618-21-700.MEHRM.FINAL.B70.20220506Part-18.pdf
PDF 14 MB Posted
- Solicitation number
- 36C77622R0045
About this file
This document describes a federal contract opportunity for construction design and infrastructure upgrades at the Minneapolis VA Medical Center. The project involves building infrastructure to support the nationally mandated Electronic Health Record Modernization project, including constructing a new server room on the hospital roof. The solicitation will be issued as a Request for Proposal evaluated according to FAR Parts 15, 19, and 36. It is advertised as a total Service-Disabled Veteran-Owned Small Business set-aside, with proposals due to the Department of Veterans Affairs by April 29th, 2022. The period of performance is approximately 450 calendar days from issuance of the notice to proceed. The magnitude of construction is estimated between $20-50 million.
View the file
Other files
Show 40 more
Latest 50 of 80 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WAP
WAP WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
PARTITION RATING GRAPHICS:
2 HR FIRE SHAFT
1 HR SMOKE BARRIER
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION:
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND
SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.
1 HR INCIDENTAL USE
C1-23-C
C1-23-B
C1-22-A
C1-23-A
C -2
-D
C -2
-E
C -2
-B
C1-22-AP-A
1U-152-AP-A
C1-35-AP-A
C1-22-AP-B
1D-120-AP-A
4-AP-A
1U-156-D
1U-156-E
1U-156-AP-A
1U-156-A
U
-1 -B
U
-1 -C
1U-151-A 1U-151-B
1U-151-C
1U-149-A1U-147-A
1U-147-AP-A
1U-146-C
1U-146-B
1U-146-A1U-116-E
1U-116-A
1U-116-B 1U-116-C
1U-116-D
1D-120-A
U
-1 -A
U
-1 -B
U
-1 -A
1U-114-AP-A
U
-1 -B
U
-1 -A
1U-110-A
U
-1 -A
C1-12-AP-A
U
-1 -A 1U-101-B
1U-101-C
U
-1 -E
U
-1 -D
1U-101-F
1U-101-G
1U-101-H
1U-101-J
1U-101-K
1U-101-L
C1-4-AP-A
C1-3-AP-A
C1-3-AP-B
C1-3-AP-C
U
-1 -B
U
-1 -C
U
-1 -D
1U-100-A
1U-133-B
1U-133-A
1U-131-AP-A
1U-131-A
U
-1 -A
U
-1 -A
U
-1 -A
U
-1 -A
U
-1 -B
1U-122-A
U
-1 -B
U
-1 -C
C1-13-AP-A
C1-12A-AP-A
1U-144-A
U
-1 -A
U
-1 -A
1U-137-A
1U-136-A
1U-123-A
1U-124-B
1U-124-A
1U-125-A
1U-143-A
1U-143-B
U
-1 -A 1U-134-B
1U-134-E1U-134-F
1U-159-A
1U-139-A
1U-139-AP-A
C1-21-AP-A
C1-17-AP-A
C1-16-A
C -1
-B
C -1
-C
C -1
-D
C1-24-AP-B
C1-24-AP-A
C1-15-AP-A
C1-15-A
C1-15-AP-B
1S-134-A
1S-134-B
S
-1 -C
1S-134-D
1S-134-AP-A
1S-134-E
1S-134-AP-B
S
-1 -A
S
-1 -C
S
-1 -B
S
-1 -A
C1-5A-A
C1-186-AP-A
S
-1 -A
S
-1 -A
S
-1 -A
1S-118-D
1S-118-C
1S-118-B
S
-1 -A
1S-119-B
1S-119-A
1S-119-C
1S-119-D
1S-119-E
1S-119-F
1S-125-AP-A
1S-120-D
1S-120-A
1S-120-B
1S-120-C
C1-187-AP-A
1S-114A-A
1S-114A-B1S-114A-C 1S-114A-D 1S-114A-E 1S-114A-F
1S-114A-G
S
-1 -A
1S-121-C 1S-121-B
S
-1 -F
S
-1 -E 1S-121-D
1S-121-G
1S-121-H 1S-121-J 1S-121-K
1S-121-L 1S-121-M
1S-121-N
1S-121-R 1S-121-Q 1S-121-P 1S-121-O
1S-121-AP-A
1S-121A-B
1S-121A-A
S
-1 A
-D
S
-1 A
-C
S
-1 A
-E
1U-107-B
1U-107-A 1U-106-A
1U-106-B
1U-105-B 1U-105-A
1U-105-AP-A
1U-102-A
1U-100B-C
1U-100B-A
1U-100B-B
U
-1 A
-A
1S-129-A
1S-127A-A
1S-127-B
1S-127-C
1S-127-AP-A
C1-24-AP-C
C -2
-B
C -2
-A
C1-25-A C1-25-J
C1-25-H
C -2
-G
C1-25-E
R
-2 -B
R
-2 -A
1R-250-C
1R-250-D
1R-250-E
1R-250-F
1R-250-G
U
-1 -A
1U-150-A
1U-150-B
1U-134-D
1U-134-C
S
-1 -A
KEYPAD
K E
Y P
A D
S
-1 -B
S
-1 -B
1S-125-A
1S-125-B
1S-127-A
1S-125-C
1S-125-E
1S-125-D
1R-250-AP-A
1R-250-AP-B
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATANO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATANO DATA NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA70T-411
F5
70T-411
F7
1U-104-CAM-01
TELECOM
ROOM
(GREEN-STACK)
1U-1041U-104
C1-3C1-3
C1-2C1-2
C1-1C1-1
CC
C1-4C1-4
1U-1001U-100
1U-100A1U-100A
C1-6C1-6
1S-1341S-134
C1-186C1-186
C1-2AC1-2A
1U-1051U-105
1U-1061U-106 1U-1071U-107 1U-1081U-108 1U-1101U-110
C1-12C1-12
1U-1011U-101
1U-100B1U-100B 1U-101A1U-101A
1C-71C-7
1U-1331U-133
C1-14C1-14
1U-1321U-132
1U-1311U-131 1U-1291U-129 1U-1281U-128 1U-1271U-127 1U-1261U-126
1U-1221U-122 1U-1301U-130
1U-1201U-120
1U-130A1U-130A
1U-109A1U-109A
1U-1091U-109 1U-1131U-1131U-1121U-112
1U-1191U-119
C1-13C1-13
1U-1111U-111
1U-1141U-114
1U-1151U-115
1U-1161U-116
C1-12AC1-12A
1U-1171U-117 1U-1441U-144
1U-1421U-142
1U-1181U-118
1U-1211U-121 1U-1381U-138
1U-1371U-1371U-1231U-123
1U-1241U-124 1U-1361U-136
1U-1251U-125
1U-1351U-135
C1-15C1-15
1S-1361S-136
C1-5aC1-5a 1S-1381S-138 1S-1291S-129
1S-1301S-130
1S-1311S-131 1616
1S-1331S-133
1S-126A1S-126A
1S-1321S-132
1S-1261S-126
1S-1251S-125 1S-1271S-127
1S-127A1S-127A
1S-127B1S-127B
1S-121A1S-121A
C1-187C1-187
1S-1211S-121
1S-114A1S-114A
1S-125A1S-125A
1S-1201S-120
1S-1191S-119
1S-1181S-1181S-1171S-1171S-1161S-1161S-1151S-115
1S-1351S-135 1S-1371S-137
C1-5C1-5 M-6M-6
1U-1461U-146
1U-1471U-147 1U-1491U-149
1U-1511U-151
1S-127H1S-127H
1S-91S-9
C1-20AC1-20A
C1-20C1-20
1U-1431U-143 1U-1481U-148 1U-1501U-150
C1-21C1-21
1U-1551U-1551U-1401U-140
C1-19C1-19
1U -1
1U
-1
1U-1591U-159
1U-1581U-158
1U-1571U-157
1U-1561U-156
ELECTRIC
ROOM
1U-1531U-153
TELECOM
ROOM
1U-1521U-152
C1-23C1-23C1-17C1-17
C1-16C1-16
C1-24C1-24
1D-1201D-120
C1-22C1-22
1D-120A1D-120A
ELECTRIC
ROOM
1D-120B1D-120B
TELECOM
ROOM
1D-120C1D-120C
C1-35C1-35
C1-167C1-167
1R-2501R-250
1S-1121S-112
1S-1001S-100
1S -1
1S
-1
1S-1071S-107
1S-1091S-109
C1-191C1-191
1S-1231S-123
1S-1101S-110
1S-1061S-106
1U-1621U-162
1U-162A1U-162A
1U-162B1U-162B C1-34AC1-34A
1D-121A1D-121A
1D-1211D-121
1D-1221D-122C1-34C1-34
1D-1171D-117
1D-1151D-115
1D-1141D-114
1D-1161D-116
1D-1181D-118
1D-1231D-123
1D-122A1D-122A1D-115A1D-115A
C1-36C1-36
C1-32C1-32 1D-116A1D-116A
1D-1251D-125
1D-1241D-124
1D-124A1D-124A
1D-125A1D-125A
1D-112A1D-112A
1D-1131D-113
1D-113A1D-113A
1D-1111D-111
1D-1121D-112
1D-1091D-109
C1-38C1-38
1D -1
1D
-1
1D-1261D-126
1D-1271D-127
1D-1301D-130
1D-1321D-132
1D-127A1D-127A
1D-1281D-128
1D-1081D-108
1D-1291D-129
1D-1061D-106 1D-1311D-131
1D-1071D-107
1D-107A1D-107A
1T-1051T-105
ELECTRIC
ROOM
1T-1031T-103
TELECOM
ROOM
1T-1041T-104
1R-1091R-109
1R-1081R-108
1S-1431S-143
1S-1441S-144
1S-21S-2
C1-194C1-194
C1-181C1-181
1V-1461V-146
1S-11S-1
ELECTRIC
ROOM
1T-1081T-108
TELECOM
ROOM
1T-1071T-107
M-5M-5
C1-185AC1-185A
C1-3AC1-3A
1V-1511V-151
C1-183AC1-183A
1V-152A1V-152A
1V-1521V-152
1V-151A1V-151A
1V-1501V-150 1V-1471V-147
C1-25C1-25
1U-1341U-134
1U-104-B
1U-104-C on e-ei gh th in ch o ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in es ne fo ot
REVISIONS DATE
General Notes:
GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO
THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED
BY THE VARIOUS SUBCONTRACTORS.
Approved: Division Chief
Issue Date Checked Drawn
DrawingNumber
Building Number
Project NumberDrawing Title Project Title
Location Drawing Scale
Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs
Office of Construction and Facilities Management
FULLY SPRINKLERED
Phase
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
GENERAL NOTES
KEYNOTES
A
B D
TRUE NORTH
PLAN NORTH
E F
G
H
J
K
L
M
N
C
KEYPLANA/E:
TRIPLE C - The A/E Group
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
As indicated
B
IM
/6
-2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e s M
P L S
V A
M C
/6 -2
-7
.M
E H
R M
.M E
P .B
.L
.r v t
/6
/2
:3 :5
P
M
11/05/2021 M. Perkins G. Weaver
618-21-700
1383 - 70T-101A
TELECOMMUNICATION PLAN - FIRST LEVEL
AREA A
1 Veterans Drive, Minneapolis, MN 55417
B70
EHRM INFRASTRUCTURE
UPGRADESFINAL BID DOCUMENTS
A. PROPERLY FIRE STOP AND SEAL ALL PENETRATIONS THROUGH WALLS,
FLOORS, CEILINGS, AND ROOF AS PER OWNER, CODE, AND AHJ.
B. PRIOR TO INSTALLATION OF CABLE TRAY COORDINATE LOCATIONS WITH ALL
OTHER TRADES AND PROVIDE COORDINATION DRAWINGS FOR REVIEW. ALL
NEW CABLE, CABLE TRAY, J HOOKS SHALL BE INDEPENDENTLY SUPPORTED &
NOT CAUSE ADDITIONAL LOAD ON OTHER SYSTEMS.
C. NOT ALL PARTS AND PIECES ARE SHOWN FOR A COMPLETE SYSTEM.
CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE END-TO-END
WARRANTEED SOLUTION FOR THE CABLING.
D. ALL CABLING TO BE PLENUM RATED THROUGHOUT THE BUILDING.
E. ALL COMMUNICATIONS AND WIRELESS ACCESS POINT CABLING TO MEET OR
EXCEED CATEGORY 6A STANDARDS.
F. SEE E-501 FOR DEVICE STANDARD MOUNTING HEIGHTS.
G. ALL CONDUITS FOR TELECOMMUNICATIONS OUTLETS SHALL BE STEEL THIN
WALL ELECTRICAL METALLIC TUBING (TYPE EMT) UNLESS OTHERWISE NOTED.
UNDER NO CIRCUMSTANCES SHALL FLEXIBLE CONDUIT BE USED FOR
PATHWAYS INDICATED ON THIS DRAWING. ALL CONDUITS ARE TO BE, AT A
MINIMUM, 1-1/4" TRADE SIZE, UNLESS OTHERWISE NOTED. ALL CONDUITS FOR
TELECOMMUNICATIONS OUTLETS ARE TO BE STUBBED TO NEAREST CABLE
TRAY. CONTRACTOR IS TO ENSURE THAT NO CONDUIT EXCEEDS 40% FILL. IF
EXISTING CONDUIT IS NOT LARGE ENOUGH TO SUPPORT NEW CAT 6A CABLE
TO REPLACE ALL EXISTING CIRCUITS ONE-FOR-ONE, CONTRACTOR SHALL
PROVIDE THE MAXIMUM ALLOWABLE NEW CAT 6A CIRCUITS TO REPLACE
EXISTING. THE ADDITIONAL NEW CIRCUITS TO COMPLETE THE ONE-FOR-ONE
REPLACEMENT SHALL BE PROVIDED AT THE NEAREST AVAILABLE DROP WITH
EXISTING CONDUIT CAPACITY.
H. ALL CONDUIT PATHWAYS SHALL BE PROVIDED WITH NYLON BUSHINGS TO
PROTECT CABLES, REGARDLESS OF WHETHER THEY TERMINATE IN A DEVICE
OR JUNCTION BOX.
I. TERMINATE, TEST, LABEL AND DOCUMENT ALL TELECOMMUNICATION CABLES.
J. CONTRACTOR SHALL AVOID ALL SYSTEMS SHUTDOWNS, INSTALL NEW
EQUIPMENT PRIOR TO THE RENOVATION OF EXISTING EQUIPMENT; PROVIDE
TEMPORARY UTILITIES AS REQUIRED TO MEET THIS REQUIREMENT.
K. THE DEMOLITION OF DEVICES SHALL INCLUDE ALL ASSOCIATED CABLING
BACK TO THE RACK.
L. LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL FOLLOWING ALL
STANDARDS AND REQUIREMENTS, SEE DETAIL SHEETS FOR ADDITIONAL
INFORMATION
M. CONTRACTOR SHALL PROVIDE TWO SETS OF LAMINATED FINAL
TELECOMMUNICATION ONE-LINE, RACK ELEVATION, AND CABLE SCHEDULE
DOCUMENTS. HANG ON THE WALL WITHIN THE TELECOM ROOM.
N. REFER TO T-600 SERIES SHEETS FOR PHOTO DOCUMENTATION OF EXISTING
CONDITIONS.
NOTE: NOT ALL KEYNOTES ARE USED
ON EACH SHEET
1. PROVIDE NEW TELECOMMUNICATIONS OUTLET IN EXISTING LOCATION WITH
EXISTING EMT STUB UP TO NEAREST ACCESSIBLE CEILING SPACE. SEE DETAILS
ON SHEET T-501 FOR ADDITIONAL INFORMATION.
2. EXISTING WIRELESS ACCESS POINT TO BE RETAINED AND REUSED. PROVIDE
NEW CABLING AND TELECOMMUNICATIONS OUTLET. REFER TO DETAILS ON
SHEET T-501 FOR ADDITIONAL INFORMATION.
3. PROVIDE NEW 4-POST RACK, PDU, UPS AND WIRE MANAGEMENT COMPONENTS
AS SHOWN ON T-500 SERIES AND T-600 SERIES SHEETS AND IN THE
SPECIFICATIONS. PHASE TO PROVIDE NEW RACK IN A TEMPORARY LOCATION
AND TRANSFER DATA CIRCUITS FROM THE EXISTING RACK TO THE NEW RACK.
PROVIDE TEMPORARY EXTRA LENGTH JUMPER CABLES TO EXISTING SWITCHES
AND OTHER DEVICES TO ENSURE UNINTERRUPTED SERVICE. ONCE ALL
EXISTING DATA CIRCUITS ARE RELOCATED TO NEW PATCH PANELS ON THE
NEW RACK AND ALL EXISTING DEVICES TO REMAIN ARE TRANSFERRED TO THE
NEW RACK, REMOVE THE EXISTING RACK AND INSTALL THE NEW RACKS IN THE
FINAL PERMANENT POSITION.
4. PROVIDE NEW VERTICAL WIRE MANAGEMENT SYSTEM, SEE SPECIFICATIONS
FOR ADDITIONAL INFORMATION.
5. EXISTING CABLING CONDUIT AND WIREWAYS ARE TO REMAIN AND BE
CAREFULLY PROTECTED IN PLACE. ALL EXISTING DEVICES ON THE EXISTING
RACK SHALL BE TRANSFERRED TO THE NEW SECOND LEVEL LOCATION ON THE
NEW RACK. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS SHOWING THE
PROPOSED NEW RACK ELEVATION AND PROVIDE A PHASING PLAN FOR
TRANSFERRING ALL EXISTING DEVICES TO REMAIN TO THE NEW RACKS.
6. PROVIDE NEW CABLE TRAY PER REQUIREMENTS LISTED IN CABLE TRAY
SCHEDULE. COORDINATE WITH EXISTING CONDITIONS AND SUBMIT
COORDINATION DRAWINGS FOR REVIEW PRIOR TO COMMENCING WORK.
COORDINATE FIXTURES WITH OVERHEAD TRAY. SEE T-500 SERIES SHEETS FOR
ADDITIONAL REQUIREMENTS. COORDINATE LIGHT FIXTURES WITH OVERHEAD
CABLE TRAY.
7. PROVIDE NEW IP ADDRESSABLE NETWORK CAMERA, POE+, PTZ, MOTION
SENSOR, AUTO-TRACKING, DOME WITH WALL MOUNT. BASIS OF DESIGN
WISENET XNP-6320. MOUNT AT 8’ – 6” A.F.F. TO TOP OF WALL BRACKET.
INTEGRATE CAMERA INTO EXISTING VMS. PROVIDE CONTROLLABILITY THROUGH
EXISTING IT NETWORK.
8. PROVIDE NEW DATA OUTLET, STUB-UP, AND BACK-BOX IN NEW LOCATION IN TR.
9. PROVIDE (2) STACKS OF (3)(6 TOTAL) 4” SPEED CONDUIT SLEEVE THROUGH
WALL ABOVE CEILING GRID FOR HORIZONTAL VOICE/DATA CABLING OR FIBER
WITH PLASTIC BUSHINGS ON BOTH ENDS TO PROTECT CABLES. FIRE CAULK
PENETRATION PER SPECIFICATIONS.
10. EXISTING CONDUIT THROUGH WALL OR FLOOR WITH OPTICAL CABLE TO BE
PROTECTED IN PLACE UNTIL NEW SPEED CONDUIT SLEEVE AND FIBER IS
INSTALLED. DEMOLISH EXISTING CONDUIT ONCE NEW SPEED CONDUIT SLEEVE
AND FIBER ARE OPERATIONAL. CONTRACTOR SHALL PROVIDE A PHASING PLAN
FOR TRANSFERRING FIBER.
11. EXISTING EQUIPMENT TO REMAIN, PROTECT-IN-PLACE.
12. EXISTING WALL MOUNTED FIBER SPLICE WITH MULTI-MODE OPTICAL CABLE TO
BE PROTECTED IN PLACE UNTIL NEW SPEED FIBER IS INSTALLED. DEMOLISH
EXISTING FIBER SPLICE ONCE NEW SPEED CONDUIT SLEEVE AND FIBER ARE
OPERATIONAL. CONTRACTOR SHALL PROVIDE A PHASING PLAN FOR
TRANSFERRING FIBER.
13. REMOVE DATA DEVICE AND RELOCATE, REPLACE CABLING WITH CAT6A MATCH
EXISTING CIRCUIT COUNT. PROVIDE NEW 1-1/4" CONDUIT AS INDICATED ON
T-601.
SCALE: 1" = 10'-0"
F2
TELECOMMUNICATION PLAN - FIRST
LEVEL AREA A
05/06/2022
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
PARTITION RATING GRAPHICS:
2 HR FIRE SHAFT
1 HR SMOKE BARRIER
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION:
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND
SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.
1 HR INCIDENTAL USE
1S-106-C
1S-106-B
1S-106-A
S
-1 -A 1S-107-B
1S-107-C
1S-107-D
1S-112-D
1S-112-A
1S-112-E
1S-112-B
1S-112-C
1S-112-AP-A
1S-100-A
S
-1 -B C1-25-D
C1-25-C
C1-25-B
C -2
-L
C -2
-K
1R-250-H
C1-25A-D
C1-25A-B
C1-25A-B
C1-25A-A
C1-25A-F
C1-25A-E
C1-25A-G
C -2
A
-H
C1-25A-J
C1-24-AP-D
IR-250-AP-A
C1-24-AP-E
C1-186-AP-B
S
-1 -C
C O
A X
1S-105-A 1S-102-A
1S-102-B
C1-192-C
C1-192-B
S
-1 -B
C1-196-AP-C
C1-196-AP-B
C1-196-AP-A
1A-109-AP-A
C1-24-AP-F
1B-102-A
B
-1 -H
B
-1 -G
B
-1 -F
1B-102-E
1B-102-D
1B-102-C
1B-102-B
C1-199-AP-B
C1-199-AP-A
C1-198-AP-B
1A-106-B
1A-106-A
1A-106A-A
A
-1 A
-C
A
-1 A
-B
A
-1 -A
1A-114-A
1A-114-B 1A-113-C
1A-113-B
A
-1 -E
A
-1 -A
A
-1 -C
A
-1 -B
A
-1 -D
1A-110C-B
1A-110C-A 1A-110C-C
1A-110C-D
1A-110C-D
C1-198-AP-A
1A-110-AP-B
1A-110-AP-A
1B-104-AP-A
B
-1 -A
B
-1 -B
1B-105-A
1B-105-B
1A-110C-E
1A-110C-F
NO DATA
NO DATA
NO DATANO DATA NO DATA
NO DATA
NO DATA
NO DATA
N O
D A
T A
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
N O
D A
T A
NO DATA NO DATA
NO DATA
NO DATA NO DATA NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
1S-1251S-125 1S-1271S-1271S-127B1S-127B
1S-121A1S-121A
1S-1211S-121
1R-2501R-250
1S-1281S-128
C1-192C1-192
1S-1121S-112
1S-1001S-100
1S -1
1S
-1
1S-1071S-107
1S-1091S-109
C1-191C1-191
1S-1231S-123
1S-1101S-110
1S-1061S-106
C1-196C1-196
TELECOM
ROOM
1T-1021T-102
C1-195C1-195
ELECTRIC
ROOM
1T-1011T-101 1-S31-S3
C1-197C1-197
1S -1
1S
-1
1S-1041S-104 1S-1031S-103
1S-1021S-102
1S-1011S-101
C1-193C1-193
C1-199C1-199
C1-198C1-198
C1-200C1-200
1A-1051A-105
1A-1091A-109
C1-25C1-25
1A-1041A-104 1A-1061A-106
1A-106A1A-106A
1A-110B1A-110B
1S-51S-5
ELECTRIC
ROOM
1A-1081A-108
1A-1071A-107 1A-1101A-110
1A-110C1A-110C
1A-110A1A-110A
1B-1021B-102
1B-1031B-103
1A-1151A-115
1A-1141A-114
1A-1131A-113
C1-127AC1-127A
1A-1121A-112
C1-27C1-27 1B-1041B-104
1B-1051B-105
C1-127BC1-127B
1A-112A1A-112A
C1-193AC1-193A
AA
1C-1201C-120
DD
1G-1131G-113
1G-1121G-112
1A-111A1A-111A
1G-1091G-109 1G-109B1G-109B
1G-109A1G-109A
1G-105C1G-105C
1G-1011G-101
1G-1021G-102
1G-1041G-104
1G-1031G-103
1G-101C1G-101C
1S-41S-4
ELECTRIC
ROOM
1D-1741D-174
TELECOM
ROOM
1C-1231C-123
C1-202C1-202
1R-1081R-108
1S-1431S-143
1S-1421S-142
1S-1441S-144
1S-1411S-141
1S-1401S-1401S-141A1S-141A
1R-105C1R-105C1R-1061R-106
1R-1031R-103 1R-1041R-104
M-4M-4
1R-105B1R-105B
1R-105A1R-105A
1R-1051R-105
IR-101IR-101
C1-147C1-147
1S-21S-2
1A-1021A-102
1A-1031A-103
M-2M-2
C-10C-10 1A-1011A-101
C-9C-9
C1-194C1-194
C1-194AC1-194A C1-25C1-25
1G-101A1G-101A on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot
REVISIONS DATE
General Notes:
GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO
THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED
BY THE VARIOUS SUBCONTRACTORS.
Approved: Division Chief
Issue Date Checked Drawn
DrawingNumber
Building Number
Project NumberDrawing Title Project Title
Location Drawing Scale
Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs
Office of Construction and Facilities Management
FULLY SPRINKLERED
Phase
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
GENERAL NOTES
KEYNOTES
A
B D
TRUE NORTH
PLAN NORTH
E F
G
H
J
K
L
M
N
C
KEYPLANA/E:
TRIPLE C - The A/E Group
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
As indicated
B
IM
/6
-2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e s M
P L S
V A
M C
/6 -2
-7
.M
E H
R M
.M E
P .B
.L
.r v t
/6
/2
:3 :1
P
M
11/05/2021 M. Perkins G. Weaver
618-21-700
1383 - 70T-101B
TELECOMMUNICATION PLAN - FIRST LEVEL
AREA B
1 Veterans Drive, Minneapolis, MN 55417
B70
EHRM INFRASTRUCTURE
UPGRADESFINAL BID DOCUMENTS
A. PROPERLY FIRE STOP AND SEAL ALL PENETRATIONS THROUGH WALLS,
FLOORS, CEILINGS, AND ROOF AS PER OWNER, CODE, AND AHJ.
B. PRIOR TO INSTALLATION OF CABLE TRAY COORDINATE LOCATIONS WITH ALL
OTHER TRADES AND PROVIDE COORDINATION DRAWINGS FOR REVIEW. ALL
NEW CABLE, CABLE TRAY, J HOOKS SHALL BE INDEPENDENTLY SUPPORTED &
NOT CAUSE ADDITIONAL LOAD ON OTHER SYSTEMS.
C. NOT ALL PARTS AND PIECES ARE SHOWN FOR A COMPLETE SYSTEM.
CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE END-TO-END
WARRANTEED SOLUTION FOR THE CABLING.
D. ALL CABLING TO BE PLENUM RATED THROUGHOUT THE BUILDING.
E. ALL COMMUNICATIONS AND WIRELESS ACCESS POINT CABLING TO MEET OR
EXCEED CATEGORY 6A STANDARDS.
F. SEE E-501 FOR DEVICE STANDARD MOUNTING HEIGHTS.
G. ALL CONDUITS FOR TELECOMMUNICATIONS OUTLETS SHALL BE STEEL THIN
WALL ELECTRICAL METALLIC TUBING (TYPE EMT) UNLESS OTHERWISE NOTED.
UNDER NO CIRCUMSTANCES SHALL FLEXIBLE CONDUIT BE USED FOR
PATHWAYS INDICATED ON THIS DRAWING. ALL CONDUITS ARE TO BE, AT A
MINIMUM, 1-1/4" TRADE SIZE, UNLESS OTHERWISE NOTED. ALL CONDUITS FOR
TELECOMMUNICATIONS OUTLETS ARE TO BE STUBBED TO NEAREST CABLE
TRAY. CONTRACTOR IS TO ENSURE THAT NO CONDUIT EXCEEDS 40% FILL. IF
EXISTING CONDUIT IS NOT LARGE ENOUGH TO SUPPORT NEW CAT 6A CABLE
TO REPLACE ALL EXISTING CIRCUITS ONE-FOR-ONE, CONTRACTOR SHALL
PROVIDE THE MAXIMUM ALLOWABLE NEW CAT 6A CIRCUITS TO REPLACE
EXISTING. THE ADDITIONAL NEW CIRCUITS TO COMPLETE THE ONE-FOR-ONE
REPLACEMENT SHALL BE PROVIDED AT THE NEAREST AVAILABLE DROP WITH
EXISTING CONDUIT CAPACITY.
H. ALL CONDUIT PATHWAYS SHALL BE PROVIDED WITH NYLON BUSHINGS TO
PROTECT CABLES, REGARDLESS OF WHETHER THEY TERMINATE IN A DEVICE
OR JUNCTION BOX.
I. TERMINATE, TEST, LABEL AND DOCUMENT ALL TELECOMMUNICATION CABLES.
J. CONTRACTOR SHALL AVOID ALL SYSTEMS SHUTDOWNS, INSTALL NEW
EQUIPMENT PRIOR TO THE RENOVATION OF EXISTING EQUIPMENT; PROVIDE
TEMPORARY UTILITIES AS REQUIRED TO MEET THIS REQUIREMENT.
K. THE DEMOLITION OF DEVICES SHALL INCLUDE ALL ASSOCIATED CABLING
BACK TO THE RACK.
L. LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL FOLLOWING ALL
STANDARDS AND REQUIREMENTS, SEE DETAIL SHEETS FOR ADDITIONAL
INFORMATION
M. CONTRACTOR SHALL PROVIDE TWO SETS OF LAMINATED FINAL
TELECOMMUNICATION ONE-LINE, RACK ELEVATION, AND CABLE SCHEDULE
DOCUMENTS. HANG ON THE WALL WITHIN THE TELECOM ROOM.
N. REFER TO T-600 SERIES SHEETS FOR PHOTO DOCUMENTATION OF EXISTING
CONDITIONS.
NOTE: NOT ALL KEYNOTES ARE USED
ON EACH SHEET
1. PROVIDE NEW TELECOMMUNICATIONS OUTLET IN EXISTING LOCATION WITH
EXISTING EMT STUB UP TO NEAREST ACCESSIBLE CEILING SPACE. SEE DETAILS
ON SHEET T-501 FOR ADDITIONAL INFORMATION.
2. EXISTING WIRELESS ACCESS POINT TO BE RETAINED AND REUSED. PROVIDE
NEW CABLING AND TELECOMMUNICATIONS OUTLET. REFER TO DETAILS ON
SHEET T-501 FOR ADDITIONAL INFORMATION.
3. PROVIDE NEW 4-POST RACK, PDU, UPS AND WIRE MANAGEMENT COMPONENTS
AS SHOWN ON T-500 SERIES AND T-600 SERIES SHEETS AND IN THE
SPECIFICATIONS. PHASE TO PROVIDE NEW RACK IN A TEMPORARY LOCATION
AND TRANSFER DATA CIRCUITS FROM THE EXISTING RACK TO THE NEW RACK.
PROVIDE TEMPORARY EXTRA LENGTH JUMPER CABLES TO EXISTING SWITCHES
AND OTHER DEVICES TO ENSURE UNINTERRUPTED SERVICE. ONCE ALL
EXISTING DATA CIRCUITS ARE RELOCATED TO NEW PATCH PANELS ON THE
NEW RACK AND ALL EXISTING DEVICES TO REMAIN ARE TRANSFERRED TO THE
NEW RACK, REMOVE THE EXISTING RACK AND INSTALL THE NEW RACKS IN THE
FINAL PERMANENT POSITION.
4. PROVIDE NEW VERTICAL WIRE MANAGEMENT SYSTEM, SEE SPECIFICATIONS
FOR ADDITIONAL INFORMATION.
5. EXISTING CABLING CONDUIT AND WIREWAYS ARE TO REMAIN AND BE
CAREFULLY PROTECTED IN PLACE. ALL EXISTING DEVICES ON THE EXISTING
RACK SHALL BE TRANSFERRED TO THE NEW SECOND LEVEL LOCATION ON THE
NEW RACK. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS SHOWING THE
PROPOSED NEW RACK ELEVATION AND PROVIDE A PHASING PLAN FOR
TRANSFERRING ALL EXISTING DEVICES TO REMAIN TO THE NEW RACKS.
6. PROVIDE NEW CABLE TRAY PER REQUIREMENTS LISTED IN CABLE TRAY
SCHEDULE. COORDINATE WITH EXISTING CONDITIONS AND SUBMIT
COORDINATION DRAWINGS FOR REVIEW PRIOR TO COMMENCING WORK.
COORDINATE FIXTURES WITH OVERHEAD TRAY. SEE T-500 SERIES SHEETS FOR
ADDITIONAL REQUIREMENTS. COORDINATE LIGHT FIXTURES WITH OVERHEAD
CABLE TRAY.
7. PROVIDE NEW IP ADDRESSABLE NETWORK CAMERA, POE+, PTZ, MOTION
SENSOR, AUTO-TRACKING, DOME WITH WALL MOUNT. BASIS OF DESIGN
WISENET XNP-6320. MOUNT AT 8’ – 6” A.F.F. TO TOP OF WALL BRACKET.
INTEGRATE CAMERA INTO EXISTING VMS. PROVIDE CONTROLLABILITY THROUGH
EXISTING IT NETWORK.
8. PROVIDE NEW DATA OUTLET, STUB-UP, AND BACK-BOX IN NEW LOCATION IN TR.
9. PROVIDE (2) STACKS OF (3)(6 TOTAL) 4” SPEED CONDUIT SLEEVE THROUGH
WALL ABOVE CEILING GRID FOR HORIZONTAL VOICE/DATA CABLING OR FIBER
WITH PLASTIC BUSHINGS ON BOTH ENDS TO PROTECT CABLES. FIRE CAULK
PENETRATION PER SPECIFICATIONS.
10. EXISTING CONDUIT THROUGH WALL OR FLOOR WITH OPTICAL CABLE TO BE
PROTECTED IN PLACE UNTIL NEW SPEED CONDUIT SLEEVE AND FIBER IS
INSTALLED. DEMOLISH EXISTING CONDUIT ONCE NEW SPEED CONDUIT SLEEVE
AND FIBER ARE OPERATIONAL. CONTRACTOR SHALL PROVIDE A PHASING PLAN
FOR TRANSFERRING FIBER.
11. EXISTING EQUIPMENT TO REMAIN, PROTECT-IN-PLACE.
12. EXISTING WALL MOUNTED FIBER SPLICE WITH MULTI-MODE OPTICAL CABLE TO
BE PROTECTED IN PLACE UNTIL NEW SPEED FIBER IS INSTALLED. DEMOLISH
EXISTING FIBER SPLICE ONCE NEW SPEED CONDUIT SLEEVE AND FIBER ARE
OPERATIONAL. CONTRACTOR SHALL PROVIDE A PHASING PLAN FOR
TRANSFERRING FIBER.
13. REMOVE DATA DEVICE AND RELOCATE, REPLACE CABLING WITH CAT6A MATCH
EXISTING CIRCUIT COUNT. PROVIDE NEW 1-1/4" CONDUIT AS INDICATED ON
T-601.
SCALE: 1" = 10'-0"
F3
TELECOMMUNICATION PLAN - FIRST
LEVEL AREA B
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
PARTITION RATING GRAPHICS:
2 HR FIRE SHAFT
1 HR SMOKE BARRIER
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION:
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND
SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.
1 HR INCIDENTAL USE
D
-1 -C
D
-1 -A
D
-1 -B
D
-1 -A
D
-1 -B
D
-1 -C
D
-1 -C
D
-1 -B
D
-1 -A
D
-1 -A
D
-1 -B
D
-1 -C
1D-124-AP-A
D
-1 -A
D
-1 -C
D
-1 -B
D
-1 -B
D
-1 -C
D
-1 -A
D
-1 -A
D
-1 -C
D
-1 -B
C1-36-AP-B
C1-34-AP-A
C -3
-A
1U-162B-C1 U
-1 B
-A
D
-1 -C
D
-1 -B
D
-1 -A
1D-118-B
D
-1 -A
D
-1 -A 1D-125-B
1D-113-A
C1-36-AP-C
1D-108-B
1D-108-C
1D-108-A
1D-108-D
D
-1 -A
D
-1 -B
U
-1 -C
U
-1 -A
U
-1 -B
1D-177-C
D
-1 -A
D
-1 -B
1D-115-AP-A
D
-1 -E
D
-1 -D
D
-1 -C
D
-1 -B
D
-1 -A
D
-1 -D
D
-1 -C
D
-1 -A
D
-1 -B
D
-1 -A
D
-1 -D
D
-1 -E
D
-1 -B
D
-1 -C
1D-109-AP-A
1D-109-A
1D-109-B1 D
-1 -C
D
-1 -D
1D-109-E
D
-1 -F
D
-G
D
-1 -H
D
-1 -A
D
-1 -B
D
-1 -C
U
-1 B
-B 1U-162B-AP-A
D
-1 -C
D
-1 -B
D
-1 -A
1D-105-AP-A
D
-1 -C
D
-1 -A
D
-1 -B
D
-1 -C
D
-1 -A
D
-1 -B
D
-1 -B
1D-101-A
D
-1 -A
C1-31-AP-A
C -3
-A
C -3
-B
C -3
-C
C1-31-D
C1-31-E
C1-31-F
1C-104-A
1C-104-B
C1-31-G
C1-31-H
C1-31-AP-B
C1-30-AP-A
D
-1 -A
D
-1 -B
D
-1 -A
D
-1 -A
D
-1 -B
C
-1 -A
C
-1 -B
N O
D A
T A
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
N O
D A
T A
N O
D A
T A
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
70T-412
C3 70T-412
C7
TELECOM
ROOM
(CYAN-STACK)
1C-1061C-106
1U-1621U-162
1U-162A1U-162A
1U-162B1U-162B C1-34AC1-34A
1D-121A1D-121A
1D-1211D-121
1D-1221D-122C1-34C1-34
1D-1171D-117
1D-1151D-115
1D-1141D-114
1D-1161D-116
1D-1181D-118
1D-1231D-123
1D-122A1D-122A1D-115A1D-115A
C1-36C1-36
C1-32C1-32 1D-116A1D-116A
1D-1251D-125
1D-1241D-124
1D-124A1D-124A
1D-125A1D-125A
1D-112A1D-112A
1D-1131D-113
1D-113A1D-113A
1D-1111D-111
1D-1121D-112
1D-1091D-109
C1-38C1-38
1D -1
1D
-1
1D-1261D-126
1D-1271D-127
1D-1301D-130
1D-1321D-132
1D-127A1D-127A
1D-1281D-128
1D-1081D-108
1D-1291D-129
1D-1061D-106 1D-1311D-131
1D-1331D-1331D-135A1D-135A
C1-31C1-31
1D-105A1D-105A 1D-1051D-105
1D-1071D-107
1D-1031D-103
1D-1021D-102
1D-1341D-134
1D-1351D-135
1D-132A1D-132A
1D-134A1D-134A
C1-30C1-30
1D -1
A
1D -1
A
1D-1011D-101
1D-136A1D-136A
1C-1051C-105
1D-102A1D-102A
1D-107A1D-107A
1C-1041C-104
C1-28C1-28 C1-29C1-29
1C-1011C-101
1C-1211C-121
TOILET
1C-1031C-103 C1-37C1-37
C1-40C1-40 on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot
REVISIONS DATE
General Notes:
GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO
THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED
BY THE VARIOUS SUBCONTRACTORS.
Approved: Division Chief
Issue Date Checked Drawn
DrawingNumber
Building Number
Project NumberDrawing Title Project Title
Location Drawing Scale
Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs
Office of Construction and Facilities Management
FULLY SPRINKLERED
Phase
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
GENERAL NOTES
KEYNOTES
A
B D
TRUE NORTH
PLAN NORTH
E F
G
H
J
K
L
M
N
C
KEYPLANA/E:
TRIPLE C - The A/E Group
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
As indicated
B
IM
/6
-2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e s M
P L S
V A
M C
/6 -2
-7
.M
E H
R M
.M E
P .B
.L
.r v t
/6
/2
:3 :2
P
M
11/05/2021 M. Perkins G. Weaver
618-21-700
1383 - 70T-101C
TELECOMMUNICATION PLAN - FIRST LEVEL
AREA C
1 Veterans Drive, Minneapolis, MN 55417
B70
EHRM INFRASTRUCTURE
UPGRADESFINAL BID DOCUMENTS
A. PROPERLY FIRE STOP AND SEAL ALL PENETRATIONS THROUGH WALLS,
FLOORS, CEILINGS, AND ROOF AS PER OWNER, CODE, AND AHJ.
B. PRIOR TO INSTALLATION OF CABLE TRAY COORDINATE LOCATIONS WITH ALL
OTHER TRADES AND PROVIDE COORDINATION DRAWINGS FOR REVIEW. ALL
NEW CABLE, CABLE TRAY, J HOOKS SHALL BE INDEPENDENTLY SUPPORTED &
NOT CAUSE ADDITIONAL LOAD ON OTHER SYSTEMS.
C. NOT ALL PARTS AND PIECES ARE SHOWN FOR A COMPLETE SYSTEM.
CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE END-TO-END
WARRANTEED SOLUTION FOR THE CABLING.
D. ALL CABLING TO BE PLENUM RATED THROUGHOUT THE BUILDING.
E. ALL COMMUNICATIONS AND WIRELESS ACCESS POINT CABLING TO MEET OR
EXCEED CATEGORY 6A STANDARDS.
F. SEE E-501 FOR DEVICE STANDARD MOUNTING HEIGHTS.
G. ALL CONDUITS FOR TELECOMMUNICATIONS OUTLETS SHALL BE STEEL THIN
WALL ELECTRICAL METALLIC TUBING (TYPE EMT) UNLESS OTHERWISE NOTED.
UNDER NO CIRCUMSTANCES SHALL FLEXIBLE CONDUIT BE USED FOR
PATHWAYS INDICATED ON THIS DRAWING. ALL CONDUITS ARE TO BE, AT A
MINIMUM, 1-1/4" TRADE SIZE, UNLESS OTHERWISE NOTED. ALL CONDUITS FOR
TELECOMMUNICATIONS OUTLETS ARE TO BE STUBBED TO NEAREST CABLE
TRAY. CONTRACTOR IS TO ENSURE THAT NO CONDUIT EXCEEDS 40% FILL. IF
EXISTING CONDUIT IS NOT LARGE ENOUGH TO SUPPORT NEW CAT 6A CABLE
TO REPLACE ALL EXISTING CIRCUITS ONE-FOR-ONE, CONTRACTOR SHALL
PROVIDE THE MAXIMUM ALLOWABLE NEW CAT 6A CIRCUITS TO REPLACE
EXISTING. THE ADDITIONAL NEW CIRCUITS TO COMPLETE THE ONE-FOR-ONE
REPLACEMENT SHALL BE PROVIDED AT THE NEAREST AVAILABLE DROP WITH
EXISTING CONDUIT CAPACITY.
H. ALL CONDUIT PATHWAYS SHALL BE PROVIDED WITH NYLON BUSHINGS TO
PROTECT CABLES, REGARDLESS OF WHETHER THEY TERMINATE IN A DEVICE
OR JUNCTION BOX.
I. TERMINATE, TEST, LABEL AND DOCUMENT ALL TELECOMMUNICATION CABLES.
J. CONTRACTOR SHALL AVOID ALL SYSTEMS SHUTDOWNS, INSTALL NEW
EQUIPMENT PRIOR TO THE RENOVATION OF EXISTING EQUIPMENT; PROVIDE
TEMPORARY UTILITIES AS REQUIRED TO MEET THIS REQUIREMENT.
K. THE DEMOLITION OF DEVICES SHALL INCLUDE ALL ASSOCIATED CABLING
BACK TO THE RACK.
L. LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL FOLLOWING ALL
STANDARDS AND REQUIREMENTS, SEE DETAIL SHEETS FOR ADDITIONAL
INFORMATION
M. CONTRACTOR SHALL PROVIDE TWO SETS OF LAMINATED FINAL
TELECOMMUNICATION ONE-LINE, RACK ELEVATION, AND CABLE SCHEDULE
DOCUMENTS. HANG ON THE WALL WITHIN THE TELECOM ROOM.
N. REFER TO T-600 SERIES SHEETS FOR PHOTO DOCUMENTATION OF EXISTING
CONDITIONS.
NOTE: NOT ALL KEYNOTES ARE USED
ON EACH SHEET
1. PROVIDE NEW TELECOMMUNICATIONS OUTLET IN EXISTING LOCATION WITH
EXISTING EMT STUB UP TO NEAREST ACCESSIBLE CEILING SPACE. SEE DETAILS
ON SHEET T-501 FOR ADDITIONAL INFORMATION.
2. EXISTING WIRELESS ACCESS POINT TO BE RETAINED AND REUSED. PROVIDE
NEW CABLING AND TELECOMMUNICATIONS OUTLET. REFER TO DETAILS ON
SHEET T-501 FOR ADDITIONAL INFORMATION.
3. PROVIDE NEW 4-POST RACK, PDU, UPS AND WIRE MANAGEMENT COMPONENTS
AS SHOWN ON T-500 SERIES AND T-600 SERIES SHEETS AND IN THE
SPECIFICATIONS. PHASE TO PROVIDE NEW RACK IN A TEMPORARY LOCATION
AND TRANSFER DATA CIRCUITS FROM THE EXISTING RACK TO THE NEW RACK.
PROVIDE TEMPORARY EXTRA LENGTH JUMPER CABLES TO EXISTING SWITCHES
AND OTHER DEVICES TO ENSURE UNINTERRUPTED SERVICE. ONCE ALL
EXISTING DATA CIRCUITS ARE RELOCATED TO NEW PATCH PANELS ON THE
NEW RACK AND ALL EXISTING DEVICES TO REMAIN ARE TRANSFERRED TO THE
NEW RACK, REMOVE THE EXISTING RACK AND INSTALL THE NEW RACKS IN THE
FINAL PERMANENT POSITION.
4. PROVIDE NEW VERTICAL WIRE MANAGEMENT SYSTEM, SEE SPECIFICATIONS
FOR ADDITIONAL INFORMATION.
5. EXISTING CABLING CONDUIT AND WIREWAYS ARE TO REMAIN AND BE
CAREFULLY PROTECTED IN PLACE. ALL EXISTING DEVICES ON THE EXISTING
RACK SHALL BE TRANSFERRED TO THE NEW SECOND LEVEL LOCATION ON THE
NEW RACK. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS SHOWING THE
PROPOSED NEW RACK ELEVATION AND PROVIDE A PHASING PLAN FOR
TRANSFERRING ALL EXISTING DEVICES TO REMAIN TO THE NEW RACKS.
6. PROVIDE NEW CABLE TRAY PER REQUIREMENTS LISTED IN CABLE TRAY
SCHEDULE. COORDINATE WITH EXISTING CONDITIONS AND SUBMIT
COORDINATION DRAWINGS FOR REVIEW PRIOR TO COMMENCING WORK.
COORDINATE FIXTURES WITH OVERHEAD TRAY. SEE T-500 SERIES SHEETS FOR
ADDITIONAL REQUIREMENTS. COORDINATE LIGHT FIXTURES WITH OVERHEAD
CABLE TRAY.
7. PROVIDE NEW IP ADDRESSABLE NETWORK CAMERA, POE+, PTZ, MOTION
SENSOR, AUTO-TRACKING, DOME WITH WALL MOUNT. BASIS OF DESIGN
WISENET XNP-6320. MOUNT AT 8’ – 6” A.F.F. TO TOP OF WALL BRACKET.
INTEGRATE CAMERA INTO EXISTING VMS. PROVIDE CONTROLLABILITY THROUGH
EXISTING IT NETWORK.
8. PROVIDE NEW DATA OUTLET, STUB-UP, AND BACK-BOX IN NEW LOCATION IN TR.
9. PROVIDE (2) STACKS OF (3)(6 TOTAL) 4” SPEED CONDUIT SLEEVE THROUGH
WALL ABOVE CEILING GRID FOR HORIZONTAL VOICE/DATA CABLING OR FIBER
WITH PLASTIC BUSHINGS ON BOTH ENDS TO PROTECT CABLES. FIRE CAULK
PENETRATION PER SPECIFICATIONS.
10. EXISTING CONDUIT THROUGH WALL OR FLOOR WITH OPTICAL CABLE TO BE
PROTECTED IN PLACE UNTIL NEW SPEED CONDUIT SLEEVE AND FIBER IS
INSTALLED. DEMOLISH EXISTING CONDUIT ONCE NEW SPEED CONDUIT SLEEVE
AND FIBER ARE OPERATIONAL. CONTRACTOR SHALL PROVIDE A PHASING PLAN
FOR TRANSFERRING FIBER.
11. EXISTING EQUIPMENT TO REMAIN, PROTECT-IN-PLACE.
12. EXISTING WALL MOUNTED FIBER SPLICE WITH MULTI-MODE OPTICAL CABLE TO
BE PROTECTED IN PLACE UNTIL NEW SPEED FIBER IS INSTALLED. DEMOLISH
EXISTING FIBER SPLICE ONCE NEW SPEED CONDUIT SLEEVE AND FIBER ARE
OPERATIONAL. CONTRACTOR SHALL PROVIDE A PHASING PLAN FOR
TRANSFERRING FIBER.
13. REMOVE DATA DEVICE AND RELOCATE, REPLACE CABLING WITH CAT6A MATCH
EXISTING CIRCUIT COUNT. PROVIDE NEW 1-1/4" CONDUIT AS INDICATED ON
T-601.
SCALE: 1" = 10'-0"
F6
TELECOMMUNICATION PLAN - FIRST
LEVEL AREA C
WAP
WAP WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
PARTITION RATING GRAPHICS:
2 HR FIRE SHAFT
1 HR SMOKE BARRIER
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION:
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND
SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.
1 HR INCIDENTAL USE
C1-28-AP-A
C1-40-AP-A
C
-1 -A
C
-1 -B
C
-1 -C
1C-106-C
C
-1 -B
C
-1 -A
1C-106-D
1C-107-E
1C-107-D
1C-107-B
C
-1 -B
1C-108-A
C1-49-AP-A
1C-112-A
C1-49-AP-B
1C-115-AP-A
1C-115-A
C1-48-AP-A
C1-38-AP-A
1C-110-C
1C-110-A
C
-1 -B
C
-1 -A
C
-1 -B
1C-135-A
C
-1 -C
C1-39-AP-A
C1-41-C
C1-41-E
C1-41-OC1-41-P
C -4
-M
C -4
-F
C -4
-G
E
-1 -B
1E-104-C
E
-1 -A
C1-41-AP-A
E
-1 A
-A
C1-43-AP-A
C1-43-AP-B
1E-122A-A 1E-119A-B1E-119A-A
C1-46-AP-A
1C-107-C
1C-108-A
C
-1 -A
C
-1 -B
C -4
-L
C -4
-N
C -4
-K
C -4
-J
C -4
-H
C -4
-A
C -4
-B
C1-41-D 1E-104-D
1E-104-A
E
-1 -B
1E-106-C
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATANO DATA
NO DATA NO DATA
NO DATA
NO DATA
NO DATA NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA NO DATA
NO DATA
NO DATA
NO DATA NO DATA NO DATA
NO DATA
NO DATA
NO DATANO DATA
NO DATA
NO DATA
NO DATA
N O
D A
T A
N O
D A
T A
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATANO DATANO DATANO DATANO DATANO DATANO DATA
NO DATA
NO DATA NO DATA NO DATA
NO DATA
70T-412
C3
70T-412
C7
B H
-1 A
-C A
M -0
TELECOM
ROOM
(CYAN-STACK)
1C-1061C-106
SHARED
OFFICE
1C-1071C-107
1D -1
A
1D -1
A
1D-136A1D-136A
1C-1051C-105
1C-1041C-104
C1-50C1-50
1C-1201C-120
C1-49C1-49
DD
1C-1121C-112
M7M7
1C-1151C-115
C1-28C1-28 C1-29C1-29
1C-1011C-101
1C-1211C-121
TOILET
1C-1031C-103
1C-1111C-111
C1-48AC1-48A
C1-37C1-37
1C-1081C-108
C1-48C1-48
1C-1161C-116
1C-1171C-117
1C-1181C-118
1C-1191C-119
1C-114B1C-114B
1C-114D1C-114D
1C-114C1C-114C
1C-114A1C-114A
C1-40C1-40
1E-101A1E-101A
1E-1011E-101 1E-1031E-103 1E-1051E-105
1E-103A1E-103A 1E-105A1E-105A
1E-1071E-107 1E-1101E-110
1E-110A1E-110A
1E-1121E-112 1E-1131E-113 1E-1141E-114
1E-1151E-115
1E-113A1E-113A
1E-115A1E-115A
1E-1161E-116
C1-45C1-45
C1-44C1-44
??1E-1111E-111
1E-111A1E-111A
1E-1091E-109
1E-1231E-123 1E-120A1E-120A
1E-123A1E-123A
C1-43C1-43
C1-42C1-42
C1-46C1-46
TELECOM
ROOM
1E-117C1E-117C
1E-1171E-117
1E-117A1E-117A
ELECTRICAL
ROOM
1E-117B1E-117B
1E-1181E-118
1E-118A1E-118A
1E-1191E-1191E-1211E-121
1E-119A1E-119A
1E-1221E-122
1E-122A1E-122A
1E-1241E-1241E-1251E-125
1E-125A1E-125A
1E-1281E-128
C1-47C1-47
1E-1261E-126
1E-1081E-108
1E-1271E-127
1E-1061E-106
1E -1
1E
-1
1E-1021E-102
1E-1311E-131
C1-41C1-41
1E-1301E-130
1E-130A1E-130A
1E-1321E-132
1E-132A1E-132A
1E-1331E-133
1E-1291E-129
1E-1341E-134
C1-39C1-39
1C-1351C-135
1E-134A1E-134A
1C -1
1C
-1
1F-1361F-136
1F-136A1F-136A
1S-41S-4
ELECTRIC
ROOM
1D-1741D-174
C1-202C1-202
1C-107-A on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot
REVISIONS DATE
General Notes:
GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO
THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED
BY THE VARIOUS SUBCONTRACTORS.
Approved: Division Chief
Issue Date Checked Drawn
DrawingNumber
Building Number
Project NumberDrawing Title Project Title
Location Drawing Scale
Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs
Office of Construction and Facilities Management
FULLY SPRINKLERED
Phase
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
GENERAL NOTES
KEYNOTES
A
B D
TRUE NORTH
PLAN NORTH
E F
G
H
J
K
L
M
N
C
KEYPLANA/E:
TRIPLE C - The A/E Group
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
As indicated
B
IM
/6
-2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e s M
P L S
V A
M C
/6 -2
-7
.M
E H
R M
.M E
P .B
.L
.r v t
/6
/2
:3 :3
P
M
11/05/2021 M. Perkins G. Weaver
618-21-700
1383 - 70T-101D
TELECOMMUNICATION PLAN - FIRST LEVEL
AREA D
1 Veterans Drive, Minneapolis, MN 55417
B70
EHRM INFRASTRUCTURE
UPGRADESFINAL BID DOCUMENTS
A. PROPERLY FIRE STOP AND SEAL ALL PENETRATIONS THROUGH WALLS,
FLOORS, CEILINGS, AND ROOF AS PER OWNER, CODE, AND AHJ.
B. PRIOR TO INSTALLATION OF CABLE TRAY COORDINATE LOCATIONS WITH ALL
OTHER TRADES AND PROVIDE COORDINATION DRAWINGS FOR REVIEW. ALL
NEW CABLE, CABLE TRAY, J HOOKS SHALL BE INDEPENDENTLY SUPPORTED &
NOT CAUSE ADDITIONAL LOAD ON OTHER SYSTEMS.
C. NOT ALL PARTS AND PIECES ARE SHOWN FOR A COMPLETE SYSTEM.
CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE END-TO-END
WARRANTEED SOLUTION FOR THE CABLING.
D. ALL CABLING TO BE PLENUM RATED THROUGHOUT THE BUILDING.
E. ALL COMMUNICATIONS AND WIRELESS ACCESS POINT CABLING TO MEET OR
EXCEED CATEGORY 6A STANDARDS.
F. SEE E-501 FOR DEVICE STANDARD MOUNTING HEIGHTS.
G. ALL CONDUITS FOR TELECOMMUNICATIONS OUTLETS SHALL BE STEEL THIN
WALL ELECTRICAL METALLIC TUBING (TYPE EMT) UNLESS OTHERWISE NOTED.
UNDER NO CIRCUMSTANCES SHALL FLEXIBLE CONDUIT BE USED FOR
PATHWAYS INDICATED ON THIS DRAWING. ALL CONDUITS ARE TO BE, AT A
MINIMUM, 1-1/4" TRADE SIZE, UNLESS OTHERWISE NOTED. ALL CONDUITS FOR
TELECOMMUNICATIONS OUTLETS ARE TO BE STUBBED TO NEAREST CABLE
TRAY. CONTRACTOR IS TO ENSURE THAT NO CONDUIT EXCEEDS 40% FILL. IF
EXISTING CONDUIT IS NOT LARGE ENOUGH TO SUPPORT NEW CAT 6A CABLE
TO REPLACE ALL EXISTING CIRCUITS ONE-FOR-ONE, CONTRACTOR SHALL
PROVIDE THE MAXIMUM ALLOWABLE NEW CAT 6A CIRCUITS TO REPLACE
EXISTING. THE ADDITIONAL NEW CIRCUITS TO COMPLETE THE ONE-FOR-ONE
REPLACEMENT SHALL BE PROVIDED AT THE NEAREST AVAILABLE DROP WITH
EXISTING CONDUIT CAPACITY.
H. ALL CONDUIT PATHWAYS SHALL BE PROVIDED WITH NYLON BUSHINGS TO
PROTECT CABLES, REGARDLESS OF WHETHER THEY TERMINATE IN A DEVICE
OR JUNCTION BOX.
I. TERMINATE, TEST, LABEL AND DOCUMENT ALL TELECOMMUNICATION CABLES.
J. CONTRACTOR SHALL AVOID ALL SYSTEMS SHUTDOWNS, INSTALL NEW
EQUIPMENT PRIOR TO THE RENOVATION OF EXISTING EQUIPMENT; PROVIDE
TEMPORARY UTILITIES AS REQUIRED TO MEET THIS REQUIREMENT.
K. THE DEMOLITION OF DEVICES SHALL INCLUDE ALL ASSOCIATED CABLING
BACK TO THE RACK.
L. LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL FOLLOWING ALL
STANDARDS AND REQUIREMENTS, SEE DETAIL SHEETS FOR ADDITIONAL
INFORMATION
M. CONTRACTOR SHALL PROVIDE TWO SETS OF LAMINATED FINAL
TELECOMMUNICATION ONE-LINE, RACK ELEVATION, AND CABLE SCHEDULE
DOCUMENTS. HANG ON THE WALL WITHIN THE TELECOM ROOM.
N. REFER TO T-600 SERIES SHEETS FOR PHOTO DOCUMENTATION OF EXISTING
CONDITIONS.
NOTE: NOT ALL KEYNOTES ARE USED
ON EACH SHEET
1. PROVIDE NEW TELECOMMUNICATIONS OUTLET IN EXISTING LOCATION WITH
EXISTING EMT STUB UP TO NEAREST ACCESSIBLE CEILING SPACE. SEE DETAILS
ON SHEET T-501 FOR ADDITIONAL INFORMATION.
2. EXISTING WIRELESS ACCESS POINT TO BE RETAINED AND REUSED. PROVIDE
NEW CABLING AND TELECOMMUNICATIONS OUTLET. REFER TO DETAILS ON
SHEET T-501 FOR ADDITIONAL INFORMATION.
3. PROVIDE NEW 4-POST RACK, PDU, UPS AND WIRE MANAGEMENT COMPONENTS
AS SHOWN ON T-500 SERIES AND T-600 SERIES SHEETS AND IN THE
SPECIFICATIONS. PHASE TO PROVIDE NEW RACK IN A TEMPORARY LOCATION
AND TRANSFER DATA CIRCUITS FROM THE EXISTING RACK TO THE NEW RACK.
PROVIDE TEMPORARY EXTRA LENGTH JUMPER CABLES TO EXISTING SWITCHES
AND OTHER DEVICES TO ENSURE UNINTERRUPTED SERVICE. ONCE ALL
EXISTING DATA CIRCUITS ARE RELOCATED TO NEW PATCH PANELS ON THE
NEW RACK AND ALL EXISTING DEVICES TO REMAIN ARE TRANSFERRED TO THE
NEW RACK, REMOVE THE EXISTING RACK AND INSTALL THE NEW RACKS IN THE
FINAL PERMANENT POSITION.
4. PROVIDE NEW VERTICAL WIRE MANAGEMENT SYSTEM, SEE SPECIFICATIONS
FOR ADDITIONAL INFORMATION.
5. EXISTING CABLING CONDUIT AND WIREWAYS ARE TO REMAIN AND BE
CAREFULLY PROTECTED IN PLACE. ALL EXISTING DEVICES ON THE EXISTING
RACK SHALL BE TRANSFERRED TO THE NEW SECOND LEVEL LOCATION ON THE
NEW RACK. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS SHOWING THE
PROPOSED NEW RACK ELEVATION AND PROVIDE A PHASING PLAN FOR
TRANSFERRING ALL EXISTING DEVICES TO REMAIN TO THE NEW RACKS.
6. PROVIDE NEW CABLE TRAY PER REQUIREMENTS LISTED IN CABLE TRAY
SCHEDULE. COORDINATE WITH EXISTING CONDITIONS AND SUBMIT
COORDINATION DRAWINGS FOR REVIEW PRIOR TO COMMENCING WORK.
COORDINATE FIXTURES WITH OVERHEAD TRAY. SEE T-500 SERIES SHEETS FOR
ADDITIONAL REQUIREMENTS. COORDINATE LIGHT FIXTURES WITH OVERHEAD
CABLE TRAY.
7. PROVIDE NEW IP ADDRESSABLE NETWORK CAMERA, POE+, PTZ, MOTION
SENSOR, AUTO-TRACKING, DOME WITH WALL MOUNT. BASIS OF DESIGN
WISENET XNP-6320. MOUNT AT 8’ – 6” A.F.F. TO TOP OF WALL BRACKET.
INTEGRATE CAMERA INTO EXISTING VMS. PROVIDE CONTROLLABILITY THROUGH
EXISTING IT NETWORK.
8. PROVIDE NEW DATA OUTLET, STUB-UP, AND BACK-BOX IN NEW LOCATION IN TR.
9. PROVIDE (2) STACKS OF (3)(6 TOTAL) 4” SPEED CONDUIT SLEEVE THROUGH
WALL ABOVE CEILING GRID FOR HORIZONTAL VOICE/DATA CABLING OR FIBER
WITH PLASTIC BUSHINGS ON BOTH ENDS TO PROTECT CABLES. FIRE CAULK
PENETRATION PER SPECIFICATIONS.
10. EXISTING CONDUIT THROUGH WALL OR FLOOR WITH OPTICAL CABLE TO BE
PROTECTED IN PLACE UNTIL NEW SPEED CONDUIT SLEEVE AND FIBER IS
INSTALLED. DEMOLISH EXISTING CONDUIT ONCE NEW SPEED CONDUIT SLEEVE
AND FIBER ARE OPERATIONAL. CONTRACTOR SHALL PROVIDE A PHASING PLAN
FOR TRANSFERRING FIBER.
11. EXISTING EQUIPMENT TO REMAIN, PROTECT-IN-PLACE.
12. EXISTING WALL MOUNTED FIBER SPLICE WITH MULTI-MODE OPTICAL CABLE TO
BE PROTECTED IN PLACE UNTIL NEW SPEED FIBER IS INSTALLED. DEMOLISH
EXISTING FIBER SPLICE ONCE NEW SPEED CONDUIT SLEEVE AND FIBER ARE
OPERATIONAL. CONTRACTOR SHALL PROVIDE A PHASING PLAN FOR
TRANSFERRING FIBER.
13. REMOVE DATA DEVICE AND RELOCATE, REPLACE CABLING WITH CAT6A MATCH
EXISTING CIRCUIT COUNT. PROVIDE NEW 1-1/4" CONDUIT AS INDICATED ON
T-601.
SCALE: 1" = 10'-0"
F2
TELECOMMUNICATION PLAN - FIRST
LEVEL AREA D
WAP
WAP
WAP
WAP
WAP
WAP WAP
WAP PARTITION RATING GRAPHICS:
2 HR FIRE SHAFT
1 HR SMOKE BARRIER
SMOKE PARTITION (NON RATED)
NON RATED
PARTITION RATING GRAPHIC DESIGNATION:
PARTITIONS REQUIRED TO BE SMOKE RESISTANT, FIRE RESISTANT, OR BOTH FIRE AND
SMOKE RESISTANT ARE SHOWN GRAPHICALLY ON PLANS WITH HATCH PATTERNS.
CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES.
1 HR INCIDENTAL USE
F
-1 -A
F
-1 -A
F
-1 -A
F
-1 -A
F
-1 -A
F
-1 -A
F
-1 -A
F
-1 -A
F
-1 -A
F
-1 -A
F
-1 -E
F
-1 -D
F
-1 -C
F
-1 -F
F
-1 -G
F
-1 -H
1F-120-A
1F-120-B 1F-120A-A
1F-118-B
1F-118-A
C -5
-A
C1-55-AP-A
C1-55A-B
C1-55A-A
1F-122-A
1F-113-AP-A
1F-125-A
C1-54-AP-A
1F-108-D
1F-108-A
1F-108-B
1F-108-C
1F-106-A
F
-1 -B
C -5
-A
C -5
-C
C -5
-D
C1-52-E
C1-52-F
C -5
-G
C -5
-H
C -5
-J
C1-52-AP-C
C -5
-B
C1-52-K
C1-52-M
C1-52-L
C1-52-AP-A
C1-52-AP-B
F
-1 -A
F
-1 -A
F
-1 -A
F
-1 -A
F
-1 -A
F
-1 -A
F
-1 -A
F
-1 -A
F
-1 -A
F
-1 -A
C -5
-A
P -B
C -5
-A
P -C
C1-56-AP-A
NO DATA NO DATA
NO DATA
NO DATA
N O
D A
T A
N O
D A
T A
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
NO DATA
C1-51-AP-B
C1-50C1-50
1C-1201C-120
1C-1151C-115
1C-114D1C-114D
1C-114C1C-114C 1E-1341E-134
1C -1
1C
-1
1F-1361F-136
1F-136A1F-136A
1F-1021F-102 1F-1351F-135
1F-1341F-134
1F-1321F-132
1F-1301F-130
1F-132A1F-132A
1F-134A1F-134A
C1-52C1-52
1F-102A1F-102A
1F-105A1F-105A
1F-1031F-103
1F-1051F-105
1F-1071F-107
1F-1091F-109
1F-1121F-112
1F-107A1F-107A
1F-1041F-1041F-1331F-133
1F-1311F-131
1F-1061F-106
1F-1081F-108 1F-1291F-129
1F-127A1F-127A
1F-1271F-127
1F-1281F-128 1F-1101F-110
C1-54C1-54
1F-1261F-126
C1-55AC1-55A
1F-125A1F-125A
1F-1111F-111
1F-1251F-125
1F-113A1F-113A 1F-112A1F-112A
1F-1141F-114
C1-53C1-53 1F-124A1F-124A
1F-1241F-124
1F-1231F-123
1F-1211F-121
1F-1131F-113
1F-122A1F-122A
1F-121A1F-121A
C1-55C1-55
1F-1151F-115
1F-1161F-116
1F-115A1F-115A
1F-1171F-1171F-117A1F-117A
1F-1181F-118 C1-56C1-561F-120A1F-120A
1F-1201F-120
C1-202C1-202
C1-204C1-204
1L-1161L-116
C1-56AC1-56A
ELECTRIC
ROOM
1F-119A1F-119ATELECOM
ROOM
1F-119B1F-119B
1L-1171L-117
1L-1181L-118
C1-58C1-58
C1-57BC1-57B
STAIRSTAIR
1F-1221F-122 on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot
REVISIONS DATE
General Notes:
GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO
THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED
BY THE VARIOUS SUBCONTRACTORS.
Approved: Division Chief
Issue Date Checked Drawn
DrawingNumber
Building Number
Project NumberDrawing Title Project Title
Location Drawing Scale
Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs
Office of Construction and Facilities Management
FULLY SPRINKLERED
Phase
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
321 4 5 6 7 8 9 10
GENERAL NOTES
KEYNOTES
A
B D
TRUE NORTH
PLAN NORTH
E F
G
H
J
K
L
M
N
C
KEYPLANA/E:
TRIPLE C - The A/E Group
2508 29th Avenue NE
Minneapolis, MN 55418
(612) 355-1251
Mat Perkins
As indicated
B
IM
/6
-2
-7
E
H R
M I n fr a s tr u c tu re U p g ra d e s M
P L S
V A
M C
/6 -2
-7
.M
E H
R M
.M E
P .B
.L
.r v t
/6
/2
:3 :4
P
M
11/05/2021 M. Perkins G. Weaver
618-21-700
1383 - 70T-101E
TELECOMMUNICATION PLAN - FIRST LEVEL
AREA E
1 Veterans Drive, Minneapolis, MN 55417
B70
EHRM INFRASTRUCTURE
UPGRADESFINAL BID DOCUMENTS
A. PROPERLY FIRE STOP AND SEAL ALL PENETRATIONS THROUGH WALLS,
FLOORS, CEILINGS, AND ROOF AS PER OWNER, CODE, AND AHJ.
B. PRIOR TO INSTALLATION OF CABLE TRAY COORDINATE LOCATIONS WITH ALL
OTHER TRADES AND PROVIDE COORDINATION DRAWINGS FOR REVIEW. ALL
NEW CABLE, CABLE TRAY, J HOOKS SHALL BE INDEPENDENTLY SUPPORTED &
NOT CAUSE ADDITIONAL LOAD ON OTHER SYSTEMS.
C. NOT ALL PARTS AND PIECES ARE SHOWN FOR A COMPLETE SYSTEM.
CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE END-TO-END
WARRANTEED SOLUTION FOR THE CABLING.
D. ALL CABLING TO BE PLENUM RATED THROUGHOUT THE BUILDING.
E. ALL COMMUNICATIONS AND WIRELESS ACCESS POINT CABLING TO MEET OR
EXCEED CATEGORY 6A STANDARDS.
F. SEE E-501 FOR DEVICE STANDARD MOUNTING HEIGHTS.
G. ALL CONDUITS FOR TELECOMMUNICATIONS OUTLETS SHALL BE STEEL THIN
WALL ELECTRICAL METALLIC TUBING (TYPE EMT) UNLESS OTHERWISE NOTED.
UNDER NO CIRCUMSTANCES SHALL FLEXIBLE CONDUIT BE USED FOR
PATHWAYS INDICATED ON THIS DRAWING. ALL CONDUITS ARE TO BE, AT A
MINIMUM, 1-1/4" TRADE SIZE, UNLESS OTHERWISE NOTED. ALL CONDUITS FOR
TELECOMMUNICATIONS OUTLETS ARE TO BE STUBBED TO NEAREST CABLE
TRAY. CONTRACTOR IS TO ENSURE THAT NO CONDUIT EXCEEDS 40% FILL. IF
EXISTING CONDUIT IS NOT LARGE ENOUGH TO SUPPORT NEW CAT 6A CABLE
TO REPLACE ALL EXISTING CIRCUITS ONE-FOR-ONE, CONTRACTOR SHALL
PROVIDE THE MAXIMUM ALLOWABLE NEW CAT 6A CIRCUITS TO REPLACE
EXISTING. THE ADDITIONAL NEW CIRCUITS TO COMPLETE THE ONE-FOR-ONE
REPLACEMENT SHALL BE PROVIDED AT THE NEAREST AVAILABLE DROP WITH
EXISTING CONDUIT CAPACITY.
H. ALL CONDUIT PATHWAYS SHALL BE PROVIDED WITH NYLON BUSHINGS TO
PROTECT CABLES, REGARDLESS OF WHETHER THEY TERMINATE IN A DEVICE
OR JUNCTION BOX.
I. TERMINATE, TEST, LABEL AND DOCUMENT ALL TELECOMMUNICATION CABLES.
J. CONTRACTOR SHALL AVOID ALL SYSTEMS SHUTDOWNS, INSTALL NEW
EQUIPMENT PRIOR TO THE RENOVATION OF EXISTING EQUIPMENT; PROVIDE
TEMPORARY UTILITIES AS REQUIRED TO MEET THIS REQUIREMENT.
K. THE DEMOLITION OF DEVICES SHALL INCLUDE ALL ASSOCIATED CABLING
BACK TO THE RACK.
L. LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL FOLLOWING ALL
STANDARDS AND REQUIREMENTS, SEE DETAIL SHEETS FOR ADDITIONAL
INFORMATION
M. CONTRACTOR SHALL PROVIDE TWO SETS OF LAMINATED FINAL
TELECOMMUNICATION ONE-LINE, RACK ELEVATION, AND CABLE SCHEDULE
DOCUMENTS. HANG ON THE WALL WITHIN THE TELECOM ROOM.
N.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .