122-A

U

-1 -B

U

-1 -C

C1-13-AP-A

C1-12A-AP-A

1U-144-A

U

-1 -A

U

-1 -A

1U-137-A

1U-136-A

1U-123-A

1U-124-B

1U-124-A

1U-125-A

1U-143-A

1U-143-B

U

-1 -A 1U-134-B

1U-134-E1U-134-F

1U-159-A

1U-139-A

1U-139-AP-A

C1-21-AP-A

C1-17-AP-A

C1-16-A

C -1

-B

C -1

-C

C -1

-D

C1-24-AP-B

C1-24-AP-A

C1-15-AP-A

C1-15-A

C1-15-AP-B

1S-134-A

1S-134-B

S

-1 -C

1S-134-D

1S-134-AP-A

1S-134-E

1S-134-AP-B

S

-1 -A

S

-1 -C

S

-1 -B

S

-1 -A

C1-5A-A

C1-186-AP-A

S

-1 -A

S

-1 -A

S

-1 -A

1S-118-D

1S-118-C

1S-118-B

S

-1 -A

1S-119-B

1S-119-A

1S-119-C

1S-119-D

1S-119-E

1S-119-F

1S-125-AP-A

1S-120-D

1S-120-A

1S-120-B

1S-120-C

C1-187-AP-A

1S-114A-A

1S-114A-B1S-114A-C 1S-114A-D 1S-114A-E 1S-114A-F

1S-114A-G

S

-1 -A

1S-121-C 1S-121-B

S

-1 -F

S

-1 -E 1S-121-D

1S-121-G

1S-121-H 1S-121-J 1S-121-K

1S-121-L 1S-121-M

1S-121-N

1S-121-R 1S-121-Q 1S-121-P 1S-121-O

1S-121-AP-A

1S-121A-B

1S-121A-A

S

-1 A

-D

S

-1 A

-C

S

-1 A

-E

1U-107-B

1U-107-A 1U-106-A

1U-106-B

1U-105-B 1U-105-A

1U-105-AP-A

1U-102-A

1U-100B-C

1U-100B-A

1U-100B-B

U

-1 A

-A

1S-129-A

1S-127A-A

1S-127-B

1S-127-C

1S-127-AP-A

C1-24-AP-C

C -2

-B

C -2

-A

C1-25-A C1-25-J

C1-25-H

C -2

-G

C1-25-E

R

-2 -B

R

-2 -A

1R-250-C

1R-250-D

1R-250-E

1R-250-F

1R-250-G

U

-1 -A

1U-150-A

1U-150-B

1U-134-D

1U-134-C

S

-1 -A

KEYPAD

K E

Y P

A D

S

-1 -B

S

-1 -B

1S-125-A

1S-125-B

1S-127-A

1S-125-C

1S-125-E

1S-125-D

1R-250-AP-A

1R-250-AP-B

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATANO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATANO DATA NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA70T-411

F5

70T-411

F7

1U-104-CAM-01

TELECOM

ROOM

(GREEN-STACK)

1U-1041U-104

C1-3C1-3

C1-2C1-2

C1-1C1-1

CC

C1-4C1-4

1U-1001U-100

1U-100A1U-100A

C1-6C1-6

1S-1341S-134

C1-186C1-186

C1-2AC1-2A

1U-1051U-105

1U-1061U-106 1U-1071U-107 1U-1081U-108 1U-1101U-110

C1-12C1-12

1U-1011U-101

1U-100B1U-100B 1U-101A1U-101A

1C-71C-7

1U-1331U-133

C1-14C1-14

1U-1321U-132

1U-1311U-131 1U-1291U-129 1U-1281U-128 1U-1271U-127 1U-1261U-126

1U-1221U-122 1U-1301U-130

1U-1201U-120

1U-130A1U-130A

1U-109A1U-109A

1U-1091U-109 1U-1131U-1131U-1121U-112

1U-1191U-119

C1-13C1-13

1U-1111U-111

1U-1141U-114

1U-1151U-115

1U-1161U-116

C1-12AC1-12A

1U-1171U-117 1U-1441U-144

1U-1421U-142

1U-1181U-118

1U-1211U-121 1U-1381U-138

1U-1371U-1371U-1231U-123

1U-1241U-124 1U-1361U-136

1U-1251U-125

1U-1351U-135

C1-15C1-15

1S-1361S-136

C1-5aC1-5a 1S-1381S-138 1S-1291S-129

1S-1301S-130

1S-1311S-131 1616

1S-1331S-133

1S-126A1S-126A

1S-1321S-132

1S-1261S-126

1S-1251S-125 1S-1271S-127

1S-127A1S-127A

1S-127B1S-127B

1S-121A1S-121A

C1-187C1-187

1S-1211S-121

1S-114A1S-114A

1S-125A1S-125A

1S-1201S-120

1S-1191S-119

1S-1181S-1181S-1171S-1171S-1161S-1161S-1151S-115

1S-1351S-135 1S-1371S-137

C1-5C1-5 M-6M-6

1U-1461U-146

1U-1471U-147 1U-1491U-149

1U-1511U-151

1S-127H1S-127H

1S-91S-9

C1-20AC1-20A

C1-20C1-20

1U-1431U-143 1U-1481U-148 1U-1501U-150

C1-21C1-21

1U-1551U-1551U-1401U-140

C1-19C1-19

1U -1

1U

-1

1U-1591U-159

1U-1581U-158

1U-1571U-157

1U-1561U-156

ELECTRIC

ROOM

1U-1531U-153

TELECOM

ROOM

1U-1521U-152

C1-23C1-23C1-17C1-17

C1-16C1-16

C1-24C1-24

1D-1201D-120

C1-22C1-22

1D-120A1D-120A

ELECTRIC

ROOM

1D-120B1D-120B

TELECOM

ROOM

1D-120C1D-120C

C1-35C1-35

C1-167C1-167

1R-2501R-250

1S-1121S-112

1S-1001S-100

1S -1

1S

-1

1S-1071S-107

1S-1091S-109

C1-191C1-191

1S-1231S-123

1S-1101S-110

1S-1061S-106

1U-1621U-162

1U-162A1U-162A

1U-162B1U-162B C1-34AC1-34A

1D-121A1D-121A

1D-1211D-121

1D-1221D-122C1-34C1-34

1D-1171D-117

1D-1151D-115

1D-1141D-114

1D-1161D-116

1D-1181D-118

1D-1231D-123

1D-122A1D-122A1D-115A1D-115A

C1-36C1-36

C1-32C1-32 1D-116A1D-116A

1D-1251D-125

1D-1241D-124

1D-124A1D-124A

1D-125A1D-125A

1D-112A1D-112A

1D-1131D-113

1D-113A1D-113A

1D-1111D-111

1D-1121D-112

1D-1091D-109

C1-38C1-38

1D -1

1D

-1

1D-1261D-126

1D-1271D-127

1D-1301D-130

1D-1321D-132

1D-127A1D-127A

1D-1281D-128

1D-1081D-108

1D-1291D-129

1D-1061D-106 1D-1311D-131

1D-1071D-107

1D-107A1D-107A

1T-1051T-105

ELECTRIC

ROOM

1T-1031T-103

TELECOM

ROOM

1T-1041T-104

1R-1091R-109

1R-1081R-108

1S-1431S-143

1S-1441S-144

1S-21S-2

C1-194C1-194

C1-181C1-181

1V-1461V-146

1S-11S-1

ELECTRIC

ROOM

1T-1081T-108

TELECOM

ROOM

1T-1071T-107

M-5M-5

C1-185AC1-185A

C1-3AC1-3A

1V-1511V-151

C1-183AC1-183A

1V-152A1V-152A

1V-1521V-152

1V-151A1V-151A

1V-1501V-150 1V-1471V-147

C1-25C1-25

1U-1341U-134

1U-104-B

1U-104-C on e-ei gh th in ch o ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in es ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

GENERAL NOTES

KEYNOTES

A

B D

TRUE NORTH

PLAN NORTH

E F

G

H

J

K

L

M

N

C

KEYPLANA/E:

TRIPLE C - The A/E Group

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

As indicated

B

IM

/6

-2

-7

E

H R

M I n fr a s tr u c tu re U p g ra d e s M

P L S

V A

M C

/6 -2

-7

.M

E H

R M

.M E

P .B

.L

.r v t

/6

/2

:3 :5

P

M

11/05/2021 M. Perkins G. Weaver

618-21-700

1383 - 70T-101A

TELECOMMUNICATION PLAN - FIRST LEVEL

AREA A

1 Veterans Drive, Minneapolis, MN 55417

B70

EHRM INFRASTRUCTURE

UPGRADESFINAL BID DOCUMENTS

A. PROPERLY FIRE STOP AND SEAL ALL PENETRATIONS THROUGH WALLS,

FLOORS, CEILINGS, AND ROOF AS PER OWNER, CODE, AND AHJ.

B. PRIOR TO INSTALLATION OF CABLE TRAY COORDINATE LOCATIONS WITH ALL

OTHER TRADES AND PROVIDE COORDINATION DRAWINGS FOR REVIEW. ALL

NEW CABLE, CABLE TRAY, J HOOKS SHALL BE INDEPENDENTLY SUPPORTED &

NOT CAUSE ADDITIONAL LOAD ON OTHER SYSTEMS.

C. NOT ALL PARTS AND PIECES ARE SHOWN FOR A COMPLETE SYSTEM.

CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE END-TO-END

WARRANTEED SOLUTION FOR THE CABLING.

D. ALL CABLING TO BE PLENUM RATED THROUGHOUT THE BUILDING.

E. ALL COMMUNICATIONS AND WIRELESS ACCESS POINT CABLING TO MEET OR

EXCEED CATEGORY 6A STANDARDS.

F. SEE E-501 FOR DEVICE STANDARD MOUNTING HEIGHTS.

G. ALL CONDUITS FOR TELECOMMUNICATIONS OUTLETS SHALL BE STEEL THIN

WALL ELECTRICAL METALLIC TUBING (TYPE EMT) UNLESS OTHERWISE NOTED.

UNDER NO CIRCUMSTANCES SHALL FLEXIBLE CONDUIT BE USED FOR

PATHWAYS INDICATED ON THIS DRAWING. ALL CONDUITS ARE TO BE, AT A

MINIMUM, 1-1/4" TRADE SIZE, UNLESS OTHERWISE NOTED. ALL CONDUITS FOR

TELECOMMUNICATIONS OUTLETS ARE TO BE STUBBED TO NEAREST CABLE

TRAY. CONTRACTOR IS TO ENSURE THAT NO CONDUIT EXCEEDS 40% FILL. IF

EXISTING CONDUIT IS NOT LARGE ENOUGH TO SUPPORT NEW CAT 6A CABLE

TO REPLACE ALL EXISTING CIRCUITS ONE-FOR-ONE, CONTRACTOR SHALL

PROVIDE THE MAXIMUM ALLOWABLE NEW CAT 6A CIRCUITS TO REPLACE

EXISTING. THE ADDITIONAL NEW CIRCUITS TO COMPLETE THE ONE-FOR-ONE

REPLACEMENT SHALL BE PROVIDED AT THE NEAREST AVAILABLE DROP WITH

EXISTING CONDUIT CAPACITY.

H. ALL CONDUIT PATHWAYS SHALL BE PROVIDED WITH NYLON BUSHINGS TO

PROTECT CABLES, REGARDLESS OF WHETHER THEY TERMINATE IN A DEVICE

OR JUNCTION BOX.

I. TERMINATE, TEST, LABEL AND DOCUMENT ALL TELECOMMUNICATION CABLES.

J. CONTRACTOR SHALL AVOID ALL SYSTEMS SHUTDOWNS, INSTALL NEW

EQUIPMENT PRIOR TO THE RENOVATION OF EXISTING EQUIPMENT; PROVIDE

TEMPORARY UTILITIES AS REQUIRED TO MEET THIS REQUIREMENT.

K. THE DEMOLITION OF DEVICES SHALL INCLUDE ALL ASSOCIATED CABLING

BACK TO THE RACK.

L. LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL FOLLOWING ALL

STANDARDS AND REQUIREMENTS, SEE DETAIL SHEETS FOR ADDITIONAL

INFORMATION

M. CONTRACTOR SHALL PROVIDE TWO SETS OF LAMINATED FINAL

TELECOMMUNICATION ONE-LINE, RACK ELEVATION, AND CABLE SCHEDULE

DOCUMENTS. HANG ON THE WALL WITHIN THE TELECOM ROOM.

N. REFER TO T-600 SERIES SHEETS FOR PHOTO DOCUMENTATION OF EXISTING

CONDITIONS.

NOTE: NOT ALL KEYNOTES ARE USED

ON EACH SHEET

1. PROVIDE NEW TELECOMMUNICATIONS OUTLET IN EXISTING LOCATION WITH

EXISTING EMT STUB UP TO NEAREST ACCESSIBLE CEILING SPACE. SEE DETAILS

ON SHEET T-501 FOR ADDITIONAL INFORMATION.

2. EXISTING WIRELESS ACCESS POINT TO BE RETAINED AND REUSED. PROVIDE

NEW CABLING AND TELECOMMUNICATIONS OUTLET. REFER TO DETAILS ON

SHEET T-501 FOR ADDITIONAL INFORMATION.

3. PROVIDE NEW 4-POST RACK, PDU, UPS AND WIRE MANAGEMENT COMPONENTS

AS SHOWN ON T-500 SERIES AND T-600 SERIES SHEETS AND IN THE

SPECIFICATIONS. PHASE TO PROVIDE NEW RACK IN A TEMPORARY LOCATION

AND TRANSFER DATA CIRCUITS FROM THE EXISTING RACK TO THE NEW RACK.

PROVIDE TEMPORARY EXTRA LENGTH JUMPER CABLES TO EXISTING SWITCHES

AND OTHER DEVICES TO ENSURE UNINTERRUPTED SERVICE. ONCE ALL

EXISTING DATA CIRCUITS ARE RELOCATED TO NEW PATCH PANELS ON THE

NEW RACK AND ALL EXISTING DEVICES TO REMAIN ARE TRANSFERRED TO THE

NEW RACK, REMOVE THE EXISTING RACK AND INSTALL THE NEW RACKS IN THE

FINAL PERMANENT POSITION.

4. PROVIDE NEW VERTICAL WIRE MANAGEMENT SYSTEM, SEE SPECIFICATIONS

FOR ADDITIONAL INFORMATION.

5. EXISTING CABLING CONDUIT AND WIREWAYS ARE TO REMAIN AND BE

CAREFULLY PROTECTED IN PLACE. ALL EXISTING DEVICES ON THE EXISTING

RACK SHALL BE TRANSFERRED TO THE NEW SECOND LEVEL LOCATION ON THE

NEW RACK. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS SHOWING THE

PROPOSED NEW RACK ELEVATION AND PROVIDE A PHASING PLAN FOR

TRANSFERRING ALL EXISTING DEVICES TO REMAIN TO THE NEW RACKS.

6. PROVIDE NEW CABLE TRAY PER REQUIREMENTS LISTED IN CABLE TRAY

SCHEDULE. COORDINATE WITH EXISTING CONDITIONS AND SUBMIT

COORDINATION DRAWINGS FOR REVIEW PRIOR TO COMMENCING WORK.

COORDINATE FIXTURES WITH OVERHEAD TRAY. SEE T-500 SERIES SHEETS FOR

ADDITIONAL REQUIREMENTS. COORDINATE LIGHT FIXTURES WITH OVERHEAD

CABLE TRAY.

7. PROVIDE NEW IP ADDRESSABLE NETWORK CAMERA, POE+, PTZ, MOTION

SENSOR, AUTO-TRACKING, DOME WITH WALL MOUNT. BASIS OF DESIGN

WISENET XNP-6320. MOUNT AT 8’ – 6” A.F.F. TO TOP OF WALL BRACKET.

INTEGRATE CAMERA INTO EXISTING VMS. PROVIDE CONTROLLABILITY THROUGH

EXISTING IT NETWORK.

8. PROVIDE NEW DATA OUTLET, STUB-UP, AND BACK-BOX IN NEW LOCATION IN TR.

9. PROVIDE (2) STACKS OF (3)(6 TOTAL) 4” SPEED CONDUIT SLEEVE THROUGH

WALL ABOVE CEILING GRID FOR HORIZONTAL VOICE/DATA CABLING OR FIBER

WITH PLASTIC BUSHINGS ON BOTH ENDS TO PROTECT CABLES. FIRE CAULK

PENETRATION PER SPECIFICATIONS.

10. EXISTING CONDUIT THROUGH WALL OR FLOOR WITH OPTICAL CABLE TO BE

PROTECTED IN PLACE UNTIL NEW SPEED CONDUIT SLEEVE AND FIBER IS

INSTALLED. DEMOLISH EXISTING CONDUIT ONCE NEW SPEED CONDUIT SLEEVE

AND FIBER ARE OPERATIONAL. CONTRACTOR SHALL PROVIDE A PHASING PLAN

FOR TRANSFERRING FIBER.

11. EXISTING EQUIPMENT TO REMAIN, PROTECT-IN-PLACE.

12. EXISTING WALL MOUNTED FIBER SPLICE WITH MULTI-MODE OPTICAL CABLE TO

BE PROTECTED IN PLACE UNTIL NEW SPEED FIBER IS INSTALLED. DEMOLISH

EXISTING FIBER SPLICE ONCE NEW SPEED CONDUIT SLEEVE AND FIBER ARE

OPERATIONAL. CONTRACTOR SHALL PROVIDE A PHASING PLAN FOR

TRANSFERRING FIBER.

13. REMOVE DATA DEVICE AND RELOCATE, REPLACE CABLING WITH CAT6A MATCH

EXISTING CIRCUIT COUNT. PROVIDE NEW 1-1/4" CONDUIT AS INDICATED ON

T-601.

SCALE: 1" = 10'-0"

F2

TELECOMMUNICATION PLAN - FIRST

LEVEL AREA A

05/06/2022

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

PARTITION RATING GRAPHICS:

2 HR FIRE SHAFT

1 HR SMOKE BARRIER

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION:

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND

SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.

1 HR INCIDENTAL USE

1S-106-C

1S-106-B

1S-106-A

S

-1 -A 1S-107-B

1S-107-C

1S-107-D

1S-112-D

1S-112-A

1S-112-E

1S-112-B

1S-112-C

1S-112-AP-A

1S-100-A

S

-1 -B C1-25-D

C1-25-C

C1-25-B

C -2

-L

C -2

-K

1R-250-H

C1-25A-D

C1-25A-B

C1-25A-B

C1-25A-A

C1-25A-F

C1-25A-E

C1-25A-G

C -2

A

-H

C1-25A-J

C1-24-AP-D

IR-250-AP-A

C1-24-AP-E

C1-186-AP-B

S

-1 -C

C O

A X

1S-105-A 1S-102-A

1S-102-B

C1-192-C

C1-192-B

S

-1 -B

C1-196-AP-C

C1-196-AP-B

C1-196-AP-A

1A-109-AP-A

C1-24-AP-F

1B-102-A

B

-1 -H

B

-1 -G

B

-1 -F

1B-102-E

1B-102-D

1B-102-C

1B-102-B

C1-199-AP-B

C1-199-AP-A

C1-198-AP-B

1A-106-B

1A-106-A

1A-106A-A

A

-1 A

-C

A

-1 A

-B

A

-1 -A

1A-114-A

1A-114-B 1A-113-C

1A-113-B

A

-1 -E

A

-1 -A

A

-1 -C

A

-1 -B

A

-1 -D

1A-110C-B

1A-110C-A 1A-110C-C

1A-110C-D

1A-110C-D

C1-198-AP-A

1A-110-AP-B

1A-110-AP-A

1B-104-AP-A

B

-1 -A

B

-1 -B

1B-105-A

1B-105-B

1A-110C-E

1A-110C-F

NO DATA

NO DATA

NO DATANO DATA NO DATA

NO DATA

NO DATA

NO DATA

N O

D A

T A

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

N O

D A

T A

NO DATA NO DATA

NO DATA

NO DATA NO DATA NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

1S-1251S-125 1S-1271S-1271S-127B1S-127B

1S-121A1S-121A

1S-1211S-121

1R-2501R-250

1S-1281S-128

C1-192C1-192

1S-1121S-112

1S-1001S-100

1S -1

1S

-1

1S-1071S-107

1S-1091S-109

C1-191C1-191

1S-1231S-123

1S-1101S-110

1S-1061S-106

C1-196C1-196

TELECOM

ROOM

1T-1021T-102

C1-195C1-195

ELECTRIC

ROOM

1T-1011T-101 1-S31-S3

C1-197C1-197

1S -1

1S

-1

1S-1041S-104 1S-1031S-103

1S-1021S-102

1S-1011S-101

C1-193C1-193

C1-199C1-199

C1-198C1-198

C1-200C1-200

1A-1051A-105

1A-1091A-109

C1-25C1-25

1A-1041A-104 1A-1061A-106

1A-106A1A-106A

1A-110B1A-110B

1S-51S-5

ELECTRIC

ROOM

1A-1081A-108

1A-1071A-107 1A-1101A-110

1A-110C1A-110C

1A-110A1A-110A

1B-1021B-102

1B-1031B-103

1A-1151A-115

1A-1141A-114

1A-1131A-113

C1-127AC1-127A

1A-1121A-112

C1-27C1-27 1B-1041B-104

1B-1051B-105

C1-127BC1-127B

1A-112A1A-112A

C1-193AC1-193A

AA

1C-1201C-120

DD

1G-1131G-113

1G-1121G-112

1A-111A1A-111A

1G-1091G-109 1G-109B1G-109B

1G-109A1G-109A

1G-105C1G-105C

1G-1011G-101

1G-1021G-102

1G-1041G-104

1G-1031G-103

1G-101C1G-101C

1S-41S-4

ELECTRIC

ROOM

1D-1741D-174

TELECOM

ROOM

1C-1231C-123

C1-202C1-202

1R-1081R-108

1S-1431S-143

1S-1421S-142

1S-1441S-144

1S-1411S-141

1S-1401S-1401S-141A1S-141A

1R-105C1R-105C1R-1061R-106

1R-1031R-103 1R-1041R-104

M-4M-4

1R-105B1R-105B

1R-105A1R-105A

1R-1051R-105

IR-101IR-101

C1-147C1-147

1S-21S-2

1A-1021A-102

1A-1031A-103

M-2M-2

C-10C-10 1A-1011A-101

C-9C-9

C1-194C1-194

C1-194AC1-194A C1-25C1-25

1G-101A1G-101A on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

GENERAL NOTES

KEYNOTES

A

B D

TRUE NORTH

PLAN NORTH

E F

G

H

J

K

L

M

N

C

KEYPLANA/E:

TRIPLE C - The A/E Group

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

As indicated

B

IM

/6

-2

-7

E

H R

M I n fr a s tr u c tu re U p g ra d e s M

P L S

V A

M C

/6 -2

-7

.M

E H

R M

.M E

P .B

.L

.r v t

/6

/2

:3 :1

P

M

11/05/2021 M. Perkins G. Weaver

618-21-700

1383 - 70T-101B

TELECOMMUNICATION PLAN - FIRST LEVEL

AREA B

1 Veterans Drive, Minneapolis, MN 55417

B70

EHRM INFRASTRUCTURE

UPGRADESFINAL BID DOCUMENTS

A. PROPERLY FIRE STOP AND SEAL ALL PENETRATIONS THROUGH WALLS,

FLOORS, CEILINGS, AND ROOF AS PER OWNER, CODE, AND AHJ.

B. PRIOR TO INSTALLATION OF CABLE TRAY COORDINATE LOCATIONS WITH ALL

OTHER TRADES AND PROVIDE COORDINATION DRAWINGS FOR REVIEW. ALL

NEW CABLE, CABLE TRAY, J HOOKS SHALL BE INDEPENDENTLY SUPPORTED &

NOT CAUSE ADDITIONAL LOAD ON OTHER SYSTEMS.

C. NOT ALL PARTS AND PIECES ARE SHOWN FOR A COMPLETE SYSTEM.

CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE END-TO-END

WARRANTEED SOLUTION FOR THE CABLING.

D. ALL CABLING TO BE PLENUM RATED THROUGHOUT THE BUILDING.

E. ALL COMMUNICATIONS AND WIRELESS ACCESS POINT CABLING TO MEET OR

EXCEED CATEGORY 6A STANDARDS.

F. SEE E-501 FOR DEVICE STANDARD MOUNTING HEIGHTS.

G. ALL CONDUITS FOR TELECOMMUNICATIONS OUTLETS SHALL BE STEEL THIN

WALL ELECTRICAL METALLIC TUBING (TYPE EMT) UNLESS OTHERWISE NOTED.

UNDER NO CIRCUMSTANCES SHALL FLEXIBLE CONDUIT BE USED FOR

PATHWAYS INDICATED ON THIS DRAWING. ALL CONDUITS ARE TO BE, AT A

MINIMUM, 1-1/4" TRADE SIZE, UNLESS OTHERWISE NOTED. ALL CONDUITS FOR

TELECOMMUNICATIONS OUTLETS ARE TO BE STUBBED TO NEAREST CABLE

TRAY. CONTRACTOR IS TO ENSURE THAT NO CONDUIT EXCEEDS 40% FILL. IF

EXISTING CONDUIT IS NOT LARGE ENOUGH TO SUPPORT NEW CAT 6A CABLE

TO REPLACE ALL EXISTING CIRCUITS ONE-FOR-ONE, CONTRACTOR SHALL

PROVIDE THE MAXIMUM ALLOWABLE NEW CAT 6A CIRCUITS TO REPLACE

EXISTING. THE ADDITIONAL NEW CIRCUITS TO COMPLETE THE ONE-FOR-ONE

REPLACEMENT SHALL BE PROVIDED AT THE NEAREST AVAILABLE DROP WITH

EXISTING CONDUIT CAPACITY.

H. ALL CONDUIT PATHWAYS SHALL BE PROVIDED WITH NYLON BUSHINGS TO

PROTECT CABLES, REGARDLESS OF WHETHER THEY TERMINATE IN A DEVICE

OR JUNCTION BOX.

I. TERMINATE, TEST, LABEL AND DOCUMENT ALL TELECOMMUNICATION CABLES.

J. CONTRACTOR SHALL AVOID ALL SYSTEMS SHUTDOWNS, INSTALL NEW

EQUIPMENT PRIOR TO THE RENOVATION OF EXISTING EQUIPMENT; PROVIDE

TEMPORARY UTILITIES AS REQUIRED TO MEET THIS REQUIREMENT.

K. THE DEMOLITION OF DEVICES SHALL INCLUDE ALL ASSOCIATED CABLING

BACK TO THE RACK.

L. LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL FOLLOWING ALL

STANDARDS AND REQUIREMENTS, SEE DETAIL SHEETS FOR ADDITIONAL

INFORMATION

M. CONTRACTOR SHALL PROVIDE TWO SETS OF LAMINATED FINAL

TELECOMMUNICATION ONE-LINE, RACK ELEVATION, AND CABLE SCHEDULE

DOCUMENTS. HANG ON THE WALL WITHIN THE TELECOM ROOM.

N. REFER TO T-600 SERIES SHEETS FOR PHOTO DOCUMENTATION OF EXISTING

CONDITIONS.

NOTE: NOT ALL KEYNOTES ARE USED

ON EACH SHEET

1. PROVIDE NEW TELECOMMUNICATIONS OUTLET IN EXISTING LOCATION WITH

EXISTING EMT STUB UP TO NEAREST ACCESSIBLE CEILING SPACE. SEE DETAILS

ON SHEET T-501 FOR ADDITIONAL INFORMATION.

2. EXISTING WIRELESS ACCESS POINT TO BE RETAINED AND REUSED. PROVIDE

NEW CABLING AND TELECOMMUNICATIONS OUTLET. REFER TO DETAILS ON

SHEET T-501 FOR ADDITIONAL INFORMATION.

3. PROVIDE NEW 4-POST RACK, PDU, UPS AND WIRE MANAGEMENT COMPONENTS

AS SHOWN ON T-500 SERIES AND T-600 SERIES SHEETS AND IN THE

SPECIFICATIONS. PHASE TO PROVIDE NEW RACK IN A TEMPORARY LOCATION

AND TRANSFER DATA CIRCUITS FROM THE EXISTING RACK TO THE NEW RACK.

PROVIDE TEMPORARY EXTRA LENGTH JUMPER CABLES TO EXISTING SWITCHES

AND OTHER DEVICES TO ENSURE UNINTERRUPTED SERVICE. ONCE ALL

EXISTING DATA CIRCUITS ARE RELOCATED TO NEW PATCH PANELS ON THE

NEW RACK AND ALL EXISTING DEVICES TO REMAIN ARE TRANSFERRED TO THE

NEW RACK, REMOVE THE EXISTING RACK AND INSTALL THE NEW RACKS IN THE

FINAL PERMANENT POSITION.

4. PROVIDE NEW VERTICAL WIRE MANAGEMENT SYSTEM, SEE SPECIFICATIONS

FOR ADDITIONAL INFORMATION.

5. EXISTING CABLING CONDUIT AND WIREWAYS ARE TO REMAIN AND BE

CAREFULLY PROTECTED IN PLACE. ALL EXISTING DEVICES ON THE EXISTING

RACK SHALL BE TRANSFERRED TO THE NEW SECOND LEVEL LOCATION ON THE

NEW RACK. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS SHOWING THE

PROPOSED NEW RACK ELEVATION AND PROVIDE A PHASING PLAN FOR

TRANSFERRING ALL EXISTING DEVICES TO REMAIN TO THE NEW RACKS.

6. PROVIDE NEW CABLE TRAY PER REQUIREMENTS LISTED IN CABLE TRAY

SCHEDULE. COORDINATE WITH EXISTING CONDITIONS AND SUBMIT

COORDINATION DRAWINGS FOR REVIEW PRIOR TO COMMENCING WORK.

COORDINATE FIXTURES WITH OVERHEAD TRAY. SEE T-500 SERIES SHEETS FOR

ADDITIONAL REQUIREMENTS. COORDINATE LIGHT FIXTURES WITH OVERHEAD

CABLE TRAY.

7. PROVIDE NEW IP ADDRESSABLE NETWORK CAMERA, POE+, PTZ, MOTION

SENSOR, AUTO-TRACKING, DOME WITH WALL MOUNT. BASIS OF DESIGN

WISENET XNP-6320. MOUNT AT 8’ – 6” A.F.F. TO TOP OF WALL BRACKET.

INTEGRATE CAMERA INTO EXISTING VMS. PROVIDE CONTROLLABILITY THROUGH

EXISTING IT NETWORK.

8. PROVIDE NEW DATA OUTLET, STUB-UP, AND BACK-BOX IN NEW LOCATION IN TR.

9. PROVIDE (2) STACKS OF (3)(6 TOTAL) 4” SPEED CONDUIT SLEEVE THROUGH

WALL ABOVE CEILING GRID FOR HORIZONTAL VOICE/DATA CABLING OR FIBER

WITH PLASTIC BUSHINGS ON BOTH ENDS TO PROTECT CABLES. FIRE CAULK

PENETRATION PER SPECIFICATIONS.

10. EXISTING CONDUIT THROUGH WALL OR FLOOR WITH OPTICAL CABLE TO BE

PROTECTED IN PLACE UNTIL NEW SPEED CONDUIT SLEEVE AND FIBER IS

INSTALLED. DEMOLISH EXISTING CONDUIT ONCE NEW SPEED CONDUIT SLEEVE

AND FIBER ARE OPERATIONAL. CONTRACTOR SHALL PROVIDE A PHASING PLAN

FOR TRANSFERRING FIBER.

11. EXISTING EQUIPMENT TO REMAIN, PROTECT-IN-PLACE.

12. EXISTING WALL MOUNTED FIBER SPLICE WITH MULTI-MODE OPTICAL CABLE TO

BE PROTECTED IN PLACE UNTIL NEW SPEED FIBER IS INSTALLED. DEMOLISH

EXISTING FIBER SPLICE ONCE NEW SPEED CONDUIT SLEEVE AND FIBER ARE

OPERATIONAL. CONTRACTOR SHALL PROVIDE A PHASING PLAN FOR

TRANSFERRING FIBER.

13. REMOVE DATA DEVICE AND RELOCATE, REPLACE CABLING WITH CAT6A MATCH

EXISTING CIRCUIT COUNT. PROVIDE NEW 1-1/4" CONDUIT AS INDICATED ON

T-601.

SCALE: 1" = 10'-0"

F3

TELECOMMUNICATION PLAN - FIRST

LEVEL AREA B

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

PARTITION RATING GRAPHICS:

2 HR FIRE SHAFT

1 HR SMOKE BARRIER

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION:

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND

SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.

1 HR INCIDENTAL USE

D

-1 -C

D

-1 -A

D

-1 -B

D

-1 -A

D

-1 -B

D

-1 -C

D

-1 -C

D

-1 -B

D

-1 -A

D

-1 -A

D

-1 -B

D

-1 -C

1D-124-AP-A

D

-1 -A

D

-1 -C

D

-1 -B

D

-1 -B

D

-1 -C

D

-1 -A

D

-1 -A

D

-1 -C

D

-1 -B

C1-36-AP-B

C1-34-AP-A

C -3

-A

1U-162B-C1 U

-1 B

-A

D

-1 -C

D

-1 -B

D

-1 -A

1D-118-B

D

-1 -A

D

-1 -A 1D-125-B

1D-113-A

C1-36-AP-C

1D-108-B

1D-108-C

1D-108-A

1D-108-D

D

-1 -A

D

-1 -B

U

-1 -C

U

-1 -A

U

-1 -B

1D-177-C

D

-1 -A

D

-1 -B

1D-115-AP-A

D

-1 -E

D

-1 -D

D

-1 -C

D

-1 -B

D

-1 -A

D

-1 -D

D

-1 -C

D

-1 -A

D

-1 -B

D

-1 -A

D

-1 -D

D

-1 -E

D

-1 -B

D

-1 -C

1D-109-AP-A

1D-109-A

1D-109-B1 D

-1 -C

D

-1 -D

1D-109-E

D

-1 -F

D

-G

D

-1 -H

D

-1 -A

D

-1 -B

D

-1 -C

U

-1 B

-B 1U-162B-AP-A

D

-1 -C

D

-1 -B

D

-1 -A

1D-105-AP-A

D

-1 -C

D

-1 -A

D

-1 -B

D

-1 -C

D

-1 -A

D

-1 -B

D

-1 -B

1D-101-A

D

-1 -A

C1-31-AP-A

C -3

-A

C -3

-B

C -3

-C

C1-31-D

C1-31-E

C1-31-F

1C-104-A

1C-104-B

C1-31-G

C1-31-H

C1-31-AP-B

C1-30-AP-A

D

-1 -A

D

-1 -B

D

-1 -A

D

-1 -A

D

-1 -B

C

-1 -A

C

-1 -B

N O

D A

T A

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

N O

D A

T A

N O

D A

T A

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

70T-412

C3 70T-412

C7

TELECOM

ROOM

(CYAN-STACK)

1C-1061C-106

1U-1621U-162

1U-162A1U-162A

1U-162B1U-162B C1-34AC1-34A

1D-121A1D-121A

1D-1211D-121

1D-1221D-122C1-34C1-34

1D-1171D-117

1D-1151D-115

1D-1141D-114

1D-1161D-116

1D-1181D-118

1D-1231D-123

1D-122A1D-122A1D-115A1D-115A

C1-36C1-36

C1-32C1-32 1D-116A1D-116A

1D-1251D-125

1D-1241D-124

1D-124A1D-124A

1D-125A1D-125A

1D-112A1D-112A

1D-1131D-113

1D-113A1D-113A

1D-1111D-111

1D-1121D-112

1D-1091D-109

C1-38C1-38

1D -1

1D

-1

1D-1261D-126

1D-1271D-127

1D-1301D-130

1D-1321D-132

1D-127A1D-127A

1D-1281D-128

1D-1081D-108

1D-1291D-129

1D-1061D-106 1D-1311D-131

1D-1331D-1331D-135A1D-135A

C1-31C1-31

1D-105A1D-105A 1D-1051D-105

1D-1071D-107

1D-1031D-103

1D-1021D-102

1D-1341D-134

1D-1351D-135

1D-132A1D-132A

1D-134A1D-134A

C1-30C1-30

1D -1

A

1D -1

A

1D-1011D-101

1D-136A1D-136A

1C-1051C-105

1D-102A1D-102A

1D-107A1D-107A

1C-1041C-104

C1-28C1-28 C1-29C1-29

1C-1011C-101

1C-1211C-121

TOILET

1C-1031C-103 C1-37C1-37

C1-40C1-40 on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

GENERAL NOTES

KEYNOTES

A

B D

TRUE NORTH

PLAN NORTH

E F

G

H

J

K

L

M

N

C

KEYPLANA/E:

TRIPLE C - The A/E Group

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

As indicated

B

IM

/6

-2

-7

E

H R

M I n fr a s tr u c tu re U p g ra d e s M

P L S

V A

M C

/6 -2

-7

.M

E H

R M

.M E

P .B

.L

.r v t

/6

/2

:3 :2

P

M

11/05/2021 M. Perkins G. Weaver

618-21-700

1383 - 70T-101C

TELECOMMUNICATION PLAN - FIRST LEVEL

AREA C

1 Veterans Drive, Minneapolis, MN 55417

B70

EHRM INFRASTRUCTURE

UPGRADESFINAL BID DOCUMENTS

A. PROPERLY FIRE STOP AND SEAL ALL PENETRATIONS THROUGH WALLS,

FLOORS, CEILINGS, AND ROOF AS PER OWNER, CODE, AND AHJ.

B. PRIOR TO INSTALLATION OF CABLE TRAY COORDINATE LOCATIONS WITH ALL

OTHER TRADES AND PROVIDE COORDINATION DRAWINGS FOR REVIEW. ALL

NEW CABLE, CABLE TRAY, J HOOKS SHALL BE INDEPENDENTLY SUPPORTED &

NOT CAUSE ADDITIONAL LOAD ON OTHER SYSTEMS.

C. NOT ALL PARTS AND PIECES ARE SHOWN FOR A COMPLETE SYSTEM.

CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE END-TO-END

WARRANTEED SOLUTION FOR THE CABLING.

D. ALL CABLING TO BE PLENUM RATED THROUGHOUT THE BUILDING.

E. ALL COMMUNICATIONS AND WIRELESS ACCESS POINT CABLING TO MEET OR

EXCEED CATEGORY 6A STANDARDS.

F. SEE E-501 FOR DEVICE STANDARD MOUNTING HEIGHTS.

G. ALL CONDUITS FOR TELECOMMUNICATIONS OUTLETS SHALL BE STEEL THIN

WALL ELECTRICAL METALLIC TUBING (TYPE EMT) UNLESS OTHERWISE NOTED.

UNDER NO CIRCUMSTANCES SHALL FLEXIBLE CONDUIT BE USED FOR

PATHWAYS INDICATED ON THIS DRAWING. ALL CONDUITS ARE TO BE, AT A

MINIMUM, 1-1/4" TRADE SIZE, UNLESS OTHERWISE NOTED. ALL CONDUITS FOR

TELECOMMUNICATIONS OUTLETS ARE TO BE STUBBED TO NEAREST CABLE

TRAY. CONTRACTOR IS TO ENSURE THAT NO CONDUIT EXCEEDS 40% FILL. IF

EXISTING CONDUIT IS NOT LARGE ENOUGH TO SUPPORT NEW CAT 6A CABLE

TO REPLACE ALL EXISTING CIRCUITS ONE-FOR-ONE, CONTRACTOR SHALL

PROVIDE THE MAXIMUM ALLOWABLE NEW CAT 6A CIRCUITS TO REPLACE

EXISTING. THE ADDITIONAL NEW CIRCUITS TO COMPLETE THE ONE-FOR-ONE

REPLACEMENT SHALL BE PROVIDED AT THE NEAREST AVAILABLE DROP WITH

EXISTING CONDUIT CAPACITY.

H. ALL CONDUIT PATHWAYS SHALL BE PROVIDED WITH NYLON BUSHINGS TO

PROTECT CABLES, REGARDLESS OF WHETHER THEY TERMINATE IN A DEVICE

OR JUNCTION BOX.

I. TERMINATE, TEST, LABEL AND DOCUMENT ALL TELECOMMUNICATION CABLES.

J. CONTRACTOR SHALL AVOID ALL SYSTEMS SHUTDOWNS, INSTALL NEW

EQUIPMENT PRIOR TO THE RENOVATION OF EXISTING EQUIPMENT; PROVIDE

TEMPORARY UTILITIES AS REQUIRED TO MEET THIS REQUIREMENT.

K. THE DEMOLITION OF DEVICES SHALL INCLUDE ALL ASSOCIATED CABLING

BACK TO THE RACK.

L. LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL FOLLOWING ALL

STANDARDS AND REQUIREMENTS, SEE DETAIL SHEETS FOR ADDITIONAL

INFORMATION

M. CONTRACTOR SHALL PROVIDE TWO SETS OF LAMINATED FINAL

TELECOMMUNICATION ONE-LINE, RACK ELEVATION, AND CABLE SCHEDULE

DOCUMENTS. HANG ON THE WALL WITHIN THE TELECOM ROOM.

N. REFER TO T-600 SERIES SHEETS FOR PHOTO DOCUMENTATION OF EXISTING

CONDITIONS.

NOTE: NOT ALL KEYNOTES ARE USED

ON EACH SHEET

1. PROVIDE NEW TELECOMMUNICATIONS OUTLET IN EXISTING LOCATION WITH

EXISTING EMT STUB UP TO NEAREST ACCESSIBLE CEILING SPACE. SEE DETAILS

ON SHEET T-501 FOR ADDITIONAL INFORMATION.

2. EXISTING WIRELESS ACCESS POINT TO BE RETAINED AND REUSED. PROVIDE

NEW CABLING AND TELECOMMUNICATIONS OUTLET. REFER TO DETAILS ON

SHEET T-501 FOR ADDITIONAL INFORMATION.

3. PROVIDE NEW 4-POST RACK, PDU, UPS AND WIRE MANAGEMENT COMPONENTS

AS SHOWN ON T-500 SERIES AND T-600 SERIES SHEETS AND IN THE

SPECIFICATIONS. PHASE TO PROVIDE NEW RACK IN A TEMPORARY LOCATION

AND TRANSFER DATA CIRCUITS FROM THE EXISTING RACK TO THE NEW RACK.

PROVIDE TEMPORARY EXTRA LENGTH JUMPER CABLES TO EXISTING SWITCHES

AND OTHER DEVICES TO ENSURE UNINTERRUPTED SERVICE. ONCE ALL

EXISTING DATA CIRCUITS ARE RELOCATED TO NEW PATCH PANELS ON THE

NEW RACK AND ALL EXISTING DEVICES TO REMAIN ARE TRANSFERRED TO THE

NEW RACK, REMOVE THE EXISTING RACK AND INSTALL THE NEW RACKS IN THE

FINAL PERMANENT POSITION.

4. PROVIDE NEW VERTICAL WIRE MANAGEMENT SYSTEM, SEE SPECIFICATIONS

FOR ADDITIONAL INFORMATION.

5. EXISTING CABLING CONDUIT AND WIREWAYS ARE TO REMAIN AND BE

CAREFULLY PROTECTED IN PLACE. ALL EXISTING DEVICES ON THE EXISTING

RACK SHALL BE TRANSFERRED TO THE NEW SECOND LEVEL LOCATION ON THE

NEW RACK. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS SHOWING THE

PROPOSED NEW RACK ELEVATION AND PROVIDE A PHASING PLAN FOR

TRANSFERRING ALL EXISTING DEVICES TO REMAIN TO THE NEW RACKS.

6. PROVIDE NEW CABLE TRAY PER REQUIREMENTS LISTED IN CABLE TRAY

SCHEDULE. COORDINATE WITH EXISTING CONDITIONS AND SUBMIT

COORDINATION DRAWINGS FOR REVIEW PRIOR TO COMMENCING WORK.

COORDINATE FIXTURES WITH OVERHEAD TRAY. SEE T-500 SERIES SHEETS FOR

ADDITIONAL REQUIREMENTS. COORDINATE LIGHT FIXTURES WITH OVERHEAD

CABLE TRAY.

7. PROVIDE NEW IP ADDRESSABLE NETWORK CAMERA, POE+, PTZ, MOTION

SENSOR, AUTO-TRACKING, DOME WITH WALL MOUNT. BASIS OF DESIGN

WISENET XNP-6320. MOUNT AT 8’ – 6” A.F.F. TO TOP OF WALL BRACKET.

INTEGRATE CAMERA INTO EXISTING VMS. PROVIDE CONTROLLABILITY THROUGH

EXISTING IT NETWORK.

8. PROVIDE NEW DATA OUTLET, STUB-UP, AND BACK-BOX IN NEW LOCATION IN TR.

9. PROVIDE (2) STACKS OF (3)(6 TOTAL) 4” SPEED CONDUIT SLEEVE THROUGH

WALL ABOVE CEILING GRID FOR HORIZONTAL VOICE/DATA CABLING OR FIBER

WITH PLASTIC BUSHINGS ON BOTH ENDS TO PROTECT CABLES. FIRE CAULK

PENETRATION PER SPECIFICATIONS.

10. EXISTING CONDUIT THROUGH WALL OR FLOOR WITH OPTICAL CABLE TO BE

PROTECTED IN PLACE UNTIL NEW SPEED CONDUIT SLEEVE AND FIBER IS

INSTALLED. DEMOLISH EXISTING CONDUIT ONCE NEW SPEED CONDUIT SLEEVE

AND FIBER ARE OPERATIONAL. CONTRACTOR SHALL PROVIDE A PHASING PLAN

FOR TRANSFERRING FIBER.

11. EXISTING EQUIPMENT TO REMAIN, PROTECT-IN-PLACE.

12. EXISTING WALL MOUNTED FIBER SPLICE WITH MULTI-MODE OPTICAL CABLE TO

BE PROTECTED IN PLACE UNTIL NEW SPEED FIBER IS INSTALLED. DEMOLISH

EXISTING FIBER SPLICE ONCE NEW SPEED CONDUIT SLEEVE AND FIBER ARE

OPERATIONAL. CONTRACTOR SHALL PROVIDE A PHASING PLAN FOR

TRANSFERRING FIBER.

13. REMOVE DATA DEVICE AND RELOCATE, REPLACE CABLING WITH CAT6A MATCH

EXISTING CIRCUIT COUNT. PROVIDE NEW 1-1/4" CONDUIT AS INDICATED ON

T-601.

SCALE: 1" = 10'-0"

F6

TELECOMMUNICATION PLAN - FIRST

LEVEL AREA C

WAP

WAP WAP

WAP

WAP

WAP

WAP

WAP

WAP

WAP

PARTITION RATING GRAPHICS:

2 HR FIRE SHAFT

1 HR SMOKE BARRIER

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION:

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND

SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.

1 HR INCIDENTAL USE

C1-28-AP-A

C1-40-AP-A

C

-1 -A

C

-1 -B

C

-1 -C

1C-106-C

C

-1 -B

C

-1 -A

1C-106-D

1C-107-E

1C-107-D

1C-107-B

C

-1 -B

1C-108-A

C1-49-AP-A

1C-112-A

C1-49-AP-B

1C-115-AP-A

1C-115-A

C1-48-AP-A

C1-38-AP-A

1C-110-C

1C-110-A

C

-1 -B

C

-1 -A

C

-1 -B

1C-135-A

C

-1 -C

C1-39-AP-A

C1-41-C

C1-41-E

C1-41-OC1-41-P

C -4

-M

C -4

-F

C -4

-G

E

-1 -B

1E-104-C

E

-1 -A

C1-41-AP-A

E

-1 A

-A

C1-43-AP-A

C1-43-AP-B

1E-122A-A 1E-119A-B1E-119A-A

C1-46-AP-A

1C-107-C

1C-108-A

C

-1 -A

C

-1 -B

C -4

-L

C -4

-N

C -4

-K

C -4

-J

C -4

-H

C -4

-A

C -4

-B

C1-41-D 1E-104-D

1E-104-A

E

-1 -B

1E-106-C

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATANO DATA

NO DATA NO DATA

NO DATA

NO DATA

NO DATA NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA

NO DATA

NO DATA

NO DATA NO DATA NO DATA

NO DATA

NO DATA

NO DATANO DATA

NO DATA

NO DATA

NO DATA

N O

D A

T A

N O

D A

T A

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATANO DATANO DATANO DATANO DATANO DATANO DATA

NO DATA

NO DATA NO DATA NO DATA

NO DATA

70T-412

C3

70T-412

C7

B H

-1 A

-C A

M -0

TELECOM

ROOM

(CYAN-STACK)

1C-1061C-106

SHARED

OFFICE

1C-1071C-107

1D -1

A

1D -1

A

1D-136A1D-136A

1C-1051C-105

1C-1041C-104

C1-50C1-50

1C-1201C-120

C1-49C1-49

DD

1C-1121C-112

M7M7

1C-1151C-115

C1-28C1-28 C1-29C1-29

1C-1011C-101

1C-1211C-121

TOILET

1C-1031C-103

1C-1111C-111

C1-48AC1-48A

C1-37C1-37

1C-1081C-108

C1-48C1-48

1C-1161C-116

1C-1171C-117

1C-1181C-118

1C-1191C-119

1C-114B1C-114B

1C-114D1C-114D

1C-114C1C-114C

1C-114A1C-114A

C1-40C1-40

1E-101A1E-101A

1E-1011E-101 1E-1031E-103 1E-1051E-105

1E-103A1E-103A 1E-105A1E-105A

1E-1071E-107 1E-1101E-110

1E-110A1E-110A

1E-1121E-112 1E-1131E-113 1E-1141E-114

1E-1151E-115

1E-113A1E-113A

1E-115A1E-115A

1E-1161E-116

C1-45C1-45

C1-44C1-44

??1E-1111E-111

1E-111A1E-111A

1E-1091E-109

1E-1231E-123 1E-120A1E-120A

1E-123A1E-123A

C1-43C1-43

C1-42C1-42

C1-46C1-46

TELECOM

ROOM

1E-117C1E-117C

1E-1171E-117

1E-117A1E-117A

ELECTRICAL

ROOM

1E-117B1E-117B

1E-1181E-118

1E-118A1E-118A

1E-1191E-1191E-1211E-121

1E-119A1E-119A

1E-1221E-122

1E-122A1E-122A

1E-1241E-1241E-1251E-125

1E-125A1E-125A

1E-1281E-128

C1-47C1-47

1E-1261E-126

1E-1081E-108

1E-1271E-127

1E-1061E-106

1E -1

1E

-1

1E-1021E-102

1E-1311E-131

C1-41C1-41

1E-1301E-130

1E-130A1E-130A

1E-1321E-132

1E-132A1E-132A

1E-1331E-133

1E-1291E-129

1E-1341E-134

C1-39C1-39

1C-1351C-135

1E-134A1E-134A

1C -1

1C

-1

1F-1361F-136

1F-136A1F-136A

1S-41S-4

ELECTRIC

ROOM

1D-1741D-174

C1-202C1-202

1C-107-A on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

GENERAL NOTES

KEYNOTES

A

B D

TRUE NORTH

PLAN NORTH

E F

G

H

J

K

L

M

N

C

KEYPLANA/E:

TRIPLE C - The A/E Group

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

As indicated

B

IM

/6

-2

-7

E

H R

M I n fr a s tr u c tu re U p g ra d e s M

P L S

V A

M C

/6 -2

-7

.M

E H

R M

.M E

P .B

.L

.r v t

/6

/2

:3 :3

P

M

11/05/2021 M. Perkins G. Weaver

618-21-700

1383 - 70T-101D

TELECOMMUNICATION PLAN - FIRST LEVEL

AREA D

1 Veterans Drive, Minneapolis, MN 55417

B70

EHRM INFRASTRUCTURE

UPGRADESFINAL BID DOCUMENTS

A. PROPERLY FIRE STOP AND SEAL ALL PENETRATIONS THROUGH WALLS,

FLOORS, CEILINGS, AND ROOF AS PER OWNER, CODE, AND AHJ.

B. PRIOR TO INSTALLATION OF CABLE TRAY COORDINATE LOCATIONS WITH ALL

OTHER TRADES AND PROVIDE COORDINATION DRAWINGS FOR REVIEW. ALL

NEW CABLE, CABLE TRAY, J HOOKS SHALL BE INDEPENDENTLY SUPPORTED &

NOT CAUSE ADDITIONAL LOAD ON OTHER SYSTEMS.

C. NOT ALL PARTS AND PIECES ARE SHOWN FOR A COMPLETE SYSTEM.

CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE END-TO-END

WARRANTEED SOLUTION FOR THE CABLING.

D. ALL CABLING TO BE PLENUM RATED THROUGHOUT THE BUILDING.

E. ALL COMMUNICATIONS AND WIRELESS ACCESS POINT CABLING TO MEET OR

EXCEED CATEGORY 6A STANDARDS.

F. SEE E-501 FOR DEVICE STANDARD MOUNTING HEIGHTS.

G. ALL CONDUITS FOR TELECOMMUNICATIONS OUTLETS SHALL BE STEEL THIN

WALL ELECTRICAL METALLIC TUBING (TYPE EMT) UNLESS OTHERWISE NOTED.

UNDER NO CIRCUMSTANCES SHALL FLEXIBLE CONDUIT BE USED FOR

PATHWAYS INDICATED ON THIS DRAWING. ALL CONDUITS ARE TO BE, AT A

MINIMUM, 1-1/4" TRADE SIZE, UNLESS OTHERWISE NOTED. ALL CONDUITS FOR

TELECOMMUNICATIONS OUTLETS ARE TO BE STUBBED TO NEAREST CABLE

TRAY. CONTRACTOR IS TO ENSURE THAT NO CONDUIT EXCEEDS 40% FILL. IF

EXISTING CONDUIT IS NOT LARGE ENOUGH TO SUPPORT NEW CAT 6A CABLE

TO REPLACE ALL EXISTING CIRCUITS ONE-FOR-ONE, CONTRACTOR SHALL

PROVIDE THE MAXIMUM ALLOWABLE NEW CAT 6A CIRCUITS TO REPLACE

EXISTING. THE ADDITIONAL NEW CIRCUITS TO COMPLETE THE ONE-FOR-ONE

REPLACEMENT SHALL BE PROVIDED AT THE NEAREST AVAILABLE DROP WITH

EXISTING CONDUIT CAPACITY.

H. ALL CONDUIT PATHWAYS SHALL BE PROVIDED WITH NYLON BUSHINGS TO

PROTECT CABLES, REGARDLESS OF WHETHER THEY TERMINATE IN A DEVICE

OR JUNCTION BOX.

I. TERMINATE, TEST, LABEL AND DOCUMENT ALL TELECOMMUNICATION CABLES.

J. CONTRACTOR SHALL AVOID ALL SYSTEMS SHUTDOWNS, INSTALL NEW

EQUIPMENT PRIOR TO THE RENOVATION OF EXISTING EQUIPMENT; PROVIDE

TEMPORARY UTILITIES AS REQUIRED TO MEET THIS REQUIREMENT.

K. THE DEMOLITION OF DEVICES SHALL INCLUDE ALL ASSOCIATED CABLING

BACK TO THE RACK.

L. LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL FOLLOWING ALL

STANDARDS AND REQUIREMENTS, SEE DETAIL SHEETS FOR ADDITIONAL

INFORMATION

M. CONTRACTOR SHALL PROVIDE TWO SETS OF LAMINATED FINAL

TELECOMMUNICATION ONE-LINE, RACK ELEVATION, AND CABLE SCHEDULE

DOCUMENTS. HANG ON THE WALL WITHIN THE TELECOM ROOM.

N. REFER TO T-600 SERIES SHEETS FOR PHOTO DOCUMENTATION OF EXISTING

CONDITIONS.

NOTE: NOT ALL KEYNOTES ARE USED

ON EACH SHEET

1. PROVIDE NEW TELECOMMUNICATIONS OUTLET IN EXISTING LOCATION WITH

EXISTING EMT STUB UP TO NEAREST ACCESSIBLE CEILING SPACE. SEE DETAILS

ON SHEET T-501 FOR ADDITIONAL INFORMATION.

2. EXISTING WIRELESS ACCESS POINT TO BE RETAINED AND REUSED. PROVIDE

NEW CABLING AND TELECOMMUNICATIONS OUTLET. REFER TO DETAILS ON

SHEET T-501 FOR ADDITIONAL INFORMATION.

3. PROVIDE NEW 4-POST RACK, PDU, UPS AND WIRE MANAGEMENT COMPONENTS

AS SHOWN ON T-500 SERIES AND T-600 SERIES SHEETS AND IN THE

SPECIFICATIONS. PHASE TO PROVIDE NEW RACK IN A TEMPORARY LOCATION

AND TRANSFER DATA CIRCUITS FROM THE EXISTING RACK TO THE NEW RACK.

PROVIDE TEMPORARY EXTRA LENGTH JUMPER CABLES TO EXISTING SWITCHES

AND OTHER DEVICES TO ENSURE UNINTERRUPTED SERVICE. ONCE ALL

EXISTING DATA CIRCUITS ARE RELOCATED TO NEW PATCH PANELS ON THE

NEW RACK AND ALL EXISTING DEVICES TO REMAIN ARE TRANSFERRED TO THE

NEW RACK, REMOVE THE EXISTING RACK AND INSTALL THE NEW RACKS IN THE

FINAL PERMANENT POSITION.

4. PROVIDE NEW VERTICAL WIRE MANAGEMENT SYSTEM, SEE SPECIFICATIONS

FOR ADDITIONAL INFORMATION.

5. EXISTING CABLING CONDUIT AND WIREWAYS ARE TO REMAIN AND BE

CAREFULLY PROTECTED IN PLACE. ALL EXISTING DEVICES ON THE EXISTING

RACK SHALL BE TRANSFERRED TO THE NEW SECOND LEVEL LOCATION ON THE

NEW RACK. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS SHOWING THE

PROPOSED NEW RACK ELEVATION AND PROVIDE A PHASING PLAN FOR

TRANSFERRING ALL EXISTING DEVICES TO REMAIN TO THE NEW RACKS.

6. PROVIDE NEW CABLE TRAY PER REQUIREMENTS LISTED IN CABLE TRAY

SCHEDULE. COORDINATE WITH EXISTING CONDITIONS AND SUBMIT

COORDINATION DRAWINGS FOR REVIEW PRIOR TO COMMENCING WORK.

COORDINATE FIXTURES WITH OVERHEAD TRAY. SEE T-500 SERIES SHEETS FOR

ADDITIONAL REQUIREMENTS. COORDINATE LIGHT FIXTURES WITH OVERHEAD

CABLE TRAY.

7. PROVIDE NEW IP ADDRESSABLE NETWORK CAMERA, POE+, PTZ, MOTION

SENSOR, AUTO-TRACKING, DOME WITH WALL MOUNT. BASIS OF DESIGN

WISENET XNP-6320. MOUNT AT 8’ – 6” A.F.F. TO TOP OF WALL BRACKET.

INTEGRATE CAMERA INTO EXISTING VMS. PROVIDE CONTROLLABILITY THROUGH

EXISTING IT NETWORK.

8. PROVIDE NEW DATA OUTLET, STUB-UP, AND BACK-BOX IN NEW LOCATION IN TR.

9. PROVIDE (2) STACKS OF (3)(6 TOTAL) 4” SPEED CONDUIT SLEEVE THROUGH

WALL ABOVE CEILING GRID FOR HORIZONTAL VOICE/DATA CABLING OR FIBER

WITH PLASTIC BUSHINGS ON BOTH ENDS TO PROTECT CABLES. FIRE CAULK

PENETRATION PER SPECIFICATIONS.

10. EXISTING CONDUIT THROUGH WALL OR FLOOR WITH OPTICAL CABLE TO BE

PROTECTED IN PLACE UNTIL NEW SPEED CONDUIT SLEEVE AND FIBER IS

INSTALLED. DEMOLISH EXISTING CONDUIT ONCE NEW SPEED CONDUIT SLEEVE

AND FIBER ARE OPERATIONAL. CONTRACTOR SHALL PROVIDE A PHASING PLAN

FOR TRANSFERRING FIBER.

11. EXISTING EQUIPMENT TO REMAIN, PROTECT-IN-PLACE.

12. EXISTING WALL MOUNTED FIBER SPLICE WITH MULTI-MODE OPTICAL CABLE TO

BE PROTECTED IN PLACE UNTIL NEW SPEED FIBER IS INSTALLED. DEMOLISH

EXISTING FIBER SPLICE ONCE NEW SPEED CONDUIT SLEEVE AND FIBER ARE

OPERATIONAL. CONTRACTOR SHALL PROVIDE A PHASING PLAN FOR

TRANSFERRING FIBER.

13. REMOVE DATA DEVICE AND RELOCATE, REPLACE CABLING WITH CAT6A MATCH

EXISTING CIRCUIT COUNT. PROVIDE NEW 1-1/4" CONDUIT AS INDICATED ON

T-601.

SCALE: 1" = 10'-0"

F2

TELECOMMUNICATION PLAN - FIRST

LEVEL AREA D

WAP

WAP

WAP

WAP

WAP

WAP WAP

WAP PARTITION RATING GRAPHICS:

2 HR FIRE SHAFT

1 HR SMOKE BARRIER

SMOKE PARTITION (NON RATED)

NON RATED

PARTITION RATING GRAPHIC DESIGNATION:

PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND

SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.

1 HR INCIDENTAL USE

F

-1 -A

F

-1 -A

F

-1 -A

F

-1 -A

F

-1 -A

F

-1 -A

F

-1 -A

F

-1 -A

F

-1 -A

F

-1 -A

F

-1 -E

F

-1 -D

F

-1 -C

F

-1 -F

F

-1 -G

F

-1 -H

1F-120-A

1F-120-B 1F-120A-A

1F-118-B

1F-118-A

C -5

-A

C1-55-AP-A

C1-55A-B

C1-55A-A

1F-122-A

1F-113-AP-A

1F-125-A

C1-54-AP-A

1F-108-D

1F-108-A

1F-108-B

1F-108-C

1F-106-A

F

-1 -B

C -5

-A

C -5

-C

C -5

-D

C1-52-E

C1-52-F

C -5

-G

C -5

-H

C -5

-J

C1-52-AP-C

C -5

-B

C1-52-K

C1-52-M

C1-52-L

C1-52-AP-A

C1-52-AP-B

F

-1 -A

F

-1 -A

F

-1 -A

F

-1 -A

F

-1 -A

F

-1 -A

F

-1 -A

F

-1 -A

F

-1 -A

F

-1 -A

C -5

-A

P -B

C -5

-A

P -C

C1-56-AP-A

NO DATA NO DATA

NO DATA

NO DATA

N O

D A

T A

N O

D A

T A

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

NO DATA

C1-51-AP-B

C1-50C1-50

1C-1201C-120

1C-1151C-115

1C-114D1C-114D

1C-114C1C-114C 1E-1341E-134

1C -1

1C

-1

1F-1361F-136

1F-136A1F-136A

1F-1021F-102 1F-1351F-135

1F-1341F-134

1F-1321F-132

1F-1301F-130

1F-132A1F-132A

1F-134A1F-134A

C1-52C1-52

1F-102A1F-102A

1F-105A1F-105A

1F-1031F-103

1F-1051F-105

1F-1071F-107

1F-1091F-109

1F-1121F-112

1F-107A1F-107A

1F-1041F-1041F-1331F-133

1F-1311F-131

1F-1061F-106

1F-1081F-108 1F-1291F-129

1F-127A1F-127A

1F-1271F-127

1F-1281F-128 1F-1101F-110

C1-54C1-54

1F-1261F-126

C1-55AC1-55A

1F-125A1F-125A

1F-1111F-111

1F-1251F-125

1F-113A1F-113A 1F-112A1F-112A

1F-1141F-114

C1-53C1-53 1F-124A1F-124A

1F-1241F-124

1F-1231F-123

1F-1211F-121

1F-1131F-113

1F-122A1F-122A

1F-121A1F-121A

C1-55C1-55

1F-1151F-115

1F-1161F-116

1F-115A1F-115A

1F-1171F-1171F-117A1F-117A

1F-1181F-118 C1-56C1-561F-120A1F-120A

1F-1201F-120

C1-202C1-202

C1-204C1-204

1L-1161L-116

C1-56AC1-56A

ELECTRIC

ROOM

1F-119A1F-119ATELECOM

ROOM

1F-119B1F-119B

1L-1171L-117

1L-1181L-118

C1-58C1-58

C1-57BC1-57B

STAIRSTAIR

1F-1221F-122 on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

GENERAL NOTES

KEYNOTES

A

B D

TRUE NORTH

PLAN NORTH

E F

G

H

J

K

L

M

N

C

KEYPLANA/E:

TRIPLE C - The A/E Group

2508 29th Avenue NE

Minneapolis, MN 55418

(612) 355-1251

Mat Perkins

As indicated

B

IM

/6

-2

-7

E

H R

M I n fr a s tr u c tu re U p g ra d e s M

P L S

V A

M C

/6 -2

-7

.M

E H

R M

.M E

P .B

.L

.r v t

/6

/2

:3 :4

P

M

11/05/2021 M. Perkins G. Weaver

618-21-700

1383 - 70T-101E

TELECOMMUNICATION PLAN - FIRST LEVEL

AREA E

1 Veterans Drive, Minneapolis, MN 55417

B70

EHRM INFRASTRUCTURE

UPGRADESFINAL BID DOCUMENTS

A. PROPERLY FIRE STOP AND SEAL ALL PENETRATIONS THROUGH WALLS,

FLOORS, CEILINGS, AND ROOF AS PER OWNER, CODE, AND AHJ.

B. PRIOR TO INSTALLATION OF CABLE TRAY COORDINATE LOCATIONS WITH ALL

OTHER TRADES AND PROVIDE COORDINATION DRAWINGS FOR REVIEW. ALL

NEW CABLE, CABLE TRAY, J HOOKS SHALL BE INDEPENDENTLY SUPPORTED &

NOT CAUSE ADDITIONAL LOAD ON OTHER SYSTEMS.

C. NOT ALL PARTS AND PIECES ARE SHOWN FOR A COMPLETE SYSTEM.

CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE END-TO-END

WARRANTEED SOLUTION FOR THE CABLING.

D. ALL CABLING TO BE PLENUM RATED THROUGHOUT THE BUILDING.

E. ALL COMMUNICATIONS AND WIRELESS ACCESS POINT CABLING TO MEET OR

EXCEED CATEGORY 6A STANDARDS.

F. SEE E-501 FOR DEVICE STANDARD MOUNTING HEIGHTS.

G. ALL CONDUITS FOR TELECOMMUNICATIONS OUTLETS SHALL BE STEEL THIN

WALL ELECTRICAL METALLIC TUBING (TYPE EMT) UNLESS OTHERWISE NOTED.

UNDER NO CIRCUMSTANCES SHALL FLEXIBLE CONDUIT BE USED FOR

PATHWAYS INDICATED ON THIS DRAWING. ALL CONDUITS ARE TO BE, AT A

MINIMUM, 1-1/4" TRADE SIZE, UNLESS OTHERWISE NOTED. ALL CONDUITS FOR

TELECOMMUNICATIONS OUTLETS ARE TO BE STUBBED TO NEAREST CABLE

TRAY. CONTRACTOR IS TO ENSURE THAT NO CONDUIT EXCEEDS 40% FILL. IF

EXISTING CONDUIT IS NOT LARGE ENOUGH TO SUPPORT NEW CAT 6A CABLE

TO REPLACE ALL EXISTING CIRCUITS ONE-FOR-ONE, CONTRACTOR SHALL

PROVIDE THE MAXIMUM ALLOWABLE NEW CAT 6A CIRCUITS TO REPLACE

EXISTING. THE ADDITIONAL NEW CIRCUITS TO COMPLETE THE ONE-FOR-ONE

REPLACEMENT SHALL BE PROVIDED AT THE NEAREST AVAILABLE DROP WITH

EXISTING CONDUIT CAPACITY.

H. ALL CONDUIT PATHWAYS SHALL BE PROVIDED WITH NYLON BUSHINGS TO

PROTECT CABLES, REGARDLESS OF WHETHER THEY TERMINATE IN A DEVICE

OR JUNCTION BOX.

I. TERMINATE, TEST, LABEL AND DOCUMENT ALL TELECOMMUNICATION CABLES.

J. CONTRACTOR SHALL AVOID ALL SYSTEMS SHUTDOWNS, INSTALL NEW

EQUIPMENT PRIOR TO THE RENOVATION OF EXISTING EQUIPMENT; PROVIDE

TEMPORARY UTILITIES AS REQUIRED TO MEET THIS REQUIREMENT.

K. THE DEMOLITION OF DEVICES SHALL INCLUDE ALL ASSOCIATED CABLING

BACK TO THE RACK.

L. LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL FOLLOWING ALL

STANDARDS AND REQUIREMENTS, SEE DETAIL SHEETS FOR ADDITIONAL

INFORMATION

M. CONTRACTOR SHALL PROVIDE TWO SETS OF LAMINATED FINAL

TELECOMMUNICATION ONE-LINE, RACK ELEVATION, AND CABLE SCHEDULE

DOCUMENTS. HANG ON THE WALL WITHIN THE TELECOM ROOM.

N.