GC101 - Phasing and Schedule Market Research.pdf
PDF 932 KB Posted
- Solicitation number
- W912DS25RA003
About this file
This document is a Phasing and Schedule Master Research Sketch for the Runway 03-21 Airfield Lighting Repair Project at Wheeler-Sack Army Airfield, Fort Drum, NY. The project is being executed by the U.S. Army Corps of Engineers, with the solicitation number W912-DS-21-D0003 and contract number W912DS23F0103. The site plan details a comprehensive airfield infrastructure renovation, including phased work on runway lighting, communications cable routing, and various airfield components across multiple runways and taxiways.
The project is divided into distinct phases, with specific focus on airfield lighting vault and site work, communications cable installations, and strategic equipment staging areas. The plan includes a contractor batch plant area, multiple construction routes, and carefully mapped out work zones around critical airfield infrastructure such as the Air Traffic Control Tower (ATCT), fire station, and base operations. The issue date is 28 February 2025, with a subsequent revision on 25 April 2025, indicating ongoing planning and refinement of the project details.
View the file
Other files
Show all 49
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
text
H . B
AR
N
H
AR
T
T.
M
O R
R
IS
C . T
W
IG
G
E.
J
AR
G
ER
O
VE
R
AL
L
PH
AS
E
PL
AN
GC101
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
SU
BM
IT
TE
D B
Y:
C H
EC
KE
D B
Y:
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
IS
SU
E D
AT
E:
SI
ZE
M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E
SHEET ID
CUI//FEDCON/NOFORN
CUI//FEDCON/NOFORN
C :\T
EM
P\
PW
_W
O R
K\
ES
T-
LS
\D M
S5
\D
1G
C
1_ G
C
8.
D
W G
3:
:5
PM
/2 5/
H B0
N
EW
Y O
R K
D
IS
TR
IC
T N
EW
Y
O R
K, N
Y
-28 F
EB
. 2
AN
SI
D
W H
EE
LE
R -S
AC
K
AR
M
Y
AI
R
FI
EL
D
, F O
R T
D R
U M
, N Y
R U
N W
AY
3-
A
IR
FI
EL
D L
IG
H
TI
N
G R
EP
AI
R P
R O
JE
C
T W
2-
D S-
-D
W
2D S2
3F
R
TA
S U
BM
IS
SI
O
N
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
RUNWAY 03-21
RUNW
AY 08-26
TW D
TW
G
RU
NW
AY
5-
33 TW
A
TW K
TW
LTW J
SO
UT
H
RA
M P
M O
U N
TAIN
R
AM
P
RUNWAY 03 GLIDE SLOPE
RUNWAY 21
LOCALIZER SHELTER
RUNWAY 21 GLIDE SLOPE
RUNWAY 03 LOCALIZER SHELTER
RUNWAY 03
LOCALIZER
ANTENNA
WSAAF ACP
(RESTRICTED HOURS)
GASOLINE ALLEY ACP
(24 HOUR ACCESS)
NY
S
RO
UT
E
MUNNS CORNERS
ROAD
8TH STREET W
NASH BLVD
TANK TRAIL
O
NTARIO
AVE
LEGEND:
CONTRACTOR TRAILER, EQUIPMENT STAGING AREA
PHASE 1: AIRFIELD LIGHTING VAULT AND SITE
IMPROVEMENTS, DUCTBANK INSTALLATION
OUTSIDE RUNWAY 03-21 VFR HOLD LINES
DUCTBANK INSTALLED VIA HORIZONTAL
DIRECTIONAL DRILLING BENEATH ACTIVE AIRFIELD
PAVEMENT
PRIMARY CONTRACTOR HAUL ROUTE (SEE
GENERAL NOTE 2 ON SHEET GI006)
ALTERNATE CONTRACTOR HAUL ROUTE FOR
NON-AIRFIELD CONCRETE AND ASPHALT
DELIVERIES ONLY (SEE GENERAL NOTE 2 ON SHEET
GI006)
PRIMARY CONTRACTOR HAUL ROUTE FROM
STAGING AREA TO PROJECT LOCATION (SEE
GENERAL NOTE 2 ON SHEET GI006)
PHASE 1 HAUL ROUTE
INSTALLATION OF NEW COMMUNICATIONS CABLE
THROUGH AN EXISTING DUCTBANK
TW B
NORTH RAMP
EXISTING AIRFIELD LIGHTING VAULT
ATCT 892
FIRE STATION
BASE OPS
AIRFIELD GATE
SEE SHEETS ES101 THROUGH
ES105 FOR COMMUNICATIONS
CABLE ROUTING
PLAN
NORTH
0 600' 1200'
1. SEE SHEET GC001 FOR OVERALL WORK RESTRICTION NOTES, PHASING DESCRIPTION
TABLE, DURATIONS AND NOTES FOR WORK INCLUDED IN PHASE 1.
2. SEE SHEETS GC102 THROUGH GC108 FOR ADDITIONAL PHASE 1 DETAIL TO INCLUDE
PLACEMENT LOCATION FOR LOW-PROFILE BARRICADES, FLAGGER LOCATIONS AND
LOCATIONS OF VEHICLE TRACKING PADS.
GENERAL SHEET NOTES:
CONTRACTOR BATCH PLANT AREA
4/
/2
IS
SU
E D
AT
E:
A
PR
. 2 e3cowajm Text Box Machinery, equipment, and material on the airfield are potential flight hazards.
For Phase 1 work, the contractor must move machinery and equipment to a single muster point at the end of each work day during . The exact location can move and is to be coordinated with the airfield during construction. Contractor is responsible for FAA forms.
For Phase 2 work, the contractor will need to stay a minimum of 200 ft from the centerline of the Taxiway J. Work that occurs inside 200 ft from the centerline of TW J needs to be coordinated ahead of time. Contractor does not have to consolidate equipment to a single muster point during Phase 2 work. Contractor must maintain an orderly site.
e3cowajm Rectangle e3cowajm Polygon e3cowajm Callout Phase 1 e3cowajm Callout Phase 2 e3cowajm Dimension e3cowajm Text Box e3cowajm Callout Phase 1 / Phase 2 interface will be 300ft from 03-21.
e3cowajm Arrow e3cowajm Arrow e3cowajm Arrow e3cowajm Arrow e3cowajm Line e3cowajm Text Box e3cowajm Callout Contractor will have access to Gate 16 for 15-33 Phase 1 work.
e3cowajm Ellipse e3cowajm Rectangle e3cowajm Arrow e3cowajm Arrow e3cowajm Arrow e3cowajm Arrow e3cowajm Arrow e3cowajm Arrow e3cowajm Arrow e3cowajm Arrow e3cowajm Arrow e3cowajm Arrow e3cowajm Arrow e3cowajm Arrow e3cowajm Callout Haul Route via Nash Blvd.
e3cowajm Ellipse e3cowajm Ellipse e3cowajm Callout Phase 1 e3cowajm Arrow e3cowajm Arrow e3cowajm Arrow e3cowajm Arrow e3cowajm Arrow e3cowajm Line e3cowajm Callout Gate 13 - Haul Route for dump trucks for 03-21 work.
e3cowajm Arrow e3cowajm Line e3cowajm Callout Gate 2 e3cowajm Ellipse e3cowajm Text Box Tigris River Valley Rd. (8th street will be closed) e3cowajm Line e3cowajm Callout Haul Route via Gas Alley e3cowajm Arrow e3cowajm Arrow e3cowajm Text Box GC101 Phasing and Schedule Market Research Sketch e3cowajm Dimension e3cowajm Arrow e3cowajm Length Measurement 200'-0" e3cowajm Typewritten Text muster point e3cowajm Arrow e3cowajm Length Measurement 300'-0" e3cowajm Callout Haul route via 15-33 will not be available during Phase 2 work.
| GC101 - OVERALL PHASE 1 PLAN |
| GC101 - OVERALL PHASE 1 PLAN |
| GC101 - OVERALL PHASE 1 PLAN |
File details come from the government source that posted it. Updated .